EI Series Bimetal Thermometers

FEATURES 1% full span accuracy ASME B40.200 (ASME B40.3 Grade A) Maximum ambient temp. is 200F (94C) Hermetically sealed case to prevent entry of moisture, interior corrosion and coil freeze-up. External adjustment permits zero reset from outside the case. Maxivison dial allows readability from any angle without parallax error. Silicone coil dampening (up to 400F) provides vibration dampening and improves response time. All-welded stainless steel construction Heavy-Duty glass lens Protection IP 65 Five year limited warranty
Options:

SPECIFICATIONS
Ashcroft Series: Dial Sizes: Stem Length: Case & Stem: Stem Dia: Window: Dial: Pointer: Connection: Connection Location: Ranges: EI 2, 3, 5 21224 (1) 304 stainless steel, hermetically sealed .250 Heavy-duty glass, plastic or shatterproof glass optional Maxivision, black figures on white background Black Plain, pointed plain, 14 NPT, 12 NPT, 1 2 NPT union Everyangle, Lower, Rear -80/120F 200/1000F -50/50C 100/500C Code Description C4 Individual calibration cert. XCS Dual scale(2) XDM Dial marking XNH Stainless steel tag XNN Paper tag XPD Plastic window XSG Shatter proof glass X3B 38 stem dia. with 12 NPT X02 14 NPT when 12 NPT is standard XS1 Silicone free

(1) Special or longer length available, consult factory (2) Dual scale avilable with 3 and 5 case only (3) Only available on rear connection

Thermowells must be used on all pressure or velocity applications, to protect the stem of thermometer from corrosion and physical damage, and to facilitate removal of the thermometer without disturbing the process. Maximum ambient temperature is 200F (95C).

HOW TO ORDER
30 Dial Size: 3 Code 30 Case Style: EI Stem Connection: 12 NPT Code 60 Stem Location: Rear Code R Stem Length: 4 Code 040 Range: Code 0/250F Options: Stainless steel tag EI 60 R 040 0/250F XNH

BULLETIN BM-EI

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft Inc. 2013 10/2013

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281 Fax: 203-385-0408 email: info@ashcroft.com www.ashcroft.com

EI Series Bimetal Thermometers


EI Series selection table
Case Size Stem Stem Lengths Available S Code Length Code (inches) R 2 2 4 6 9 12 15 18 24
1

EI Series dual scale ranges


Temperature Range F* C / Div. Fig. / Div. Fig. Fahrenheit Inter. Celsius Inter. 80/120 2 20 50/50 1 10 20/120 20/120 2 20 30/130 1 10 0/50 1 5 0/200 0/100 1 10 20 2 0/250 10/150 2 20 50 50/300 0/200 50/400 0/300 50/550 5 50 50/450** 5 50 200/700 100/500** 100/800 200/1000** 10 100 Dual scales are available in 3 and 5 dial sizes in the following ranges: Inner 80/120F 40/120F 40/160F 20/120F 0/200F 0/250F 30/130F 50/300F 50/400F 50/550F 100/800F
Weight in ounces(3)

Dial Code Style Conn. Code Location Code 40 Plain Pointed 50 Rear 2 20 1 4 NPT 60 1 1 2 2 NPT Union 42 Everyangle Union 1 60 NPT 60 30 3 30 Rear 3 EI 122 NPT Rear 1 Lower 2 NPT 60 Lower 1 12 NPT 2 NPT 42 42 Everyangle Union Everyangle Union 1 12 NPT 5 50 60 2 Rear 1 2 NPT 60 Lower

Outer and and and and and 60/50C 40/50C 40/70C 30/50C 20/90C

E R R L L E E R L

025 040 060 090 120 150 180 240

and 20/120C and and and and and 0/55C 10/150C 10/200C 10/290C 50/400C

EI Dimensions
Case Series EI EI EI EI EI EI EI EI EI Dial Connection Size Location Rear 2 (Plain) 2 Rear (Plain, pointed stem) 2 Rear (Threaded) 3 Rear 3 3 5 5 5 Lower Everyangle Rear Lower Everyangle

200/700F 200/1000F

and 100/370C and 100/550C**

A 2332 (53) 2332 (53) 2332 (53) 3532 (80) 3532 (80) 3532 (80) 5132 (128) 5132 (128) 5116 (128)

B 3 8 (10) 3 8 (10) 3 8 (10) 19 32 (15) 12732 (47) 19 32 (15) 23 32 (18) 11516 (49) 23 32 (18)

C 3 8 (8) 5 16 (8) 3 8 (8) 3 8 (8)


3 8 (8)

D 258 (67) 358 (92)

E 4 (6)
1

G 12132 (42) 178 (48)

H 3132 (89) 32132 (93)

S (2) (2) (2) (2) (2) (2) (2) (2) (2)

NPT
1

Hex 11 16
11

S 212 412 412 412 7 11 10 16 26 25

Overtemperature limits
Top of Range F Maximum Over Temperature 100% of span 50% of span 800F **

16 16

4 2 2 2 2 2 2

11

up to 250 251/550 551/1000

8 8 8 8 8 8

1 4 (6)

*Dual scale ranges available for all standard F ranges (3 and 5 case only) **Satisfactory for continuous service up to 800F or 425C. Can be used for intermittent service from 800 to 1000F, or 425 to 500C. Use Ashcroft Duratemp thermometers for ranges above and below those listed above. Minimum stem length for these ranges is 4. Minimum stem length for lower connection and Everyangle is 4.

NOTES: 1. Figures in parenthesis ( ) are in millimeters. All other dimensions are in inches. 2. Standard S dimensions are 212, 4, 6, 9, 12, 15, 18 and 24 inches. Standard stem diameter is 14 inch. 3. Add 1 oz. for every 2 inches of stem length.

DIMENSIONS
G
B

S
B
A

C B
S
E

BULLETIN BM-EI

All specifications are subject to change without notice. Ashcroft Inc. 2013 10/2013

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281 Fax: 203-385-0408 email: info@ashcroft.com www.ashcroft.com