Вы находитесь на странице: 1из 18

West Bengal Form No. 4977 FR From No.

15 (Final Payments must invariable be made on forms specially printed for the purpose, which should not be used for intermediate payments) P.W. Accounts Form 26 Running Accounts Bill B (See Rule 206, B.F.R.) (For Contractor This form provides for (1) Advance payments, (2) Secured Advances and (3) Payments for measured work) Cash BookDated Voucher . NO. . Name of Contractor : MAA SHURASI ENTERPRISE Name of Work : CONSTRUCTION OF KRISHAKBAZAR AT TEHATTA, NADIA. Serial No. of this Bill : ___________________________________________________ No. and date of his previous Bill for this Work : _______________________________ Reference of Agreement : 59/WBSMS/KB/NABARD/2012-13 Date of Written Order to commence work : 30.03.2013 Date of Actural completion of work : ________________________________________ These Two entries are not to be filled up in the case of piece work agreements. I -- Account of Work executed

Item No.

Item of work (grouped under sub-heads and sub-works of estimated

Rate

Unit

Quantity executed up to date as per measurement book

Payment on basis of actual measurements Up to Date Rs. Since previous Bill P Rs. P

Remarks with reasons for delay in adjusting payments shown in column (1)

Rs. 1 1 LAND DEVELOPMENT Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) . (c) (ii) With carried earth arranged by the contractor within a radius of 3 km. including cost of carried earth. TOTAL VALUE OF LAND DEVELOPMENT CONSTRUCTION OF BOUNDARY WALL Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom. Bailing out water as required complete. a. Depth of excavation not exceeding 1.500 m. Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) Cement concrete with graded stone ballast (40 mm. size) excluding shuttering. In Ground floor. (A) [Pakur Variety] (a) 6:3:1 proportion Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. Ordinary Cement concrete with graded stone chips(20 mm.size) excluding shuttering and reinforcement, if any, in ground floor. Pakur variety (1:1.5:3) Hire and labour charge for shuttering with centering and necessary staging up to 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs beams columns lintels curved or straight including fitting. Fixing and striking out after completion of works ( up to roof of ground floor). (a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge. Reinforcement reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of roads initial straightning and removal of loose rust (if necessary) cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 60gauge black annealed wire at very intersection, complete as per drawing and direction. for works in foundation basement and up to ground floor. 125 mm. thick brick work with 1st class bricks in cement mortar (4:1) Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating, nosing and drip course where necessary (ground floor). With 6:1 cement mortar 20 mm. thick plaster a) In Ground Floor Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the Engg-in-charge. (a) One coat. Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. (iii) Two coats. M.S. round or square bar grating of windos etc. fitted and fixed in holes of window frme and with intermediate flat bar stiffner( with necessary holes for the grating bars and with the ends turned and fixed to timber frame with necessary screws) complete , as directed

1.1 1 3 1

343.88

M3

3841.455 1,320,999.55 1,320,999.55

1.1 2

91.61 59.2

M3 M3

170.721 97.461

15,639.75

0.00

5,769.69

0.00

3 3.1 3.2 3.3 4 5 5.1 6

4193.28 310

M3 2 M

16.665 91.125

69,881.01 28,248.75

0.00 0.00

5707.93

93.325

532,692.57

0.00

6.1 7

276.67 72732.45

931.275 257,655.85 0.00 9.059

MT

658,883.26 665.7 M
2

0.00 0.00

8 9

601.42 400,365.29

9.1 9.2 9.3 10

M2

10.1 11

M2

11.1 12

M2 Qntl

13

14 15 3 4 1

1.1 2

5 6

Supplying fitting and fixing 600 mm (+- 30 mm) diametre R.B.T (Reinforced Barbed Tape Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T stands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as C clips R.B.T clips etc.) . M.S. gate of jail type as per approved design made of strong M.S. framework Supplying,Fitting & Fixing 3 Nos Gate with Glow Sign Board of approved specification. TOTAL VALUE OF CONSTRUCTION OF BOUNDARY WALL SINGLE ROOM SHOP GODOWN / KIOSK BLOCK 2 NOS Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding late rite or sandstone) including removing ,spreading or stacking the spoils within a lead of 75m. as directed . The items includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom. Bailing out water as required complete. A) Depth of excavation not exceeding 1500mm Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. including and watering ramming etc. layer by layer complete.(Payment to be made on basis of measurement of finished quantity of work) a) With earth obtained from excavation of foundation Filling in foundation or plinth by silver sand in layers not exceeding 150mm as directed and consolidating same by thorough saturation with water ramming complete including the cost of supply of sand .(Payment to be made on measurement of finished quantity) Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joint with powdered earth or local sand Cement concrete with graded stone ballast ( 40 mm. size)excluding shuttering. In ground floor, 6:3:1 proportion Ordinary cement concrete M20 mix (3:1.5:1) with graded stone chips (20mm. down )excluding shuttering and reinforcement if any, in ground floor as per IS 456-2000 a)Pakur/Chandi Variety Hire and labour charges for shuttering with centering and necessary staging upto 4m. using approved stout pr-pos and thick hard wood planks of approved thickness with required bracing for concrete, slabs,beam columns, lintel curved or straight including fitting, fixing and striking out after completion of works.(up to roof of ground floor) Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars stirrups, binders etc. including supply of rods,initial straightening and removal of loose rust (if necessary)cutting to requisite length,hooking and bending to correct shape ,placing in proper position and binding with 16gauge black annealed wire at every intersection, complete as per drawing and direction Brick work with 1st.class bricks in cement mortar (4:1) a) In Foundation & Plinth b) In Superstructure 125 mm. thick brick work with 1st class bricks in cement mortar (4 : 1) in ground floor with H.B. netting in every third layer in 33 above in any floor 40 mm. thick Damp Proof course with cement concrete (3:1.5:1) with graded stone chips 20 mm. normal size with water proofing compound of approved brand @ 1.00 kg./bag of cement including cost of materials over a coat of polymer based paint complete. Plaster(to wall,floor ceiling etc.) with sand and cement Mortar including rounding off or chamfer ing cormers as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary (ground flor) i) 10mm. th. plaster (1:4) ii) 15 mm. th. Plaster. (1:4) iii) 20mm. th. Plaster.(1:6) Neat cement punning about 1.5 mm. in wall dado,window , sills, floor,drain etc Artificial stone in floor, dado, staircase etc. with cementConcrete (4:2:1) with stone chips ,laid in panels as directed with topping made with ordinary or whie cement (asnecessary) and marble dust in proportion (2:1) including smooth finishing and rounding off corners and includingapplication of cement slurry before flooring woks,using cement @ 1.75 Kg./sq.m. all complete including all materials and labour. In ground floor.35mm. thick a)35mm. th. b) 35mm. th. on 1st floor c ) chequering on roof surface Suupplying, fitting and fixing steel rolling shutter profile type with 18 B.G. of approved type, steel latche section 75mm wide fitted with coil wire spring to necessitate the fitting of required No. of C.I. pulleys on heavy type solid drawn seamless steel tube complete with locking arrangement both inside and outside specially built up side guide channels including providing a hood for the steel rolling shutter in the room,painting two cats of approved aluminium paint over a coat of red lead primer complete Applying bonding agent with synthetic multifunctional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent :4 water : 6 cement) (100 gm./Sqm.) Supplying, fitting approved type ventilator in position after cutting holes in walls, setting in cement mortar, mending damages to wall and plaster and two coats of paint of approved brand and shade. R.C.C ventilator 20mm th. up to 0.10Sqm. area. Supplying dividing 3mm. th. glass strip fitted and fixed with cement mortar 3:1 in patent stone floor complete as per direction of Engineerin-Charge. 25mm. wide strip.

Mtr.

Qntl. Nos

91.61 59.2

M3 M3

123.37 84.886

11,301.93

11,301.93

5,025.25 728.53 M3 151.588

5,025.25

110,436.41 310 M2
3

110,436.41

208.44 64,616.40 64,616.40 77,357.63

4193.28 5707.93

18.448 77,357.63 38.058 217,232.40 217,232.40

M3
2

326.98

215.32

70,405.33 72732.45 M.T. 3.249

70,405.33

9 9.1 9.2 10

4897.2

M M3 2 M M2

40.09

236,307.73 0.00 196,309.16

236,307.73 0.00 196,309.16

11

12

12.1 12.2 12.3 13 15

M2 M2 M2 M2

15.1 15.2 15.3 16

M2 M2 M2 M2

18

M2

19

Each

20

Mtr

22

Supplying, fitting & fixing U.P.V.C pipes a-Type and fittings confirming to IS:13592-1992 with all necessary clamps nails including making hole s in walls, floor, etc. and cutting trenches in any soil, through masonry concrete structures etc. if necessary and mending good damages including jointing with jointing materials - als complete. 110 mm. dia. Applying cement primer of approved quality and brand on plastered or concrete surface to receive cement based paint including scrapping and preparing the surface thoroughly, complete as per direction of Engineer-in-charge. (Manufacturers specification to be followed) Applying decorative cement based paint approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturers specification . In ground floor. Painting with best quality synthetic enamel paint of approved make and brand including smoothning surface by sand papering etc. including using of approved putty etc. on the surface of necessary materials. On steel surface two coats with any shade except white Colour washing with any shade with Stainers, as required including cleaning and smoothening surface thoroughly . i) internal surface(all floors) b) Two coats TOTAL VALUE OF SINGLE SHOP CUM GODOWN 200 MT CAPACITY AUCTION HALL Earth work in excavation of foundation trenches or drains in all sorts of soil ( including mixed soil but excluding laterite or sand stone ), including removing, spreading or stacking the spoils with in a lead of 75 m. as directed and including trimming the side of trenches, leveling, dressing the bottom, bailing out water etc. as required complete.(a) Depth of excavation not exceeding 1500 mm Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) Filling in foundation and plinth by silver sand in layers not exceeding 150 mm as directed and consolidating same by through saturation with water ramming complete, including the cost of supply of sand.(Payment to be made on measurement of finished quantity) Cement concrete with graded stone ballast (40 mm. size) excluding shuttering. In Ground floor. (A) [Pakur Variety] (a) 6:3:1 proportion Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. Ordinary Cement concrete [ Mix 3 : 1.5 : 1 ] with graded stone chips(20 mm.size) excluding shuttering and reinforcement, if any, in ground floor.as per Is Codes a) Pakur Variety a)In foundation and plinth and Ground floor Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) . (a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge. Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (i) Tor steel/Mild steel (a) For works in foundation, basement and upto roof of ground floor / upto 4m. Brick work with 1st class bricks in cement mortar (6:1) . a) foundation and plinth Brick work with 1st class bricks in cement mortar (6:1) . In superstructure, Ground Floor Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) . (i) With 6:1 cement mortar 20 mm thick with cement mortar(internal) (ii) With 4:1 cement mortar, (b) 15 mm. thick plaster(External) in ground floor Neat cement punning Supplying and laying Polythene Sheet (150gm/sq.m.) over damp proof course or below flooring or roof terracing or in foundation trenches. Artificial stone in floor, dado, staircase etc. with cement concrete (4:2:1) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (2:1) including smooth finishing and rounding off corners and including application of cement slurry before flooring works,using cement @1.75 kg./sq.m. all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted) with ordinary cement.Using grey cement.

Mtr

23

M2

24

25

M2

26 26.1 26.2 4 5 1

M2

91.61

115.07

10,541.29 2 59.2 M3 52.77

3,947.20

3,124.04 827.53 M3 352.45

483.72

291,659.64 4 4.1 4.2 4.3 5 6

64,987.59

4193.28 310

M3 M2

30.84 404.10

129,312.37 125,270.07

112,191.21 104,085.60

6.1 6.2 7

5707.93

M3

67.16

383,327.46

176,820.26

7.1 8

276.67

M2

576.74 159,566.66 97,260.57

8.1 8.2 9 9.1 10 10.1 11

72732.45

MT

8.28 602,515.62 275,874.18 184,795.84 108,911.42

4897.2 5051.55

M M

62.49 21.56

306,001.54 108,911.42

11.1 11.2 12 12.1 13 14

M2 M2 M2

15

15.1 15.2

M2

16 17

(i) Chequering M.S. structural works with hallow section [ TATA make sq.mtr. Or rectangular shape ] conforming to IS: 806-1957 & IS: 1161- 1958 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in- charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages (such as electricity charges, labour insurance charges etc. complete Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weigt of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i] For roof truss works :-a] Span upto 12 mtr. Supplying corrugated Zinc Alluminium alloy coloured coated steel sheet ( 0.45 mm thk.) on roof (excluding supporting frame work fitted, fixed with self tapping pressure fastning bolt of 12-24 mm dia with necessary EPDM and colour coated steel washer with 150 mm end laping and one corrugation on side laping complete with all incidental work. (The work is to be carried out as per literature as specification laid down in the "Durashine TM" products and also as per the direction of Engineer-in-charge. with 0.45 mm thk sheet. Supplying, Fitting Corrugated Zinc Alluminium alloy coloured sheet ridging 225mm. lap each way and fitted with necessary bolts ,screws, washers etc. complete. With 0.45 mm sheet with lap of 30 cm.each way. Galvanised or painted wind-tie made of M.S. flats, fitted and fixed complete including cost of necessary fittings. (b) made with 50mm. X 10mm. Flats Applying cement primer of approved quality after preparing the surface including scraping the same throughly Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. (iii) Two coats. Painting with ready mixed red lead paint of approved make and brand . (b) Two coats Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary . (b) On steel or other metal surface : With super gloss (hi-gloss) (iv) Two coats (with any shade except white) Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed. (ii) 20 mm dia bolt. (c) 750 mm long TOTAL VALUE OF 200 MT CAPACITY AUCTION HALL ADMINISTRATIVE BUILDING Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete (a) Depth of excavation not exceeding 1,500 mm. Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation. Filling in foundation and plinth by silver sand in layers not exceeding 150 mm as directed and consolidating same by through saturation with water ramming complete, including the cost of supply of sand.(Payment to be made on measurement of finished quantity) Antitermte treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrefos emulsifiable concentrates ( 1 concentration) with water by weight at the rate of 5 Litres per sq. m. of the surfac before sand bed or subgrade is laid. Hole upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diaetre mild steel rod on the surface to facilate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in 6:4. of code IS-6313 (part -II) 1981. ( Mode of measurment will be plan area of plinth treated.) a) Anti-termite treatment to the outside of foudations with chemical emulsion by admixing chloropyrifos emulsifiable concentrates (1concentration) with water by weight including cutting shallow channel by excavating soil along and close to the wall face ensuring uniform dispersal of the chemical emulsion to a depth of 300mm. from the ground level by rodding with 12mm. dia. M.S. rod at 150mm.interval in the channel. 1.75 litres of chemical emulsion per metre length shall be used and a balance quantity of 0.5 litres of the chemical emulsion per running metre shall then be used to treat the back fill earth by directing the spray of the imulsion towards the wall surface. The entire work is to be carried out as per specification laid down in para 4.3.1.1 of code IS-6313 (Part-III) 1981.

17.1

17.2 18

MT M2

19

Mtr.

20 20.1 21 22

Mtr. M2

22.1 23 23.1 24

M2

24.1 24.2 24.3 25

25.1 25.2 5 6 1

Nos.

1.1 2

91.61

M3

78.639

7,204.12

0.00

2.1 3

59.2 728.53

M3 M3

42.988 208.125

2,544.89

0.00

151,625.31 4 96.99 M
2

0.00

176.85

17,152.68

0.00

5.1 6

7 8 8.1

9.1 9.2 9.3 9.4 10

Post construction measures : Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge. Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. Cement concrete with graded stone ballast (40 mm. size) excluding shuttering. In Ground floor. (A) [Pakur Variety] (a) 6:3:1 proportion Ordinary Cement concrete [ Mix 3 : 1.5 : 1 ] with graded stone chips(20 mm.size) excluding shuttering and reinforcement, if any, in ground floor.as per Is Codes a) Pakur Varietya a) In foundation and plinth b) Super Structure, Ground Floor. ii)First Floor iii)Above First Floor Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) . (c) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete work. a) In foundation and plinth b) Super Structure i) Ground Floor. ii) First Floor iii) Above First Floor Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (i) Tor steel/Mild steel (a) For works in foundation, basement and upto roof of ground floor / upto 4m. b) First Floor c) Above First Floor Brick work with 1st class bricks in cement mortar (6:1) . a) foundation and plinth b) In superstructure i) Ground Floor ii) First Floor iii) Above First Floor 125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in ground floor including for using approved H.B netting in every third layer above in any floor a) Ground Floor b) First Floor c) Above First Floor 25mm. thick damp proof course with cement concrete with stone chips (3:1.5:1) [with graded stone aggregate 10mm nominal size]and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st.coat after 4 to 5 days of cocrete laying and 2nd. coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately). (chequering not required over concrete or painted surface). Supplying and laying Polythene Sheet (150gm/sq.m.) over damp proof course or below flooring or roof terracing or in foundation trenches. 20 mm. thick (finished) terrazo work with precast tiles set in 20 mm thick cement mortar (3:1) and sides with admixture of pigment and white/grey cement as necessary in floor, dado, skirting, staircase etc. laid in panels or in patterns including high polishing, raking out joints or roughening of concrete surface & application of cement slurry before flooring works using cement @1.75 kg./sq.m. all complete including all materials & labour. (A) 9 mm. thick terrazo topping, laying and finished to 6 mm. thick after final grinding with 0 to 7 mm. size mosaic chips. (i) In ordinary grey colour a) Ground Floor b) First Floor Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide of required to match colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. A) Floor With Sand Cement Morter (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sq.m & joint filling using white cement slurry @ 0.20 kg/Sq.m. (b) Area of each tile above 0.09 sq.m. ii) Other than Coloured decorative including white B) Wall

59.55

Mtr M3

57.75

3,439.01

0.00

310

254.197 78,801.07 0.00

4193.28

M3

22.041 92,424.08 0.00

5707.93 5707.93

M3 M
3

37.204 212,357.83 40.108 228,933.66 228,933.66 0.00

M3 M3

10.1 10.2 10.3 10.4 10.5 11

326.98 326.98

M2 2 M M2 M2

232.705 365.752

76,089.88 119,593.59

0.00 119,593.59

11.1 11.2 11.3 11.4 12 12.1 12.3 12.4 12.5 13

72732.45

MT MT MT

10.072 732,561.24 362,862.19

4897.2 5051.55

M3 3 M M3 M3

24.23 30.548

118,659.16 154,314.75

0.00 154,314.75

13.1 13.2 13.3 14

665.7

M2 2 M M2 M2

88.571

58,961.71

58,961.71

15

M2

16

16.1 16.2 16.3 16.4 17

M2 M2

17.1 17.2

17.3 17.4 17.7

M2

17.8

17.9 17.1 18

18.1 18.2 19

19.1 19.2 20

20.1 20.2 20.3 20.4

20.7 20.8 21

With Sand Cement Morter (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sq.m & joint filling using white cement slurry @ 0.20 kg/Sq.m. (a) Area of each tile upto 0.09 sq.m. ii) Other than Coloured decorative including white Supplying and laying true to line and level 20 mm/ 25 mm. thick precast roof tiles made of cement conc. with stone chips as per approved strength and density set in 25 mm. (Ave) thick cement mortar (1:3) and filling up joint (3 mm. wide) with cement mortar (1:1) applying cement slurry @ 1.75 kg per sq.m. back of tiles and then settting close the precast tiles, finishing up the joints with slurry already laid and finally finishing the top surface including providing 150 mm. high skirting with the same tiles flushed with the inside surface of parapet wall,finishing the mouth of rain water pipes curving etc. as necessary complete as per direction of the Engineer-in-charge. (Levelling if necessary may be paid separately). (a) For 20 mm. thick precast tiles (cement 14.6 kg/Sq.m for underlayer) At First Floor Roof M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. a) Ground Floor b) First Floor Supplying fting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straitning if required, fixing lugs in cement concrete ( 4:2:1) with stone chips 19 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Flash butt welded windows and ventilators (no shop priming will be allowed to facilitate inspection of workmanship) Without integrated grills. b) Openable steel windows as per IS sizes with side hunge shutters and horizotal glazing bars, with or outhout fixed type ventolators ( the extra rate admissible for the openable portion only.) iv)Two point nose steel handle including fitting and fixing. ii) steel peg stay 300 mm long including fitting and fixing. Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracigs properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. Wood work in door and window frame fitted and fixed complete icluding a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron butt Hinges amd M.S.clamp. (d) Sal : Local. M.S. clamp for fixing door and window frame made of flat bent bar, end bifurcated, fixed in cement concrete with stone chips (4:2:1) fitted and fixed complete as per direction. (a) 40mm. X 6mm, 250mm. Length. Supplying 'Brass floor door stopper, including fitting and fixing complete. Anodised aluminium barrel/ tower/ socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws. (ix) 300mm long x 10mm dia. bolt. Anodised aluminium Aldrop/Sliding bolts of approved quality manufactgured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (iii) 300mm x 16mm dia. bolt. Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws. (v) 100 x 63 x 3.2 mm. Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete. (a) With continuous plate base (hexagonal/round rod) (vii) 150mm grip x 12mm dia rod. Supplying 'Godrej' mortice lock with latch and keys 6 levers, including fitting and fixing complete. Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete. (a) Heavy type (I.S.I. size 3) Providing, fitting & fixing glass vision panel made of 2 nos 3mm thick clear float glass of approved quality including making provision on door shutter and fixed in position withy wooden mould bead of size 12mm x 12mm including cost of all materials and labour. Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, inclkuding fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. 32 mm thick shutters (single leaf)

M2

M2

Qtl. Qtl.

M2 M2 2 M

22

22.1 23

23.1 24 25

nos. Nos

25.1 26

Nos

26.1 27

Nos

27.1 28

Nos

28.1 28.2 29 30 30.1 31

Nos Nos

Nos Nos

32

32.1

M2

33

34

34.1

35

35.1 35.2 35.3 35.4 35.5 35.6 35.7 35.8 35.9 35.1 35.11 35.12 35.13 35.14 35.15 36 37

37.1 37.2 38

38.1 38.2 38.3 39

40

41

41.1 41.2 41.3 41.4 41.5 41.6 41

41.1 42

42.1 42.2 42.3 42.4 42.5

Supplying fitting and fixing in position approved P.V.C. door frame (matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/- 0.2mm) horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.2 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials taxes and all other incidental charges complete. Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59mm x 30mm section with 2.0mm (+/- 0.2mm) wall thickness, horizontal & vertical section shall be fixed to each other by self tapping screws and one solid polymeric / M.S. galvanised tubular L-shaped brackets 100mm x 200mm in each corner of the shutter frame for placing hinges, polymer based multicavity holoow section of 120 mm x 30 mm with 2.0mm (+/0.2mm) wall thickness will be fitted in the middle as lock rail, reinforced by solid polymer bar of 200mm long at both ends & screws for both sides. The section frame will then be fitted in by PVC panels of size 100mm x 25mm, with wall thickness 1.2mm (+/- 0.2mm) and 2 nos. of 6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials and labour hire of tools and plants and appliencies. Carriage of all materials taxes and all other incidental charges complete.The rate is exclusive of cost of hinges, hasp bolt, tower bolt, door ring etc Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) . (i) With 6:1 cement mortar 20 mm thick with cement mortar(internal) I) Ground Floor II) First Floor III) Above First Floor (ii) With 4:1 cement mortar (b) 15 mm. thick plaster(External) I) Ground Floor II) First Floor III) Above First Floor (ii) With 3:1 cement mortar 10 mm thick with cement mortar (ceiling) I) Ground Floor II) First Floor III) Above First Floor Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. Acrylic distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacture's specification) including cleaning and smoothning surface . Internal Surface all floors Two coats. Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. I) Ground Floor II) First Floor III) Above First Floor Priming one coat on timber, plastered surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary . On timber surface With super gloss (hi-gloss) (iv) Two coats (with any shade except white) On Steel Surface With super gloss (hi-gloss) (iv) Two coats (with any shade except white) Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete ( in all floors for internal wall & upto 6 m height for external wall ). (ii) 3 mm. thick Supplying, fitting and fixing UPVC pipes A - type and fittings conforming to IS 13592-1992 with all necessary clamps nails including making holes in walls, etc. and cutting trenches in any soil, through masonry concrete structure etc. if necessary and mending good damages including jointing with jointing materials ( Spun yarn, valamoid / bitumen / M. seal etc.) complete. A) UPVC Pipes 160mm dia B) UPVC Fittings Bend 87.5 degree 160 mm dia Shoe 160 mm dia

Mtr.

M2

M2 M2 M2

M2 M2 2 M

M2 M2 M2 2 M

M2 M2 M2 M2 M2

M2

M2

M2

Mtr. Nos Nos

43

Spplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS 732-1983 and Is: 1285- 1975; Annodized (with required film thickness and specified color / natural) matt finished conformating to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - InCharge. (Payment will be made on finished length of the work). (A) 10 - 12 micron thickness anodizing film (K) Movable door shutter Door frame- top & Sides Shutter Top rail Bottom Rail Lock rail Vertical Glazing Clip Labour charge for fabrication and installation of composite door, window , partitions made from annodized extruded alloy aluminium sections for the following units. Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, adhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry set neoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge. The rate includes the hire charge of all tools and plants, adhesive, joineries such as screw, cleate angle etc. but excluded the cost of extruded sections, glass, neoprene / EPDM gasketing, locking arrangement, weather gasketing / wool pile, floor spring, top pin, handle tower bolt, glazing clips etc. (10 rate reduction has to be made for swing doors or partitions where floor sping is not uses. 10 enhensement of rate is to be made where door frame of extruded aluminium sections has to be fitted and fixed to masonry wall. 5 rate enhencement may be allowed for double leaf swing door. Payment shall be made for the shutter area only exept where door frame is fixed the entire opening shall be taken to consideration.Payment for door frame sections are to be paid seperately). Supplying heavy duty hydraulic double action floor spring along with top pin set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge. Supplying concealed type heavy duty PVC headed aluminium tower bolt for double leaf doors as per approved make and brand as per direction of EIC. (d) 450 mm long Supplying maruti lock (100mm) . Supplying EPDM gusket of approve make and brand as per direction of Engineer in charge. Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 6mm thick class glass Supplying fitting approved type ventilator in position after cutting holes in walls, setting in cement mortar mending damages to wall and plaster and two coats of paint of approved brand sand shade. Payment of mending two damages of wall & plaster and painting to be made separately. (b) R.C.C ventilator of 20 mm. thick (i) Upto 0.10 sq.m. area Supplying fitting fixing fan hook for ceiling with 1 metre long 16 mm dia rod complete including mending damages. Construction of 600mm wide plinth prtection work around the external periphery of the building comprising earth work in excavation not exceeding 150mm in depth. Single line brick edging single brick flat soiling, 75mm thick PCC (1:3:6) with graded jhama khoa (30mm size) finished smooth with neat cement punning in one operation. The finished top surface shall have a slope of 1 in 20. TOTAL VALUE OF ADMINISTRATIVE BUILDING KISHAN SAHAYAK KENDRA Earth work in excavation of foundation trenches or drains in all sorts of soil ( including mixed soil but excluding laterite or sand stone ), including removing, spreading or stacking the spoils with in a lead of 75 m. as directed and including trimming the side of trenches, leveling, dressing the bottom, bailing out water etc. as required complete. (a) Depth of excavation not exceeding 1,500 mm. Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) a) With earth obtained from excavation of foundation Filling in foundation and plinth by silver sand in layers not exceeding 150 mm as directed and consolidating same by through saturation with water ramming complete, including the cost of supply of sand.(Payment to be made on measurement of finished quantity) 91.61

43.1 43.2 43.3 43.4 43.5 43.6 43.7 43.8 43.9 44

Mtr. Mtr. Mtr. Mtr. Mtr. Mtr.

44.1

44.2

M2

45

Nos

46

46.1 47 48 49 49.1 50

Nos Pair Mtr.

M2

50.1 50.2 51 52

Nos Nos Mtr.

6 7 1

1.1 2

M3

147.156

13,480.96

3,578.74

2.1 3

59.2 728.53

M3 M3

73.917 258.374

4,375.89

424.17

188,233.21

50,243.07

7 8

9.1 9.2 9.3 10

(c) Antitermte treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrefos emulsifiable concentrates ( 1 concentration) with water by weight at the rate of 5 Litres per sq. m. of the surfac before sand bed or subgrade is laid. Hole upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diaetre mild steel rod on the surface to facilate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in 6:4. of code IS-6313 (part -II) 1981. ( Mode of measurment will be plan area of plinth treated.) Pre- Constructional Anti- termite measures a) Anti-termite treatment to the outside of foudations with chemical emulsion by admixing chloropyrifos emulsifiable concentrates (1%concentration) with water by weight including cutting shallow channel by excavating soil along and close to the wall face ensuring uniform dispersal of the chemical emulsion to a depth of 300mm. from the ground level by rodding with 12mm. dia. M.S. rod at 150mm.interval in the channel. 1.75 litres of chemical emulsion per metre length shall be used and a balance quantity of 0.5 litres of the chemical emulsion per running metre shall then be used to treat the back fill earth by directing the spray of the imulsion towards the wall surface. The entire work is to be carried out as per specification laid down in para 4.3.1.1 of code IS-6313 (Part-III) 1981. Post construction measures : Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge. Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. Cement concrete with graded stone ballast (40 mm. size) excluding shuttering. In Ground floor. (A) [Pakur Variety] Ordinary Cement concrete [ Mix 3 : 1.5 : 1 ] with graded stone chips(20 mm.size) excluding shuttering and reinforcement, if any, in ground floor.as per Is Codes a) Pakur Variet a) Foundation and plinth b) Super structure i) Ground Floor ii) First Floor iii) Above First Floor Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) . (c) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete work. i) Foundation upto plinth ii) Super Structure a) Ground Floor (ii) First Floor (iii) Above First Floor Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4m. i) Tor steel/Mild steel ii) First Floor iii) Above First Floor Brick work with 1st class bricks in cement mortar (6:1) . a) foundation and plinth b) Super structure : i) Ground Floor ii) First Floor iii) Above First Floor 125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in ground floor including for using approved H.B netting in every third layer above in any floor (a) Ground Floor (b) First Floor c ) Above First Floor 25mm. thick damp proof course with cement concrete with stone chips (3:1.5:1) [with graded stone aggregate 10mm nominal size]and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st.coat after 4 to 5 days of cocrete laying and 2nd. coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately). (chequering not required over concrete or painted surface). 20mm thick (finished) terazzo work, cast-in-situ in floor and 20mm thick (finished) in dado, skirting, staircase etc. laid in panels or pattern as directed and necessary terazzo topping with mosaic chips including rounding off corners and high polishing etc. complete as per specification laid down in IS: 2114_1962 & application of cement slurry before flooring works using cement @1.75kg/sqm all complete including all materials and labour. (A) 9mm thick terrazo topping laying and finished to 6mm thick after final grinding with 0 to 7mm size mosaic chips (i) in ordinary gray colour In Ground floor

96.99

159.363

15,456.62 59.55 Mtr. 62.05

0.00

3,695.08 M
3

0.00

0.00 310 4193.28 M2 M3 M3 368.60 114,266.31 27.68 116,061.60 5707.93 51.92

0.00 34,641.88

21,838.60

296,378.56 5707.93 M3 M3 3 M 53.15 303,370.77

43,962.48 303,370.77

10.1 10.2 10.3 10.4 10.5 11

326.98 326.98

M2 M2 Mtr. Mtr.

262.86 462.30

85,948.33 151,161.22

0.00 151,161.22

11.1

72732.45

MT

12.42 903,191.56 499,817.40

11.2 11.3 12 12.1 12.2 12.3 12.4 12.5 13

MT MT 4897.2 5051.55 M3 M M3 M3
3

62.68 26.30

306,966.29 132,860.82

167,910.30 132,860.82

13.1 13.2 13.3 14

665.7

M2 Mtr. Mtr. Mtr.

214.46

142,766.69

142,766.69

15

15.1 15.2 15.3

M2

15.4 16

16.1 16.2 17

17.1 17.2

17.3 17.4 17.6 17.7

17.8 17.9 18

18.1 19

19.1 19.2 19.3 20

First Floor Artificial stone in floor, dado, staircase etc. with cement concrete (4:2:1) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (2:1) including smooth finishing and rounding off corners and including application of cement slurry before flooring works,using cement @1.75 kg./sq.m. all complete including all materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted) with ordinary cement.Using grey cement.(iii) 35 mm. thick In Ground floor First Floor Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide of required to match colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. A) Floor With Sand Cement Morter (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sq.m & joint filling using white cement slurry @ 0.20 kg/Sq.m. (b) Area of each tile above 0.09 sq.m. ii) Other than Coloured decorative including white B) Wall With Sand Cement Morter (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sq.m & joint filling using white cement slurry @ 0.20 kg/Sq.m. (a) Area of each tile upto 0.09 sq.m. ii) Other than Coloured decorative including white Supplying and laying true to line and level 20 mm/ 25 mm. thick precast roof tiles made of cement conc. with stone chips as per approved strength and density set in 25 mm. (Ave) thick cement mortar (1:3) and filling up joint (3 mm. wide) with cement mortar (1:1) applying cement slurry @ 1.75 kg per sq.m. back of tiles and then settting close the precast tiles, finishing up the joints with slurry already laid and finally finishing the top surface including providing 150 mm. high skirting with the same tiles flushed with the inside surface of parapet wall,finishing the mouth of rain water pipes curving etc. as necessary complete as per direction of the Engineer-in-charge. (Levelling if necessary may be paid separately). (a) For 20 mm. thick precast tiles (cement 14.6 kg/Sq.m for underlayer) At First Floor Roof M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr Area of windows in Gr. Floor Area of window in 1st Floor Supplying fting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straitning if required, fixing lugs in cement concrete ( 4:2:1) with stone chips 19 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Ground Floor (b) Openable steel windows as per IS sizes with side hunge shutters and horizotal glazing bars, with or outhout fixed type ventolators ( the extra rate admissible for the openable portion only.) Ground Floor iv)Two point nose steel handle including fitting and fixing. ii) steel peg stay 300 mm long including fitting and fixing. Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracigs properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. Ground floor (a) Supplying fitting and fixing steel rolling shutter profile type with 18 B.G . Of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. Wood work in door and window frame fitted and fixed complete icluding a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron butt Hinges amd M.S.clamp. (d) Sal : Local. M.S. clamp for fixing door and window frame made of flat bent bar, end bifurcated, fixed in cement concrete with stone chips (4:2:1) fitted and fixed complete as per direction. (a) 40mm. X 6mm, 250mm. Length. Supplying brass floor door stopper including fitting & fixing complete Anodised aluminium barrel/ tower/ socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws. (i) 300 mm x 10 mm dia

M2 M2

M2

M2

M2

Qntl Qntl.

20.1 20.3 20.4 21

M Nos. Nos.

21.1 22

M2 M2

23

23.2 24

M3

24.1 25 26

Nos. Nos.

26.1

Nos.

27

27.1 28

28.1 29

29.1 29.2 30

Anodised aluminium Aldrop/Sliding bolts of approved quality manufactgured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (i) 300 mm x 16 mm dia Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws. (v) 100mm x 63mm x 3.2mm Anodised aluminium D-type handle of approved quality manufactured from extruded section conforming to IS. Specification (I.S.230/72) fitted & fixed with complete. (a) With continuous plate base (hexagonal/round rod) (v) 150mm grip x 12mm dia road Providing, fitting & fixing glass vision panel made of 2 nos 3mm thick clear float glass of approved quality including making provision on door shutter and fixed in position withy wooden mould bead of size 12mm x 12mm including cost of all materials and labour. a) 300mm x 150mm Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, inclkuding fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (i) 32mm thick shutters (single leaf) Supplying fitting and fixing in position approved P.V.C. door frame (matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/- 0.2mm) horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.2 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials taxes and all other incidental charges complete. Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59mm x 30mm section with 2.0mm (+/- 0.2mm) wall thickness, horizontal & vertical section shall be fixed to each other by self tapping screws and one solid polymeric / M.S. galvanised tubular L-shaped brackets 100mm x 200mm in each corner of the shutter frame for placing hinges, polymer based multicavity holoow section of 120 mm x 30 mm with 2.0mm (+/0.2mm) wall thickness will be fitted in the middle as lock rail, reinforced by solid polymer bar of 200mm long at both ends & screws for both sides. The section frame will then be fitted in by PVC panels of size 100mm x 25mm, with wall thickness 1.2mm (+/- 0.2mm) and 2 nos. of 6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials and labour hire of tools and plants and appliencies. Carriage of all materials taxes and all other incidental charges complete.The rate is exclusive of cost of hinges, hasp bolt, tower bolt, door ring etc PVC door shutter-30mm thick Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) . (i) With 6:1 cement mortar 20 mm thick with cement mortar(internal) i) Ground Floor ii) First Floor iii) Above First Floor (ii) With 4:1 cement mortar (b) 15 mm. thick plaster(External) i) Ground Floor ii) First Floor iii) Above First Floor (ii) With 4:1 cement mortar 10 mm thick with cement mortar (ceiling) i) Ground Floor ii) First Floor iii) Above First Floor Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. Colour washing with any shade with Stainers, as required including cleaning and smoothening surface thoroughly . (i) Internal surface (all floors) (b) Two coats (on new works only). Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. (iii) Two coats. a) Ground Floor b) First Floor c) Above First Floor Priming one coat on timber, plastered surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc.

Nos.

Nos.

Nos.

30.1 31

Nos.

31.1 32

M2 Mtr.

33

33.1

33.2 34

M2

34.1 34.2 34.3 34.4 34.5 34.6 34.7 34.8 34.9 34.1 34.11 34.12 34.13 34.14 34.15 35 36 36.1 36.2 37

M M2 M2

M2 M2 M2

M2 M2 M2 M2

%M2

37.1 37.2 37.3 37.8 38

Mtr. Mtr. Mtr. 2 M

39

40

40.1 40.2 40.3 40.4 40.5 40.6 41

41.1 42

42.1 42.2 42.3 42.4 42.5 42.6 42.7 43

43.1 43.2 44 45

Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary . On timber surface With super gloss (hi-gloss) Two coats (with any shade except white) On Steel Surface With super gloss (hi-gloss) (iv) Two coats (with any shade except white) Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete ( in all floors for internal wall & upto 6 m height for external wall ). (ii) 3 mm. thick Supplying, fitting and fixing UPVC pipes A - type and fittings conforming to IS 13592-1992 with all necessary clamps nails including making holes in walls, etc. and cutting trenches in any soil, through masonry concrete structure etc. if necessary and mending good damages including jointing with jointing materials ( Spun yarn, valamoid / bitumen / M. seal etc.) complete. (A) UPVC Pipes 160 mm Dia (B) UPVC Fittings Bend 87.5 degree (ii) 160 mm dia (d) Shoe Shoe - 160 mm dia Supplying fitting approved type ventilator in position after cutting holes in walls, setting in cement mortar mending damages to wall and plaster and two coats of paint of approved brand sand shade. Payment of mending two damages of wall & plaster and painting to be made separately. (b) R.C.C ventilator of 20 mm. thick (i) Upto 0.10 sq.m. area Supplying fitting fixing fan hook for ceiling with 1 metre long 16 mm dia rod complete including mending damages. Construction of 600mmwide plinth protection work around the external periphery of the building comprising earth work in excavation not exceeding 150mm. In depth, single line brick edging, single brick flat soiling, 75mm thick PCC (1:3:6) with graded jhama khoa (30mm. size) finished smooth with neat cement punning in one operation. The finished top surface shall have a slope of 1 in 20. TOTAL VALUE OF KRISHAN SAHAYAK KENDRA OPEN MARKET SHED Earth work in excavation of foundation trenches or drains in all sorts of soil ( including mixed soil but excluding laterite or sand stone ), including removing, spreading or stacking the spoils with in a lead of 75 m. as directed and including trimming the side of trenches, leveling, dressing the bottom, bailing out water etc. as required complete.(a) Depth of excavation not exceeding 1500 mm Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) Cement concrete with graded stone ballast (40 mm. size) excluding shuttering. In Ground floor. And foundation with proportion (1:3:6) Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. Ordinary Cement concrete [ Mix 3 : 1.5 : 1 ] with graded stone chips(20 mm.size) excluding shuttering and reinforcement, if any, in ground floor.as per Is Codes a) Pakur Variety Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) . (c) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete work. Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor Brick work with 1st class bricks in cement mortar (6:1) . a) foundation and plinth b)Ground Floor Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) . (i) With4:1 cement mortar 15 mm thick with cement mortar(internal) Ground Floor Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.

M2

Mtr Nos.

Nos.

Nos. Nos. Mtr.

7 8 1

91.61

M3

88.060

8,067.18 2 59.2 M3 43.663

2,947.55

2,584.85 4193.28 M3 M2 20.151 84,498.79

527.29

70,799.34 67,700.90

4 5

310

269.610 83,579.10

5.1 6

5707.93

M3

47.400

270,555.88

124,158.89

6.1 7

326.98

M2

333.140 108,930.12 51,146.21

7.1 8 8.1 8.2 9

72732.45 5217.45 5370.75

MT M M3
3

5.482 45.294 5.500

398,719.29 236,319.18 29,539.13

169,321.14 149,213.85 29,539.13

9.1 9.2 10

M2 M3

11

11.1 11.2 12

Artificial stone in floor, dado, staircase etc. with cement concrete (4:2:1) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (2:1) including smooth finishing and rounding off corners and including application of cement slurry before flooring works,using cement @1.75 kg./sq.m. all complete including all materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted) with ordinary cement. (iii) 35 mm. thick Supplying and laying Polythene Sheet (150gm/sq.m.) over damp proof course or below flooring or roof terracing or in foundation trenches. M.S. structural works with hallow section [ TATA make sq.mtr. Or rectangular shape ] conforming to IS: 806-1957 & IS: 1161- 1958 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in- charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages (such as electricity charges, labour insurance charges etc. complete Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weigt of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. a) span up to 12 Mtr. i] For roof truss works :Supplying corrugated Zinc Alluminium alloy coloured coated steel sheet ( 0.45 mm thk.) on roof (excluding supporting frame work fitted, fixed with self tapping pressure fastning bolt of 12-24 mm dia with necessary EPDM and colour coated steel washer with 150 mm end laping and one corrugation on side laping complete with all incidental work. (The work is to be carried out as per literature as specification laid down in the "Durashine TM" products and also as per the direction of Engineer-in-charge. Supplying, Fitting Corrugated Zinc Alluminium alloy coloured sheet ridging 225mm. lap each way and fitted with necessary bolts ,screws, washers etc. complete. With 0.45 mm sheet with lap of 30 cm.each way.. Galvanised or painted wind-tie made of M.S. flats, fitted and fixed complete including cost of necessary fittings. (c) Made with 50.0 mm. X 10.0 mm. flats Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the Engg-in-charge. (a) One coat. Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. a) Ground Floor Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary . On Steel Surface With super gloss (hi-gloss) (iv) Two coats Brick edging 75 mm wide with picked jhama bricks laid true to line and level including cutting necessary trench in soil or in hard metalled surface laying the bricks and repacking the trench (on both side of the edging) with posils and ramming the same thoroughly complete as per direction. Brick pavement with 1st class or picked jhama bricks as directed with joints set close in cement mortar (6 :1) and rule\flush pointing with cement mortar (4 : 1). ( Cement - 10.7 kg / Sq.M. ) TOTAL VALUE OF OPEN MARKET SHED TOILET BLOCK (BIG) Earth work in excavation of foundation trenches or drains in all sorts of soil ( including mixed soil but excluding laterite or sand stone ), including removing, spreading or stacking the spoils with in a lead of 75 m. as directed and including trimming the side of trenches, leveling, dressing the bottom, bailing out water etc. as required complete.(a) Depth of excavation not exceeding 1500 mm Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. Cement concrete with graded stone ballast (40 mm. size) excluding shuttering. Nominal mix M-20 cement concrete with graded stone chips (20 mm size) excluding shuttering and reinforcement if any in ground floor & foundation

M2 M2

13

13.1

13.2 13.3 14

MT M2

15

Mtr.

16 16.1 17

Mtr.

17.1 18

%M2

18.1 19

M2 M2

20

20.1 20.2 20.3 21

M2 %M2

22

22.1 8 9 1

91.61

18.768

1,719.34 2 59.2 M3 12.612

1,719.34

746.63 310 4193.28 5707.93 M2 M3 M3 44.79 13,884.90 3.831 16,064.46 7.863 44,881.45

746.63 13,884.90 16,064.46

3 4 5

44,881.45

6.1 6.2 6.3 7

Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (i) Tor steel/Mild steel (a) For works in foundation, basement and upto roof of ground floor / upto 4m. ii) Ground Floor Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) . (a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge. i) Foundation and Plinth ii) Ground Floor Brick work with 1st class bricks in cement mortar (4:1) . a) In Foundation and plinth b) In Ground Floor up to roof 125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in ground floor 25mm. thick damp proof course with cement concrete with stone chips (3:1.5:1) [with graded stone aggregate 10mm nominal size]and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st.coat after 4 to 5 days of cocrete laying and 2nd. coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately). Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide of required to match colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Morter (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sq.m & joint filling using white cement slurry @ 0.20 kg/Sq.m. (a) Area of each tile upto 0.09 sq.m. ii) Coloured decorative (B) Wall with sand cement mortar (1:3) 15mm thick & 2mm thick cement slurry at back side of tiles using cement @ 2.91hg/Sq.m a) Area of each tiles upto 0.09 Sq.m i) Coloured decorative Supplying and laying Polythene Sheet (150gm/sq.m.) over damp proof course or below flooring or roof terracing or in foundation trenches. Supplying fitting and fixing in position approved P.V.C. door frame (matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/- 0.2mm) horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.2 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials taxes and all other incidental charges complete. Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59mm x 30mm section with 2.0mm (+/- 0.2mm) wall thickness, horizontal & vertical section shall be fixed to each other by self tapping screws and one solid polymeric / M.S. galvanised tubular L-shaped brackets 100mm x 200mm in each corner of the shutter frame for placing hinges, polymer based multicavity holoow section of 120 mm x 30 mm with 2.0mm (+/0.2mm) wall thickness will be fitted in the middle as lock rail, reinforced by solid polymer bar of 200mm long at both ends & screws for both sides. The section frame will then be fitted in by PVC panels of size 100mm x 25mm, with wall thickness 1.2mm (+/- 0.2mm) and 2 nos. of 6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials and labour hire of tools and plants and appliencies. Carriage of all materials taxes and all other incidental charges complete.The rate is exclusive of cost of hinges, hasp bolt, tower bolt, door ring etc. Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course i) 20 mm thick with cement mortar(1:6) ii) 15 mm. thick plaster(1:4) iii) 10 mm thick plaster(1:3) Neat cement punning about 1.5 mm. thick in wall, dado, staircase M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.

72732.45

Mt Mt

1.084 78,841.98 78,841.98

7.1 7.2 7.3 8 8.1 8.2 9 10

276.67

M 2 M M2 M2 M2 M2

53.97

14,931.88

14,931.88

5217.45

5.827

30,402.08

30,402.08

11

11.1 11.2

11.3 11.4 11.5 11.6 11.7 11.8 12

M2

M2 M2

13

Mtr.

14

14.1

M2

15

15.1 15.2 15.3 16 17

M2 2 M M2 M2

17.1

Qntl.

18

18.1 19

19.1 20

20.1 21

21.1 22

22.1 22.2 23 24

24.1 25

26

27

27.1 27.2 27.3 28 28.1 29

29.1

M.S. clamp for fixing door and windows frame made of flat bent bar, end bificaled fixed in cement concrete with stone chips (4:2:1) etc all complete a) 40mm x 6mm, 250mm Anodised aluminium barrel/ tower/ socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws. (ix) 150mm long x 10mm dia. bolt. Anodised aluminium Aldrop/Sliding bolts of approved quality manufactgured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (i) 300 mm x 16 mm dia Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws. (v) 125 x 63 x 3.2 mm. Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete. (a) With continuous plate base (hexagonal/round rod) (i)150 mm grip x 12 mm dia Colour washing with any shade with Stainers, as required including cleaning and smoothening surface thoroughly . Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the Engg-in-charge. (a) One coat. Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification.( Two coats.) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary . On Steel Surface With super gloss (hi-gloss) (iv) Two coats (with any shade except white) Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete ( in all floors) i) 3mm thick Supplying fting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straitning if required, fixing lugs in cement concrete ( 4:2:1) with stone chips 19 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hunge shutters and horizotal glazing bars, with or outhout fixed type ventolators ( the extra rate admissible for the openable portion on it.) TOTAL VALUE OF TOILET BLOCK (BIG) GODOWN Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary. Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 150 mm. including watering and ramming etc. layer by layer concrete ( payment to be made on the basis of measurement of finished quantity of work).

Each

Each

Each

Each

Each M2

M2 2 M

M2

M2

M2

9 17 1

91.61

M3

395.806

36,259.79 59.2 M3 259.177

36,259.79

15,343.28 3 Filling in foundation or plinth by Silver sand in layers not exceeding 150 mm. as directed and consolidating same by through saturation with water ramming complete including the cost of supply of sand ( payment to be made on measurement of finished quantity cement concrete with graded Stone Ballast (40 mm. size) excluding shuttering in ground floor and foundation with proportion ( 1:3:6) Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. Nominal mix M-20 cement concrete with graded stone chips (20 mm size) excluding shuttering and reinforcement if any in ground floor. (with Pakur variety) Hire and labour charge for shuttering with centering and necessary staging up to 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs beams columns lintels curved or straight including fitting. Fixing and striking out after completion of works ( up to roof of ground floor) 30 mm. to 37 mm. thick wooden shuttering as per decision and direction of Engineer-in-Charge Reinforcement reinforced concrete work in all sorts of structures including distribution bars, stirrups , binders etc. including supply of roads initial straightening and removal of loose rust ( if necessary) cutting to requisite length , hooking and bending to correct shape, placing in proper position and binding with 60 gauge black annealed wire at very intersection , complete as per drawing and direction For works in foundation basement and up to ground floor 1.25 % of the volume of concrete Brick work with 1st class bricks in cement mortar (6:1) 728.53 M3 562.751

15,343.28

409,980.99 4193.28 310 M3 M2 M3 M2 21.635 90,721.61 273.82 84,883.58 5707.93 143.509 819,139.33 276.67 655.15

409,980.99 90,721.61

4 5

84,883.58

819,139.33

181,260.35 72732.45 MT 17.248

181,260.35

1,254,489.30

1,254,489.30

9.1 9.2 9.3 10

11.1 11.2 12 13 14

15

(a) In foundation & plinth (b) In superstructure. Up to 4.000m. (c ) In superstructure. Above 4.000m. Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating, nosing and drip course where necessary (ground floor). With 6:1 cement mortar a. 20 mm. thick plaster , In ground floor With 6:1 cement mortar 15 mm. thick plaster. In ground floor Neat cement punning Supplying and laying Polythene Sheet (150gm./sq.m) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches Artificial stone in floor, dado, staircase etc. with cement Concrete (4:2:1) with stone chips ,laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (2:1) including smooth finishing and rounding off corners and including application of cement slurry before flooring woks, using cement @ 1.75 Kg./sq.m. all complete including all materials and labour. In ground floor 35mm. thick.,3 mm. thick topping with ordinary cement

4897.2

M M3 3 M

129.92

636,249.12

636,249.12

M M2 M2 M2 M2

16

17

18

19

20

20.1 20.2 21 22

23 24

M.S. structural works in roof trusses with Hollow Section (TATA make) conforming to IS: 816-1956 & IS:9595 connected to one another with bracket,guscet,cleats as per design, direction of Engineer-In-Charge complete including cutting to requisite size,fabrication with necessary metal are welding conforming to IS: 816-1956 & IS: 9595 using electrodes of approved make and brand conforming to IS: 814-1957, haulage,hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charges of all tools and plants and labour required for the work including all incidental charges such as electricity charges ,labour insurance charges etc. For trusses spanning above 20 m. and upto 30.0m. Supplying corrugated Zinc Alluminium alloy coloured coated steel sheet ( 0.45 mm thk.) on roof (excluding supporting frame work fitted, fixed with self tapping pressure fastning bolt of 12-24 mm dia with necessary EPDM and colour coated steel washer with 150 mm end laping and one corrugation on side laping complete with all incidental work. (The work is to be carried out as per literature as specification laid down in the "Durashine TM" products and also as per the direction of Engineer-in-charge. Supplying, Fitting Corrugated Zinc Alluminium alloy coloured sheet ridging 225mm. lap each way and fitted with necessary bolts ,screws, washers etc. complete. With 0.45 mm sheet with lap of 30 cm.each way.. Supplying,fitting and fixing steel rolling shutter profile type with 18 B.G. of approved type, steel latche section 75mm wide fitted with coil wire spring to necessitate the fitting of required No. of C.I. pulleys on heavy type solid drawn seamless steel tube complete with locking arrangement both inside and outside specially built up side guide channels including providing a hood for the steel rolling shutter in the room, painting two cats of approved aluminum paint over a coat of red lead primer complete Applying Exterior/Interior grade Acrylic primer of approved quality and brand on plasterd or concrete surface oild or new surface to receive decorative texture or smooth finish acrylic exterior emultion paint including scraping the same thoroughly (plastered or concrete surface) as per manufacturers specification. In ground floor. Two coats Exterior grade Interior Grade Applying decorative cement based paint of approved quality after preparing the surface including scraping the same . Protective and decorative acrylic exterior emulsion paint of approved quality including cost of materials labour scaffolding all intidental charges. Painting with ready mixed red led paint of approved make and brand Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface of necessary materials . (iv) 2 coat on steel or other metal surface with super gloss. Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed. 25 mm X 750 mm long (A) Galvanised iron sheets valley gutter with perimeter not lass than 750 mm. with 225 mm. lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. TOTAL VALUE OF CONSTRUCTION OF GODOWN

Mt.

M2

Mtr.

M2 M3 M2 M
2

M2

24.1 25

M2 nos.

25.1 26

26.1 17

Mtr.

TOTAL VALUE OF LAND DEVELOPMENT TOTAL VALUE OF CONSTRUCTION OF BOUNDARY WALL TOTAL VALUE OF SINGLE SHOP CUM GODOWN TOTAL VALUE OF 200 MT CAPACITY AUCTION HALL TOTAL VALUE OF ADMINISTRATIVE BUILDING TOTAL VALUE OF KRISHAN SAHAYAK KENDRA TOTAL VALUE OF OPEN MARKET SHED TOTAL VALUE OF TOILET BLOCK (BIG) TOTAL VALUE OF CONSTRUCTION OF GODOWN

1,320,999.55 1,969,136.18 988,992.23 2,120,230.09 2,054,662.97 2,778,213.90 1,222,793.51 201,472.71 3,528,327.34

Total value of work done or suppliers made to date ....... (A) Deduct Value of Work or supplies shown on previous bill ......

Net Value of work or supplies since previous bill ....... (B) Figure (F) in words, Rupees .......... .

II Certificates and Signatures The measurements were made by .. on and are recorded at page ... of Measurement Book No. .. No. Adv Payment has been made previously without detailed measurements.

(Rank) Sub-divisional Officer, Dated Signature of officer .. Sub-Division

Preparing the bill .... Division . Dated Signature of Contractor Dated Signature of Officer ...

Authorizing payment (Rank) ...

Вам также может понравиться