Вы находитесь на странице: 1из 1

SPEC 4325

March, 2012

FREP

FR-EPR/CPE, Control, Shielded


600 V, UL Type TC-ER1, Overall ShieldedE-2 Color Code
Product Construction:
Conductor:

16 AWG thru 10 AWG fully annealed stranded


tinned copper per ASTM B33
Class B stranding per ASTM B8

Insulation:

Flame-Retardant Ethylene Propylene Rubber


(FR-EPR) Type II
Color-coded per ICEA Method 1, Table E-2
(does not include white or green)

Shield:

Overall shielded multi-conductor cable


Overall shield is Flexfoil aluminum/polymer in
contact with stranded tinned copper drain wire

Jacket:

Lead-free, flame-retardant thermoplastic


Chlorinated Polyethylene (CPE)

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. COND.
THICKNESS
THICKNESS
CABLE
O.D.
OF
SIZE COND.
LBS/
LBS/
COND. (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

OVERALL SHIELDED MULTI-CONDUCTORS


16 AWG CONDUCTORS

Print

GENERAL CABLE (PLANT OF MFG) SHIELDED


FREP XX/C XXAWG EPR/CPE (UL) TYPE TC-ER
XHHW-2 CDRS 90C WET OR DRY 600 V DIR
BUR SUN RES DAY/MONTH/YEAR OF MFG
SEQUENTIAL FOOTAGE MARK

280470
280490

2
3

Applications:

In free air, raceway and direct burial


In wet or dry locations
Permitted for Exposed Run (ER) use in
accordance with NEC for 3 or more conductors
A
 pproved for direct burial
Class I, Division 2 industrial hazardous locations
per NEC

280980*
354800*
305300*
354810*
354820*
367120*
354830*
305360*
367130*
367140*
367150*

2
3
4
5
7
9
12
19
25
30
37

Features:

Rated at 90C wet or dry


Ripcord applied to all cables with jacket thickness
of 60 mils or less
Excellent physical, thermal and electrical
properties
Sunlight- and weather-resistant
Excellent moisture resistance
Excellent resistance to compression cuts and heat
deformation
Low coefficient of friction for easy pulling
Excellent flame resistanceburns to ash;
does not exhibit thermoplastic drip
Excellent low temperature cold bend
characteristics
Meets cold bend test at -40C
Meets the crush and impact requirements of
Type MC cable for 3 conductors or more

Compliances:

Industry Compliances:
UL 44 Type XHHW-2
UL 1277 Type TC-ER for 3 or more conductors,
UL File # E57179
UL 1581
ICEA S-73-532/NEMA WC57
Flame Test Compliances:
UL 1581/UL 2556 VW-1
UL 1685 Vertical Flame Test
IEEE 383
IEEE 1202
CSA FT4
ICEA T-29-520
Other Compliances:
EPA 40 CFR, Part 261 for leachable lead
content per TCLP
OSHA Acceptable

Packaging:

Material cut to length and shipped on


non-returnable wood reels

Phone: 888-593-3355
www.generalcable.com

7/.0192 0.025 0.64 0.045 1.14 0.320 8.13


7/.0192 0.025 0.64 0.045 1.14 0.335 8.51

19
27

28
40

52
66

77
98

43
63
82
101
140
180
238
375
484
579
696

74
95
118
142
176
243
304
471
627
750
878

110
141
176
211
262
362
452
701
933
1116
1307

OVERALL SHIELDED MULTI-CONDUCTORS


14 AWG CONDUCTORS

Options:

2 kV version
Bare copper conductor
Class C stranding
E-1 Color Code
Unshielded multi-conductors
Flame-Retardant Cross-linked Polyethene
(FR-XLPE) insulation
Thermoplastic Low-Smoke, Zero-Halogen
(LSZH) jacket
Other constructions available upon request

16
16

14
14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

0.375
0.395
0.430
0.470
0.510
0.625
0.705
0.820
0.940
1.035
1.115

9.53 29
10.03 42
10.92 55
11.94 68
12.95 94
15.88 121
17.91 160
20.83 252
25.53 325
26.29 389
28.32 468

OVERALL SHIELDED MULTI-CONDUCTORS


12 AWG CONDUCTORS
367160*
367170*
326650*
367180*
326660*
367190*
326640*
326670*
367200*
367210*
367220*

2
3
4
5
7
9
12
19
25
30
37

12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

0.415
0.440
0.480
0.525
0.600
0.700
0.770
0.945
1.100
1.155
1.245

10.45 43
11.18 66
12.19 87
13.34 108
15.24 151
17.78 193
19.56 249
24.00 393
27.94 517
29.80 620
31.62 764

64
97 144
98 127 189
129 160 238
162 194 289
225 271 403
287 340 506
371 431 641
585 691 1028
769 857 1275
923 1005 1496
1137 1243 1850

OVERALL SHIELDED MULTI-CONDUCTORS


10 AWG CONDUCTORS
311900*
367230*
311910*
367240*
367250*
367260*
367270*

2
3
4
5
7
9
12

10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.52
1.52
1.52
1.52
2.03

0.460
0.490
0.565
0.620
0.675
0.765
0.910

11.68
12.45
14.35
15.75
17.15
19.43
23.11

68
103
136
170
237
298
404

101
155
202
253
353
443
601

Dimensions and weights are nominal; subject to industry tolerances.


* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.
Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

131
175
237
287
384
467
654

195
260
353
427
571
695
973