Operating principle
Safety modules XPS AC are used for monitoring Emergency stop circuits conforming
to standards EN/ISO 13850 and EN 60204-1 and also meet the safety requirements
for the electrical monitoring of switches in protection devices conforming to standard
EN 1088/ISO 14119. They provide protection for both the machine operator and the
machine by immediately stopping the dangerous movement on receipt of a stop
instruction from the operator, or on detection of a fault in the safety circuit itself.
To aid diagnostics, the modules have LEDs which provide information on the
monitoring circuit status.
The XPS AC module has 3 safety outputs and a solid-state output for signalling to
the PLC.
Characteristics
Module type XPS AC XPS ACppppP
Product designed for max. use in safety related parts of Category 3 max.
control systems (conforming to EN 954-1/ISO 13849-1)
Conformity to standards EN 60204-1, EN 1088/ISO 14119, EN/ISO 13850, EN/IEC 60947-1 + A11,
EN/IEC 60947-5-1
Product certifications UL, CSA, BG
Connections: Dimensions:
page 38770-EN/4 page 38730-EN/2
2 38770-EN_Ver11.1.indd
Characteristics (continued), Safety automation system solutions 0
Characteristics
Module type XPS AC XPS ACppppP
Connection Type Captive screw clamp terminals Captive screw clamp terminals, removable
terminal block
1-wire Without cable end Solid or flexible cable: 0.14…2.5 mm2 Solid or flexible cable: 0.2…2.5 mm2
connection
With cable end Without bezel, flexible cable: 0.25…2.5 mm2
With bezel, flexible cable: 0.25…1.5 mm2 With bezel, flexible cable: 0.25…2.5 mm2
2-wire Without cable end Solid or flexible cable: 0.14…0.75 mm2 Solid cable: 0.2…1 mm2,
connection flexible cable: 0.2…1.5 mm2
With cable end Without bezel, flexible cable: 0.25…1 mm2
References
Description Type of Number of Additional Supply Reference Weight
terminal instantaneous outputs
block opening safety
connection circuits kg
Safety modules for Integrated in 3 1 solid-state a and c 24 V XPS AC5121 0.160
Emergency stop and module
switch monitoring
a 48 V XPS AC1321 0.210
Connections: Dimensions:
page 38770-EN/4 page 38730-EN/2
38770-EN_Ver11.1.indd 3
Connections Safety automation system solutions 0
XPS AC
Module XPS AC associated with an Emergency stop button with 1 N/C contact
F1
S2
Start
S1 ESC
A1 Y1 Y2 13 23 33 Y43
XPS AC
Logic K1
T
K2
48 V, 115 V, 230 V K1 K2
A2 PE 14 24 34 Y44
To PLC
F1
S2
Start K3
S1
K4
ESC
A1 Y1 Y2 13 23 33 Y43
XPS AC
Logic K1 K3 K3 K3
T
K2 K4 K4 K4
48 V, 115 V 230 V K1 K2
A2 PE 14 24 34 Y44
To PLC
K3 K4
4 38770-EN_Ver11.1.indd
Connections (continued) Safety automation system solutions 0
XPS AC
Functional diagram of module XPS AC
LED details
1
2