Heat transfer rate for Limpet coil type jacket Description Name Pressure Temperature Viscosity density Mass

flow rate P T,t m Nomenclature Jacket fluid properties HW 3.5 343 0.00108 985 11077.764 3.08 specific heat capacity Half-pipe diameter De (Equivalent diameter) thermal conductivity Pitch Total length of limpet coil (vertical) Diameter of limpet coil (helix) Agitator diameter Agitator width Agitator rps Daimeter of tank Agitator index Metal thermalconductivity Thickness of shell Ri (shell scale resistance) Ro (jacket scale resistance) Jacket side heat transfer coefficient Reactor side heat transfer coefficient Rd = Ri+Ro (dirt factor) Rw (Wall resistance) 1/Uo Uo 0.00742 134.682 W/ m2 K 174.305 k Dv Cp D De k Dg Dp Dc L W 4186 0.142 0.223142857 0.59 0.05 3.06 1256 J/kg K m m 0.4 W/m K m m 2.10 m 1.1 m 0.085 m 1.6 1.95 m 0.67 15 W/m K 0.008 m 0.0002 m2 K/W 0.0001 m2 K/W m2 K/W 657,157.66 m2 K/W 0.0003 m2 K/W 0.000533333 m2 K/W 1/U U Q 0.00711 140.74 W/m2 k 1,007.516 W 1.0075 KW With agitator dimension value of Q Input Shell side fluid Reaction mixture barg 305 K 0.00044 mN s/m2 1326 kg/m3 2840 Unit LMTD T1(jacket) in T2(jacket) out t1(Vessel) initial t2(Vessel) final dt1 dt2 LMTD No. of Limpet coils Length of channel Area Q 343 K 341 K 305 K 331 K 38.00 K 10.00 K 20.974 K 15.938 97.647 m 0.341 m2 964.141 W 0.964 KW

Vessel side ho ( other equations) heat transfer co-efficient ho hb hb For square tank ho 753798.4921 m2 k / W 3113.553877 m2 k / W 2804.603697 m2 k / W 4175.429017 m2 k / W