Вы находитесь на странице: 1из 121

ZXMW-PR10 (V3.

2) Digital Microwave System

User s Manual

ZTE CORPORATION

ZXMW-PR10 Digital Microwave System User s Manual

Manual Version 20060516-R1.0 Product Version V3.2

Copyright " 2004 ZTE Corporation All rights reserved. No part of this documentation may be excerpted, reproduced, translated, annotated or duplicated, in any form or by any means without the prior written permission of ZTE Corporation.

ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China Website: http://www.zte.com.cn Postcode: 518057 Customer Support Center: (+86 755) 2677 1900 Fax: (+86 755) 2677 0801 Email: support@zte.com.cn * * * * 800-9830-9830

Suggestions and Feedback


To improve the quality of ZTE product documentation and offer better services to our customers, we hope you can give us your suggestions and comments on our documentation and fax this form to +86-755-26770160; or mail to Marketing center 3rd floor ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China!. Our postcode is 518057.

Document name Product version

ZXMW-PR10 Digital Microwave System User #s Manual


V2.0 Document version 20041206-R1.0

Equipment installation time Your information Name Postcode Telephone Presentation: Good Your evaluation of this documentation Company Company address E-mail How is information presented? (Introductions, procedures, illustrations, others) Fair Average Poor Bad

Accessibility: Can you find the information you want? (Table of contents, Index, headings, numbering, others) Good Fair Average Poor Bad

Intelligibility: Can you understand it when you find it? (Language, vocabulary, readability, others) Good Presentation: Your suggestions for improvement of this documentation Intelligibility: Fair Average Poor Bad

Accessibility:

Your other suggestions on ZTE product documentation

Contents
1 DECLARATION OF CONFORMITY.................................................................................................... 1 2 FIRST AID FOR ELECTRICAL SHOCK AND SAFETY RULES..................................................... 2 2.1 FIRST AID FOR ELECTRICAL SHOCK ....................................................................................... 2 2.1.1 Artificial Respiration.............................................................................................................. 2 2.1.2 Treatment of Burns ................................................................................................................ 2 2.2 SAFETY RULES.............................................................................................................................. 4 3 PURPOSE AND STRUCTURE OF THE MANUAL............................................................................. 6 3.1 PURPOSE OF THE MANUAL........................................................................................................ 6 3.2 AUDIENCE BASIC KNOWLEDGE ............................................................................................... 6 3.3 STRUCTURE OF THE MANUAL.................................................................................................. 6 4 ABBREVIATION LIST ............................................................................................................................ 8 4.1 LIST OF ABBREVIATIONS............................................................................................................ 8 5 SYSTEM PRESENTATION................................................................................................................... 10 5.1 RADIO SYSTEM OVERVIEW ..................................................................................................... 10 5.1.1 General................................................................................................................................. 10 5.2 COMPLIANCE WITH INTERNATIONAL STANDARDS .......................................................... 10 5.3 APPLICATIONS............................................................................................................................. 10 5.4 SYSTEM ARCHITECTURE.......................................................................................................... 10 5.4.1 IDU ...................................................................................................................................... 11 5.4.2 ODU..................................................................................................................................... 11 5.5 MANAGEMENT SYSTEMS......................................................................................................... 11 5.5.1 Management Ports ............................................................................................................... 12 5.5.2 Protocols .............................................................................................................................. 12

-i-

6 EQUIPMENT TECHNICAL SPECIFICATIONS................................................................................15 6.1 TECHNICAL SPECIFICATION.....................................................................................................15 7 CHARACTERISTICS OF THE INDOOR UNIT .................................................................................24 7.1 GENERAL ......................................................................................................................................24 7.2 TRIBUTARY INTERFACE ............................................................................................................24 7.2.1 2-Mbit/s Interface .................................................................................................................24 7.2.2 Ethernet Interface (Optional)................................................................................................25 7.3 SERVICE CHANNEL INTERFACE ..............................................................................................25 7.3.1 64-kbit/s Contra-Directional Interface E0 (Optional)...........................................................25 7.3.2 EDI Interface (Optional).......................................................................................................25 7.3.3 EOW Interface (Optional) ....................................................................................................25 7.3.4 Network Management Interface ...........................................................................................25 7.4 MODULATOR / DEMODULATOR...............................................................................................26 7.5 CABLE INTERFACE .....................................................................................................................26 7.6 AVAILABLE LOOPS......................................................................................................................26 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES......................................................27 8.1 1+0/1+1 IDU VERSIONS ...............................................................................................................27 8.1.1 Line Interface........................................................................................................................27 8.1.2 Radio Interface .....................................................................................................................28 8.1.3 Equipment Controller ...........................................................................................................30 8.2 IDU LOOPS ....................................................................................................................................30 8.2.1 Tributary Loop......................................................................................................................30 8.2.2 Baseband Unit Loop .............................................................................................................31 8.2.3 IDU Loop..............................................................................................................................31 9 CHARACTERISTICS OF THE OUTDOOR UNIT.............................................................................40 9.1 GENERAL ......................................................................................................................................40

- ii -

9.2 TECHNICAL SPECIFICATIONS.................................................................................................. 40 10 DESCRIPTION OF THE OUTDOOR UNIT ..................................................................................... 45 10.1 GENERAL.................................................................................................................................... 45 10.2 TRANSMIT SECTION ................................................................................................................ 45 10.3 RECEIVE SECTION.................................................................................................................... 46 10.4 CABLE INTERFACE................................................................................................................... 46 10.5 ATPC OPERATION...................................................................................................................... 46 10.6 1+1 Tx SYSTEM .......................................................................................................................... 47 10.7 POWER SUPPLY ......................................................................................................................... 48 11 INSTALLATION AND PROCEDURES FOR ENSURING ELECTROMAGNETIC

COMPATIBILITY ..................................................................................................................................... 53 11.1 GENERAL.................................................................................................................................... 53 11.2 MECHANICAL INSTALLATION............................................................................................... 53 11.2.1 IDU Installation.................................................................................................................. 53 11.3 ELECTRICAL WIRING............................................................................................................... 53 11.4 GROUNDING CONNECTION.................................................................................................... 54 12 USER CONNECTIONS ........................................................................................................................ 55 12.1 CONNECTOR USE FOR 1+0/1+1 STANDARD VERSION...................................................... 55 12.2 STANDARD VERSION CONNECTORS ................................................................................... 56 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA ............. 58 13.1 INSTALLATION KIT................................................................................................................... 58 13.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)...................................................... 59 13.3 INSTALLATION PROCEDURE.................................................................................................. 59 13.4 GROUNDING .............................................................................................................................. 61 14 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA............ 71

- iii -

14.1 INSTALLATION KIT ...................................................................................................................71 14.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) ......................................................71 14.3 INSTALLATION PROCEDURE ..................................................................................................71 14.4 GROUNDING...............................................................................................................................74 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA ...........82 15.1 FOREWORD.................................................................................................................................82 15.2 INSTALLATION KIT ...................................................................................................................82 15.3 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) ......................................................82 15.4 INSTALLATION PROCEDURE ..................................................................................................83 15.4.1 Installation onto the pole of the support system and the antenna .......................................83 15.4.2 Installation of ODU ............................................................................................................84 15.4.3 ODU installation.................................................................................................................85 15.5 ANTENNA AIMING.....................................................................................................................85 15.6 COMPATIBILITY.........................................................................................................................86 15.7 GROUNDING...............................................................................................................................86 16 LINE-UP OF THE RADIO HOP........................................................................................................104 16.1 LINE-UP OF THE RADIO HOP ................................................................................................104 16.1.1 Antenna alignment and received field measurement ........................................................104 16.1.2 Network element configuration ........................................................................................104 16.1.3 Radio Checks....................................................................................................................104 17 PERIODICAL CHECKS.....................................................................................................................106 17.1 GENERAL ..................................................................................................................................106 17.2 CHECKS TO BE CARRIED OUT .............................................................................................106 18 COMPOSITION OF THE INDOOR UNIT.......................................................................................107 18.1 GENERAL ..................................................................................................................................107 19 COMPOSITION OF OUTDOOR UNIT............................................................................................108

- iv -

19.1 GENERAL.................................................................................................................................. 108

-v-

Chapter 1 DECLARATION OF CONFORMITY

1 DECLARATION OF CONFORMITY
ZTE Corporation declares that the products: Digital radio relay system Digital radio relay system Digital radio relay system Digital radio relay system Digital radio relay system Digital radio relay system Digital radio relay system Digital radio relay system Digital radio relay system Digital radio relay system 7 GHz 8 GHz 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 25 GHz 28 GHz 38 GHz

comply with the essential requirements of article 3 of the R&TTE Directive (1999/05/EC). The following standards apply: EN 60950:200 Safety of information technology equipment!. EN 301 489-4 V.1.3.1 (2002-8): Electromagnetic compatibility and radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 4. Specific conditions for fixed radio links and ancillary equipment and services! ETSI EN 301 751 V.1.1. (2002-12): Fixed Radio Systems; Point-to point equipment and antennas; generic harmonized standard for point-to-point digital fixed radio systems and antennas covering the essential requirements under article 3.2 of the 1999/5/EC Directive!.

-1-

Chapter 2 FIRST AID FOR ELECTRICAL SHOCK AND SAFETY RULES

2 FIRST AID FOR ELECTRICAL SHOCK AND


SAFETY RULES

2.1 FIRST AID FOR ELECTRICAL SHOCK


Do not touch the patient with bare hands until the circuit has been opened. Open the circuit by switching off the line switches. If that is not possible protect yourself with dry material and free the patient from the conductor.

2.1.1 Artificial Respiration


It is important to start mouth resuscitation at once and to call a doctor immediately. suggested procedure for mouth to mouth resuscitation method is described in the Tab. 2.1.

2.1.2 Treatment of Burns


This treatment should be used after the patient has regained consciousness. It can also be employed while artificial respiration is being applied (in this case there should be at least two persons present). Warning Do not attempt to remove clothing from burnt sections Apply dry gauze on the burns Do not apply ointments or other oily substances.

-2-

Chapter 2 FIRST AID FOR ELECTRICAL SHOCK AND SAFETY RULES

Tab. 2.1 Step


1

Description
Lay the patient on his back with his arms parallel to the body. If the patient is laying on an inclined plane, make sure that his stomach is slightly lower than his chest. Open the patients mouth and check that there is no foreign matter in mouth (dentures, chewing gum, etc.). Kneel beside the patient level with his head. Put an hand under the patient"s head and one under his neck. Lift the patient "s head and let it recline backwards as far as possible.

Figure

Shift the hand from the patient "s neck to his chin and his mouth, the index along his jawbone, and keep the other fingers closed together. While performing these operations take a good supply of oxygen by taking deep breaths with your mouth open.

With your thumb between the patient"s chin and mouth keep his lips together and blow into his nasal cavities

While performing these operations observe if the patient "s chest rises. If not it is possible that his nose is blocked: in that case open the patient"s mouth as much as possible by pressing on his chin with your hand, place your lips around his mouth and blow into his oral cavity. Observe if the patient "s chest heaves. This second method can be used instead of the first even when the patient"s nose is not obstructed, provided his nose is kept closed by pressing the nostrils together using the hand you were holding his head with. The patient "s head must be kept sloping backwards as much as possible. Start with ten rapid expirations, hence continue at a rate of twelve/fifteen expirations per minute. Go on like this until the patient has regained conscious-ness, or until a doctor has ascertained his death.

-3-

Chapter 2 FIRST AID FOR ELECTRICAL SHOCK AND SAFETY RULES

2.2 SAFETY RULES


When the equipment units are provided with the plate, shown in Fig. 2.1, it means that they contain components electrostatic charge sensitive.

Fig. 2.1

In order to prevent the units from being damaged while handling, it is advisable to wear an elasticised band (Fig. 2.2) around the wrist ground connected through coiled cord (Fig. 2.3).

Fig. 2.2

Fig. 2.3

-4-

Chapter 2 FIRST AID FOR ELECTRICAL SHOCK AND SAFETY RULES

The units showing the label, shown in Fig. 2.4, include laser diodes and the emitted power can be dangerous for eyes; avoid exposure in the direction of optical signal emission.

Fig. 2.4

-5-

Chapter 3 PURPOSE AND STRUCTURE OF THE MANUAL

3 PURPOSE AND STRUCTURE OF THE MANUAL


3.1 PURPOSE OF THE MANUAL
The purpose of this manual consists in providing the user with information which allows to operate and maintain the ZXM-PR10 radio family. Warning: This manual does not include information relevant to the CIT-WEB management program windows and relevant application. They will provided by the CIT-WEB operation manual.

3.2 AUDIENCE BASIC KNOWLEDGE


The following knowledge and skills are required to operate the equipment: a basic understanding of microwave transmission installation and maintenance experience on digital radio system a good knowledge of IP/OSI networks and routing policy.

3.3 STRUCTURE OF THE MANUAL


The manual is subdivided into sections each of them developing a specific topic entitling the section. Each section consists of a set of chapters, enlarging the main subject master.

Section 1 - User Guide It provides the information about the main safety rules and expounds the purpose and the structure of the manual.

Section 2 - Description and specifications It traces the broad line of equipment operation and lists the main technical characteristics of the whole equipment and units it consists of. List of abbreviation meaning is also supplied.

Section 3 - Installation The mechanical installation procedures are herein set down as well as the user electrical connections. The content of the tool kit (if supplied) is also listed.

Section 4 - Line-Up Line-up procedures are described as well as checks to be carried out for the equipment correct operation. The list of the instruments to be used and their characteristics are also set down.

-6-

Chapter 3 PURPOSE AND STRUCTURE OF THE MANUAL

Section 5 - Maintenance The routine maintenance actions are described as well as fault location procedures in order to identify the faulty unit and to re-establish the operation after its replacement with a spare one. Section 6 - Programming and supervision The ZXMW-PR10 radio family is programmed and supervised using different software tools. Some of them are already available, some other will be available in the future. This section lists the tools implemented and indicates if descriptions are already available. Each description of software tools is supplied in a separated manual.

Section 7 - Composition Position, part numbers of the components the equipment consist of, are shown in this section.

-7-

Chapter 4 ABBREVIATION LIST

4 ABBREVIATION LIST
4.1 LIST OF ABBREVIATIONS
AIS ATPC BB BBER BER CIT CU DSCP DSP EMC/EMI EOC EOW ESD FEC FEM FU HDLC IDU IF LAN LOF LOS MAC MIB MMIC MTBF MU NE ODU OSI PDH PPI PPP RIM SNMP SU TCP/IP VLAN Alarm Indication Signal Automaric Transmit Power Control Baseband Background Block Error Radio Bit Error Rate Craft Interface Terminal Core Unit Differentiated Service Code Point Digital Signal Processing Electromagnetic Compatibility/Electromagnetic Interference Embedded Overhead Channel Engineering Orderwire Electrostatic Discharge Forward Error Corrector Fast Ethernet Module Fan Unit High Level Data Link Control Indoor Unit Intermediate Frequency Local Area Network Loss Of Frame Loss Of Signal Media Access Control Management Information Base Monolitic Microwave Integrated Circuit Mean Time Between Failure Modem Unit Network Element Outdoor Unit Open System Interconnection Plesiochronous Digital Hierarchy Plesiochronous Physical Interface Point to Point Protocol Radio Interface Module Simple Network Management Protocol Service Unit Transmission Control Protocol/Internet Protocol Virtual LAN

-8-

Chapter 4 ABBREVIATION LIST

-9-

Chapter 5 SYSTEM PRESENTATION

5 SYSTEM PRESENTATION
5.1 RADIO SYSTEM OVERVIEW
5.1.1 General
ZXMW PR10 (V3.2) Digital Microwave System is ZTE "s new PDH radio series for low-to-medium transmission capacities in frequency bands from 7 to 38 GHz. Different hardware versions offer a range of transmission capacities from 2xE1 to 16xE1, on QPSK and 16QAM modulation. Reduced cost, high reliability, compact size, light weight and full programmability are the key features of this radio series.

5.2 COMPLIANCE WITH INTERNATIONAL STANDARDS


The equipment complies with the following international standards: EN 301 489-4 for EMC ITU-R recommendations for all frequency bands EN 300 132-2 characteristics for power supply EN 300 019 environmental characteristics (Operation class 3.2 for IDU and class 4.1 for ODU; storage: class 1.2; transport: class 2.3) EN 60950 for safety

5.3 APPLICATIONS
ZXMW PR10 main applications are: Radio communication between GSM/CDMA cells Radio links for voice and data transmission Spur routes for high capacity radio system Emergency links

5.4 SYSTEM ARCHITECTURE


The ZXMW PR10 radio series consists of two separate units: The indoor unit (IDU) that houses tributary interfaces, modem and controller units The outdoor unit (ODU) that converts IF signals into RF signals and vice versa.

The two units are interconnected via coaxial cable. Fig. 5.1 and Fig. 5.2 show a typical IDU/ODU layout whereas Fig. 5.3 and Fig. 5.4 show the radio block diagram in 1+0 and 1+1 configuration respectively.

- 10 -

Chapter 5 SYSTEM PRESENTATION

5.4.1 IDU
The IDU is available in the following hardware versions: 1 rack unit compact IDU, 1+0 configuration, 2/4/8xE1 1 rack unit compact IDU, 1+0 configuration, 2/4/8/16xE1 1 rack unit compact IDU, 1+1 configuration, 2/4/8/16xE1 1 rack unit compact IDU, 1+1 configuration, 2/4/8/16xE1

IDUs consist of two main units plugged into a 1-U cabinet. Core Unit consisting of an integrated traffic interface module (TIM) for up to 16 E1/DS1 channels, room for an optionally plugged traffic interface module (TIM), room for an optionally plugged service interface module (SIM), a service multiplexer for service individual multiplexing/demultiplexing, a radio inter-working function for adaptation of the signals to the modem format, a radio protection switching function (RPS) to switch between two receive paths; a micro-controller. Modem Unit consisting of a power supply, the digital modulator/demodulator and the conversion to and from an analogue intermediate frequency. In protected terminal configurations two identical Modem Units shall be present in the IDU. Line interfaces house tributary connections and, through a multiplexing/demultiplexing and bit insertion/extraction process, supply/receive the aggregate signal to/from the modulator/demodulator. Line interfaces carry out the digital processing for the QPSK/16QAM modulator and, in 1+1 configuration, duplicate the main signals on the transmission side and perform the changeover on the receive side. Interfaces towards the ODU house the cable interface for bidirectional communication between ODU and IDU, and implement the IF section of the mo-demodulator. IDU power supply units process battery voltage and supply power to IDU and ODU circuits. The controller section of the radio houses service channels interfaces, stores IDU firmware, interfaces ZTE management systems though dedicated supervision ports, and routes external and internal alarms to relay contacts.

5.4.2 ODU
The ODU houses the interface towards the IDU on one side, and towards the antenna flange on the other. The ODU shifts the incoming QPSK/16QAM-modulated carrier to RF frequency through a double conversion. The opposite occurs at the receive side, when the IF-conevrted carrier is sent to the IDU demodulator. In 1+1 versions two electromechanical switches connect the transmitter in service to the antenna, and put in stand-by the other transmitter. Antenna coupling in 1+1 systems is done through a balanced or unbalanced hybrid.

5.5 MANAGEMENT SYSTEMS


ZXMW PR10 can be controlled locally and remotely via ZTE supervision software: CIT-WEB: a ZTE" proprietary software utility for monitoring and controlling the operation and configuration of the PR10 radios. Located on the PR10 Controller, any of the two LAN ports allows for connecting a PC running the CIT-WEB server that is embedded in the radio. This web server stores HTML pages and applets that provide a user interface for monitoring and controlling any PR10 Network Element, using the Microsoft Internet Explorer, version 5.5 and later.

- 11 -

Chapter 5 SYSTEM PRESENTATION

ZXMW EMS: a Windows-based

management system for networks (up to 500 NE)

These systems provide a friendly graphic interface complying with current standard use of keyboards, mouse and windows.

5.5.1 Management Ports


ZXMW PR10 radio terminals connect to the supervision network via the following communication ports: Ethernet 10/100 BaseT Port

5.5.2 Protocols
SNMP along with IP or OSI protocol stacks are used to manage ZXMW PR10 operation.

Fig. 5.1 1+1 ODU typical configuration with integrated antenna


1+1 ODU typical configuration with integrated antenna

Fig. 5.2 1+1 IDU Typical Configuration # 2x2, 4x2, 8x2, 16x2 Mbit/s

- 12 -

Chapter 5 SYSTEM PRESENTATION

Fig. 5.3 1+1 Equipment Block Diagram

- 13 -

Chapter 5 SYSTEM PRESENTATION

Fig. 5.4 1+0 Non-Expandable Equipment Block Diagram

- 14 -

Chapter 6 EQUIPMENT TECHNICAL SPECIFICATIONS

6 EQUIPMENT TECHNICAL SPECIFICATIONS


6.1 TECHNICAL SPECIFICATION
Frequency range 7 GHz 8 GHz 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 25 GHz 28 GHz 38 GHz RF channel arrangement
-

7.11 to 7.7 GHz 7.7 to 8.5 GHz 10.7 to 11.7 GHz 12.75 to 13.25 GHz 14.4 to 15.35 GHz 17.7 to 19.7 GHz 21.2 to 23.6 GHz 24.5 to 26.5 GHz 27.5 to 29.5 GHz 37 to 39.5 GHz ITU-R Rec F.385 ITU-R Rec F.386 ITU-R Rec F.497 ITU-R Rec F.636 ITU-R Rec F.595 ERC/T/R 13-02 Annex A or ITU-R Rec F.637 ERC/T/R 13-02 Annex B ERC/T/R 13-02 Annex C ITU-R Rec F.749

7 GHz 8 GHz 13 GHz 15 GHz 18 GHz 23 GHz 25 GHz 28 GHz 38 GHz

- 15 -

Chapter 6 EQUIPMENT TECHNICAL SPECIFICATIONS

Go-return frequency 7 GHz 8 GHz 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 25 GHz 28 GHz 38 GHz -

245/196/168/161 MHz 311.32 MHz 530 MHz 266 MHz 728 MHz 1010 MHz 1008 MHz 1008 MHz 1008 MHz 1260 MHz

Transmission capacity Main signal from 2 to 16x2 Mbit/s

see Tab. 6.1 Tab. 6.1 Signal capacity from 2x2 up to 16x2 Mbit/s Capacity (Mbit/s)
2x2/4x2/8x2/16x2 2x2/4x2/8x2/16x2

Configuration
1+0 1+1

Mechanical dimension
1 unit high 1 unit high

Service channel capacity The following service channel is available: 1+0/1+1 standard - 2x2, 4x2, 8x2, 16x2 Mbit/s version (1 standard unit) One of the following service channels is available: 64 kbit/s E0 interface 1+0 or 1+1 hot stand-by and 1 antenna, 1+1 frequency diversity on 1 cross polar antenna or two separated antennas 5 ppm; 10 ppm ageing included according to ETSI EN 301 390 QPSK/16QAM

Antenna configuration

Frequency accuracy RF spurious emissions Modulation

- 16 -

Chapter 6 EQUIPMENT TECHNICAL SPECIFICATIONS

Tab. 6.2 Modulation used according to bit rate and RF channel space Modulat. type
QPSK 16QAM

Bit rate (Mbit/s) 2x2


3.5 MHz n.a.

4x2
7 MHz 3.5 MHz

8x2
14 MHz 7 MHz

16x2
28 MHz 14 MHz

Demodulation Output power at the antenna side, 1+0 version Receiver threshold at the antenna side 1+0 version Additional losses both Tx and Rx sides, 1+1 version 4 dB 0.5 dB 1.7 dB (branch1)/7 dB (branch 2)

coherent refer to Tab. 6.3 refer to Tab. 6.4 and Tab. 6.5

version with balanced hybrid version with unbalanced hybrid 1x10


-11

Residual BER Maximum input level for BER 10


-3

-20 dBm

Tab. 6.3 Nominal output power 1 dB tolerance ZXMW PR10


7GHz 8 GHz 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 25 GHz 28 GHz 38 GHz

Output power QPSK


+27 dBm +27 dBm +25 dBm +25 dBm +25 dBm +20 dBm +20 dBm +20 dBm +19 dBm +17 dBm

Output power 16QAM


+22 dBm +22 dBm +20 dBm +20 dBm +20 dBm +15 dBm +15 dBm +15 dBm +14 dBm +13 dBm

- 17 -

Chapter 6 EQUIPMENT TECHNICAL SPECIFICATIONS

Tab. 6.4 Nominal received threshold in 1+0 configuration QPSK PR10


7 8 11 13 15 18 23 25 28 38

16QAM 4x2 2x2 10


-3

2x2 10
-6

4x2 10
-3

10

-3

10

-6

10
-

-6

10

-6

10

-3

-91 dBm -91 dBm -90.5 dBm -90.5 dBm -90.5 dBm -89 dBm -89 dBm -88.5 dBm -88 dBm -87 dBm

-93 dBm -93 dBm -92.5 dBm -92.5 dBm -92.5 dBm -91 dBm -91 dBm -90.5 dBm -90 dBm -89 dBm

-88 dBm -88 dBm -87.5 dBm -87.5 dBm -87.5 dBm -86 dBm -86 dBm -85.5 dBm -85 dBm -84 dBm

-90 dBm -90 dBm -89.5 dBm -89.5 dBm -89.5 dBm -88 dBm -88 dBm -87.5 dBm -87 dBm -87 dBm

-84 dBm -84 dBm -83.5 dBm -83.5 dBm

-86 dBm -85 dBm -85.5 dBm -85.5 dBm -85.5 dBm -85 dBm -84 dBm -83.5 dBm -83 dBm -82 dBm

-83.5 dBm -83 dBm -82 dBm -81.5 dBm -81 dBm -80 dBm

Tab. 6.5 Nominal received threshold in 1+0 configuration QPSK PR10


7 8 11 13 15 18 23 25 28 38

16QAM 16x2 8x2 10-3


-84 dBm -84 dBm -83.5 dBm -83.5 dBm -83.5 dBm -82 dBm -82 dBm -81.5 dBm -81 dBm -80 dBm

8x2 10-6
-85 dBm -85 dBm -84.5 dBm -84.5 dBm -84.5 dBm -83 dBm -83 dBm -82.5 dBm -82 dBm -81 dBm

16x2 10-3
-83 dBm -83 dBm -82.5 dBm -82.5 dBm -82.5 dBm -81 dBm -81 dBm -80.5 dBm -80 dBm -79 dBm

10-3
-87 dBm -87 dBm -86.5 dBm -86.5 dBm -86.5 dBm -85 dBm -85 dBm -84.5 dBm -84 dBm -83 dBm

10-6
-82 dBm -82 dBm -81.5 dBm -81.5 dBm -81.5 dBm -80 dBm -80 dBm -79.5 dBm -79 dBm -78 dBm

10-6
-81 dBm -81 dBm -80.5 dBm -80.5 dBm -80.5 dBm -79 dBm -79 dBm -78.5 dBm -78 dBm -77 dBm

10-6
-78 dBm -78 dBm -77.5 dBm -77.5 dBm -77.5 dBm -76 dBm -76 dBm -75.5 dBm -75 dBm -74 dBm

10-3
-80 dBm -80 dBm -79.5 dBm -79.5 dBm -79.5 dBm -78 dBm -78 dBm -77.5 dBm -77 dBm -76 dBm

- 18 -

Chapter 6 EQUIPMENT TECHNICAL SPECIFICATIONS

Power supply Power voltage supply -40.8 to -57.6 Vdc

Power consumption Fully equipped terminal with 370 m 1/4! IDU-ODU cable.

Tab. 6.6 Guaranteed power consumption f15 GHz -40.8 a -57.6 Vdc
46 Watts 70 Watts

Configuration

Nominal Power Consumption f15 GHz -48 Vdc


44 Watts 66 Watts

Guaranteed power consumption f>15 GHz -40.8 a -57.6 Vdc


39 Watts 58 Watts

Nominal Power Consumption f>15 GHz -48 Vdc


37 Watts 54 Watts

1+0 1+1

IDU only consumption

Tab. 6.7 Guaranteed consumption f15 GHz -40.8 a -57.6 Vdc


25 Watts

IDU type
1+0 configuration

Nominal Consumption f15 GHz -48 Vdc


24 Watts

Environmental conditions
-

Operational range for IDU Operational range for ODU Survival temperature range for IDU Survival temperature range for ODU Operational humidity for IDU Operational humidity for ODU Heat dissipation of ODU

-5 C to +45 C -33 C to +55 C -10 C to +55 C -40 C to +60 C 95% at +35 C weather proof according to IP65 environmental class Thermal resistance 0.5 C/W Solar heat gain: not exceeding 5 C 260 Km/h refer to Tab. 6.8

Wind load Mechanical characteristics


-

Dimensions

- 19 -

Chapter 6 EQUIPMENT TECHNICAL SPECIFICATIONS

Tab. 6.8 IDU/ODU Dimensions Width (mm)


ODU 1+0 version ODU 1+1 version IDU 1+0/1+1 250 278 482

Height (mm)
250 255 44

Depth (mm)
100 280 240

Weight refer to Tab. 6.9

Tab. 6.9 IDU/ODU Weights


ODU 1+0 ODU 1+1 IDU 1+0/1+1 Panning system 1+0/1+1 4.5 kg 13.3 kg 3.5/3.7 4.4 kg kg

Mechanical Layout refer to typical Fig. 6.1, Fig. 6.2.

Fig. 6.1 IDU 1+0 Standard (2x2/4x2/8x2/16x2 Mbit/s)

Fig. 6.2 IDU 1+1 Standard (2x2/4x2/8x2/16x2 Mbit/s)

- 20 -

Chapter 6 EQUIPMENT TECHNICAL SPECIFICATIONS

Fig. 6.3 1+0 ODU With Separated Antenna (Pole Mounting)

Fig. 6.4 1+1 ODU With Separated Antenna

- 21 -

Chapter 6 EQUIPMENT TECHNICAL SPECIFICATIONS

Fig. 6.5 1+0 ODU With Integral Antenna (Pole Mounting)

Fig. 6.6 1+1 ODU With Integral Antenna (Pole Mounting)

- 22 -

Chapter 6 EQUIPMENT TECHNICAL SPECIFICATIONS

Fig. 6.7 1+1 ODU With Separated Antenna (Wall Mounting)

- 23 -

Chapter 7 CHARACTERISTICS OF THE INDOOR UNIT

7 CHARACTERISTICS OF THE INDOOR UNIT


7.1 GENERAL
The C. following IDU characteristics are guaranteed for the temperature range from -5 C to +45

7.2 TRIBUTARY INTERFACE


7.2.1 2-Mbit/s Interface
Input side Bit rate Line code Rated impedance Rated level Return loss 2048 kbit/s 50 ppm HDB3 75 Ohm or 120 Ohm 2.37 Vp/75 Ohm or 3 Vp/120 Ohm 12 dB from 57 kHz to 102 kHz 18 dB from 102 kHz to 2048 kHz 14 dB from 2048 kHz to 3072 kHz 6 dB according to f trend see mask in Table 2, ITU-T. G.823 see mask in Figure 1, ITU-T. Rec. G.742 SUB-D, 25 pins

Max attenuation of the input cable Accepted jitter Transfer function Connector type

Output side Bit rate Rated impedance Rated level Output jitter Pulse shape Connector type 2048 kbit/s 50 ppm 75 Ohm or 120 Ohm 2.37 Vp/75 Ohm or 3 Vp/120 Ohm in accordance with G.742/G.823 see mask in Figure 15, ITU-T G.703 D-SUB, 44 pins

- 24 -

Chapter 7 CHARACTERISTICS OF THE INDOOR UNIT

7.2.2 Ethernet Interface (Optional)


Ethernet characteristics Ethernet switch functionalities according to IEEE 802.3 MAC switching MAC learning MAC Ageing IEEE 802.1q VLAN IEEE 802.3x Flow Control IEEE 802.1p QoS IP-V4 ToS

7.3 SERVICE CHANNEL INTERFACE


7.3.1 64-kbit/s Contra-Directional Interface E0 (Optional)
Tolerance Equipment side 100 ppm contra-directional

7.3.2 EDI Interface (Optional)


User output Relay contacts Open contacts Rmin Closed contacts Rmax normally open (NO) or normally closed (NC) 100 Mohm at 500 Vdc 0.5 Ohm

User input Equivalent circuit recognized as a closed contact Equivalent circuit recognized as an open contact 200 Ohm risist. (max) referred to ground 60 kOhm (min) referred to ground

7.3.3 EOW Interface (Optional)


4W Handset Interface Connector 100 Ohm RJ45

7.3.4 Network Management Interface


RJ45 interface LAN type Connector Connection to LAN Ethernet Twisted Pair 802.3 10/100 BaseT RJ45 direct with a CAT5 Twisted Pair

- 25 -

Chapter 7 CHARACTERISTICS OF THE INDOOR UNIT

Protocol

TCP/IP

7.4 MODULATOR / DEMODULATOR


Carrier modulating frequency Tx side Rx side Type of modulation Type of coding Modulating signal Spectrum shaping Equalization Coding gain
-

330 MHz 140 MHz QPSK/16QAM RS plus TCM from 4 Mbit/s to 68 Mbit/s depending on different versions raised cosine (roll-off = 0.25) 24-taps feed forward plus 3-taps decision feedback 6 dB at 10 -3 2.7 dB at 10
-6

7.5 CABLE INTERFACE


Interconnection with the ODU unit Cable length Rated impedance Signal running along the cable Tx nominal frequency Rx nominal frequency Transceiver management signals Carrier for transceiver management signals Remote power supply 330 MHz 140 MHz 388 kbit/s bidirectional IDU to ODU = 17.5 MHz/0 dBm ODU to IDU = 5.5 MHz/0 dBm direct from battery voltage single coaxial cable for both Tx and Rx up to 400 m. with 1/4! cable type for QPSK modulation up to 370 m. with 1/4! cable type for 16QAM modulation 50 Ohm

7.6 AVAILABLE LOOPS


The following loop are available within the IDU: Tributary loop Baseband loop IDU loop

- 26 -

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

8 DESCRIPTION OF THE INDOOR UNIT - PDH


INTERFACES

8.1 1+0/1+1 IDU VERSIONS


The following functional description covers the versions the IDU consists of as shown in chapter Equipment technical specifications!. The IDU is made up of a backplane that equipped with plug in units - a core unit (CU) and a modem unit (MU). In protected terminal configurations two identical Modem Units shall be present in the IDU. CU is a motherboard that have room for an optionally plugged traffic unit (TU) up to 16 E1 channels and an optionally plugged service unit (SU) for EOW and EDI interface which realizing the following functionalities: Line interface Equipment controller IDU loops Radio inter-working function for adaptation of the signals to the modem format Radio protection switching function (RPS) to switch between two receive paths Modem Unit consisting of a power supply, the digital modulator/demodulator and the conversion to and from an analogue intermediate frequency which realizing the following functionalities: Radio interface

8.1.1 Line Interface


The line interface performs the following operations: multiplexing process of the input tributaries generation of the aggregate frame by aggregating multiplexed tributaries and service channel. Bit extraction and demultiplexing process happens at the receive side. Different baseband structures and digital processing of the signal to be forwarded to the QPSK or 16QAM modulator/demodulator is produced by a chip set!. Controls to the chip set and status/alarm reporting from the chip set are given/received by main controller that manages the all equipment. Tx side Refer to Fig. 8.1. The 2 Mbit/s input signal is code converted from HDB3 to NRZ format before being multiplexed. The multiplexing scheme depends on the number and the bit rate of the input tributaries. Attached figures show different multiplexing scheme as follows: Fig. 8.2 - 2x2 Mbit/s multiplexing. The mux performs stuffing operation on each single tributary and generates a proprietary frame embedding the two tributaries to be sent to the Bit Insertion. Opposite operation occurs at the Rx side. Fig. 8.3 - 4x2 Mbit/s multiplexing. The mux aggregates the four 2 Mbit/s tributaries generating a 8448 kbit/s frame as per Recc. G.742. The multiplexed signal is then sent to the Bit Insertion. Opposite operation occurs at the Rx side.

- 27 -

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

Fig. 8.4 - 8x2 Mbit/s multiplexing. The eight 2 Mbit/s tributaries are grouped in two 4x2 Mbit/s groups each of one generating a G742 frame structure at 8448 kbit/s to be sent to the next Bit Insertion. Opposite operation occurs at the Rx side. Fig. 8.5 - 16x2 Mbit/s multiplexing. The sixteen 2 Mbit/s tributaries are grouped in four 4x2 Mbit/s groups each of one generating a G.742 frame structure at 8448 kbit/s. A further multiplexing of the achieved four 8448 kbit/s streams will generate a frame structure at 34368 kbit/s as per Recc. G.751. This latter is to be sent to the Bit Insertion. Opposite operation occurs at the Rx side.

The multiplexed tributaries are then sent to the B.I. for aggregate frame generation occurring at the following bit rate depending on various versions implemented:

Tab. 8.1 Version


2x2 Mbit/s 4x2 Mbit/s 8x2 Mbit/s 16x2 Mbit/s

Aggregate frame
4860 kbit/s 9720 kbit/s 19440 kbit/s 38880 kbit/s

The aggregate frame contains: the main signal from the MUX(s) the framed service signal from the service interface the EOC signals for supervision message propagation towards the remote terminal the frame alignment word the bits dedicated to the FEC.

Rx side Refer to Fig. 8.6. At Rx side the Bit extraction separates the main multiplexed signal from the service signal and then after a proper demultiplexing process (opposite to that previously described at the Tx side) sends them to the output interfaces.

8.1.2 Radio Interface


This functionaly provides the following: QPSK/16QAM modemodulation power supply to IDU and ODU telemetry IDU/ODU cable interface

QPSK/16QAM Modemodulation - Modulation Side See Fig. 8.7. The aggregate signal from the BI undergoes the following process in digital form:

- 28 -

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

serial to parallel conversion differential encoding generation of the shaped modulating signals feeding the IF part of the QAM modulator.

This latter comprises: recovery low pass filter to eliminate signal periodicity 330 MHz local oscillator a 90 phase shifter to supply two mixers with two in quadrature carriers The thus obtained 330 MHz QAM modulated carrier is then sent to the cable interface for connection with ODU.

QAM Modemodulation - Demodulation Side See Fig. 8.7. The 140 MHz, QPSK or 16QAM modulated carrier from the ODU is reaching the IDU through the cable interface. The connection to the demodulator input is made via a cable equalizer for cable loss compensation. The IF section of the QAM demodulator extracts the I and Q analogue signals then digital converted for the following processing: clock recovery baseband equalisation and filtering bit polarity decision differential decoding parallel to serial convertion to recover the aggregate signal. The aggregate signal is then sent to a frame alignement circuit and CRC analysis and then to the error corrector to achieve the BER extimate, the PM and HBER/LBER alarms. Power Supply Refer to Fig. 8.7. The -48 V battery voltage feeds the IDU and ODU circuitry. The service voltages for the IDU feeding are achieved through a DC/DC converter for +3.3 V generation and a step down circuit for -5V. Both voltages are protected against overvoltages and overcurrents. The power to the ODU is given by the same battery running through the interconnection cable. A breaker protects the battery against cable failure. Telemetry IDU/ODU Refer to Fig. 8.1 and Fig. 8.7. The dialogue IDU/ODU is made-up by the main controller and associated peripherals within the ODU. Controls for ODU management and alarm reporting is performed making use of a 388 kbit/s framed signals. The transport along the interconneting cable is performed via two FSK modulated carriers: 17.5 MHz from IDU to ODU; 5.5 MHZ from ODU to IDU. Cable Interface Refer to Fig. 8.7. This circuit permits to communicate to the far ODU through the interconnecting cable. It is mainly made up of a set of filters that: combine the 330 MHz, QAM modulated carrier/the 17.5 MHz carrier/the power supply separate the 140 MHz QAM modulated carrier and the 5.5 MHz carrier

- 29 -

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

8.1.3 Equipment Controller


The controller functionality performs the following: houses the equipment software for equipment management interfaces the embedded CIT-WEB program through supervision ports receive external alarms and route them to relay contacts along with the internal alarms generated by the equipment. The equipment software permits to control and manage all the equipment functionality. It is distributed on two hardware levels: main controller and ODU peripheral controller. The dialogue between main and peripheral controllers is shown in Fig. 8.8. Main Controller The activities executed by the main controller are the following: Communication management: it makes use of SNMP as management protocol and IP as communication protocol stacks. See Fig. 8.9 for details. The interface ports for the equipment management are the following: LAN Ethernet 10/100BaseT used for CIT and NMS connection EOC embedded within the PDH radio frame for connection to the remote NEs Log-in: the main controller manages the equipment or network login/logout by setting and then controlling the user"s ID and relevant password. Database (MIB): validation and storing in a non-volatile memory of the equipment configuration parameters. Equipment configuration: distribution of the parameters stored in the MIB towards the peripheral Ps for their attuation in addition to the controls from user not stored in the MIB (i.e. loops, manual forcing etc...). alarm monitoring: acquisition, filtering and correlation of the alarms gathered from slaved Ps. Local logger and alarm sending to the connected managers: CIT-WEB. Management of the alarm signalling on the front panel. Download: the main controller is equipped with two flash memory banks containing the running program (active bank) and the stand-by program (inactive bank). This permits to download a new software release to the inactive bank without distributing the traffic. Bank switch enables the new release to be used. Download activity is based on FTP protocol which downloads application programs, FPGA configuration, configuration files on main controller inactive bank or directly on the peripheral controllers.

Peripheral Controllers The peripheral controllers take place within the ODU and are slaved to main controller with the task of activating controls and alarm reporting of dedicated functionality.

8.2 IDU LOOPS


To control the IDU correct operation a set of local and remote loops are made available. The commands are forwarded by the CIT-WEB program. Loop block diagram is shown by Fig. 8.10.

8.2.1 Tributary Loop


Tributary Local Loop

- 30 -

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

Each input tributary is routed directly to the trib. output upon receiving the command from the CIT. The Tx line transmission is still on. Tributary Remote Loop Each tributary directed towards the Rx output line is routed back to the Tx line. The Rx line is still on.

8.2.2 Baseband Unit Loop


This kind of loop is only local and is activated at BI/BE level. The Tx line is still on.

8.2.3 IDU Loop


This kind of loop permits to check the full IDU digital operation. When activated, the modulator output is connected to demodulator input.

Aggregate frame

- FSK mod/demod - 388 frame generator/receiver

X0 38.88 MHz

17.5 MHz

5.5 MHz

BI: - main traffic - services - EOC - FEC - FAW

NRZ

MUX 2x2/4x2 8x2/16x2 see Fig. 1.2 CK through Fig. 1.5

Frame generator

NRZ

Code converter

nx2

- 31 -

Code converter

CK

to/from main controller

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

Fig. 8.1

Line Interface Block Diagram - Tx Side

- 32 -

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

Aggregate Ck

Ck 2x2 Mbit/s MUX proprietary frame B.I. Tx data Ck 2x2 Mbit/s DEMUX proprietary frame B.E. Rx data

Fig. 8.2

2x2 Mbit/s Multiplexing/Demultiplexing

Aggregate Ck 4x2 Mbit/s Ck MUX 2 ->8 G.742 B.I. Framed data 8448 Tx Ck DEMUX 2 ->8 G.742 B.E. Framed data 8448 Rx

4x2 Mbit/s

Fig. 8.3

4x2 Mbit/s Multiplexing/Demultiplexing

- 33 -

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

Aggregate Ck 4x2 Mbit/s Ck MUX 2 ->8 G.742 Data B.I.

4x2 Mbit/s MUX 2 ->8 G.742 Framed data 8448 Tx Data

4x2 Mbit/s DEMUX 8 -> 2 G.742

Ck 8448 kHz Tx Data B.E.

4x2 Mbit/s DEMUX 8 -> 2 G.742 Framed data 8448 Rx

Fig. 8.4

8x2 Mbit/s multiplexing/demultiplexing

- 34 -

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

Aggregate Ck 4x2 Mbit/s MUX 2 ->8 G.742 4x2 Mbit/s MUX 2 ->8 G.742 4x2 Mbit/s MUX 2 ->8 G.742 Ck 8448 kHz Tx 4x2 Mbit/s MUX 2 ->8 G.742 Framed data 8448 kbit/s Tx Aggregate Ck 4x2 Mbit/s DEMUX 8 ->2 G.742 4x2 Mbit/s DEMUX 8 ->2 G.742 4x2 Mbit/s DEMUX 8 ->2 G.742 Ck 8448 kHz 4x2 Mbit/s DEMUX 8 ->2 G.742 Framed data 8448 kbit/s Tx MUX 34->8 G.751 Ck 34368 kHz Framed data 34368 kbit/s B.E. MUX 8->34 G.751 Ck 34368 kHz Tx Framed data 34368 kbit/s B.I.

Fig. 8.5

16x2 Mbit/s Multiplexing/Demultiplexing

- 35 -

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

Fig. 8.6
DEMUX 2/2x2/4x2 8x2/16x2 BE from demodulator side of the radio interface See Fig. 8.2 through Fig. 8.5 Code Converter Code Converter nx2 Mbit/s

Line Interface Block Diagram (Rx Side)

- 36 -

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

Fig. 8.7 Radio Interface Block Diagram

- 37 -

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

Fig. 8.8 Main and Peripheral Controller Connection

Applic./present session layer

Application Software SNMP TCP/UDP IP PPP EOC LLC MAC Ethernet LAN

Transport layer Routing layer Data link layer Physical layer


Fig. 8.9 IP Protocol Stack

- 38 -

Chapter 8 DESCRIPTION OF THE INDOOR UNIT - PDH INTERFACES

Fig. 8.10 IDU Loopback

- 39 -

Chapter 9 CHARACTERISTICS OF THE OUTDOOR UNIT

9 CHARACTERISTICS OF THE OUTDOOR UNIT


9.1 GENERAL
The following ODU characteristics are guaranteed for the temperature range from -33 C to +55 C.

9.2 TECHNICAL SPECIFICATIONS


Output power at the antenna side Transceiver tuning range
-

see Tab. 9.9 112 MHz (420 MHz duplex spacing) 120 MHz (728 MHz duplex spacing) 330 MHz 336 MHz 448 MHz 560 MHz see Tab. 9.1 see Tab. 9.2 see Tab. 9.3 see Tab. 9.4 see Tab. 9.5 see Tab. 9.6 see Tab. 9.7 see Tab. 9.8 125 kHz step 196/168/161 MHz 311,32 MHz 530 MHz 266 MHz 420/728 MHz 1010 MHz 1008 MHz 1260 MHz 20 dB, 1 dB step 40 dB dynamic, 1 dB software adjustable 40 dB

15 GHz

18 GHz 23 GHz 25/28 GHz 38 GHz Covering Subbands


-

13 GHz 15 GHz 18 GHz 23 GHz 25 GHz 28 GHz 38 GHz 7 GHz

RF frequency agility Duplex spacing 7 GHz 8 GHz 11 GHz 13 GHz 15 GHz 18 GHz 23/25/28 GHz 38 GHz ATPC Transmit power attenuation range Transmitter shut-down
-

- 40 -

Chapter 9 CHARACTERISTICS OF THE OUTDOOR UNIT

Antenna side flange 7/8 GHz 13 GHz 15 GHz 18/23/25 GHz 28/38 GHz AGC dynamic range Accuracy of Rx level indication (PC reading) Maximum input level for BER 10 Type of connector at the cable interface side Signals at the cable interface
-

PBR84 or UBR84 UDR120 or UBR140 UDR140 or UBR140 PBR220 or UBR220 PBR320 or UBR320 from -20 dBm to threshold corresponding to BER10 3 dB in the range -40 dBm to -75 dBm 4 dB in the range -30 dBm to -40 dBm -20 dBm N!
-3

-3

QAM modulated carrier Telemetry Telemetry carriers

330 MHz (from IDU to ODU) 140 MHz (from ODU to IDU) 388 kbit/s 17.5 MHz (from IDU to ODU) 5.5 MHz (from ODU to IDU) RF loop (not available for frequencies 18 GHz)

Available Loops

PBR with integrated antenna UBR with separated antenna

- 41 -

Chapter 9 CHARACTERISTICS OF THE OUTDOOR UNIT

Tab. 9.1 13 GHz covering subbands Subband 1L


12751 - 12835

Subband 2L
12835 - 12919

Subband 3L
12891 - 12975

Subband 1H
13017 - 13101

Subband 2H
13101 - 13185

Subband 3H
13157 - 13241

Tab. 9.2 15 GHz covering subbands Subband 1L


14501 - 14620

Subband 1 H
15229 - 15348

Tab. 9.3 18 GHz covering subbands Subband 1L


17714 - 18044

Subband 2L
18016 - 18346

Subband 3L
18346 - 18676

Subband 1H
18724 - 19054

Subband 2H
19026 - 19356

Subband 3H
19356 - 19686

Tab. 9.4 23 GHz covering subbands Subband 1L


22002.75 - 22338.75

Subband 2L
22254.75 - 22590.75

Subband 1H
23010.75 - 23346.75

Subband 2H
23262.75 - 23598.75

- 42 -

Chapter 9 CHARACTERISTICS OF THE OUTDOOR UNIT

Tab. 9.5 25 GHz covering subbands Subband 1L


24549 - 24997

Subband 2L
24997 - 25445

Subband 1H
25557 - 26005

Subband 2H
26005 - 26453

Tab. 9.6 28 GHz covering subbands Subband 1L


27548.5 - 27996.5

Subband 2L
27996.5 - 28444.5

Subband 1H
28556.5 - 29004.5

Subband 2H
29004.5 - 29452.5

Tab. 9.7 38 GHz covering subbands Subband 1L


37058 - 37618

Subband 2L
37618 - 38178

Subband 1H
38318 - 38878

Subband 2H
38878 - 39438

Tab. 9.8 7 GHz Covering Subbands (ITU-R F.385-7) T/R Spacing 161 MHz Subband 1 2 3 161 MHz 1 2 3 168 MHz 1 2 3 196 MHz 1 2 3 Lower Half (L, MHz) 7142.5-7180.5 7180.5-7236.5 7208.5-7264.5 7424.5-7480.5 7480.5-7536.5 7508.5-7564.5 7443-7499 7499-7555 7527-7583 7107-7163 7163-7219 7191-7247 Upper Half (H, MHz) 7285.5-7341.5 7341.5-7397.5 7369.5-7425.5 7585.5-7641.5 7641.5-7697.5 7669.5-7725.5 7611-7667 7667-7723 7695-7751 7303-7359 7359-7415 7387-7443

- 43 -

Chapter 9 CHARACTERISTICS OF THE OUTDOOR UNIT

Tab. 9.9 Nominal output power 1 dB tolerance ZXMW PR10


7 GHz 8 GHz 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 25 GHz 28 GHz 38 GHz

Output power 4QAM


+27 dBm +27 dBm +25 dBm +25 dBm +25 dBm +20 dBm +20 dBm +20 dBm +19 dBm +17 dBm

Output power 16QAM


+22 dBm +22 dBm +20 dBm +20 dBm +20 dBm +15 dBm +15 dBm +15 dBm +14 dBm +13 dBm

Note: In 1+1 hot stand-by version the output power decreases by the following values: -4 dB 0.5 dB (balanced hybrid) -1.7/7 dB 0.3 dB (unbalanced hybrid)

- 44 -

Chapter 10 DESCRIPTION OF THE OUTDOOR UNIT

10 DESCRIPTION OF THE OUTDOOR UNIT


10.1 GENERAL
The 1+0 ODU (refer to Fig. 10.1) consists of a two-shell aluminum mechanical structure, one shell housing all the ODU circuits, the other forming the covering plate. On the ODU are accessible: the N! type connector for cable interfacing IDU and ODU the BNC! connector for connection to a multimeter with the purpose to measure the received field strength a ground bolt.

The 1+1 hot stand#by version (refer to Fig. 10.2) consist of two 1+0 ODUs mechanically secured to a structure housing the hybrid for the antenna connection.

10.2 TRANSMIT SECTION


Refer to block diagram shown in Fig. 10.3. The 330 MHz QAM modulated carrier from the cable interface (see chapter 10.4) is forwarded to a mixer passing through a cable equalizer for cable loss compensation up to 40 dB at 330 MHz. The mixer and the following bandpass filter give rise to a second IF Tx carrier the frequency of which depends on the go/return frequency value. The mixer is of SHP type. The IF Tx frequency is P controlled. Same happens to Rx IF and RF local oscillators. This latter is common to both Tx and Rx sides. The IF carrier is converted to RF and then amplified making use of a MMIC circuit. The conversion mixer is SSB type with side band selection. The power at the MMIC output can be manually attenuated by 20 dB, 1 dB step. Total attenuation is 40 dB including the 20 dB attenuator that follows. The automatic adjustment is performed making use of an ATPC (see paragraph 10.5 for details). The regulated output power is kept constant against amplifier stage gain variation by a feedback including the AGC. Before reaching the antenna side the RF signal at the output of MMIC passes through the following circuits: a de-coupler plus detector diode to measure the output power a circulator to protect the amplifier stages against possible circuit mismatch. a ON/OFF switch for 1+1 operation a 0 or 20 dB attenuator to made up a total attenuation of 40 dB an RF band-pass filter for antenna coupling.

An RF coupler plus a detector and a shift oscillator made up the RF loop which is enabled upon receiving a P control. The RF loop permits the Tx power to return back to receive side thus controlling the total local radio terminal performance.

- 45 -

Chapter 10 DESCRIPTION OF THE OUTDOOR UNIT

10.3 RECEIVE SECTION


The RF signal from the Rx bandpass filter is sent to a low noise amplifier that improves the receiver sensitivity. The following down#converter translates the RF frequency to approximately 765 MHz. The conversion mixer is SSB type. The sideband selection is given through a !P control. A second down converter generates the 140 MHz IF carrier to be sent to the demodulator within the IDU. The level of the IF carrier is kept constant to #5 dBm thank to the IF amplifier stages, AGC controlled, distributed in the IF chain. In addition the AGC gives a measure of the receive RF level. Between two amplifiers a bandpass filter assures the required selectivity to the receiver. The filter is SAW type and the bandwidth depends on the transmitted capacity as follows: 4 MHz (2x2 Mbit/s # QPSK; 4x2 Mbit/s # 16QAM) 12 MHz (8x2/16x2 Mbit/s # 16QAM) 28 MHz (16x2 Mbit/s # QPSK)

10.4 CABLE INTERFACE


The cable interface permits to interface the cable interconnecting IDU to ODU and vice versa. It receives/transmits the following signals: 330 MHz (from IDU to ODU) 140 MHz (from ODU to IDU) 17.5 MHz (from IDU to ODU) 5.5 MHz (from ODU to IDU) remote power supply.

The 17.5 MHz and 5.5 MHz FSK modulated carriers, carry the telemetry channel. This latter consists of two 388 kbit/s streams one from IDU to ODU with the information to manage the ODU (RF power, RF frequency, capacity, etc...) while the other, from ODU to IDU, sends back to IDU measurements and alarms of the ODU. The ODU management is made by a !P.

10.5 ATPC OPERATION


The ATPC regulates the RF output power of the local transmitter depending on the value of the RF level at the remote terminal. This value has to be preset from the local terminal as threshold high and low. The difference between the two thresholds must be equal or higher than 3 dB. As soon as the received level crosses the preset threshold level low (see Fig. 10.6) due to the increase of the hop attenuation, a microP at the received side of the remote terminal sends back to the local terminal a control to increase the transmitted power. The maximum ATPC range is 20 dB. If the hop attenuation decreases and the threshold high is crossed then the control sent by the microP causes the output power to decrease. The 20 dB ATPC range can be reduced from the maximum value to 0 dB, by 1 dB step, consequently to a reduction of the output maximum power through an adjusted attenuation. Total adjustment attenuation is 40 dB formed by a variable attenuation part from 0 to 20 dB, 1 dB step and a fixed attenuation part of 0 dB or 20 dB.

- 46 -

Chapter 10 DESCRIPTION OF THE OUTDOOR UNIT

ATPC behaves according the following example: maximum output power is +20 dBm: ATPC range is 20 dB output power reduced from +20 dBm to 0 dBm, 1 dB step using the variable attenuation: ATPC range is reduced from 20 dB to 0 dB consequently reduction of output power from #1 dBm to #20 dBm, 1 dB step, using both fixed and variable attenuation: ATPC range is reduced from 19 dB to 0 dB consequently.

10.6 1+1 Tx SYSTEM


The two ODUs are coupled to the antenna side via a balanced or unbalanced hybrid. 1+1 Tx switching occurs in the 1+1 hot stand#by 1 antenna or 2 antennas versions as shown in Fig. 10.4 and Fig. 10.5. The transmitter switchover is electromechanical type and consists of two ON/OFF switches within the two ODUs that assure at least 40 dB insulation on the stand#by transmitter. Transmit alarm priority is shown in Tab. 10.1. Priority Levels Priority 1 Priority 2 Priority 3 Priority 3 Highest Priority 3 Priority 3 Priority 3 Priority 3 Priority 3 Priority 3 RIM PSU Alarm Manual forcing Cable Short Alarm Cable Open Alarm Modulator Failure ODU Unit Failure Alarm VCO Failure Alarm IF Unit Alarm ODU PSU Alarm Tx Power Low Alarm Request from remote terminal (both receivers alarmed) Revertive Tx (branch one preferential) Definition

Priority 4

Lowest

Priority 5

- 47 -

Chapter 10 DESCRIPTION OF THE OUTDOOR UNIT

10.7 POWER SUPPLY


The battery voltage is dropped from the cable interface and then sent to a DC/DC converter to generate three stabilized output voltages to be distributed to the ODU circuitry: +3.5 V a voltage comprised between +6.2 V and +8.2 V to power MMIC amplifiers operating at different frequency bands a #12 V through an inverter circuit.

Each voltage is protected against overcurrent with automatic restart. Protection against overvoltage occurs as soon as the output voltage raises more than 15% respect to the nominal voltage. The restart is automatic.

Fig. 10.1 1+0 ODU version

- 48 -

Chapter 10 DESCRIPTION OF THE OUTDOOR UNIT

Fig. 10.2 1+1 hot stand#by version

- 49 -

Chapter 10 DESCRIPTION OF THE OUTDOOR UNIT

- 50 -

Chapter 10 DESCRIPTION OF THE OUTDOOR UNIT

Fig. 10.4 1+1 hot stand#by 1 antenna

Fig. 10.5 1+1 hot stand#by 2 antennas

- 51 -

Chapter 10 DESCRIPTION OF THE OUTDOOR UNIT

Fig. 10.6 ATPC operation

- 52 -

Chapter 11 INSTALLATION AND PROCEDURES FOR ENSURING ELECTROMAGNETIC COMPATIBILITY

11 INSTALLATION AND PROCEDURES FOR


ENSURING ELECTROMAGNETIC COMPATIBILITY

11.1 GENERAL
The equipment consists of IDU and ODU(s) units and is mechanically made up of a wired 19 ! subrack (IDU) and a weather proof metallic container (ODU). The two units are shipped together in an appropriate cardboard box. After unpacking, mechanical installation takes place followed by electrical connections as described in the following paragraphs.

11.2 MECHANICAL INSTALLATION


11.2.1 IDU Installation
The front side of the IDU mechanical structure is provided with holes at the sides. This allows to fasten the subrack to a 19! rack by means of four M6 screws. If two or more IDUs are to be mounted, leave at least 1/2 rack unit space (22 mm) between two IDUs to avoid overheating problems.

11.3 ELECTRICAL WIRING


The electrical wiring must be done using appropriate cables thus assuring the equipment complies with electromagnetic compatibility standards. The cable terminates to flying connectors which have to be connected to the corresponding connectors on the equipment front. Position and pin-out of the equipment connectors are available in this section. Tab. 11.1 shows the characteristics of the cables to be used and Tab. 11.1 Interconnecting points
Battery Tributary signals

the flying connector types.

Type of connector terminating the cable


Polarised SUB-D 3W3 female connector 40 pin SUB-D male connector 15 pin SUB-D female connector with shielded holder Faston male type

Type of cable/conductor
Section of each wire 2.5 sq.mm -120/75 Ohm balanced/ unbalanced 16 pairs with shield 15 conductor cable with double brass sheath type interconductor DB15 or equivalent Section area 6 sq. mm.

User input/alarm output GND

- 53 -

Chapter 11 INSTALLATION AND PROCEDURES FOR ENSURING ELECTROMAGNETIC COMPATIBILITY

11.4 GROUNDING CONNECTION


Fig. 11.1 and annexed legend show how to perform the grounding connections.

Fig. 11.1 Grounding Legend (1) IDU grounding point, fast-on type. The cross section area of the cable used must be 4 sq. mm. The fast-on is available on both sides of the IDU. (2) ODU grounding bolt. The cross section area of the cable used must be 16 sq. mm (3) IDU-ODU interconnection cable type Celflex CUH 1/4 ! terminated with N-type male connectors at both sides. (4) Grounding kit type Cabel Metal or similar to connect the shield of interconnection cable. (5) Matching cable (tail) terminated with N male and N female connectors. (6) Battery grounding point of IDU to be connected to earth by means of a cable with a section area 2.5 sq. mm. Length 10 m. (7)Grounding cords connected to a real earth inside the station. The cross section area of the cable must be 16 sq. mm

- 54 -

Chapter 12 USER CONNECTIONS

12 USER CONNECTIONS
12.1 CONNECTOR USE FOR 1+0/1+1 STANDARD VERSION
User connections are performed through connectors on the IDU front panel modules. The connectors are the following: Trib IN/OUT: 75 or 120 25-pin SUB-D male connector. For SUB-D connector details Tab. 12.1. NMS LA: RJ45 connector. Connector details refer to Tab. 12.2. NMS LAN: RJ45 connector. Connector details refer to Tab. 12.2. 50 Ohm connector for interconnection to ODU 3 pin SUB-D connector for interconnection to battery. EDI: 15-pin SUB-D male connector refer to Tab. 12.3 RJ45 EOW connector.

- 55 -

Chapter 12 USER CONNECTIONS

12.2 STANDARD VERSION CONNECTORS

Tab. 12.1 Tributary connector pin-out


Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 Signal name R1+ R1R2+ R2R3+ R3R4+ R4R5+ R5T1+ T1T2+ T2T3+ T3T4+ T4T5+ T5R6+ R6T6+ T6R7+ R7T7+ T7120 Ohm impedance Tributary input (hot wire) Tributary input (cold wire) Tributary input (hot wire) Tributary input (cold wire) Tributary input (hot wire) Tributary input (cold wire) Tributary input (hot wire) Tributary input (cold wire) Tributary input (hot wire) Tributary input (cold wire) Tributary output (hot wire) Tributary output (cold wire) Tributary output (hot wire) Tributary output (cold wire) Tributary output (hot wire) Tributary output (cold wire) Tributary output (hot wire) Tributary output (cold wire) Tributary output (hot wire) Tributary output (cold wire) Tributary output (hot wire) Tributary output (cold wire) Tributary output (hot wire) Tributary output (cold wire) Tributary output (hot wire) Tributary output (cold wire) Tributary output (hot wire) Tributary output (cold wire) 75 Ohm impedance Tributary input Ground Tributary input Ground Tributary input Ground Tributary input Ground Tributary input Ground Tributary output Ground Tributary output Ground Tributary output Ground Tributary output Ground Tributary output Ground Tributary output Ground Tributary output Ground Tributary output Ground Tributary output Ground

- 56 -

Chapter 12 USER CONNECTIONS

40 41 42 43 44

R8+ R8T8+ T8-

Tributary output (hot wire) Tributary output (cold wire) Tributary output (hot wire) Tributary output (cold wire)

Tributary output Ground Tributary output Ground

Note: The 75 Ohm impedance tributary connector pin-out is referred to the flying connectors to be connected to the equipment connectors.

Tab. 12.2 100BaseT connector pin-out for 10/100BaseT Ethernet connection Pin
1 2 3 4 5 6 7 8

Description
Tx+ TxRx+ --Rx---

Tab. 12.3 100BaseT connector pin-out for 10/100BaseT Ethernet connection


Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Name EDI_OUT1a EDI_OUT1b EDI_IN1+ Function EDI Output 1 EDI input 1

EDI_IN2+ EDI_OUT2a EDI_OUT2b EDI_OUT1com GND EDI_IN1GND EDI_IN2GND EDI_OUT2com

EDI input 2 EDI Output 2 EDI output 1 common Ground EDI input 1 Ground EDI input2 Ground EDI output 2 common

- 57 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

13 INSTALLATION ONTO THE POLE OF THE ODU


WITH SEPARATED ANTENNA

13.1 INSTALLATION KIT


Following installation kits are supplied with the equipment depending on different versions:

1+0 version antisliding strip (see Fig. 13.1) supporting plate plus 60-114 mm pole fixing bracket and relevant nuts and bolts (see Fig. 13.2) adapting tools and relevant bolts and nuts for 219 mm pole (see Fig. 13.3) antenna side flange, variable as function of RF frequency (see Fig. 13.4) support with ODU fast locking mechanism (see Fig. 13.2) flexible waveguide trunk for connection to antenna (optional) (see Fig. 13.2) kit for ground connection making part of ODU

1+1 version antisliding strip (see Fig. 13.1) supporting plate plus pole fixing bracket and relevant nuts and bolts (see Fig. 13.2) adapting tools and relevant bolts and nuts for 219 mm pole (see Fig. 13.3) hybrid with ODU fast locking mechanism (see Fig. 13.5) flexible waveguide trunk for connection to antenna (optional (see Fig. 13.2) kit for ground connection making part of the two ODUs.

- 58 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

13.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)


N.2 13mm torque wrench N.1 15 mm torque wrench N.1 17 mm torque wrench N.1 3 mm allen wrench

13.3 INSTALLATION PROCEDURE


Installation procedure proceeds according to the following steps: 2 Version 1+0: installation onto the pole of the supporting plate 1 Version 1+1: installation onto the pole of the supporting plate Installation of the ODU (common to both 1+0 and 1+1 version) ODU grounding

1+0 version - Installation onto the pole of the supporting plate Fig. 13.1 - Mount antislide strip around the pole. The position of the plastic blocks depends on the position of the supporting plate (see next step) Fig. 13.2 - Adhere the supporting plate to the antisliding strip plastic blocks and then secure it to the pole through the fixing bracket for 60-114 mm pole (see Fig. 13.2). Bolts and nuts are available on the supporting plate. Tightening torque must be 32 Nm. Warning: As shown in Fig. 13.3 an adapting kit must be used for the 219 mm pole. It consists of an additional plate to enlarge the standard supporting plate dimension and relevant U-bolt for 219 mm pole fixing. Fig. 13.4 - Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimensions of which depend on the waveguide type. Tighten progressively and alternatively the four screws with the following torque:

Tab. 13.1 Frequencies


from 18 to 38 GHz up to 15 GHz

Screw
allen screw M3 allen screw M4

Tool
allen key 2.5 mm allen key 3 mm

Torque
1 Nm 2 Nm

In case of 219 mm pole, an adapting kit is supplied for the purpose.

- 59 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

Fig. 13.4 - Fix the antenna side flange to the support with ODU fast locking mechanism. The flange can be mounted horizontally (as shown in Fig. 13.4) or vertically as function of convenience. Fig. 13.5 - Fix the support with ODU fast locking mechanism to the supporting plate making use of available bolts and nuts. Fig. 13.5 shows three possible positions. Tightening torque must be 18 Nm. 1+1 version - Installation onto the pole of the supporting plate Fig. 13.1 - Mount antislide strip around the pole. The position of the plastic blocks depends on the position of the supporting plate (see next step) Fig. 13.2 - Position the supporting plate to the antisliding strip plastic blocks and then secure it to the pole through the fixing bracket for 60-114 mm pole (see Fig. 13.2). Bolts and nuts are available on the supporting plate kit. Tightening torque must be 32 Nm. Fig. 13.6 - Secure the hybrid with ODU fast locking mechanism to the supporting plate using bolt and nuts available on the support plate. Tightening torque must be 18 Nm. Remove the plastic cover from the hybrid flange sides. Warning: Do not remove the foil from the hybrid flange sides. Fig. 13.6 - Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimensions of which depend on the waveguide type. Tighten progressively and alternatively the four screws with the following torque:

Tab. 13.2 Frequencies


from 18 to 38 GHz up to 15 GHz

Screw
allen screw M3 allen screw M4

Tool
allen key 2.5 mm allen key 3 mm

Torque
1 Nm 2 Nm

Warning: It is advisable to shape the waveguide flexible trunk, connecting ODU flange with antenna flange as shown in Fig. 13.9. This avoids possible condensate to be channelled towards the ODU flange.

Installation of the ODU 1. Remove the plastic cover from the ODU flange side. Apply silicon grease e.g. type RHODOSIL PATE 4 to the O-ring of Fig. 13.8. Warning: Do not remove the foil from the flange. Bring the ODU with the two hands and position the ODU handle at the bottom side. Position the ODU body close to the support with ODU fast locking mechanism and align ODU side flange (see Fig. 13.8) to antenna side flange ( see Fig. 13.4 - 1+0 version) or hybrid side flange (see Fig. 13.6 - 1+1 version). With respect to the flange alignment, turn the ODU body approx. 30 anti-clockwise and then insert the ODU body into the support and search for alignment between reference tooth on the support (see Fig. 13.4 - 1+0 version or Fig. 13.6 - 1+1 version) and ODU body reference tooth (see detail Fig. 13.8) When alignment is achieved, turn the ODU body clockwise until clack ! is heard and the ODU rotation stops. Secure ODU body on the support by tightening bolts (1) (see Fig. 13.4 - 1+0 version or Fig. 13.6 - 1+1 version). Tightening torque must be 6 Nm.

2. 3.

Note: For 1+0 version the ODU can assume positions of Fig. 13.7 depending on the polarisation. 4.

5. 6.

- 60 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

Final assembly of 1+1 version is shown in Fig. 13.9.

13.4 GROUNDING
The ODU must be connected to ground making reference to details of Fig. 13.10.

Fig. 13.1

Antisliding strip

Plastic blocks

- 61 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

Adapting kit for 219 mm pole

Fig. 13.2 60#114 mm pole supporting plate fixing

- 62 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

Fig. 13.3 Adapting kit for 219 mm pole

Use 17 mm wrench (32Nm torque)

Supporting plate

Use 15 mm wrench (32Nm torque)

60-114 mm pole supporting plate fixing

- 63 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

Flexible waveguide trunk

Antenna side flange

Support with ODU fast locking mechanism

Reference tooth Reference tooth

1 1 13 mm wrench 6 Nm torque

Position of antenna side flange

Mounting position Fig. 13.4 possible Mounting possible position

- 64 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

Fig. 13.5

- 65 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

Fig. 13.6

- 66 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

Fig. 13.7 Position of the ODU body depending on the polarisation for 1+0. For 1+1 the polarisation is always vertical: handle at the left side.

- 67 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

Fig. 13.8 ODU Body Reference Tooth

- 68 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

Fig. 13.9 Final ODU Assembly of 1+1 Version

- 69 -

Chapter 13 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA

Fig. 13.10 ODU Grounding

- 70 -

Chapter 14 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA

14 INSTALLATION ONTO THE WALL OF THE ODU


WITH SEPARATED ANTENNA

14.1 INSTALLATION KIT


Following installation kits are supplied with the equipment depending on different versions:

1+0 version wall supporting plate with additional contact surface extension plates (see Fig. 14.1) antenna side flange, variable as function of RF frequency (see Fig. 14.2) support with ODU fast locking mechanism (see Fig. 14.2) flexible waveguide trunk for connection to antenna (optional) (see Fig. 14.2) kit for ground connection making part of ODU

1+1 version supporting plate with additional contact surface extension tools (see Fig. 14.1) hybrid with ODU fast locking mechanism (see Fig. 14.4) flexible waveguide trunk for connection to antenna (optional (see Fig. 14.2) kit for ground connection making part of the two ODUs.

14.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)


N.2 13mm torque wrench N.1 15 mm torque wrench N.1 17 mm torque wrench N.1 3 mm allen wrench

14.3 INSTALLATION PROCEDURE


Installation procedure proceeds according to the following steps: Version 1+0: installation onto the wall of the supporting plate Version 1+1: installation onto the wall of the supporting plate Installation of the ODU (common to both 1+0 and 1+1 version) ODU grounding

- 71 -

Chapter 14 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA

1+0 version - Installation onto the wall of the supporting plate Fig. 14.1 - Fix on the supporting plate the two supplied extension plates to increase the wall contact surface. Fig. 14.1 - Secure the supporting plate on the wall using the more suitable screws. Fig. 14.2 - Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimensions of which depend on the waveguide type. Tighten progressively and alternatively the four screws with the following torque:

Tab. 14.1 Frequencies


from 18 to 38 GHz up to 15 GHz

Screw
allen screw M3 allen screw M4

Tool
allen key 2.5 mm allen key 3 mm

Torque
1 Nm 2 Nm

Fig. 14.2 - Fix the antenna side flange to the support with ODU fast locking mechanism. The flange can be mounted horizontally (as shown in Fig. 14.2) or vertically as function of convenience. Fig. 14.3 - Fix the support with ODU fast locking mechanism to the supporting plate making use of available bolts and nuts. Fig. 14.3 shows three possible positions. Tightening torque must be 18 Nm.

1+1 version - Installation onto the wall of the supporting plate Fig. 14.1 - Fix on the supporting plate the two supplied extension plates to increase the wall contact surface. Fig. 14.1 - Secure the supporting plate on the wall using the more suitable screws. Fig. 14.4 - Secure the hybrid with ODU fast locking mechanism to the supporting plate using bolt and nuts available on the support plate. Tightening torque must be 18 Nm. Remove the plastic cover from the hybrid flange sides. Warning: Do not remove the foil from the hybrid flange sides. Fig. 14.4 - Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimensions of which depend on the waveguide type. Tighten progressively and alternatively the four screws with the following torque:

Tab. 14.2 Frequencies


from 18 to 38 GHz up to 15 GHz

Screw
allen screw M3 allen screw M4

Tool
allen key 2.5 mm allen key 3 mm

Torque
1 Nm 2 Nm

Warning: It is advisable to shape the waveguide flexible trunk, connecting ODU flange with antenna flange as shown in Fig. 14.7 This avoids possible condensate to be channelled towards the ODU flange.

Installation of the ODU

- 72 -

Chapter 14 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA

1.

Remove the plastic cover from the ODU flange side. Apply silicon grease e.g. type RHODOSIL PATE 4 to the O-ring of Fig. 14.6. Warning: Do not remove the foil from the flange. Bring the ODU with the two hands and position the ODU handle at the bottom side. Position the ODU body close to the support with ODU fast locking mechanism and align ODU side flange (see Fig. 14.6) to antenna side flange ( see Fig. 14.2 - 1+0 version) or hybrid side flange (see Fig. 14.4 - 1+1 version). With respect to the flange alignment, turn the ODU body approx. 30 anti-clockwise and then insert the ODU body into the support and search for alignment between reference tooth on the support (see Fig. 14.2 - 1+0 version or Fig. 14.4 - 1+1 version) and ODU body reference tooth (see detail Fig. 14.6) When alignment is achieved, turn the ODU body clockwise until clack! is heard and the ODU rotation stops. Secure ODU body on the support by tightening bolts (1) (see Fig. 14.2 - 1+0 version or Fig. 14.4 - 1+1 version). Tightening torque must be 6 Nm.

2. 3.

Note: For 1+0 version the ODU can assume positions of Fig. 14.5 depending on the polarisation. 4.

5. 6.

Final assembly of 1+1 version is shown in Fig. 14.7.

- 73 -

Chapter 14 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA

14.4 GROUNDING
The ODU must be connected to ground making reference to details of Fig. 14.8.

Extension plate

Supporting plate

M8 bolt and nut

Wall supporting plate

Fig. 14.1 Wall supporting plate

- 74 -

Chapter 14 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA

Flexible waveguide trunk

Antenna side flange

Support with ODU fast locking mechanism

Reference tooth Reference tooth

1 1 13 mm wrench 6 Nm torque

Position of antenna side flange

Support with ODU fast locking mechanism

Fig. 14.2 Support with ODU fast locking mechanism

- 75 -

Chapter 14 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA

Mounting possible positions

Fig. 14.3 Mounting possible positions

- 76 -

Chapter 14 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA

Use (18 13 Nm mm torque) wrench

Hybrid with ODU fast locking mechanism

Reference tooth

Reference tooth

RT1

RT2

Fig. 14.4

- 77 -

Chapter 14 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA

Fig. 14.5 Position of the ODU body depending on the polarisation for 1+0. For 1+1 the polarisation is always vertical: handle at the left side.

- 78 -

Chapter 14 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA

Fig. 14.6 ODU body reference tooth

- 79 -

Chapter 14 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA

Fig. 14.7 Final ODU assembly of 1+1 version

- 80 -

Chapter 14 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA

1. Bolt 2. Spring washer 3. Flat washer 4. Earth cable collar 5. Flat washer Fig. 14.8 ODU grounding

- 81 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

15 INSTALLATION ONTO THE POLE OF THE ODU


WITH INTEGRATED ANTENNA

15.1 FOREWORD
The installation onto the pole of the ODU with integrated antenna concerns both 1+0 and 1+1 versions.

15.2 INSTALLATION KIT


Following installation kits are supplied with the equipment depending on different versions: 1+0 version 60 to 114 mm pole mounting kit consisting of: 1+1 version pole mounting kit from 60 to 114 mm for 1+1 consisting of: centering ring and relevant screws (see Fig. 15.1) antislide strip (see Fig. 15.2) centering ring and relevant screws (see Fig. 15.1) antislide strip (see Fig. 15.2) pole support system and pole fixing brackets (see Fig. 15.3) ODU with O-ring and devices for ground connection

pole support system and pole fixing brackets (see Fig. 15.3) hybrid mechanical body (see Fig. 15.12) polarization twist disk (see Fig. 15.13) 2 ODUs with O-rings and devices for ground connection

15.3 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)


N.2 13 mm torque wrench N.1 15 mm torque wrench N.1 17 mm torque wrench N.1 3 mm allen wrench

- 82 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

15.4 INSTALLATION PROCEDURE


Installation procedure proceeds according with the following steps: 1+0 version 1. 2. 3. 4. 5. installation onto the pole of the support system installation of the antenna installation of ODU antenna aiming ODU grounding

1+1 version 1. 2. 3. 4. 5. 6. installation onto the pole of the support system installation of the antenna installation of hybrid circuit installation of the two ODUs antenna aiming ODU grounding

15.4.1 Installation onto the pole of the support system and the antenna
Fig. 15.1 - Set the antenna in such a position as to be able to operate on its rear side. Locate the five threaded holes around antenna flange. Mount centering ring onto antenna flange and tight it with 3 calibrated bolts. Caution: centering ring should be mounted so that the screws do not stick out. Define if the antenna will be mounted with vertical or horizontal polarization. Check that free drain holes stay at bottom side. Mount bolt type M10x30, in position A leaving it loose of 2 cm approx. With horizontal polarization mount bolt type M10x30 in position D, leaving it loose of 2 cm approx. Fig. 15.2 - Mount antislide strip onto the pole. Place blocks as in Fig. 15.2 following antenna aiming direction. Tighten the strip with screwdriver. Fig. 15.3 - Mount pole supporting system with relevant pole fixing brackets following antenna aiming direction as indicated by arrow. Antislide strip should result at the center of supporting plate. Supporting system should lean against antislide clamp with the tooth as in Fig. 15.4. Position the antenna in such a way that bolt in position A or D of Fig. 15.1 cross through hole E of Fig. 15.5. Secure the support system to the pole by means of the pole fixing brackets and relevant fixing bolts. Fig. 15.6 - Rotate the antenna body until the remainder three antenna holes coincide with the three support holes. Secure the antenna to the support by thightening the relevant passing through bolts.

- 83 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

15.4.2 Installation of ODU


1+0 version 1. 2. 3. Apply silicon grease e.g. RHODOSIL PATE 4! to the O-ring (4) of Fig. 15.9 by protecting finger hands with gloves. Bring the ODU with the two hands and position the ODU handle at the bottom side. The ODU handle can assume position of Fig. 15.7 depending on the polarization. Position the ODU body near the support system and align ODU side flange to antenna side flange (see Fig. 15.8). With respect to the flange alignment, turn the ODU body approx. 30 anti-clockwise and then insert the ODU body into the support and search for alignemnt between reference tooth on the support (see Fig. 15.8) and ODU body reference tooth (see detail of Fig. 15.9). When alignment is achieved, turn the ODU body clockwise until clack! is heard and the ODU rotation stops. Fig. 15.10 and Fig. 15.11 show ODU housing final position for vertical and horizontal polarization respectively. Secure ODU body on the support system by tightening bolts (1) of Fig. 15.8.

4.

5.

1+1 version Fig. 15.12 - Apply silicon grease, type RHODOSIL PATE 4! to O-rings (1). Insert O-rings (1) and (6) into twist polarization disk (2). Vertical polarization Fix the disk on hybrid flange placing marker (4), on disk, close to V mark. Horizontal polarization Fix the disk on hybrid flange placing reference (4), on disk, close to H mark. Caution: Twist disk has two planes. Take care of position marker (4) on twist disk. The position of marker (4) plane should be in contact to hybrid like in figure. Tighten progressively and alternatively four screws (7) with four spring washers (8) with the following torque:

Tab. 15.1 Frequencies


from 18 to 38 GHz up to 15 GHz

Screw
allen screw M3 allen screw M4

Tool
allen key 2.5 mm allen key 3 mm

Torque
1 Nm 2 Nm

Fig. 15.13 - Fix hybrid to support system with four bolts (1) taking care of RT1/RT2 position shown by labels of Fig. 15.13. Tighten progressively and alternatively four bolts (1).

- 84 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

15.4.3 ODU installation


The installation procedure of the two ODUs is the same. 1. 2. Apply silicon grease e.g. RHODOSIL PATE 4 ! to the O-ring (4) of the Fig. 15.9 by protecting finger hands with gloves. Bring the ODU with the two hands and position the ODU handle at the bottom side. For 1+0 the ODU can assune position of Fig. 15.7 depending on the polarisation. For 1+1 the handle ODU position is always placed at the right side (horizontal polarization). Position the ODU body near the support system and align ODU side flange to antenna side flange (see Fig. 15.8). With respect to the flange alignment, turn the ODU body approx. 30 anti-clockwise and then insert the ODU body into the support and search for alignemnt between reference tooth on the support (see Fig. 15.8) and ODU body reference tooth (see detail of Fig. 15.9). When alignment is achieved, turn the ODU body clockwise until clack! is heard and the ODU rotation stops. Fig. 15.10 and Fig. 15.11 show ODU housing final position for vertical and horizontal polarization respectively for 1+0 version. Fig. 15.14 shows ODU housing final position for 1+1 version. Secure ODU body on the support system by tightening bolts (1) of Fig. 15.8.

3.

4.

5.

15.5 ANTENNA AIMING


Antenna aiming for 1+0 version and 1+1 version is the same. The antenna aiming devices allow to perform the following adjustments with respect to the starting aiming position: Horizontal Vertical 15 operating on the nut (3) shown in Fig. 15.15, only after having loosen the nuts (7), (8), (9), (10) of Fig. 15.16. 15 operating on vertical adjustment worm screw (2) shown in Fig. 15.15 only after having loosen nuts (1), (2), (11) of Fig. 15.16 and (4) of Fig. 15.15. For adjustment from 0 to +30 extract nut (1) Fig. 15.16 and position it in hole (4), extract nut (2) Fig. 15.16 and position it in hole (6). Operate on vertical adjustment worm screw (2) after having loosen nuts (1), (2), (11) of Fig. 15.16 and (4) of Fig. 15.15. For adjustment from 0 to -30 extract nut (1) of Fig. 15.16 and position it in hole (3), extract nut (2) of Fig. 15.16 and position it in hole (5). Operate on vertical adjustment worm screw (2) after having loosen nuts (1), (2), (11) of Fig. 15.16 and (4) of Fig. 15.15. For vertical adjustment some markers, every 10, are available on support. The bigger marker gives 0 starting aiming position. Once the optimum aiming position is obtained, tighten firmly the four nuts (1), (2), (11) of Fig. 15.16 and (4) of Fig. 15.15 for vertical adjustment and the four nuts (7), (8), (9), (10) of Fig. 15.16 for horizontal adjustment. Tighten with 15 mm wrench and 32 Nm torque.

- 85 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

15.6 COMPATIBILITY
The pole installation kit of the ODU unit in 1+0 and 1+1 configuration is compatible with integrated antenna complying with ZTE standard. Tab. 15.2 shows ZTE code for 0.2 m, 0.4 m, 0.6 m antennas. Tab. 15.3 shows the code of ANDREW antennas compatible with the pole installation kit.

Tab. 15.2 Frequency


13 GHz 15 GHz 18 GHz 19 GHz 23 GHz 26 GHz 28 GHz 38 GHz U00406 U00405 U00404 U00403 U00421 U00408 U00428 U00427 U00426 U00425 U00424

0.2 m antenna code

0.4 m antenna code

0.6 m antenna code

Tab. 15.3 Frequency


8 GHz 10 GHz 13 GHz 15 GHz 18 GHz 19 GHz 23 GHz 26 GHz 28 GHz 38 GHz VHLP1-180-SI1 VHLP1-190-SI1 VHLP1-230-SI1 VHLP1-260-SI1 VHLP1-280-SI1 VHLP1-380-SI1 VHLP2-180-SI1 VHLP2-190-SI1 VHLP2-230-SI1 VHLP2-260-SI1 VHLP2-280-SI1 VHLP2-380-SI1

0.4 m antenna code

0.6 m antenna code

15.7 GROUNDING
See Fig. 15.17. On ODU grounding can be connected with the available bolt spring washer and flat washers as shown.

- 86 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

1. Antenna 2. Calibrated Allen screw 3. Centering ring Fig. 15.1

- 87 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

1. Steel belt 2. Plastic blocks Fig. 15.2 Antislide strip

- 88 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

Fig. 15.3 Support mount on pole

- 89 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

1. Tooth Fig. 15.4

- 90 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

Fig. 15.5

- 91 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

15 mm wrench 32 Nm torque

A, B, C, D

Bolt slots

Antenna pole support Fig. 15.6installation Antenna on installation on pole support

- 92 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

Fig. 15.7 Position of the ODU handle depending on the polarization for 1+0. For 1+1 the polarization is always horizontal. Handle at the right side.

- 93 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

1 H

13 mm wrench 6 Nm torque

H H 1 1 H H

H H H: Reference tooth 1

Support system for ODU housing and reference toothreference in evidence Fig. 15.8 Support system for ODU housing and tooth in evidence

- 94 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

Fig. 15.9 ODU body reference tooth

- 95 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

Fig. 15.10 ODU housing final position for vertical polarization

- 96 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

Fig. 15.11 ODU Housing Final Position For Horizontal Polarization

- 97 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

Fig. 15.12 Hybrid and twist disk

- 98 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

1. Bolts 2. Spring washer

Fig. 15.13

Hybrid Mount On Pole Support

- 99 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

Fig. 15.14 ODU Housing Final Position For 1+1 Version

- 100 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

Fig. 15.15 Vertical and horizontal adjustments

- 101 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

1., 2., 3., 4. Horizpntal aiming block bolts 5., 6., 7. Vertical aiming block bolts 8., 11. Threaded hole for vertical aiming up to #30 9., 10. Threaded hole for vertical aimimg up to +30

Fig. 15.16 Antenna aiming block

- 102 -

Chapter 15 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA

1. Bolt 2. Spring washer 3. Flat washer 4. Earth cable collar 5. Flat washer Fig. 15.17 ODU grounding

- 103 -

Chapter 16 LINE-UP OF THE RADIO HOP

16 LINE-UP OF THE RADIO HOP


16.1 LINE-UP OF THE RADIO HOP
The line-up consists of the following steps: on site radio terminal installation (perform user connections and ODU installation as described in the relevant chapters) equipment switch-on (operate the ON/OFF switch on the IDU front) antenna alignment for maximum received RF signal level network element configuration check measurements.

16.1.1 Antenna alignment and received field measurement


Purpose of antenna alignment is to maximize the RF received signal level. Proceed as follows: connect a multimeter to BNC connector on the ODU for AGC measurement adjust antenna pointing as soon as the maximum AGC voltage value is achieved.

The relationship between AGC voltage and received field is shown by Fig. 16.1. The received field level has a tolerance of 4 dB in the full temperature range.

16.1.2 Network element configuration


A factory default address is assigned to each network element that must normally be reconfigured on site following the network administrator rules. To this purpose it is required to connect the PC, where the IE has been installed, to the network interfaces. This has to be done via Ethernet cable. Warning: the checks that follow require a good knowledge of the program use. The description of each menu and relevant windows are given by the program itself as help on line.

Perform the login to the equipment by entering: Equipment IP address in address bar of IE User ID (default: SYSTEM) Password: (default: MICR)

16.1.3 Radio Checks


It is advisable to perform the following measurements to check the correct operation of the radio hop:

- 104 -

Chapter 16 LINE-UP OF THE RADIO HOP

Transmitted power Received power RF frequency BER measurement

Fig. 16.1 Detected voltage versus RF received signal

- 105 -

Chapter 17 PERIODICAL CHECKS

17 PERIODICAL CHECKS
17.1 GENERAL
Periodical checks are used to check correct operation of the radio equipment without the presence of any alarm condition. The Web_CIT running on the PC are used for the purpose.

17.2 CHECKS TO BE CARRIED OUT


The following checks must be carried out: check of the trasmitted power; check of the received field strength (the reading must match the value resulting from hop calculations); check of bit error rate and hop performances.

For checking procedures, please refer to Web-CIT and relevant help-on line.

- 106 -

Chapter 18 COMPOSITION OF THE INDOOR UNIT

18 COMPOSITION OF THE INDOOR UNIT


18.1 GENERAL
The IDU is offered in main versions: 1+0 1+1

- 107 -

Chapter 19 COMPOSITION OF OUTDOOR UNIT

19 COMPOSITION OF OUTDOOR UNIT


19.1 GENERAL
The ODU consists of a mechanical structure that houses all the transceiver circuitry. In 1+1 version the connection to the antenna is performed through a passive hybrid. Both transceiver and hybrid are offered in different versions depending on the operating bands, the antenna configuration etc... A label attached on the ODU structure shows the most significant parameters as go/return frequency value, subband, operating band and part number. For example the P/N GA0001/001, shown by the label, identifies the following: 18 GHz G/R SB S/N 18 GHz operating band 1010 MHz go/return frequency value 1L operating subband low serial number month and year