Вы находитесь на странице: 1из 1

Soft Solution Machine Foundation

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

Equipment Base

A B C D E F G H I J K L M N O P Q Addendum to STQ 1503 ISBN 81-901030-7-5 NavigationIrrigation Pump Shed- Pump foundation Machine Foundation - Design - Natural frequency of foundation soil system & amplitude check References Barkan's formula to determine value of Az Cycles (f)/m v/s amplitude curves RPM in cycles amplitude in mm vn Foundation parameters & 2.5 mm for 2900 rpm 2900 Az Length Breadth Depth Concrete Foundation weight Machine m' EUCS Natural Frequency Operating Frequency OF/NF Soil density Amplitude vn vm L B D Density Concrete Soil weight Mass(Total) cu cu*A h g Po Az m m m kg/m^3 kg kg kg kg kg/m^2 (cu*A/m)^1/2 Manfacturer's datasheet # kg/cm^3 kgmf mm Method 1.6 1.6 0.35 2500 2240 358.4 990 365.79 7680 19661 7.331362139 2.83 0.386 1.6 2611.1 1.560622 1 m^3 0.896 Pump 395 by equation 1.0855 27788 8.715972306 2.83 0.3247 1.6 2611.1 1.050376 2 [cu=1.13-E/(1m ^2) /a^.5] Pump 395 Reference Cycles(f )/m v/s amplitude curves mm cu' determined by both methods Method Vessel 100 Permissible amplitude 2.5 By' Elastic-Area' equation 1 Frame 100 Since' foundation soil system' amplitude is within limits, the foundation is safe in vibration By 'soil bearing' table consideration 2 Sand Silt General principle [cu=1.13-E/(1-m ^2) /a^.5] Soil E m m Coefficient A Cu Wherever possible, the operating frequency should be Kg/cm^2 poisson's ratio poisson's ratio in equation cm^2 Kg/cm^2 lower than the natural frequency of the foundation soil 2000 0.35 0.4 1.13 25600 1.085484 system & preferably within ratio 0.5 L Foundation length m otherwise it should be more than 2 B Foundation breadth m In this case the ratio is 0.386 0.324691 D Foundation depth m cu Soil elastic uniform compression coefficient for 10 m^2 foundation area 3 to 5 Kg/cm^2 Comparison A Foundation area m^2 Frequency ratio Amplitude v n Natural frequency of foundation soil system vibration Permisible Permisible v m Operating frequency of machine vibration 0.5 2.5 h Operating frequency of machine vibration/Natural frequency of foundation soil system vibration Provided Provided g Soil density kg/cm^3 0.386012851 1.5606 1.050376 Po Exciting force produced vertically on machine kgmf Resonance shall not occur Az Amplitude mm Design satisfies both conditions ` m Poisson's ratio E Young's modulus of elasticity of foundation soil Kg/cm^2 m Combined mass of soil, foundation & machine Kg

ApplicationDeveloper PEng Suraj

208399534.xls.ms_office

8:13 PM2/2/2014

Вам также может понравиться