Вы находитесь на странице: 1из 4

Sr. No.

Page Location

Details of change Impact area Permited the use of room temperature design values from sec. II, parD, to be used for dsign at colder temperature. Design/FEA 80 3.16 in last two columns of the top row, the second"</=" in each equationcorrected by FEA 146 Table 3-F.3 errata to read "<" Added requirement that joint alignment must be considered when vessel is operating at a temperature where time-dependant properties govern the allowable stress. FEA

151 4.1.1.3

4 5 6 7

The defination of the term "Design Thickness" is modified by adding corrosion allowance. use of external standards for Wind Loads & Earthquakes s allowed by code. 153 4.1.5.3 Transportation load added to dead weight of 156 Table 4.1.1 vessal. 157 Table 4.1.2 Added 0.6 before W 152 4.1.5.1

Design & FEA Design /FEA Design,FEA Design, FEA

8 191

4.3.9.2

equation 4.3.29 revised

9 200 10 211

11 12 536

13 538

In the equation beginning with Ncq, in the second column under, "Stress Resultant Table 4.3.1 Calculation", +Qc corrected to -Qc. Fig. 4.3.7 Figures corrected for variable referance 2) In equations beginning with 'V' under "For 0.25<Xh2.0", Xh^2Xh, corrrecteds by errata to read "Xg^2Xh" use of external standards for Wind Loads & 5.1.3.2 Earthquakes s allowed by code. 1) modified primary local membrane & primery local membrane plus bending stress limit in para 5.2.2.4 Added variable SPL. Modify fig. 5.1 5.2.2.4 to reflect new stress limit for PL & PL = PB stress step 5 revised categories.

Design, FEA Design Cal. & FEA of Dampners may affect FEA/Cal fea & calculations Design /FEA

FEA assesment procedure change

14 544 15 549 16 550

5.5.1.7 5.5.4.2 5.5.5.2

For fatigue analysis effect of Joint alignment & weld peaking in shells & heads to be considered FEA-Fatigue Step 5 revised for Effective Strain Range FEA FEA Rk > 0' corrected to 'Rk 0' & '2Sy,k'

17 553 18 554 19 20 21 22 563 564 564 565

23 608 24 618 25 26

revised to exclude all thermal stresses for simplified elastic - plastic P+Q check Revised to include all thernmal membrane 5.5.6.3 ratcheting criteria. 1) Added Load due to transportation to Table Table 5.2 5.2 Table 5.3 Added 0.6 before W Table 5.4 Revised Globle criteria conditions Table 5.5 Revised Globle criteria conditions in equation 5-E.7 exponent changed from 0.5 5-E.6.1 to 2 in equation 5-E.8 exponent changed from 0.5 Table 5-E.8 to 2 5.5.6.2

FEA FEA FEA FEA FEA FEA FEA FEA

Action to be taken

Coefficent for fatigue curve 110.2.1-series 3XX High Alloy Steels, NickelChromium-Iron alloy, Nickle-Iron-Chromium Alloy & Nickel-Copper Alloy For temperature not exceeding 427C

need to check if the case is simulated in FEA

Change design thickness +corrosion allowance Can use other ref standards for wind load & Earthquakes calculations. Need to re-run the FEA Need to re-run the FEA Equation for "drilled holes not penetrating through the vessel wall" changed. Need to redesign/ rerun fea. 1) Tresca based equations changed to average circumferential stress equations. 2) sign added to correct bending moment equations

Need to change design Cal. & Fea of DPD/PPD for Cylindrical to conical shell transation junctions with a Knuckle Need to check why sheare force is not considered in this edition.

need to update calculations Can use other ref standards for wind load & Earthquakes calculations.

need to update FEA as per new assesment procrdure.

FEA to reruen for fatigue analysis Fatigue assesment procedure changed to be considered. Fatigue assesment of weld changed.

To be considered during Analysis To be considered during Analysis Need to re-run the FEA Need to re-run the FEA Need to revise Need to revise