Jan 24, 2014 / DATA VISION CONS.ENG

Project documentation
created with

SIMARIS design
Version: 7.0.0 (12-03-2013)
Subrevision: 2620
SIEMENS AG 2014. All rights reserved.
http://www.siemens.com/simaris

Master data
Project name:

new

Project description:

new

Editor:

DATA VISION CONS.ENG

Planning office:
Created at:

Friday, January 24, 2014

Changed at:

Friday, January 24, 2014

Customer data
City:
Customer:

Comment:

Page 1/11

new
Jan 24, 2014 / DATA VISION CONS.ENG

Network parameters:
General
Standard
Attitude of Site

IEC
< 1000 m
Medium Voltage

Rated voltage
Ambient temperature
Voltage factor c max
Voltage factor c min
Max./Min short-circuit power
Neutral System
Relation R1/X1 min

20 kV
40 C
1.1
1
250 / 100 MVA
Low-resistance
0.2

Low Voltage
Rated voltage
System configuration
Frequency
Tolerable touch voltage
Ambient temperature of devices
Voltage factor c max
Voltage factor c min
Base point of voltage drop calculation
Relative operating voltage at reference point
Max. permissible voltage drop in network

400 V
50 Hz
50 V
45 C
1.1
0.95
Transformer-primary terminals
100 %
14 %

Page 2/11

new
Jan 24, 2014 / DATA VISION CONS.ENG

Defined network modes for calculation and dimensioning:

Page 3/11

new
Jan 24, 2014 / DATA VISION CONS.ENG

List of devices:
Sources of feeding:

Page 4/11

new
Jan 24, 2014 / DATA VISION CONS.ENG

Switches/Fuses:

Page 5/11

new
Jan 24, 2014 / DATA VISION CONS.ENG

Connections and line distribution:

Page 6/11

new
Jan 24, 2014 / DATA VISION CONS.ENG

Load:

Page 7/11

new
Jan 24, 2014 / DATA VISION CONS.ENG

Personal protection against electric shock


All circuits of the project have a permissable break time ta-req > ta-cur and therefor fulfill the requirements for Personal protection
against electric shock.

Disclaimer:
Dimensioned protection devices inside tap-off units of busbar trunking systems may not correspond to the actual available
devices for those components. Please verify the dimensioning results in the device lists and correct them accordingly.

Page 8/11

new
Jan 24, 2014 / DATA VISION CONS.ENG

Symbols legend:
Symbol [Unit]

Description

ai
cos
ftot

Load factor
Power factor
Derating factor

Ia/In

Inrush current relation

Ib [A] Iz [A]

Operating current / allowed load capacity

Icu(fuse) [kA]
Icu [kA]
Icn [kA]
Icu/Icn [kA] required

Rated ultimate short-circuit breaking capacity - fuse


Rated ultimate short-circuit breaking capacity according to IEC 60947-2
Rated short-circuit breaking capacity according to IEC 60898-1
the required breaking capacity of the protection device at installation location

Icw 1s [kA]

Rated short-time withstand current 1s

In [mA]

Residual current - RCD

Ik1max

Maximum single phase short-circuit current

Ik1min

Minimum single phase short-circuit current

Ik3max

Maximum three phase short-circuit current

Ik3min

Minimum three phase short-circuit current

Ik1D [kA]

single pole uninterrupted short-circuit current

Ik3D [kA]

three pole uninterrupted short-circuit current

Ikmax/Ikmin

Relation of maximum and minimum short-circuit current

Ikre

Short-circuit current recovery factor

In [A]

Nominal current

P0 [kW]

No-load losses

Pk [kW]

Short-circuit losses

Pmech [kW]

mechan. Power

Pn [kW]

Active power

R0 N [m]

Zero phase-sequence resistance phase-neutral conductor

R0 PE(N) [m]

Zero phase-sequence resistance phase-PE(N) conductor

R0/R1

Resistance relation positive / zero phase-sequence system

r1 [%]

Relative value of positive phase-sequence resistance

R1 [m]

Positive phase-sequence resistance

Sn [kVA]

Nominal apparent power

ukr [%]

Short-circuit voltage

Un [V]

Nominal voltage

Uprim [kV]

Primary voltage

Usec [V]

Secondary voltage

X0 N [m]

Zero phase-sequence reactance phase-neutral conductor

X0 PE(N) [m]

Zero phase-sequence reactance phase-PE(N) conductor

X0/X1

Reactance relation positive / zero phase-sequence system

X1 [m]

Positive phase-sequence reactance

xd'' [%]

Subtransient reactance

Z1 max

Maximum impedance in positive phase-sequence system

Z1 min

Minimum impedance in positive phase-sequence system

Zs

Faulted circuit impedance

Zs max

Maximum faulted circuit impedance

Zs min

Minimum faulted circuit impedance


Relative nominal voltage / voltage drop between beginning and end of a section / cumulated voltage drop
from the transformer primary/ secondary clamps to the specified point
Conductor temperature of MV cable / Conductor temperature of LV cable
for voltage drop / on beginning of short circuit / for disconnection

u [%] / u [%] / u [%]


u [C] / Ikmax [C] / Ikmin
[C]

Page 9/11

new
Jan 24, 2014 / DATA VISION CONS.ENG

Efficiency

[]

Phase angle

1 min/max []

Phase angle at Ik1 min/max

3 min/max []

Phase angle at Ik3 min/max

Page 10/11

new
Jan 24, 2014 / DATA VISION CONS.ENG

Standards for computation:


Title

IEC

HD

Low-voltage electrical installations *

60364-16

384

Short-circuit currents in three-phase a.c. systems Calculation of currents


Short-circuit currents calculation of effects
Definitions and calculation methods
Low-voltage switchgear and controlgear Circuit-breakers

60909

60909

0102

60865

60865

0103

60947-2

60947-2

0660 101

Low-voltage switchgear and controlgear assemblies


A method of temperature-rise assessment by extrapolation for partially typetested assemblies (PTTA) of low-voltage switchgear and controlgear
Electrical installations of buildings Part 5-52: Selection and erection of
electrical equipment Wiring systems
Electrical accessories Circuit-breakers for overcurrent protection for
household and similar installations Circuit-breakers for a.c. operation
High-voltage switchgear and controlgear Alternating Current switch-fuse
combinations
Electrical installations of buildings Selection and erection of electrical
equipment Isolation, switching and control
Low-voltage electrical installations Protection for safety Protection against
voltage disturbances and electromagnetic disturbances
Protection against lightning Part 14
Low-voltage surge protective devices - Surge protective devices connected to
low-voltage power systems; Requirements and tests
Tests for electric cables under fire conditions Circuit integrity

60439

60439-15

0660 500505

Fire behaviour of building materials and building components Part 12:


Circuit integrity maintenance of electric cable systems, requirements and
testing
Electrical equipment of electric road vehicles - Electric vehicles conductive
charging system

EN

DIN VDE
0100 100...710

60890+C

528 S2

0660 507

60364-5-52

384

0298 4

60898-1

60898-1

0641 11

62271

62271

0671 105

60364-5-53
60364-4-44

60364-5534
60364-4443

0100-534
0100-443

62305-14

0185 14

61643-11

0675-6-11

60331-11,
21

50200

61851

61851

0472-814
0482-200
4102-12 : 1998-11

*) Special national conditions and deviations from IEC 60364-4-41: 2005 are not implemented and need to be considered!

Page 11/11