Вы находитесь на странице: 1из 2

Jetta Construction Sdn Bhd *Beam Type:-

Block 19 - Training SQN Classroom 1 Normal Beam


Element : Roof Beam - Conc & Fwk 2 Normal Beam At Edge (for fwk)
3 Sloping Beam
4 Sloping Beam At Edge (for fwk)
5 Upstand Beam
6 Curved-on-plan beam

Grid *Beam Beam size Slab Nos Nos Nos 1. BEAM ddt fr wall
Line Note/ Type (m) Thick Length of of of Conc Formwork SOFFIT OF ext int
BEAM REF (m3) (m2) BEAM (M2)
W x T (m) (m) Bm Flr Blk 1 2 5
NO. Level SAWN
1 Horizontal A & F/1-8 RB2 2 0.200 0.600 3.00 7 2 1 5.040 58.800 8.40
2 B & E/1-8 RB4 2 0.200 0.450 3.20 7 2 1 4.030 49.280 8.96 24.64
3 C & D1/4-5 RB6 2 0.200 0.450 3.40 1 2 1 0.610 7.480 1.36
4 C-D/4-5 RB8 5 0.150 0.600 3.40 1 4 1 24.480 2.04

1 Vertical 1 & 8/A-F RB1 2 0.300 0.600 14.40 1 2 1 5.180 43.200 8.64 21.60
2 less column 2 0.200 0.300 1.00 -4 2 1 -0.480 -6.400 -1.60 -3.20
3 4 & 5/B-C1 RB3 2 0.200 0.600 5.10 1 2 1 1.220 14.280 2.04 7.14
4 4 & 5/C1-D1 DITTO 2 0.200 0.600 3.00 1 2 1 0.720 8.400 1.20 4.20
5 4 & 5/D1-E DITTO 2 0.200 0.600 3.00 1 2 1 0.720 8.400 1.20 4.20

TOTAL 40 16 17.04 0.00 183.44 24.48 32.24 43.04 15.54


m2 m2
TOTAL OF CONCRETE = 17.04 M3

FWK TO SIDES OF BEAM = 207.92 M2

FWK TO SOFFIT OF BEAM = 30.20 M2

ROOF BEAM ABOVE VERANDAH


ANY ?

09/25/2009 21:45:43 1/2 22558050.xls Roof


Level Grid *Beam Beam size Slab Nos Nos Nos
Line Note/ Type (m) Thick Length of of of Girth FINISHES (F5) TO EXPOSED EO TO FORM
BEAM REF SIDES & SOFFIT WEATHERPF THROAT
NO. W x T ( mm ) (m) Bm Flr Blk (m)
0.3
1 A & F/1-8 RB2 2 0.200 0.600 3.00 7 2 1 0.730 30.660 8.40
2 1&8/A-B & E-F RB1 2 0.300 0.600 1.00 4 2 1 0.730 5.840 2.40

0.23
0.2

230 + 200 + 300 = 730mm


TOTAL 36.50 m2 ### 10.80
m

09/25/2009 21:45:43 2/2 22558050.xls Roof