Вы находитесь на странице: 1из 72

SERVICE MANUAL

CODE: 00ZARFX13/S2E

DIGITAL MULTIFUNCTIONAL SYSTEM OPTION FACSIMILE EXPANSION KIT

MODEL

AR-FX13

CONTENTS

[1] PRODUCT OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 [2] SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 [3] INSTALLATION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 [4] SIMULATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 [5] FAX SOFT SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 [6] TROUBLE CODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 [7] CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 PARTS GUIDE

Parts marked with are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.

SHARP CORPORATION

This document has been published to be used for after sales service only. The contents are subject to change without notice.

[1] PRODUCT OUTLINE


This unit provides the FAX function when installed to the following machines: Machines to install this unit : AR-M200 AR-M201 AR-208S AR-208D

[2] SPECIFICATIONS
Large item Middle item Communication Electronic system transmission system Small item Electronic transmission time Compression/ Extraction system MODEM speed Mutual communication Used line R-key operation when setting PBX PBX setting Used line number Connection form Sub item Specifications Less than 3 sec (Super G3 mode, 33600bps) Less than 7 sec (G3 ECM mode, 14400bps) MH, MR, MMR, JBIG 33600bps - 2400bps (Automatic fall-back) Super G3/G3 Public switched telephone network (PSTN), Private branch exchange (PBX) Yes (Germany only) Yes (Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway) 1 line For 1 line of telephone; FAX machine External telephone Yes Specifying the destination number Resolution Density Transmission start time Polling receive Cover addition setting Send document scan system Auto send function to a predetermined telephone number Max. 50 digits One-touch key Max. 18 items Max. 40 digits Max. 20 characters 0 - 3 characters Max. speed: 33600bps/ High speed: 14400bps/ Middle speed: 9600bps/ Low speed: 4800bps NO/ Mode 1/ Mode 2/ Mode 3 One-touch dial key

Transmission functions

Transmission operation

ECM Items which can be selected and registered by user when transmitting

Auto send function Application send function Chain dial Rapid key dial

Registration key Number of items Number of digits of destination number Destinationregistration name Retrieval characters Communication start speed International communication mode Transmission method

AR-FX13 PRODUCT OUTLINE 1 - 1

Large item Transmission functions

Middle item Application send function

Small item Speed dial

Group dial

Address book send

Sub item Number of items Number of digit of destination number Destination registration name Retrieval characters Communication start speed International communication mode Transmission method Registration key Number of groups which can be registered Destination registration name Number of stations which can be registered in one group Numbers which can be registered Retrieval characters Transmission method Retrieval target

Specifications 100 items (Reduction number 00 - 99) 40 digits 20 characters 0 - 3 characters Max. speed: 33600bps/ High speed: 14400bps/ Meddle speed: 9600bps/ Low speed: 4800bps NO/ Mode 1/ Mode 2/ Mode 3 Speed dial key + (00 - 99) + Start key One-touch dial key 18 items (One-touch dial + Group dial) 20 characters Max. 100 stations in one group (Max. total items which can be registered: 150 items) Destination numbers registered in one-touch dial and speed dial, 10-key dial 0 - 3 characters Group dial key Speed dial One-touch dial Group dial SEARCH key 0 - 3 characters Inch series: 8.5" AB series: 210mm 500mm (Only from RSPF, with user support) RSPF: Single surface scan AB series: A4 Inch series: Letter (8.5" x 11")/Legal (8.5" x 14") (Default: Letter (8.5" x 11")) Yes 256 gradations Manual 5 steps Standard/Fine/Super Fine/Fine + Half-tone/Super Fine + Half-tone (Default: Standard) Light/Medium/Dark Scan density Standard: 8dot x 3.85 line/mm Fine: 8dot x 7.7 line/mm Super Fine: 8dot x 15.4 line/mm Half-tone: Scan in 256 gradations Book document scan/send function from the document table (OC). In one send job, the send document size is fixed.

Send functions

Document scan function

Document size

Retrieval key Retrieval character Max. document width Max. document length Send document size

Document size specification Half-tone reproduction Half-tone Resolution selection

Scan density select function Scan resolution select function

Density select Selectable image quality mode Resolution select

Document table scan (OC send) function

AR-FX13 SPECIFICATIONS 2 - 1

Large item Send functions

Middle item Small item Send document Sender registration/ information adding send function function Send header function Page counter function Cover adding function

Basic send functions

Send message adding function Index function Direct send function Memory send function

Quick online send function Auto resend function

Application send function

Long document send function Manual send function Time specifying send function

Group send function

Serial broadcast function Duplex send function

Sub item Specifications Sender telephone 20 digits number Sender registration 36 characters name Header display content Sender number registered in sender registration/ Sender name/ Send date and time/ page Adding position Top right (The right edge) Adding form P. XXX (Max. 999) Display items Date and time Destination name (Max. 20 characters) Destination number (Max. 40 digits) Sender name (Max. 20 characters) Sender number (Max. 20 digits) Send quantity (3 digits) Send message (When send message adding function is used) Fixed message NO MESSAGE/CONFIDENTIAL/PLS. DISTRIBUTE/ URGENT/PLS. CALL BACK/IMPORTANT Yes (Max. 10 kinds in printable area) Yes Send form Send reservation Number of items of Time specifying send send reservation Group send Serial broadcast Max. 52 items (excluding redial) Group send and broadcast are treated as one item. Operation when Document scan stop memory full Memory full display Job continuation check Job continuation: Scanned document data are sent. Job stop: Scanned document data are deleted. In either case, document is held in RSPF and not discharged. Valid when memory mode is ON. Scan of send document data and send are performed together. When busy tone Redial is performed according to the setting of detected "Number/interval of redial when busy." When no response Redial is performed according to the setting of (CED/ FSK signal are "Number/ interval of resend in communication error." not detected) Communication error Supports up to 500mm. When this length is exceeded, "PAPER JAM" occurs. This function allows to switch to FAX manually when off-hook with document set. Available Memory send, Polling, serial broadcast, serial send communication request Number of set items Max. 5 items Set range 00:00 - 23:59 (Unit: 1 min) Day of week 8 kinds (From Monday to Sunday, and no specification) A message is sent sequentially to two or more destinations registered in group dial. (Max. 52 destinations can be registered in one group.) Broadcast send Max. 100 items destination Valid only in duplex support models. Direct send and scan from OC cannot be made. Send document size A4/ Letter/ Legal size

AR-FX13 SPECIFICATIONS 2 - 2

Large item Incoming functions system

Middle item Small item Incoming detection Call signal detection function function Remote select function by CNG detection Application Distinctive Ringing incoming function function

Sub item

Specifications Call bell is distinguished from net call signals to judge incoming. Receive is started when CNG signal is detected in standby with external telephone used. (North America) Conforms to the call distinguishing function provided by the local telephone company. (Europe, Australia, New Zealand) Only distinction of TEL/FAX (When FAX distinction of ON/OFF) (Default: OFF) OFF/STANDARD/Pattern 1 - 5 (North America) Incoming is rejected when remaining memory capacity is less than 7%. OFF/LOW/MIDDLE/HIGH OFF/LOW/MIDDLE/HIGH Follows setting on the main unit. Junk stations are registered to be rejected. Max. 10 items Auto (AUTO) Manual (MAN.) Answering machine (A.M.) The line is switched to FAX by detection of call signal. (receive standby mode) AUTO: 0 - 9 times (Default: 2 times) No During Simulation by serviceman Insufficient memory capacity During menu During memory status display Receive is manually started. 0 - 9 times (Default: 0 times) Receive data are accumulated in memory, and outputted when output conditions are satisfied. Countermeasure against print inhibit state. No recording paper Recording paper jam During copy/print job During printing by printer Cover open Paper empty, size error No

Call bell pattern Incoming reject function Call sound volume adjustment function Alarm sound volume adjustment function Key sound volume setting Junk FAX protection function Receive functions system Receive function Receive standby mode

Volume select Volume select

Number of registrations

Basic receive function

Auto receive function Number of calls Tel/FAX auto select Incoming reject conditions

Manual receive function Memory receive function

Number of calls

Substitution receive function

Forcible memory receive function Overtake output No function Receive document Auto reduction/ divided Auto reduction function When the reference line number is in the specified output function receive function range. Divided receive When the reference line number exceeds the function specified range. Polling receive The remote machine must be provided with polling function (Send request function. Communication is allowed with an other function) company machine. Sequential send Polling is made to two or more specified destinations. request (Polling) Number of items of destination registration: Max. 100 communication items Remote send Scanned document data in memory are sent automatically by send request from the remote machine. Protection function Check by sender number Check by allow number

AR-FX13 SPECIFICATIONS 2 - 3

Large item Receive functions system

Middle item Print system

Small item Recording paper

Sub item Recordable size Recording paper setting Paper feed Recording paper size detection Recording paper empty detection

Specifications A4/8.5" x 11"/8.5" x 14" AUTO/TRAY 1/TRAY 2 (When the option installed) (In AUTO, TRAY1 has priority.) (Default: AUTO) (North America) Paper feed by tray (Excluding multi manual feed) The recording paper length is detected. If the size differs, a paper size error occurs. Detected by a paper pickup error. Available only in the duplex function support models. Receive data are transferred to the registered station. 1 item 40 digits Countermeasures against an error Paper jam No toner cartridge No toner During toner supply Toner empty No recording paper Yes 50 digits End 20 digits Yes (Fixed to 2sec) Yes (Set by soft switch) Select number (1 digit) + [**] (0 - 9)

Duplex receive Transfer function Number of registered transfer destination Registered telephone number Local transfer

Telephone functions system

Main unit On-hook dial function telephone function Manual redial function Pause function Pulse/Tone select function External telephone Select function by DTMF connection function Report list Report output function

Max. memory digit Display digits

Record table system

Report select

Recording table auto print function Communication report list

Number of items Report select

TIMER LIST ACTIVITY REPORT TELEPHONE# LIST GROUP LIST PASSCODE LIST JUNK FAX# LIST USER PROGRAM LIST Auto print for every 50 items of send/receive total. Send report list Receive report list Serial broadcast send report list Image memory addition ALWAYS PRINTS ERROR ONLY NEVER PRINTS

Print status select

AR-FX13 SPECIFICATIONS 2 - 4

Large item Memory functions system

Middle item Memory outline

Small item Memory capacity

Data storage area/ backup when service interruption (Recorded Data other than image data, receive data) Treatment when memory full Quick online

Memory send

Service functions system

Memory status check function Memory content check function Document jam Simulation function Counter function

Others

Environmental functions

Auto clear

Auto shut -off Date and time setting function

Flash memory (Data are retained when the power is turned off or when the battery is exhausted.) SRAM (Data are retained when the power is turned off, but deleted when the battery is exhausted with the power OFF.) Memory full on the first Send cancel without call-out page Memory full on the The line is shut-off after sending the last page of second or later page scanned data. Memory full on the first Send cancel page Memory full on the Send/Cancel is selected depending on the select second or later page menu display. Send: The line is shut off after sending the scanned data. Cancel: Cancel even scanned data. Yes (The remaining memory capacity (%) is displayed on the LCD.) Not-sent job is displayed on the LCD. (Cancel is possible.) Error LED, LCD message are displayed. Send/receive of specified signals, commands, and image data are performed without a remote machine. Communication Number of send pages counter Number of receive pages Number of output pages Send time Receive time Conforms to the main unit setting. When the operation is left for 1 min or more, the display returns to the main menu. Conforms to the main unit setting. (North America) Month/ Day/ Year/ Day of week/ O'clock/ minute (Europe, Australia, New Zealand) Day/ Month/ Year/ Day of week/ O'clock/ minute STANDARD/FINE/SUPER FINE 3SEC/1SEC/NO BEEP

Sub item Standard memory Option Document quantity to be stored Image data

Specifications 2MB No A4 standard documents 120 pages

Image priority function BEEP LENGTH (Communication end sound length) setting Auto summer time setting

(North America) Second Sunday of March AM2:00 3:00, First Sunday of November AM2:00 1:00 (Default: OFF) (Europe) Last Sunday of March AM1:00 2:00, Last Sunday of October AM1:00 0:00 (Default: ON) (Australia, New Zealand) Last Sunday of October AM2:00 3:00, Last Sunday of March AM3:00 2:00 (Default: ON) Conforms to the main unit setting.

Multi language function

AR-FX13 SPECIFICATIONS 2 - 5

[3] INSTALLATION PROCEDURE


<Before installation> For improvement of workability, some description in this manual as well as components and accessories may change without prior notice. In this case, refer to the service manual. Turn off the main switch of the copier and then remove the power plug of the copier from the outlet.

(2) Remove the rear cabinet.


1) Unscrew the screw and remove the rear cabinet shielding plate. (Save the screw.) 2) Unscrew three screws and remove the rear cabinet. (Save the screws.)

1. Parts included

1 2

Speaker unit: 1

Sponge: 1 FAX Modem PWB: 1

(3) Attach the speaker unit.


Attach the speaker unit using a supplied screw as shown below.
Key sheet: 1 Cable: 1

FAX keyboard: 1

Ground angle: 1

Line Adapter: 1 (Australia/New Zealand) For North America

Line cable: 1

Gasket: 2

For other than North America

(4) Attach the FAX modem PWB.


1) When RSPF is installed, unscrew the screw holding the RSPF ground terminal. (Save the screw.) 2) Insert two supplied screws and tighten them loosely as shown below.

Screws (M3x6): 5

Screws (M3x6): 6

North America FCC label: 1 Australia/New Zealand A-tick label: 1

Core: 1

Operation Manual: 1

3) Attach the sponge around the bent portion of the FFC cable as shown in the figure.

Remove all pieces of fixing tape and fixing materials from the finisher.

2. Installation procedure
(1) Detach the RSPF or OC.
Detach the RSPF or OC from the copier and softly place it on top of the original table as shown below.

AR-FX13 INSTALLATION PROCEDURE 3 - 1

4) Align the top frame portion of the FAX modem PWB with the screw hole at the back of the speaker unit. 5) Place the holes of the bottom portion of the FAX modem PWB onto the loosely tightened screws. Slide the PWB to left to secure as shown below. 6) When RSPF is installed, secure the RSPF ground terminal and the FAX modem PWB onto the copier using the screw removed earlier in (4)-1). When OC is installed, secure the FAX modem PWB onto the copier using a supplied screw. 7) Secure the FAX modem PWB onto the copier using a supplied screw. 8) Tighten two loosely tightened screws completely. 9) Secure the ground angle using a supplied screw.

2) Attach two Gasket as shown.


Putting standard

Putting standard Gasket Gasket

(7) Reattach the rear cabinet.


1) Reattach the rear cabinet and secure it using three screws.

7 4

2) Reattach the rear cabinet shielding plate and secure it using one screw removed earlier. Reattach the RSPF detached in Step (1).

1 5
Ground angle

(5) Connect the cable, and the speaker connector


Connect the copier and the FAX modem PWB with the cable. Fix the snap band to the FAX PWB. NOTE: Connect the speaker connector to the FAX modem PWB.
Cut-out portion

(8) Peel off the dummy key sheet.


Open the RSPF or OC. Peel the edge of the dummy key sheet using a tool such as a retractable knife, and then peel off the entire key sheet.

Speaker connector

Cable

(6) Work the rear cabinet, and attach the gasket.


1) Cut and remove the cut-out portion from the rear cabinet using a tool such as nippers. (Be careful with the tools direction so that the cut surface is flat.)

AR-FX13 INSTALLATION PROCEDURE 3 - 2

(9) Remove the dummy keyboard.


Unscrew the screw, and remove the dummy keyboard with a tool like a pillar as shown below. (Save the screw.)

(12) Set the destination.


1) Execute SIM 66-01. 2) Set the following values to SW80-1 8 of the FAX soft switch. U.S.A. (10110101) Canada (00100000) U.K. (10110100) Germany (00000100) France (00111101) Sweden (10100101) Spain (10100000) Italy (01011001) Switzerland (10100110) Finland (00111100) Denmark (00110001) Norway (10000010)

(10) Attach the FAX keyboard.


1) Remove the tape which is fixing the harness to the operation panel. 2) Connect the copier cable to the FAX keyboard. Note that the cable should be folded as shown below and placed under the keyboard. 3) Place the FAX keyboard and secure it using the screw removed earlier. 4) Affix the key sheet to the FAX keyboard.

Netherlands (01111011) Luxembourg (01101001) Belgium (00001111) Australia (00001001) New Zealand (01111110) 3) Only for U.K., France, Netherlands, Belgium, Luxembourg, set the FAX soft SW67-1 to 0.

(13) Connect the FAX modem PWB line cable.


Wrap the line cable twice around the supplied core, and connect it to the FAX modem PWB as shown.

4 3

Putting standard

(11) Paste the label on the rear cabinet of the copier.


Paste the FCC label on the position shown in the illustration. In order to manifest the compliance with FCC Part 68 and ICES-03. it is required to provide the machine with the FCC Registration Number (USA), Ringer Equivalence (USA) and Ringer Equivalence (Canada). After installing the FAX expansion kit in the machine, please put the registration label, packed with the kit, on the prescribed location.

FCC label FCC label

Putting standard

Insert the power plug of the copier to the outlet and turn on the main switch of the copier. Then, carry out the following procedure. AR-FX13 INSTALLATION PROCEDURE 3 - 3

[4] SIMULATION
1. Entering the simulation mode
To enter the serviceman simulation mode, press the keys as follows: [#] key [] key [Clear] key [] key To cancel the simulation mode, press the [Clear All] key.

2. Key rule
[Numeric] key: Entry of MAIN CODE/SUB CODE Selection of an item Setup of an adjustment value in case of simulations for adjustment [ ][ ] key: Selection of MAIN CODE/SUB CODE Selection of an item [ENTER]/[OK]/[START] key: Settlement <In case of simulations for print> [ENTER]/[OK] key: Settlement (Without print) [START] key: Settlement/Print [Clear] key: (Interrupting operation check) Returns to the upper hierarchy. In case of simulation of operation check, terminates the operations. [Clear All] key: Exits from the simulation mode. For a simulation of adjustment, the display returns to the initial display (00-00).

3. List of simulations
Main code 22 24 46 Sub code 11 10 12 13 14 15 39 66 01 02 03 04 05 07 FAX counter clear Density adjustment in the FAX mode (Collective adjustment) FAX mode density adjustment (Normal text) FAX mode density adjustment (Fine text) FAX mode density adjustment (Super fine) FAX mode sharpness adjustment FAX soft SW setting FAX soft SW initializing (excluding the adjustment values) FAX PWB memory check Signal send mode (Max. value) Signal send mode (Soft SW set value) Image memory content print Contents FAX-related counter display Main code 66 Sub code 10 11 12 13 17 18 21 24 30 33 34 37 38 Contents Image memory content clear 300bps signal send (Max. value) 300bps signal send (Soft SW set value) Dial test DTMF signal send (Max. value) DTMF signal send (Soft SW set value) FAX information print FAST SRAM clear TEL/LIU status change check Signal detection check Communication time measurement Speaker sound volume setting Time setting/check

AR-FX13 SIMULATION 4 - 1

4. Descriptions of various simulations


Main code 22 Sub code 11 Contents FAX-related counter display Details of function/operation [Function] The FAX-related counter is displayed. [Operation] 1) Initial display SELECT COUNTER 1:PAGE 2:TIME [Clear] key: Returns to the main-sub code input display. 2) Select 1 SEND PAGE:xxx,xxx RECV PAGE:xxx,xxx ("xxx,xxx" is the current value.) [Clear] key: Returns to "1) Initial display". 24 10 FAX counter clear 2) Select 2 TX TIME:xxxxx:xx.xx RX TIME:xxxxx:xx.xx ("xxxxx: xxx. xx" is the current value.) [Clear] key: Returns to "1) Initial display".

[Function] When [ENTER]/[OK]/[START] key is pressed, the FAX count value is set to 0 and "000,000" is displayed on the LCD. [Operation] 1) Initial display 24-10 FAX CLR. CLEARED 000,000

46

12

Density adjustment in the FAX mode (Collective adjustment)

[Function] When [START] key is pressed, scan is executed with the entered exposure adjustment value and the data stored on the FAX side is rewritten into the entered value. All data of the exposure adjustment values are rewritten into the same value. For the density adjustment table data, refer to SIM46-13 (density adjustment (Normal text) in the FAX mode). [Operation] 1) Initial display ADJUST EXP. AUTO XX 3) Press [START] key. Scan is started (self print), and the LED of [START] key is turned off. ADJUST SCAN EXP. AUTO YY

("XX" is the exposure adjustment value of normal text stored on the FAX side.) 2) Enter a 2-digit value as the exposure adjustment value with [Numeric] key. ADJUST EXP. AUTO YY

4) Print is started (self print). ADJUST PRINT EXP. AUTO YY

("YY" is the entered exposure adjustment value.)

After completion of printing, returns to 2) display.

AR-FX13 SIMULATION 4 - 2

Main code 46

Sub code 13

Contents FAX mode density adjustment (Normal text)

Details of function/operation [Function] Scan is started with the exposure adjustment value entered with [START] key, and the stored data of the selected mode on the FAX side is rewritten into the input value. Density adjustment value data table Mode STD (Normal text) Fine (Fine text) Sfine (Super fine) Photo off on off on off Exposure adjustment value

When initializing each data: 50 [Operation] 1) Initial display ADJUST EXP. STD XX 3) Press [START] key. Scan is started (self print), and the LED of [START] key is turned off. ADJUST SCAN EXP. STD YY

("XX" is the corresponding exposure adjustment value of normal text mode stored on the FAX side.) 2) Enter a 2-digit value as the exposure adjustment value with [Numeric] key. ADJUST EXP. STD YY

4) Print is started (self print). ADJUST PRINT EXP. STD YY

After completion of printing, returns to 2) display.

("YY" is the entered exposure adjustment value.) 14 FAX mode density adjustment (Fine text) [Function] When [START] key is pressed, scan is started with the entered exposure adjustment value and the data of the selected mode on the FAX side is changed to the entered value. For the density adjustment value table data, refer to SIM46-13 (FAX mode density adjustment (Normal text).) [Operation] 1) Initial display ADJUST EXP. FINE XX 3) Press [START] key. Scan start (self print) ADJUST SCAN EXP. FINE YY

("XX" is the corresponding exposure adjustment value of the fine text mode stored on the FAX side.) 2) Enter a 2-digit value as the exposure adjustment value with [Numeric] key. ADJUST EXP. FINE YY

4) Print start (self print) ADJUST PRINT EXP. AUTO YY

After completion of printing, returns to 2) display.

("YY" is the entered exposure adjustment value.) 15 FAX mode density adjustment (Super fine) [Function] When [START] key is pressed, scan is started with the entered exposure adjustment value and the data of the selected mode on the FAX side is changed to the entered value. For the density adjustment value table data, refer to SIM46-13 (FAX mode density adjustment (Normal text).) [Operation] 1) Initial display ADJUST EXP. S-FINE XX 3) Press [START] key. Scan start (self print) ADJUST SCAN EXP. S-FINE YY

("XX" is the corresponding exposure adjustment value of the super fine mode stored on the FAX side.) 2) Enter a 2-digit value as the exposure adjustment value with [Numeric] key. ADJUST EXP. S-FINE YY

4) Print start (self print) ADJUST PRINT EXP. S-FINE YY

After completion of printing, returns to 2) display.

("YY" is the entered exposure adjustment value.) AR-FX13 SIMULATION 4 - 3

Main code 46

Sub code 39

Contents FAX mode sharpness adjustment

Details of function/operation [Function] When [START] key is pressed, scan is started with the entered sharpness adjustment value, and the data of the selected mode stored on the FAX side is changed to the entered value. Sharpness adjustment value data table 1: 2: 3: 4: 5: Mode STD FINE S-FINE FINE/PHOTO S-FINE/PHOTO Sharpness adjustment value

When initializing each data: 1 [Operation] 1) Initial display SHARPNESS SETTING PRESS , 2) [ ][ ] key or after 2sec Every time when [ ] key is pressed, the second line is changed in the sequence of No. 1 2 3 4 5 1. When [ ] key is pressed, the sequence is reversed. SHARPNESS SET (1-5) 1:STD 3) Select the arrow key 1-5, and the LED of [START] key is lighted. SHARPNESS SETTING ZZZZ(0-2) X ("ZZZZ" is the mode selected among STD, FINE, S-FINE, FINE/PHOTO, and S-FINE/ PHOTO.) ("X" is the corresponding sharpness adjustment value of the selected mode stored on the FAX side.) [Clear] key: Returns to 2) display. 66 01 FAX soft SW setting [Function] Use to check the FAX soft SW setting. Every time when the key is pressed, the bit on the first line is switched 0 and 1. [Operation] 1) Initial display ENTER FAX SOFT SW. # (3 DIGITS) SW.___ [Clear] key: Returns to the main-sub code input display. 2) Enter a 3-digit value of soft SW No. (To enter the fourth digit, shift to the left.), and the press [ENTER]/[OK] key. No.### CHANGE? xxxxxxxx 1:YES 2:NO 3) Select 1 No.### xxxxxxxx USE # KEY 12345678 4) Change with 1-8 of [Numeric] key and the press [ENTER]/[OK] key. No.### STORED? xxxxxxxx 1:YES 2:NO 4) Enter a one-digit value (0-2) as the sharpness adjustment value with [Numeric] key. SHARPNESS SETTING ZZZZ(0-2) Y ("Y" is the entered sharpness adjustment value.) [Clear] key: Returns to 2) display. 5) Press [START] key. Scan start (self print) SHARPNESS SETTING SCAN Y 6) Print start (self print) SHARPNESS SETTING PRINT Y After completion of printing, returns to 4) display.

"xxxxxxxx" is the set content. Select 2: Returns to the soft SW No. entry display. 5) Select 1 STORED After 2sec, returns to "1) Initial display".

"xxxxxxxx" is the set content. Select 2: Returns to the soft SW No. entry display.

02

FAX soft SW initializing (excluding the adjustment values)

[Function] Use to initializing FAX soft SW. [Operation] 1) Initial display INITIALIZED After 2sec, main code and sub code input display. AR-FX13 SIMULATION 4 - 4

Main code 66

Sub code 03

Contents FAX PWB memory check

Details of function/operation [Function] Use to check the FAX PWB memory. [Operation] 1) Initial display SELECT CHECK MEMORY PRESS , 2) [ ][ ] key or after 2sec ] key is pressed, the second line is changed in the sequence of No. 1 2

Every time when [ 3 1. When [

] key is pressed, the sequence is reversed. SELECT MEMORY (1-3) 2:SRAM SELECT MEMORY (1-3) 3:FLASH

SELECT MEMORY (1-3) 1:DRAM

[Clear] key: Returns to the main-sub code input display. 3) [ENTER]/[OK] key CHECKING MEMORY 4) After completion of check When the result is OK MEMORY CHECK RESULT OK In case of sum check error MEMORY CHECK RESULT XXXXXXXX SUM NG In case of address bus check error MEMORY CHECK RESULT XXXXXXXX A-BUS NG In case of data check error MEMORY CHECK RESULT XXXXXXXX DATA NG In case of data bus check error MEMORY CHECK RESULT XXXXXXXX D-BUS NG In case of erase check error MEMORY CHECK RESULT XXXXXXXX ERASE NG

[Clear] key: Returns to "1) Initial display". 04 Signal send mode (Max. value) [Function] Use to set the signal send mode (Max. value). Facsimile simulation design specifications. 1 2 3 4 5 6 7 8 9 10 11 12 NO SIGNAL 33600bps(V34) 31200bps(V34) 28800bps(V34) 26400bps(V34) 24000bps(V34) 21600bps(V34) 19200bps(V34) 16800bps(V34) 14400bps(V34) 12000bps(V34) 9600bps(V34) 13 14 15 16 17 18 19 20 21 22 23 24 7200bps(V34) 4800bps(V34) 2400bps(V34) 14400bps(V33) 12000bps(V33) 14400bps(V17) 12000bps(V17) 9600bps(V17) 7200bps(V17) 9600bps(V29) 7200bps(V29) 4800bps(V27ter) 25 26 27 28 29 30 31 32 33 34 35 2400bps(V27ter) 300bps(FLAG) 2100Hz(CED) 1100Hz(CNG) 300bps(V21) 2100Hz(ANSam) DUMMY RING NO VOICE ANSWER NO RING BACK TONE LINE OFF HOOK LINE ON HOOK

[Operation] 1) Initial display SELECT OUTPUT SIGNAL (2 DIGITS) No.___ 2) 2-digit (1-35) with [Numeric] key / [ Pressing [ No. (1-35) 1:NO SIGNAL ] key or [ ..... ][ ] key / 2sec after

] key reverses the sequence. No. (1-35) 35:LINE ON HOOK

[Clear] key: Returns to the main-sub code input display. 3) [ENTER]/[OK] key Send after setting OUTPUTING SIGNAL MAX PRESS CLEAR TO STOP [Clear] key: Returns to "1) Initial display".

AR-FX13 SIMULATION 4 - 5

Main code 66

Sub code 05

Contents Signal send mode (Soft SW set value)

Details of function/operation [Function] Use to set the signal send mode (Soft SW set value). Facsimile simulation design specifications. 1 2 3 4 5 6 7 8 9 10 11 12 NO SIGNAL 33600bps(V34) 31200bps(V34) 28800bps(V34) 26400bps(V34) 24000bps(V34) 21600bps(V34) 19200bps(V34) 16800bps(V34) 14400bps(V34) 12000bps(V34) 9600bps(V34) 13 14 15 16 17 18 19 20 21 22 23 24 7200bps(V34) 4800bps(V34) 2400bps(V34) 14400bps(V33) 12000bps(V33) 14400bps(V17) 12000bps(V17) 9600bps(V17) 7200bps(V17) 9600bps(V29) 7200bps(V29) 4800bps(V27ter) 25 26 27 28 29 30 31 32 33 34 35 2400bps(V27ter) 300bps(FLAG) 2100Hz(CED) 1100Hz(CNG) 300bps(V21) 2100Hz(ANSam) DUMMY RING NO VOICE ANSWER NO RING BACK TONE LINE OFF HOOK LINE ON HOOK

[Operation] 1) Initial display SELECT OUTPUT SIGNAL (2 DIGITS) No.___ 2) 2-digit (1-35) with [Numeric] key / [ Pressing [ No. (1-35) 1:NO SIGNAL ] key or [ ..... ][ ] key / 2sec after ] key reverses the sequence. No. (1-35) 35:LINE ON HOOK

[Clear] key: Returns to the main-sub code input display. 3) [ENTER]/[OK] key: Send after setting OUTPUTING SIGNAL SSW PRESS CLEAR TO STOP [Clear] key: Returns to "1) Initial display". 07 Image memory content print [Function] Use to print the image memory content. [Operation] When print is allowed PRINT STORED After completion of printing, main code and sub code input display. 10 Image memory content clear When there is no print data NO DATA After 2 sec, FAX control is terminated. When print is inhibited CAN NOT PRINT After 2 sec, main code and sub code input display.

[Function] Use to clear the image memory content. [Operation] When there are some print data CLEAR IMAGE MEMORY After completion of memory clear, the buzzer sounds. CLEARED PLEASE POWER OFF Remains unchanged until the power is turned off. When there are no print data CLEAR IMAGE MEMORY After completion of memory clear CLEARED After 2sec, main code and sub code input display.

AR-FX13 SIMULATION 4 - 6

Main code 66

Sub code 11

Contents 300bps signal send (Max. value)

Details of function/operation [Function] Use to set the 300bps signal send (Max. value). 1: 2: 3: 4: 5: 6: NO SIGNAL 11111 11110 00000 010101 00001

[Operation] 1) Initial display SELECT SIGNAL PRESS , 2) [ ][ ] key or after 2sec Every time when [ ] key is pressed, the second line is changed in the sequence of No. 1 2 3 4 5 6 1. When [ ] key is pressed, the sequence is reversed. ..... SELECT SIGNAL (1-6) 6:00001 SELECT SIGNAL (1-6) 1:NO SIGNAL 3) [ENTER]/[OK] key OUTPUTING SIGNAL MAX PRESS CLEAR TO STOP [Clear] key: Returns to "1) Initial display". 12 300bps signal send (Soft SW set value) [Function] Use to set the 300bps signal send (Soft SW set value). 1: 2: 3: 4: 5: 6: NO SIGNAL 11111 11110 00000 010101 00001

[Clear] key: Returns to the main-sub code input display.

[Operation] 1) Initial display SELECT SIGNAL PRESS , 2) [ ][ ] key or after 2sec Every time when [ ] key is pressed, the second line is changed in the sequence of No. 1 2 3 4 5 6 1. When [ ] key is pressed, the sequence is reversed. ..... SELECT SIGNAL (1-6) 6:00001 SELECT SIGNAL (1-6) 1:NO SIGNAL 3) [ENTER]/[OK] key OUTPUTING SIGNAL SSW PRESS CLEAR TO STOP [Clear] key: Returns to "1) Initial display".

[Clear] key: Returns to the main-sub code input display.

AR-FX13 SIMULATION 4 - 7

Main code 66

Sub code 13

Contents Dial test [Function] Use to the dial test. [Operation] Dial test (PULSE) 1) Initial display SELECT SIGNAL 1:PULSE 2:DTMF

Details of function/operation

Dial test (DTMF) 1) Initial display SELECT SIGNAL 1:PULSE 2:DTMF [Clear] key: Returns to the main-sub code input display. 2) __ Select 2 SELECT HIGH LEVEL 1:DEFAULT 2:SOFT SW. 3) Select 1 Select 2 __

[Clear] key: Returns to the main-sub code input display. 2) Select 1 INPUT MAKE TIME (0-15)

3) Enter the make time in 2 digits. INPUT DIAL # XXXX XXXX: Default After deleting with [Clear] key, input can be made. 4) [ENTER]/[OK] key SEND yyPPS xxms 1:YES 2:NO "yy" is the selected pulse 10 or 20. "xx" is the input value. Select 2: Returns to 2) display. 5) Select 1 Switched to 10/20PPS set with pulse selection inside. 6) After setting SENDING yyPPS xxms 7) After completion of sending TERMINATE ? 1:YES 2:NO Select 2: Returns to 4) display. 8) Select 1 TERMINATED After 2sec, returns to "1) Initial display". 4) Select 1 INPUT DIAL # XXXX XXXX: Default

INPUT VALUE (0-15)

SELECT LOW LEVEL 1:DEFAULT 2:SOFT SW. Select 2 __

INPUT VALUE (0-15)

After deleting with [Clear] key, input can be made. 4) [ENTER]/[OK] key H:xx 1:YES 2:NO L:yy

"xx" indicates HI, and "yy" indicates Low Soft SW. Select 2: Returns to 4) display. 5) Select 1 HI/LO is selected with the signal level inside. 6) After setting the signal send level SENDING DTMF 7) After completion of sending TERMINATE ? 1:YES 2:NO Select 2: Returns to 4) display. 8) Select 1 TERMINATED After 2sec, returns to "1) Initial display".

17

DTMF signal send (Max. value)

[Function] Use to set the DTMF signal send (Max. value). [Operation] 1) Initial display INPUT DIAL # [Clear] key: Returns to the main-sub code input display. 2) [Numeric] key input The content selected with signal send level selection is set inside. 3) Communication is started after setting the signal send level. SENDING SIGNAL MAX PRESS CLEAR TO STOP [Clear] key: Returns to "1) Initial display".

AR-FX13 SIMULATION 4 - 8

Main code 66

Sub code 18

Contents DTMF signal send (Soft SW set value)

Details of function/operation [Function] Use to set the DTMF signal send (Soft SW set value). [Operation] 1) Initial display INPUT DIAL # 3) Communication is started after setting the signal send level. SENDING SIGNAL SSW PRESS CLEAR TO STOP

[Clear] key: Returns to the main-sub code input display. [Clear] key: Returns to "1) Initial display". 2) [Numeric] key input The content selected with signal send level selection is set inside. 21 FAX information print [Function] Use to print the FAX information. [Operation] 1) Initial display SELECT REPORT (1-3) PRESS , 2) [ ][ ] key or after 2sec ] key is pressed, the second line is changed in the sequence of 1 2 3

Every time when [ 1. When [

] key is pressed, the sequence is reversed. SELECT REPORT (1-3) 2:SOFT SW. LIST SELECT REPORT (1-3) 3:PROTOCOL

SELECT REPORT (1-3) 1:USER SW. LIST 3) [ENTER]/[OK] key When print is allowed PRINT STORED After completion of printing, main code and sub code input display. 24 FAST SRAM clear [Function] Use to clear the FAST SRAM. [Operation] 1) Initial display CLEAR FAST SRAM

[Clear] key: Returns to the main-sub code input display. When print is inhibited CAN NOT PRINT After 2sec, FAX control is terminated.

2) After completion of clearing CLEARED After 2sec, main code and sub code input display.

30

TEL/LIU status change check

[Function] Use to check the TEL/LIU status change. [Operation] 1) Initial display HS2 :xxx RHS :xxx HS1 :xxx EXHS:xxx The display is switched every 2sec. CHECKING PRESS CLEAR TO STOP [Clear] key: Returns to the main-sub code input display.

AR-FX13 SIMULATION 4 - 9

Main code 66

Sub code 33

Contents Signal detection check [Function] Use to check the signal detection. [Operation] 1) Initial display CHECKING NONE PRESS CLEAR TO STOP

Details of function/operation

When a signal is detected, the display is changed from NONE to the following. CI/CNG/CED/BT/DT/Flag/SDT/DTMF [Clear] key: Returns to the main-sub code input display. 34 Communication time measurement [Function] Use to measurement the communication time. [Operation] 1) Initial display COMM. TIME xx:xx:xx:xxx msec "xx:xx:xx:xxx" indicates o'clock, minute, second, millisecond. [Clear] key: Returns to the main-sub code input display. 37 Speaker sound volume setting [Function] Use to set the speaker sound volume. 1: 2: 3: 4: NO SOUND LOW MID HIGH

[Operation] 1) Initial display SELECT SPEEKER VOL. PRESS , 2) [ ][ ] key or after 2sec ] key is pressed, the second line is changed in the sequence of 1 2 3 Every time when [ 4 1. When [ SELECT (1-4) 1:NO SOUND 3) [ENTER]/[OK] key STORED xxx xxx: Set content After 2sec, main code and sub code input display.

] key is pressed, the sequence is reversed. SELECT (1-4) 2:LOW .....

[Clear] key: Returns to the main-sub code input display.

AR-FX13 SIMULATION 4 - 10

Main code 66

Sub code 38

Contents Time setting/check [Function] Use to check the time setting. [Operation] 1) Initial display SELECT TO SET 1:DATE 2:TIME

Details of function/operation

[Clear] key: Returns to the main-sub code input display. 2) Select 1 xxxx.xx.xx(xxx) CHANGE? 1:YES 2:NO "xxxx.xx.xx(xxx)" is the current value. (No revision of display) 3) Select 1 INPUT YEAR (4 DIGITS)____.__.__ Select 2: Returns to "1) Initial display". 4) Enter the year in 4 digits. INPUT MONTH (1-12) 1998.__.__ 5) Enter the month in 2 digits. INPUT DAY (1-31) 1998.01.__ 6) Enter the day in 2 digits. xxxx.xx.xx(xxx) STORED? 1:YES 2:NO "xxxx.xx.xx(xxx) is the entered value. Select 2: Returns to "1) Initial display". 7) Select 1 STORED After 2sec, returns to "1) Initial display". After 2sec, returns to "1) Initial display". 2) Select 2 xx:xx CHANGE? 1:YES 2:NO

"xx:xx" is the current value. 3) Select 1 INPUT HOUR (0-24) __:__

Select 2: Returns to "1) Initial display". 4) Enter o'clock in 2 digits. INPUT MINUTE (00-59) 01:__

5) Enter minute in 2 digits. xx:xx STORED? 1:YES 2:NO

"xx:xx" is the current value. Select 2: Returns to "1) Initial display". 6) Select 1 STORED

AR-FX13 SIMULATION 4 - 11

[5] FAX SOFT SWITCH


1. FAX soft switch setting change quick reference table
Large item Dialing Key operator Soft SW No. Usage None SW 5-5 8 When dialing disable/when error dialing User program SW 48-1, 2 When dialing disable None SW 51-1 5 When dialing disable in PBX (private branch exchange/Fax service, etc.) None SW 53-5 8 When dialing disable in PBX (private branch exchange/Fax service, etc.) None SW 39-4 8 When dialing disable in PBX (private branch exchange/Fax service, etc.) Pulse (10PPS) None SW 67-1 4 When pulse dialing disable Signal detection Busy tone detection None SW 7-3 When busy tone detection disable Busy tone detection None SW 51-7, 8 When busy tone error is detected Dial tone detection None SW 7-2 Redial In case of an error Resend interval User program SW 4-1 4 When send errors occur frequently (For the New Zealand models, tough it is set to 0, recall is performed in an interval of 1min.) In case of an error Number of times of resend User program SW 40-1 8 When busy Resend interval User program SW 4-5 8 Whey busy occurs frequently When busy Number of times of resend User program SW 41-1 8 Arrival (Call-in) When CI detection CI detection None SW 12-6, 7 No call-in disable CI signal OFF detection None SW 55-1 7 No call-in time External Setting of an external Yes/No None SW 47-2 When an external telephone is connected telephone telephone connected Remote switch Entry of a 2-digit number User program SW 2-5 8 When remote switch is erroneously number detected Remote switch Yes/No User program SW 8-5 When remote switch is erroneously setting detected Communication General Send level None SW 15-4 8 When the remote machine cannot receive signals in a proper level. JBIG mode None SW 17-4, 8 When an error occurs in the JBIG mode SG3 V34 mode function setup None SW 43-1 When SG3 communication error occurs frequently V34 symbol rate None SW 43-4 6 When SG3 communication error occurs frequently Transmission G3/SG3 DIS reception check None SW 6-8 When an error occurs in phase B Line equalizer None SW 59-5 8 Setting is made referring to the distance from the station when a communication trouble occurs. SG3 V34 send speed None SW 44-1 4 When an error occurs in the SG3 communication. Manual send V34 None SW 42-8 When an error occurs in the SG3 communication in FAX service, etc. G3 Modem send speed None SW 16-1 4 To specified/unspecified destination RTN reception error None SW 52-5 When judged as OK though RTN is received Reception G3/SG3 CSI transmission None SW 6-3 Maximum reception length None SW 7-6 When a document of 1m or longer is received SG3 V34 reception speed None SW 44-5 8 When fall-down occurs frequently in the SG3 communication G3 Countermeasure against None SW 6-4 When an error occurs in phase B in echo in reception reception Modem speed in reception None SW 16-5, 6 When the line quality is poor and a fall-back or an error occurs EYE-Q check only None SW 72-1 Change in the detection method of training error Reception print Paper selection Automatic reduction print User program SW 24-8 When reduction print is not made Index Index print setup User program SW 32-6 When an index is attached to the reception data Middle item Switch content Remote machine call Pause time disable Dial call signal DTMF-related item

AR-FX13 FAX SOFT SWITCH 5 - 1

2. Soft switch list


When outside the set range, the default value is automatically set. Never change the soft switch setup which are inhibited to use. : A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 Item Image quality priority selection Switch selection and contents of functions Bit No. Normal Fine Super fine 1 0 0 1 2 0 1 0 Initial value A B C D E F G 0 0 0 0 0 0 0 Normal 0 0 0 0 0 0 0 0 0 0 0 0 1: Manual reception 0: Automatic reception Automatic reception 1: Not protected 0: Protected Protected 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 5 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 Remark

S W 1

3 4

Inhibited to use Auto/Manual default setup

Send request protection Inhibited to use

S W 2

6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7

Inhibited to use

Remote selection number setup

Binary input Bit No. Set range

5 6 7 8 0 to 9

0 0 0 0 0 0 1 1 1 1 1 1

Refer to User program RESO.PRIORITY. When a value outside 0 the set range is set, the initial value is set. 0 Manual reception can be set only when 0 external telephone is connected. Refer to User program 0 SECURITY SELECTION. 0 0 0 0 0 0 0 0 Refer to User program 1 REMOTE RECEPTION #. 0 When a value outside the set range is set, 1 the initial value is set.

Density default setup

Bit No. Light Medium Dark

1 1 0 0

2 0 0 0

3 0 1 0

4 0 0 0

5 0 0 1

S W 3

Inhibited to use Size specification

1 2

Recall interval in communication error

Bit No. Centimeter size Conforms to the machine information. Inch size Conforms to the machine information. Binary input Bit No. Set range

7 8 0 0 0 1 1 0 1 1

0 When a value outside 0 the set range is set, Medium 1 the initial value is set. 0 0 1 When set to conformity to the 0 0 0 0 0 0 0 machine information, Conforms to the if machine information machine is uncertain, set to information. centimeter size. 1 1 1 1 1 1 1 Refer to User program RECALL INTERVAL (LINE ERROR). When a value outside the set range is set, the initial value is set. For the New Zealand models, tough it is set to 0, recall is performed in an interval of 1min. Refer to User program RECALL INTERVAL (BUSY). When a value outside the set range is set, the initial value is set.

0 0 1 0 0 0

0 0 1 0 0 0

0 0 1 0 0 1

0 0 1 0 0 1

0 0 1 0 0 1

0 0 1 0 0 1

1 2 3 4 1 to 15min 0: Recall immediately after cutting the line 1min

0 0 0 0 0 0 0

0 0 0 0 0 0 0

3 S W 4

0 0 0 0 0 0 0 4 5 6 7 8 Recall interval in busy Binary input Bit No. Set range

1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3min 1 1 1 1 1 1 1 1 1 1 1 1 1 1

5 6 7 8 1 to 15min

AR-FX13 FAX SOFT SWITCH 5 - 2

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 3 S W 5 Item Inhibited to use G3 send data accumulation wait time Bit No. 6sec 5sec 4sec 3sec Binary input Bit No. Set range 1: 1: 1: 1: Yes Yes Yes 2 times 3 0 0 1 1 4 0 1 0 1 Switch selection and contents of functions Initial value A B C D E F G 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6sec 0 0 0 0 0 0 0 0 0 1 0 1 1 1 0 0 1 0 1 1 1 0 0 1 0 1 1 1 0 0 1 0 1 1 1 0 0 1 0 1 1 1 0 0 1 0 1 1 1 0 When a value outside 0 the set range is set, 1 the initial value is set. 0 1 1 1 Remark

4 5 6 7 8 1 2 3 4 Pause time setup

5 6 7 8 1 to 15sec

2sec

5 6 S W 6 7

2 3 4 5

ECM CED signal send CSI transmission DIS reception confirmation in G3 send Inhibited to use EOL detection timer Countermeasure for echo in reception (CED tone send interval) Countermeasure for echo in transmission (After reception of DIS, hold time up to signal send is set.) Dial tone ON/OFF detection time lower limit (Intermittent detection) Dial tone detection Busy tone detection Dial tone monitoring time Dial tone ON/OFF detection time upper limit (Intermittent detection) Max. length of reception Destination display time when one-touch key is pressed

1: 25sec 1: 500ms

0: No Yes 0: No Yes 0: No Yes 0: Once in NFS reception, Once in NFS 2 time in DIS reception reception, 2 time 0 0 0 0 0 0 0 in DIS reception 0 0 0 0 0 0 0 0: 13sec 13sec 0 0 0 0 0 0 0 0: 75ms 500ms

1 1 1 1 1 1 1

1: 800ms

0: 500ms 500ms 0 0 0 0 0 0 0

1: 300ms

0: 100ms 100ms 0 0 0 0 0 0 0

1: Yes 1: Yes 1: 10sec 1: 400ms

0: No 0: No 0: 5sec 0: 700ms

Yes (A) 1 0 0 0 0 0 0 No (B/C/D/E/F/G) Yes 5sec 1 1 1 1 1 1 1 0 0 0 0 0 0 0

S W 7

700ms

0 0 0 0 0 0 0

6 7 8 1 S W 8

1: No limit Bit No. 2sec 4sec 6sec 1: Direct transmission

0: 1.5m 7 0 0 1 0: 8 0 1 0 Memory transmission

1.5m

0 0 0 0 0 0 0 0 0 0 0 0 0 0 When a value outside the set range is set, the initial value is set.

2sec 0 0 0 0 0 0 0

2 3 4

Memory transmission/ direct transmission default setup Proxy reception 1: Yes Inhibited to use Quick online send 1: Yes

Memory transmission 0: No 0: No Yes Yes

0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1

AR-FX13 FAX SOFT SWITCH 5 - 3

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 5 S W 8 Item Remote select function 1: Yes Switch selection and contents of functions 0: No Yes Binary input Bit No. Set range 1: Yes 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 0 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 When a value outside 0 the set range is set, 0 the initial value is set. 0 0 1 Initial value A B C D E F G Remark Refer to User program REMOTE RECEPTION SELECT. When a value outside the set range is set, the initial value is set.

6 7 8 1

Number of times of CNG detection Print of total communication time and total pages Inhibited to use Ringing volume pattern number

6 7 8 1 to 4 times 0: No

3 times

Yes

S W 9

2 3 4 5 6 7 8 1

Binary input Bit No. Set range

3 4 5 6 7 8 Pattern No. 1 to 35

7 (A/B) 1 (C/D/E/F/G)

2 S W 10

S W 11

3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3

Measurement of 1: Yes communication time (image) Senders 1: Inhibit telephone number registration Inhibited to use

0: No Yes 0: Allow Allow 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 1 0 0 0 1 0 0 0 0 0 0 0 0 0 1 1 0 1 0 0 0 1 0 0 0 0 0 0 0 0 0 1 1 0 1 0 0 0 1 0 0 0 0 0 0 0 0 0 1 1 0 1 0 0 0 1 0 0 0 0 0 0 0 0 0 1 1 0 1 0 0 0 1 0 0 0 0 0 0 0 0 0 1 1 0 1 0 0 When a value outside 0 the set range is set, 1 the initial value is set. 1 1 1 1 1 1 1

ECM byte/frame Inhibited to use Inhibited to use

1: 64 [bytes/frame]

0: 256 [bytes/frame]

Call time setup in automatic transmission (T0 timer setup) Inhibited to use CI detection

Binary input Bit No. Set range

S W 12

1 2 3 4 30 to 75sec 5sec unit N x 5 + 30sec 6 0 1 0 7 0 0 1

0 0 0 256 [bytes/frame] 0 0 0 0 0 0 1 1 0 1 0 0 0 45sec 1

1 1 1 1 1 1 1 0 0 0 0 0 0 0 When a value outside the set range is set, the initial value is set.

Bit No. 4 sine wave 3 sine wave 2 sine wave

0 0 0 0 0 0 0 4 sine wave 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Inhibited to use Inhibited to use Ringing volume Bit No. Silent Small Medium Large 3 0 0 1 1 4 0 1 0 1

S W 13

Refer to User program 1 1 1 1 1 1 1 RINGER VOLUME. Medium 0 0 0 0 0 0 0

AR-FX13 FAX SOFT SWITCH 5 - 4

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 5 S W 13 Item Speaker volume in DTMF send Switch selection and contents of functions Bit No. Not used Small Medium Large 5 0 0 1 1 6 0 1 0 1 Initial value A B C D E F G 1 1 1 1 1 1 1 Medium 0 0 0 0 0 0 0 1 1 0 1 0 1 0 0 0 0 1: 350ms 0: 250ms 250ms 1: 650ms 0: 750ms 0 0 0 0 0 0 0 1 1 0 1 0 1 0 0 0 0 1 1 0 1 0 1 0 0 0 0 1 1 0 1 0 1 0 0 0 0 1 1 0 1 0 1 0 0 0 0 1 1 0 1 0 1 0 0 0 0 1 1 0 1 0 1 0 0 0 0 Remark

6 7 8 1 2 3 4 5 6 7 8 1 Inhibited to use Inhibited to use

S W 14

S W 15

Busy tone detection time (Lower limit) Busy tone detection time (Upper limit) Busy tone detection time (Lower limit 2) Signal send level

1: 150ms

0: Follows SW15-1.

4 5 6 7 8 1

Binary input Bit No. Set range

4 5 6 7 8 0 (0dBm) to 26 (26dBm)

750ms (A/B/C/D/E) 0 0 650ms (F/G) Follows SW15-1. (A/B) 0 0 150ms (C/D/E/F/G) 0 0 12dBm (A/B/G) 1 1 11dBm 1 1 (C/D/E) 0 0 9dBm (F) 0 0

0 0 0 1 1

1 1 1 1 1 0 1 0 1 1 0 1 0 1 1 0 1 0 1 1 0 1 0 0 1 0 When a value outside 1 the set range is set, 1 the initial value is set. 0 0

Modem speed (V.33 mode or less)

3 S W 16

4 5 Modem speed in reception fixed

6 7 8 1 2 S W 17 3 4 Inhibited to use Inhibited to use MH fixed (Except for SG3) ECM MMR mode (Except for SG3) ECM JBIG mode (Except for SG3)

Bit No. V.27 2400bps V.29 9600bps V.27 4800bps V.29 7200bps V.33 14.4kbps V.33 12.0kbps V.17 9600bps V.17 12.0kbps V.17 7200bps V.17 14.4kbps Bit No. No fixing V.29-9600BPS V.27ter-4800BPS V.17-14400BPS

1 2 3 0 0 0 0 0 0 0 0 1 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 0 1 Others 5 6 0 0 0 1 1 0 1 1

4 0 1 0 1 0 0 1 0 1

1 1 1 1 1 1 1

0 0 0 0 0 0 0 V.17 14.4kbps 0 0 0 0 0 0 0

0 0 0 0 0 0 0

0 0 0 0 0 0 0 No fixing 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

1: Yes 1: Yes 1: Yes

0: No (depending on the other partys machine) 0: No 0: No

No Yes Yes

0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1

AR-FX13 FAX SOFT SWITCH 5 - 5

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 5 6 S W 17 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 Item Inhibited to use MH fixed (in SG3) 1: Yes ECM MMR mode (in SG3) ECM JBIG mode (in SG3) Inhibited to use 1: Yes 1: Yes Switch selection and contents of functions Initial value A B C D E F G 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 0 0 0 0 0 1 0 0 0 1: Yes 0: No No 1 1 0 1 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 1 0 0 0 Refer to User program AUTO LISTING. Remark

0: No (depending on the other partys machine) 0: No 0: No

No Yes Yes

S W 18

Inhibited to use

S W 19

Recording table automatic print Inhibited to use Line sound monitor range

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

S W 20

3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

Line monitor display Inhibited to use Receivable memory capacity Inhibited to use

Bit No. OFF Up to NSF signal send/ receive All 1: Yes

1 2 0 0 0 1 1 0 0: No

0 0 0 0 0 0 0 OFF 0 0 0 0 0 0 0

When a value outside the set range is set, the initial value is set.

No

0 0 0 0 0 0 0 0 0 0 0 0 0 0

1: 64Kbyte

0: 128Kbyte

128Kbyte

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0

S W 21

Interval between completion of communication and the next call

Binary input Bit No. Set range

1 2 3 4 5 6 7 8 0 to 255sec

Inhibited to use

S W 22

0 0 0 0 0 0 0 1sec (A/B) 6sec (C/D/E/F/G) 0 0 0 1 0 0 0 0 0 0 0 0

AR-FX13 FAX SOFT SWITCH 5 - 6

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 3 4 5 6 7 8 1 2 3 4 Item Inhibited to use Switch selection and contents of functions Initial value A 0 0 0 0 0 0 0 0 0 0 B 0 0 0 0 0 0 0 0 0 0 C 0 0 0 0 0 0 0 0 0 0 D 0 0 0 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 0 0 0 F 0 0 0 0 0 0 0 0 0 0 G 0 0 0 0 0 0 0 0 0 0 Remark

S W 23

Inhibited to use Specified number reception (ANTI JUNK FAX) Bit No. Not set. Receive inhibit 3 4 0 0 0 1

Not set.

S W 24

5 6

Inhibited to use Document output 1: Collective output after setup in reception completion of reception

Refer to Main menu ANTI JUNK FAX. When a value outside 0 0 0 0 0 0 0 the set range is set, the initial value is set. 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0: Output after reception of every page

7 8

Inhibited to use Automatic reduction print Automatic reduction rate setup Transmission end sound tone

Output after reception of every page (A/B) Collective output 0 0 1 1 1 1 1 after completion of reception (C/D/E/F/G) 0 0 0 0 0 0 0 Allow Refer to User program 1 1 1 1 1 1 1 AUTO RCV REDUCE. 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 When a value outside 0 0 0 0 0 0 0 the set range is set, the initial value is set. 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1000Hz 1 1 1 1 1 1 1 1sec 0 0 0 0 0 0 0 0 0 0 0 0 0 0 When a value outside the set range is set, the initial value is set.

1: Allow

0: Inhibit

S W 25

1 2 3 4 5 6 7 8 1 2 3

Binary input Bit No. Set range Bit No. 550Hz 1000Hz 1700Hz Bit No. 550Hz 1000Hz 1700Hz 1: Mute

1 2 3 4 0 to 15% 5 0 0 1 7 0 0 1 0: 6 0 1 0 8 0 1 0 1sec

10%

1000Hz

Reception end sound tone

Read completion sound Inhibited to use Speaker volume setup

S W 26

Bit No. Silent Small Medium Large

3 0 0 1 1

4 0 1 0 1

Small

5 6 7 8

Inhibited to use

Refer to User program 0 0 0 0 0 0 0 BEEPER VOLUME (send completion sound / receive completion sound / 1 1 1 1 1 1 1 scan completion sound / alarm sound) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

AR-FX13 FAX SOFT SWITCH 5 - 7

SW Data Item NO. No. 1 Inhibited to use 2 3 4 S 5 W 6 27 7 Recording paper tray selection 8

Switch selection and contents of functions

Initial value 0 1 1 1 1 0

Remark

Bit No. AUTO TRAY1 TRAY2

7 0 0 1

8 0 1 0

AUTO

S W 28

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1

Inhibited to use

Number of auto switch calls of Binary input manual reception auto reception Bit No. Set range

1 2 3 4 0 to 9 Not switched when 0.

0 time

S W 29

Refer to User program TRAY SELECTION. When a value outside 0 the set range is set, the initial value is set. 1 1 0 1 0 0 0 0 0 Refer to User program 0 # OF RINGS MANUAL RX. 0 When a value outside the set range is set, 0 the initial value is set. 0 0 Refer to User program 0 # OF RINGS AUTO RX. 1 When a value outside the set range is set, 0 the initial value is set. 0 0 1 0 1 0 0 1

Setup of number of times of call rings

Binary input Bit No. Set range

5 6 7 8 0 to 9 times

2 times

Report output when canceling Inhibited to use

1: Output

0: Not output

Not output

S W 30

Default data, sender print Inhibited to use Date/sender print position setup Inhibited to use Report output (in transmission)

1: ON 1: Inside of document

0: OFF 0: Outside of document

ON Outside of document

2 3 Report output (In broadcast and sequential send request)

4 S W 31

Report output (in reception)

6 7 Contents of send document are printed in memory send

Bit No. Print inhibited All print Only when transmission is failed. Bit No. Print inhibited All print Only the address to which transmission is failed Bit No. Print inhibited All print Only in error Bit No. Print inhibited All print Only the address to which transmission is failed

1 0 0 1 3 0 0 1

2 0 1 0 4 0 1 0

Only when transmission is failed.

Refer to User program 1 PRINT SELECTION. When a value outside the set range is set, 0 the initial value is set. Refer to User program 0 PRINT SELECTION. When a value outside the set range is set, the initial value is set. 1

All print

5 0 0 1 7 0 0 1

6 0 1 0 8 0 1 0

Refer to User program 0 PRINT SELECTION. Print inhibited When a value outside the set range is set, 0 the initial value is set. Refer to User program Only the address 1 PRINT SELECTION. When a value outside to which the set range is set, transmission is the initial value is set. failed 0

AR-FX13 FAX SOFT SWITCH 5 - 8

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 3 S W 32 4 5 6 7 8 1 2 3 4 5 6 7 8 1 Inhibited to use Index print setup Inhibited to use Page number print 1: Yes setup Inhibited to use 0: No Item Distinctive ringing (U.S.A., Canada, Australia, New Zealand) Switch selection and contents of functions Bit No. OFF Standard/ON Pattern 1 *1 Pattern 2 *1 Pattern 3 *1 Pattern 4 *1 Pattern 5 *1 1: Print 1 0 0 1 0 1 0 1 2 0 0 0 1 1 0 0 3 0 0 0 0 0 1 1 4 0 1 0 0 0 0 0 Initial value A B C D E F G 0 0 0 0 0 0 0 Remark

OFF

Refer to User program DISTINCTIVE RING. 0 0 0 0 0 0 0 When a value outside the set range is set, 0 0 0 0 0 0 0 the initial value is set. *1: For U.S.A., Canada only 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0: Not print

Not print

0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0

Refer to User program INDEX PRINT.

Yes

1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Refer to User program DUPLEX RCV.

S W 33

2 S W 34

3 4 5 6 7 8 1 2 3

Reception data 1: Yes duplex print Flash send wait Bit No. time (U.S.A., 0sec Canada, U.K., 0.5sec Netherlands, 1sec Luxembourg, 2sec Belgium, France, Australia, New Zealand: Inhibited to use) Inhibited to use Signal send level Max. Binary input Bit No. Set range 1: Yes

0: No 1 0 0 1 1 2 0 1 0 1

No

0 0 0 0 0 0 0

0 0 0 1 0 0 0 1sec 0 0 0 0 0 0 0

5 6 7 8 0 (0dBm) to 15 (15dBm) 0: No

8dBm

0 0 1 0 0 0

0 0 1 0 0 0

0 0 1 0 0 0

0 0 1 0 0 0

0 0 1 0 0 0

0 0 1 0 0 0

0 0 1 0 0 0

Cover function default setup Inhibited to use CI delete max. OFF time

No

0 0 0 0 0 0 0 1 1 1 1 1 1 1

S W 35

4 5 6 7 8 1 2 3 4 5 6 7 8 Answering machine call number setting CNG detection completion time

Bit No. 5sec 10sec 15sec 20sec Binary input Bit No. Set range Binary input Bit No. Set range

3 0 0 1 1

4 0 1 0 1

5sec (A/B/F/G) 10sec (C/D/E)

0 0 0 0 0 0 0

0 0 1 1 1 0 0 5 times (A/B) 6 times (C/D/E/F/G) 0 1 0 1 0 0 1 0 1 1 0 1 0 1 0 1 0 0 1 0 1 1 0 1 0 1 1 0 0 0 1 0 1 1 0 1 0 1 1 0 0 0 1 0 1 1 0 1 0 1 1 0 0 0 1 0 1 1 0 1 0 1 1 0 0 0 1 0 1 1 0 1 0 1 1 0 0 When a value outside 0 the set range is set, 1 the initial value is set. 0 1 1 0 1

5 6 7 8 0 to 15 times

1 2 3 4 5 6 7 8 1 to 255sec 45sec

S W 36

AR-FX13 FAX SOFT SWITCH 5 - 9

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 3 4 5 6 7 8 1 Item Inhibited to use Switch selection and contents of functions Initial value A 0 1 0 1 0 1 0 1 B 0 1 0 1 0 1 0 1 C 0 1 0 1 0 1 0 1 D 0 1 0 1 0 1 0 1 E 0 1 0 1 0 1 0 1 F 0 1 0 1 0 1 0 1 G 0 1 0 1 0 1 0 1 Remark

S W 37

Protocol monitor

2 3 S W 38 4 5

S W 39

7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2

Protocol monitor save Inhibited to use Flash send time (U.S.A., Canada, U.K., Netherlands, Luxembourg, Belgium, France, Australia, New Zealand: Inhibited to use) Transfer function 1: Inhibited to use Inhibited to use

Bit No. Not output Not output Output Output only in an error 1: Yes

1 0 0 1 1 0:

2 0 1 0 1 No

0 0 0 0 0 0 0 Not output 0 0 0 0 0 0 0 Yes 1 1 1 1 1 1 1 0 0 0 0 0 0 0

Bit No. 90ms 180ms 270ms 360ms

5 0 0 1 1

6 0 1 0 1

0 0 0 0 0 0 0 90ms 0 0 0 0 0 0 0

Allow

0: Inhibit

Allow

DTMF signal send Binary input time Bit No. Set range

1 0 0 0 1 0

4 5 6 7 8 60 to 310ms (U.S.A., Canada) 70 to 310ms (Europe, Australia, New Zealand) 10ms unit

1 0 0 0 0 0 When a value outside the set range is set, 1 1 1 1 1 1 1 the initial value is set.

1 0 0 0 1 0

1 0 0 0 1 0

1 0 0 0 1 0

1 0 0 0 1 0

1 0 0 0 0 0

110ms (A/B/F/G) 0 0 0 0 0 0 0 80ms (C/D/E) 1 1 0 0 0 1 1 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0

Number of times of recall in error

Binary input Bit No. Set range

S W 40

1 2 3 4 5 6 7 8 0 to 1 times (U.S.A., Canada, Australia, New Zealand) 0 to 5 times (Europe)

1 times

Refer to User program RECALL TIMES (LINE ERROR). When a value outside the set range is set, the initial value is set.

Number of times of recall in busy

Binary input Bit No. Set range

S W 41

1 2 3 4 5 6 7 8 0 to 14 times (U.S.A., Canada) 0 to 10 times (Europe) 0 to 9 times (Australia, New Zealand) 0: Allow 0: Inhibit

2 times

Refer to User program RECALL TIMES (BUSY). When a value outside the set range is set, the initial value is set.

S W 42

Direct send recall (U.S.A., Canada) FAX receive auto select by CNG detection

1: Inhibit 1: Allow

Allow Allow

0 0 0 0 0 0 0 Refer to User program 1 1 1 1 1 1 1 FAX SIGNAL AUTO RECEIVE.

AR-FX13 FAX SOFT SWITCH 5 - 10

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 3 Item Auto receive select in answering telephone connection mode Inhibited to use Switch selection and contents of functions 1: Allow 0: Inhibit Inhibit 0 0 0 0 0 0 0 Initial value A B C D E F G Remark Refer to Main menu AM MODE.

S W 42

4 5 6 7 8

1 0 0 0 0: OFF ON 0: OFF ON

1 0 0 0

1 0 0 0

1 0 0 0

1 0 0 0

1 0 0 0

1 0 0 0

1 2 3 4 S W 43

V.34 mode 1: ON function in manual communication V.34 mode 1: ON function Inhibited to use V.34 receive symbol speed mask Bit No. 2400 2743 2800 3000 3200 3429

1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1

5 6 7 8 1 2 3 4 5 6 7 8 1 2 Inhibited to use V.34 primary channel send speed V.34 primary channel receive speed

4 0 0 0 0 1 1

5 0 0 1 1 0 0

6 0 1 0 1 0 1

When a value outside 1 1 1 1 1 1 1 the set range is set, the initial value is set. 3429 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0

S W 44

Binary input Bit No. Send speed = 2400 (bps) x N Binary input Bit No. Receive speed = 2400 (bps) x N

1 2 3 4 When N = 0, 2400bps. When N = 15, 33600bps. 5 6 7 8 When N = 0, 2400bps. When N = 15, 33600bps. 0: 2 0 0 1 No 3 0 1 0

33600bps

33600bps

3 S W 45 4

FAST mode 1: Yes Bit No. Sequence of year/ month/day in LCD, Year/Month/Day report, and sender Month/Day/Year record Day/Month/Year Time display format Scan effective image area main scan right edge image loss (RSPF) Specification of print sequence in duplex print Specification of rotating direction duplex back surface print Priority in the day of week 1: am/pm

No

0: 24H

5 6 7 8 1

Binary input Bit No. Set range

5 6 7 8 0 to 360 dots 24 dots interval 0: Reception order (123456...) 0: No 180 degrees rotation

Refer to User program Month/Day/Year 0 0 1 1 1 1 1 DATE&TIME (A/B) FORMAT SET. Day/Month/Year When a value outside (C/D/E/F/G) 1 1 0 0 0 0 0 the set range is set, the initial value is set. Refer to User program am/pm (A/B) 1 1 0 0 0 0 0 DATE&TIME 24H (C/D/E/F/G) FORMAT SET. 0 0 0 0 0 0 0 1 1 1 1 1 1 1 96 dots 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Print order (214365...) 180 degrees rotation 1 1 1 1 1 1 1

1: Print order (214365...)

S W 46

1: 180 degrees rotation

1 1 1 1 1 1 1

1: Yes

0: No

No (A/B/C/F/G) Yes (D/E)

0 0 0 1 1 0 0

AR-FX13 FAX SOFT SWITCH 5 - 11

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 4 5 S W 46 Item Center No. in FAST mode Summer time Switch selection and contents of functions 1: Host-Tel-No. 1: Allow 0: Service-No. 0: Inhibit Initial value Service-No. Inhibit (A/B) Allow (C/D/E/F/G) A B C D E F G 0 0 0 0 0 0 0 Refer to Entry Mode 0 0 1 1 1 1 1 DAY LIGHT SAVING. Refer to User program 0 0 0 0 0 0 0 PBX SETTING MODE. 0 0 0 0 0 0 0 When a value outside the set range is set, 0 0 0 0 0 0 0 the initial value is set. 0 0 1 1 1 1 1 Yes 0: No Yes 1 1 1 1 1 1 1 0 0 0 1 0 0 Bit No. 10PPS TONE 1 2 0 0 1 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 Remark

6 7 8 1 2

S W 47

3 4 5 6 7 8 1 2

PBX setting (U.S.A., Canada, U.K., Netherlands, Luxembourg, Belgium, Australia, New Zealand: Inhibited to use) Inhibited to use External 1: telephone connection Inhibited to use

Bit No. Setting OFF Flash send ID send

6 0 1 1

7 0 0 1

8 0 1 0

Setting OFF

Tone/Pulse default setup

TONE

Refer to User program DIAL MODE. When a value outside 0 0 0 0 0 0 0 the set range is set, the initial value is set. 1 1 1 1 1 1 1 0 0 1 1 1 1 1 0 0 1 0 0 0 1 0 0 0 1 0 0 0 1 0 0 0 1 0 0 0 1 0 1 0 1 0

S W 48

Telephone line menu Inhibited to use Scan effective image area main scan left edge image loss (RSPF) Inhibited to use Speaker sound volume pattern number in DTMF send

1: Inhibit

0: Allow

Allow (A/B) Inhibit (C/D/E/F/G)

4 5 6 7 8 1 2 3 4 5 6 7 8 1

Binary input Bit No. Set range

5 6 7 8 0 to 360 dots 24 dots interval

96 dots

0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 When a value outside 0 the set range is set, 0 the initial value is set. 0 0 1 When SPEAKER key 1 1 1 1 1 1 1 is pressed, user setting can be made. 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1

S W 49

Binary input Bit No. Set range

3 4 5 6 7 8 Pattern No. 1 to 35

Line monitor volume

2 S W 50 3 4 5 6 7 8 1 2 3 4 5 Line monitor volume pattern number

Bit No. Silent Small Medium Large Binary input Bit No. Set range

1 0 0 1 1

2 0 1 0 1

Medium

0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 0 0 1 0 1 0 1 0 0 0 0 0 0 1 0 1 When a value outside the set range is set, the initial value is set.

3 4 5 6 7 8 Pattern No. 1 to 35

16

S W 51

DTMF send level Binary input (High group) setup Bit No. Set range

1 2 3 4 5 0 (0.0dBm) to 21 (21.0dBm) 1.0dBm unit

6dBm (A/B/C/D/E) 5dBm (F/G)

When a value outside the set range is set, the initial value is set.

AR-FX13 FAX SOFT SWITCH 5 - 12

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 6 S W 51 7 Item CED detection time Busy tone detection cycle Switch selection and contents of functions 1: 500ms Bit No. 2puls 4puls 6puls 10puls Bit No. 43dB 35dB 33dB 30dB 0: 1000ms 7 0 0 1 1 1 0 0 1 1 8 0 1 0 1 2 0 1 0 1 Initial value 1000ms A B C D E F G 0 0 0 0 0 0 0 Remark

0 0 0 0 0 0 0 2puls 0 0 0 0 0 0 0

8 1 Busy tone detection level

0 0 0 0 0 0 0 43dB 0 0 0 0 0 0 0 0 0 0 0 0 0 0

2 3 4 S W 52 5 6 7 8

Inhibited to use Super G3 disabled 1: Super G3 enabled in the last call-out of recall in case of an error Error process in 1: Not error RTN reception Inhibited to use V.34 control channel communication speed Maximum DTMF send level 1: 2400bps

0: Super G3 disabled Super G3 disabled 0: Error Error 0 0 0 0 0 0 0

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0: 1200bps 1200bps 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0

S W 53

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4

Binary input Bit No. Set range

1 2 3 4 0 (0.0dBm) to 15 (15.0dBm) 5 6 7 8 0 (2.0dBm) to 15 (+5.5dBm) 0.5dBm unit When set to 0: Low group = High group (2.0) dBm 1 2 3 4 0 to 240 lines 16 lines interval

0dBm

DTMF send level Binary input (difference Bit No. between high and Set range low level)

+2.0dBm (A/B/C/D/E/F) +1.5dBm (G)

0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1 1 0 0 0 0 1 0 1 1 0 1 1 1 0 0 1 0

S W 54

Scan effective image area sub scan lead edge image loss (RSPF) Scan effective image area sub scan rear edge image loss (RSPF) CI signal OFF detection enable time

Binary input Bit No. Set range

96 lines

Binary input Bit No. Set range

5 6 7 8 0 to 240 lines 16 lines interval

144 lines

Binary input Bit No. Set range

S W 55

1 2 3 4 5 6 7 0 to 1270ms 10ms unit

1200ms (A/B/C/D/E/F) 1100ms (G)

S W 56

Inhibited to use CI signal ON detection enable time Inhibited to use

Binary input Bit No. Set range

1 2 3 0 (155ms) to 7 (225ms) Step 10ms

155ms (A/B/C/D/E) 195ms (F/G)

0 0 0 0 0 0 0 0 0 0 0 0 0 0

AR-FX13 FAX SOFT SWITCH 5 - 13

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 5 S W 56 Item DT/BT detection frequency range Switch selection and contents of functions Bit No. Modem fixed (400Hz) 420Hz680Hz 360Hz440Hz 245Hz650Hz 5 0 0 1 1 6 0 1 0 1 Initial value 245Hz650Hz (A/B/C/D/E/F) 360Hz440Hz (G) A B C D E F G 1 1 1 1 1 1 1 Remark

6 7 8 1 2 Inhibited to use Inhibited to use Sharp machine mode Inhibited to use Reception gain adjustment

1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0

1: ON

0: OFF

ON

1 1 1 1 1 1 1 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0

S W 57

S W 58

3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3

Binary input Bit No. Set range

4 5 6 7 8 0 (+6.0dBm) to 24 (6.0dBm) Step 0.5dBm

0.0dBm

Dual wait inhibit time after CFR send

Binary input Bit No. Set range

1 2 3 4 0 to 3000ms 200ms unit 5 6 7 8 Settlement time = 50 (ms) x N + 200 (ms)

1600ms

FSK signal Binary input settlement time in Bit No. double wait Set range Inhibited to use Reception SED ON level Bit No. 43dB 38dB 33dB 48dB Bit No. 0dB 4dB 8dB 12dB Bit No. 0dB 4dB 8dB 12dB Binary input Bit No. Set range

550ms

4 S W 59 5 Transmission cable amplitude equalizer

6 7 Reception cable amplitude equalizer

8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

3 0 0 1 1 5 0 0 1 1 7 0 0 1 1

4 0 1 0 1 6 0 1 0 1 8 0 1 0 1

1 1 1 1 1 1 1 48dB 1 1 1 1 1 1 1

0dB (A/B/C/D/E) 4dB (F/G)

0 0 0 0 0 0 0

0 0 0 0 0 1 1

0 0 0 0 0 0 0 0dB 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

S W 60

Scan effective image area sub scan lead edge image loss (RSPF back surface) Scan effective Binary input image area sub Bit No. scan rear edge Set range image loss (RSPF back surface) Inhibited to use

1 2 3 4 0 to 240 lines 16 lines interval

96 lines

5 6 7 8 0 to 240 lines 16 lines interval

144 lines

S W 61

AR-FX13 FAX SOFT SWITCH 5 - 14

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 3 4 S W 62 Item Inhibited to use Switch selection and contents of functions Initial value A 0 0 0 B 0 0 0 C 0 0 0 D 0 0 0 E 0 0 0 F 0 0 0 G 0 0 0 Remark

V.8 mode ANSam signal send time

5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Inhibited to use

Bit No. 3sec 4sec 5sec 6sec

4 0 0 1 1

5 0 1 0 1

0 0 0 0 0 0 0 4sec 1 1 1 1 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0

Inhibited to use

S W 63

Inhibited to use

S W 64

Inhibited to use

S W 65

Inhibited to use

S W 66

Make time (10PPS) setup

Binary input Bit No. Set range

S W 67

1 2 3 4 26 to 41ms by increment of 1ms

40ms (A/B) 33ms (C/E) 41ms (D) 31ms (F) 34ms (G)

0 0 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Inhibited to use

AR-FX13 FAX SOFT SWITCH 5 - 15

SW Data Item NO. No. 1 Line open delay time in dial test

Switch selection and contents of functions Bit No. 2sec 3sec 4sec 5sec 1 0 0 1 1 2 0 1 0 1

Initial value

Remark

0 2sec 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 1 0 0

2 S W 68 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 S W 70 Inhibited to use T1 timer setup

Binary input Bit No. Set range

5 6 7 8 30 to 105sec 5sec interval

40sec

Inhibited to use

S W 69

Inhibited to use

Reception waiting time between frames Preamble send time of 300bps

1: 4.4sec Bit No. 0.5sec 1.0sec 1.5sec 2.0sec Bit No. 3 times 6 times 9 times 12 times

0: 3.4sec 5 0 0 1 1 7 0 0 1 1 6 0 1 0 1 8 0 1 0 1

3.4sec

0 1.0sec 1

6 7 RCP send times

0 3 times 0 0 0 0 0 1 1 0 0

8 1 2 3 4 5 6 7 8 1 2 3 S W 72 4 5 6 7 8 RTC EOL send times Inhibited to use CNG send start Inhibited to use

S W 71

EYE-Q check ERR frame reception operation Waiting time for CED/ANSam send start

1: EYE-Q check only 1: Continues process. Bit No. 2.25sec 3sec 4sec 1: 6 times Bit No. 0.5sec 1.0sec 1.5sec

0: 0 reception & EYE-Q check 0: Not continue process. (Error) 3 4 0 0 0 1 1 0 0: 7 times 7 0 0 1 8 0 1 0

0 reception & EYE-Q check Not continue process. (Error)

0 0 0 When a value outside the set range is set, the initial value is set.

2.25sec 0 6 times 1 0 0 0.5sec 0

When a value outside the set range is set, the initial value is set.

AR-FX13 FAX SOFT SWITCH 5 - 16

SW Data NO. No. 1 2 3 S 4 W 5 73 6 7 8 1 2 3 S 4 W 5 74 6 7 8 1 2 3 S W 75

Item Inhibited to use

Switch selection and contents of functions

Initial value 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 0

Remark

Print effective image area sub scan Binary input lead edge void Bit No. Set range Inhibited to use

1 2 3 4 0 to 240 lines 16 lines interval (600dpi)

32 lines

Manual calibration setting when 1: ON sending Manual calibration setting when a 1: ON signal arrives Communication end sound (Buzzer Bit No. sound length) setting 3sec 1sec Silent

0: OFF 0: OFF 3 0 0 1 4 0 1 0

OFF OFF

3sec

5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

Print effective image area main scan void

Binary input Bit No. Set range

5 6 7 8 0 to 240 dots 16 dots interval 0: +

48 dots

Communication error 0 sound is generated even in silent setup Refer to User program BEEP LENGTH. 0 When a value outside the set range is set, the initial value is set. 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

S W 76

Scan magnification ratio adjustment 1: (main scan) flag Scan magnification ratio adjustment Binary input (RSPF main scan) Bit No. Set range

2 3 4 5 6 7 8 0 to 12.7% 0.1% interval

0%

S W 77

Scan magnification ratio adjustment 1: (sub scan) flag Scan magnification ratio adjustment Binary input (RSPF sub scan) Bit No. Set range

0: +

2 3 4 5 6 7 8 0 to 12.7% 0.1% interval

0%

AR-FX13 FAX SOFT SWITCH 5 - 17

SW Data Item NO. No. 1 Print magnification ratio adjustment (main scan) flag 2 Print magnification S 3 ratio adjustment W 4 (main scan) 78 5 6 7 8 1 Print magnification ratio adjustment (sub scan) flag 2 Print magnification S 3 ratio adjustment W 4 (sub scan) 79 5 6 7 8 1 Destination information 2 3 4 S W 80 5 6 7

Switch selection and contents of functions 1: 0: +

Initial value + 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 1 0 0 0 1 1 0 1 0 0 1 0 1 1 1 1 0 8 1 1 0 0 1 1 0 1 0 0 0 1 0 1 1 0 0

Remark

Binary input Bit No. Set range

2 3 4 5 6 7 8 0 to 12.7% 0.1% interval

0%

1:

0: + +

Binary input Bit No. Set range

2 3 4 5 6 7 8 0 to 12.7% 0.1% interval

0%

Binary input Bit No.

1 2 3 4 5 6 7 8 U.S.A. (10110101) Canada (00100000) U.K. (10110100) Germany (00000100) France (00111101) Sweden (10100101) Spain (10100000) Italy (01011001) Switzerland (10100110) Finland (00111100) Denmark (00110001) Norway (10000010) Netherlands (01111011) Luxembourg (01101001) Belgium (00001111) Australia (00001001) New Zealand (01111110)

U.S.A. Canada U.K. Germany France Sweden Spain Italy Switzerland Finland Denmark Norway Netherlands Luxembourg Belgium Australia New Zealand

1 2 3 4 S W 81 5 6 7

Language information

Binary input Bit No. 0: Japanese 1: American English 2: English 3: French 4: German 5: Italian 6: Dutch 7: Swedish 8: Spanish

1 2 3 4 5 6 7 8 10: Turkish 11: Greek 12: Polish 13: Hungarian 14: Czech 15: Russian 16: Finnish 17: Norwegian 18: Danish 19: Chinese

1 1 0 1 0 0 1 1 0 1 0 0 1 0 0 0 0 0 1 U.S.A.: 1 0 Canada: 1 0 U.K.: 2 0 Germany: 4 0 France: 3 0 Sweden: 7 0 Spain: 8 0 Italy: 5 0 Switzerland: 4 0 Finland: 16 0 Denmark: 18 0 Norway: 17 0 Netherlands: 6 0 Luxembourg: 3 0 Belgium: 3 0 Australia: 2 0 New Zealand: 2 0

2 0 0 0 0 0 0 0 1 0 0 0 0 1 1 0 0 1 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

3 1 1 1 0 1 1 1 0 1 1 1 0 1 1 0 0 1 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

4 1 0 1 0 1 0 0 1 0 1 1 0 1 0 0 0 1 4 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 0 0

5 0 0 0 0 1 0 0 1 0 1 0 0 1 1 1 1 1 5 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0

6 1 0 1 1 1 1 0 0 1 1 0 0 0 0 1 0 1 6 0 0 0 1 0 1 0 1 1 0 0 0 1 0 0 0 0

7 0 0 0 0 0 0 0 0 1 0 0 1 1 0 1 0 1 7 0 0 1 0 1 1 0 0 0 0 1 0 1 1 1 1 1

Only command receive from the main unit can be rewritten.

AR-FX13 FAX SOFT SWITCH 5 - 18

: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Item OC scan size default setting Switch selection and contents of functions Bit No. LETTER LEGAL A4 1 0 0 0 2 0 0 0 3 0 1 1 4 1 0 1 Initial value A 0 0 0 B 0 0 0 C 0 0 1 D 0 0 1 E 0 0 1 F 0 0 1 Remark G 0 Refer to User program 0 OC SIZE 1 PRIORITY. When a value outside 1 the set range is set, the initial value is set. 0 0 0 1 0 0 0 When a value outside 0 the set range is set, 0 the initial value is set. 0 0 1 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0

LETTER (A/B) A4 (C/D/E/F/G)

S W 82

1 1 1 1 1 1 Inhibited to use 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 1 0 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 1 0 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 1 0 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 1 1 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0

Inhibited to use Speaker sound volume setting pattern number Binary input Bit No. Set range

S W 83

3 4 5 6 7 8 Pattern No. 1 to 35

Inhibited to use

S W 84

Inhibited to use

S W 85

Inhibited to use

S W 86

Inhibited to use

S W 87

Inhibited to use

S W 88

AR-FX13 FAX SOFT SWITCH 5 - 19

SW Data Item NO. No. 1 Inhibited to use 2 3 S 4 W 5 89 6 7 8 1 Inhibited to use 2 3 S 4 W 5 90 6 7 8 1 Symbol speed 3429 send enable in V.34 send 2 Symbol speed 3200 high carrier send enable in V.34 send 3 Symbol speed 3200 low carrier send enable in V.34 send 4 Symbol speed 3000 high carrier S send enable in V.34 send W 5 Symbol speed 3000 low carrier 91 send enable in V.34 send 6 Symbol speed 3429 enable in V.34 communicate 7 Symbol speed 2800 enable in V.34 communicate 8 Symbol speed 2743 enable in V.34 communicate 1 Inhibited to use 2 3 S 4 W 5 92 6 7 8 1 Inhibited to use 2 3 S 4 W 5 93 6 7 8 1 Inhibited to use 2 3 S 4 W 5 94 6 7 8

Switch selection and contents of functions

Initial value 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Remark

1: Enable 1: Enable 1: Enable 1: Enable 1: Enable 1: Enable 1: Enable 1: Enable

0: Disable 0: Disable 0: Disable 0: Disable 0: Disable 0: Disable 0: Disable 0: Disable

Enable Enable Enable Enable Enable Enable Enable Enable

1 1 1 1 1 1 1 1 0 1 0 1 1 0 0 0 0 1 0 1 1 0 0 0 0 1 0 1 1 0 0 0

AR-FX13 FAX SOFT SWITCH 5 - 20

SW Data NO. No. 1 2 3 S 4 W 5 95 6 7 8 1 2 3 S 4 W 5 96 6 7 8 1 2 3 S 4 W 5 97 6 7 8 1 2 3 S 4 W 5 98 6 7 8 1 2 3 S 4 W 5 99 6 7 8 1 2 3 S 4 W 5 100 6 7 8 1 2 3 S 4 W 5 101 6 7 8

Item Inhibited to use

Switch selection and contents of functions

Initial value 0 1 1 1 0 0 0 0 1 1 0 1 1 0 0 0 0 1 1 1 1 1 1 1 0 1 0 0 0 0 0 0 0 1 0 1 1 0 0 0 1 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1

Remark

Inhibited to use

Inhibited to use

Inhibited to use

Inhibited to use

Inhibited to use

Print effective image area sub scan Binary input lead edge void (Back surface) Bit No. Set range Print effective image area sub scan Binary input rear edge void (Back surface) Bit No. Set range

1 2 3 4 0 to 240 lines 16 lines interval (600dpi) 5 6 7 8 0 to 240 lines 16 lines interval (600dpi)

32 lines

48 lines

AR-FX13 FAX SOFT SWITCH 5 - 21

SW Data NO. No. 1 2 3 S 4 W 5 102 6 7 8 1 2 3 S 4 W 5 103 6 7 8 1 2 3 S 4 W 5 104 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1

Item Scan effective image area main scan left edge image loss (OC)

Switch selection and contents of functions Binary input Bit No. Set range Binary input Bit No. Set range

Initial value 0 1 0 0 0 1 0 0 0 1 1 0 1 0 0 1 0 1 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Remark

1 2 3 4 0 to 360 dots 24 dots interval 5 6 7 8 0 to 360 dots 24 dots interval 1 2 3 4 0 to 240 line 16 lines interval 5 6 7 8 0 to 240 line 16 lines interval 1 2 3 4 0 to 360 dots in the interval of 24 dots 5 6 7 8 0 to 360 dots in the interval of 24 dots 0: +

96 dots

Scan effective image area main scan right edge image loss (OC)

96 dots

Scan effective image area sub scan Binary input lead edge image loss (OC) Bit No. Set range Scan effective image area sub scan Binary input rear edge image loss (OC) Bit No. Set range Scan effective image area main scan left edge image loss (RSPF back surface) Scan effective image area main scan right edge image loss (RSPF back surface) Binary input Bit No. Set range Binary input Bit No. Set range

96 lines

144 lines

96 dots

96 dots

S W 105

Scan magnification ratio adjustment 1: (OC main scan) flag Scan magnification ratio adjustment Binary input (OC main scan) Bit No. Set range

2 3 4 5 6 7 8 0 to 12.7% 0.1% interval

0%

S W 106

Scan magnification ratio adjustment 1: (OC sub scan) flag Scan magnification ratio adjustment Binary input (OC sub scan) Bit No. Set range

0: +

2 3 4 5 6 7 8 0 to 12.7% 0.1% interval

0%

S W 107

2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

Scan magnification ratio adjustment 1: (RSPF back surface main scan) flag Scan magnification ratio adjustment Binary input (RSPF back surface main scan) Bit No. Set range

0: + +

2 3 4 5 6 7 8 0 to 12.7% 0.1% interval

0%

S W 108

Scan magnification ratio adjustment 1: (RSPF back surface sub scan) flag Scan magnification ratio adjustment Binary input (RSPF back surface sub scan) Bit No. Set range

0: +

2 3 4 5 6 7 8 0 to 12.7% 0.1% interval

0%

AR-FX13 FAX SOFT SWITCH 5 - 22

SW Data Item NO. No. 1 Print magnification ratio adjustment (Main scan back surface) flag 2 Print magnification ratio adjustment 3 (Main scan back surface) S 4 W 109 5 6 7 8 1 Print magnification ratio adjustment (Sub scan back surface) flag 2 Print magnification ratio adjustment 3 (Sub scan back surface) S W 110 4 5 6 7 8

Switch selection and contents of functions 1: Binary input Bit No. Set range 0: +

Initial value + 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Remark

2 3 4 5 6 7 8 0 to 12.7% 0.1% interval

0%

1: Binary input Bit No. Set range

0: +

2 3 4 5 6 7 8 0 to 12.7% 0.1% interval

0%

3. Soft switch descriptions


SW1 No.1, No.2 Image quality priority selection
Used to select the image quality setting when pressing [Clear All] key or during auto clear. Default: 0 0 (Normal)

SW4 No.1No.4 Recall interval in communication error


Used to set the interval for recall when communication is cut off by an error during memory send. (Including no response from the remote machine.) Setting is made in binary input. When set to 0, resend is mad immediately after completion of communication. However, the time interval set by SW21 "Interval between completion of communication and the next call" is valid. For the New Zealand models, tough it is set to 0, recall is performed in an interval of 1min. Default: 1min

SW1 No.3 Inhibited to use SW1 No.4 Auto/Manual default setup


Used to select Auto/Manual reception mode when turning on the power. Default: 0 (Automatic reception)

SW1 No.5 Send request protection


Used to set enable/disable of the confidential function (inhibit to send to erroneous destinations) in send request communication (remote send). The confidential function is performed by collating the number registered in this machine and the number registered in the remote machine. Sender number Send request allow number Default: 0 (Protected)

SW4 No.5No.8 Recall interval in busy


Used to set the interval for the next call when busy tone is detected in communication. Setting is made in binary input. Default: 3min

SW5 No.1, No2 Inhibited to use SW5 No.3, No.4 G3 send data accumulation wait time
Used to set wait time for accumulation of image data before sending image data directly. Default: 0 0 (6sec)

SW1 No.6No.8 Inhibited to use SW2 No.1No.4 Inhibited to use SW2 No.5No.8 Remote selection number setup
Used to set the number in binary input for remote switch receive from external telephone. However, "" in the remote switch number (X) is fixed. Default: 5

SW5 No.5No.8 Pause time setup


Used to set pause time when registering dials. Default: 2sec

SW6 No.1 ECM


Used to set YES/NO of error resend mode. When, however, SW43-1 (V.34 mode function) is OFF or when SW34-1 (V.34 mode function) is ON and send is made other than SG3, ECM setting of "NO" is valid. Since the ECM function is essential in V.34 mode and the remote machine may perform checking, when SW43-1 (V.34 mode function) is ON , this function is invalid in reception. Default: 1 (Yes)

SW3 No.1No.5 Density default setup


Used to set the density when pressing [Clear All] key or during auto clear. Default: 0 0 1 0 0 (Medium)

SW3 No.6 Inhibited to use SW3 No.7, No.8 Size specification


Used to set the size specification (AB series, inch series). Under setting of "Follow information from machine," when command information from the machine is uncertain, set this item to AB series. Default: 0 1 (Conforms to the machine information.)

SW6 No.2 CED signal send


Used to set YES/NO of CED signal send. This is valid only when SW52-7 (V.34 mode function) is OFF. This is because ANSam signal send is necessary for V.34 mode. When set to 1, CED signal send is performed. When set to 0, CED signal send is not performed. Default: 1 (Yes)

AR-FX13 FAX SOFT SWITCH 5 - 23

SW6 No.3 CSI transmission


Used to set YES/NO of CSI signal send. CSI signal includes the sender's number. Default: 1 (Yes)

SW8 No.1 Memory transmission/direct transmission default setup


Used to set whether memory send is ON or direct send is made (OFF) in the memory mode when pressing [Clear All] key or auto clear. Default: 0 (Memory transmission)

SW6 No.4 DIS reception confirmation in G3 send


Used to set YES/NO of DIS receive check in G3 mode send. When set to 1, DIS receive twice is checked. When set to 0, DIS once is checked when "NSF/DIS" is received; and DIS twice is checked when NSF is not received. Default: 0 (Once in NFS reception, 2 time in DIS reception)

SW8 No.2 Proxy reception


Used to set whether proxy reception is enabled or not. When set to 0, under the following error status, auto receive is not made in auto receive mode. Cover open Unit error (Toner, drum, developing-related errors) Recording paper JAM Document JAM Recording paper empty When set to 1, proxy reception is allowed. Default: 1 (Yes)

SW6 No.5 Inhibited to use SW6 No.6 EOL detection timer


Used to set detection timer of EOL (EndOfLine) in Phase C receive. Default: 0 (13sec)

SW6 No.7 Countermeasure for echo in reception (CED tone send interval)
Used to set the interval from CED send to FSK signal send of DIS. Default: 1 (500ms)

SW8 No.3 Inhibited to use SW8 No.4 Quick online send


Used to set whether quick online send function is enabled or not. When set to 0, send in memory mode ON is made in memory send. When set to 1, send in memory mode ON is made in quick online send. Default: 1 (Yes)

SW6 No.8 Countermeasure for echo in transmission (After reception of DIS, hold time up to signal send is set.)
Used to set the interval from DIS receive to DSC signal send. Default: 0 (500ms)

SW7 No.1 Dial tone ON/OFF detection time lower limit (Intermittent detection)
Used to set the minimum required time for detection of dial tone when the dial tone detection is set to "YES" and the kind of the dial tone detection is set to "Continuous." Default: 0 (100ms)

SW8 No.5 Remote select function


Used to set whether remote select function is enabled or not. Default: 1 (Yes)

SW8 No.6No.8 Number of times of CNG detection


Used to set the number of times of CNG detection for judgment of detection. Default: 3 times

SW7 No.2 Dial tone detection


Used to set whether dial tone is detected or not when calling out. When set to 1, dial tone is detected before calling out. When set to 0, dial tone is not detected and dialing is made after a certain time (3.5sec). Default: 1 (Yes) (U.S.A.) / 0 (No) (Other than U.S.A.)

SW9 No.1 Print of total communication time and total pages


Used to set whether the total communication time and total pages are printed on the communication report or not. When set to 1, the total communication time and total pages are printed on the communication report. When set to 0, the total communication time and total pages are not printed on the communication report. Default: 1 (Yes)

SW7 No.3 Busy tone detection


Used to set YES/NO of busy tone detection when calling out. Default: 1 (Yes)

SW7 No.4 Dial tone monitoring time


Used to set the monitoring time when detecting dial tone. Default: 0 (5sec)

SW9 No.2 Inhibited to use SW9 No.3No.8 Ringing volume pattern number
Used to set ringing volume pattern. Default: 7 (North America) / 1 (Other than North America)

SW7 No.5 Dial tone ON/OFF detection time upper limit (Intermittent detection)
Used to set the upper limit time for detection of dial tone when the dial tone detection is set to "YES" and the kind of the dial tone detection is set to "Intermittent." If a dial tone is detected for more than this upper limit time, it is not considered as a dial tone. Default: 0 (700ms)

SW10 No.1 Measurement of communication time (image)


Used to set YES/NO of measurement of communication time in phase C. It is the communication time in the latest phase C. (Unit: msec) Valid only in ECM communication. Default: 1 (Yes)

SW7 No.6 Max. length of reception


Used to set max. length of reception for long document. Default: 0 (1.5m)

SW10 No.2 Sender's telephone number registration


Used to set whether registered sender's telephone number can be changed or not. Default: 0 (Allow)

SW7 No.7, No.8 Destination display time when onetouch key is pressed
Used to set the time from displaying the destination to the next operation in one-touch dial or reduction dial. Default: 0 0 (2sec)

SW10 No.3No.5 Inhibited to use

AR-FX13 FAX SOFT SWITCH 5 - 24

SW10 No.6 ECM byte/frame


Used to set the frame size of error correction mode to be notified to the remote machine. Default: 0 (256 [bytes/frame])

SW17 No.2 MH fixed (Except for SG3)


Used to set whether coding capacity is fixed to MH or not in communication other than SG3. Default: 0 (No)

SW10 No.7, No.8 Inhibited to use SW11 No.1No.8 Inhibited to use SW12 No.1No.4 Call time setup in automatic transmission (T0 timer setup)
Used to set call time in automatic send. Setting is made by binary input of N into "(5sec x N) + 30sec" in the increment of 5sec. Default: 45sec

SW17 No.3 ECM MMR mode (Except for SG3)


Used to set whether MMR coding capacity is allowed or not in communication other than SG3. Default: 1 (Yes)

SW17 No.4 ECM JBIG mode (Except for SG3)


Used to set whether JBIG coding capacity is allowed or not in communication other than SG3. Default: 1 (Yes)

SW12 No.5 Inhibited to use SW12 No.6, No.7 CI detection


Used to set the detection frequency of CI signal (call signal). Default: 0 0 (4 sine wave)

SW17 No.5 Inhibited to use SW17 No.6 MH fixed (in SG3)


Used to set whether coding capacity is fixed to MH or not in SG3 communication. Default: 0 (No)

SW12 No.8 Inhibited to use SW13 No.1, No.2 Inhibited to use SW13 No.3, No.4 Ringing volume
Used to set the ringing volume when call-in. Default: 1 0 (Medium)

SW17 No.7 ECM MMR mode (in SG3)


Used to set whether MMR coding capacity is allowed or not in SG3 communication. Default: 1 (Yes)

SW17 No.8 ECM JBIG mode (in SG3)


Used to set whether JBIG coding capacity is allowed or not in SG3 communication. Default: 1 (Yes)

SW13 No.5, No.6 Speaker volume in DTMF send


Used to set the volume of transmission and DTMF sound from the speaker when SPEAKER key is pressed. Default: 1 0 (Medium)

SW18 No.1No.8 Inhibited to use SW19 No.1No.5 Inhibited to use SW19 No.6 Recording table automatic print
Used to set whether communication report is automatically outputted or not when the number of send/receive items which have not outputted yet on communication report reaches 50. When set to 1, they are automatically outputted. When set to 0, they are not outputted even the number of items reaches 50. Default: 0 (No)

SW13 No.7, No.8 Inhibited to use SW14 No.1No.8 Inhibited to use SW15 No.1 Busy tone detection time (Lower limit)
Used to set the lower limit of busy tone detection time (ON time). Default: 0 (250ms)

SW15 No.2 Busy tone detection time (Upper limit)


Used to set the upper limit of busy tone detection time (ON time). Default: 0 (750ms) (North America, Europe) / 1 (650ms) (Australia, New Zealand)

SW19 No.7, No.8 Inhibited to use SW20 No.1, No.2 Line sound monitor range
Used to set line sound monitor range when line sound monitor function is used. Default: 0 0 (OFF)

SW15 No.3 Busy tone detection time (Lower limit 2)


Used to set the lower limit 2 of busy tone detection time (ON time). Default: 0 (Follows SW15-1.) (North America) / 1 (150ms) (Other than North America)

SW15 No.4No.8 Signal send level


Used to set signal send level from MODEM. Setting is made in binary input in the increment of 1dBm. Default: 12dBm (North America, New Zealand) / 11dBm (Europe) / 9dBm (Australia)

SW20 No.3 Line monitor display


Used to set whether the communication speed and the receive level are displayed on LCD or not. Default: 0 (No)

SW20 No.4 Inhibited to use SW20 No.5 Receivable memory capacity


Used to set the remained memory capacity for allowing call-in. Default: 0 (128Kbyte)

SW16 No.1No.4 Modem speed (V.33 mode or less)


Used to set send start speed in communication other than V.34 mode. In an area of poor communication conditions, it is recommended to set communication speed to a lower level in advance. Default: 1 0 0 0 (V.17 14.4kbps)

SW20 No.6No.8 Inhibited to use SW21 No.1No.8 Interval between completion of communication and the next call
Used to set the interval between completion of communication and the next call. Setting is made in binary input. Default: 1sec (North America) / 6sec (Other than North America)

SW16 No.5, No.6 Modem speed in reception fixed


Used to set receive procedure start speed in a remote machine other than V.34. In setting of no fixing, the operations are the same as V.1714400BPS. Default: 0 0 (No fixing)

SW22 No.1No.8 Inhibited to use SW23 No.1No.8 Inhibited to use

SW16 No.7, No.8 Inhibited to use SW17 No.1 Inhibited to use

AR-FX13 FAX SOFT SWITCH 5 - 25

SW24 No.1, No.2 Inhibited to use SW24 No.3, No4 Specified number reception (ANTI JUNK FAX)
Used to set whether the FAX receive rejection function is made valid or not for registered FAX numbers. Default: 0 0 (Not set.)

SW29 No.5No.8 Setup of number of times of call rings


Used to set the number of calls before starting reception in auto receive mode. Setting is made in binary input. Default: 2 times

SW30 No.1 Report output when canceling


Used to set whether the user cancel report is outputted or not when send is canceled during document send. Default: 0 (Not output)

SW24 No.5 Inhibited to use SW24 No.6 Document output setup in reception
Used to set the document output procedure; whether all the received documents are collectively outputted after completion of reception or every page is outputted when it is received. Default: 0 (Output after reception of every page) (North America) / 1 (Collective output after completion of reception) (Other than North America)

SW30 No.2No.4 Inhibited to use SW30 No.5 Default data, sender print
Used to set whether sender information (registered in the sender registration), sending date, and time are printed on the upper edge of send document or not. Default: 1 (ON)

SW24 No.7 Inhibited to use SW24 No.8 Automatic reduction print


Used to set whether automatic reduction print is performed or not so that a document longer than the fixed size and smaller than the automatic reduction line number setting is printed on fixed size paper. Default: 1 (Allow)

SW30 No.6 Inhibited to use SW30 No.7 Date/sender print position setup
Used to set whether date/sender information is printed inside the document area or outside the document area. Default: 0 (Outside of document)

SW25 No.1No.4 Automatic reduction rate setup


Used to set automatic reduction rate when automatic reduction print is valid. Default: 10%

SW30 No.8 Inhibited to use SW31 No.1, No.2 Report output (in transmission)
Used to set whether communication report is outputted or not after completion of sending (excluding sequential broadcast and sequential send request). Default: 1 0 (Only when transmission is failed.)

SW25 No.5, No.6 Transmission end sound tone


Used to set transmission end sound tone in transmission. Default: 0 1 (1000Hz)

SW25 No.7, No.8 Reception end sound tone


Used to set reception end sound tone in reception. Default: 0 1 (1000Hz)

SW31 No.3, No.4 Report output (In broadcast and sequential send request)
Used to set whether communication report is outputted or not after completion of sending (sequential broadcast and sequential send request). Default: 0 1 (All print)

SW26 No.1 Read completion sound


Used to set whether buzzer sound is made or not when scan is completed. In manual send or when scan is completed in direct send, buzzer sound is not made. Default: 0 (1sec)

SW31 No.5, No.6 Report output (in reception)


Used to set whether communication report is outputted or not in reception. Default: 0 0 (Print inhibited)

SW26 No.2 Inhibited to use SW26 No.3, No.4 Speaker volume setup
Used to set speaker volume. The following sounds are the targets of this setting. Alarm sound Send end sound Receive end sound Scan end sound Default: 0 1 (Small)

SW31 No.7, No.8 Contents of send document are printed in memory send
Used to set whether part of send document is printed on the communication report or not in memory send. Default: 1 0 (Only the address to which transmission is failed)

SW32 No.1No.4 Distinctive ringing (North America, Australia, New Zealand)


Used to set the ringing pattern as FAX reception. Default: 0 0 0 0 (OFF)

SW26 No.5No.8 Inhibited to use SW27 No.1No.6 Inhibited to use SW27 No.7, No.8 Recording paper tray selection
Used to select the recording paper tray used by FAX. Valid only when two cassettes are installed. Default: 0 0 (AUTO)

SW32 No.5 Inhibited to use SW32 No.6 Index print setup


Used to set whether the index is printed when outputting received document or not. Default: 0 (Not print)

SW32 No.7, No.8 Inhibited to use SW33 No.1 Page number print setup
Used to set whether the page number is added to the sender information print or not. Default: 1 (Yes)

SW28 No.1No.8 Inhibited to use SW29 No.1No.4 Number of auto switch calls of manual reception auto reception
Used to set the number of calls to switch to auto receive in manual receive mode. When set to 0, switch to auto receive is not made. Default: 0 time

SW33 No.2No.7 Inhibited to use

AR-FX13 FAX SOFT SWITCH 5 - 26

SW33 No.8 Reception data duplex print


Used to set whether duplex print of received data is made or not. Default: 0 (No)

SW38 No.8 Inhibited to use SW39 No.1No.3 Inhibited to use SW39 No.4No.8 DTMF signal send time
Used to set DTMF signal send time. Setting is made in binary input by the increment of 10ms. Default: 110ms (Other than Europe) / 80ms (Europe)

SW34 No.1, No.2 Flash send wait time (North America, U.K., Netherlands, Luxembourg, Belgium, France, Australia, New Zealand: Inhibited to use)
Used to set the time from off-hook to Flash send. Default: 1 0 (1sec)

SW40 No.1No.8 Number of times of recall in error


Used to set the number of times of recall when a communication error occurs. Setting is made in binary input. When set to 0, recall is not made. Default: 1 times

SW34 No.3, No.4 Inhibited to use SW34 No.5No.8 Signal send level Max.
Used to set the max. signal send level. Default: 8dBm

SW35 No.1 Cover function default setup


Used to set whether cover is added as default or not. When auto clear is made by pressing [Clear All] key, the machine returns to this setting. Default: 0 (No)

SW41 No.1No.8 Number of times of recall in busy


Used to set the number of times of recall when busy tone is detected during transmission. Setting is made in binary input. When set to 0, recall is not made. Default: 2 times

SW35 No.2 Inhibited to use SW35 No.3, No.4 CI delete max. OFF time
Used to set the max. wait time between detection of CI signal pulse (number of times) and detection of the next CI signal pulse. If CIK signal pulse is not detected within this time, the number of calls up to that time is cleared. Default: 0 0 (5sec) (Other than Europe) / 0 1 (10sec) (Europe)

SW42 No.1 Direct send recall (North America only)


Used to set whether direct send recall wait is allowed or not. Default: 0 (Allow)

SW42 No.2 FAX receive auto select by CNG detection


Used to set whether FAX receive auto select is enabled or not when CNG signal is detected with external telephone used. Default: 1 (Allow)

SW35 No.5No.8 Answering machine call number setting


Used to set the number of calls to switch to auto receive when answering telephone is not called in when the receive mode is set to the answering telephone connection mode. Setting is made in binary input. Default: 5 times (North America) / 6 times (Other than North America)

SW42 No.3 Auto receive select in answering telephone connection mode


Used to set whether auto receive select function in answering telephone connection mode is enabled or not. Default: 0 (Inhibit)

SW42 No.4No.7 Inhibited to use SW42 No.8 V.34 mode function in manual communication
Used to set whether V.34 mode is enabled or not in manual communication. When, however, SW43-1 is set to "0: OFF," V.34 mode is disabled even tough this switch is set to "1: ON." Default: 1 (ON)

SW36 No.1No.8 CNG detection completion time


Used to set the time for completion of CNG signal/mute detection in the answering telephone connection mode. Count is made from the last call signal. Setting is made in binary input. Default: 45sec

SW37 No.1No.8 Inhibited to use SW38 No.1, No.2 Protocol monitor


Used to set whether communication protocol result is printed or not after completion of communication. Default: 0 0 (Not printed.)

SW43 No.1 V.34 mode function


Used to set whether V.34 mode is enabled or not as a capacity of own machine in send/receive. Default: 1 (ON)

SW43 No.2, No.3 Inhibited to use SW43 No.4No.6 Symbol speed mask in V.34 receive
Used to set symbol speed mask in V.34 receive. Default: 1 0 1 (3429)

SW38 No.3 Protocol monitor save


Used to set whether the protocol monitor of the last communication is saved or not. When set to "Saved," the previous protocol monitor can be printed with SIM66-21. Default: 1 (Yes)

SW43 No.7, No.8 Inhibited to use SW44 No.1No.4 V.34 primary channel send speed
Used to set send start speed in V.34 send. Setting is made in binary input of N in "2400 (bps) x N" in the range of 2400bps 33600bps. N is set in the range of 0 15. When set to 0, 2400bps; when set to 15, 33600bps. When set to 2400bps, all of SW91 No. 1 8 must be set as "Disable". Default: 33600bps

SW38 No.4 Inhibited to use SW38 No.5, No.6 Flash send time (North America, U.K., Netherlands, Luxembourg, Belgium, France, Australia, New Zealand: Inhibited to use)
Used to set the Flash send time. Default: 0 0 (90ms)

SW38 No.7 Transfer function


Used to set whether transfer function is enabled or not. Default: 1 (Allow)

AR-FX13 FAX SOFT SWITCH 5 - 27

SW44 No.5No.8 V.34 primary channel receive speed


Used to set receive start speed in V.34 receive. Setting is made in binary input of N in "2400 (bps) x N" in the range of 2400bps 33600bps. N is set in the range of 0 15. When set to 0, 2400bps; when set to 15, 33600bps. When set to 2400bps, all of SW43 No. 4 6 must changed to 2400. Default: 33600bps

SW46 No.5 Summer time


Used to set whether summer time function is enabled or not. When set to 1, summer time function is enabled. When set to 0, summer time function is disabled. Default: 0 (Inhibit) (North America) / 1 (Allow) (Other than North America)

SW45 No.1 FAST mode


Used to set whether FAST function is enabled or not. Default: 0 (No)

SW46 No.6No.8 PBX setting (North America, U.K., Netherlands, Luxembourg, Belgium, Australia, New Zealand: Inhibited to use)
Used to set Connect/Not Connect to PBX and to set the external line connection method when connected to PBX. Default: 0 0 0 (Setting OFF)

SW45 No.2, No.3 Sequence of year/month/day in LCD, report, and sender record
Used to set the sequence of year/month/day in LCD, report, and sender record. Default: 0 1 (Month/Day/Year) (North America) / 1 0 (Day/Month/Year) (Other than North America)

SW47 No.1 Inhibited to use SW47 No.2 External telephone connection


Used to set whether external telephone is used or not. This switch must be set to YES in order to use external telephone. Default: 1 (Yes)

SW45 No.4 Time display format


Used to set time display format in LCD, report, and sender record. Default: 1 (am/pm) (North America) / 0 (24H) (Other than North America)

SW47 No.3No.8 Inhibited to use SW48 No.1, No.2 Tone/Pulse default setup
Used to set the dial type. Default: 1 0 (TONE)

SW45 No.5No.8 Scan effective image area main scan right edge image loss (RSPF)
Used to set image loss of scan effective area. Image loss on the right edge in RSPF main scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 24 dots. Default: 96 dots

SW48 No.3 Telephone line menu


Used to set whether tone/pulse setting is displayed on the menu or not. Default: 0 (Allow) (North America) / 1 (Inhibit) (Other than North America)

SW48 No.4 Inhibited to use SW48 No.5No.8 Scan effective image area main scan left edge image loss (RSPF)
Used to set image loss of scan effective area. Image loss on the left edge in RSPF main scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 24 dots. Default: 96 dots

SW46 No.1 Specification of print sequence in duplex print


Used to set the print sequence in duplex print of received data. When set to 1, an odd-number page is printed after printing the next even-number page. (214365...) When set to 0, print is made in the ordinary reception order. (123456...) Default: 1 (Print order (214365...))

SW49 No.1, No.2 Inhibited to use SW49 No.3No.8 Speaker sound volume pattern number in DTMF send
Used to set sound volume pattern in DTMF send. Default: 1

SW46 No.2 Specification of rotating direction duplex back surface print


Used to set whether the back surface is rotated 180 degrees in duplex print or not. When set to 1, the back surface is rotated 180 degrees and printed. When set to 0, the back surface is not rotated and printed. Default: 1 (180 degrees rotation)

SW50 No.1, No.2 Line monitor volume


Used to set on-hook monitor volume and line volume in FAX communication. Default: 1 0 (Medium)

SW46 No.3 Priority in the day of week


Used to set which is indicated first, day or day of week, when date format is in the sequence of day, month, and year. When set to 1, day of week is indicated first, and then day is indicated. When set to 0, day is indicated first, and then day of week is indicated. Default: 0 (No) (North America, U.K., Netherlands, Luxembourg, Belgium, Australia, New Zealand) / 1 (Yes) (Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway, France)

SW50 No.3No.8 Line monitor volume pattern number


Used to set line monitor volume pattern. Default: 16

SW51 No.1No.5 DTMF send level (High group) setup


Used to set high-group send level in DTMF signal send. Setting is made in binary input in the increment of 1.0dBm. Default: 6dBm (North America, Europe) / 5dBm (Australia, New Zealand)

SW46 No.4 Center No. in FAST mode


Used to set which is set as FAST center number, Service-No or Host-Tel-No. Default: 0 (Service-No.)

SW51 No.6 CED detection time


Used to set detection time of CED/ANSam signal for judgment of detection. Default: 1000ms

AR-FX13 FAX SOFT SWITCH 5 - 28

SW51 No.7, No.8 Busy tone detection cycle


Used to set detection cycle of pulses of busy tone for detection of busy tone. Default: 0 0 (2puls)

SW55 No.1No.7 CI signal OFF detection enable time


Used to set the min. OFF time for judgment of 1 pulse (1 call) of CI (call-in signal). If OFF time continues more than the set value, it is judged as 1 pulse. Setting is made in binary input in the increment of 10ms. Default: 1200ms (Other than New Zealand) / 1100ms (New Zealand)

SW52 No.1, No.2 Busy tone detection level


Used to set the mini. Detection level in busy tone detection. Default: 0 0 (43dB)

SW52 No.3 Inhibited to use SW52 No.4 Super G3 disabled in the last call-out of recall in case of an error
Used to set whether Super G3 is disabled or not in the last call-out of recall in case of a send error. When, however, the number of recall in case of a send error is 0, this function does not operate. Default: 0 (Super G3 disabled)

SW55 No.8 Inhibited to use SW56 No.1No.3 CI signal ON detection enable time
Used to set the min. ON time for judgment of 1 pulse (1 call) of CI (call-in signal). If ON time continues more than the set value, it is judged as 1 pulse. Setting is made in binary input in the increment of 10ms. Default: 155ms (North America, Europe) / 195ms (Australia, New Zealand)

SW52 No.5 Error process in RTN reception


Used to set whether RTN reception is judged as an error or not. (Only in G3 mode) When set to 1, RTN reception is not judged as an error. When set to 0, RTN reception is judged as an error. Default: 0 (Error)

SW56 No.4 Inhibited to use SW56 No.5, No.6 DT/BT detection frequency range
Used to set DT/BT detection frequency range. Default: 1 1 (245Hz650Hz) (Other than New Zealand) / 1 0 (360Hz440Hz) (New Zealand)

SW56 No.7, No.8 Inhibited to use SW57 No.1 Inhibited to use SW57 No.2 Sharp machine mode
Used to set whether communication is made in Sharp machine mode or not. Default: 1 (ON)

SW52 No.6, No.7 Inhibited to use SW52 No.8 V.34 control channel communication speed
Used to set control channel communication speed in V.34 mode. If the remote machine does not make 2400bps enable, the speed is always 1200bps. Default: 0 (1200bps)

SW53 No.1No.4 Maximum DTMF send level


Used to set the max. send level of DTMF signal. Setting is made in binary input in the increment of 1.0dBm. Default: 0dBm

SW57 No.3 Inhibited to use SW57 No.4No.8 Reception gain adjustment


Used to set reception gain correction. Setting is made in binary input in the increment of 0.5dBm. Default: 0.0dBm

SW53 No.5No.8 DTMF send level (difference between high and low level)
Used to set DTMF signal send level in low group by the difference from that in high group. Setting is made in binary input in the increment of 0.5dBm. Default: +2.0dBm (Other than New Zealand) / +1.5dBm (New Zealand)

SW58 No.1No.4 Dual wait inhibit time after CFR send


Used to set dual wait inhibit time after CFR send. Setting is made in binary input in the increment of 200ms. Default: 1600ms

SW58 No.5No.8 FSK signal settlement time in double wait


Used to set FSK signal settlement time in double (dual) wait. Setting is made in binary input in the increment of 50ms. Default: 550ms (7)

SW54 No.1No.4 Scan effective image area sub scan lead edge image loss (RSPF)
Used to set image loss in scan image area. Image loss on the lead edge in RSPF sub scan direction can be adjusted. When the set value is increased, image loss on the lead edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 96 lines

SW59 No.1, No.2 Inhibited to use SW59 No.3, No.4 Reception SED ON level
Used to set reception SED ON level. Default: 1 1 (48dB)

SW54 No.5No.8 Scan effective image area sub scan rear edge image loss (RSPF)
Used to set image loss in scan image area. Image loss on the rear edge in RSPF sub scan direction can be adjusted. When the set value is increased, image loss on the rear edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 144 lines

SW59 No.5, No.6 Transmission cable amplitude equalizer


Used to set transmission cable amplitude equalizer. Default: 0 0 (0dB) (North America, Europe) / 0 1 (4dB) (Australia, New Zealand)

SW59 No.7, No.8 Reception cable amplitude equalizer


Used to set reception cable amplitude equalizer. Default: 0 0 (0dB)

AR-FX13 FAX SOFT SWITCH 5 - 29

SW60 No.1No.4 Scan effective image area sub scan lead edge image loss (RSPF back surface)
Used to set image loss in scan image area. Image loss on the lead edge in RSPF bask surface sub scan direction can be adjusted. When the set value is increased, image loss on the lead edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 96 lines

SW71 No.1No.8 Inhibited to use SW72 No.1 EYE-Q check


Used to set TCF check in TCF reception. When set to 1, check is made only with EYE-Q value (EQM value). Therefore, TCF check is loosely made. When set to 0, check is made with received data and EYE-Q value (EQM value). Default: 0 (0 reception & EYE-Q check)

SW60 No.5No.8 Scan effective image area sub scan rear edge image loss (RSPF back surface)
Used to set image loss in scan image area. Image loss on the rear edge in RSPF bask surface sub scan direction can be adjusted. When the set value is increased, image loss on the rear edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 144 lines

SW72 No.2 ERR frame reception operation


Used to set operations when an image with an error frame is received. Default: 0 (Not continue process. (Error))

SW72 No.3, No.4 Waiting time for CED/ANSam send start


Used to set waiting time from when the line is connected and the machine enters FAX receive state to when CED/ANSam signal is send to the line. Default: 0 0 (2.25sec)

SW61 No.1No.8 Inhibited to use SW62 No.1No.3 Inhibited to use SW62 No.4, No.5 V.8 mode ANSam signal send time
Used to set ANSam/CED signal send time. Default: 0 1 (4sec)

SW72 No.5 RTC EOL send times


Used to set number of times of RTC EOL send. Default: 1 (6 times)

SW62 No.6No.8 Inhibited to use SW63 No.1No.8 Inhibited to use SW64 No.1No.8 Inhibited to use SW65 No.1No.8 Inhibited to use SW66 No.1No.8 Inhibited to use SW67 No.1No.4 Make time (10PPS) setup
Used to set make time in dialing in 10PPS. Setting is made in binary input in the increment of 1ms. Default: 40ms (North America) / 33ms (U.K., Netherlands, Luxembourg, Belgium, France) / 41ms (Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway) / 31ms (Australia) / 34ms (New Zealand)

SW72 No.6 Inhibited to use SW72 No.7, No.8 CNG send start
Used to set CNG send time. Default: 0 0 (0.5sec)

SW73 No.1No.8 Inhibited to use SW74 No.1No.4 Print effective image area sub scan lead edge void
Used to set print image area void. The void amount on the lead edge in the sub scan direction can be adjusted. When the set value is increased, the void amount on the lead edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 32 lines

SW67 No.5No.8 Inhibited to use SW68 No.1, No.2 Line open delay time in dial test
Used to set time interval between end of dialing and opening the line. Valid only in dial test of simulation. Default: 0 0 (2sec)

SW74 No.5No.8 Inhibited to use SW75 No.1 Manual calibration setting when sending
Setting to execute the manual calibration or not when sending. In case of an abnormal current waveform, the auto calibration fails and the DTFM signal is deformed. This setting provides the countermeasure against that problem. Default: 0 (OFF)

SW68 No.3, No.4 Inhibited to use SW68 No.5No.8 T1 timer setup


Used to set time for connection of the line when the remote machine does not respond in FAX communication. The time of ITU-T standard is 35 5sec. Setting is made in binary input in the increment of 5sec. Default: 40sec

SW75 No.2 Manual calibration setting when a signal arrives


Setting to execute the manual calibration or not when a signal arrives. In case of an abnormal current waveform, the auto calibration fails and the transmission is affected. This setting provides the countermeasure against that problem. Default: 0 (OFF)

SW69 No.1No.8 Inhibited to use SW70 No.1No.3 Inhibited to use SW70 No.4 Reception waiting time between frames
Used to set reception wait time between frames. Default: 0 (3.4sec)

SW75 No.3, No.4 Communication end sound (Buzzer sound length) setting
Used to set the length of communication end buzzer sound in communication. Default: 0 0 (3sec)

SW70 No.5, No.6 Preamble send time of 300bps


Used to set preamble send time of 300bps. Default: 0 1 (1.0sec)

SW70 No.7, No.8 RCP send times


Used to set number of times of RCP frame send. Default: 0 0 (3 times) AR-FX13 FAX SOFT SWITCH 5 - 30

SW75 No.5No.8 Print effective image area main scan void


Used to set void amount in print image area. The void amount in the main scan direction can be adjusted. When the set value is increased, the margins on the right and the left are increased. Setting is made in binary input in the increment of 16 dots. Default: 48 dots

SW82 No.1No.4 OC scan size default setting


Used to set OC scan default size. Default: 0 0 0 1 (LETTER) (North America) / 0 0 1 1 (A4) (Other than North America)

SW82 No.5No.8 Inhibited to use SW83 No.1, No.2 Inhibited to use SW83 No.3No.8 Speaker sound volume setting pattern number
Used to set sound volume pattern of communication end and scan end. Default: 1

SW76 No.1 Scan magnification ratio adjustment (main scan) flag


Used to set the main scan magnification ratio in scan. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)

SW84 No.1No.8 Inhibited to use SW85 No.1No.8 Inhibited to use SW86 No.1No.8 Inhibited to use SW87 No.1No.8 Inhibited to use SW88 No.1No.8 Inhibited to use SW89 No.1No.8 Inhibited to use SW90 No.1No.8 Inhibited to use SW91 No.1 Symbol speed 3429 send enable in V.34 send
Used to set whether symbol speed of 3429Hz is allowed or not in V.34 send. Default: 1 (Enable)

SW76 No.2No.8 Scan magnification ratio adjustment (RSPF main scan)


Used to set the main scan magnification ratio in RSPF scan. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%

SW77 No.1 Scan magnification ratio adjustment (sub scan) flag


Used to set the sub scan magnification ratio in scan. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)

SW77 No.2No.8 Scan magnification ratio adjustment (RSPF sub scan)


Used to set the sub scan magnification ratio in RSPF scan. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%

SW91 No.2 Symbol speed 3200 high carrier send enable in V.34 send
Used to set whether use of high carrier is allowed or not when symbol speed of 3200Hz is selected in V.34 send. When high/low carriers are "disable", 3200Hz cannot be selected. Default: 1 (Enable)

SW78 No.1 Print magnification ratio adjustment (main scan) flag


Used to set the main scan magnification ratio in print. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)

SW91 No.3 Symbol speed 3200 low carrier send enable in V.34 send
Used to set whether use of low carrier is allowed or not when symbol speed of 3200Hz is selected in V.34 send. When high/low carriers are "disable", 3200Hz cannot be selected. Default: 1 (Enable)

SW78 No.2No.8 Print magnification ratio adjustment (main scan)


Used to set the main scan magnification ratio in print. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%

SW91 No.4 Symbol speed 3000 high carrier send enable in V.34 send
Used to set whether use of high carrier is allowed or not when symbol speed of 3000Hz is selected in V.34 send. When high/low carriers are "disable", 3200Hz cannot be selected. Default: 1 (Enable)

SW79 No.1 Print magnification ratio adjustment (sub scan) flag


Used to set the sub scan magnification ratio in print. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)

SW91 No.5 Symbol speed 3000 low carrier send enable in V.34 send
Used to set whether use of low carrier is allowed or not when symbol speed of 3000Hz is selected in V.34 send. When high/low carriers are "disable", 3200Hz cannot be selected. Default: 1 (Enable)

SW79 No.2No.8 Print magnification ratio adjustment (sub scan)


Used to set the sub scan magnification ratio in print. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%

SW91 No.6 Symbol speed 3429 enable in V.34 communicate


Used to set whether use of 3429Hz is allowed or not as symbol speed in V.34 communicate. Default: 1 (Enable)

SW80 No.1No.8 Destination information


Used to set country code.

SW81 No.1No.8 Language information


Used to set language.

SW91 No.7 Symbol speed 2800 enable in V.34 communicate


Used to set whether use of 2800Hz is allowed or not as symbol speed in V.34 communicate. Default: 1 (Enable)

AR-FX13 FAX SOFT SWITCH 5 - 31

SW91 No.8 Symbol speed 2743 enable in V.34 communicate


Used to set whether use of 2743Hz is allowed or not as symbol speed in V.34 communicate. Default: 1 (Enable)

SW104 No.1No.4 Scan effective image area main scan left edge image loss (RSPF back surface)
Used to set image loss in scan image area. Image loss in RSPF back surface main scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 24 dots. Default: 96 dots

SW92 No.1No.8 Inhibited to use SW93 No.1No.8 Inhibited to use SW94 No.1No.8 Inhibited to use SW95 No.1No.8 Inhibited to use SW96 No.1No.8 Inhibited to use SW97 No.1No.8 Inhibited to use SW98 No.1No.8 Inhibited to use SW99 No.1No.8 Inhibited to use SW100 No.1No.8 Inhibited to use SW101 No.1No.4 Print effective image area sub scan lead edge void (Back surface)
Used to set void amount in print image area. Void amount on the lead edge in sub scan direction can be adjusted. When the set value is increased, the margin on the lead edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 32 lines

SW104 No.5No.8 Scan effective image area main scan right edge image loss (RSPF back surface)
Used to set image loss in scan image area. Image loss on the right edge in RSPF back surface main scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 24 dots. Default: 96 dots

SW105 No.1 Scan magnification ratio adjustment (OC main scan) flag
Used to set the main scan magnification ratio in OC scan. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)

SW105 No.2No.8 Scan magnification ratio adjustment (OC main scan)


Used to set the main scan magnification ratio in OC scan. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%

SW101 No.5No.8 Print effective image area sub scan rear edge void (Back surface)
Void amount on the rear edge in sub scan direction can be adjusted. When the set value is increased, the margin on the read edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 48 lines

SW106 No.1 Scan magnification ratio adjustment (OC sub scan) flag
Used to set the sub scan magnification ratio in OC scan. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)

SW102 No.1No.4 Scan effective image area main scan left edge image loss (OC)
Used to set image loss in scan image area. Image loss on the left edge in OC main scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 24 dots. Default: 96 dots

SW106 No.2No.8 Scan magnification ratio adjustment (OC sub scan)


Used to set the sub scan magnification ratio in OC scan. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%

SW102 No.5No.8 Scan effective image area main scan right edge image loss (OC)
Used to set image loss in scan image area. Image loss on the right edge in OC main scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 24 dots. Default: 96 dots

SW107 No.1 Scan magnification ratio adjustment (RSPF back surface main scan) flag
Used to set the main scan magnification ratio in RSPF back surface scan. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)

SW107 No.2No.8 Scan magnification ratio adjustment (RSPF back surface main scan)
Used to set the main scan magnification ratio in RSPF back surface scan. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%

SW103 No.1No.4 Scan effective image area sub scan lead edge image loss (OC)
Used to set image loss in scan image area. Image loss on the lead edge in OC sub scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 16 lines. Default: 96 lines

SW108 No.1 Scan magnification ratio adjustment (RSPF back surface sub scan) flag
Used to set the sub scan magnification ratio in RSPF back surface scan. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)

SW103 No.5No.8 Scan effective image area sub scan rear edge image loss (OC)
Used to set image loss in scan image area. Image loss on the rear edge in OC sub scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 16 lines. Default: 144 lines

AR-FX13 FAX SOFT SWITCH 5 - 32

SW108 No.2No.8 Scan magnification ratio adjustment (RSPF back surface sub scan)
Used to set the sub scan magnification ratio in RSPF back surface scan. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%

SW109 No.1 Print magnification ratio adjustment (Main scan back surface) flag
Used to set the main scan magnification ratio in back surface print. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)

SW109 No.2No.8 Print magnification ratio adjustment (Main scan back surface)
Used to set the main scan magnification ratio in back surface print. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%

SW110 No.1 Print magnification ratio adjustment (Sub scan back surface) flag
Used to set the sub scan magnification ratio in back surface print. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)

SW110 No.2No.8 Print magnification ratio adjustment (Sub scan back surface)
Used to set the sub scan magnification ratio in back surface print. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%

AR-FX13 FAX SOFT SWITCH 5 - 33

[6] TROUBLE CODES


1. Trouble codes
A. Trouble codes list
Main Sub Details of trouble code code F6 10 FAX board trouble U1 03 FAX board battery error Error code Communication (Communication report result result) column 34 Cancel Communication interruption content An interruption command is made during transmission or reception. A reservation is canceled. An interruption command is entered with the interruption key. Power OFF during transmission or reception

B. Details of trouble codes


Main Sub Details of trouble code code F6 10 Content FAX board trouble Detail Communication trouble between MCU and FAX control PWB Cause FAX control PWB connector disconnection Defective harness between FAX control PWB and MCU PWB Motherboard connector pin breakage FAX control PWB ROM error/Data error IC on FAX PWB causes abnormality Check Check connector/harness of FAX control and PWB and MCU PWB. remedy Check the grounding of the copier. Check FAX control PWB ROM. Replace the FAX PWB. U1 03 Content FAX board battery error Details The SRAM backup battery voltage on FAX PWB falls. Cause The SRAM backup battery voltage on FAX PWB falls. Check Check voltage of the SRAM back up battery. and Replace the battery. remedy

35 36 37 38 39

Power OFF (Recording paper empty) (Recording paper jam) Reception memory over (Discrepancy in the number of sheets) (Interface not accepted) Transmission length over

Memory over during reception

40 41

42

Reception length over Communication (OK) Document error (Image quality error) No response from the other party (Communication error) OK No send request function on the other party

43 44 45 46

2. Communication error codes


A. Error code identification
Communication error xx (xxxx) (In print out, the communication error display is made. In FAX status check, NGxxxxxx is displayed. When transmission or reception is not executed normally due to distur-bance in protocol signals and image signals by the trouble in the line, the code of 6 digits is displayed on the transmission result check menu (reception result check menu). Upper 2 digits of a communication error code: 00 58 (error code) is displayed. (Communication result code) Lower 4 digits of a communication error code: Error code1, Error code 2 1) Refer to the communication result code. 2) Refer to error code 1. 3) Refer to error code 2. (Error code 1 other than V.34 mode is 00.)

The length of transmission data of one page exceeds the range during transmission. The length of reception data of one page exceeds the range during reception. Communication enable before transmission A document jam during direct transmission

The FAX signal from the other party cannot detect within T1 time.

47 48 49

50

<Communication result code>


Error code Communication (Communication report result result) column 0 31 For details of 0 31, refer to the communication result code. 33 Busy Communication interruption content Depends on the communication disconnection position. For 16 or later, V.34 mode communication. The calling side cannot connect the line with the other party. 51

52

Communication normal end The other party has no send request function when receiving a send request. The other party has no data to send. Send request not DCN is received for DTC accepted when sending a send request. There is no data to send when sending a send request. Send request Discrepancy in the enable enable number number when sending a discrepancy send request. Discrepancy in the system number when sending a send request. No confidential The other party has no function on the confidential function when other party sending a confidential message. (Including the other companys machines)

AR-FX13 TROUBLE CODES 6 - 1

Error code Communication (Communication report result result) column 53 Confidential function not accepted 54 Confidential box No. NG

<Error codes 1>


Communication interruption content Error codes 1 are fixed to 00.

55

56

57

58

DCN is received for NSS when receiving a confidential message. A confidential box number which is not registered is directed when receiving a confidential message. No interface The other party has no function on the interface function when other party sending an interface command. Interface not DCN is received for NSS accepted when sending an interface command. A receiving station number which is not registered is directed when receiving an interface command. Interface ID Discrepancy in the interface discrepancy ID when receiving an interface command. Reception Transmission is made from a inhibition number reception inhibition number.

<Error codes 2>


Error codes 2 01 02 03 04 05 06 07 08 10 11 12 13 14 15 20 21 22 23 24 25 26 30 Transmission/ Reception Transmission length over Transmission EOL time over Reception Carrier detection time up Reception Polarity reversion detection (in phase C) Transmission/ Reception 8 min over (in phase C) Transmission Memory image decoding error Reception Memory image decoding error Transmission Time up between frames in phase C Transmission/ Reception Communication request NG Reception Polarity reversion detection Reception Invalid command reception Reception Time over (1min timer/6sec timer) Reception PUT error Reception Time out occurrence during shift from Reception Primary to Control in V.34 mode Polarity reversion detection Transmission Invalid command reception Transmission Fall back retry number over Transmission Resend over of retry number Transmission Time over (T5 timer) Transmission Time over (T5 timer) in V.34 mode Transmission Time out occurrence during shift from Transmission Primary to Control in V.34 mode Communication error due to Transmission/ communication abnormality between Reception FAX_SUB and FAX_MAIN Content of communication interruption

<Communication result codes>


Error code 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Final reception signal (Transmitting side) Abnormal signal NSF, DIS CFR FTT MCF PIP, PIN RTN, RTP No signal PPR Final reception signal (Receiving side) Abnormal signal NSS, DCS NSC, DTC EOP EOM MPS PRI-Q DCN PPS-EOP PPS-EOM PPS-MPS, PPS-NULL RR CTC EOR-Q PPS-PRI-Q Abnormal signal NSS, DCS NSC, DTC PPS-EOP PPS-EOM PPS-MPS, PPS-NULL PRI-Q DCN RR CTC EOR-Q PPS-PRI-Q V.8 Phase-1 V.8 Phase-2 V.8 Phase-3

RNR CTR ERR

Abnormal signal NSF, DIS CFR FTT MCF PIP, PIN RTN, RTP No signal PPR RNR CTR ERR V.8 Phase-1 V.8 Phase-2 V.8 Phase-3

(Note) For error codes 16 31, V.34 mode communication.

AR-FX13 TROUBLE CODES 6 - 2

FAX MAIN PWB (TEL/LIU) (North America)


R1005 5.36KF 1/4W (3226) R1006 5.36KF 1/4W (3226) R1007 5.36KF 1/4W (3226) RGDTR13 DAA3.3V 1.78kF 2W (N.M.)

1/6

4
4
Q2 2SD1733 DAA3.3V C15 B0.22uF/16V(1608) C14 B1uF/16V(2125) IC 1 TP25 TP16 TP13 R3 10(2125) 150pF/AC250V(7.5mm) Si3021-FS TP21 TP23 C10 B0.1uF/16V(1608) TP317 DAAGND C9 B1000pF 10(2125) TP12 R1009 2.2K(2125) TP26 TP1 Si3015-FS TP15 TP17 TP4 TP3 C5 R2 TP24 C1005 B0.1uF/50V(2125) C4 10pF/50V(1608) IC 3 MCLOCK ASPCLK ABITCLK ARXD ATXD AFERST_L R11 0R(1608) DAA3.3V R1008 150(1608)

Q1 2SC4548(E) C E

Q1000 2SA1759 E C

R 12 100kF(1608)

16 15 14 13 12 11 10 9 FILT2 FILT RX REXT REXT2 REF VREG2 VREG QE2 DCT IGND C1B RNG1 RNG2 QB QE

1 2 3 4 5 6 7 8

TP30 16 15 14 13 12 11 10 9

OFHK MCLK RGDT/FSD FSYNC M0 SCLK VA VD GND SDO C1A SDI M1 FC/RGDT AOUT RESET

1 2 3 4 5 6 7 8

TP8 R8 10K

R1001 78.7F(1608)

R1004 120K(1608) RL Z5.6

402F(1608)

DAAGND DAAGND C3 B0.22uF/10V(1608) SPOUT

B1800pF/50V(1608)

9 .31kF(1608)

[7] CIRCUIT DIAGRAM

Z D1001 R D43FM

5.36kF 1/4W(3226)

5.36kF 1/4W(3226)

5.36kF 1/4W(3226)

1.78kF 2W(N.M.)

B0.1uF/16V(1608)

RL Z5.6

TP18 R1000 C1001 ZD1

C1003

D2 D AN217

C1004 B0.01uF/50V(1608)

B0.1uF/16V(1608)

AK
D1 D AN217 A C13 B0.022uF/250V(2125) TPGND C12 (3216)N.M.

R1002

TP31 R 42 R1015

215F(1608)

AK

C1000

R1010

R1016

R4

C1002 B0.68uF/16V(2125)

Z D1000

0R(N.M.) +3.3V DAA3.3V

3
C11 150pF/AC250V(7.5mm) DAAGND

1. FAX MAIN PWB (North America)

Q1001 2SC4548(E)

3
DAAGND G ND

MJ1 TP27

L3

R1013 0R(1608 N.M.)

FB1 BLM31A601S

L1 TWKA-221KNP

R1011 56k(2125)

C1008 B560pF/250V(2125)

L1 L2
D6

SBT-0260

C6 2200pF(KH)

MJ-62J-RD315/MJ-66J-RD315 FL1 ST110AV VA1

SBT-0260

DSS-401M

R 14 10M(1608)

1 2 3 4 5 6 2 1

SA2

L4

+24V

SA3 DSS-401M

3
DSS401M(N,M.) S1ZB60 R1012 56k(2125) TP33 C1009 B560pF/250V(2125)

SA1

B0.01uF/250V(2125 N.M.) C 16

DSS-401M

C7 2200pF(KH)

FB2 BLM31A601S

L2 TWKA-221KNP

R 15 10M(1608)

R1017 0R (1608) D1000 1SS355

R Y1 A OUAZ-SH-124DZ 1

2
C34 R41 10k 1W D7 1SS355 Z D3 MTZJ30B C ID_L

Z D4 HZS2A1

PC2A TLP620

AR-FX13 CIRCUIT DIAGRAM 7 - 1


C1007 C1006 B3 9 00pF/16V(1608) B3 9 00pF/16V(1608)

2
3

R1014 0R(1608 N.M.)

2
R Y1 B

4
OUAZ-SH-124DZ

Q3 DTC123JKA B

TP279 R85 10K

H1 0.47uF/250V DAAGND

G ND PC1A PC817X PC1B PC817X C61 B1000pF

G ND

G ND

MJ2

L6

BT1 LT1 TEL1 TEL2 LT2 BT2


R43 9 1 1/4W

1 2 3 4 5 6

SBT-0260

MJ-62J-RD315/MJ-66J-RD315

Z D5 HZS2A1

R44 30 1/4W EXHKD_L PC2B TLP620

C63 B1000pF

L5

1
G ND

SBT-0260

FAX MAIN PWB (SPEAKER) (North America)


V re f +5V

2/6

5 6k 5 6k 5 6k 5 6k

D
R1 64 R1 7 0 R1 69 R1 66 V re f V re f 1M R173 10K(N.M.) R179 100k R180 200K R167 1K C145 100pF

C138 0.1 u F

SPOUT

TP310

C135 0.1 u F R168 3.3K R1 6 2 TP311 IC11 C134 0.1 u F IC10 C132 0.1 u F TP292 TP297 TP341 R158 3.3K TP293 TP296 R176 3.3k TP338 TP337

BZ

TP316 R172

20k

TP315

TP312

3 X 4 2 3 1 7 8

C N3

5
IC12 NJM2113M

TP331

R181

0R

1 2
B2B-PH-K-S

+5V

+5V

C136 4700pF

R171 1. 6 k

C139 2200pF

13 TP313 14 TP314 15 TP309 12 1 5 2 4 X0 X1 X2 X3 X4 X5 X6 X7 VDD


C137 0.1 u F C133 0.1 u F C143 A 4 .7u F/5 0V R177 22k AG SPMUTE TP322 +5V C142 A 4 .7u F/5 0V

16 VDD

R157 R159 R156 R161 R153 R160 R155

5 .1k 10k 18K 33K 62K 100K 200K

TP303 TP304 TP305 TP302 TP295 TP298 TP294 TP299

13 14 15 12 1 5 2 4 X0 X1 X2 X3 X4 X5 X6 X7 16
C144 A 4 .7u F/5 0V

6 11 10 9 INH A B C VEE VSS


BU 4 0 5 1BCF AG AG AG

7 8 VEE VSS

6 11 10 9 INH A B C 7 8

AG BU 4 0 5 1BCF

AG

+5V

R163 4 .7k +5V

R165 4 .7k

AG

VOLCNT_A

TP308

4 . 7k

R1 54

R1 5 2

4 . 7k R1 5 1

VOL_A

TP306

VOL_B

TP301

VOL_C

TP300

4 . 7k

VOLCNT_B

TP307

AR-FX13 CIRCUIT DIAGRAM 7 - 2


+5V V re f R174 1k Z D6 HZS2C1 C141 A 4 .7u F/5 0V AG AG G ND AG

FAX MAIN PWB (SRAM & FLASHROM (16M)) (North America)

3/6

D[ 7 :0]

A [21:0] A0 TP197

D
IC 9 IC 8

I/O7 I/O6 I/O5 I/O4 I/O3 I/O2 I/O1 I/O0

29 28 27 26 25 23 22 21

D7 D6 D5 D4 D3 D2 D1 D0

NC
BAT

A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0

10 7 11 4 12 1 31 2 3 13 14 15 16 17 18 19 20 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 9


A17 TP239 TP240 TP241 TP242 TP243 TP244 TP245 TP275 TP274 TP247 TP246 TP217 TP196 TP216 TP215 D7 D6 D5 D4 D3 D2 D1 D0 F _ R YB Y TP144 +3.3V C94 0.1 u F

DQ15 DQ14 DQ13 DQ12 DQ11 DQ10 DQ9 DQ8 DQ7 DQ6 DQ5 DQ4 DQ3 DQ2 DQ1 DQ0 RY/BY BYTE VPP VCC 13 37 15 47

45 43 41 39 36 34 32 30 44 42 40 38 35 33 31 29

VCC
C73 0.1 u F TP276 + C74 A 47u F/25V F_WP CS_FL RESETL

CS_S0L CS_S1L TP83

A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1

TP175 TP145 TP146 TP129 TP130 TP151 TP153 TP155 TP156 TP176 TP152 TP154 TP157 TP177 TP178 TP179 TP180 TP193 TP194 TP195

9 16 17 48 1 2 3 4 5 6 7 8 18 19 20 21 22 23 24 25 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0

30 6 32 5 CE1 CE2 OE WE VSS 24


CS1 6 LV102 43EIR55 G ND A21 S2 9 AL01 6D70TFI020 G ND C72 100pF TP147 R94 75

26 12 28 11 14 TP174 10 CE RP OE WE WP NC GND GND 27 46

C
OEL WEL TP148 TP149

G ND

+3.3V

BAT

+3.3V TP89 RTC_DATA RTC_CLK C N4 TP71 L_BTRTC_CE0H TP73 TP72

R73 10k

IC 5 C55 C54

7 6 5
TP85

DATA CLK CE 1 I/OSM8578BV

VDD XTXT VSS

8
12pF 12pF

R37 560 R5 100k

G ND

TP66 G ND

TR3 KTA1504

CS_S1L

R60 1k

G ND

AR-FX13 CIRCUIT DIAGRAM 7 - 3


1 2
B2B-PH-K-S IC 2

+3.3V

BAT

3 2 4
C59 0.1 u F R79 10k C52 12pF(N.M.) C51 1 8 pF(N.M.)

Z D2 UDZ2.0B

TR4 KTA1504

4 3

1 2

X3 DT-3 8 32.768KHz

TP67

TP70

R35 20k

R38 360 G ND TP32

B
VCC
PST3426

R36 1k

C31 0.1 u F

D3 1SS355

1 OUT NC 3 TP34 GND 2

B
G ND G ND JP1 0R

TP68 G ND

TP69

R6 1k

TR2 KTC3875

R61 1k

G ND

BT1 HL 5 0-A G ND G ND

TP28 C_BT

TR1 DTC363EKA C B

G ND

+3.3V

FAX MAIN PWB (MN195006Q) (North America)


+3.3V

4/6

D
+3.3V +3.3V

C30 F L7 F L9 F L6 F L5 F L2 FL13 FL1 4 F L8 F L4 F L3 A 47u F/25V

C93 A 47u F/25V

MDM3.3V TP76 C20 A33 u F/10V +1.8V TP63

G ND

G ND

+3.3V

R53

4 .7k

+3.3V

MDM_IRQ C LKIN R47 33 +3.3V G ND +3.3V R50 33 X1 S G -7 10ECK 2 4.576M S-L3 TP55 3 OUT OE 1 FB11 ACH32 N.M.

TP65

R54

0R

TP81

C47 0.1 u F C49 0.1 u F C26 0.1 u F C40 0.1 u F C43 0.1 u F C45 0.1 u F C19 A33 u F/10V C22 0.1 u F C21 0.1 u F

C24 0.1 u F C25 1uF C46 0.1 u F C44 0.1 u F C42 1uF C23 1uF C27 0.1 u F C29 0.1 u F C48 0.1 u F C41 1uF

55 54

92 78 68 44 30 15 3

34

97 86 62 42 21 9

53 52

G ND

2 GND
C65 C 47 0 u F C66 0.1 u F

IC 4

VDD

FL12 ZJSR 5 101(22000p)

VDD3 VDD3 VDD3 VDD3 VDD3 VDD3 VDD3

VDD2 VDD2 VDD2 VDD2 VDD2 VDD2

1 T3IRQ
TP61 R48 47K TP60 TP56 TP48 TP47 R18 MCLOCK C LKIN C N1 C39 10pF R46 33(N.M.) 75 TP36

AVDD

VDDREG VDDREG

CS_ML OEL WEL

+3.3V

R28 R29

47K 47K

TP49 TP50

75 74 73 71 72 NDPCS NDPRD NDPWR NUB NLB NRESET CXIN CXOUT CLKOUT CNT LON 39 38 43 37 51 41

REGOUT REGOUT

NDBGREQ DBGMOD PLLON TMS TCK TDI TDO

26 27 36 33 31 29 28

G ND

G ND

M_RESETL

C36 100pF

G ND

+3.3V

SCANNT MINTEST INTEST MODE0 MODE1


G ND G ND +3.3V MN195006E

A[21:0] G ND

A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0

100 98 96 95 94 93 91 90 88 87 85 84 45 46 48 49 50 57 58 1 2 3 4 5 6
A2-6 PA-2.54DSA(NM)

DPA11 DPA10 DPA09 DPA08 DPA07 DPA06 DPA05 DPA04 DPA03 DPA02 DPA01 DPA00 EYECLK EYEDAT

R19 47K

R20 47K

R22 47K R10 R21 100 100 R9 100

BR1

AVSS

35

G ND R34 R59 47K 0R TP10 AFERST_L

99 89 80 70 64 56 47 40 32 23 17 11 5

VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS

AR-FX13 CIRCUIT DIAGRAM 7 - 4


ABITCLK ASPCLK ATXD ARXD
R24 0R +3.3V

D[ 7 :0]

59 60 63 61

TP29 TP37 TP42 TP7

TP19 TP20 TP11 TP9

B
G ND TP45 TP53 TP58 TP59 TP52 TP51 +3.3V R55 R58 47K 47K

5 6 7 8 BBITCLK BSPCLK BTXD BRXD GPIO0 GPIO1 GPIO2 GPIO3 GPIO4 GPIO5 76 77 79 81 82 83
R32 R33 R56 47K 47K 47K

ABITCLK ASPCLK ATXD ARXD

+3.3V

R23 47K

B
G ND

D7 4 5 D6 3 6 D5 2 7 D4 1 8 BR 7 D3 4 D2 MNR0 4 33 3 D1 2 D0 1 R91 47K MNR0 4 R92 47K R93 47K R95 47K R96 47K R97 47K R98 47K R52 47K

33

TP78 TP77 TP79 TP62 TP92 TP93 TP94 TP95 TP96 TP98 TP97 TP99 TP100 TP101 TP102 TP80

25 24 22 20 19 18 16 14 13 12 10 8 7 6 4 2 DPD15 DPD14 DPD13 DPD12 DPD11 DPD10 DPD09 DPD08 DPD07 DPD06 DPD05 DPD04 DPD03 DPD02 DPD01 DPD00 65 66 69 67
TP39 TP43 TP44 TP38 R25 R26 R31 R27 47k 47k 47k 47k

G ND

8
D [7:0] A[21:0] MCU_D[7:0] PB_A[7:0] PB_D[7:0]

FAX MAIN PWB (ASIC_NEW_CILF) (North America)

5/6

D
PB_D0 PB_D1 PB_D2 PB_D3 PB_D4 PB_D5 PB_D6 PB_D7 FL17 IC 7 C80 0.1uF TP123 TP122 MCU_INT MCU_CEL MCU_OEL G ND FL11 C79 0.1uF G ND (N.M.) +3.3V (N.M.) +3.3V

BR17 MNR04 47 1 8 2 7 3 6 4 5

1 BR16 2 MNR04 47 3 4

8 7 6 5

+3.3V

BR24

TP126 TP124 TP125 TP121 TP140 TP138

BR21 M CU_D0 M CU_D1 M CU_D2 M CU_D3

1 2 3 4

8 7 6 5

MNR04 22K +3.3V R102 +3.3V FL18 (N.M.) PB_CS1L PB_AE0L 10K TP187 TP118 TP136 TP115 TP116

1 2 3 4

8 7 6 5

BR22

TP119 TP120 TP137 TP117

0R 8 7 6 5

MNR04 22K

PB_A7 PB_A6 PB_A5 PB_A4 PB_A3 PB_A2 PB_A1 PB_A0

BR23

1 2 3 4 1 2 3 4
MNR04 0R

8 7 6 5

BR5 MNR04 1 2 3 4 BR3 8 7 6 5 M CU_D4 M CU_D5 M CU_D6 M CU_D7

FL10 C78 0.1uF WEL +3.3V G ND

(N.M.)

+3.3V

1 2 3 4
C81 0.1uF PB_WEL PB_OEL RESETL W AKE_UP TP206 TP204 TP205 TP230 TP22 HS2L CID_L HS1L F _ R YB Y R137 +3.3V C102 0.1uF R131 G ND R130 10K 10K FL19 (N.M.) R139 10K 10K G ND EXHKD_L

8 7 6 5

MNR04(N.M.)

C
1 2 3 4
D8 DA204U JP2 T2B-SQ TP260 TP229 TP228 TP259 uPD65 9 44GM-P07-JED-A RGDT-

MNR04(N.M.)

C
+3.3V R68 RTC_CE0H RTC_CLK RTC_DATA CS_S0L

BR6

R103 R142 R104 R105

22K 22K 22K 22K

4 3 2 1

5 6 7 8

8 7 BR2 9 6 MNR04 10K 5

TP114 TP90 TP91 TP112 TP113

R78 R75 R76 R74

10K 10K 10K 10K

MNR04 10K R135 R141 R140 10K 10K 10K

TP111

BR26 MNR04 10K 1 8 2 7 3 6 4 5

CS_FL TP110 TP86 TP109 TP108 TP107 TP84

10K(N.M.) CS_OP1L CS_OP2L R71 R66 R65 R63 0R A21 C58 18pF FL16 C77 0.1uF (N.M.) +3.3V C56 18pF C53 18pF 100 100 100 CS_ML OEL WEL

R62 R100

10K 10K

BR 9

4 3 2 1

5 6 7 8 BR8 MNR04 10K

G ND

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 VDD PB_DAT_05 PB_DAT_04 PB_DAT_03 PB_DAT_02 PB_DAT_01 PB_DAT_00 TESTMODE0 PB_ADDR_07 PB_ADDR_06 PB_ADDR_05 PB_ADDR_04 PB_ADDR_03 PB_ADDR_02 PB_ADDR_01 PB_ADDR_00 PB_CE2_N PB_CE1_N PB_AE0_N VDD GND PB_WR_N PB_OE_N RESET_N WAKE_UP FGPI_07 FGPI_06 FGPI_05 FGPI_04 FGPI_03 FGPI_02 FGPI_01 FGPI_00 FGPIO_07 FGPIO_06 FGPIO_05 FGPIO_04 TCK TRST VDD GND GND PB_DAT_06 PB_DAT_07 CPU_INT_N CPU_CS_N CPU_RD_N VDD GND CPU_DT_00 CPU_DT_01 CPU_DT_02 CPU_DT_03 GND CPU_DT_04 CPU_DT_05 CPU_DT_06 CPU_DT_07 VDD GND FAXWRIN_N UART_RTS UART_CTS UART_SOUT UART_SIN RTC_ION RTC_CE RTC_SCLK RTC_SDATA FAXCS_N_00 FAXCS_N_01 FAXCS_N_02 FAXCS_N_03 FAXCS_N_04 FAXCS_N_05 FAXOE_N FAXWR_N FAXADD_21 GND GND

160 159 158 157 156 155 154 153 152 151 150 149 148 147 146 145 144 143 142 141 140 139 138 137 136 135 134 133 132 131 130 129 128 127 126 125 124 123 122 121

4 3 2 1 1 2 3 4 8 7 BR30 6 MNR04 10K 5

5 6 7 8

BR10

MNR04 10K

G ND

BR11

4 3 2 1

5 6 7 8

BR12 MNR04 100 1 8 2 7 3 6 4 5 TP103 TP105 TP104 TP106 TP131 TP134 TP132

MNR04 10K C_BT L_BTR129 G ND M_RESETL S +3.3V FL22 (N.M.) R127 10K BZ

4 3 2 1

5 6 7 8

BR25

G ND TP135 TP133 TP161 TP160 TP158 TP159 BR14

MNR04 10K

4 3 2 1
TP319 TP320 TP255 100 TP254

5 6 7 8

PB_D7 PB_D6 PB_D5 PB_D4 PB_D3 PB_D2 PB_D1 PB_D0 PB_A7 PB_A6 PB_A5 PB_A4 PB_A3 PB_A2 PB_A1 PB_A0 PB_CS1L PB_AE0L PB_WEL PB_OEL D7 D6 D5 D4 D3 D2 D1 D0 A21 A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 TP257 TP258 TP285 TP284 TP283 TP323 TP256 TP321 TP282

AR-FX13 CIRCUIT DIAGRAM 7 - 5


TP162 TP181 TP184 TP182 TP280 TP278 TP277 TP253 C101 0.1uF G ND F_WP SPMUTE TP318 +3.3V C100 0.1uF G ND FL21 (N.M.) VOL_C VOL_B VOL_A VOLCNT_B VOLCNT_A D7 R126 D6 R125 100 100 TP252 TP251 TP250 TP226 185TP TP183 TP202 TP198 TP200 TP199 TP201 TP220. TP218 TP219 TP221 TP223 TP222 TP248 TP225 TP224

MNR04 10K

1 2 3 4

8 7 6 5
MNR04 100

FL15 C76 0.1uF BR27

(N.M.)

+3.3V +3.3V

BR2

R101 A20 100 A19 A18 A17 BR13 A16 MNR04 100 1 8 A15 2 7 A14 3 6 A13 4 5 A12 A11 A10 A9 BR15 A8 1 8 A7 2 7 A6 3 6 A5 4 5 A4

BR4

1 2 3 4

8 7 6 5

B
1 2 3 4 8 7 6 5
MNR04 100 G ND C104 A47uF/25V

1 2 3 4

8 7 6 5

MNR04(N.M.)

MNR04(N.M.)

R82 R81 R80

22K 22K 22K

M CU_D7 M CU_D6 M CU_D5 M CU_D4 M CU_D3 M CU_D2 M CU_D1 M CU_D0 M CU_INT MCU_CEL MCU_OEL

R77 R67

10K 10K

WEL OEL

MNR04 100 A3 A2 A1 BR28 A0 1 8 2 7 3 6 4 5 R115 R116 R120 100 100 MNR04 100 0R(N.M.)

D0 D1 D2 D3 D4 D5 R121

+3.3V +3.3V 10K R117 10K +3.3V

G ND

R70 R69 R72 R136

10K 10K 10K 10K

TP87 TP82 TP88 TP227

C S_FL CS_ML CS_S0L F _ R YB Y

R122 10k(N.M.)

R133 R132

10K 10K

TP203 HS2L TP186 HS1L

41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 GND GND TMS NC TDI TDO FGPIO_03 FGPIO_02 FGPIO_01 FGPIO_00 TELELIN BEEP_O_V1 BEEP_O_V2 FGPO_15 FGPO_14 FGPO_13 FGPO_12 GND FGPO_11 FGPO_10 FGPO_09 FGPO_08 GND VDD FGPO_07 FGPO_06 FGPO_05 FGPO_04 FGPO_03 FGPO_02 FGPO_01 FGPO_00 FAX_DATA_07 FAX_DATA_06 VDD GND XIN XOUT GND GND

VDD FAXADD_20 FAXADD_19 FAXADD_18 FAXADD_17 FAXADD_16 FAXADD_15 FAXADD_14 GND FAXADD_13 FAXADD_12 FAXADD_11 FAXADD_10 FAXADD_09 FAXADD_08 FAXADD_07 FAXADD_06 FAXADD_05 FAXADD_04 GND VDD FAXADD_03 FAXADD_02 FAXADD_01 FAXADD_00 FAX_DATA_00 FAX_DATA_01 FAX_DATA_02 FAX_DATA_03 FAX_DATA_04 FAX_DATA_05 TMD0_OUT TOUT TESTB TMD2 TMD1 TMD0 SYSCLK_IN CLKSEL VDD

120 119 118 117 116 115 114 113 112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81

R134 R138

10k 10k

C96 100pF G ND R11 9 10k

C ID_L EXHKD_L

R118 10k

R128 R143

10K 22K

TP281 M_RESETL TP208 RESETL +3.3V

G ND + IC 6 C LKIN R89 TP143 C70 0.1uF G ND G ND C69 270pF G ND 510 TP173 TP57 TP142 TP172 R88 0R TP249 R123 0R G ND C68 0.1uF P2782A-08SR C99 100pF TP273 R124 75 G ND C98 0.1uF

FL20 C97 A47uF/25V

(N.M.)

+3.3V G ND G ND

1 2 3 4 Xin Xout S1 LF

G ND

VDD S0 FSOUT VSS

8 7 6 5

FAX MAIN PWB (MCU I/F) (North America)


R184 R185 +3.3V TP3.3V LC3S-Y(N.M.) ZJSR 5 101(22000p) FL25 ZJSR 5 101(22000p) FL24 ZJSR 5 101(22000p) FL23 TP5V LC3S-Y(N.M.) TP24V LC3S-Y(N.M.) IN3.3V +5V IN 5 V +24V IN2 4 V 0R 100 1 2 3 4

6/6
8 7 6 5
#MDM_IRQ #RESET#PB_nOE #PB_nWE #PB_nAE0 #PB_nCS1

R183

D
33pF 33pF 33pF FB10 MNR0 4 33 + C162 0.1 u F G ND G ND G ND G ND G ND G ND FB14 ACH32 N.M. + FB13 ACH32 N.M. C87 + A 47u F/35V

MDM_IRQ RESETL PB_OEL PB_WEL PB_AE0L PB_CS1L

TP189 TP190 TP207 TP188

33 5 6 7 8

4 3 2 1

TP339 TP336 TP333 TP335 TP334

BR20 MNR0 4 0R

B1000pF

100pF

A 47u F/25V C 85

C1 56

C1 47

C1 55

C1 54

C1 5 3

G ND

C1 58

PB_A[7 :0] 33 8 7 6 5 #PB_A0 #PB_A1 #PB_A2 #PB_A3 #PB_A4 #PB_A5 #PB_A6 #PB_A7

PB_A0 PB_A1 PB_A2 PB_A3 PB_A4 PB_A5 PB_A6 PB_A7

TP168 TP165 TP164 TP167 TP166 TP163 TP139 TP141

BR1 9 MNR0 4 0R 5 4 6 3 7 2 8 1 C N2

A 47u F/25V C1 6 0

D9 1SS3 55 (N.M.)

10pF/ 50V

FB12 ACH32 N.M.

C83 1000pF(N.M.)

C84 0.1 u F

5 6 7 8
33pF 33pF 33pF 33pF 33pF FB8 MNR0 4 33

4 3 2 1

TP328 TP325 TP327 TP324 TP326 TP288 TP290 TP287

FB9 MNR0 4 1 2 3 4

40

1 2 3 4

8 7 6 5

33pF

33pF

C1 5 2

C1 5 1

C1 5 0

33pF C1 57

BR1 8 MNR0 4 0R

C1 49

C1 48 C113

C11 7

C
B 4 0B-PNDZS-1

IN 5 V #MDM_IRQ #PB_nOE #PB_nAE0 #PB_A0 #PB_A2 #PB_A4 #PB_A6 #PB_D0 #PB_D2 #PB_D4 #PB_D6 #MCU_INT #MCU_nOE #MCU_D1 #MCU_D3 #MCU_D 5 #MCU_D 7

39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1
IN3.3V IN 2 4 V #RESET#PB_nWE #PB_nCS1 #PB_A1 #PB_A3 #PB_A5 #PB_A7 #PB_D1 #PB_D3 #PB_D5 #PB_D7 #MCU_ n CS #MCU_D0 #MCU_D2 #MCU_D 4 #MCU_D 6

40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2

G ND

G ND

PB_D[7 :0] TP289 TP264 TP266 TP263 TP265 TP262 TP233 TP232 33 8 7 6 5 #PB_D0 #PB_D1 #PB_D2 #PB_D3 #PB_D4 #PB_D5 #PB_D6 #PB_D7 +3.3V C28 0.1 u F TP35 R30 22 +3.3V C91 0.1 u F TP271 R112 22

PB_D0 PB_D1 PB_D2 PB_D3 PB_D4 PB_D5 PB_D6 PB_D7

FB4 MNR0 4 1 2 3 4

1 2 3 4
FB3 MNR0 4 33

8 7 6 5

33pF

33pF

33pF

33pF

33pF

33pF

33pF

33pF

+3.3V C114 0.1 u F TP191 R106 22

+3.3V C50 0.1 u F TP64 R57 22

+3.3V C106 0.1 u F TP231 R145 22

+3.3V C32 0.1 u F TP40 R39 22

+3.3V C57 0.1 u F TP54 R64 22

+3.3V C67 0.1 u F TP171 R87 22

C112

C111

C110

C11 6

C10 9

C10 8

C10 7

G ND

C11 5

G ND

G ND

G ND

G ND +3.3V +3.3V C159 0.1 u F TP342 +3.3V C2 0.1 u F TP6 R186 22 R7 22 +3.3V C146 0.1 u F TP332 R182 22 C88 0.1 u F TP170 R109 22

G ND

G ND

G ND

G ND

+3.3V C18 0.1 u F TP41 R17 22 G ND G ND G ND G ND G ND

+3.3V C1 0.1 u F TP5 R1 22

+3.3V C60 0.1 u F TP74 R83 22

+3.3V C 71 0.1 u F TP128 R 90 22

10pF/ 50V

10pF/ 50V

10pF/ 50V

C12 6

C12 5

C12 4

10pF/ 5 0V(N.M.)

10pF/ 5 0V(N.M.)

10pF/ 5 0V(N.M.)

10pF/ 5 0V(N.M.)

10pF/ 5 0V(N.M.)

10pF/ 5 0V(N.M.)

C11 9

C123

C12 8

C122

C11 8

C121

C12 7

10pF/ 5 0V(N.M.)

G ND

C120

10pF/ 5 0V(N.M.)

AR-FX13 CIRCUIT DIAGRAM 7 - 6


TP268 #MCU_INT #MCU_ n CS #MCU_nOE FB7 MNR0 4 8 7 6 5 47 1 TP267 2 3 4 +3.3V C129 0.1 u F TP270 R148 22 +3.3V C92 0.1 u F TP192 R113 22 +3.3V C161 0.1 u F TP340 R187 22 +3.3V G ND G ND G ND G ND +3.3V +3.3V +3.3V +3.3V C86 0.1 u F TP169 R108 22 C140 0.1 u F TP330 R175 22 C103 0.1 u F TP286 R178 22 FB6 MNR0 4 4 3 2 1 100 5 6 7 8 4 3 2 1

MCU_INT MCU_CEL MCU_OEL

TP269 TP291 TP238

R147 R146

0R 0R

TP236 TP234

G ND

G ND

G ND

+3.3V C131 0.1 u F TP329 R150 22 C75 0.1 u F TP150 R99 22

+3.3V C95 0.1 u F TP272 R114 22

+3.3V C33 0.1 u F TP46 R40 22

+3.3V C105 0.1 u F TP261 R144 22

G ND G ND G ND G ND G ND

+3.3V

MCU_D[7 :0]

C62 0.1 u F TP75 R84 22

C82 0.1 u F TP127 R107 22

A
FB5 MNR0 4 100

M CU_D0 M CU_D1 M CU_D2 M CU_D3 M CU_D 4 M CU_D 5 M CU_D 6 M CU_D 7

TP235 TP237 TP214 TP211 TP210 TP213 TP212 TP209

5 6 7 8

#MCU_D0 #MCU_D1 #MCU_D2 #MCU_D3 #MCU_D 4 #MCU_D 5 #MCU_D 6 #MCU_D 7

G ND

G ND

G ND

G ND

G ND

FAX MAIN PWB (TEL/LIU) (Europe, Australia, New Zealand)

1/6

R49

1.78kF 2W TP29 +3.3V RGDT-

4
Q4 2SD1266A(N.M.) 4 3 Q5 2SD1733

4
+3.3V

Q2 2SC4548(E) C E

+3.3V C20 B0.22u/16V(1608) C1A 150p(KH) C1 TP4 R1 10 1/10W(2125) N.M.(5750) TP25 10 1/10W(2125) TP3 TP24 R11 C11 10pF/50V(1608) C21 B1uF/16V(2125) TP15 IC 1 TP13 TP11 R17 2.2K 1/10W(2125) C4 B0.1u/50V(2125)

R14 0R(1608)

R 16 100kF(1608)

R1005 150(1608)

TP36

Q3 2SA1759 E C

MCLOCK ASPCLK ABITCLK ARXD ATXD AFERST_L

TP33 TP9 TP14 TP7 Si3015-FS

TP12

TP10

TP30 IC 2 16 MCLK 15 OFHK 14 RGDT/FSD FSYNC SCLK 13 M0 VD 12 VA SDO 11 GND SDI 10 C1A M1 FC/RGDT 9 AOUT RESET Si3021-FS

16 15 14 13 12 11 10 9 FILT2 FILT RX REXT REXT2 REF VREG2 VREG K QE2 DCT IGND C1B RNG1 RNG2 QB QE

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

TP23 R10 10K C13 B0.1u/16V(1608) C12 1000pF

78.7F(1608)

R15 120K(1608)

RL Z5.6

DAAGND DAAGND C14 B0.22u/ 16V(1608) DAAGND TP21 TPGND 0R 1/4W (N.M.) SPOUT

402F(1608)

AK
TP6 D1 D AN217 A ZD2

1.7 8kF 2W

ZD3 R D43FM

B1800p/50V(1608)

9 .31kF(1608)

C 22

R1002

B0.1u/16V(1608)

D2 D AN217

C17 B0.01u/50V(1608) TP16 C3 RL Z5.6 R3

B0.1u/16V(1608)

AK
N.M.(KH)

TP5

C163

215F(1608)

R2

TP31 R 46 C2

R1001

C1002 B0.68u/16V(2125)

ZD1

3
C16 N.M.(5750) 680 1/10W(1608) R4 TP19 150p(KH) A4.7uF/50V(NP) C5 33pF FB1 BLM31A601S L1 TP17 TP8 TWKA151KNP R1004 56k 1/10W(2125) C1005 B560p/250V(2125) C1006 N.M. (3216) C16A

Q1001 2SC4548(E)

TP32

C 19 B0.022u/250V(2125)

DAAGND C18 N.M.(3216)

G ND

C8

L4

MJ1

SBT-0260

R7 10R 1/4W

SA2

R6 10M(1608)

L1 L2
D3

L5

L2 TWKA102KNP

C6 N.M.(5750)

1 2 3 4 5 6
C6A 1000pF(KH)

SBT-0260 VA1

MJ-64J-RD315

DSS-401M

SA3 DSS-301L

FL1 ST110AV

3
DSS-301L(N.M.) S1ZB60 R1003 56k 1/10W(2125) C1004 B560p/250V(2125) TP34 C1003 N.M. (3216)

SA1

DSS-401M

C7 N.M.(5750)

C7A 1000pF(KH)

C 23 33pF

R20 10R 1/4W TWKA151KNP

C1008 C1007 B3 900p/16V(1608) B3 900p/16V(1608)

FB2 BLM31A601S L3

R 19 10M(1608)

C24

A4.7uF/50V(NP)

B0.01u/250V(N.M. 2125) C1001

+24V

2. FAX MAIN PWB (Europe, Australia, New Zealand)

R91 0R(1608)

TP18 R18 680 1/10W(1608) IC 3 +5V D6 TP174 TP175 C42 F0.1uF/16V HS1_L HS2_L R Y1 B 1SS355

G ND G ND

0.22uF/250V D5 1SS355 TLP621 PC1B TLP621

3 9 K 1W PC1A

MJ2

AR-FX13 CIRCUIT DIAGRAM 7 - 7


1 IN1 2 IN2
THS-56F

2
VCC OUT1 OUT2 AOUT GND 7 6 5 4 3

H1

+
RSB-24

16

Q9 DTC123JKA B

TP247 R92 10K

R54 0R 1/10W (2125)

R53 0R 1/10W (2125)

13
R Y1 A RSB-24

4
G ND G ND

11

C44 R52

Z D5 MTZJ30B C ID_L

C68 0.1uF

G ND

L7

BT1 LT1 TEL1 TEL2 LT2 BT2

1 2 3 4 5 6

SBT-0260

MJ-62J-RD315

L6

SBT-0260

FAX MAIN PWB (SPEAKER) (Europe, Australia, New Zealand)


V ref +5V

2/6

C138 0.1uF R171 1K TP319 V ref R183 1M R182 100k 200K

R168 R174 R173 R170

5 6k 5 6k 5 6k 5 6k

D
C145 100pF

SPOUT

TP317

C135 0.1uF TP321 IC12 C134 0.1uF IC11 C132 F0.1u/16V R166 TP336

BZ

TP324 R176

20k

TP323

R172 TP320 3.3K

3 X 3 4 2 3 1 7 8
TP333 C144 A4.7u/50V C133 F0.1u/16V C143 A4.7u/50V R180 22k AG SPMUTE TP330 +5V C142 A4.7u/50V TP332

TP300

TP305

R162

3.3K

TP301

TP304

R179 3.3k

SP OUT
5
TP334 IC13 NJM2113M R184 0R

C N4

TP322 TP318 +5V +5V

1 2
B2B-PH-K-S

C136

R175 1.6k

C139

13 14 15 12 1 5 2 4 X0 X1 X2 X3 X4 X5 X6 X7 VDD
C137 0.1uF

16 VDD 16

R161 R163 R160 R165 R157 R164 R159

5.1k 10k 18K 33K 62K 100K 200K

TP311 TP312 TP313 TP310 TP303 TP306 TP302 TP307

13 14 15 12 1 5 2 4 X0 X1 X2 X3 X4 X5 X6 X7 INH A B C VEE VSS 7 8


CD4051BCSJ

4700pF TP316

2200pF

6 11 10 9 INH A B C VEE VSS 7 8


CD4051BCSJ AG AG AG

6 11 10 9

AG

AG

+5V

R167 4.7k TP315 +5V

R169 4.7k

AG

VOLCNT_A

4. 7k

R158

R156

4. 7k R155

4. 7k

VOLCNT_B

VOL_A

TP314

VOL_B

TP309

VOL_C

TP308

AR-FX13 CIRCUIT DIAGRAM 7 - 8


+5V V ref R177 1k Z D6 HZ2C1 C140 A4.7u/50V AG AG G ND AG

FAX MAIN PWB (SRAM & FLASHROM (16M)) (Europe, Australia, New Zealand)

3/6

D[7:0]

A[21:0] A0

D
IC10 IC 9

I/O7 I/O6 I/O5 I/O4 I/O3 I/O2 I/O1 I/O0

29 28 27 26 25 23 22 21

D7 D6 D5 D4 D3 D2 D1 D0

NC
BAT

A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0

10 7 11 4 12 1 31 2 3 13 14 15 16 17 18 19 20 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 9


A17 TP203 TP204 TP205 TP206 TP207 TP208 TP209 D7 D6 D5 D4 D3 D2 D1 D0 F _ R YB Y TP108 +3.3V C99 0.1uF

DQ15 DQ14 DQ13 DQ12 DQ11 DQ10 DQ9 DQ8 DQ7 DQ6 DQ5 DQ4 DQ3 DQ2 DQ1 DQ0 RY/BY BYTE VPP VCC 13 37 15 47

45 43 41 39 36 34 32 30 44 42 40 38 35 33 31 29

VCC
C76 0.1uF + TP325 F_WP CS_FL RESETL C75 100pF A21 MBM29LV160BE90TN R100 75 G ND TP117 C77 47u/25V

CS_S0L CS_S1L

A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1

9 16 17 48 1 2 3 4 5 6 7 8 18 19 20 21 22 23 24 25 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0

30 6 32 5 CE1 CE2 OE WE VSS 24


IS62WV1288BLL G ND

26 12 28 11 14 10 CE RP OE WE WP NC GND GND 27 46

C
G ND OEL WEL

+3.3V

BAT TP83 R81 10k RTC_DATA RTC_CLK TP89 TP88 RTC_CE0H TP86 TP85

+3.3V

IC 6 C61 C60

7 6 5 1

DATA CLK CE I/OSM8578BV

VDD XTXT VSS

8
12pF 12pF

+3.3V CN2002 L_BTTP329

BAT

3 2 4
C65 F0.1u/16V R87 10k X2 DT-38 32.768KHz

R47 560

TP78 TP20 C_BT TP253

G ND

Q7 KTA1504 G ND

TP77

CS_S1L

R68 1k

G ND

AR-FX13 CIRCUIT DIAGRAM 7 - 9


1 2
B2B-PH-K-S IC 4

Z D4 UDZ2.0B

Q6 KTA1504

TP82

TP79

R44 20k

R48 360 TP22

B
VCC
PST3426

R45 1k

C40 0.1uF

D4 1SS355

1 OUT NC 3 TP2 GND 2

G ND

B
G ND G ND

TP81 G ND R25 100k

TP80

R24 1k

Q8 KTC3875

R69 1k

G ND

BT1 HL50-A

JP3

0R

Q1 DTC363EKA C B

G ND

G ND

G ND

+3.3V

FAX MAIN PWB (MN195006Q) (Europe, Australia, New Zealand)


MDM3.3V

4/6

D
+3.3V +3.3V MDM3.3V C98 A47u/25V F L7 FL10 F L6 F L5 F L2 F L8 FL14 F L9 F L4 F L3 +3.3V G ND

C28 A22u/16V +1.8V TP67

C39 A47u/25V

G ND +3.3V

+3.3V

R61

4.7k

MDM_IRQ C LKIN R59 33 MDM3.3V G ND MDM3.3V R58 33 X1 SCO10-24.576000MHz-3.3V TP57 3 OUT OE 1 FB2001 ACH32(N.M.)

TP75

R62

0R

TP72

C55 0.1uF C57 0.1uF C35 0.1uF C48 0.1uF C51 0.1uF C53 0.1uF C29 A22u/16V C30 0.1uF C31 0.1uF

C
34 92 78 68 44 30 15 3 55 54 97 86 62 42 21 9 53 52
G ND

C33 0.1uF C34 1uF(1608) C54 0.1uF C52 0.1uF C50 1uF(1608) C32 1uF(1608) C36 0.1uF C38 0.1uF C56 0.1uF C49 1uF(1608)

2 GND
C69 C470/16V C70 F0.1u/16V

IC 5

VDD

FL13 ZJSR5101(22000p)

VDD3 VDD3 VDD3 VDD3 VDD3 VDD3 VDD3

VDD2 VDD2 VDD2 VDD2 VDD2 VDD2

1 T3IRQ
TP61 R57 47K TP60

AVDD

VDDREG VDDREG

CS_ML OEL WEL TP45 TP49

MDM3.3V

R37 R38

47K 47K

75 74 73 71 72 NDPCS NDPRD NDPWR NUB NLB NRESET


TP66 TP58 MCLOCK C LKIN C N1 G ND +3.3V G ND +3.3V R2004 C164 10pF 33(N.M.) R26 75

REGOUT REGOUT

NDBGREQ DBGMOD PLLON TMS TCK TDI TDO

26 27 36 33 31 29 28

TP59

G ND

G ND

M_RESETL

41 CXIN CXOUT CLKOUT CNT LON SCANNT MINTEST INTEST MODE0 MODE1
MN195006E

C47 100pF

39 38 43 37 51 45 46 48 49 50 57 58
G ND TP37 TP38 TP41 TP39 R33 0R

G ND

A[21:0]

A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0

100 98 96 95 94 93 91 90 88 87 85 84 DPA11 DPA10 DPA09 DPA08 DPA07 DPA06 DPA05 DPA04 DPA03 DPA02 DPA01 DPA00 EYECLK EYEDAT 1 2 3 4 5 6
A2-6PA-2.54DSA(NM)

R28 47K

R29 47K

R31 47K R13 R30 R12 100 100 100 TP28 TP47 TP43 TP26 ABITCLK ASPCLK ATXD ARXD

AVSS

35

G ND R43 R67 47K 0R TP27 AFERST_L

99 89 80 70 64 56 47 40 32 23 17 11 5

VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS

AR-FX13 CIRCUIT DIAGRAM 7 - 10


ABITCLK ASPCLK ATXD ARXD
MDM3.3V

D[7:0]

MNR04 33 8 7 6 5 BR7 1 2 3 4

59 60 63 61

8 7 6 5 BBITCLK BSPCLK BTXD BRXD


G ND TP50 TP51 TP70 TP71 TP69 TP68 MDM3.3V R63 R66 47K 47K

B
GPIO0 GPIO1 GPIO2 GPIO3 GPIO4 GPIO5 76 77 79 81 82 83
R41 R42 R64 47K 47K 47K

MDM3.3V

MNR04 33

65 66 69 67

TP48 TP44 TP46 TP42

R34 R35 R40 R36

47k 47k 47k 47k

R32 47K

B
G ND

BR1 TP242 D7 1 TP239 D6 2 TP212 D5 3 TP211 D4 4 TP220 D3 TP218 D2 TP216 D1 TP214 D0 R97 47K R98 47K R99 47K R101 47K R102 47K R103 47K R104 47K R60 47K TP63 25 TP62 24 TP64 22 TP65 20 TP101 19 TP102 18 TP103 16 TP104 14 TP105 13 TP107 12 TP109 10 TP111 8 TP113 7 TP115 6 TP116 4 TP73 2

DPD15 DPD14 DPD13 DPD12 DPD11 DPD10 DPD09 DPD08 DPD07 DPD06 DPD05 DPD04 DPD03 DPD02 DPD01 DPD00

G ND

FAX MAIN PWB (ASIC_NEW_CILF) (Europe, Australia, New Zealand)


D [7:0] A[21:0] MCU_D[7:0] PB_A[7:0] PB_D[7:0]

5/6

D
PB_D0 PB_D1 PB_D2 PB_D3 PB_D4 PB_D5 PB_D6 PB_D7 FL17 IC 8 C83 F0.1u/16V TP183 TP181 G ND MCU_INT MCU_CEL MCU_OEL FL12 C82 F0.1u/16V G ND (N.M.) +3.3V (N.M.) +3.3V

BR17 MNR04 47 1 8 2 7 3 6 4 5

1 BR16 2 MNR04 47 3 4

8 7 6 5

+3.3V

BR24

TP189 TP184 TP185 TP177 TP186 TP178

BR21 PB_CS1L PB_AE0L PB_WEL PB_OEL

1 2 3 4
TP187 TP269 TP191 TP190 TP171 TP172 TP173 TP168 BR5 MNR04 1 2 3 4 M CU_D0 M CU_D1 M CU_D2 M CU_D3 0R 8 7 6 5 BR3

8 7 6 5

MNR04 22K +3.3V R108 +3.3V MNR04 0R WEL +3.3V C84 F0.1u/16V RESETL G ND TP268 RGDTTP262 TP261 FL18 (N.M.) 10K TP176

1 2 3 4

8 7 6 5

BR22

MNR04 22K

PB_A7 PB_A6 PB_A5 PB_A4 PB_A3 PB_A2 PB_A1 PB_A0 TP169 TP170 TP166 TP167

FL11 C81 F0.1u/16V G ND

(N.M.)

+3.3V

BR23

1 2 3 4

8 7 6 5

1 2 3 4

8 M CU_D4 7 M CU_D5 6 M CU_D6 5 M CU_D7

1 2 3 4
10K 10K 10K 10K

8 7 6 5

MNR04 (N.M.)

C
D8 DA204U R138 R144 R143 TP267 TP266 +3.3V C107 F0.1u/16V R136 G ND R135 TP256 TP254 TP331 C_BT L_BTTP252 10K R132 S +3.3V FL22 (N.M.) 100 BZ TP251 TP328 TP249 R134 G ND M_RESETL 10K TP258 TP257 10K TP255 uPD65 9 44GM-P07-JED-A FL19 (N.M.) 10K 10K 10K BR2 9 MNR04 10K 1 8 2 7 3 6 4 5

MNR04 (N.M.)

C
+3.3V R76 TP161

BR6

R109 R145 R110 R111

22K 22K 22K 22K

TP165 R86 TP90 R83 TP164 R84 TP162 R82 TP163 RTC_CE0H RTC_CLK RTC_DATA CS_S0L CS_FL

1 2 3 4

8 7 6 5

MNR04 10K

10K(N.M.) CS_OP1L TP159 CS_OP2L TP158 TP157 TP156 TP155 TP154 R79 R74 R72 R71 0R A21 C64 18pF FL16 R107 100 C80 F0.1u/16V BR13 G ND (N.M.) +3.3V C62 18pF C59 18pF 100 100 100 CS_ML OEL WEL

BR26 MNR04 10K 1 8 2 7 3 6 4 5

JP2

R70 R106

10K 10K

T2B-SQ

BR 9

1 2 3 4

8 7 6 5 BR8 MNR04 10K

G ND

1 2 3 4 5 6 7 BR18 8 MNR04 0R 1 9 8 10 2 7 11 6 3 12 5 4 13 1 8 14 2 7 15 3 6 16 4 5 BR1 9 MNR04 0R 17 18 19 20 21 22 23 R114 33 24 W AKE_UP 25 26 27 28 EXHKD_L 29 30 31 HS2_L 32 CID_L 33 HS1_L 34 35 F _ R YB Y 36 37 R140 10K TP263 38 TP260 39 R142 10K 40 VDD PB_DAT_05 PB_DAT_04 PB_DAT_03 PB_DAT_02 PB_DAT_01 PB_DAT_00 TESTMODE0 PB_ADDR_07 PB_ADDR_06 PB_ADDR_05 PB_ADDR_04 PB_ADDR_03 PB_ADDR_02 PB_ADDR_01 PB_ADDR_00 PB_CE2_N PB_CE1_N PB_AE0_N VDD GND PB_WR_N PB_OE_N RESET_N WAKE_UP FGPI_07 FGPI_06 FGPI_05 FGPI_04 FGPI_03 FGPI_02 FGPI_01 FGPI_00 FGPIO_07 FGPIO_06 FGPIO_05 FGPIO_04 TCK TRST VDD GND GND PB_DAT_06 PB_DAT_07 CPU_INT_N CPU_CS_N CPU_RD_N VDD GND CPU_DT_00 CPU_DT_01 CPU_DT_02 CPU_DT_03 GND CPU_DT_04 CPU_DT_05 CPU_DT_06 CPU_DT_07 VDD GND FAXWRIN_N UART_RTS UART_CTS UART_SOUT UART_SIN RTC_ION RTC_CE RTC_SCLK RTC_SDATA FAXCS_N_00 FAXCS_N_01 FAXCS_N_02 FAXCS_N_03 FAXCS_N_04 FAXCS_N_05 FAXOE_N FAXWR_N FAXADD_21 GND GND

160 159 158 157 156 155 154 153 152 151 150 149 148 147 146 145 144 143 142 141 140 139 138 137 136 135 134 133 132 131 130 129 128 127 126 125 124 123 122 121

1 2 3 4

8 7 6 5

BR10

MNR04 10K

BR30 MNR04 10K 1 8 2 7 3 6 4 5

G ND

BR11

1 2 3 4

8 7 6 5

MNR04 10K

TP135 TP145 TP136 TP146 TP137 TP147 TP138

BR12 MNR04 100 1 8 2 7 3 6 4 5

A20 A19 A18 A17 A16

1 2 3 4

8 7 6 5

BR25

MNR04 10K

1 2 3 4

8 7 6 5

PB_D7 TP273 PB_D6 TP278 PB_D5 TP274 PB_D4 TP279 PB_D3 TP275 PB_D2 TP280 PB_D1 TP276 PB_D0 TP281 PB_A7 TP195 PB_A6 TP179 PB_A5 TP180 PB_A4 TP192 PB_A3 TP193 PB_A2 TP182 PB_A1 TP188 PB_A0 TP194 PB_CS1L PB_AE0L PB_WEL PB_OEL D7 D6 D5 D4 D3 D2 D1 D0 A21 TP106 A20 TP112 A19 TP110 A18 TP114 A17 TP127 A16 TP134 A15 TP121 A14 TP125 A13 TP130 A12 TP131 A11 TP122 A10 TP124 A9 TP129 A8 TP132 A7 TP123 A6 TP126 A5 TP128 A4 TP133 A3 TP213 A2 TP215 A1 TP217 A0 TP219

1 2 3 4

MNR04 10K

FL15 C79 F0.1u/16V

(N.M.)

+3.3V

AR-FX13 CIRCUIT DIAGRAM 7 - 11


TP148 TP139 TP152 TP149 TP140 TP141 TP153 TP142 TP150 TP143 TP246 TP243 TP244 TP245 C106 F0.1u/16V SPMUTE TP327 G ND +3.3V C105 F0.1u/16V TP237 G ND FL21 (N.M.) F_WP VOL_C VOL_B VOL_A VOLCNT_B VOLCNT_A D7 R131 D6 R130 100 TP241 100 TP240

BR2

1 8 2 7 3 6 BR14 4 5 8 7 MNR04 100 6 5 BR15 1 8 MNR04 1002 7 3 6 4 5

A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4

BR4

1 2 3 4

8 7 6 5

+3.3V G ND

B
+ C109 A47u/25V +3.3V +3.3V R126 TP223 TP235 TP234 R124 10K G ND C101 100pF 10K R122 10K R127 10K(N.M.) +3.3V G ND

1 2 3 4

8 7 6 5

MNR04 (N.M.)

M CU_D7 M CU_D6 M CU_D5 M CU_D4 M CU_D3 MNR04 (N.M.) M CU_D2 M CU_D1 M CU_D0 R90 22K M CU_INT R89 22K TP290 MCU_CEL R88 22K TP294 MCU_OEL

R85 R75

10K 10K

WEL OEL

TP119 TP118

MNR04 100 BR27 TP151 1 A3 8 TP144 2 A2 7 TP231 3 A1 6 TP224 4 BR28 A0 5 TP228 D0 1 8 TP225 MNR04 100 2 D1 7 TP229 D2 3 6 TP226 D3 4 5 TP221 R120 100 D4 TP222 R121 100 MNR04 100 D5 TP227 R125 0R(N.M.) TP233 TP230

R78 R77 R80 R139

10K 10K 10K 10K

C S_FL TP160 CS_ML TP76 CS_S0L TP87 F _ R YB Y TP259

41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 GND GND TMS NC TDI TDO FGPIO_03 FGPIO_02 FGPIO_01 FGPIO_00 TELELIN BEEP_O_V1 BEEP_O_V2 FGPO_15 FGPO_14 FGPO_13 FGPO_12 GND FGPO_11 FGPO_10 FGPO_09 FGPO_08 GND VDD FGPO_07 FGPO_06 FGPO_05 FGPO_04 FGPO_03 FGPO_02 FGPO_01 FGPO_00 FAX_DATA_07 FAX_DATA_06 VDD GND XIN XOUT GND GND

VDD FAXADD_20 FAXADD_19 FAXADD_18 FAXADD_17 FAXADD_16 FAXADD_15 FAXADD_14 GND FAXADD_13 FAXADD_12 FAXADD_11 FAXADD_10 FAXADD_09 FAXADD_08 FAXADD_07 FAXADD_06 FAXADD_05 FAXADD_04 GND VDD FAXADD_03 FAXADD_02 FAXADD_01 FAXADD_00 FAX_DATA_00 FAX_DATA_01 FAX_DATA_02 FAX_DATA_03 FAX_DATA_04 FAX_DATA_05 TMD0_OUT TOUT TESTB TMD2 TMD1 TMD0 SYSCLK_IN CLKSEL VDD

120 119 118 117 116 115 114 113 112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81

R137 R141

7.5k 10k

R123 10K

TP264

C ID_L EXHKD_L

G ND

FL20

(N.M.)

+3.3V

G ND

G ND

R146 R133 +3.3V

22K 10K

TP270 TP250

RESETL M_RESETL TP238 C103 F0.1u/16V

C102 A47u/25V

G ND IC 7 C LKIN R95 TP99 C73 F0.1u/16V G ND G ND TP98 C72 270pF 510 TP95 TP96 TP97 R2001 0R C71 F0.1u/16V TP232 R128 0R C104 100pF TP236 R129 75 G ND G ND

A
1 2 3 4 Xin Xout S1 LF
P2782A-08SR

A
8 7 6 5

G ND

VDD S0 FSOUT VSS

FAX MAIN PWB (MCU I/F) (Europe, Australia, New Zealand)


R112 R149 TP5V LC3S-Y(N.M.) ZJSR5101(22000p) FL25 ZJSR5101(22000p) FL24 TP24V LC3S-Y(N.M.) ZJSR5101(22000p) FL23 0R 100

6/6
4 3 2 1
C92 A47u/35V + FB2002 ACH32(N.M.) #MDM_IRQ #RESET#PB_nOE #PB_nWE #PB_nAE0 #PB_nCS1 +3.3V TP3.3V LC3S-Y(N.M.) IN3.3V +5V IN5V +24V IN24V

MDM_IRQ RESETL PB_OEL PB_WEL PB_AE0L PB_CS1L

5 6 7 8 5 6 7 8
33pF 33pF 100pF 33pF FB3 MNR04 33 + FB2004 ACH32(N.M.) + FB2003 ACH32(N.M.)

4 3 2 1

TP348 TP343 TP347 TP342

D
10p/50V 1000pF D7 C 85 C 87 C116 C117 C118 C120 A47u/25V C 90 F0.1u/16V C 89 1000p(N.M.) C 88 F0.1u/16V C 93 A47u/25V C 94

BR20 MNR04 0R

1SS355(N.M.)

G ND G ND G ND G ND G ND

G ND

G ND

PB_A[7:0]

FB4 MNR04 5 6 7 8 33 4 3 2 1 CN2001

PB_A0 PB_A1 PB_A2 PB_A3 PB_A4 PB_A5 PB_A6 PB_A7

TP346 TP341 TP345 TP340 TP344 TP339 TP282 TP277

5 6 7 8
33pF 33pF 33pF 33pF 33pF 33pF 33pF 33pF FB7 MNR04 33

4 3 2 1

#PB_A0 #PB_A1 #PB_A2 #PB_A3 #PB_A4 #PB_A5 #PB_A6 #PB_A7

40

C112

C113

C114

C11 9 C115

C146

C147

C148

C
G ND

IN5V #MDM_IRQ #PB_nOE #PB_nAE0 #PB_A0 #PB_A2 #PB_A4 #PB_A6 #PB_D0 #PB_D2 #PB_D4 #PB_D6 #MCU_INT #MCU_nOE #MCU_D1 #MCU_D3 #MCU_D5 #MCU_D7

39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1
IN3.3V IN 24V #RESET#PB_nWE #PB_nCS1 #PB_A1 #PB_A3 #PB_A5 #PB_A7 #PB_D1 #PB_D3 #PB_D5 #PB_D7 #MCU_nCS #MCU_D0 #MCU_D2 #MCU_D4 #MCU_D6 B40B-PNDZS-1

40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2

PB_D[7:0] 33 4 3 2 1 #PB_D0 #PB_D1 #PB_D2 #PB_D3 #PB_D4 #PB_D5 #PB_D6 #PB_D7

PB_D0 PB_D1 PB_D2 PB_D3 PB_D4 PB_D5 PB_D6 PB_D7

FB8 MNR04 5 6 7 8

G ND

5 6 7 8
33pF 33pF 33pF 33pF 33pF 33pF 33pF 33pF FB9 MNR04 33

4 3 2 1

C155

C14 9 C150

C151

C156

C152

C153

C154

+3.3V C9 0.1uF G ND TP56 R9 22 G ND

+3.3V C10 0.1uF TP298 R27 22 G ND

+3.3V C25 0.1uF TP1 R21 22 G ND

+3.3V C26 0.1uF TP35 R22 22 G ND

+3.3V C27 0.1uF TP55 R23 22 G ND

+3.3V C37 0.1uF TP52 R39 22 G ND

+3.3V C41 0.1uF TP53 R50 22 G ND

+3.3V C43 0.1uF TP54 R51 22

10p/50V

10p/50V

10p/50V

C121

C122

C123

10p/50V(N.M.)

10p/50V(N.M.)

10p/50V(N.M.)

10p/50V(N.M.)

10p/50V(N.M.)

10p/50V(N.M.)

10p/50V(N.M.)

10p/50V(N.M.)

C124

C125

C126

C128

C127

C157

C158

G ND

C160

AR-FX13 CIRCUIT DIAGRAM 7 - 12


+3.3V #MCU_INT #MCU_nCS #MCU_nOE C45 0.1uF TP93 R55 22 G ND FB5 MNR04 TP289 5 6 7 8 47 4 TP283 3 2 1 +3.3V G ND C86 0.1uF R113 22 FB6 MNR04 5 6 7 8 100 4 3 2 1 G ND +3.3V

B
G ND +3.3V C46 0.1uF TP94 R56 22 G ND +3.3V C58 0.1uF TP74 R65 22 G ND +3.3V C63 0.1uF TP84 R73 22 G ND +3.3V C66 0.1uF TP91 R93 22 G ND +3.3V C67 0.1uF TP92 R94 22 G ND +3.3V C74 0.1uF TP100 R96 22 G ND +3.3V C78 0.1uF TP120 R105 22 G ND

MCU_INT MCU_CEL MCU_OEL

R150 R151

0R 0R

TP295 TP288 TP284

+3.3V C91 0.1uF TP196 TP198 R115 22 G ND

+3.3V C95 0.1uF TP200 R116 22 G ND

+3.3V C96 0.1uF TP201 R117 22 G ND

+3.3V C97 0.1uF TP202 R118 22 G ND

+3.3V C100 0.1uF TP210 R119 22 G ND

+3.3V C108 0.1uF TP335 R181 22 G ND

+3.3V C110 0.1uF TP271 R147 22 G ND

MCU_D[7:0]

+3.3V

+3.3V

+3.3V

+3.3V

+3.3V

+3.3V

+3.3V

M CU_D0 M CU_D1 M CU_D2 M CU_D3 M CU_D4 M CU_D5 M CU_D6 M CU_D7

TP287 TP293 TP292 TP286 TP285 TP291 TP199 TP197

5 6 7 8

4 3 2 1
FB10 MNR04 100

#MCU_D0 #MCU_D1 #MCU_D2 #MCU_D3 #MCU_D4 #MCU_D5 #MCU_D6 #MCU_D7

C111 0.1uF TP272 R148 22 G ND

C129 0.1uF TP296 R152 22 G ND

C130 0.1uF TP297 R153 22 G ND

C131 0.1uF TP299 R154 22 G ND

C141 0.1uF TP326 R178 22 G ND

C159 0.1uF TP337 R185 22 G ND

C161 0.1uF TP349 R186 22 G ND

C162 0.1uF TP350 R187 22 G ND

FAX OPERATION PWB

1/1
4
D401

CN401

1SS133 KEY418 KEY417 KEY416 KEY415 KEY414 KEY413

KEY412

S/SK OT6K
SKQNABD010 SKQNABD010 SKQNABD010 SKQNABD010 SKQNABD010

OT4K CONTK 2SIDEK OT9K

OT5K
SKQNABD010

D402

SKQNABD010

3. FAX OPERATION

1SS133

KEY408

KEY407

KEY406

KEY405

KEY404

KEY403

KEY402

BCK
D403 LED401 SKQNABD010 SKQNABD010 SKQNABD010 SKQNABD010 SKQNABD010

OT7K OT2K REPK

CSK

OT8K
SKQNABD010

R/PK
SKQNABD010

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

F-KEYSC3 F-KEYSC2 F-KEYSC1 F-KEYIN7 F-KEYIN6 F-KEYIN5 F-KEYIN4 F-KEYIN2 F-KEYIN3 F-KEYIN1 LED_V3 LED_V2 LED_V1 DATA1 TP1

BM15B-GHS-TBT LTL-1LHG-002A

LSL
1SS133 KEY411 KEY410 KEY421 KEY420 KEY419

KEY409

KEY401

MEMK SPKK
SKQNABD010 SKQNABD010 SKQNABD010 SKQNABD010

OT1K

OT3K

RESOK
SKQNABD010

SFTK
SKQNABD010

RMODK
SKQNABD010

3
LED403

SFTL
LTL-1LHG-002A

LED402

MEML
LTL-1LHG-002A

AR-FX13 CIRCUIT DIAGRAM 7 - 13


B C

LEAD-FREE SOLDER
The PWBs of this model employs lead-free solder. The LF marks indicated on the PWBs and the Service Manual mean Lead-Free solder. The alphabet following the LF mark shows the kind of lead-free solder.

Example:
<Solder composition code of lead-free solder> Solder composition code (Refer to the table at the right.) Solder composition Sn-Ag-Cu Sn-Ag-Bi Sn-Ag-Bi-Cu Sn-Zn-Bi Sn-In-Ag-Bi Sn-Cu-Ni Sn-Ag-Sb Bi-Sn-Ag-P Bi-Sn-Ag Solder composition code a b z i n s p

Lead-Free

5mm

(1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD


When repairing a lead-free solder PWB, use lead-free solder thread. Never use conventional lead solder thread, which may cause a breakdown or an accident. Since the melting point of lead-free solder thread is about 40C higher than that of conventional lead solder thread, the use of the exclusive-use soldering iron is recommendable.

(2) NOTE FOR SOLDERING WORK


Since the melting point of lead-free solder is about 220C, which is about 40C higher than that of conventional lead solder, and its soldering capacity is inferior to conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land separation or may exceed the heat-resistive temperature of components. Use enough care to separate the soldering iron from the PWB when completion of soldering is confirmed. Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently. If different-kind solder remains on the soldering iron tip, it is melted together with lead-free solder. To avoid this, clean the soldering iron tip after completion of soldering work. If the soldering iron tip is discolored black during soldering work, clean and file the tip with steel wool or a fine filer.

CAUTION FOR BATTERY REPLACEMENT


(Danish) ADVARSEL ! Lithiumbatteri Eksplosionsfare ved fejlagtig hndtering. Udskiftning m kun ske med batteri af samme fabrikat og type. Levr det brugte batteri tilbage til leverandoren. (English) Caution ! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to manufacturers instructions. (Finnish) VAROITUS Paristo voi rjht, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hvit kytetty paristo valmistajan ohjeiden mukaisesti. (French) ATTENTION Il y a danger dexplosion s il y a remplacement incorrect de la batterie. Remplacer uniquement avec une batterie du mme type ou dun type quivalent recommand par le constructeur. Mettre au rebut les batteries usages conformment aux instructions du fabricant. (Swedish) VARNING Explosionsfara vid felaktigt batteribyte. Anvnd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera anvnt batteri enligt fabrikantens instruktion.

(German) Achtung Explosionsgefahr bei Verwendung inkorrekter Batterien. Als Ersatzbatterien drfen nur Batterien vom gleichen Typ oder vom Hersteller empfohlene Batterien verwendet werden. Entsorgung der gebrauchten Batterien nur nach den vom Hersteller angegebenen Anweisungen.

CAUTION FOR BATTERY DISPOSAL


(For USA, CANADA) "BATTERY DISPOSAL" THIS PRODUCT CONTAINS A LITHIUM PRIMARY (MANGANESS DIOXIDE) MEMORY BACK-UP BATTERY THAT MUST BE DISPOSED OF PROPERLY. REMOVE THE BATTERY FROM THE PRODUCT AND CONTACT YOUR LOCAL ENVIRONMENTAL AGENCIES FOR INFORMATION ON RECYCLING AND DISPOSAL OPTIONS. "TRAITEMENT DES PILES USAGES" CE PRODUIT CONTIENT UNE PILE DE SAUVEGARDE DE MMOIRE LITHIUM PRIMAIRE (DIOXYDE DE MANGANSE) QUI DOIT TRE TRAITE CORRECTEMENT. ENLEVEZ LA PILE DU PRODUIT ET PRENEZ CONTACT AVEC VOTRE AGENCE ENVIRONNEMENTALE LOCALE POUR DES INFORMATIONS SUR LES MTHODES DE RECYCLAGE ET DE TRAITEMENT.

COPYRIGHT 2008 BY SHARP CORPORATION


All rights reserved. Printed in Japan. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic; mechanical; photocopying; recording or otherwise without prior written permission of the publisher.

Trademark acknowledgements
Microsoft, Windows, Windows 98, Windows Me, Windows 2000, Windows XP, Windows Vista and Internet Explorer are registered trademarks or trademarks of Microsoft Corporation in the U.S.A. and other countries. Adobe, the Adobe logo, Acrobat, the Adobe PDF logo, and ReaderTM are registered trademarks or trademarks of Adobe Systems Incorporated in the United States and other countries. IBM, PC/AT, and PowerPC are trademarks of International Business Machines Corporation. Sharpdesk is a trademark of Sharp Corporation. All other trademarks and copyrights are the property of their respective owners.

SHARP CORPORATION Digital Document System Group CS Promotion Center Yamatokoriyama, Nara 639-1186, Japan
2008 April Printed in Japan

Вам также может понравиться