ORU-M Replacement

Table of contents
1 2 Introduction Safety Precautions
2.1 2.1.1 2.1.2 2.2 2.2.1 2.2.2 2.2.3 2.2.4 2.3 Notices for Safety ........................................................................................................................... 2-3 Meanings of Indicators ...................................................................................................................... 2-3 Meanings of Symbols ........................................................................................................................ 2-3 Precautions When Replacing Units............................................................................................... 2-4 Preparation Tasks before Replacing Units ........................................................................................ 2-4 ORU-M Replacement Tasks .............................................................................................................. 2-4 Power Plug......................................................................................................................................... 2-5 Actions in Response to Troubles ....................................................................................................... 2-5 Caution Labels and Indicators....................................................................................................... 2-6

Transfer Belt Cleaning Unit


3.1 3.2 3.3 Prerequisites for Replacing ORU-M Units.................................................................................... 3-3 Replacing ORU-M Units ............................................................................................................... 3-12 Procedure after ORU-M Unit Replacement................................................................................ 3-16

Transfer Belt Unit


4.1 4.2 4.3 Prerequisites for Replacing ORU-M Units.................................................................................... 4-3 Replacing ORU-M Units ............................................................................................................... 4-12 Procedure after ORU-M Unit Replacement................................................................................ 4-13

Fusing Unit
5.1 5.2 5.3 Prerequisites for Replacing ORU-M Units.................................................................................... 5-3 Replacing ORU-M Units ............................................................................................................... 5-11 Procedure after ORU-M Unit Replacement................................................................................ 5-14

Charging Corona
6.1 6.2 6.3 Prerequisites for Replacing ORU-M Units.................................................................................... 6-3 Replacing ORU-M Units ............................................................................................................... 6-12 Procedure after ORU-M Unit Replacement................................................................................ 6-16

Feed Roller Unit (Tray 1, 2)


7.1 7.2 7.3 Prerequisites for Replacing ORU-M Units.................................................................................... 7-3 Replacing ORU-M Units ............................................................................................................... 7-12 Procedure after ORU-M Unit Replacement................................................................................ 7-18

Fusing Cleaning Web


8.1 8.2 8.3 Prerequisites for Replacing ORU-M Units.................................................................................... 8-3 Replacing ORU-M Units ............................................................................................................... 8-11 Procedure after ORU-M Unit Replacement................................................................................ 8-14

bizhub PRESS 1250/1250P/1052

Contents-1

Drum Cleaner
9.1 9.2 9.3 Prerequisites for Replacing ORU-M Units.................................................................................... 9-3 Replacing ORU-M Units ............................................................................................................... 9-12 Procedure after ORU-M Unit Replacement................................................................................ 9-16

10

LPH
10.1 10.2 10.3 Prerequisites for Replacing ORU-M Units.................................................................................. 10-3 Replacing ORU-M Units ............................................................................................................. 10-13 Procedure after ORU-M Unit Replacement.............................................................................. 10-17

11

PCC
11.1 11.2 11.3 Prerequisites for Replacing ORU-M Units.................................................................................. 11-3 Replacing ORU-M Units ............................................................................................................. 11-12 Procedure after ORU-M Unit Replacement.............................................................................. 11-18

12

Developing Suction
12.1 12.2 12.3 Prerequisites for Replacing ORU-M Units.................................................................................. 12-3 Replacing ORU-M Units ............................................................................................................. 12-12 Procedure after ORU-M Unit Replacement.............................................................................. 12-15

Contents-2

bizhub PRESS 1250/1250P/1052

Introduction

Introduction
The Objectives of ORU-M (Operator Replaceable Unit Management)
ORU-M system enables users to replace the machine units by themselves. It also helps to minimize machine downtime.

Notice to users of ORU-M


Make sure you take trainings and obtain a certificate of approval before using the ORU-M. When replacing the machine units, please follow the instructions written in the ORU-M (Operator Replaceable Unit Management) REPLACEMENT INSTRUCTIONS. To perform replacement tasks safely and reliably, keep the ORU-M (Operator Replaceable Unit Management) REPLACEMENT INSTRUCTIONS and do not lose them. If you lose the instructions, contact your service representative.

Registered Trademarks
bizhub PRESS is a trademark of Konica Minolta Business Technologies, Inc. Copyright 2012 Konica Minolta Business Technologies, Inc.

bizhub PRESS 1250/1250P/1052

1-3

1-4

bizhub PRESS 1250/1250P/1052

Safety Precautions

2.1

Notices for Safety

2
2.1

Safety Precautions
Notices for Safety
The followings are what you need to follow to safely replace the units. Please be sure to read the precautions before replacing the units. Keep the ORU-M REPLACEMENT INSTRUCTIONS at hand for your future reference and be careful not to lose it. Make sure you follow the safety precautions listed in the ORU-M REPLACEMENT INSTRUCTIONS.

2.1.1

Meanings of Indicators
The various types of indicators are used as warning in the ORU-M REPLACEMENT INSTRUCTIONS and on the product labels to prevent injury to you and other and damege to property. The table below lists symbols and their meanings. WARNING CAUTION Failure to heed this warning could cause serious injury or even death. Failure to heed this caution could result in injury or damage to property.

2.1.2

Meanings of Symbols
A triangle indicates a danger against which you should take precaution. You can find details of the precautions depicted within into the symbol. (Example) A symbol representing "High Temperature". A diagonal line indicates a prohibited course of action. You can find specific forbidden actions within or near the symbols. (Example) A symbol representing "Prohibition of Disassembly". This symbol indicates an imperative course of action. You can find specific instructions within the symbols. (Example) A symbol meaning "Unplug the Power Cord".

bizhub PRESS 1250/1250P/1052

2-3

2
2.2
2.2.1

Precautions When Replacing Units

2.2

Precautions When Replacing Units


Preparation Tasks before Replacing Units
CAUTION When replacing the units, be sure to receive instructions from our customer engineer, read the ORU-M REPLACEMENT INSTRUCTIONS in entirety and perform tasks in the specified order with appropriate tools. Do not perform any tasks that are not described in the ORU-M REPLACEMENT INSTRUCTIONS. Failure to follow specified order or use appropriate tools could result in injury or physical damage to the product. Please be careful when handling the fusing unit since it can be very hot. It could cause a burn.

2.2.2

ORU-M Replacement Tasks


WARNING Do not drop metal pieces such as clips, staples and screws inside the product or into crevices in it. They could cause a short-circuit in the product, resulting in an electric shock or a fire. Ensure cables are not pinched or damaged. It could cause an electric shock or a fire due to electric leakage. CAUTION Do not place the unit removed in ORU-M tasks on an unstable table or sloped surface, or in a location subject to excessive shocks or vibrations. It could drop or fall and may cause personal injury. Please pay careful attention to the surroundings when placing the unit removed in ORU-M tasks. Protruding portions, cords or wires of the unit may cause falling or personal injury.

2-4

bizhub PRESS 1250/1250P/1052

2.2

Precautions When Replacing Units

2.2.3

Power Plug
WARNING Do not unplug and plug in the power cord with a wet hand, as an electrical shock could result. Plug the power cord all the way into the power outlet. Failure to do this could result in a fire or electrical shock. CAUTION Do not tug the power cord when unplugging. Tugging the cord to do this could damage it, resulting in a fire, electrical shock, or breakdown.

2.2.4

Actions in Response to Troubles


WARNING If it becomes inordinately hot or emits smoke, or an unusual odor or noise, immediately turn off the power switch of the product, and then unplug the power cord from the outlet and contact your authorized service engineer. If the units have been dropped or the covers damaged, immediately turn off the power switch of the product, and then unplug the power cord from the outlet and contact your authorized service engineer. If you continue using it in this condition, a fire or electrical shock could result. CAUTION The inside of this product has areas subject to high temperature, which may cause burns. When inspecting the inside of the product such as when replacing the units, do not touch the locations (around the fusing unit, etc.) which are indicated by a "High Temperature" caution label.

bizhub PRESS 1250/1250P/1052

2-5

2
2.3 Caution Labels and Indicators

Caution Labels and Indicators

2.3

This machine has warning label, caution labels and indicators for safety precaution in the following location. These labels and indicators advise you to pay special attention to avoid any dangerous situations or serious injury when you replace the units.

7 CAUTION
DO NOT remove warning or caution labels! Should any warning or caution label be removed, you may fail to check a specific part to be alert for unexpected trouble or injury. If you find any warning or caution label removed or illegible due to soilage, please contact your service representative.

7 CAUTION
DO NOT touch the fusing part of the fixing conveyance unit. Otherwise, you may get burned. Please be especially careful in withdrawing the fixing conveyance unit or opening the fusing part.

2-6

bizhub PRESS 1250/1250P/1052

2.3

Caution Labels and Indicators

7 CAUTION
DO NOT put your hand or arm between the main body and the fixing conveyance unit. Touching connecting terminals of electric parts may damage the machine or cause unexpected trouble. Please do not try to work yourself, but contact your service representative.

bizhub PRESS 1250/1250P/1052

2-7

2
7 WARNING

Caution Labels and Indicators

2.3

NEVER throw the waste toner box into a fire. Otherwise, the toner may ignite and cause a dangerous situation.

2-8

bizhub PRESS 1250/1250P/1052

Transfer Belt Cleaning Unit

3.1

Prerequisites for Replacing ORU-M Units

Transfer Belt Cleaning Unit


When you want to replace an ORU-M unit, switch the machine to the ORU-M mode and follow the procedures on the screen to replace the unit. This document is comprised of the following sections, in order of screen appearance; Prerequisites for Replacing ORU-M Units explains how to switch the machine to the ORU-M mode and prepare for replacement; Replacing ORU-M Units explains the procedures to replace the ORU-M units; and Procedure after ORU-M Unit Replacement explains the procedures to be performed after replacement. You should print this document out and have the hard copy on hand when you start replacement work.

3.1

Prerequisites for Replacing ORU-M Units


In order to start replacing of ORU-M units, follow the following steps to switch the machine to the ORU-M mode.

Press [Utility/Counter]. The Utility screen is displayed.

Press [ORU-M (Unit Replace)].

The screen to agree on the responsibility for the ORU-M operations is displayed. If the ORU-M password is set, the ORU-M Password screen to enter the password is displayed. Proceed to step 4.

bizhub PRESS 1250/1250P/1052

3-3

3
3
If you agree, press [Yes].

Prerequisites for Replacing ORU-M Units

3.1

If you do not agree, press [No]. The Utility screen will be restored.

The ORU-M Replacement Unit screen is displayed. Proceed to step 5.

Enter 4-digit ORU-M password, and then press [OK]. Use half-width alphanumeric characters for the ORU-M password. The half-width alphanumeric characters used for the passwords are case-sensitive. You cannot use symbols and space character.

NOTICE
The ORU-M password is not set initially. If you want to set the ORU-M password, please contact your service representative. The ORU-M password cannot be modified. If you want to modify it, please contact your service representative.

3-4

bizhub PRESS 1250/1250P/1052

3.1

Prerequisites for Replacing ORU-M Units

Confirm the units that you replace on the ORU-M Replacement Unit screen. On this screen, units to be replaced are listed in the order from the nearest replacement time. The value of life cycle will be greater than or equal to 100% and highlighted in red if the replacement time limit of the unit exceed its life cycle. The date of last replacement is displayed on the right column of the list. If you want to replace the unit now, proceed to step 8.

NOTICE
Initially, all units are displayed regardless of the need for replacement. You can configure it to display only the units needed to be replaced. You can also modify the threshold to decide whether to display the unit to be replaced or not. Please contact your service representative for details.

Display the replacement procedure guide and check the procedures of the unit replacement. You can confirm the unit replacement procedure before you actually replace them. If you do not need to display the replacement procedure guide, proceed to step 7. (1) Press [Replacement Procedure].

The ORU-M Replacement Procedure screen is displayed.

bizhub PRESS 1250/1250P/1052

3-5

3
(2)

Prerequisites for Replacing ORU-M Units

3.1

Press a button of an unit that you want to replace, and then press [Procedure Guide View].

The replacement guide screen is displayed. (3) In order to move to previous or next page of the guide, press [*][)] at the bottom of the guide screen.

(4)

When you confirm the replacement procedure, press the [Close] button twice.

The ORU-M Replacement Unit screen will be restored.

3-6

bizhub PRESS 1250/1250P/1052

3.1

Prerequisites for Replacing ORU-M Units

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 8.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) Press [Close].

The ORU-M Replacement Unit screen will be restored.

bizhub PRESS 1250/1250P/1052

3-7

3
8
Press [Start Replacement].

Prerequisites for Replacing ORU-M Units

3.1

The screen to confirm the ORU-M unit replacemen is displayed.

Remove the fusing unit before replacing the unit.

NOTICE
Do not press [Yes] before removing the fusing unit.

NOTICE
When you want to replace a fusing unit or a unit other than the fusing cleaning web, make sure to remove the fusing unit when this screen is displayed.

3-8

bizhub PRESS 1250/1250P/1052

3.1

Prerequisites for Replacing ORU-M Units

(1)

Open the front door.

(2)

Turn the lever M4 [1] in the direction indicated by the arrow, then pull out the ADU drawer [2].

(3)

Open the reversal output part [1].

(4)

Loosen the lock screw (purple) [1] in the direction (counterclockwise) indicated by the arrow.

(5)

Slide the fusing unit [3] in the direction indicated by the arrow while holding both the front side [1] and the rear side [2] handles, then pull up and remove it. CAUTION Be careful in handling the fusing unit because it may be very hot.

Press [Yes].

bizhub PRESS 1250/1250P/1052

3-9

3
10
Select a unit to replace. Press [Others], then press [OK].

Prerequisites for Replacing ORU-M Units

3.1

% To cancel the replacement, press [Cancel] and put the fusing unit back into place. Press [OK].

NOTICE
For the procedure to set the fusing unit, refer to page 3-16.

3-10

bizhub PRESS 1250/1250P/1052

3.1

Prerequisites for Replacing ORU-M Units

11

A message to notify you that the machine is being switched to the ORU-M mode.

Make sure that the lever M4 is brought down and Tray 1 and Tray 2 are correctly set, then press [Yes].

12

When replacing units, please refer to page 3-12.

NOTICE
You can confirm the replacement procedure by pressing[Replacement Procedure] on the ORU-M Replacement Unit screen and display the replacement procedure guide during the repleacement work. Please refer to step 6 for details.

bizhub PRESS 1250/1250P/1052

3-11

3
3.2 Replacing ORU-M Units
NOTICE

Replacing ORU-M Units

3.2

You can check the procedure of unit replacement on the screen while you are performing the operation.

NOTICE
The replacement of this unit starts with the fusing unit removed. For details on how to remove the fusing unit, refer to page 3-3.

Disconnect the connector [1] of the transfer belt unit.

Lift the transfer belt unit [3] at an angle of 45 degrees holding the areas [1] and [2], then pull in out. Keep the removed transfer belt unit on the flat surface.

Loosen the screws [1] (3 pieces) of ADU drawer cover, then remove the cover.

Disconnect the connectors [1] (2 pieces). Release the connector [2] from the wire saddle.

3-12

bizhub PRESS 1250/1250P/1052

3.2

Replacing ORU-M Units

Remove the black screws [1] (4 pieces).

NOTICE
Be careful not to drop the screws when removing them.

Pull up and remove the relay part.

Remove the transfer belt cleaning unit in the direction indicated by the arrow.

Fix the new transfer belt cleaning unit according the guide pin.

NOTICE
Be careful not to catch the bundled cables when installing the transfer belt cleaning unit.

Insert the relay part to its original position.

bizhub PRESS 1250/1250P/1052

3-13

3
10
Tighten the black screws [1] (4 pieces).

Replacing ORU-M Units

3.2

11

Connect the connectors [1] (2 pieces) so that the blue one is on the left and the white one is on the right. Fix the connector [2] by the wire saddle.

NOTICE
Be careful not to connect a wrong connector.

12

Fix the cover of ADU drawer by tightening the screws [1] (3 pieces).

NOTICE
Be careful not to catch the bundled cables when installing the ADU drawer cover.

13

Insert the transfer belt unit [3] and [4] at an angle of 45 degrees while holding the areas [1] and [2], then set [5] in the direction indicated by the arrow.

NOTICE
Be careful not to catch the bundled cables when installing the transfer belt unit.

3-14

bizhub PRESS 1250/1250P/1052

3.2

Replacing ORU-M Units

14

Connect the connector [1].

bizhub PRESS 1250/1250P/1052

3-15

3
3.3

Procedure after ORU-M Unit Replacement

3.3

Procedure after ORU-M Unit Replacement


When you finished replacing the ORU-M unit, go on to the following operations.

When the replacement is completed, press [Complete Replacement] on the ORU-M Replacement Unit screen.

The power of the machine will be turned on automatically.

NOTICE
You can return to the replacement procedures again and restart the procedures if the [Continue replacement] button is displayed on the screen. Please use this button if you need to replace other units. Once you start the adjustment procedure, the [Continue replacement] button is not displayed on this screen and you cannot return to the replacement procedures.

3-16

bizhub PRESS 1250/1250P/1052

3.3

Procedure after ORU-M Unit Replacement

Install the fusing unit.

(1)

Pull out the ADU drawer and open the reversal output part. Set the fusing unit [3] to the correct position while holding both the front side [1] and the rear side [2] handles. Slide the unit in the direction indicated by the arrow until it reaches the rear side.

(2)

Push the lock screw (purple) [1], then tighten by rotating in the direction indicated by the arrow with a screwdriver.

(3)

Close the reversal output part [1].

bizhub PRESS 1250/1250P/1052

3-17

3
(4)

Procedure after ORU-M Unit Replacement

3.3

Insert the ADU drawer [1], then lock it by lifting the lever M4[2] in the direction indicated by the arrow.

(5)

Close the front door.

Press [Yes].

The Register ORU-M Replacement Unit screen is displayed.

3-18

bizhub PRESS 1250/1250P/1052

3.3

Procedure after ORU-M Unit Replacement

Select the name of the replaced unit. % If you have replaced more than one unit, you can select the ones with the same reason to be registered all at once.

If the [Replace Reason] button is not displayed in the list of the Register ORU-M Replacement Unit screen, press the checkbox next to the [Unit Name].

The checkmark is displayed. Proceed to step 5. % You can select multiple unit names at one time. You can perform subsequent tasks together by selecting all units you replaced.

NOTICE
Only service engineer can configure not to display the [Replace Reason] button on the Register ORUM Replacement Unit screen. Please contact your service representative, if desired.

Press the [Replace Reason] button. The dialog to select a reason to replace is displayed.

bizhub PRESS 1250/1250P/1052

3-19

3
5

Procedure after ORU-M Unit Replacement Select a button for replace reason, then press [OK].

3.3

The replace reason that you selected is displayed in the column of [Replace Reason] button and a checkmark is displayed next to the unit name.

NOTICE
Be sure to select a reason for the replacement. Otherwise, the life cycle counter of the replaced unit will not be reset.

Press [Done].

The dialog box asking to reset the counter of the selected unit is displayed.

3-20

bizhub PRESS 1250/1250P/1052

3.3

Procedure after ORU-M Unit Replacement

Press [Yes].

The life cycle counter of the replaced unit will be reset. % Press [No] to retain the current counter value. The screen to review the life of replace ORU-M units is displayed.

Make sure that the life cycle value of the replaced unit has been cleared.

bizhub PRESS 1250/1250P/1052

3-21

3
9
Print a sample image.

Procedure after ORU-M Unit Replacement

3.3

If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 10.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) (4) Confirm the result of the adjustment by comparing the samples before and after the adjustment. Press [Close].

The ORU-M Replacement Unit screen will be restored.

3-22

bizhub PRESS 1250/1250P/1052

3.3

Procedure after ORU-M Unit Replacement

10

Press [Done].

The Machine Screen will be restored.

bizhub PRESS 1250/1250P/1052

3-23

Procedure after ORU-M Unit Replacement

3.3

3-24

bizhub PRESS 1250/1250P/1052

Transfer Belt Unit

4.1

Prerequisites for Replacing ORU-M Units

Transfer Belt Unit


When you want to replace an ORU-M unit, switch the machine to the ORU-M mode and follow the procedures on the screen to replace the unit. This document is comprised of the following sections, in order of screen appearance; Prerequisites for Replacing ORU-M Units explains how to switch the machine to the ORU-M mode and prepare for replacement; Replacing ORU-M Units explains the procedures to replace the ORU-M units; and Procedure after ORU-M Unit Replacement explains the procedures to be performed after replacement. You should print this document out and have the hard copy on hand when you start replacement work.

4.1

Prerequisites for Replacing ORU-M Units


In order to start replacing of ORU-M units, follow the following steps to switch the machine to the ORU-M mode.

Press [Utility/Counter]. The Utility screen is displayed.

Press [ORU-M (Unit Replace)].

The screen to agree on the responsibility for the ORU-M operations is displayed. If the ORU-M password is set, the ORU-M Password screen to enter the password is displayed. Proceed to step 4.

bizhub PRESS 1250/1250P/1052

4-3

4
3
If you agree, press [Yes].

Prerequisites for Replacing ORU-M Units

4.1

If you do not agree, press [No]. The Utility screen will be restored.

The ORU-M Replacement Unit screen is displayed. Proceed to step 5.

Enter 4-digit ORU-M password, and then press [OK]. Use half-width alphanumeric characters for the ORU-M password. The half-width alphanumeric characters used for the passwords are case-sensitive. You cannot use symbols and space character.

NOTICE
The ORU-M password is not set initially. If you want to set the ORU-M password, please contact your service representative. The ORU-M password cannot be modified. If you want to modify it, please contact your service representative.

4-4

bizhub PRESS 1250/1250P/1052

4.1

Prerequisites for Replacing ORU-M Units

Confirm the units that you replace on the ORU-M Replacement Unit screen. On this screen, units to be replaced are listed in the order from the nearest replacement time. The value of life cycle will be greater than or equal to 100% and highlighted in red if the replacement time limit of the unit exceed its life cycle. The date of last replacement is displayed on the right column of the list. If you want to replace the unit now, proceed to step 8.

NOTICE
Initially, all units are displayed regardless of the need for replacement. You can configure it to display only the units needed to be replaced. You can also modify the threshold to decide whether to display the unit to be replaced or not. Please contact your service representative for details.

Display the replacement procedure guide and check the procedures of the unit replacement. You can confirm the unit replacement procedure before you actually replace them. If you do not need to display the replacement procedure guide, proceed to step 7. (1) Press [Replacement Procedure].

The ORU-M Replacement Procedure screen is displayed.

bizhub PRESS 1250/1250P/1052

4-5

4
(2)

Prerequisites for Replacing ORU-M Units

4.1

Press a button of an unit that you want to replace, and then press [Procedure Guide View].

The replacement guide screen is displayed. (3) In order to move to previous or next page of the guide, press [*][)] at the bottom of the guide screen.

(4)

When you confirm the replacement procedure, press the [Close] button twice.

The ORU-M Replacement Unit screen will be restored.

4-6

bizhub PRESS 1250/1250P/1052

4.1

Prerequisites for Replacing ORU-M Units

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 8.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) Press [Close].

The ORU-M Replacement Unit screen will be restored.

bizhub PRESS 1250/1250P/1052

4-7

4
8
Press [Start Replacement].

Prerequisites for Replacing ORU-M Units

4.1

The screen to confirm the ORU-M unit replacemen is displayed.

Remove the fusing unit before replacing the unit.

NOTICE
Do not press [Yes] before removing the fusing unit.

NOTICE
When you want to replace a fusing unit or a unit other than the fusing cleaning web, make sure to remove the fusing unit when this screen is displayed.

4-8

bizhub PRESS 1250/1250P/1052

4.1

Prerequisites for Replacing ORU-M Units

(1)

Open the front door.

(2)

Turn the lever M4 [1] in the direction indicated by the arrow, then pull out the ADU drawer [2].

(3)

Open the reversal output part [1].

(4)

Loosen the lock screw (purple) [1] in the direction (counterclockwise) indicated by the arrow.

(5)

Slide the fusing unit [3] in the direction indicated by the arrow while holding both the front side [1] and the rear side [2] handles, then pull up and remove it. CAUTION Be careful in handling the fusing unit because it may be very hot.

Press [Yes].

bizhub PRESS 1250/1250P/1052

4-9

4
10
Select a unit to replace. Press [Others], then press [OK].

Prerequisites for Replacing ORU-M Units

4.1

% To cancel the replacement, press [Cancel] and put the fusing unit back into place. Press [OK].

NOTICE
For the procedure to set the fusing unit, refer to page 4-13.

4-10

bizhub PRESS 1250/1250P/1052

4.1

Prerequisites for Replacing ORU-M Units

11

A message to notify you that the machine is being switched to the ORU-M mode.

Make sure that the lever M4 is brought down and Tray 1 and Tray 2 are correctly set, then press [Yes].For details on how to turn down the lever, refer to step (2) on p.2-8.

12

When replacing units, please refer to page 4-12.

NOTICE
You can confirm the replacement procedure by pressing[Replacement Procedure] on the ORU-M Replacement Unit screen and display the replacement procedure guide during the repleacement work. Please refer to step 6 for details.

bizhub PRESS 1250/1250P/1052

4-11

4
4.2 Replacing ORU-M Units
NOTICE

Replacing ORU-M Units

4.2

You can check the procedure of unit replacement on the screen while you are performing the operation.

NOTICE
The replacement of this unit starts with the fusing unit removed. For details on how to remove the fusing unit, refer to page 4-3.

Disconnect the connector [1].

Lift the transfer belt unit [3] at an angle of 45 degrees holding the areas [1] and [2], then pull in out.

Insert the new transfer belt unit [3] and [4] at an angle of 45 degrees while holding the areas [1] and [2], then set [5] in the direction indicated by the arrow.

NOTICE
Be careful not to catch the bundled cables when installing the transfer belt unit.

Connect the connector [1].

4-12

bizhub PRESS 1250/1250P/1052

4.3

Procedure after ORU-M Unit Replacement

4.3

Procedure after ORU-M Unit Replacement


When you finished replacing the ORU-M unit, go on to the following operations.

When the replacement is completed, press [Complete Replacement] on the ORU-M Replacement Unit screen.

The power of the machine will be turned on automatically.

NOTICE
You can return to the replacement procedures again and restart the procedures if the [Continue replacement] button is displayed on the screen. Please use this button if you need to replace other units. Once you start the adjustment procedure, the [Continue replacement] button is not displayed on this screen and you cannot return to the replacement procedures.

bizhub PRESS 1250/1250P/1052

4-13

4
2
Install the fusing unit.

Procedure after ORU-M Unit Replacement

4.3

(1)

Pull out the ADU drawer and open the reversal output part. Set the fusing unit [3] to the correct position while holding both the front side [1] and the rear side [2] handles. Slide the unit in the direction indicated by the arrow until it reaches the rear side.

(2)

Push the lock screw (purple) [1], then tighten by rotating in the direction indicated by the arrow with a screwdriver.

(3)

Close the reversal output part [1].

4-14

bizhub PRESS 1250/1250P/1052

4.3

Procedure after ORU-M Unit Replacement

(4)

Insert the ADU drawer [1], then lock it by lifting the lever M4[2] in the direction indicated by the arrow.

(5)

Close the front door.

Press [Yes].

The Register ORU-M Replacement Unit screen is displayed.

bizhub PRESS 1250/1250P/1052

4-15

4
3
Select the name of the replaced unit.

Procedure after ORU-M Unit Replacement

4.3

% If you have replaced more than one unit, you can select the ones with the same reason to be registered all at once.

If the [Replace Reason] button is not displayed in the list of the Register ORU-M Replacement Unit screen, press the checkbox next to the [Unit Name].

The checkmark is displayed. Proceed to step 5. % You can select multiple unit names at one time. You can perform subsequent tasks together by selecting all units you replaced.

NOTICE
Only service engineer can configure not to display the [Replace Reason] button on the Register ORUM Replacement Unit screen. Please contact your service representative, if desired.

Press the [Replace Reason] button. The dialog to select a reason to replace is displayed.

4-16

bizhub PRESS 1250/1250P/1052

4.3

Procedure after ORU-M Unit Replacement

Select a button for replace reason, then press [OK].

The replace reason that you selected is displayed in the column of [Replace Reason] button and a checkmark is displayed next to the unit name.

NOTICE
Be sure to select a reason for the replacement. Otherwise, the life cycle counter of the replaced unit will not be reset.

Press [Done].

The dialog box asking to reset the counter of the selected unit is displayed.

bizhub PRESS 1250/1250P/1052

4-17

4
7
Press [Yes].

Procedure after ORU-M Unit Replacement

4.3

The life cycle counter of the replaced unit will be reset. % Press [No] to retain the current counter value. The screen to review the life of replace ORU-M units is displayed.

Make sure that the life cycle value of the replaced unit has been cleared.

4-18

bizhub PRESS 1250/1250P/1052

4.3

Procedure after ORU-M Unit Replacement

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 10.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) (4) Confirm the result of the adjustment by comparing the samples before and after the adjustment. Press [Close].

The ORU-M Replacement Unit screen will be restored.

bizhub PRESS 1250/1250P/1052

4-19

4
10
Press [Done].

Procedure after ORU-M Unit Replacement

4.3

The Machine Screen will be restored.

4-20

bizhub PRESS 1250/1250P/1052

Fusing Unit

5.1

Prerequisites for Replacing ORU-M Units

Fusing Unit
When you want to replace an ORU-M unit, switch the machine to the ORU-M mode and follow the procedures on the screen to replace the unit. This document is comprised of the following sections, in order of screen appearance; Prerequisites for Replacing ORU-M Units explains how to switch the machine to the ORU-M mode and prepare for replacement; Replacing ORU-M Units explains the procedures to replace the ORU-M units; and Procedure after ORU-M Unit Replacement explains the procedures to be performed after replacement. You should print this document out and have the hard copy on hand when you start replacement work.

5.1

Prerequisites for Replacing ORU-M Units


In order to start replacing of ORU-M units, follow the following steps to switch the machine to the ORU-M mode.

Press [Utility/Counter]. The Utility screen is displayed.

Press [ORU-M (Unit Replace)].

The screen to agree on the responsibility for the ORU-M operations is displayed. If the ORU-M password is set, the ORU-M Password screen to enter the password is displayed. Proceed to step 4.

bizhub PRESS 1250/1250P/1052

5-3

5
3
If you agree, press [Yes].

Prerequisites for Replacing ORU-M Units

5.1

If you do not agree, press [No]. The Utility screen will be restored.

The ORU-M Replacement Unit screen is displayed. Proceed to step 5.

Enter 4-digit ORU-M password, and then press [OK]. Use half-width alphanumeric characters for the ORU-M password. The half-width alphanumeric characters used for the passwords are case-sensitive. You cannot use symbols and space character.

NOTICE
The ORU-M password is not set initially. If you want to set the ORU-M password, please contact your service representative. The ORU-M password cannot be modified. If you want to modify it, please contact your service representative.

5-4

bizhub PRESS 1250/1250P/1052

5.1

Prerequisites for Replacing ORU-M Units

Confirm the units that you replace on the ORU-M Replacement Unit screen. On this screen, units to be replaced are listed in the order from the nearest replacement time. The value of life cycle will be greater than or equal to 100% and highlighted in red if the replacement time limit of the unit exceed its life cycle. The date of last replacement is displayed on the right column of the list. If you want to replace the unit now, proceed to step 8.

NOTICE
Initially, all units are displayed regardless of the need for replacement. You can configure it to display only the units needed to be replaced. You can also modify the threshold to decide whether to display the unit to be replaced or not. Please contact your service representative for details.

Display the replacement procedure guide and check the procedures of the unit replacement. You can confirm the unit replacement procedure before you actually replace them. If you do not need to display the replacement procedure guide, proceed to step 7. (1) Press [Replacement Procedure].

The ORU-M Replacement Procedure screen is displayed.

bizhub PRESS 1250/1250P/1052

5-5

5
(2)

Prerequisites for Replacing ORU-M Units

5.1

Press a button of an unit that you want to replace, and then press [Procedure Guide View].

The replacement guide screen is displayed. (3) In order to move to previous or next page of the guide, press [*][)] at the bottom of the guide screen.

(4)

When you confirm the replacement procedure, press the [Close] button twice.

The ORU-M Replacement Unit screen will be restored.

5-6

bizhub PRESS 1250/1250P/1052

5.1

Prerequisites for Replacing ORU-M Units

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 8.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) Press [Close].

The ORU-M Replacement Unit screen will be restored.

bizhub PRESS 1250/1250P/1052

5-7

5
8
Press [Start Replacement].

Prerequisites for Replacing ORU-M Units

5.1

The screen to confirm the ORU-M unit replacemen is displayed.

Press [Yes].

5-8

bizhub PRESS 1250/1250P/1052

5.1

Prerequisites for Replacing ORU-M Units

10

Select a unit to replace. Press [Others], then press [OK].

% To stop the replacement operation, press [Cancel].

11

A message to notify you that the machine is being switched to the ORU-M mode.

Make sure that the lever M4 is brought down and Tray 1 and Tray 2 are correctly set, then press [Yes].

bizhub PRESS 1250/1250P/1052

5-9

5
12
When replacing units, please refer to page 5-11.

Prerequisites for Replacing ORU-M Units

5.1

NOTICE
You can confirm the replacement procedure by pressing[Replacement Procedure] on the ORU-M Replacement Unit screen and display the replacement procedure guide during the repleacement work. Please refer to step 6 for details.

5-10

bizhub PRESS 1250/1250P/1052

5.2

Replacing ORU-M Units

5.2

Replacing ORU-M Units


NOTICE
You can check the procedure of unit replacement on the screen while you are performing the operation.

Open the front door.

Turn the lever M4[1] in the direction indicated by the arrow, then pull out the ADU drawer [2].

Open the reversal output part [1].

Loosen the lock screw (purple) [1] in the direction indicated by the arrow.

bizhub PRESS 1250/1250P/1052

5-11

5
5
Slide the fusing unit [3] in the direction indicated by the arrow while holding both the front side [1] and the rear side [2] handles, then pull up and remove it. CAUTION Be careful in handling the fusing unit because it may be very hot.

Replacing ORU-M Units

5.2

Hold both the front side [1] and the rear side [2] handles and set the new fusing unit [3] to the correct position. Slide the unit in the direction indicated by the arrow until it reaches the rear side.

Push the lock screw (purple) [1], then tighten by rotating in the direction indicated by the arrow with a screwdriver.

Close the reversal output part [1].

Insert the ADU drawer [1], then lock it by lifting the lever M4[2] in the direction indicated by the arrow.

5-12

bizhub PRESS 1250/1250P/1052

5.2

Replacing ORU-M Units

10

Close the front door.

bizhub PRESS 1250/1250P/1052

5-13

5
5.3

Procedure after ORU-M Unit Replacement

5.3

Procedure after ORU-M Unit Replacement


When you finished replacing the ORU-M unit, go on to the following operations.

When the replacement is completed, press [Complete Replacement] on the ORU-M Replacement Unit screen.

The power of the machine will be turned on automatically.

NOTICE
You can return to the replacement procedures again and restart the procedures if the [Continue replacement] button is displayed on the screen. Please use this button if you need to replace other units. Once you start the adjustment procedure, the [Continue replacement] button is not displayed on this screen and you cannot return to the replacement procedures.
The Register ORU-M Replacement Unit screen is displayed.

5-14

bizhub PRESS 1250/1250P/1052

5.3

Procedure after ORU-M Unit Replacement

Select the name of the replaced unit. % If you have replaced more than one unit, you can select the ones with the same reason to be registered all at once.

If the [Replace Reason] button is not displayed in the list of the Register ORU-M Replacement Unit screen, press the checkbox next to the [Unit Name].

The checkmark is displayed. Proceed to step 5. % You can select multiple unit names at one time. You can perform subsequent tasks together by selecting all units you replaced.

NOTICE
Only service engineer can configure not to display the [Replace Reason] button on the Register ORUM Replacement Unit screen. Please contact your service representative, if desired.

Press the [Replace Reason] button. The dialog to select a reason to replace is displayed.

bizhub PRESS 1250/1250P/1052

5-15

5
4

Procedure after ORU-M Unit Replacement Select a button for replace reason, then press [OK].

5.3

The replace reason that you selected is displayed in the column of [Replace Reason] button and a checkmark is displayed next to the unit name.

NOTICE
Be sure to select a reason for the replacement. Otherwise, the life cycle counter of the replaced unit will not be reset.

Press [Done].

The dialog box asking to reset the counter of the selected unit is displayed.

5-16

bizhub PRESS 1250/1250P/1052

5.3

Procedure after ORU-M Unit Replacement

Press [Yes].

The life cycle counter of the replaced unit will be reset. % Press [No] to retain the current counter value. The screen to review the life of replace ORU-M units is displayed.

Make sure that the life cycle value of the replaced unit has been cleared.

bizhub PRESS 1250/1250P/1052

5-17

5
8
Print a sample image.

Procedure after ORU-M Unit Replacement

5.3

If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 10.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) (4) Confirm the result of the adjustment by comparing the samples before and after the adjustment. Press [Close].

The ORU-M Replacement Unit screen will be restored.

5-18

bizhub PRESS 1250/1250P/1052

5.3

Procedure after ORU-M Unit Replacement

Press [Done].

The Machine Screen will be restored.

bizhub PRESS 1250/1250P/1052

5-19

Procedure after ORU-M Unit Replacement

5.3

5-20

bizhub PRESS 1250/1250P/1052

Charging Corona

6.1

Prerequisites for Replacing ORU-M Units

Charging Corona
When you want to replace an ORU-M unit, switch the machine to the ORU-M mode and follow the procedures on the screen to replace the unit. This document is comprised of the following sections, in order of screen appearance; Prerequisites for Replacing ORU-M Units explains how to switch the machine to the ORU-M mode and prepare for replacement; Replacing ORU-M Units explains the procedures to replace the ORU-M units; and Procedure after ORU-M Unit Replacement explains the procedures to be performed after replacement. You should print this document out and have the hard copy on hand when you start replacement work.

6.1

Prerequisites for Replacing ORU-M Units


In order to start replacing of ORU-M units, follow the following steps to switch the machine to the ORU-M mode.

Press [Utility/Counter]. The Utility screen is displayed.

Press [ORU-M (Unit Replace)].

The screen to agree on the responsibility for the ORU-M operations is displayed. If the ORU-M password is set, the ORU-M Password screen to enter the password is displayed. Proceed to step 4.

bizhub PRESS 1250/1250P/1052

6-3

6
3
If you agree, press [Yes].

Prerequisites for Replacing ORU-M Units

6.1

If you do not agree, press [No]. The Utility screen will be restored.

The ORU-M Replacement Unit screen is displayed. Proceed to step 5.

Enter 4-digit ORU-M password, and then press [OK]. Use half-width alphanumeric characters for the ORU-M password. The half-width alphanumeric characters used for the passwords are case-sensitive. You cannot use symbols and space character.

NOTICE
The ORU-M password is not set initially. If you want to set the ORU-M password, please contact your service representative. The ORU-M password cannot be modified. If you want to modify it, please contact your service representative.

6-4

bizhub PRESS 1250/1250P/1052

6.1

Prerequisites for Replacing ORU-M Units

Confirm the units that you replace on the ORU-M Replacement Unit screen. On this screen, units to be replaced are listed in the order from the nearest replacement time. The value of life cycle will be greater than or equal to 100% and highlighted in red if the replacement time limit of the unit exceed its life cycle. The date of last replacement is displayed on the right column of the list. If you want to replace the unit now, proceed to step 8.

NOTICE
Initially, all units are displayed regardless of the need for replacement. You can configure it to display only the units needed to be replaced. You can also modify the threshold to decide whether to display the unit to be replaced or not. Please contact your service representative for details.

Display the replacement procedure guide and check the procedures of the unit replacement. You can confirm the unit replacement procedure before you actually replace them. If you do not need to display the replacement procedure guide, proceed to step 7. (1) Press [Replacement Procedure].

The ORU-M Replacement Procedure screen is displayed.

bizhub PRESS 1250/1250P/1052

6-5

6
(2)

Prerequisites for Replacing ORU-M Units

6.1

Press a button of an unit that you want to replace, and then press [Procedure Guide View].

The replacement guide screen is displayed. (3) In order to move to previous or next page of the guide, press [*][)] at the bottom of the guide screen.

(4)

When you confirm the replacement procedure, press the [Close] button twice.

The ORU-M Replacement Unit screen will be restored.

6-6

bizhub PRESS 1250/1250P/1052

6.1

Prerequisites for Replacing ORU-M Units

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 8.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) Press [Close].

The ORU-M Replacement Unit screen will be restored.

bizhub PRESS 1250/1250P/1052

6-7

6
8
Press [Start Replacement].

Prerequisites for Replacing ORU-M Units

6.1

The screen to confirm the ORU-M unit replacemen is displayed.

Remove the fusing unit before replacing the unit.

NOTICE
Do not press [Yes] before removing the fusing unit.

NOTICE
When you want to replace a fusing unit or a unit other than the fusing cleaning web, make sure to remove the fusing unit when this screen is displayed.

6-8

bizhub PRESS 1250/1250P/1052

6.1

Prerequisites for Replacing ORU-M Units

(1)

Open the front door.

(2)

Turn the lever M4 [1] in the direction indicated by the arrow, then pull out the ADU drawer [2].

(3)

Open the reversal output part [1].

(4)

Loosen the lock screw (purple) [1] in the direction (counterclockwise) indicated by the arrow.

(5)

Slide the fusing unit [3] in the direction indicated by the arrow while holding both the front side [1] and the rear side [2] handles, then pull up and remove it. CAUTION Be careful in handling the fusing unit because it may be very hot.

bizhub PRESS 1250/1250P/1052

6-9

6
(6)

Prerequisites for Replacing ORU-M Units

6.1

Close the reversal output part and put the ADU drawer back into place.

NOTICE
Please make sure not lift the lever M4 after returning the ADU drawer to its original position.
Press [Yes].

10

Select a unit to replace. Press [Others], then press [OK].

% To cancel the replacement, press [Cancel] and put the fusing unit back into place. Press [OK].

NOTICE
For the procedure to set the fusing unit, refer to page 6-16.

6-10

bizhub PRESS 1250/1250P/1052

6.1

Prerequisites for Replacing ORU-M Units

11

A message to notify you that the machine is being switched to the ORU-M mode.

Make sure that the lever M4 is brought down and Tray 1 and Tray 2 are correctly set, then press [Yes].For details on how to turn down the lever, refer to step (2) on p.2-8.

12

When replacing units, please refer to page 6-12.

NOTICE
You can confirm the replacement procedure by pressing[Replacement Procedure] on the ORU-M Replacement Unit screen and display the replacement procedure guide during the repleacement work. Please refer to step 6 for details.

bizhub PRESS 1250/1250P/1052

6-11

6
6.2 Replacing ORU-M Units
NOTICE

Replacing ORU-M Units

6.2

You can check the procedure of unit replacement on the screen while you are performing the operation.

NOTICE
The replacement of this unit starts with the fusing unit removed. For details on how to remove the fusing unit, refer to page 6-3.

Loosen the screws [1] (2 pieces), then remove the cover of the drum part [2].

Release the lock [1] and pull out the intermediate toner hopper, then release the lock [2] and open in the direction indicated by the arrow.

Disconnect the LPH connectors [1] (2 pieces).

Slowly rotate the drum lock knob [1] clockwise [2] more than one revolution in order to remove the toner on the drum. Then, firmly rotate the drum lock knob counterclockwise [3] to remove it[1].

6-12

bizhub PRESS 1250/1250P/1052

6.2

Replacing ORU-M Units

Turn the left [1] and right [2] lock levers in the direction indicated by the arrow, then pull out the drum part to the front.

Release the wire saddle [1], and disconnect the connectors [2] (2 pieces).

Remove the charging corona unit [3] while holding the areas [1] and [2].

Hold the areas [1] and [2] of the new charging corona unit [3], then align it into the fitting to install it by fitting and pushing the areas [1] and [2].

NOTICE
Be careful not to catch the bundled cables when installing the charging corona unit.

Connect the connectors [1] (2 pieces) and fasten the wire saddle [2].

NOTICE
Do not forget to connect the connectors of the charging corona.

bizhub PRESS 1250/1250P/1052

6-13

6
10
Insert the drum part [3] with holding the drum lock levers [1][2], then lock the drum lock levers [1][2] by rotating them in the direction indicated by the arrow.

Replacing ORU-M Units

6.2

11

Fix the drum lock knob [1], and tighten it by rotating clockwise.

NOTICE
If the coupling of the drum is sticking out to the front, make sure to push it back in.

12

Connect the LPH connectors [1] (2 pieces).

NOTICE
Do not forget to connect the LPH connectors.

13

Return the intermediate toner hopper [1] to its original position. Set the lock levers [2][3].

NOTICE
Push the PUSH mark on the intermediate toner hopper firmly until it makes a clicking noise and confirm it is locked.

6-14

bizhub PRESS 1250/1250P/1052

6.2

Replacing ORU-M Units

14

Fix the cover of the drum part [1], then tighten the screws [2] (2 pieces) on the right first then the left

bizhub PRESS 1250/1250P/1052

6-15

6
6.3

Procedure after ORU-M Unit Replacement

6.3

Procedure after ORU-M Unit Replacement


When you finished replacing the ORU-M unit, go on to the following operations.

When the replacement is completed, press [Complete Replacement] on the ORU-M Replacement Unit screen.

The power of the machine will be turned on automatically.

NOTICE
You can return to the replacement procedures again and restart the procedures if the [Continue replacement] button is displayed on the screen. Please use this button if you need to replace other units. Once you start the adjustment procedure, the [Continue replacement] button is not displayed on this screen and you cannot return to the replacement procedures.

6-16

bizhub PRESS 1250/1250P/1052

6.3

Procedure after ORU-M Unit Replacement

Install the fusing unit.

(1)

Pull out the ADU drawer and open the reversal output part. Set the fusing unit [3] to the correct position while holding both the front side [1] and the rear side [2] handles. Slide the unit in the direction indicated by the arrow until it reaches the rear side.

(2)

Push the lock screw (purple) [1], then tighten by rotating in the direction indicated by the arrow with a screwdriver.

(3)

Close the reversal output part [1].

bizhub PRESS 1250/1250P/1052

6-17

6
(4)

Procedure after ORU-M Unit Replacement

6.3

Insert the ADU drawer [1], then lock it by lifting the lever M4[2] in the direction indicated by the arrow.

(5)

Close the front door.

Press [Yes].

NOTICE
If a connector of the charging corona or LPH is not connected after the charging corona is replaced, the Detected disengagement of connector screen will be displayed.

6-18

bizhub PRESS 1250/1250P/1052

6.3

Procedure after ORU-M Unit Replacement

(1)

Open the front door, turn the lever M4 down, then press [OK].

The screen notifying you of ORU-M connector disengagement. (2) Press [NG] of the Status field for the disconnected connector.

A detailed screen to show the place of the disconnected connector will be displayed.

bizhub PRESS 1250/1250P/1052

6-19

6
(3)

Procedure after ORU-M Unit Replacement

6.3

Refer to page 6-12 and connect the appropriate connector.

Press [Close] on the sub-screen (4) (5) (6) Lift the lever M4 to lock. Close the front door. Press [Close].

The Register ORU-M Replacement Unit screen is displayed.

Select the name of the replaced unit. % If you have replaced more than one unit, you can select the ones with the same reason to be registered all at once.

6-20

bizhub PRESS 1250/1250P/1052

6.3

Procedure after ORU-M Unit Replacement If the [Replace Reason] button is not displayed in the list of the Register ORU-M Replacement Unit screen, press the checkbox next to the [Unit Name].

The checkmark is displayed. Proceed to step 5. % You can select multiple unit names at one time. You can perform subsequent tasks together by selecting all units you replaced.

NOTICE
Only service engineer can configure not to display the [Replace Reason] button on the Register ORUM Replacement Unit screen. Please contact your service representative, if desired.

4 5

Press the [Replace Reason] button. The dialog to select a reason to replace is displayed. Select a button for replace reason, then press [OK].

The replace reason that you selected is displayed in the column of [Replace Reason] button and a checkmark is displayed next to the unit name.

bizhub PRESS 1250/1250P/1052

6-21

6
NOTICE

Procedure after ORU-M Unit Replacement

6.3

Be sure to select a reason for the replacement. Otherwise, the life cycle counter of the replaced unit will not be reset.

Press [Done].

The dialog box asking to reset the counter of the selected unit is displayed.

Press [Yes].

The life cycle counter of the replaced unit will be reset. % Press [No] to retain the current counter value. The screen to review the life of replace ORU-M units is displayed.

6-22

bizhub PRESS 1250/1250P/1052

6.3

Procedure after ORU-M Unit Replacement

Make sure that the life cycle value of the replaced unit has been cleared.

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 10.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed.

bizhub PRESS 1250/1250P/1052

6-23

6
(2)

Procedure after ORU-M Unit Replacement

6.3

Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) (4) Confirm the result of the adjustment by comparing the samples before and after the adjustment. Press [Close].

The ORU-M Replacement Unit screen will be restored.

10

Press [Done].

The Machine Screen will be restored.

6-24

bizhub PRESS 1250/1250P/1052

Feed Roller Unit (Tray 1, 2)

7.1

Prerequisites for Replacing ORU-M Units

Feed Roller Unit (Tray 1, 2)


When you want to replace an ORU-M unit, switch the machine to the ORU-M mode and follow the procedures on the screen to replace the unit. This document is comprised of the following sections, in order of screen appearance; Prerequisites for Replacing ORU-M Units explains how to switch the machine to the ORU-M mode and prepare for replacement; Replacing ORU-M Units explains the procedures to replace the ORU-M units; and Procedure after ORU-M Unit Replacement explains the procedures to be performed after replacement. You should print this document out and have the hard copy on hand when you start replacement work.

7.1

Prerequisites for Replacing ORU-M Units


In order to start replacing of ORU-M units, follow the following steps to switch the machine to the ORU-M mode.

Press [Utility/Counter]. The Utility screen is displayed.

Press [ORU-M (Unit Replace)].

The screen to agree on the responsibility for the ORU-M operations is displayed. If the ORU-M password is set, the ORU-M Password screen to enter the password is displayed. Proceed to step 4.

bizhub PRESS 1250/1250P/1052

7-3

7
3
If you agree, press [Yes].

Prerequisites for Replacing ORU-M Units

7.1

If you do not agree, press [No]. The Utility screen will be restored.

The ORU-M Replacement Unit screen is displayed. Proceed to step 5.

Enter 4-digit ORU-M password, and then press [OK]. Use half-width alphanumeric characters for the ORU-M password. The half-width alphanumeric characters used for the passwords are case-sensitive. You cannot use symbols and space character.

NOTICE
The ORU-M password is not set initially. If you want to set the ORU-M password, please contact your service representative. The ORU-M password cannot be modified. If you want to modify it, please contact your service representative.

7-4

bizhub PRESS 1250/1250P/1052

7.1

Prerequisites for Replacing ORU-M Units

Confirm the units that you replace on the ORU-M Replacement Unit screen. On this screen, units to be replaced are listed in the order from the nearest replacement time. The value of life cycle will be greater than or equal to 100% and highlighted in red if the replacement time limit of the unit exceed its life cycle. The date of last replacement is displayed on the right column of the list. If you want to replace the unit now, proceed to step 8.

NOTICE
Initially, all units are displayed regardless of the need for replacement. You can configure it to display only the units needed to be replaced. You can also modify the threshold to decide whether to display the unit to be replaced or not. Please contact your service representative for details.

Display the replacement procedure guide and check the procedures of the unit replacement. You can confirm the unit replacement procedure before you actually replace them. If you do not need to display the replacement procedure guide, proceed to step 7. (1) Press [Replacement Procedure].

The ORU-M Replacement Procedure screen is displayed.

bizhub PRESS 1250/1250P/1052

7-5

7
(2)

Prerequisites for Replacing ORU-M Units

7.1

Press a button of an unit that you want to replace, and then press [Procedure Guide View].

The replacement guide screen is displayed. (3) In order to move to previous or next page of the guide, press [*][)] at the bottom of the guide screen.

(4)

When you confirm the replacement procedure, press the [Close] button twice.

The ORU-M Replacement Unit screen will be restored.

7-6

bizhub PRESS 1250/1250P/1052

7.1

Prerequisites for Replacing ORU-M Units

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 8.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) Press [Close].

The ORU-M Replacement Unit screen will be restored.

bizhub PRESS 1250/1250P/1052

7-7

7
8
Press [Start Replacement].

Prerequisites for Replacing ORU-M Units

7.1

The screen to confirm the ORU-M unit replacemen is displayed.

Remove the fusing unit before replacing the unit.

NOTICE
Do not press [Yes] before removing the fusing unit.

NOTICE
When you want to replace a fusing unit or a unit other than the fusing cleaning web, make sure to remove the fusing unit when this screen is displayed.

7-8

bizhub PRESS 1250/1250P/1052

7.1

Prerequisites for Replacing ORU-M Units

(1)

Open the front door.

(2)

Turn the lever M4 [1] in the direction indicated by the arrow, then pull out the ADU drawer [2].

(3)

Open the reversal output part [1].

(4)

Loosen the lock screw (purple) [1] in the direction (counterclockwise) indicated by the arrow.

(5)

Slide the fusing unit [3] in the direction indicated by the arrow while holding both the front side [1] and the rear side [2] handles, then pull up and remove it. CAUTION Be careful in handling the fusing unit because it may be very hot.

bizhub PRESS 1250/1250P/1052

7-9

7
(6)

Prerequisites for Replacing ORU-M Units

7.1

Close the reversal output part and put the ADU drawer back into place.

NOTICE
Please make sure to lift the lever M4 after returning the ADU drawer to its original position.
Press [Yes].

10

Select a unit to replace. Press [Feed Roller Unit(Tray1)] to replace Feed Roller Unit (Tray 1). Press [Feed Roller Unit(Tray2)] to replace Feed Roller Unit (Tray 2).

% To cancel the replacement, press [Cancel] and put the fusing unit back into place. Press [OK].

NOTICE
For the procedure to set the fusing unit, refer to page 7-18.

7-10

bizhub PRESS 1250/1250P/1052

7.1

Prerequisites for Replacing ORU-M Units

11

A message to notify you that the machine is being switched to the ORU-M mode.

Pull out the tray to be replaced and press [Yes].

12

When replacing units, please refer to page 7-12.

NOTICE
You can confirm the replacement procedure by pressing[Replacement Procedure] on the ORU-M Replacement Unit screen and display the replacement procedure guide during the repleacement work. Please refer to step 6 for details.

bizhub PRESS 1250/1250P/1052

7-11

7
7.2 Replacing ORU-M Units
NOTICE

Replacing ORU-M Units

7.2

You can check the procedure of unit replacement on the screen while you are performing the operation.

NOTICE
The replacement of this unit starts with the fusing unit removed. For details on how to remove the fusing unit, refer to page 7-3.

Rotate the pick up roller [1] in the _direction indicated by the arrow (counterclockwise), then make the cutout on coupling [2] vertical. Remove the clips [3] (2 pieces).

NOTICE
Pick up roller [1] can be rotated only in the direction indicated by the arrow (counterclockwise). Please do not rotate in the opposite direction (clockwise).

Remove the bushing (front) [1], then move the bushing (rear) [2] to the rear side on the shaft.

Hold the pick up roller assy [1], raise and rotate the feed roller [3], center it on the pick up roller axis [2], then remove it from the bushing holding metal parts [4][5].

NOTICE
Please be careful not to damage the sensor when removing pick up roller assy.

Release the pick up roller shaft [2] from the feed guide plate arm [1], then remove the pick up roller assy [3].

7-12

bizhub PRESS 1250/1250P/1052

7.2

Replacing ORU-M Units

Remove the clip [1] (1 piece) and the double bushing holder[2] (1 piece).

Remove the pick up roller [1] and the feed roller [2] from the metal plate.

Remove the feed roller shaft clip [1], then remove the feed roller [2] and the pick up roller [3] from the roller shaft.

Remove the feed roller rubber [2] from the feed roller [1]. Remove the pick up roller rubber [4] from the pick up roller [3].

Set the new feed roller rubber [1] to the feed roller [2]. Set the new pick up roller rubber [3] to the pick up roller [4], fitting it to the groove.

bizhub PRESS 1250/1250P/1052

7-13

7
10
Set the feed roller [1] and the pick up roller [2] to the roller shaft [3].

Replacing ORU-M Units

7.2

11

Set the clip [2] to the feed roller shaft [1], then set to the metal plate.

12

Set the double bushing holder [1], then set the clip [2] (1 piece).

13

Remove the clips [1] (2 pieces) on the outside of the tray, then remove the entrance guide plate [2].

14

Remove the clips [1] (2 pieces), then flip over the clear film [2].

NOTICE
Please be careful not to adhere the grease on gear and clear film to the roller surface.

7-14

bizhub PRESS 1250/1250P/1052

7.2

Replacing ORU-M Units

15

Slide the separation roller [1] in the direction indicated by the arrow, then remove it including the roller shaft[2].

16

Remove the clip [1], then remove the separation roller rubber [3] from the roller shaft [2]. Remove the separation roller [4] from the separation roller rubber [3].

17

Set the separation roller [1] to the new separation roller rubber [2], then set the separation roller rubber [2] to the roller shaft[3].Set the clip[4] to the roller shaft [3].

18

Flip over the clear film [1], fix the separation roller [2] including the roller shaft to the shaft holder [3] by sliding in the direction indicated by the arrow, fitting the roller shaft into the shaft holder.

bizhub PRESS 1250/1250P/1052

7-15

7
19
Return the clear film [1] to its original position, then set the clips [2] (2 pieces).

Replacing ORU-M Units

7.2

20

Set the entrance guide plate [1], then set the clips [2] (2 pieces).

21

Insert the pick up roller shaft [1] of the new pick up roller assy to the feed guide plate arm [2].

22

Rotate the pick up roller assy [2] centering on the pick up roller shaft [1], then insert the feed roller shaft [3] and coupling [4] to the cutout [5] and the guide plate joint [6].

NOTICE
Please make sure to engage the coupling of the feed roller to the joint.

NOTICE
Please be careful not to damage the sensor when fixing the pick up roller assy.

7-16

bizhub PRESS 1250/1250P/1052

7.2

Replacing ORU-M Units

23

Insert the bushing(rear) [2] to the holder fixing metal parts opening [3] with slight downward pressure to the pick up roller assy metal plate [1], then insert the bushing (front) [4] to the holder fixing metal part's opening[5].

24

Set the clips [1] (2 pieces). Confirm if the feed roller [3], belt [4], and coupling area[5] can smoothly rotate by turning the pick up roller [2] in the direction indicated by the arrow(counterclockwise).

NOTICE
Pick up roller [1] can be rotated only in the direction indicated by the arrow (counterclockwise). Please do not rotate in the opposite direction (clockwise).

25

Put the tray to its original position.

bizhub PRESS 1250/1250P/1052

7-17

7
7.3

Procedure after ORU-M Unit Replacement

7.3

Procedure after ORU-M Unit Replacement


When you finished replacing the ORU-M unit, go on to the following operations.

When the replacement is completed, press [Complete Replacement] on the ORU-M Replacement Unit screen.

The power of the machine will be turned on automatically.

NOTICE
You can return to the replacement procedures again and restart the procedures if the [Continue replacement] button is displayed on the screen. Please use this button if you need to replace other units. Once you start the adjustment procedure, the [Continue replacement] button is not displayed on this screen and you cannot return to the replacement procedures.

7-18

bizhub PRESS 1250/1250P/1052

7.3

Procedure after ORU-M Unit Replacement

Install the fusing unit.

(1)

Pull out the ADU drawer and open the reversal output part. Set the fusing unit [3] to the correct position while holding both the front side [1] and the rear side [2] handles. Slide the unit in the direction indicated by the arrow until it reaches the rear side.

(2)

Push the lock screw (purple) [1], then tighten by rotating in the direction indicated by the arrow with a screwdriver.

(3)

Close the reversal output part [1].

bizhub PRESS 1250/1250P/1052

7-19

7
(4)

Procedure after ORU-M Unit Replacement

7.3

Insert the ADU drawer [1], then lock it by lifting the lever M4[2] in the direction indicated by the arrow.

(5)

Close the front door.

Press [Yes].

The Register ORU-M Replacement Unit screen is displayed.

7-20

bizhub PRESS 1250/1250P/1052

7.3

Procedure after ORU-M Unit Replacement

Select the name of the replaced unit. % If you have replaced more than one unit, you can select the ones with the same reason to be registered all at once.

If the [Replace Reason] button is not displayed in the list of the Register ORU-M Replacement Unit screen, press the checkbox next to the [Unit Name].

The checkmark is displayed. Proceed to step 5. % You can select multiple unit names at one time. You can perform subsequent tasks together by selecting all units you replaced.

NOTICE
Only service engineer can configure not to display the [Replace Reason] button on the Register ORUM Replacement Unit screen. Please contact your service representative, if desired.

Press the [Replace Reason] button. The dialog to select a reason to replace is displayed.

bizhub PRESS 1250/1250P/1052

7-21

7
5

Procedure after ORU-M Unit Replacement Select a button for replace reason, then press [OK].

7.3

The replace reason that you selected is displayed in the column of [Replace Reason] button and a checkmark is displayed next to the unit name.

NOTICE
Be sure to select a reason for the replacement. Otherwise, the life cycle counter of the replaced unit will not be reset.

Press [Done].

The dialog box asking to reset the counter of the selected unit is displayed.

7-22

bizhub PRESS 1250/1250P/1052

7.3

Procedure after ORU-M Unit Replacement

Press [Yes].

The life cycle counter of the replaced unit will be reset. % Press [No] to retain the current counter value. The screen to review the life of replace ORU-M units is displayed.

Make sure that the life cycle value of the replaced unit has been cleared.

bizhub PRESS 1250/1250P/1052

7-23

7
9
Print a sample image.

Procedure after ORU-M Unit Replacement

7.3

If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 10.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) (4) Confirm the result of the adjustment by comparing the samples before and after the adjustment. Press [Close].

The ORU-M Replacement Unit screen will be restored.

7-24

bizhub PRESS 1250/1250P/1052

7.3

Procedure after ORU-M Unit Replacement

10

Press [Done].

The Machine Screen will be restored.

bizhub PRESS 1250/1250P/1052

7-25

Procedure after ORU-M Unit Replacement

7.3

7-26

bizhub PRESS 1250/1250P/1052

Fusing Cleaning Web

8.1

Prerequisites for Replacing ORU-M Units

Fusing Cleaning Web


When you want to replace an ORU-M unit, switch the machine to the ORU-M mode and follow the procedures on the screen to replace the unit. This document is comprised of the following sections, in order of screen appearance; Prerequisites for Replacing ORU-M Units explains how to switch the machine to the ORU-M mode and prepare for replacement; Replacing ORU-M Units explains the procedures to replace the ORU-M units; and Procedure after ORU-M Unit Replacement explains the procedures to be performed after replacement. You should print this document out and have the hard copy on hand when you start replacement work.

8.1

Prerequisites for Replacing ORU-M Units


In order to start replacing of ORU-M units, follow the following steps to switch the machine to the ORU-M mode.

Press [Utility/Counter]. The Utility screen is displayed.

Press [ORU-M (Unit Replace)].

The screen to agree on the responsibility for the ORU-M operations is displayed. If the ORU-M password is set, the ORU-M Password screen to enter the password is displayed. Proceed to step 4.

bizhub PRESS 1250/1250P/1052

8-3

8
3
If you agree, press [Yes].

Prerequisites for Replacing ORU-M Units

8.1

If you do not agree, press [No]. The Utility screen will be restored.

The ORU-M Replacement Unit screen is displayed. Proceed to step 5.

Enter 4-digit ORU-M password, and then press [OK]. Use half-width alphanumeric characters for the ORU-M password. The half-width alphanumeric characters used for the passwords are case-sensitive. You cannot use symbols and space character.

NOTICE
The ORU-M password is not set initially. If you want to set the ORU-M password, please contact your service representative. The ORU-M password cannot be modified. If you want to modify it, please contact your service representative.

8-4

bizhub PRESS 1250/1250P/1052

8.1

Prerequisites for Replacing ORU-M Units

Confirm the units that you replace on the ORU-M Replacement Unit screen. On this screen, units to be replaced are listed in the order from the nearest replacement time. The value of life cycle will be greater than or equal to 100% and highlighted in red if the replacement time limit of the unit exceed its life cycle. The date of last replacement is displayed on the right column of the list. If you want to replace the unit now, proceed to step 8.

NOTICE
Initially, all units are displayed regardless of the need for replacement. You can configure it to display only the units needed to be replaced. You can also modify the threshold to decide whether to display the unit to be replaced or not. Please contact your service representative for details.

Display the replacement procedure guide and check the procedures of the unit replacement. You can confirm the unit replacement procedure before you actually replace them. If you do not need to display the replacement procedure guide, proceed to step 7. (1) Press [Replacement Procedure].

The ORU-M Replacement Procedure screen is displayed.

bizhub PRESS 1250/1250P/1052

8-5

8
(2)

Prerequisites for Replacing ORU-M Units

8.1

Press a button of an unit that you want to replace, and then press [Procedure Guide View].

The replacement guide screen is displayed. (3) In order to move to previous or next page of the guide, press [*][)] at the bottom of the guide screen.

(4)

When you confirm the replacement procedure, press the [Close] button twice.

The ORU-M Replacement Unit screen will be restored.

8-6

bizhub PRESS 1250/1250P/1052

8.1

Prerequisites for Replacing ORU-M Units

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 8.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) Press [Close].

The ORU-M Replacement Unit screen will be restored.

bizhub PRESS 1250/1250P/1052

8-7

8
8
Press [Start Replacement].

Prerequisites for Replacing ORU-M Units

8.1

The screen to confirm the ORU-M unit replacemen is displayed.

Press [Yes].

8-8

bizhub PRESS 1250/1250P/1052

8.1

Prerequisites for Replacing ORU-M Units

10

Select a unit to replace. Press [Others], then press [OK].

% To stop the replacement operation, press [Cancel].

11

A message to notify you that the machine is being switched to the ORU-M mode.

Make sure that the lever M4 is brought down and Tray 1 and Tray 2 are correctly set, then press [Yes].For details on how to turn down the lever, refer to step 2 on p.3-2.

bizhub PRESS 1250/1250P/1052

8-9

8
12
When replacing units, please refer to page 8-11.

Prerequisites for Replacing ORU-M Units

8.1

NOTICE
You can confirm the replacement procedure by pressing[Replacement Procedure] on the ORU-M Replacement Unit screen and display the replacement procedure guide during the repleacement work. Please refer to step 6 for details.

8-10

bizhub PRESS 1250/1250P/1052

8.2

Replacing ORU-M Units

8.2

Replacing ORU-M Units


NOTICE
You can check the procedure of unit replacement on the screen while you are performing the operation.

Open the front door.

Turn the lever M4[1] in the direction indicated by the arrow, then pull out the ADU drawer [2].

Remove the screws [1] (2 pieces).

Remove the top part of the fusing unit [1][2] while holding the knobs [3]. CAUTION Be careful in handling the fusing unit because it may be very hot.

bizhub PRESS 1250/1250P/1052

8-11

8
5
Remove the used fusing cleaning web [1] by sliding it in the direction indicated by the arrow. CAUTION Be careful when you perform the replacement because the top part of the fusing unit may be very hot.

Replacing ORU-M Units

8.2

Set the web supply roller [1] and collection roller [2] of the new fusing cleaning web.

Wind the web on the collection roller until the blue line [3] on the web completely disappears by rotating the gears [1][2].

Set the top part of the fusing unit [3] while holding the knobs [1][2], then push the knobs down.

Tighten the screws [1] (2 pieces).

8-12

bizhub PRESS 1250/1250P/1052

8.2

Replacing ORU-M Units

10

Insert the ADU drawer [1] then lock it by lifting the ADU release lever [2] in the direction indicated by the arrow.

11

Close the front door.

bizhub PRESS 1250/1250P/1052

8-13

8
8.3

Procedure after ORU-M Unit Replacement

8.3

Procedure after ORU-M Unit Replacement


When you finished replacing the ORU-M unit, go on to the following operations.

When the replacement is completed, press [Complete Replacement] on the ORU-M Replacement Unit screen.

The power of the machine will be turned on automatically.

NOTICE
You can return to the replacement procedures again and restart the procedures if the [Continue replacement] button is displayed on the screen. Please use this button if you need to replace other units. Once you start the adjustment procedure, the [Continue replacement] button is not displayed on this screen and you cannot return to the replacement procedures.

8-14

bizhub PRESS 1250/1250P/1052

8.3

Procedure after ORU-M Unit Replacement Press [Yes].

The Register ORU-M Replacement Unit screen is displayed.

bizhub PRESS 1250/1250P/1052

8-15

8
2
Select the name of the replaced unit.

Procedure after ORU-M Unit Replacement

8.3

% If you have replaced more than one unit, you can select the ones with the same reason to be registered all at once.

If the [Replace Reason] button is not displayed in the list of the Register ORU-M Replacement Unit screen, press the checkbox next to the [Unit Name].

The checkmark is displayed. Proceed to step 5. % You can select multiple unit names at one time. You can perform subsequent tasks together by selecting all units you replaced.

NOTICE
Only service engineer can configure not to display the [Replace Reason] button on the Register ORUM Replacement Unit screen. Please contact your service representative, if desired.

Press the [Replace Reason] button. The dialog to select a reason to replace is displayed.

8-16

bizhub PRESS 1250/1250P/1052

8.3

Procedure after ORU-M Unit Replacement

Select a button for replace reason, then press [OK].

The replace reason that you selected is displayed in the column of [Replace Reason] button and a checkmark is displayed next to the unit name.

NOTICE
Be sure to select a reason for the replacement. Otherwise, the life cycle counter of the replaced unit will not be reset.

Press [Done].

The dialog box asking to reset the counter of the selected unit is displayed.

bizhub PRESS 1250/1250P/1052

8-17

8
6
Press [Yes].

Procedure after ORU-M Unit Replacement

8.3

The life cycle counter of the replaced unit will be reset. % Press [No] to retain the current counter value. The screen to review the life of replace ORU-M units is displayed.

Make sure that the life cycle value of the replaced unit has been cleared.

8-18

bizhub PRESS 1250/1250P/1052

8.3

Procedure after ORU-M Unit Replacement

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 10.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) (4) Confirm the result of the adjustment by comparing the samples before and after the adjustment. Press [Close].

The ORU-M Replacement Unit screen will be restored.

bizhub PRESS 1250/1250P/1052

8-19

8
9
Press [Done].

Procedure after ORU-M Unit Replacement

8.3

The Machine Screen will be restored.

8-20

bizhub PRESS 1250/1250P/1052

Drum Cleaner

9.1

Prerequisites for Replacing ORU-M Units

Drum Cleaner
When you want to replace an ORU-M unit, switch the machine to the ORU-M mode and follow the procedures on the screen to replace the unit. This document is comprised of the following sections, in order of screen appearance; Prerequisites for Replacing ORU-M Units explains how to switch the machine to the ORU-M mode and prepare for replacement; Replacing ORU-M Units explains the procedures to replace the ORU-M units; and Procedure after ORU-M Unit Replacement explains the procedures to be performed after replacement. You should print this document out and have the hard copy on hand when you start replacement work.

9.1

Prerequisites for Replacing ORU-M Units


In order to start replacing of ORU-M units, follow the following steps to switch the machine to the ORU-M mode.

Press [Utility/Counter]. The Utility screen is displayed.

Press [ORU-M (Unit Replace)].

The screen to agree on the responsibility for the ORU-M operations is displayed. If the ORU-M password is set, the ORU-M Password screen to enter the password is displayed. Proceed to step 4.

bizhub PRESS 1250/1250P/1052

9-3

9
3
If you agree, press [Yes].

Prerequisites for Replacing ORU-M Units

9.1

If you do not agree, press [No]. The Utility screen will be restored.

The ORU-M Replacement Unit screen is displayed. Proceed to step 5.

Enter 4-digit ORU-M password, and then press [OK]. Use half-width alphanumeric characters for the ORU-M password. The half-width alphanumeric characters used for the passwords are case-sensitive. You cannot use symbols and space character.

NOTICE
The ORU-M password is not set initially. If you want to set the ORU-M password, please contact your service representative. The ORU-M password cannot be modified. If you want to modify it, please contact your service representative.

9-4

bizhub PRESS 1250/1250P/1052

9.1

Prerequisites for Replacing ORU-M Units

Confirm the units that you replace on the ORU-M Replacement Unit screen. On this screen, units to be replaced are listed in the order from the nearest replacement time. The value of life cycle will be greater than or equal to 100% and highlighted in red if the replacement time limit of the unit exceed its life cycle. The date of last replacement is displayed on the right column of the list. If you want to replace the unit now, proceed to step 8.

NOTICE
Initially, all units are displayed regardless of the need for replacement. You can configure it to display only the units needed to be replaced. You can also modify the threshold to decide whether to display the unit to be replaced or not. Please contact your service representative for details.

Display the replacement procedure guide and check the procedures of the unit replacement. You can confirm the unit replacement procedure before you actually replace them. If you do not need to display the replacement procedure guide, proceed to step 7. (1) Press [Replacement Procedure].

The ORU-M Replacement Procedure screen is displayed.

bizhub PRESS 1250/1250P/1052

9-5

9
(2)

Prerequisites for Replacing ORU-M Units

9.1

Press a button of an unit that you want to replace, and then press [Procedure Guide View].

The replacement guide screen is displayed. (3) In order to move to previous or next page of the guide, press [*][)] at the bottom of the guide screen.

(4)

When you confirm the replacement procedure, press the [Close] button twice.

The ORU-M Replacement Unit screen will be restored.

9-6

bizhub PRESS 1250/1250P/1052

9.1

Prerequisites for Replacing ORU-M Units

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 8.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) Press [Close].

The ORU-M Replacement Unit screen will be restored.

bizhub PRESS 1250/1250P/1052

9-7

9
8
Press [Start Replacement].

Prerequisites for Replacing ORU-M Units

9.1

The screen to confirm the ORU-M unit replacemen is displayed.

Remove the fusing unit before replacing the unit.

NOTICE
Do not press [Yes] before removing the fusing unit.

NOTICE
When you want to replace a fusing unit or a unit other than the fusing cleaning web, make sure to remove the fusing unit when this screen is displayed.

9-8

bizhub PRESS 1250/1250P/1052

9.1

Prerequisites for Replacing ORU-M Units

(1)

Open the front door.

(2)

Turn the lever M4 [1] in the direction indicated by the arrow, then pull out the ADU drawer [2].

(3)

Open the reversal output part [1].

(4)

Loosen the lock screw (purple) [1] in the direction (counterclockwise) indicated by the arrow.

(5)

Slide the fusing unit [3] in the direction indicated by the arrow while holding both the front side [1] and the rear side [2] handles, then pull up and remove it. CAUTION Be careful in handling the fusing unit because it may be very hot.

bizhub PRESS 1250/1250P/1052

9-9

9
(6)

Prerequisites for Replacing ORU-M Units

9.1

Close the reversal output part and put the ADU drawer back into place.

NOTICE
Please make sure not lift the lever M4 after returning the ADU drawer to its original position.
Press [Yes].

10

Select a unit to replace. Press [Others], then press [OK].

% To cancel the replacement, press [Cancel] and put the fusing unit back into place. Press [OK].

NOTICE
For the procedure to set the fusing unit, refer to page 9-16.

9-10

bizhub PRESS 1250/1250P/1052

9.1

Prerequisites for Replacing ORU-M Units

11

A message to notify you that the machine is being switched to the ORU-M mode.

Make sure that the lever M4 is brought down and Tray 1 and Tray 2 are correctly set, then press [Yes].For details on how to turn down the lever, refer to step (2) on p.2-8.

12

When replacing units, please refer to page 9-12.

NOTICE
You can confirm the replacement procedure by pressing[Replacement Procedure] on the ORU-M Replacement Unit screen and display the replacement procedure guide during the repleacement work. Please refer to step 6 for details.

bizhub PRESS 1250/1250P/1052

9-11

9
9.2 Replacing ORU-M Units
NOTICE

Replacing ORU-M Units

9.2

You can check the procedure of unit replacement on the screen while you are performing the operation.

NOTICE
The replacement of this unit starts with the fusing unit removed. For details on how to remove the fusing unit, refer to page 9-3.

Loosen the screws [1] (2 pieces), then remove the cover of the drum part [2].

Release the lock [1] and pull out the intermediate toner hopper, then release the lock [2] and open in the direction indicated by the arrow.

Disconnect the LPH connectors [1] (2 pieces).

Slowly rotate the drum lock knob [1] clockwise [2] more than one revolution in order to remove the toner on the drum. Then, firmly rotate the drum lock knob counterclockwise [3] to remove it[1].

9-12

bizhub PRESS 1250/1250P/1052

9.2

Replacing ORU-M Units

Turn the left [1] and right [2] lock levers in the direction indicated by the arrow, then pull out the drum part to the front.

Release the wire saddles [1] (2 pieces), then disconnect the connector [2]. Lift up the cleaning set levers [3] (2 pieces) to release.

As the illustration shows, put both thumbs into [1] (2 positions), then remove the cleaning part [2] while rotating it in the direction indicated by [3].

NOTICE
When removing the cleaning part, rotate it at an angle of about 15 degrees away from the drum.

As the illustration shows, put both thumbs into [1] (2 positions) of the new cleaning part [2], set in fitting , then rotate it in the direction of the drum (indicated by the arrow) [3] to fix it.

NOTICE
Be careful not to catch the bundled cables when fixing the cleaning part.
Confirm the blade lever [4] has been lowered.

NOTICE
If the blade lever [4] has been lifted, perform the following steps to lower the lever.
(1) (2) (3) Keep the left side lever of the cleaning part lifted towards the direction indicated by the arrow. Rotate the blade lever [4] all the way down in the direction indicated by the arrow, then release it. Release the left side lever.

bizhub PRESS 1250/1250P/1052

9-13

9
9
Lock the cleaning set levers [1] (2 pieces). Connect the connector [2]. Fix the wire by the wire saddle [3] (2 pieces).

Replacing ORU-M Units

9.2

NOTICE
Do not forget to connect the drum cleaner connector.

10

Insert the drum part [3] with holding the drum lock levers [1][2], then lock the drum lock levers [1][2] by rotating them in the direction indicated by the arrow.

11

Fix the drum lock knob [1], and tighten it by rotating clockwise.

NOTICE
If the coupling of the drum is sticking out to the front, make sure to push it back in.

12

Connect the LPH connectors [1] (2 pieces).

NOTICE
Do not forget to connect the LPH connectors.

9-14

bizhub PRESS 1250/1250P/1052

9.2

Replacing ORU-M Units

13

Return the intermediate toner hopper [1] to its original position. Set the lock levers [2][3].

NOTICE
Push the PUSH mark on the intermediate toner hopper firmly until it makes a clicking noise and confirm it is locked.

14

Fix the cover of the drum part [1], then tighten the screws [2] (2 pieces) on the right first then the left.

bizhub PRESS 1250/1250P/1052

9-15

9
9.3

Procedure after ORU-M Unit Replacement

9.3

Procedure after ORU-M Unit Replacement


When you finished replacing the ORU-M unit, go on to the following operations.

When the replacement is completed, press [Complete Replacement] on the ORU-M Replacement Unit screen.

The power of the machine will be turned on automatically.

NOTICE
You can return to the replacement procedures again and restart the procedures if the [Continue replacement] button is displayed on the screen. Please use this button if you need to replace other units. Once you start the adjustment procedure, the [Continue replacement] button is not displayed on this screen and you cannot return to the replacement procedures.

9-16

bizhub PRESS 1250/1250P/1052

9.3

Procedure after ORU-M Unit Replacement

Install the fusing unit.

(1)

Pull out the ADU drawer and open the reversal output part. Set the fusing unit [3] to the correct position while holding both the front side [1] and the rear side [2] handles. Slide the unit in the direction indicated by the arrow until it reaches the rear side.

(2)

Push the lock screw (purple) [1], then tighten by rotating in the direction indicated by the arrow with a screwdriver.

(3)

Close the reversal output part [1].

bizhub PRESS 1250/1250P/1052

9-17

9
(4)

Procedure after ORU-M Unit Replacement

9.3

Insert the ADU drawer [1], then lock it by lifting the lever M4[2] in the direction indicated by the arrow.

(5)

Close the front door.

Press [Yes].

NOTICE
If a connector of the drum cleaner or LPH is not connected after the drum cleaner is replaced, the Detected disengagement of connector screen will be displayed.

9-18

bizhub PRESS 1250/1250P/1052

9.3

Procedure after ORU-M Unit Replacement

(1)

Open the front door, turn the lever M4 down, then press [OK].

The screen notifying you of ORU-M connector disengagement. (2) Press [NG] of the Status field for the disconnected connector.

A detailed screen to show the place of the disconnected connector will be displayed.

bizhub PRESS 1250/1250P/1052

9-19

9
(3)

Procedure after ORU-M Unit Replacement

9.3

Refer to page 9-12 and connect the appropriate connector.

Press [Close] on the sub-screen (4) (5) (6) Lift the lever M4 to lock. Close the front door. Press [Close].

The Register ORU-M Replacement Unit screen is displayed.

Select the name of the replaced unit. % If you have replaced more than one unit, you can select the ones with the same reason to be registered all at once.

9-20

bizhub PRESS 1250/1250P/1052

9.3

Procedure after ORU-M Unit Replacement If the [Replace Reason] button is not displayed in the list of the Register ORU-M Replacement Unit screen, press the checkbox next to the [Unit Name].

The checkmark is displayed. Proceed to step 5. % You can select multiple unit names at one time. You can perform subsequent tasks together by selecting all units you replaced.

NOTICE
Only service engineer can configure not to display the [Replace Reason] button on the Register ORUM Replacement Unit screen. Please contact your service representative, if desired.

4 5

Press the [Replace Reason] button. The dialog to select a reason to replace is displayed. Select a button for replace reason, then press [OK].

The replace reason that you selected is displayed in the column of [Replace Reason] button and a checkmark is displayed next to the unit name.

bizhub PRESS 1250/1250P/1052

9-21

9
NOTICE

Procedure after ORU-M Unit Replacement

9.3

Be sure to select a reason for the replacement. Otherwise, the life cycle counter of the replaced unit will not be reset.

Press [Done].

The dialog box asking to reset the counter of the selected unit is displayed.

Press [Yes].

The life cycle counter of the replaced unit will be reset. % Press [No] to retain the current counter value. The screen to review the life of replace ORU-M units is displayed.

9-22

bizhub PRESS 1250/1250P/1052

9.3

Procedure after ORU-M Unit Replacement

Make sure that the life cycle value of the replaced unit has been cleared.

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 10.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed.

bizhub PRESS 1250/1250P/1052

9-23

9
(2)

Procedure after ORU-M Unit Replacement

9.3

Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) (4) Confirm the result of the adjustment by comparing the samples before and after the adjustment. Press [Close].

The ORU-M Replacement Unit screen will be restored.

10

Press [Done].

The Machine Screen will be restored.

9-24

bizhub PRESS 1250/1250P/1052

10

LPH

10.1

Prerequisites for Replacing ORU-M Units

10

10

LPH
When you want to replace an ORU-M unit, switch the machine to the ORU-M mode and follow the procedures on the screen to replace the unit. This document is comprised of the following sections, in order of screen appearance; Prerequisites for Replacing ORU-M Units explains how to switch the machine to the ORU-M mode and prepare for replacement; Replacing ORU-M Units explains the procedures to replace the ORU-M units; and Procedure after ORU-M Unit Replacement explains the procedures to be performed after replacement. You should print this document out and have the hard copy on hand when you start replacement work.

10.1

Prerequisites for Replacing ORU-M Units


In order to start replacing of ORU-M units, follow the following steps to switch the machine to the ORU-M mode.

Press [Utility/Counter]. The Utility screen is displayed.

Press [ORU-M (Unit Replace)].

The screen to agree on the responsibility for the ORU-M operations is displayed. If the ORU-M password is set, the ORU-M Password screen to enter the password is displayed. Proceed to step 4.

bizhub PRESS 1250/1250P/1052

10-3

10
3
If you agree, press [Yes].

Prerequisites for Replacing ORU-M Units

10.1

If you do not agree, press [No]. The Utility screen will be restored.

The ORU-M Replacement Unit screen is displayed. Proceed to step 5.

Enter 4-digit ORU-M password, and then press [OK]. Use half-width alphanumeric characters for the ORU-M password. The half-width alphanumeric characters used for the passwords are case-sensitive. You cannot use symbols and space character.

NOTICE
The ORU-M password is not set initially. If you want to set the ORU-M password, please contact your service representative. The ORU-M password cannot be modified. If you want to modify it, please contact your service representative.

10-4

bizhub PRESS 1250/1250P/1052

10.1

Prerequisites for Replacing ORU-M Units

10

Confirm the units that you replace on the ORU-M Replacement Unit screen. On this screen, units to be replaced are listed in the order from the nearest replacement time. The value of life cycle will be greater than or equal to 100% and highlighted in red if the replacement time limit of the unit exceed its life cycle. The date of last replacement is displayed on the right column of the list. If you want to replace the unit now, proceed to step 8.

NOTICE
Initially, all units are displayed regardless of the need for replacement. You can configure it to display only the units needed to be replaced. You can also modify the threshold to decide whether to display the unit to be replaced or not. Please contact your service representative for details.

NOTICE
Although LPH is an ORU-M unit, the only operation you can perform is cleaning and it cannot be replaced and has no life cycle counter.Therefore, the life cycle is displayed blank regardless of the ORUM Life Threshold Setting.

bizhub PRESS 1250/1250P/1052

10-5

10
6

Prerequisites for Replacing ORU-M Units Display the replacement procedure guide and check the procedures of the unit replacement. You can confirm the unit replacement procedure before you actually replace them. If you do not need to display the replacement procedure guide, proceed to step 7. (1) Press [Replacement Procedure].

10.1

The ORU-M Replacement Procedure screen is displayed. (2) Press a button of an unit that you want to replace, and then press [Procedure Guide View].

The replacement guide screen is displayed.

10-6

bizhub PRESS 1250/1250P/1052

10.1

Prerequisites for Replacing ORU-M Units

10

(3)

In order to move to previous or next page of the guide, press [*][)] at the bottom of the guide screen.

(4)

When you confirm the replacement procedure, press the [Close] button twice.

The ORU-M Replacement Unit screen will be restored.

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 8.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed.

bizhub PRESS 1250/1250P/1052

10-7

10
(2)

Prerequisites for Replacing ORU-M Units

10.1

Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) Press [Close].

The ORU-M Replacement Unit screen will be restored.

Press [Start Replacement].

The screen to confirm the ORU-M unit replacemen is displayed.

10-8

bizhub PRESS 1250/1250P/1052

10.1

Prerequisites for Replacing ORU-M Units

10

Remove the fusing unit before replacing the unit.

NOTICE
Do not press [Yes] before removing the fusing unit.

NOTICE
When you want to replace a fusing unit or a unit other than the fusing cleaning web, make sure to remove the fusing unit when this screen is displayed.
(1) Open the front door.

(2)

Turn the lever M4 [1] in the direction indicated by the arrow, then pull out the ADU drawer [2].

bizhub PRESS 1250/1250P/1052

10-9

10
(3) Open the reversal output part [1].

Prerequisites for Replacing ORU-M Units

10.1

(4)

Loosen the lock screw (purple) [1] in the direction (counterclockwise) indicated by the arrow.

(5)

Slide the fusing unit [3] in the direction indicated by the arrow while holding both the front side [1] and the rear side [2] handles, then pull up and remove it. CAUTION Be careful in handling the fusing unit because it may be very hot.

(6)

Close the reversal output part and put the ADU drawer back into place.

NOTICE
Please make sure not lift the lever M4 after returning the ADU drawer to its original position.
Press [Yes].

10-10

bizhub PRESS 1250/1250P/1052

10.1

Prerequisites for Replacing ORU-M Units

10

10

Select a unit to replace. Press [Others], then press [OK].

% To cancel the replacement, press [Cancel] and put the fusing unit back into place. Press [OK].

NOTICE
For the procedure to set the fusing unit, refer to page 10-17.

bizhub PRESS 1250/1250P/1052

10-11

10
11

Prerequisites for Replacing ORU-M Units A message to notify you that the machine is being switched to the ORU-M mode.

10.1

Make sure that the lever M4 is brought down and Tray 1 and Tray 2 are correctly set, then press [Yes].For details on how to turn down the lever, refer to step (2) on p.2-8.

12

When replacing units, please refer to page 10-13.

NOTICE
You can confirm the replacement procedure by pressing[Replacement Procedure] on the ORU-M Replacement Unit screen and display the replacement procedure guide during the repleacement work. Please refer to step 6 for details.

10-12

bizhub PRESS 1250/1250P/1052

10.2

Replacing ORU-M Units

10

10.2

Replacing ORU-M Units


NOTICE
The only operation you can perform on LPH is cleaning; it cannot be replaced.

NOTICE
You can check the procedure of unit replacement on the screen while you are performing the operation.

NOTICE
The replacement of this unit starts with the fusing unit removed. For details on how to remove the fusing unit, refer to page 10-3.

Loosen the screws [1] (2 pieces), then remove the cover of the drum part [2].

Release the lock [1] and pull out the intermediate toner hopper, then release the lock [2] and open in the direction indicated by the arrow.

Disconnect the LPH connectors [1] (2 pieces).

Slowly rotate the drum lock knob [1] clockwise [2] more than one revolution in order to remove the toner on the drum. Then, firmly rotate the drum lock knob counterclockwise [3] to remove it[1].

bizhub PRESS 1250/1250P/1052

10-13

10
5
Turn the left [1] and right [2] lock levers in the direction indicated by the arrow, then pull out the drum part to the front.

Replacing ORU-M Units

10.2

Release the wire [1] from the wire guide [2].

Remove the unit while holding the front side [1] and the rear side [2].

Clean the lens of the LPH unit with a cotton swab.

NOTICE
Move a cotton swab in a single direction.

Set the cleaned LPH unit to the fitting position, then firmly push and set the front side [1] first and the rear side [2] second.

NOTICE
Be careful not to catch the bundled cables when installing the LPH unit.

10-14

bizhub PRESS 1250/1250P/1052

10.2

Replacing ORU-M Units

10

10

Set the wire [1] in the wire guide [2].

11

Insert the drum part [3] holding the drum lock levers [1][2], then lock the drum lock levers [1][2] by rotating them in the direction indicated by the arrow.

12

Fix the drum lock knob [1], and tighten it by rotating clockwise.

NOTICE
If the coupling of the drum is sticking out to the front, make sure to push it back in.

13

Connect the LPH connectors [1] (2 pieces).

NOTICE
Do not forget to connect the LPH connectors.

bizhub PRESS 1250/1250P/1052

10-15

10
14
Return the intermediate toner hopper [1] to its original position. Set the lock levers [2][3].

Replacing ORU-M Units

10.2

NOTICE
Push the PUSH mark on the intermediate toner hopper firmly until it makes a clicking noise and confirm it is locked.

15

Fix the cover of the drum part [1], then tighten the screws [2] (2 pieces) on the right first then the left.

10-16

bizhub PRESS 1250/1250P/1052

10.3

Procedure after ORU-M Unit Replacement

10

10.3

Procedure after ORU-M Unit Replacement


When you finished replacing the ORU-M unit, go on to the following operations.

When the replacement is completed, press [Complete Replacement] on the ORU-M Replacement Unit screen.

The power of the machine will be turned on automatically.

NOTICE
You can return to the replacement procedures again and restart the procedures if the [Continue replacement] button is displayed on the screen. Please use this button if you need to replace other units. Once you start the adjustment procedure, the [Continue replacement] button is not displayed on this screen and you cannot return to the replacement procedures.

bizhub PRESS 1250/1250P/1052

10-17

10
2
Install the fusing unit.

Procedure after ORU-M Unit Replacement

10.3

(1)

Pull out the ADU drawer and open the reversal output part. Set the fusing unit [3] to the correct position while holding both the front side [1] and the rear side [2] handles. Slide the unit in the direction indicated by the arrow until it reaches the rear side.

(2)

Push the lock screw (purple) [1], then tighten by rotating in the direction indicated by the arrow with a screwdriver.

(3)

Close the reversal output part [1].

10-18

bizhub PRESS 1250/1250P/1052

10.3

Procedure after ORU-M Unit Replacement

10

(4)

Insert the ADU drawer [1], then lock it by lifting the lever M4[2] in the direction indicated by the arrow.

(5)

Close the front door.

Press [Yes].

NOTICE
If a connector of the LPH is not connected after its replacement, the Detected disengagement of connector screen will be displayed.

bizhub PRESS 1250/1250P/1052

10-19

10
(1)

Procedure after ORU-M Unit Replacement

10.3

Open the front door, turn the lever M4 down, then press [OK].

The screen notifying you of ORU-M connector disengagement. (2) Press [NG] of the Status field for the disconnected connector.

A detailed screen to show the place of the disconnected connector will be displayed.

10-20

bizhub PRESS 1250/1250P/1052

10.3

Procedure after ORU-M Unit Replacement

10

(3)

Refer to page 10-13 and connect the appropriate connector.

Press [Close] on the sub-screen (4) (5) (6) Lift the lever M4 to lock. Close the front door. Press [Close].

The Register ORU-M Replacement Unit screen is displayed.

Select the name of the replaced unit. % If you have replaced more than one unit, you can select the ones with the same reason to be registered all at once.

bizhub PRESS 1250/1250P/1052

10-21

10

Procedure after ORU-M Unit Replacement

10.3

If the [Replace Reason] button is not displayed in the list of the Register ORU-M Replacement Unit screen, press the checkbox next to the [Unit Name].

The checkmark is displayed. Proceed to step 5. % You can select multiple unit names at one time. You can perform subsequent tasks together by selecting all units you replaced.

NOTICE
Only service engineer can configure not to display the [Replace Reason] button on the Register ORUM Replacement Unit screen. Please contact your service representative, if desired.

4 5

Press the [Replace Reason] button. The dialog to select a reason to replace is displayed. Select a button for replace reason, then press [OK].

The replace reason that you selected is displayed in the column of [Replace Reason] button and a checkmark is displayed next to the unit name.

10-22

bizhub PRESS 1250/1250P/1052

10.3

Procedure after ORU-M Unit Replacement

10

NOTICE
Be sure to select a reason for the replacement. Otherwise, the life cycle counter of the replaced unit will not be reset.

Press [Done].

The dialog box asking to reset the counter of the selected unit is displayed.

Press [Yes].

The life cycle counter of the replaced unit will be reset. % Press [No] to retain the current counter value. The screen to review the life of replace ORU-M units is displayed.

bizhub PRESS 1250/1250P/1052

10-23

10
8

Procedure after ORU-M Unit Replacement Make sure that the life cycle value of the replaced unit has been cleared.

10.3

NOTICE
The life cycle value displayed depends on the Life Threshold Setting and the setting of the target unit. Since LPH has no life cycle counter, it is displayed blank regardless of the Life Threshold Setting.

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 10.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed.

10-24

bizhub PRESS 1250/1250P/1052

10.3

Procedure after ORU-M Unit Replacement

10

(2)

Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) (4) Confirm the result of the adjustment by comparing the samples before and after the adjustment. Press [Close].

The ORU-M Replacement Unit screen will be restored.

10

Press [Done].

The Machine Screen will be restored.

bizhub PRESS 1250/1250P/1052

10-25

10

Procedure after ORU-M Unit Replacement

10.3

10-26

bizhub PRESS 1250/1250P/1052

11

PCC

11.1

Prerequisites for Replacing ORU-M Units

11

11

PCC
When you want to replace an ORU-M unit, switch the machine to the ORU-M mode and follow the procedures on the screen to replace the unit. This document is comprised of the following sections, in order of screen appearance; Prerequisites for Replacing ORU-M Units explains how to switch the machine to the ORU-M mode and prepare for replacement; Replacing ORU-M Units explains the procedures to replace the ORU-M units; and Procedure after ORU-M Unit Replacement explains the procedures to be performed after replacement. You should print this document out and have the hard copy on hand when you start replacement work.

11.1

Prerequisites for Replacing ORU-M Units


In order to start replacing of ORU-M units, follow the following steps to switch the machine to the ORU-M mode.

Press [Utility/Counter]. The Utility screen is displayed.

Press [ORU-M (Unit Replace)].

The screen to agree on the responsibility for the ORU-M operations is displayed. If the ORU-M password is set, the ORU-M Password screen to enter the password is displayed. Proceed to step 4.

bizhub PRESS 1250/1250P/1052

11-3

11
3
If you agree, press [Yes].

Prerequisites for Replacing ORU-M Units

11.1

If you do not agree, press [No]. The Utility screen will be restored.

The ORU-M Replacement Unit screen is displayed. Proceed to step 5.

Enter 4-digit ORU-M password, and then press [OK]. Use half-width alphanumeric characters for the ORU-M password. The half-width alphanumeric characters used for the passwords are case-sensitive. You cannot use symbols and space character.

NOTICE
The ORU-M password is not set initially. If you want to set the ORU-M password, please contact your service representative. The ORU-M password cannot be modified. If you want to modify it, please contact your service representative.

11-4

bizhub PRESS 1250/1250P/1052

11.1

Prerequisites for Replacing ORU-M Units

11

Confirm the units that you replace on the ORU-M Replacement Unit screen. On this screen, units to be replaced are listed in the order from the nearest replacement time. The value of life cycle will be greater than or equal to 100% and highlighted in red if the replacement time limit of the unit exceed its life cycle. The date of last replacement is displayed on the right column of the list. If you want to replace the unit now, proceed to step 8.

NOTICE
Initially, all units are displayed regardless of the need for replacement. You can configure it to display only the units needed to be replaced. You can also modify the threshold to decide whether to display the unit to be replaced or not. Please contact your service representative for details.

Display the replacement procedure guide and check the procedures of the unit replacement. You can confirm the unit replacement procedure before you actually replace them. If you do not need to display the replacement procedure guide, proceed to step 7. (1) Press [Replacement Procedure].

The ORU-M Replacement Procedure screen is displayed.

bizhub PRESS 1250/1250P/1052

11-5

11
(2)

Prerequisites for Replacing ORU-M Units

11.1

Press a button of an unit that you want to replace, and then press [Procedure Guide View].

The replacement guide screen is displayed. (3) In order to move to previous or next page of the guide, press [*][)] at the bottom of the guide screen.

(4)

When you confirm the replacement procedure, press the [Close] button twice.

The ORU-M Replacement Unit screen will be restored.

11-6

bizhub PRESS 1250/1250P/1052

11.1

Prerequisites for Replacing ORU-M Units

11

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 8.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) Press [Close].

The ORU-M Replacement Unit screen will be restored.

bizhub PRESS 1250/1250P/1052

11-7

11
8
Press [Start Replacement].

Prerequisites for Replacing ORU-M Units

11.1

The screen to confirm the ORU-M unit replacemen is displayed.

Remove the fusing unit before replacing the unit.

NOTICE
Do not press [Yes] before removing the fusing unit.

NOTICE
When you want to replace a fusing unit or a unit other than the fusing cleaning web, make sure to remove the fusing unit when this screen is displayed.

11-8

bizhub PRESS 1250/1250P/1052

11.1

Prerequisites for Replacing ORU-M Units

11

(1)

Open the front door.

(2)

Turn the lever M4 [1] in the direction indicated by the arrow, then pull out the ADU drawer [2].

(3)

Open the reversal output part [1].

(4)

Loosen the lock screw (purple) [1] in the direction (counterclockwise) indicated by the arrow.

(5)

Slide the fusing unit [3] in the direction indicated by the arrow while holding both the front side [1] and the rear side [2] handles, then pull up and remove it. CAUTION Be careful in handling the fusing unit because it may be very hot.

bizhub PRESS 1250/1250P/1052

11-9

11
(6)

Prerequisites for Replacing ORU-M Units

11.1

Close the reversal output part and put the ADU drawer back into place.

NOTICE
Please make sure not lift the lever M4 after returning the ADU drawer to its original position.
Press [Yes].

10

Select a unit to replace. Press [Others], then press [OK].

% To cancel the replacement, press [Cancel] and put the fusing unit back into place. Press [OK].

NOTICE
For the procedure to set the fusing unit, refer to page 11-18.

11-10

bizhub PRESS 1250/1250P/1052

11.1

Prerequisites for Replacing ORU-M Units

11

11

A message to notify you that the machine is being switched to the ORU-M mode.

Make sure that the lever M4 is brought down and Tray 1 and Tray 2 are correctly set, then press [Yes].For details on how to turn down the lever, refer to step (2) on p.2-8.

12

When replacing units, please refer to page 11-12.

NOTICE
You can confirm the replacement procedure by pressing[Replacement Procedure] on the ORU-M Replacement Unit screen and display the replacement procedure guide during the repleacement work. Please refer to step 6 for details.

bizhub PRESS 1250/1250P/1052

11-11

11
11.2 Replacing ORU-M Units
NOTICE

Replacing ORU-M Units

11.2

You can check the procedure of unit replacement on the screen while you are performing the operation.

NOTICE
The replacement of this unit starts with the fusing unit removed. For details on how to remove the fusing unit, refer to page 11-3.

Loosen the screws [1] (2 pieces), then remove the cover of the drum part [2].

Release the lock [1] and pull out the intermediate toner hopper, then release the lock [2] and open in the direction indicated by the arrow.

Disconnect the LPH connectors [1] (2 pieces).

Slowly rotate the drum lock knob [1] clockwise [2] more than one revolution in order to remove the toner on the drum. Then, firmly rotate the drum lock knob counterclockwise [3] to remove it[1].

11-12

bizhub PRESS 1250/1250P/1052

11.2

Replacing ORU-M Units

11

Turn the left [1] and right [2] lock levers in the direction indicated by the arrow, then pull out the drum part to the front.

Remove the charging corona unit. (1) Release the wire saddle [1], then disconnect the connectors [2] (2 pieces).

(2)

Remove the charging corona unit [3] while holding the areas [1] and [2].

Remove the drum cleaner. (1) Release the wire saddles [1] (2 pieces), then disconnect the connector [2]. Lift up the cleaning set levers [3] (2 pieces) to release.

bizhub PRESS 1250/1250P/1052

11-13

11
(2) As the illustration shows, put both thumbs into [1] (2 positions), then remove the cleaning part [2] while rotating it in the direction indicated by [3]. Important: When removing the cleaning part, rotate it at an angle of about 15 degrees away from the drum.

Replacing ORU-M Units

11.2

To release the stopper of the PCC unit, rotate the PCC unit lock knob [1] at 90 degrees while pulling out.

Slide the PCC unit [1] in the direction indicated by the arrow [2]. Lift up the PCC unit [1] in the direction indicated by the arrow [3], releasing the front side first, and then the rear.

NOTICE
When removing PCC unit, cover the drum surface with sheet of paper in order to prevent scratching to the drum surface.

10

Set the angle of the new PCC unit to the receiver, then fix the unit by sliding to the back.

NOTICE
When fixing PCC unit, please set the back side then set the front side.

NOTICE
Please be careful not to scratch the drum surface. When the PCC unit is installed, remove the paper which was inserted in step 9.

11-14

bizhub PRESS 1250/1250P/1052

11.2

Replacing ORU-M Units

11

11

Rotate the PCC lock knob [1] at 90 degrees to lock it.

NOTICE
Please confirm that the pin has been securely inserted into the PCC unit.

12

Fix the drum cleaner. (1) As the illustration shows, put both thumbs into [1] (2 positions) of the new cleaning part [2], set in fitting , then rotate it in the direction of the drum (indicated by the arrow) [3] to fix it. Important: Be careful not to catch the bundled cables when installing the drum cleaner. Confirm the blade lever [4] has been lowered. If the blade lever [4] has been lifted, perform the following steps to lower the lever. (a) Keep the left side lever of the cleaning part lifted towards the direction indicated by the arrow. Rotate the blade lever [4] all the way down in the direction indicated by the arrow, then release it. Release the left side lever.

(b)

(c)

(2)

Lock the cleaning set levers [1 ](2 pieces). Connect the connector [2]. Fix the wire by the wire saddle [3] (2 pieces). Important: Do not forget to connect the drum cleaner connector.

bizhub PRESS 1250/1250P/1052

11-15

11
13
Install the charging corona unit. (1) Hold the areas [1] and [2] of the charging corona unit [3], then align it into the fitting to install it by fitting and pushing the areas [1] and [2]. Important: Be careful not to catch the bundled cables when installing the charging corona unit.

Replacing ORU-M Units

11.2

(2)

Connect the connectors [1] (2 pieces) and fasten the wire saddle [2]. Important: Do not forget to connect the connectors of the charging corona.

14

Insert the drum part [3] with holding the drum lock levers [1][2], then lock the drum lock levers [1][2] by rotating them in the direction indicated by the arrow.

15

Fix the drum lock knob [1], and tighten it by rotating clockwise.

NOTICE
If the coupling of the drum is sticking out to the front, make sure to push it back in.

11-16

bizhub PRESS 1250/1250P/1052

11.2

Replacing ORU-M Units

11

16

Connect the LPH connectors [1] (2 pieces).

17

Return the intermediate toner hopper [1] to its original position. Set the lock levers [2][3].

NOTICE
Push the PUSH mark on the intermediate toner hopper firmly until it makes a clicking noise and confirm it is locked.

18

Fix the cover of the drum part [1], then tighten the screws [2] (2 pieces) on the right first then the left.

bizhub PRESS 1250/1250P/1052

11-17

11
11.3

Procedure after ORU-M Unit Replacement

11.3

Procedure after ORU-M Unit Replacement


When you finished replacing the ORU-M unit, go on to the following operations.

When the replacement is completed, press [Complete Replacement] on the ORU-M Replacement Unit screen.

The power of the machine will be turned on automatically.

NOTICE
You can return to the replacement procedures again and restart the procedures if the [Continue replacement] button is displayed on the screen. Please use this button if you need to replace other units. Once you start the adjustment procedure, the [Continue replacement] button is not displayed on this screen and you cannot return to the replacement procedures.

11-18

bizhub PRESS 1250/1250P/1052

11.3

Procedure after ORU-M Unit Replacement

11

Install the fusing unit.

(1)

Pull out the ADU drawer and open the reversal output part. Set the fusing unit [3] to the correct position while holding both the front side [1] and the rear side [2] handles. Slide the unit in the direction indicated by the arrow until it reaches the rear side.

(2)

Push the lock screw (purple) [1], then tighten by rotating in the direction indicated by the arrow with a screwdriver.

(3)

Close the reversal output part [1].

bizhub PRESS 1250/1250P/1052

11-19

11
(4)

Procedure after ORU-M Unit Replacement

11.3

Insert the ADU drawer [1], then lock it by lifting the lever M4[2] in the direction indicated by the arrow.

(5)

Close the front door.

Press [Yes].

NOTICE
If a connector of the charging corona, drum cleaner, or LPH is not connected after the PCC is replaced, the Detected disengagement of connector screen will be displayed.

11-20

bizhub PRESS 1250/1250P/1052

11.3

Procedure after ORU-M Unit Replacement

11

(1)

Open the front door, turn the lever M4 down, then press [OK].

The screen notifying you of ORU-M connector disengagement. (2) Press [NG] of the Status field for the disconnected connector.

A detailed screen to show the place of the disconnected connector will be displayed.

bizhub PRESS 1250/1250P/1052

11-21

11
(3)

Procedure after ORU-M Unit Replacement

11.3

Refer to page 11-12 and connect the appropriate connector.

Press [Close] on the sub-screen (4) (5) (6) Lift the lever M4 to lock. Close the front door. Press [Close].

The Register ORU-M Replacement Unit screen is displayed.

Select the name of the replaced unit. % If you have replaced more than one unit, you can select the ones with the same reason to be registered all at once.

11-22

bizhub PRESS 1250/1250P/1052

11.3

Procedure after ORU-M Unit Replacement

11

If the [Replace Reason] button is not displayed in the list of the Register ORU-M Replacement Unit screen, press the checkbox next to the [Unit Name].

The checkmark is displayed. Proceed to step 5. % You can select multiple unit names at one time. You can perform subsequent tasks together by selecting all units you replaced.

NOTICE
Only service engineer can configure not to display the [Replace Reason] button on the Register ORUM Replacement Unit screen. Please contact your service representative, if desired.

4 5

Press the [Replace Reason] button. The dialog to select a reason to replace is displayed. Select a button for replace reason, then press [OK].

bizhub PRESS 1250/1250P/1052

11-23

11
NOTICE

Procedure after ORU-M Unit Replacement

11.3

The replace reason that you selected is displayed in the column of [Replace Reason] button and a checkmark is displayed next to the unit name.

Be sure to select a reason for the replacement. Otherwise, the life cycle counter of the replaced unit will not be reset.

Press [Done].

The dialog box asking to reset the counter of the selected unit is displayed.

Press [Yes].

The life cycle counter of the replaced unit will be reset. % Press [No] to retain the current counter value. The screen to review the life of replace ORU-M units is displayed.

11-24

bizhub PRESS 1250/1250P/1052

11.3

Procedure after ORU-M Unit Replacement

11

Make sure that the life cycle value of the replaced unit has been cleared.

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 10.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed.

bizhub PRESS 1250/1250P/1052

11-25

11
(2)

Procedure after ORU-M Unit Replacement

11.3

Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) (4) Confirm the result of the adjustment by comparing the samples before and after the adjustment. Press [Close].

The ORU-M Replacement Unit screen will be restored.

10

Press [Done].

The Machine Screen will be restored.

11-26

bizhub PRESS 1250/1250P/1052

12

Developing Suction

12.1

Prerequisites for Replacing ORU-M Units

12

12

Developing Suction
When you want to replace an ORU-M unit, switch the machine to the ORU-M mode and follow the procedures on the screen to replace the unit. This document is comprised of the following sections, in order of screen appearance; Prerequisites for Replacing ORU-M Units explains how to switch the machine to the ORU-M mode and prepare for replacement; Replacing ORU-M Units explains the procedures to replace the ORU-M units; and Procedure after ORU-M Unit Replacement explains the procedures to be performed after replacement. You should print this document out and have the hard copy on hand when you start replacement work.

12.1

Prerequisites for Replacing ORU-M Units


In order to start replacing of ORU-M units, follow the following steps to switch the machine to the ORU-M mode.

Press [Utility/Counter]. The Utility screen is displayed.

Press [ORU-M (Unit Replace)].

The screen to agree on the responsibility for the ORU-M operations is displayed. If the ORU-M password is set, the ORU-M Password screen to enter the password is displayed. Proceed to step 4.

bizhub PRESS 1250/1250P/1052

12-3

12
3
If you agree, press [Yes].

Prerequisites for Replacing ORU-M Units

12.1

If you do not agree, press [No]. The Utility screen will be restored.

The ORU-M Replacement Unit screen is displayed. Proceed to step 5.

Enter 4-digit ORU-M password, and then press [OK]. Use half-width alphanumeric characters for the ORU-M password. The half-width alphanumeric characters used for the passwords are case-sensitive. You cannot use symbols and space character.

NOTICE
The ORU-M password is not set initially. If you want to set the ORU-M password, please contact your service representative. The ORU-M password cannot be modified. If you want to modify it, please contact your service representative.

12-4

bizhub PRESS 1250/1250P/1052

12.1

Prerequisites for Replacing ORU-M Units

12

Confirm the units that you replace on the ORU-M Replacement Unit screen. On this screen, units to be replaced are listed in the order from the nearest replacement time. The value of life cycle will be greater than or equal to 100% and highlighted in red if the replacement time limit of the unit exceed its life cycle. The date of last replacement is displayed on the right column of the list. If you want to replace the unit now, proceed to step 8.

NOTICE
Initially, all units are displayed regardless of the need for replacement. You can configure it to display only the units needed to be replaced. You can also modify the threshold to decide whether to display the unit to be replaced or not. Please contact your service representative for details.

Display the replacement procedure guide and check the procedures of the unit replacement. You can confirm the unit replacement procedure before you actually replace them. If you do not need to display the replacement procedure guide, proceed to step 7. (1) Press [Replacement Procedure].

The ORU-M Replacement Procedure screen is displayed.

bizhub PRESS 1250/1250P/1052

12-5

12
(2)

Prerequisites for Replacing ORU-M Units

12.1

Press a button of an unit that you want to replace, and then press [Procedure Guide View].

The replacement guide screen is displayed. (3) In order to move to previous or next page of the guide, press [*][)] at the bottom of the guide screen.

(4)

When you confirm the replacement procedure, press the [Close] button twice.

The ORU-M Replacement Unit screen will be restored.

12-6

bizhub PRESS 1250/1250P/1052

12.1

Prerequisites for Replacing ORU-M Units

12

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 8.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed. (2) Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) Press [Close].

The ORU-M Replacement Unit screen will be restored.

bizhub PRESS 1250/1250P/1052

12-7

12
8
Press [Start Replacement].

Prerequisites for Replacing ORU-M Units

12.1

The screen to confirm the ORU-M unit replacemen is displayed.

Remove the fusing unit before replacing the unit.

NOTICE
Do not press [Yes] before removing the fusing unit.

NOTICE
When you want to replace a fusing unit or a unit other than the fusing cleaning web, make sure to remove the fusing unit when this screen is displayed.

12-8

bizhub PRESS 1250/1250P/1052

12.1

Prerequisites for Replacing ORU-M Units

12

(1)

Open the front door.

(2)

Turn the lever M4 [1] in the direction indicated by the arrow, then pull out the ADU drawer [2].

(3)

Open the reversal output part [1].

(4)

Loosen the lock screw (purple) [1] in the direction (counterclockwise) indicated by the arrow.

(5)

Slide the fusing unit [3] in the direction indicated by the arrow while holding both the front side [1] and the rear side [2] handles, then pull up and remove it. CAUTION Be careful in handling the fusing unit because it may be very hot.

bizhub PRESS 1250/1250P/1052

12-9

12
(6)

Prerequisites for Replacing ORU-M Units

12.1

Close the reversal output part and put the ADU drawer back into place.

NOTICE
Please make sure not lift the lever M4 after returning the ADU drawer to its original position.
Press [Yes].

10

Select a unit to replace. Press [Others], then press [OK].

% To cancel the replacement, press [Cancel] and put the fusing unit back into place. Press [OK].

NOTICE
For the procedure to set the fusing unit, refer to page 12-15.

12-10

bizhub PRESS 1250/1250P/1052

12.1

Prerequisites for Replacing ORU-M Units

12

11

A message to notify you that the machine is being switched to the ORU-M mode.

Make sure that the lever M4 is brought down and Tray 1 and Tray 2 are correctly set, then press [Yes]. For details on how to turn down the lever, refer to step (2) on p.2-8.

12

When replacing units, please refer to page 12-12.

NOTICE
You can confirm the replacement procedure by pressing[Replacement Procedure] on the ORU-M Replacement Unit screen and display the replacement procedure guide during the repleacement work. Please refer to step 6 for details.

bizhub PRESS 1250/1250P/1052

12-11

12
12.2 Replacing ORU-M Units
NOTICE

Replacing ORU-M Units

12.2

You can check the procedure of unit replacement on the screen while you are performing the operation.

NOTICE
The replacement of this unit starts with the fusing unit removed. For details on how to remove the fusing unit, refer to page 12-3.

Loosen the screws [1] (2 pieces), then remove the cover of the drum part [2].

Release the lock [1] and pull out the intermediate toner hopper, then release the lock [2] and open in the direction indicated by the arrow.

Disconnect the LPH connectors [1] (2 pieces).

Slowly rotate the drum lock knob [1] clockwise [2] more than one revolution in order to remove the toner on the drum. Then, firmly rotate the drum lock knob counterclockwise [3] to remove it [1].

12-12

bizhub PRESS 1250/1250P/1052

12.2

Replacing ORU-M Units

12

Turn the left [1] and right [2] lock levers in the direction indicated by the arrow, then pull out the drum part to the front.

Release the developing suction lock [1] by sliding in the direction indicated by the arrow, then remove it.

Fit the rear tab of the new developing suction unit [1] to the guide, then push the front side of the developing suction unit [1] to fix and lock it.

NOTICE
Be careful not to catch the bundled cables when installing the developing suction unit.

Insert the drum part [3] with holding the drum lock levers [1][2], then lock the drum lock levers [1][2] by rotating them in the direction indicated by the arrow.

Fix the drum lock knob [1], and tighten it by rotating clockwise.

NOTICE
If the coupling of the drum is sticking out to the front, make sure to push it back in.

bizhub PRESS 1250/1250P/1052

12-13

12
10
Connect the LPH connectors [1] (2 pieces).

Replacing ORU-M Units

12.2

NOTICE
Do not forget to connect the LPH connectors.

11

Return the intermediate toner hopper [1] to its original position. Set the lock levers [2][3].

NOTICE
Push the PUSH mark on the intermediate toner hopper firmly until it makes a clicking noise and confirm it is locked.

12

Fix the cover of the drum part [1], then tighten the screws [2] (2 pieces) on the right first then the left

12-14

bizhub PRESS 1250/1250P/1052

12.3

Procedure after ORU-M Unit Replacement

12

12.3

Procedure after ORU-M Unit Replacement


When you finished replacing the ORU-M unit, go on to the following operations.

When the replacement is completed, press [Complete Replacement] on the ORU-M Replacement Unit screen.

The power of the machine will be turned on automatically.

NOTICE
You can return to the replacement procedures again and restart the procedures if the [Continue replacement] button is displayed on the screen. Please use this button if you need to replace other units. Once you start the adjustment procedure, the [Continue replacement] button is not displayed on this screen and you cannot return to the replacement procedures.

bizhub PRESS 1250/1250P/1052

12-15

12
2
Install the fusing unit.

Procedure after ORU-M Unit Replacement

12.3

(1)

Pull out the ADU drawer and open the reversal output part. Set the fusing unit [3] to the correct position while holding both the front side [1] and the rear side [2] handles. Slide the unit in the direction indicated by the arrow until it reaches the rear side.

(2)

Push the lock screw (purple) [1], then tighten by rotating in the direction indicated by the arrow with a screwdriver.

(3)

Close the reversal output part [1].

12-16

bizhub PRESS 1250/1250P/1052

12.3

Procedure after ORU-M Unit Replacement

12

(4)

Insert the ADU drawer [1], then lock it by lifting the lever M4[2] in the direction indicated by the arrow.

(5)

Close the front door.

Press [Yes].

NOTICE
If a LPH connector is not connected, the Detected disengagement of connector screen will be displayed.

bizhub PRESS 1250/1250P/1052

12-17

12
(1)

Procedure after ORU-M Unit Replacement

12.3

Open the front door, turn the lever M4 down, then press [OK].

The screen notifying you of ORU-M connector disengagement. (2) Press [NG] of the Status field for the disconnected connector.

A detailed screen to show the place of the disconnected connector will be displayed.

12-18

bizhub PRESS 1250/1250P/1052

12.3

Procedure after ORU-M Unit Replacement

12

(3)

Refer to page 12-12 and connect the appropriate connector.

Press [Close] on the sub-screen (4) (5) (6) Lift the lever M4 to lock. Close the front door. Press [Close].

The Register ORU-M Replacement Unit screen is displayed.

Select the name of the replaced unit. % If you have replaced more than one unit, you can select the ones with the same reason to be registered all at once.

bizhub PRESS 1250/1250P/1052

12-19

12

Procedure after ORU-M Unit Replacement

12.3

If the [Replace Reason] button is not displayed in the list of the Register ORU-M Replacement Unit screen, press the checkbox next to the [Unit Name].

The checkmark is displayed. Proceed to step 5. % You can select multiple unit names at one time. You can perform subsequent tasks together by selecting all units you replaced.

NOTICE
Only service engineer can configure not to display the [Replace Reason] button on the Register ORUM Replacement Unit screen. Please contact your service representative, if desired.

4 5

Press the [Replace Reason] button. The dialog to select a reason to replace is displayed. Select a button for replace reason, then press [OK].

The replace reason that you selected is displayed in the column of [Replace Reason] button and a checkmark is displayed next to the unit name.

12-20

bizhub PRESS 1250/1250P/1052

12.3

Procedure after ORU-M Unit Replacement

12

NOTICE
Be sure to select a reason for the replacement. Otherwise, the life cycle counter of the replaced unit will not be reset.

Press [Done].

The dialog box asking to reset the counter of the selected unit is displayed.

Press [Yes].

The life cycle counter of the replaced unit will be reset. % Press [No] to retain the current counter value. The screen to review the life of replace ORU-M units is displayed.

bizhub PRESS 1250/1250P/1052

12-21

12
8

Procedure after ORU-M Unit Replacement Make sure that the life cycle value of the replaced unit has been cleared.

12.3

Print a sample image. If you do not need to print a sample image, or the [Print Mode] button is not displayed on the ORU-M Peplacement Unit screen, proceed to step 10.

NOTICE
You can configure not to display the [Print Mode] on the ORU-M Replacement Unit screen. Please contact your service representative, if desired.
(1) Press [Print Mode].

The PRINT MODE screen is displayed.

12-22

bizhub PRESS 1250/1250P/1052

12.3

Procedure after ORU-M Unit Replacement

12

(2)

Select a paper that is larger than A4, and press START on the control panel.

The sample image will be output on the specified paper. (3) (4) Confirm the result of the adjustment by comparing the samples before and after the adjustment. Press [Close].

The ORU-M Replacement Unit screen will be restored.

10

Press [Done].

The Machine Screen will be restored.

bizhub PRESS 1250/1250P/1052

12-23

12

Procedure after ORU-M Unit Replacement

12.3

12-24

bizhub PRESS 1250/1250P/1052