Instruction Manual for DHT-U

2.2.2 Menu Screen 2 Blade Number

Instruction Manual for DHT-U

1.
Voltage ratio A1 A2 Unit Set Switch (Altit/Temp/Speed) Alarm for Voltage/RSSI/LipoVoltage/Altitude

Introduction

1.1 Compatibility: Compatibility

Mode of DHT-U

V8 _Mode

Non-telemetry receivers (V8R7-SP, V8FR-II/V8FR-HV, V8R7-II/V8R7-HV, V8R4-II)

D_Mode

Telemetry receivers (D8R-II plus/D8R, D8R-XP/D8RSP, D6FR, D4R-II/D4FR)

1.2 Features:
Alarm RSSI Than Value

FrSky default values for RSSI, users can change according to their requirements: 1 2 45 42

1) All-in-one combination of telemetry module, inbuilt display and alarm threshold settings

2) DHT-U can be clamped to the transmitter handle/antenna

3) Show in-flight data via in-built display

4) Capable of setting failsafe during flight


Capable of selecting 8 data to show on the first two data screens, 4 data for each.

Button A

Button B

Button A

2.2.3 Menu Screen 3

5) Firmware upgradable

1.3 Specification:
2.2.4 Menu Screen 4

Operating Voltage Range: 6.0V-13.0V

Operating Current:

50mA

Output Power:

60mW

Resolution:

3072 (>11bit)

Press button B to set failsafe during flight, or others to skip. 2.3 Data Screen FrSky sensor hub, sensors and D8R, D8R-II plus, D8R-XP, D4R-II telemetry receivers are required if information collecting and processing, model monitoring and data feedback are required. 2.3.1 Data Screen 1
GMT(H/M/S) Fuel Level

2.

Screen structures

2.1 Main Screen

FrSky Logo

Data Screen

Menu Screen

Module ID

Version

Volt 1 Ampere

Temp 1 mAH Rx RSSI & Tx RSSI

2.2 Menu Screen

2.2.1 Menu Screen 1

V8_Mode/D_Mode

Bind/Norma l/Range Check

2.3.2 Data Screen 2


GMT(H/M/S) Fuel Level

Setting

Failsafe

Volt 2 Temp 2 Altitude RPM Rx RSSI & Tx RSSI Press Button A of DHT-U to change between absolute altitude and relative altitude.

Note: When V8_Mode is selected, users will have no access to Setting page or Failsafe page.

Instruction Manual for DHT-U


3.3 Range Check

Instruction Manual for DHT-U

2.3.3 Data Screen 3

Acceleration X/Y/Z Longitude

Latitude

Home

A pre-flight range check should be done before each flying session. Reflections from nearby metal fences, concrete buildings or trees can cause loss of signal both during the range check and during flight.

Speed

Distance

The following steps are to be followed to perform the range check of the model before flight:
1) Place the model at least 60cm (two feet) above non-metal contaminated ground (e.g. on a wooden bench). 2) The receivers antennas should be separated in the model and not touch the ground. Place the module antenna in a vertical position. 3) Turn the transmitter on and enter MENU page, select R-CK, connect battery to the receiver. The effective distance will be decreased to 1/30 of full range. 4) Walk away from the model while simultaneously operating the controls on the transmitter, confirming that all controls operate normally to a distance of 1/30 of the full range.

Press Button Home to know the distance away from the place.

2.3.4 Data Screen 4

Voltage display from FLVS-01(12S MAX)

3.4

Signal Loss Indicator and Failsafe Setting

NOTE:

1, Roll the 3-way rocker switch up and down to switch among data screens.

In some special circumstances, such as strong interference, the signal may be lost. When signal is lost in a short period, the receiver continues to try to search for the transmitter, at the same time it keeps the last command from the transmitter, until a new command is received.
Failsafe is a useful feature in which all controls move to a present position whenever the control signal is lost for a period of time.

2, Press both two buttons on top of DHT-U at the same time for 0.5 second to switch from data screen back to main screen.

Follow the steps below to set failsafe before flight: 1) Bind the receiver first and turn on both transmitter and receiver; 2) Set all transmitter controls to the desired failsafe position;

3.

Set Up

3.1 Installation Process

With newest version, just plug in to the module socket via provided female connecter. For old version you should:

1) Open the transmitter and find out the battery power supply line, GND and PPM signal line.

2) Solder the battery power supply line, GND and PPM signal line to corresponding wires of DHT-U (REDV+; BLACKGND; BROWNPPM).

3) Press briefly the F/S button of the receiver (less than 1 second), the transmitter module will make a long beep (for D8R only) or the GREEN LED of the receiver will flash twice, indicating the failsafe position has been set in the receiver. To disable the failsafe function, re-bind the receiver. Follow the steps below to set failsafe during flight: 1) Bind the receiver first and turn on both transmitter and receiver; 2) Enter MENU page, select F/S to enter failsafe sub-page, press Button B to set failsafe at the desired failsafe position during flight.

3) Clamp DHT-U to the transmitters handle or antenna base by provided clamp and screw.

4) Connect the module antenna to DHT-U.

3.2 Bind Procedure

1) Ascertain that the transmitter is in PPM mode. Turn the transmitter off.

2) Turn the transmitter on and enter MENU page, select V8_Mode or D_Mode to work with corresponding receiver you are using (see compatibility chart above). Select Bind.

ATTENTION
Compatibility with V series Version 2.0 Version 2.3 YES NO Electric current accuracy 1A 0.1A Menu Screen 3 YES NO

3) Connect battery to the receiver while holding F/S button on the receiver. The RED LED on the receiver will flash, indicating the binding process is completed. Turn off the transmitter and receiver.

4) Turn the transmitter on and enter MENU page, select Normal. Re-connect battery to the receiver. The RED SOLID LED on the receiver will indicate receiver is receiving commands from the transmitter.

After above steps are completed, both the transmitter and receiver are ready to be used. The bind procedure will not have to be repeated unless one of the two is replaced.