CONCRETO PERMEABLE Definicin

QUE ES EL CONCRETO PERMEABLE

CONCRETO PERMEABLE Que es el concreto permeable?

Concreto con alto grado de porosidad


Asentamiento Cero

Cemento Portland (Materiales Suplementarios) Agregado Grueso Agregado fino (opcional) Agua Aditivos
Diseado para dejar pasar el agua Principal uso como material de drenaje
ACI522R-06 on Pervious Concrete A zero-slump, open-graded material consisting of portland cement, coarse aggregate, little or no fine aggregate, aggregate, admixtures, and water. The combination of these ingredients will produce a hardened material with connected pores, ranging in size from 0.08 to 0.32 pulg. (2 a 8 mm), that allow water to pass through easily. The void content can range from 18 to 35 % with typical compressive strength of 400 to 4000psi (8 to 2.8 MPa). The drainage rate of pervious concrete pavement will vary with aggregate size and density of the mixture, but will generally fall into the range of 2 to 18 gal./min/ft2 (81 ti 730 L/min/m2).

Delatte-CSU

APWA-www.svrdesign.com BASF

Permeable Concrete - Pervious Concrete - Porous Concrete - No-Fines Concrete - Gap-Graded Concrete - Enhanced Porosity Concrete - Percolating Concrete

CONCRETO PERMEABLE Antecedentes - Historia

* 1852 2 casas y 1 dique en el Reino Unido

* 1923 50 casas de dos pisos en Escocia


* 1930 1942 901 casas en Escocia

* Despus de la 2 Guerra Mundial Toda Europa


* 1950 Residencias de 5 pisos en Escocia * 1951 Investigaciones en USA * 1960s casas en Canad

Actualmente En variadas aplicaciones a nivel mundial


+No-Fines

Concrete Its properties and Applications, ACI Journal/November 1976 Ozinga

CONCRETO PERMEABLE Aplicaciones

reas de estacionamientos Caminos de acceso-entrada Aceras-veredas Senderos (andadores) Vialidades de trnsito ligero
Ozinga Ozinga
Ozinga

www.rmc-foundation.org/ www.alconcrete.org/concrete_products.aspx

Ozinga

www.vma-engineers.com

CONCRETO PERMEABLE Aplicaciones

Acotamiento (Berma) Pendiente para lluvias


Ozinga

Cunetas Control de erosin Proteccin de pendientes Control de riego


Buffenbarger

Ozinga

Ozinga

secement.org/PDFs/CT032Pervious.pdf

CONCRETO PERMEABLE Beneficios

Beneficios Medioambientales
Buen manejo de las aguas de lluvia Ecosistemas del rea de estacionamiento Disminuye el efecto del calor de isla Mayor albedo
PCA-

Beneficios Econmicos
Alternativa a mtodos costosos de manejo de aguas de lluvia Mejor uso del suelo

Beneficios Estructurales
Superficie con textura expuesta mejora la traccin Estructura de vacos proporciona seguridad Es resistente y durable

CONCRETO PERMEABLE Materiales

MATERIALES

PROPORCIONAMIENTO DE MEZCLA Materiales

Concreto Convencional

Concreto Permeable

PROPORCIONAMIENTO DE MEZCLA Materiales

CEMENTO Cemento ASTM C150 Cemento Compuesto ASTM C595, C1157

Materiales Cementantes Suplementarios: Ceniza Volante ASTM C618 Humo de Slice ASTM C1240 Escoria de Alto Horno ASTM C989

AGREGADO GRUESO No. 8 3/8 a No. 8


9.5 a 2.36 mm

No. 7 a No. 4
12.5 a 4.75 mm

AGREGADO FINO POCO O NADA

No. 67 a No. 4
19.0 a 4.75 mm

AGUA ACI 301

ADITIVOS ASTM C494 Reductor de agua Controlar Hidratacin Modificador de Viscosidad

CONCRETO PERMEABLE Rangos Tpicos de Proporcionamiento

Caracterstica Cementante, kg/m3 Agregado grueso, kg/m3

Rango

270 - 415
1,190 - 1,480

Relacin agua/cemento (en peso)


Relacin agregado grueso/cemento (en peso) Relacin agregados fino/grueso (en peso)

0.35 - 0.45
4 a 4.5:1 0 a 1:1

CONCRETO PERMEABLE Propiedades Tpicas

Propiedad
Asentamiento, mm Peso unitario, kg/m3 Tiempo de fraguado, hora

Rango

0 - 20 1,600 - 2,000
1

Porosidad, % (en volumen) Permeabilidad, cm/seg (lt/m2/min) Resistencia a compresin, MPa


Resistencia a flexin, MPa Contraccin

15 - 25 0.20 - 0.54 (120 - 320)


3.5 - 28 1.0 - 3.8 200 10-6

PROPORCIONAMIENTO DE MEZCLA Concreto Convencional vs Concreto Permeable

PROPORCIONAMIENTO

PROPORCIONAMIENTO DE MEZCLA Concreto Convencional vs Concreto Permeable

Standard Practice for Selecting Proportions for Normal, Heavyweight, and Mass Concrete (ACI 211.1-91)
(Reapproved 2002) Reported by ACI Committee 211

Guide for Selection Proportions For No-Slump Concrete


(ACI 211.3R-02) Reported by ACI Committee 211
APPENDIX 6 PERVIOUS CONCRETE MIXTURE PROPORTIONING

PROPORCIONAMIENTO DE MEZCLA Concreto Convencional

ACI 211.1 Seleccin del Agua de Mezclado

PROPORCIONAMIENTO DE MEZCLA Concreto Convencional

ACI 211.1 a/c vs Resistencia a Compresin


45

Resistencia a compresin a 28 das, MPa

40

35
Sin aire incorporado

30

25

Con aire incorporado

20

15

10

0.35

0.4

0.45

0.5

0.55

0.6

0.65

0.7

0.75

0.8

0.85

Relacin agua/cemento, en peso

PROPORCIONAMIENTO DE MEZCLA Concreto Convencional

ACI 211.1 Agregado Grueso

PROPORCIONAMIENTO DE MEZCLA Concreto Convencional

ACI 211.1 Agregado Fino

Calcular la Arena por:


Volmenes Absolutos

Convertir a Pesos

1 metro cbico
MEZCLAS DE PRUEBA

PROPORCIONAMIENTO DE MEZCLA Concreto Convencional

ACI 211.1 Proporcionamiento de Mezcla de Concreto


Trabajable Resistencia Durable

PROPORCIONAMIENTO DE MEZCLA Concreto Permeable

ACI 211.3R Proporcionamiento de Mezcla Concreto Permeable


Diseo de Mezclas
No es por a/c

Contenido de Vacos
Velocidad de filtracin Capacidad de Almacenamiento Resistencia, durabilidad

Volumen de Pasta
Adherencia entre partculas de agregado
Trabajabilidad suficiente Proporcionamiento por Volumen Absoluto (1 m3)

PROPORCIONAMIENTO DE MEZCLA Concreto Permeable

ACI 211.3R Criterios para el Proporcionamiento


ASTM C 33 No. 8 No. 7 No. 67 3/8 a No. 8 a No. 4 a No. 4 9.5 a 2.36 mm 12.5 a 4.75 mm 19.0 a 4.75 mm

No. 67

24 MPa (245 kg/cm2)

Relacin agua/cemento 0.35 0.45

NAA; NATIONAL AGGREGATES ASSOCIATION NRMCA: NATIONAL READY MIXED CONCRETE ASSOCIATION

PROPORCIONAMIENTO DE MEZCLA Concreto Permeable

ACI 211.3R Volumen de Pasta para un Contenido de Vacos

1 m3 = Vpasta + Vgrava + Vvacos Vpasta = Vcemento + Vagua


Vv

Vpasta = Vpasta =
Vp

C + 3.15 x 1000 C + 3.15 x 1000

A 1 x 1000 (A/C)/C 1 x 1000

CEMENTO

AGUA

GRAVA
MEZCLAS DE PRUEBA

GRAVA - PVSC

PROPORCIONAMIENTO DE MEZCLA Concreto Permeable


El Control de la Humedad es CRTICO

Demasiado Seco - Muy Poca Agua

Correcto Agua Adecuada


Buena Humedad

BUENA SUPERFICIE

Buena Adherencia entre Agregados Buena Compactacin Poco o Nada de Bolas Nada de Grandes Agujeros Nada de reas Selladas Vacos Uniformes-Consistentes Buena Apariencia

Demasiado Hmedo Mucha Agua

PROPORCIONAMIENTO DE MEZCLA Concreto Permeable


El Control de la Humedad es CRTICO

Demasiado Cemento Demasiada Agua

Demasiada Pasta

NO ES PERMEABLE

Superficie Pobre
Ozinga

PROPORCIONAMIENTO DE MEZCLA Concreto Permeable


El Control de la Humedad es CRTICO

Mezcla Seca

No Pasta entre Agregados No Pasta en Superficie

NO ES PERMEABLE

Superficie Pobre
Ozinga

PROPORCIONAMIENTO DE MEZCLA Concreto Permeable


El Control de la Humedad es CRTICO

Pobre Mezclado

Pobre Compactacin

NO ES PERMEABLE

Superficie Pobre
Ozinga

PROPORCIONAMIENTO DE MEZCLA Concreto Permeable


El Control de la Humedad es CRTICO TEXTURA FINAL ADECUADA

Buena Superficie: Circulacin de Vehculos Caminar Paseos en Bicicleta Andar en Patinetas

Seguridad: Buena Friccin Hmedo o Seco Brillante y Fresco No Charcos No Hidroplaneo

Ozinga

CONCRETO PERMEABLE Normas ASTM

MTODOS DE PRUEBA

MTODOS DE PRUEBA ASTM Concreto Convencional

Pruebas de Laboratorio y Campo


Muestreo (C172) Consistencia (C138) Contenido de Aire (C231, C138, C173) Densidad (Peso Unitario) (C138) Moldeado (C31, C192) Compactacin (C31, C192)

Pruebas del Concreto Endurecido


Resistencia a Compresin (C39) Resistencia a Flexin (C78) Resistencia a Tensin (C496) Mdulo Elstico (C469) Permeabilidad

MTODOS DE PRUEBA Nuevos Mtodos

ASTM C09.49 Concrete and Concrete Aggregates PERVIOUS CONCRETE


Densidad del Concreto en Estado Fresco

Densidad y Porosidad del Concreto en Estado Endurecido


Permeabilidad en Campo (Velocidad de Infiltracin) Resistencia a Compresin Resistencia a Flexin Durabilidad de la Superficie

MTODOS DE PRUEBA ASTM C 1688 2008 (OCTUBRE)

ASTM C1688 STANDARD TEST METHOD FOR DENSITY AND VOID CONTENT OF FRESHLY MIXED PERVIOUS CONCRETE

Recipiente de 7 lt Martillo de Compactacin del Proctor Standard (ASTM D698) Llenado en dos capas Cada capa compactada con 20 Golpes

Offenberg-aci spring 2009

Muestreo ASTM C172

MTODOS DE PRUEBA ASTM - Mtodos Alternativos

ASTM TESTING FRESH DENSITY

ASTM C138 Procedimiento de Varillado


(Rodding Procedure)

ASTM C29 Procedimiento de Asentado


(Jigging Procedure )

MTODOS DE PRUEBA ASTM - Mtodos Alternativos

ASTM DENSIDAD, POROSIDAD Y ESPESOR

ASTM C42

Obtaining and Testing Drilled Cores and sawed Beams of Concrete

www.waterbucket.ca/rm/sites/wbcrm/documents/media/92.pdf

Offenberg-aci spring 2009

www.waterbucket.ca/rm/sites/wbcrm/documents/media/92.pdf

MTODOS DE PRUEBA ASTM C 1709 2009 - (OCTUBRE 2)

ASTM 1701M-09 STANDARD TEST METHOD FOR INFILTRATION RATE OF IN PLACE PERVIOUS CONCRETE
ASTM Approves New Pervious Concrete Test Standard A new ASTM test standard ASTM C1701/C1701M 09 Standard Test Method for Infiltration Rate of In Place Pervious Concrete has been finalized. .This is the second ASTM test method to be standardized. ..In addition, the subcommittee is working on test methods on hardened density, strength and surface durability. Copies of the standard are available beginning October 2 via ASTMs Web site at http://www.astm.org/Standards/C1701.htm.

Concrete Magazine Construction

EN LABORATORIO

Characteristics of Porous Concrete-Mdewoolkar - Jan09

ACI522R-06

MTODOS DE PRUEBA C09.49 Pervious Concrete - ASTM Nuevos Mtodos

ASTM RESISTENCIA A COMPRESIN


Desarrollar el tipo de prueba a compresin, las tcnicas de consolidacin, material de cabeceo y seleccin del tamao adecuado del cilindro.

ASTM RESISTENCIA A FLEXIN


La nueva prueba no debe diferir radicalmente del mtodo existente. La direccin de carga debe corresponder con la direccin de colocacin. La nueva prueba a desarrollar debe ser para mezclas de baja densidad y alta permeabilidad. Dos versiones de prueba, una de seccin simple para el concreto permeable y una seccin ms compleja para el concreto permeable reforzado con fibra. Seleccionar la longitud del claro a usar, el ancho de la placa que distribuye la carga, y evaluar el post-agrietamiento en caso de concreto permeable reforzado con fibras.

ASTM DENSIDAD Y POROSIDAD EN ESTADO ENDURECIDO

CONCRETO PERMEABLE Diseo

DISEO

CONCRETO PERMEABLE Seccin Tpica

100 200 mm
(4 - 8)

Concreto permeable
Espesor: por diseo

600 900 mm
(24 36)

Reservorio de piedra
(Grava 1 a 3)

25 50 mm
(1 2) Filtracin 13 mm/hr

Filtro grueso (Grava ) Filtro de tela Suelo inalterado (Tipo A)

e min: 4 e min: 5 e min: 6 e min: 8

Peatones Autos Camionetas Camiones

CONCRETO PERMEABLE Diseo del Pavimento - Bases

Diseo Hidrulico Diseo Estructural Elegir la de mayor espesor


Otras consideraciones
Evitar instalar en reas de trfico pesado Pendientes planas o suaves (menos de 5%) Filtro de tela colocarse bajo y a los lados del reservorio de piedra Usar un solo tamao en el reservorio de piedra

Diseo eficiente:
Buen manejo del agua Soportar la carga de trfico
Secuencia Tpica de Diseo Verificar el suelo Diseo estructural

Diseo hidrolgico

CONCRETO PERMEABLE Diseo Hidrolgico Consideraciones

Precipitacin

Volumen, distribucin Tasa de infiltracin del suelo Perodo de retorno (2 y 10 aos)

Google: Imgenes: stormwater

Infiltracin
Cantidad de precipitacin que pueda penetrar al suelo Tipo de suelo Humedad Nivel fretico
Velocidad de infiltracin
Velocidad de infiltracin (suelo) mm/hr 13 25 3 13 0.3 3
Zona de capilaridad Zona saturada bajo el nivel fretico Agua subterrnea Google: Imgenes: water table ground water (adaptado) Precipitacin

Recarga al nivel fretico

Zona de suelo

Nivel fretico

Alta (Suelo arenoso) Intermedio (Arcilla, limo) Bajo (Arcillas, franco arcilloso)

Zona sin saturar

PCA-NRMCA

NRMCA-PCA

CONCRETO PERMEABLE Diseo Hidrolgico - Consideraciones

Capacidad de almacenamiento

Zona de almacenamiento

Pendientes
Reduccin de la capacidad de almacenamiento

Concreto Permeable

Reservorio permeable Filtro de tela

Suelo

PCA-NRMCA

Espesor de pavimento = 10 cm Porosidad = 15% Capa permeable = 15 cm Porosidad = 40% Almacenamiento 15% x 10 cm = 1.5 cm 40% x 15 cm = 6.0 cm Total = 7.5 cm

Soluciones

% Vol = e / (2 p L) Presa de detencin Espesor de pavimento (e) = 15 cm Longitud (L) = 30 m Pendiente (p) = 1% % Volumen

rea de pavimento: 1000 m2 Volumen Almacenado: 75 m3

% Vol = 15/(2x 0.01 x 30) Terrazas escalonadas % Volumen = 25%

CONCRETO PERMEABLE Diseo Estructural Procedimientos de diseo


ACI 330R-08

Guide for the Design and Construction Of Concrete Parking Lots


Reported by ACI Committee 325 PCA-NRMCA

Resistencia a flexin mnima: 3.4 MPa

ACI 325.9R-91

Guide for Construction of Concrete Pavements and Concrete Bases


Reported by ACI Committee 325 PCA-NRMCA

No es un documento de diseo

ACI 325.12R-02

Guide for Design of Jointed Concrete Pavements For Streets and Local Roads
Reported by ACI Committee 325

Resistencia a flexin mnima: 3.4 MPa

ACI 522R-06

Pervious Concrete
Reported by ACI Committee 522

Captulo 6 AASHTO PCA

PCA-NRMCA

CONCRETO PERMEABLE Diseo Estructural - Consideraciones

Delatte

PCA-actualizado Delatte

CONCRETO PERMEABLE Proceso Constructivo

PROCESO CONSTRUCTIVO

CONCRETO PERMEABLE Proceso constructivo Preparacin Colocacin - Enrasado -

CONCRETO PERMEABLE Proceso constructivo Compactacin - Junta - Curado

CONCRETO PERMEABLE Proceso constructivo Control de calidad

CONCRETO PERMEABLE Mantenimiento

MANTENIMIENTO

CONCRETO PERMEABLE Mantenimiento

En caso de obstrucciones Es posible restablecer la permeabilidad La Limpieza Lavado a Presin o con Aspirado Equipo de Limpieza Convencional
www.concreteresotces.net

Limpieza con Agua a Presin

Limpieza Hidrulica con Boquilla Bueno para superficies

Limpieza hidrulica Bueno para Musgos

CONCRETO PERMEABLE Precauciones en su uso

EL XITO HIDROLGICO Y ESTRUCTURAL


Depender de la adecuada seleccin de los materiales, el diseo, la instalacin y su mantenimiento, o mal uso

Basf

LAS FALLAS
DEGRADACIN ESTRUCTURAL Y OBSTRUCCIN
Descuido de alguno de estos pasos
Basf

Offenberg

Offenberg

INVESTIGACIN EXPERIMENTAL Alcance

INVESTIGACIN EXPERIMENTAL

Normas ASTM INVESTIGACIN EXPERIMENTAL Alcance

INVESTIGACIN EXPERIMENTAL

C 39

C 469

C 496

C 78

Normas ASTM INVESTIGACIN EXPERIMENTAL Alcance

INVESTIGACIN EXPERIMENTAL

INVESTIGACIN EXPERIMENTAL Alcance

2 Tamaos de Agregado
No. 8 (3/8-9.5 mm) y No. 67 (3/4-19.0 mm)

1 Tipo de Cemento
CPC, Densidad 3.15

Con 1 Aditivo
Agente Viscoso

2 Contenido de Vacos
15% y 20%

Propiedades en Estado Endurecido


Resistencia a Compresin, Mdulo de Elasticidad, Resistencia a Tensin por Compresin Diametral, Resistencia a Flexin en Vigas, y PERMEABILIDAD

INVESTIGACIN EXPERIMENTAL Proporcionamiento por m3

Proporcionamiento/m3 % Vaco % Arena

Aditivo/ Agente

Mezcla

M1 M2 M3

3/8" 3/8" 3/4"

TMA

Cemento (kg) 350

Agua (kg) 122

Grava (kg) 1393

Arena (kg)

Aditivo (ml)

15% 20% 5% 15% 10%

320
350 350 viscoso

112
122 122 122

1259
1274 1171 1171

68 144 133 133 1837

M4
M5

3/4"
3/4"

20% 10%
20% 10%

350

a/c : 0.35 Agregado/cemento 4

INVESTIGACIN EXPERIMENTAL Propiedades en Estado Fresco

Propiedades en estado fresco

ID M1 M2 M3 M4 M5

Caractersticas de la mezcla

P. U.
Kg/m3

Prueba

3/8-Vacos 15% 3/8-Vacos 20%-Arena 5%

1918 1850 1970 1926 1921


Peso Unitario Asentamiento

3/4-Vacos 15%-Arena 10% 3/4-Vacos 20%-Arena 10%

3/4-Vacos 20%-Arena 10% + Agente Viscoso

P. U. Peso Unitario

INVESTIGACIN EXPERIMENTAL Resultados a compresin (fc) en kg/cm2

Resistencia a compresin, kg/cm2

250
M1 M3 M5 M2 M4

Prueba
215 178 176 158 153 145 176 173

200

150

144 138

100

50
M1 M2 M3 M4 M5 M1 M2 M3 M4 M5

Cilindros 150 () x 300 (H) mm

0 7 28

Edad, das
M1: 3/8-Vacos 15% M2: 3/8-Vacos 20%-Arena 5% M3: 3/4-Vacos 15%-Arena 10% M4: 3/4-Vacos 20%-Arena 10% M5: 3/4-Vacos 20%-Arena 10% + Agente Viscoso

INVESTIGACIN EXPERIMENTAL Resumen de resultados a 28 das de prueba

Resultados % Vaco % Arena Mezcla


Aditivo/ Agente

TMA

fc
(kg/cm2)

ft
(kg/cm2)

f t/ f c
(kg/cm2)

ff
(kg/cm2)

ff/ fc
(kg/cm2)

E
(kg/cm2)

k
(cm/seg)

M1 M2
M3 M4 M5

3/8 3/8"
3/4" 3/4

15% 20% 5%
15% 10% 20% 10% 10% viscoso

176
145 215 176 173

19
14 20 17 15

11 10 9 10 9

35
32 46

20 22 21 23 23

122,006 91,665 113,529

0.41 0.49 0.46 0.52 0.52

40
39

113,902
110,565

3/4 20%

ff 10% - 20% fc ft 8% - 12% fc

INVESTIGACIN EXPERIMENTAL Conclusiones

CONCLUSIONES

CONCRETO PERMEABLE Conclusiones

El concreto permeable es un tipo especial de concreto, considerado un material de construccin sostenible Se puede suministrar mediante concreteras convencionales, sin embargo, es indispensable la experiencia y familiaridad necesaria en el manejo de este tipo de concreto Es necesario mantenimiento caracterstica de permeabilidad para mantener su

Impulsar su uso se requiere de investigaciones futuras

25 AOS DEL ACI CAPTULO PERUANO

CARLOS AIRE
ESTRUCTURAS Y MATERIALES INSTITUTO DE INGENIERA - UNAM

aire@pumas.iingen.unam.mx

Pervious Concrete Demo at Southface Eco Office-Departs Main Lobby- ACI Sprong 2007-Atlanta

CONCRETO PERMEABLE DEMO

Вам также может понравиться