The BTS3012 signal flow is associated with the traffic and signaling of the BTS. The BTS3012
signal flow consists of the DL traffic signal flow, UL traffic signal flow, signaling processing
signal flow, and signal flow for cabinet groups.
Um
9
DDPU/DFCU/DFCB
MS Antenna 8 8
system D
T
R
U
7
DTRB
5
6
ECMB
5 5 4
D D D D
T C T C
R S M C
U U U U
3
DCTB
2
D Abis
E 1
L
C
BSC
5. On receiving the signals, the DTMU converts the E1 signals through the data bus (DBUS).
The DTMU also assigns the data based on the data configuration on the OML. Then, the
signals are sent to the DCSU and the DTRUs in DTRU subrack 0 through the ECMB.
6. The DCSU sends the signals to the DTRB in DTRU subrack 1 through the signal cable
between the DCSU and the DTRB.
7. The DTRB sends the signals to the DTRUs in DTRU subrack 1.
8. After receiving the signals, the DTRUs in the two DTRU subracks perform digital filtering,
up conversion, and filter amplification, and then send the signals to the DDPU (DFCU or
DFCB).
9. The duplexer in the DDPU (DFCU or DFCB) filters the signals from the DTRU, and then
transmits the signals through the antenna subsystem.
Um
1
DDPU/DFCU/DFCB
MS Antenna
system 2 2
D
T
R
U
3
DTRB
5
4
ECMB
5 5 6
D D D D
T C T C
R S M C
U U U U
7
DCTB
8
D Abis
E 9
L
C
BSC
6. The DTMU backs up the E1 signals and converts the E1 signals through the DBUS on the
DCMB. The DTMU then sends the converted signals to the DCCU through the ECMB.
7. The DCCU sends the signals to the DCTB through the TOP signal cable connecting the
DCTB with the DCCU (or DSCU).
8. The DCTB sends the signals to the DELC.
9. The DELC provides lightning protection for the signals. Then, it sends the signals to the
BSC through the E1 cables.
BTS3012/BTS3012AE cabinet
Abis
DTMU DTRU
BSC DDPU/
DFCU/
DFCB
1. The BSC sends the signaling data to the DTMU of the BTS.
2. After processing the signaling, the DTMU sends the signaling to the DTRU and DDPU
(DFCU or DFCB).
3. The DTRU and DDPU (DFCU or DFCB) report their board status to the DTMU.
4. The DTMU obtains the status of the BTS3012 by collecting and analyzing the states of all
the boards. Then, it transmits the information to the BSC through the Abis interface.
Figure 11-4 shows the bus connection between BTS3012 cabinet groups.
Control cable
Cabinet Cabinet in the
in the main Clock cable extension
cabinet group cabinet group
NOTE
The main cabinet group and extension cabinet group are specified by the DIP switches on the DCSU. For
details on setting the DIP switches, refer to DIP Switches on the DCSU (for 18 TRXs).
Clock Signals
For details on the clock signal flow, refer to 10 Synchronization of the BTS3012 Clock .
Control Signals
The control signals refer to the CBUS1 signals, which are responsible for the communication
between the DTMUs in the main and extension cabinet groups.
Cabinet
in the main cabinet group DCCU
DCSU
NOTE
The DCTB shown in Figure 11-5 is the backplane on top of the BTS3012 cabinet.