[1] PRODUCT OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 [2] SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 [3] INSTALLATION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 [4] SIMULATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 [5] FAX SOFT SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 [6] TROUBLE CODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 [7] CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 PARTS GUIDE
Parts marked with are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.
SHARP CORPORATION
This document has been published to be used for after sales service only. The contents are subject to change without notice.
[2] SPECIFICATIONS
Large item Middle item Communication Electronic system transmission system Small item Electronic transmission time Compression/ Extraction system MODEM speed Mutual communication Used line R-key operation when setting PBX PBX setting Used line number Connection form Sub item Specifications Less than 3 sec (Super G3 mode, 33600bps) Less than 7 sec (G3 ECM mode, 14400bps) MH, MR, MMR, JBIG 33600bps - 2400bps (Automatic fall-back) Super G3/G3 Public switched telephone network (PSTN), Private branch exchange (PBX) Yes (Germany only) Yes (Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway) 1 line For 1 line of telephone; FAX machine External telephone Yes Specifying the destination number Resolution Density Transmission start time Polling receive Cover addition setting Send document scan system Auto send function to a predetermined telephone number Max. 50 digits One-touch key Max. 18 items Max. 40 digits Max. 20 characters 0 - 3 characters Max. speed: 33600bps/ High speed: 14400bps/ Middle speed: 9600bps/ Low speed: 4800bps NO/ Mode 1/ Mode 2/ Mode 3 One-touch dial key
Transmission functions
Transmission operation
ECM Items which can be selected and registered by user when transmitting
Auto send function Application send function Chain dial Rapid key dial
Registration key Number of items Number of digits of destination number Destinationregistration name Retrieval characters Communication start speed International communication mode Transmission method
Group dial
Sub item Number of items Number of digit of destination number Destination registration name Retrieval characters Communication start speed International communication mode Transmission method Registration key Number of groups which can be registered Destination registration name Number of stations which can be registered in one group Numbers which can be registered Retrieval characters Transmission method Retrieval target
Specifications 100 items (Reduction number 00 - 99) 40 digits 20 characters 0 - 3 characters Max. speed: 33600bps/ High speed: 14400bps/ Meddle speed: 9600bps/ Low speed: 4800bps NO/ Mode 1/ Mode 2/ Mode 3 Speed dial key + (00 - 99) + Start key One-touch dial key 18 items (One-touch dial + Group dial) 20 characters Max. 100 stations in one group (Max. total items which can be registered: 150 items) Destination numbers registered in one-touch dial and speed dial, 10-key dial 0 - 3 characters Group dial key Speed dial One-touch dial Group dial SEARCH key 0 - 3 characters Inch series: 8.5" AB series: 210mm 500mm (Only from RSPF, with user support) RSPF: Single surface scan AB series: A4 Inch series: Letter (8.5" x 11")/Legal (8.5" x 14") (Default: Letter (8.5" x 11")) Yes 256 gradations Manual 5 steps Standard/Fine/Super Fine/Fine + Half-tone/Super Fine + Half-tone (Default: Standard) Light/Medium/Dark Scan density Standard: 8dot x 3.85 line/mm Fine: 8dot x 7.7 line/mm Super Fine: 8dot x 15.4 line/mm Half-tone: Scan in 256 gradations Book document scan/send function from the document table (OC). In one send job, the send document size is fixed.
Send functions
Document size
Retrieval key Retrieval character Max. document width Max. document length Send document size
AR-FX13 SPECIFICATIONS 2 - 1
Middle item Small item Send document Sender registration/ information adding send function function Send header function Page counter function Cover adding function
Send message adding function Index function Direct send function Memory send function
Long document send function Manual send function Time specifying send function
Sub item Specifications Sender telephone 20 digits number Sender registration 36 characters name Header display content Sender number registered in sender registration/ Sender name/ Send date and time/ page Adding position Top right (The right edge) Adding form P. XXX (Max. 999) Display items Date and time Destination name (Max. 20 characters) Destination number (Max. 40 digits) Sender name (Max. 20 characters) Sender number (Max. 20 digits) Send quantity (3 digits) Send message (When send message adding function is used) Fixed message NO MESSAGE/CONFIDENTIAL/PLS. DISTRIBUTE/ URGENT/PLS. CALL BACK/IMPORTANT Yes (Max. 10 kinds in printable area) Yes Send form Send reservation Number of items of Time specifying send send reservation Group send Serial broadcast Max. 52 items (excluding redial) Group send and broadcast are treated as one item. Operation when Document scan stop memory full Memory full display Job continuation check Job continuation: Scanned document data are sent. Job stop: Scanned document data are deleted. In either case, document is held in RSPF and not discharged. Valid when memory mode is ON. Scan of send document data and send are performed together. When busy tone Redial is performed according to the setting of detected "Number/interval of redial when busy." When no response Redial is performed according to the setting of (CED/ FSK signal are "Number/ interval of resend in communication error." not detected) Communication error Supports up to 500mm. When this length is exceeded, "PAPER JAM" occurs. This function allows to switch to FAX manually when off-hook with document set. Available Memory send, Polling, serial broadcast, serial send communication request Number of set items Max. 5 items Set range 00:00 - 23:59 (Unit: 1 min) Day of week 8 kinds (From Monday to Sunday, and no specification) A message is sent sequentially to two or more destinations registered in group dial. (Max. 52 destinations can be registered in one group.) Broadcast send Max. 100 items destination Valid only in duplex support models. Direct send and scan from OC cannot be made. Send document size A4/ Letter/ Legal size
AR-FX13 SPECIFICATIONS 2 - 2
Middle item Small item Incoming detection Call signal detection function function Remote select function by CNG detection Application Distinctive Ringing incoming function function
Sub item
Specifications Call bell is distinguished from net call signals to judge incoming. Receive is started when CNG signal is detected in standby with external telephone used. (North America) Conforms to the call distinguishing function provided by the local telephone company. (Europe, Australia, New Zealand) Only distinction of TEL/FAX (When FAX distinction of ON/OFF) (Default: OFF) OFF/STANDARD/Pattern 1 - 5 (North America) Incoming is rejected when remaining memory capacity is less than 7%. OFF/LOW/MIDDLE/HIGH OFF/LOW/MIDDLE/HIGH Follows setting on the main unit. Junk stations are registered to be rejected. Max. 10 items Auto (AUTO) Manual (MAN.) Answering machine (A.M.) The line is switched to FAX by detection of call signal. (receive standby mode) AUTO: 0 - 9 times (Default: 2 times) No During Simulation by serviceman Insufficient memory capacity During menu During memory status display Receive is manually started. 0 - 9 times (Default: 0 times) Receive data are accumulated in memory, and outputted when output conditions are satisfied. Countermeasure against print inhibit state. No recording paper Recording paper jam During copy/print job During printing by printer Cover open Paper empty, size error No
Call bell pattern Incoming reject function Call sound volume adjustment function Alarm sound volume adjustment function Key sound volume setting Junk FAX protection function Receive functions system Receive function Receive standby mode
Number of registrations
Auto receive function Number of calls Tel/FAX auto select Incoming reject conditions
Number of calls
Forcible memory receive function Overtake output No function Receive document Auto reduction/ divided Auto reduction function When the reference line number is in the specified output function receive function range. Divided receive When the reference line number exceeds the function specified range. Polling receive The remote machine must be provided with polling function (Send request function. Communication is allowed with an other function) company machine. Sequential send Polling is made to two or more specified destinations. request (Polling) Number of items of destination registration: Max. 100 communication items Remote send Scanned document data in memory are sent automatically by send request from the remote machine. Protection function Check by sender number Check by allow number
AR-FX13 SPECIFICATIONS 2 - 3
Sub item Recordable size Recording paper setting Paper feed Recording paper size detection Recording paper empty detection
Specifications A4/8.5" x 11"/8.5" x 14" AUTO/TRAY 1/TRAY 2 (When the option installed) (In AUTO, TRAY1 has priority.) (Default: AUTO) (North America) Paper feed by tray (Excluding multi manual feed) The recording paper length is detected. If the size differs, a paper size error occurs. Detected by a paper pickup error. Available only in the duplex function support models. Receive data are transferred to the registered station. 1 item 40 digits Countermeasures against an error Paper jam No toner cartridge No toner During toner supply Toner empty No recording paper Yes 50 digits End 20 digits Yes (Fixed to 2sec) Yes (Set by soft switch) Select number (1 digit) + [**] (0 - 9)
Duplex receive Transfer function Number of registered transfer destination Registered telephone number Local transfer
Main unit On-hook dial function telephone function Manual redial function Pause function Pulse/Tone select function External telephone Select function by DTMF connection function Report list Report output function
Report select
TIMER LIST ACTIVITY REPORT TELEPHONE# LIST GROUP LIST PASSCODE LIST JUNK FAX# LIST USER PROGRAM LIST Auto print for every 50 items of send/receive total. Send report list Receive report list Serial broadcast send report list Image memory addition ALWAYS PRINTS ERROR ONLY NEVER PRINTS
AR-FX13 SPECIFICATIONS 2 - 4
Data storage area/ backup when service interruption (Recorded Data other than image data, receive data) Treatment when memory full Quick online
Memory send
Memory status check function Memory content check function Document jam Simulation function Counter function
Others
Environmental functions
Auto clear
Flash memory (Data are retained when the power is turned off or when the battery is exhausted.) SRAM (Data are retained when the power is turned off, but deleted when the battery is exhausted with the power OFF.) Memory full on the first Send cancel without call-out page Memory full on the The line is shut-off after sending the last page of second or later page scanned data. Memory full on the first Send cancel page Memory full on the Send/Cancel is selected depending on the select second or later page menu display. Send: The line is shut off after sending the scanned data. Cancel: Cancel even scanned data. Yes (The remaining memory capacity (%) is displayed on the LCD.) Not-sent job is displayed on the LCD. (Cancel is possible.) Error LED, LCD message are displayed. Send/receive of specified signals, commands, and image data are performed without a remote machine. Communication Number of send pages counter Number of receive pages Number of output pages Send time Receive time Conforms to the main unit setting. When the operation is left for 1 min or more, the display returns to the main menu. Conforms to the main unit setting. (North America) Month/ Day/ Year/ Day of week/ O'clock/ minute (Europe, Australia, New Zealand) Day/ Month/ Year/ Day of week/ O'clock/ minute STANDARD/FINE/SUPER FINE 3SEC/1SEC/NO BEEP
Sub item Standard memory Option Document quantity to be stored Image data
Image priority function BEEP LENGTH (Communication end sound length) setting Auto summer time setting
(North America) Second Sunday of March AM2:00 3:00, First Sunday of November AM2:00 1:00 (Default: OFF) (Europe) Last Sunday of March AM1:00 2:00, Last Sunday of October AM1:00 0:00 (Default: ON) (Australia, New Zealand) Last Sunday of October AM2:00 3:00, Last Sunday of March AM3:00 2:00 (Default: ON) Conforms to the main unit setting.
AR-FX13 SPECIFICATIONS 2 - 5
1. Parts included
1 2
Speaker unit: 1
FAX keyboard: 1
Ground angle: 1
Line cable: 1
Gasket: 2
Screws (M3x6): 5
Screws (M3x6): 6
Core: 1
Operation Manual: 1
3) Attach the sponge around the bent portion of the FFC cable as shown in the figure.
Remove all pieces of fixing tape and fixing materials from the finisher.
2. Installation procedure
(1) Detach the RSPF or OC.
Detach the RSPF or OC from the copier and softly place it on top of the original table as shown below.
4) Align the top frame portion of the FAX modem PWB with the screw hole at the back of the speaker unit. 5) Place the holes of the bottom portion of the FAX modem PWB onto the loosely tightened screws. Slide the PWB to left to secure as shown below. 6) When RSPF is installed, secure the RSPF ground terminal and the FAX modem PWB onto the copier using the screw removed earlier in (4)-1). When OC is installed, secure the FAX modem PWB onto the copier using a supplied screw. 7) Secure the FAX modem PWB onto the copier using a supplied screw. 8) Tighten two loosely tightened screws completely. 9) Secure the ground angle using a supplied screw.
7 4
2) Reattach the rear cabinet shielding plate and secure it using one screw removed earlier. Reattach the RSPF detached in Step (1).
1 5
Ground angle
Speaker connector
Cable
Netherlands (01111011) Luxembourg (01101001) Belgium (00001111) Australia (00001001) New Zealand (01111110) 3) Only for U.K., France, Netherlands, Belgium, Luxembourg, set the FAX soft SW67-1 to 0.
4 3
Putting standard
Putting standard
Insert the power plug of the copier to the outlet and turn on the main switch of the copier. Then, carry out the following procedure. AR-FX13 INSTALLATION PROCEDURE 3 - 3
[4] SIMULATION
1. Entering the simulation mode
To enter the serviceman simulation mode, press the keys as follows: [#] key [] key [Clear] key [] key To cancel the simulation mode, press the [Clear All] key.
2. Key rule
[Numeric] key: Entry of MAIN CODE/SUB CODE Selection of an item Setup of an adjustment value in case of simulations for adjustment [ ][ ] key: Selection of MAIN CODE/SUB CODE Selection of an item [ENTER]/[OK]/[START] key: Settlement <In case of simulations for print> [ENTER]/[OK] key: Settlement (Without print) [START] key: Settlement/Print [Clear] key: (Interrupting operation check) Returns to the upper hierarchy. In case of simulation of operation check, terminates the operations. [Clear All] key: Exits from the simulation mode. For a simulation of adjustment, the display returns to the initial display (00-00).
3. List of simulations
Main code 22 24 46 Sub code 11 10 12 13 14 15 39 66 01 02 03 04 05 07 FAX counter clear Density adjustment in the FAX mode (Collective adjustment) FAX mode density adjustment (Normal text) FAX mode density adjustment (Fine text) FAX mode density adjustment (Super fine) FAX mode sharpness adjustment FAX soft SW setting FAX soft SW initializing (excluding the adjustment values) FAX PWB memory check Signal send mode (Max. value) Signal send mode (Soft SW set value) Image memory content print Contents FAX-related counter display Main code 66 Sub code 10 11 12 13 17 18 21 24 30 33 34 37 38 Contents Image memory content clear 300bps signal send (Max. value) 300bps signal send (Soft SW set value) Dial test DTMF signal send (Max. value) DTMF signal send (Soft SW set value) FAX information print FAST SRAM clear TEL/LIU status change check Signal detection check Communication time measurement Speaker sound volume setting Time setting/check
AR-FX13 SIMULATION 4 - 1
[Function] When [ENTER]/[OK]/[START] key is pressed, the FAX count value is set to 0 and "000,000" is displayed on the LCD. [Operation] 1) Initial display 24-10 FAX CLR. CLEARED 000,000
46
12
[Function] When [START] key is pressed, scan is executed with the entered exposure adjustment value and the data stored on the FAX side is rewritten into the entered value. All data of the exposure adjustment values are rewritten into the same value. For the density adjustment table data, refer to SIM46-13 (density adjustment (Normal text) in the FAX mode). [Operation] 1) Initial display ADJUST EXP. AUTO XX 3) Press [START] key. Scan is started (self print), and the LED of [START] key is turned off. ADJUST SCAN EXP. AUTO YY
("XX" is the exposure adjustment value of normal text stored on the FAX side.) 2) Enter a 2-digit value as the exposure adjustment value with [Numeric] key. ADJUST EXP. AUTO YY
AR-FX13 SIMULATION 4 - 2
Main code 46
Sub code 13
Details of function/operation [Function] Scan is started with the exposure adjustment value entered with [START] key, and the stored data of the selected mode on the FAX side is rewritten into the input value. Density adjustment value data table Mode STD (Normal text) Fine (Fine text) Sfine (Super fine) Photo off on off on off Exposure adjustment value
When initializing each data: 50 [Operation] 1) Initial display ADJUST EXP. STD XX 3) Press [START] key. Scan is started (self print), and the LED of [START] key is turned off. ADJUST SCAN EXP. STD YY
("XX" is the corresponding exposure adjustment value of normal text mode stored on the FAX side.) 2) Enter a 2-digit value as the exposure adjustment value with [Numeric] key. ADJUST EXP. STD YY
("YY" is the entered exposure adjustment value.) 14 FAX mode density adjustment (Fine text) [Function] When [START] key is pressed, scan is started with the entered exposure adjustment value and the data of the selected mode on the FAX side is changed to the entered value. For the density adjustment value table data, refer to SIM46-13 (FAX mode density adjustment (Normal text).) [Operation] 1) Initial display ADJUST EXP. FINE XX 3) Press [START] key. Scan start (self print) ADJUST SCAN EXP. FINE YY
("XX" is the corresponding exposure adjustment value of the fine text mode stored on the FAX side.) 2) Enter a 2-digit value as the exposure adjustment value with [Numeric] key. ADJUST EXP. FINE YY
("YY" is the entered exposure adjustment value.) 15 FAX mode density adjustment (Super fine) [Function] When [START] key is pressed, scan is started with the entered exposure adjustment value and the data of the selected mode on the FAX side is changed to the entered value. For the density adjustment value table data, refer to SIM46-13 (FAX mode density adjustment (Normal text).) [Operation] 1) Initial display ADJUST EXP. S-FINE XX 3) Press [START] key. Scan start (self print) ADJUST SCAN EXP. S-FINE YY
("XX" is the corresponding exposure adjustment value of the super fine mode stored on the FAX side.) 2) Enter a 2-digit value as the exposure adjustment value with [Numeric] key. ADJUST EXP. S-FINE YY
Main code 46
Sub code 39
Details of function/operation [Function] When [START] key is pressed, scan is started with the entered sharpness adjustment value, and the data of the selected mode stored on the FAX side is changed to the entered value. Sharpness adjustment value data table 1: 2: 3: 4: 5: Mode STD FINE S-FINE FINE/PHOTO S-FINE/PHOTO Sharpness adjustment value
When initializing each data: 1 [Operation] 1) Initial display SHARPNESS SETTING PRESS , 2) [ ][ ] key or after 2sec Every time when [ ] key is pressed, the second line is changed in the sequence of No. 1 2 3 4 5 1. When [ ] key is pressed, the sequence is reversed. SHARPNESS SET (1-5) 1:STD 3) Select the arrow key 1-5, and the LED of [START] key is lighted. SHARPNESS SETTING ZZZZ(0-2) X ("ZZZZ" is the mode selected among STD, FINE, S-FINE, FINE/PHOTO, and S-FINE/ PHOTO.) ("X" is the corresponding sharpness adjustment value of the selected mode stored on the FAX side.) [Clear] key: Returns to 2) display. 66 01 FAX soft SW setting [Function] Use to check the FAX soft SW setting. Every time when the key is pressed, the bit on the first line is switched 0 and 1. [Operation] 1) Initial display ENTER FAX SOFT SW. # (3 DIGITS) SW.___ [Clear] key: Returns to the main-sub code input display. 2) Enter a 3-digit value of soft SW No. (To enter the fourth digit, shift to the left.), and the press [ENTER]/[OK] key. No.### CHANGE? xxxxxxxx 1:YES 2:NO 3) Select 1 No.### xxxxxxxx USE # KEY 12345678 4) Change with 1-8 of [Numeric] key and the press [ENTER]/[OK] key. No.### STORED? xxxxxxxx 1:YES 2:NO 4) Enter a one-digit value (0-2) as the sharpness adjustment value with [Numeric] key. SHARPNESS SETTING ZZZZ(0-2) Y ("Y" is the entered sharpness adjustment value.) [Clear] key: Returns to 2) display. 5) Press [START] key. Scan start (self print) SHARPNESS SETTING SCAN Y 6) Print start (self print) SHARPNESS SETTING PRINT Y After completion of printing, returns to 4) display.
"xxxxxxxx" is the set content. Select 2: Returns to the soft SW No. entry display. 5) Select 1 STORED After 2sec, returns to "1) Initial display".
"xxxxxxxx" is the set content. Select 2: Returns to the soft SW No. entry display.
02
[Function] Use to initializing FAX soft SW. [Operation] 1) Initial display INITIALIZED After 2sec, main code and sub code input display. AR-FX13 SIMULATION 4 - 4
Main code 66
Sub code 03
Details of function/operation [Function] Use to check the FAX PWB memory. [Operation] 1) Initial display SELECT CHECK MEMORY PRESS , 2) [ ][ ] key or after 2sec ] key is pressed, the second line is changed in the sequence of No. 1 2
] key is pressed, the sequence is reversed. SELECT MEMORY (1-3) 2:SRAM SELECT MEMORY (1-3) 3:FLASH
[Clear] key: Returns to the main-sub code input display. 3) [ENTER]/[OK] key CHECKING MEMORY 4) After completion of check When the result is OK MEMORY CHECK RESULT OK In case of sum check error MEMORY CHECK RESULT XXXXXXXX SUM NG In case of address bus check error MEMORY CHECK RESULT XXXXXXXX A-BUS NG In case of data check error MEMORY CHECK RESULT XXXXXXXX DATA NG In case of data bus check error MEMORY CHECK RESULT XXXXXXXX D-BUS NG In case of erase check error MEMORY CHECK RESULT XXXXXXXX ERASE NG
[Clear] key: Returns to "1) Initial display". 04 Signal send mode (Max. value) [Function] Use to set the signal send mode (Max. value). Facsimile simulation design specifications. 1 2 3 4 5 6 7 8 9 10 11 12 NO SIGNAL 33600bps(V34) 31200bps(V34) 28800bps(V34) 26400bps(V34) 24000bps(V34) 21600bps(V34) 19200bps(V34) 16800bps(V34) 14400bps(V34) 12000bps(V34) 9600bps(V34) 13 14 15 16 17 18 19 20 21 22 23 24 7200bps(V34) 4800bps(V34) 2400bps(V34) 14400bps(V33) 12000bps(V33) 14400bps(V17) 12000bps(V17) 9600bps(V17) 7200bps(V17) 9600bps(V29) 7200bps(V29) 4800bps(V27ter) 25 26 27 28 29 30 31 32 33 34 35 2400bps(V27ter) 300bps(FLAG) 2100Hz(CED) 1100Hz(CNG) 300bps(V21) 2100Hz(ANSam) DUMMY RING NO VOICE ANSWER NO RING BACK TONE LINE OFF HOOK LINE ON HOOK
[Operation] 1) Initial display SELECT OUTPUT SIGNAL (2 DIGITS) No.___ 2) 2-digit (1-35) with [Numeric] key / [ Pressing [ No. (1-35) 1:NO SIGNAL ] key or [ ..... ][ ] key / 2sec after
[Clear] key: Returns to the main-sub code input display. 3) [ENTER]/[OK] key Send after setting OUTPUTING SIGNAL MAX PRESS CLEAR TO STOP [Clear] key: Returns to "1) Initial display".
AR-FX13 SIMULATION 4 - 5
Main code 66
Sub code 05
Details of function/operation [Function] Use to set the signal send mode (Soft SW set value). Facsimile simulation design specifications. 1 2 3 4 5 6 7 8 9 10 11 12 NO SIGNAL 33600bps(V34) 31200bps(V34) 28800bps(V34) 26400bps(V34) 24000bps(V34) 21600bps(V34) 19200bps(V34) 16800bps(V34) 14400bps(V34) 12000bps(V34) 9600bps(V34) 13 14 15 16 17 18 19 20 21 22 23 24 7200bps(V34) 4800bps(V34) 2400bps(V34) 14400bps(V33) 12000bps(V33) 14400bps(V17) 12000bps(V17) 9600bps(V17) 7200bps(V17) 9600bps(V29) 7200bps(V29) 4800bps(V27ter) 25 26 27 28 29 30 31 32 33 34 35 2400bps(V27ter) 300bps(FLAG) 2100Hz(CED) 1100Hz(CNG) 300bps(V21) 2100Hz(ANSam) DUMMY RING NO VOICE ANSWER NO RING BACK TONE LINE OFF HOOK LINE ON HOOK
[Operation] 1) Initial display SELECT OUTPUT SIGNAL (2 DIGITS) No.___ 2) 2-digit (1-35) with [Numeric] key / [ Pressing [ No. (1-35) 1:NO SIGNAL ] key or [ ..... ][ ] key / 2sec after ] key reverses the sequence. No. (1-35) 35:LINE ON HOOK
[Clear] key: Returns to the main-sub code input display. 3) [ENTER]/[OK] key: Send after setting OUTPUTING SIGNAL SSW PRESS CLEAR TO STOP [Clear] key: Returns to "1) Initial display". 07 Image memory content print [Function] Use to print the image memory content. [Operation] When print is allowed PRINT STORED After completion of printing, main code and sub code input display. 10 Image memory content clear When there is no print data NO DATA After 2 sec, FAX control is terminated. When print is inhibited CAN NOT PRINT After 2 sec, main code and sub code input display.
[Function] Use to clear the image memory content. [Operation] When there are some print data CLEAR IMAGE MEMORY After completion of memory clear, the buzzer sounds. CLEARED PLEASE POWER OFF Remains unchanged until the power is turned off. When there are no print data CLEAR IMAGE MEMORY After completion of memory clear CLEARED After 2sec, main code and sub code input display.
AR-FX13 SIMULATION 4 - 6
Main code 66
Sub code 11
Details of function/operation [Function] Use to set the 300bps signal send (Max. value). 1: 2: 3: 4: 5: 6: NO SIGNAL 11111 11110 00000 010101 00001
[Operation] 1) Initial display SELECT SIGNAL PRESS , 2) [ ][ ] key or after 2sec Every time when [ ] key is pressed, the second line is changed in the sequence of No. 1 2 3 4 5 6 1. When [ ] key is pressed, the sequence is reversed. ..... SELECT SIGNAL (1-6) 6:00001 SELECT SIGNAL (1-6) 1:NO SIGNAL 3) [ENTER]/[OK] key OUTPUTING SIGNAL MAX PRESS CLEAR TO STOP [Clear] key: Returns to "1) Initial display". 12 300bps signal send (Soft SW set value) [Function] Use to set the 300bps signal send (Soft SW set value). 1: 2: 3: 4: 5: 6: NO SIGNAL 11111 11110 00000 010101 00001
[Operation] 1) Initial display SELECT SIGNAL PRESS , 2) [ ][ ] key or after 2sec Every time when [ ] key is pressed, the second line is changed in the sequence of No. 1 2 3 4 5 6 1. When [ ] key is pressed, the sequence is reversed. ..... SELECT SIGNAL (1-6) 6:00001 SELECT SIGNAL (1-6) 1:NO SIGNAL 3) [ENTER]/[OK] key OUTPUTING SIGNAL SSW PRESS CLEAR TO STOP [Clear] key: Returns to "1) Initial display".
AR-FX13 SIMULATION 4 - 7
Main code 66
Sub code 13
Contents Dial test [Function] Use to the dial test. [Operation] Dial test (PULSE) 1) Initial display SELECT SIGNAL 1:PULSE 2:DTMF
Details of function/operation
Dial test (DTMF) 1) Initial display SELECT SIGNAL 1:PULSE 2:DTMF [Clear] key: Returns to the main-sub code input display. 2) __ Select 2 SELECT HIGH LEVEL 1:DEFAULT 2:SOFT SW. 3) Select 1 Select 2 __
[Clear] key: Returns to the main-sub code input display. 2) Select 1 INPUT MAKE TIME (0-15)
3) Enter the make time in 2 digits. INPUT DIAL # XXXX XXXX: Default After deleting with [Clear] key, input can be made. 4) [ENTER]/[OK] key SEND yyPPS xxms 1:YES 2:NO "yy" is the selected pulse 10 or 20. "xx" is the input value. Select 2: Returns to 2) display. 5) Select 1 Switched to 10/20PPS set with pulse selection inside. 6) After setting SENDING yyPPS xxms 7) After completion of sending TERMINATE ? 1:YES 2:NO Select 2: Returns to 4) display. 8) Select 1 TERMINATED After 2sec, returns to "1) Initial display". 4) Select 1 INPUT DIAL # XXXX XXXX: Default
After deleting with [Clear] key, input can be made. 4) [ENTER]/[OK] key H:xx 1:YES 2:NO L:yy
"xx" indicates HI, and "yy" indicates Low Soft SW. Select 2: Returns to 4) display. 5) Select 1 HI/LO is selected with the signal level inside. 6) After setting the signal send level SENDING DTMF 7) After completion of sending TERMINATE ? 1:YES 2:NO Select 2: Returns to 4) display. 8) Select 1 TERMINATED After 2sec, returns to "1) Initial display".
17
[Function] Use to set the DTMF signal send (Max. value). [Operation] 1) Initial display INPUT DIAL # [Clear] key: Returns to the main-sub code input display. 2) [Numeric] key input The content selected with signal send level selection is set inside. 3) Communication is started after setting the signal send level. SENDING SIGNAL MAX PRESS CLEAR TO STOP [Clear] key: Returns to "1) Initial display".
AR-FX13 SIMULATION 4 - 8
Main code 66
Sub code 18
Details of function/operation [Function] Use to set the DTMF signal send (Soft SW set value). [Operation] 1) Initial display INPUT DIAL # 3) Communication is started after setting the signal send level. SENDING SIGNAL SSW PRESS CLEAR TO STOP
[Clear] key: Returns to the main-sub code input display. [Clear] key: Returns to "1) Initial display". 2) [Numeric] key input The content selected with signal send level selection is set inside. 21 FAX information print [Function] Use to print the FAX information. [Operation] 1) Initial display SELECT REPORT (1-3) PRESS , 2) [ ][ ] key or after 2sec ] key is pressed, the second line is changed in the sequence of 1 2 3
] key is pressed, the sequence is reversed. SELECT REPORT (1-3) 2:SOFT SW. LIST SELECT REPORT (1-3) 3:PROTOCOL
SELECT REPORT (1-3) 1:USER SW. LIST 3) [ENTER]/[OK] key When print is allowed PRINT STORED After completion of printing, main code and sub code input display. 24 FAST SRAM clear [Function] Use to clear the FAST SRAM. [Operation] 1) Initial display CLEAR FAST SRAM
[Clear] key: Returns to the main-sub code input display. When print is inhibited CAN NOT PRINT After 2sec, FAX control is terminated.
2) After completion of clearing CLEARED After 2sec, main code and sub code input display.
30
[Function] Use to check the TEL/LIU status change. [Operation] 1) Initial display HS2 :xxx RHS :xxx HS1 :xxx EXHS:xxx The display is switched every 2sec. CHECKING PRESS CLEAR TO STOP [Clear] key: Returns to the main-sub code input display.
AR-FX13 SIMULATION 4 - 9
Main code 66
Sub code 33
Contents Signal detection check [Function] Use to check the signal detection. [Operation] 1) Initial display CHECKING NONE PRESS CLEAR TO STOP
Details of function/operation
When a signal is detected, the display is changed from NONE to the following. CI/CNG/CED/BT/DT/Flag/SDT/DTMF [Clear] key: Returns to the main-sub code input display. 34 Communication time measurement [Function] Use to measurement the communication time. [Operation] 1) Initial display COMM. TIME xx:xx:xx:xxx msec "xx:xx:xx:xxx" indicates o'clock, minute, second, millisecond. [Clear] key: Returns to the main-sub code input display. 37 Speaker sound volume setting [Function] Use to set the speaker sound volume. 1: 2: 3: 4: NO SOUND LOW MID HIGH
[Operation] 1) Initial display SELECT SPEEKER VOL. PRESS , 2) [ ][ ] key or after 2sec ] key is pressed, the second line is changed in the sequence of 1 2 3 Every time when [ 4 1. When [ SELECT (1-4) 1:NO SOUND 3) [ENTER]/[OK] key STORED xxx xxx: Set content After 2sec, main code and sub code input display.
AR-FX13 SIMULATION 4 - 10
Main code 66
Sub code 38
Contents Time setting/check [Function] Use to check the time setting. [Operation] 1) Initial display SELECT TO SET 1:DATE 2:TIME
Details of function/operation
[Clear] key: Returns to the main-sub code input display. 2) Select 1 xxxx.xx.xx(xxx) CHANGE? 1:YES 2:NO "xxxx.xx.xx(xxx)" is the current value. (No revision of display) 3) Select 1 INPUT YEAR (4 DIGITS)____.__.__ Select 2: Returns to "1) Initial display". 4) Enter the year in 4 digits. INPUT MONTH (1-12) 1998.__.__ 5) Enter the month in 2 digits. INPUT DAY (1-31) 1998.01.__ 6) Enter the day in 2 digits. xxxx.xx.xx(xxx) STORED? 1:YES 2:NO "xxxx.xx.xx(xxx) is the entered value. Select 2: Returns to "1) Initial display". 7) Select 1 STORED After 2sec, returns to "1) Initial display". After 2sec, returns to "1) Initial display". 2) Select 2 xx:xx CHANGE? 1:YES 2:NO
Select 2: Returns to "1) Initial display". 4) Enter o'clock in 2 digits. INPUT MINUTE (00-59) 01:__
"xx:xx" is the current value. Select 2: Returns to "1) Initial display". 6) Select 1 STORED
AR-FX13 SIMULATION 4 - 11
S W 1
3 4
S W 2
6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7
Inhibited to use
5 6 7 8 0 to 9
0 0 0 0 0 0 1 1 1 1 1 1
Refer to User program RESO.PRIORITY. When a value outside 0 the set range is set, the initial value is set. 0 Manual reception can be set only when 0 external telephone is connected. Refer to User program 0 SECURITY SELECTION. 0 0 0 0 0 0 0 0 Refer to User program 1 REMOTE RECEPTION #. 0 When a value outside the set range is set, 1 the initial value is set.
1 1 0 0
2 0 0 0
3 0 1 0
4 0 0 0
5 0 0 1
S W 3
1 2
Bit No. Centimeter size Conforms to the machine information. Inch size Conforms to the machine information. Binary input Bit No. Set range
7 8 0 0 0 1 1 0 1 1
0 When a value outside 0 the set range is set, Medium 1 the initial value is set. 0 0 1 When set to conformity to the 0 0 0 0 0 0 0 machine information, Conforms to the if machine information machine is uncertain, set to information. centimeter size. 1 1 1 1 1 1 1 Refer to User program RECALL INTERVAL (LINE ERROR). When a value outside the set range is set, the initial value is set. For the New Zealand models, tough it is set to 0, recall is performed in an interval of 1min. Refer to User program RECALL INTERVAL (BUSY). When a value outside the set range is set, the initial value is set.
0 0 1 0 0 0
0 0 1 0 0 0
0 0 1 0 0 1
0 0 1 0 0 1
0 0 1 0 0 1
0 0 1 0 0 1
0 0 0 0 0 0 0
0 0 0 0 0 0 0
3 S W 4
1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3min 1 1 1 1 1 1 1 1 1 1 1 1 1 1
5 6 7 8 1 to 15min
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 3 S W 5 Item Inhibited to use G3 send data accumulation wait time Bit No. 6sec 5sec 4sec 3sec Binary input Bit No. Set range 1: 1: 1: 1: Yes Yes Yes 2 times 3 0 0 1 1 4 0 1 0 1 Switch selection and contents of functions Initial value A B C D E F G 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6sec 0 0 0 0 0 0 0 0 0 1 0 1 1 1 0 0 1 0 1 1 1 0 0 1 0 1 1 1 0 0 1 0 1 1 1 0 0 1 0 1 1 1 0 0 1 0 1 1 1 0 When a value outside 0 the set range is set, 1 the initial value is set. 0 1 1 1 Remark
5 6 7 8 1 to 15sec
2sec
5 6 S W 6 7
2 3 4 5
ECM CED signal send CSI transmission DIS reception confirmation in G3 send Inhibited to use EOL detection timer Countermeasure for echo in reception (CED tone send interval) Countermeasure for echo in transmission (After reception of DIS, hold time up to signal send is set.) Dial tone ON/OFF detection time lower limit (Intermittent detection) Dial tone detection Busy tone detection Dial tone monitoring time Dial tone ON/OFF detection time upper limit (Intermittent detection) Max. length of reception Destination display time when one-touch key is pressed
1: 25sec 1: 500ms
0: No Yes 0: No Yes 0: No Yes 0: Once in NFS reception, Once in NFS 2 time in DIS reception reception, 2 time 0 0 0 0 0 0 0 in DIS reception 0 0 0 0 0 0 0 0: 13sec 13sec 0 0 0 0 0 0 0 0: 75ms 500ms
1 1 1 1 1 1 1
1: 800ms
0: 500ms 500ms 0 0 0 0 0 0 0
1: 300ms
0: 100ms 100ms 0 0 0 0 0 0 0
0: No 0: No 0: 5sec 0: 700ms
S W 7
700ms
0 0 0 0 0 0 0
6 7 8 1 S W 8
1.5m
0 0 0 0 0 0 0 0 0 0 0 0 0 0 When a value outside the set range is set, the initial value is set.
2sec 0 0 0 0 0 0 0
2 3 4
Memory transmission/ direct transmission default setup Proxy reception 1: Yes Inhibited to use Quick online send 1: Yes
0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 5 S W 8 Item Remote select function 1: Yes Switch selection and contents of functions 0: No Yes Binary input Bit No. Set range 1: Yes 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 0 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 When a value outside 0 the set range is set, 0 the initial value is set. 0 0 1 Initial value A B C D E F G Remark Refer to User program REMOTE RECEPTION SELECT. When a value outside the set range is set, the initial value is set.
6 7 8 1
Number of times of CNG detection Print of total communication time and total pages Inhibited to use Ringing volume pattern number
6 7 8 1 to 4 times 0: No
3 times
Yes
S W 9
2 3 4 5 6 7 8 1
3 4 5 6 7 8 Pattern No. 1 to 35
7 (A/B) 1 (C/D/E/F/G)
2 S W 10
S W 11
3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3
Measurement of 1: Yes communication time (image) Senders 1: Inhibit telephone number registration Inhibited to use
0: No Yes 0: Allow Allow 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 1 0 0 0 1 0 0 0 0 0 0 0 0 0 1 1 0 1 0 0 0 1 0 0 0 0 0 0 0 0 0 1 1 0 1 0 0 0 1 0 0 0 0 0 0 0 0 0 1 1 0 1 0 0 0 1 0 0 0 0 0 0 0 0 0 1 1 0 1 0 0 0 1 0 0 0 0 0 0 0 0 0 1 1 0 1 0 0 When a value outside 0 the set range is set, 1 the initial value is set. 1 1 1 1 1 1 1
1: 64 [bytes/frame]
0: 256 [bytes/frame]
Call time setup in automatic transmission (T0 timer setup) Inhibited to use CI detection
S W 12
1 1 1 1 1 1 1 0 0 0 0 0 0 0 When a value outside the set range is set, the initial value is set.
0 0 0 0 0 0 0 4 sine wave 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Inhibited to use Inhibited to use Ringing volume Bit No. Silent Small Medium Large 3 0 0 1 1 4 0 1 0 1
S W 13
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 5 S W 13 Item Speaker volume in DTMF send Switch selection and contents of functions Bit No. Not used Small Medium Large 5 0 0 1 1 6 0 1 0 1 Initial value A B C D E F G 1 1 1 1 1 1 1 Medium 0 0 0 0 0 0 0 1 1 0 1 0 1 0 0 0 0 1: 350ms 0: 250ms 250ms 1: 650ms 0: 750ms 0 0 0 0 0 0 0 1 1 0 1 0 1 0 0 0 0 1 1 0 1 0 1 0 0 0 0 1 1 0 1 0 1 0 0 0 0 1 1 0 1 0 1 0 0 0 0 1 1 0 1 0 1 0 0 0 0 1 1 0 1 0 1 0 0 0 0 Remark
S W 14
S W 15
Busy tone detection time (Lower limit) Busy tone detection time (Upper limit) Busy tone detection time (Lower limit 2) Signal send level
1: 150ms
0: Follows SW15-1.
4 5 6 7 8 1
4 5 6 7 8 0 (0dBm) to 26 (26dBm)
750ms (A/B/C/D/E) 0 0 650ms (F/G) Follows SW15-1. (A/B) 0 0 150ms (C/D/E/F/G) 0 0 12dBm (A/B/G) 1 1 11dBm 1 1 (C/D/E) 0 0 9dBm (F) 0 0
0 0 0 1 1
1 1 1 1 1 0 1 0 1 1 0 1 0 1 1 0 1 0 1 1 0 1 0 0 1 0 When a value outside 1 the set range is set, 1 the initial value is set. 0 0
3 S W 16
6 7 8 1 2 S W 17 3 4 Inhibited to use Inhibited to use MH fixed (Except for SG3) ECM MMR mode (Except for SG3) ECM JBIG mode (Except for SG3)
Bit No. V.27 2400bps V.29 9600bps V.27 4800bps V.29 7200bps V.33 14.4kbps V.33 12.0kbps V.17 9600bps V.17 12.0kbps V.17 7200bps V.17 14.4kbps Bit No. No fixing V.29-9600BPS V.27ter-4800BPS V.17-14400BPS
1 2 3 0 0 0 0 0 0 0 0 1 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 0 1 Others 5 6 0 0 0 1 1 0 1 1
4 0 1 0 1 0 0 1 0 1
1 1 1 1 1 1 1
0 0 0 0 0 0 0 V.17 14.4kbps 0 0 0 0 0 0 0
0 0 0 0 0 0 0
0 0 0 0 0 0 0 No fixing 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
No Yes Yes
0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 5 6 S W 17 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 Item Inhibited to use MH fixed (in SG3) 1: Yes ECM MMR mode (in SG3) ECM JBIG mode (in SG3) Inhibited to use 1: Yes 1: Yes Switch selection and contents of functions Initial value A B C D E F G 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 0 0 0 0 0 1 0 0 0 1: Yes 0: No No 1 1 0 1 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 1 0 0 0 Refer to User program AUTO LISTING. Remark
No Yes Yes
S W 18
Inhibited to use
S W 19
Recording table automatic print Inhibited to use Line sound monitor range
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
S W 20
3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Line monitor display Inhibited to use Receivable memory capacity Inhibited to use
1 2 0 0 0 1 1 0 0: No
0 0 0 0 0 0 0 OFF 0 0 0 0 0 0 0
When a value outside the set range is set, the initial value is set.
No
0 0 0 0 0 0 0 0 0 0 0 0 0 0
1: 64Kbyte
0: 128Kbyte
128Kbyte
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0
S W 21
1 2 3 4 5 6 7 8 0 to 255sec
Inhibited to use
S W 22
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 3 4 5 6 7 8 1 2 3 4 Item Inhibited to use Switch selection and contents of functions Initial value A 0 0 0 0 0 0 0 0 0 0 B 0 0 0 0 0 0 0 0 0 0 C 0 0 0 0 0 0 0 0 0 0 D 0 0 0 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 0 0 0 F 0 0 0 0 0 0 0 0 0 0 G 0 0 0 0 0 0 0 0 0 0 Remark
S W 23
Inhibited to use Specified number reception (ANTI JUNK FAX) Bit No. Not set. Receive inhibit 3 4 0 0 0 1
Not set.
S W 24
5 6
Inhibited to use Document output 1: Collective output after setup in reception completion of reception
Refer to Main menu ANTI JUNK FAX. When a value outside 0 0 0 0 0 0 0 the set range is set, the initial value is set. 0 0 0 0 0 0 0 0 0 0 0 0 0 0
7 8
Inhibited to use Automatic reduction print Automatic reduction rate setup Transmission end sound tone
Output after reception of every page (A/B) Collective output 0 0 1 1 1 1 1 after completion of reception (C/D/E/F/G) 0 0 0 0 0 0 0 Allow Refer to User program 1 1 1 1 1 1 1 AUTO RCV REDUCE. 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 When a value outside 0 0 0 0 0 0 0 the set range is set, the initial value is set. 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1000Hz 1 1 1 1 1 1 1 1sec 0 0 0 0 0 0 0 0 0 0 0 0 0 0 When a value outside the set range is set, the initial value is set.
1: Allow
0: Inhibit
S W 25
1 2 3 4 5 6 7 8 1 2 3
Binary input Bit No. Set range Bit No. 550Hz 1000Hz 1700Hz Bit No. 550Hz 1000Hz 1700Hz 1: Mute
1 2 3 4 0 to 15% 5 0 0 1 7 0 0 1 0: 6 0 1 0 8 0 1 0 1sec
10%
1000Hz
S W 26
3 0 0 1 1
4 0 1 0 1
Small
5 6 7 8
Inhibited to use
Refer to User program 0 0 0 0 0 0 0 BEEPER VOLUME (send completion sound / receive completion sound / 1 1 1 1 1 1 1 scan completion sound / alarm sound) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
SW Data Item NO. No. 1 Inhibited to use 2 3 4 S 5 W 6 27 7 Recording paper tray selection 8
Initial value 0 1 1 1 1 0
Remark
7 0 0 1
8 0 1 0
AUTO
S W 28
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1
Inhibited to use
Number of auto switch calls of Binary input manual reception auto reception Bit No. Set range
0 time
S W 29
Refer to User program TRAY SELECTION. When a value outside 0 the set range is set, the initial value is set. 1 1 0 1 0 0 0 0 0 Refer to User program 0 # OF RINGS MANUAL RX. 0 When a value outside the set range is set, 0 the initial value is set. 0 0 Refer to User program 0 # OF RINGS AUTO RX. 1 When a value outside the set range is set, 0 the initial value is set. 0 0 1 0 1 0 0 1
5 6 7 8 0 to 9 times
2 times
1: Output
0: Not output
Not output
S W 30
Default data, sender print Inhibited to use Date/sender print position setup Inhibited to use Report output (in transmission)
1: ON 1: Inside of document
ON Outside of document
4 S W 31
Bit No. Print inhibited All print Only when transmission is failed. Bit No. Print inhibited All print Only the address to which transmission is failed Bit No. Print inhibited All print Only in error Bit No. Print inhibited All print Only the address to which transmission is failed
1 0 0 1 3 0 0 1
2 0 1 0 4 0 1 0
Refer to User program 1 PRINT SELECTION. When a value outside the set range is set, 0 the initial value is set. Refer to User program 0 PRINT SELECTION. When a value outside the set range is set, the initial value is set. 1
All print
5 0 0 1 7 0 0 1
6 0 1 0 8 0 1 0
Refer to User program 0 PRINT SELECTION. Print inhibited When a value outside the set range is set, 0 the initial value is set. Refer to User program Only the address 1 PRINT SELECTION. When a value outside to which the set range is set, transmission is the initial value is set. failed 0
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 3 S W 32 4 5 6 7 8 1 2 3 4 5 6 7 8 1 Inhibited to use Index print setup Inhibited to use Page number print 1: Yes setup Inhibited to use 0: No Item Distinctive ringing (U.S.A., Canada, Australia, New Zealand) Switch selection and contents of functions Bit No. OFF Standard/ON Pattern 1 *1 Pattern 2 *1 Pattern 3 *1 Pattern 4 *1 Pattern 5 *1 1: Print 1 0 0 1 0 1 0 1 2 0 0 0 1 1 0 0 3 0 0 0 0 0 1 1 4 0 1 0 0 0 0 0 Initial value A B C D E F G 0 0 0 0 0 0 0 Remark
OFF
Refer to User program DISTINCTIVE RING. 0 0 0 0 0 0 0 When a value outside the set range is set, 0 0 0 0 0 0 0 the initial value is set. *1: For U.S.A., Canada only 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0: Not print
Not print
0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0
Yes
S W 33
2 S W 34
3 4 5 6 7 8 1 2 3
Reception data 1: Yes duplex print Flash send wait Bit No. time (U.S.A., 0sec Canada, U.K., 0.5sec Netherlands, 1sec Luxembourg, 2sec Belgium, France, Australia, New Zealand: Inhibited to use) Inhibited to use Signal send level Max. Binary input Bit No. Set range 1: Yes
0: No 1 0 0 1 1 2 0 1 0 1
No
0 0 0 0 0 0 0
0 0 0 1 0 0 0 1sec 0 0 0 0 0 0 0
5 6 7 8 0 (0dBm) to 15 (15dBm) 0: No
8dBm
0 0 1 0 0 0
0 0 1 0 0 0
0 0 1 0 0 0
0 0 1 0 0 0
0 0 1 0 0 0
0 0 1 0 0 0
0 0 1 0 0 0
Cover function default setup Inhibited to use CI delete max. OFF time
No
0 0 0 0 0 0 0 1 1 1 1 1 1 1
S W 35
Bit No. 5sec 10sec 15sec 20sec Binary input Bit No. Set range Binary input Bit No. Set range
3 0 0 1 1
4 0 1 0 1
0 0 0 0 0 0 0
0 0 1 1 1 0 0 5 times (A/B) 6 times (C/D/E/F/G) 0 1 0 1 0 0 1 0 1 1 0 1 0 1 0 1 0 0 1 0 1 1 0 1 0 1 1 0 0 0 1 0 1 1 0 1 0 1 1 0 0 0 1 0 1 1 0 1 0 1 1 0 0 0 1 0 1 1 0 1 0 1 1 0 0 0 1 0 1 1 0 1 0 1 1 0 0 When a value outside 0 the set range is set, 1 the initial value is set. 0 1 1 0 1
5 6 7 8 0 to 15 times
1 2 3 4 5 6 7 8 1 to 255sec 45sec
S W 36
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 3 4 5 6 7 8 1 Item Inhibited to use Switch selection and contents of functions Initial value A 0 1 0 1 0 1 0 1 B 0 1 0 1 0 1 0 1 C 0 1 0 1 0 1 0 1 D 0 1 0 1 0 1 0 1 E 0 1 0 1 0 1 0 1 F 0 1 0 1 0 1 0 1 G 0 1 0 1 0 1 0 1 Remark
S W 37
Protocol monitor
2 3 S W 38 4 5
S W 39
7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2
Protocol monitor save Inhibited to use Flash send time (U.S.A., Canada, U.K., Netherlands, Luxembourg, Belgium, France, Australia, New Zealand: Inhibited to use) Transfer function 1: Inhibited to use Inhibited to use
Bit No. Not output Not output Output Output only in an error 1: Yes
1 0 0 1 1 0:
2 0 1 0 1 No
5 0 0 1 1
6 0 1 0 1
0 0 0 0 0 0 0 90ms 0 0 0 0 0 0 0
Allow
0: Inhibit
Allow
DTMF signal send Binary input time Bit No. Set range
1 0 0 0 1 0
4 5 6 7 8 60 to 310ms (U.S.A., Canada) 70 to 310ms (Europe, Australia, New Zealand) 10ms unit
1 0 0 0 0 0 When a value outside the set range is set, 1 1 1 1 1 1 1 the initial value is set.
1 0 0 0 1 0
1 0 0 0 1 0
1 0 0 0 1 0
1 0 0 0 1 0
1 0 0 0 0 0
S W 40
1 times
Refer to User program RECALL TIMES (LINE ERROR). When a value outside the set range is set, the initial value is set.
S W 41
1 2 3 4 5 6 7 8 0 to 14 times (U.S.A., Canada) 0 to 10 times (Europe) 0 to 9 times (Australia, New Zealand) 0: Allow 0: Inhibit
2 times
Refer to User program RECALL TIMES (BUSY). When a value outside the set range is set, the initial value is set.
S W 42
Direct send recall (U.S.A., Canada) FAX receive auto select by CNG detection
1: Inhibit 1: Allow
Allow Allow
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 3 Item Auto receive select in answering telephone connection mode Inhibited to use Switch selection and contents of functions 1: Allow 0: Inhibit Inhibit 0 0 0 0 0 0 0 Initial value A B C D E F G Remark Refer to Main menu AM MODE.
S W 42
4 5 6 7 8
1 0 0 0 0: OFF ON 0: OFF ON
1 0 0 0
1 0 0 0
1 0 0 0
1 0 0 0
1 0 0 0
1 0 0 0
1 2 3 4 S W 43
V.34 mode 1: ON function in manual communication V.34 mode 1: ON function Inhibited to use V.34 receive symbol speed mask Bit No. 2400 2743 2800 3000 3200 3429
1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1
5 6 7 8 1 2 3 4 5 6 7 8 1 2 Inhibited to use V.34 primary channel send speed V.34 primary channel receive speed
4 0 0 0 0 1 1
5 0 0 1 1 0 0
6 0 1 0 1 0 1
When a value outside 1 1 1 1 1 1 1 the set range is set, the initial value is set. 3429 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0
S W 44
Binary input Bit No. Send speed = 2400 (bps) x N Binary input Bit No. Receive speed = 2400 (bps) x N
1 2 3 4 When N = 0, 2400bps. When N = 15, 33600bps. 5 6 7 8 When N = 0, 2400bps. When N = 15, 33600bps. 0: 2 0 0 1 No 3 0 1 0
33600bps
33600bps
3 S W 45 4
FAST mode 1: Yes Bit No. Sequence of year/ month/day in LCD, Year/Month/Day report, and sender Month/Day/Year record Day/Month/Year Time display format Scan effective image area main scan right edge image loss (RSPF) Specification of print sequence in duplex print Specification of rotating direction duplex back surface print Priority in the day of week 1: am/pm
No
0: 24H
5 6 7 8 1
5 6 7 8 0 to 360 dots 24 dots interval 0: Reception order (123456...) 0: No 180 degrees rotation
Refer to User program Month/Day/Year 0 0 1 1 1 1 1 DATE&TIME (A/B) FORMAT SET. Day/Month/Year When a value outside (C/D/E/F/G) 1 1 0 0 0 0 0 the set range is set, the initial value is set. Refer to User program am/pm (A/B) 1 1 0 0 0 0 0 DATE&TIME 24H (C/D/E/F/G) FORMAT SET. 0 0 0 0 0 0 0 1 1 1 1 1 1 1 96 dots 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Print order (214365...) 180 degrees rotation 1 1 1 1 1 1 1
S W 46
1 1 1 1 1 1 1
1: Yes
0: No
0 0 0 1 1 0 0
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 4 5 S W 46 Item Center No. in FAST mode Summer time Switch selection and contents of functions 1: Host-Tel-No. 1: Allow 0: Service-No. 0: Inhibit Initial value Service-No. Inhibit (A/B) Allow (C/D/E/F/G) A B C D E F G 0 0 0 0 0 0 0 Refer to Entry Mode 0 0 1 1 1 1 1 DAY LIGHT SAVING. Refer to User program 0 0 0 0 0 0 0 PBX SETTING MODE. 0 0 0 0 0 0 0 When a value outside the set range is set, 0 0 0 0 0 0 0 the initial value is set. 0 0 1 1 1 1 1 Yes 0: No Yes 1 1 1 1 1 1 1 0 0 0 1 0 0 Bit No. 10PPS TONE 1 2 0 0 1 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 Remark
6 7 8 1 2
S W 47
3 4 5 6 7 8 1 2
PBX setting (U.S.A., Canada, U.K., Netherlands, Luxembourg, Belgium, Australia, New Zealand: Inhibited to use) Inhibited to use External 1: telephone connection Inhibited to use
6 0 1 1
7 0 0 1
8 0 1 0
Setting OFF
TONE
Refer to User program DIAL MODE. When a value outside 0 0 0 0 0 0 0 the set range is set, the initial value is set. 1 1 1 1 1 1 1 0 0 1 1 1 1 1 0 0 1 0 0 0 1 0 0 0 1 0 0 0 1 0 0 0 1 0 0 0 1 0 1 0 1 0
S W 48
Telephone line menu Inhibited to use Scan effective image area main scan left edge image loss (RSPF) Inhibited to use Speaker sound volume pattern number in DTMF send
1: Inhibit
0: Allow
4 5 6 7 8 1 2 3 4 5 6 7 8 1
96 dots
0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 When a value outside 0 the set range is set, 0 the initial value is set. 0 0 1 When SPEAKER key 1 1 1 1 1 1 1 is pressed, user setting can be made. 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1
S W 49
3 4 5 6 7 8 Pattern No. 1 to 35
Bit No. Silent Small Medium Large Binary input Bit No. Set range
1 0 0 1 1
2 0 1 0 1
Medium
0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 0 0 1 0 1 0 1 0 0 0 0 0 0 1 0 1 When a value outside the set range is set, the initial value is set.
3 4 5 6 7 8 Pattern No. 1 to 35
16
S W 51
DTMF send level Binary input (High group) setup Bit No. Set range
When a value outside the set range is set, the initial value is set.
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 6 S W 51 7 Item CED detection time Busy tone detection cycle Switch selection and contents of functions 1: 500ms Bit No. 2puls 4puls 6puls 10puls Bit No. 43dB 35dB 33dB 30dB 0: 1000ms 7 0 0 1 1 1 0 0 1 1 8 0 1 0 1 2 0 1 0 1 Initial value 1000ms A B C D E F G 0 0 0 0 0 0 0 Remark
0 0 0 0 0 0 0 2puls 0 0 0 0 0 0 0
0 0 0 0 0 0 0 43dB 0 0 0 0 0 0 0 0 0 0 0 0 0 0
2 3 4 S W 52 5 6 7 8
Inhibited to use Super G3 disabled 1: Super G3 enabled in the last call-out of recall in case of an error Error process in 1: Not error RTN reception Inhibited to use V.34 control channel communication speed Maximum DTMF send level 1: 2400bps
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0: 1200bps 1200bps 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0
S W 53
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4
1 2 3 4 0 (0.0dBm) to 15 (15.0dBm) 5 6 7 8 0 (2.0dBm) to 15 (+5.5dBm) 0.5dBm unit When set to 0: Low group = High group (2.0) dBm 1 2 3 4 0 to 240 lines 16 lines interval
0dBm
DTMF send level Binary input (difference Bit No. between high and Set range low level)
0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1 1 0 0 0 0 1 0 1 1 0 1 1 1 0 0 1 0
S W 54
Scan effective image area sub scan lead edge image loss (RSPF) Scan effective image area sub scan rear edge image loss (RSPF) CI signal OFF detection enable time
96 lines
144 lines
S W 55
S W 56
0 0 0 0 0 0 0 0 0 0 0 0 0 0
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 5 S W 56 Item DT/BT detection frequency range Switch selection and contents of functions Bit No. Modem fixed (400Hz) 420Hz680Hz 360Hz440Hz 245Hz650Hz 5 0 0 1 1 6 0 1 0 1 Initial value 245Hz650Hz (A/B/C/D/E/F) 360Hz440Hz (G) A B C D E F G 1 1 1 1 1 1 1 Remark
6 7 8 1 2 Inhibited to use Inhibited to use Sharp machine mode Inhibited to use Reception gain adjustment
1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0
1: ON
0: OFF
ON
1 1 1 1 1 1 1 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0
S W 57
S W 58
3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3
0.0dBm
1600ms
FSK signal Binary input settlement time in Bit No. double wait Set range Inhibited to use Reception SED ON level Bit No. 43dB 38dB 33dB 48dB Bit No. 0dB 4dB 8dB 12dB Bit No. 0dB 4dB 8dB 12dB Binary input Bit No. Set range
550ms
8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
3 0 0 1 1 5 0 0 1 1 7 0 0 1 1
4 0 1 0 1 6 0 1 0 1 8 0 1 0 1
1 1 1 1 1 1 1 48dB 1 1 1 1 1 1 1
0 0 0 0 0 0 0
0 0 0 0 0 1 1
0 0 0 0 0 0 0 0dB 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
S W 60
Scan effective image area sub scan lead edge image loss (RSPF back surface) Scan effective Binary input image area sub Bit No. scan rear edge Set range image loss (RSPF back surface) Inhibited to use
96 lines
144 lines
S W 61
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 3 4 S W 62 Item Inhibited to use Switch selection and contents of functions Initial value A 0 0 0 B 0 0 0 C 0 0 0 D 0 0 0 E 0 0 0 F 0 0 0 G 0 0 0 Remark
5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Inhibited to use
4 0 0 1 1
5 0 1 0 1
0 0 0 0 0 0 0 4sec 1 1 1 1 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0
Inhibited to use
S W 63
Inhibited to use
S W 64
Inhibited to use
S W 65
Inhibited to use
S W 66
S W 67
40ms (A/B) 33ms (C/E) 41ms (D) 31ms (F) 34ms (G)
0 0 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Inhibited to use
SW Data Item NO. No. 1 Line open delay time in dial test
Switch selection and contents of functions Bit No. 2sec 3sec 4sec 5sec 1 0 0 1 1 2 0 1 0 1
Initial value
Remark
0 2sec 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 1 0 0
40sec
Inhibited to use
S W 69
Inhibited to use
1: 4.4sec Bit No. 0.5sec 1.0sec 1.5sec 2.0sec Bit No. 3 times 6 times 9 times 12 times
0: 3.4sec 5 0 0 1 1 7 0 0 1 1 6 0 1 0 1 8 0 1 0 1
3.4sec
0 1.0sec 1
0 3 times 0 0 0 0 0 1 1 0 0
8 1 2 3 4 5 6 7 8 1 2 3 S W 72 4 5 6 7 8 RTC EOL send times Inhibited to use CNG send start Inhibited to use
S W 71
EYE-Q check ERR frame reception operation Waiting time for CED/ANSam send start
1: EYE-Q check only 1: Continues process. Bit No. 2.25sec 3sec 4sec 1: 6 times Bit No. 0.5sec 1.0sec 1.5sec
0 0 0 When a value outside the set range is set, the initial value is set.
When a value outside the set range is set, the initial value is set.
Initial value 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 0
Remark
Print effective image area sub scan Binary input lead edge void Bit No. Set range Inhibited to use
32 lines
Manual calibration setting when 1: ON sending Manual calibration setting when a 1: ON signal arrives Communication end sound (Buzzer Bit No. sound length) setting 3sec 1sec Silent
0: OFF 0: OFF 3 0 0 1 4 0 1 0
OFF OFF
3sec
5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
48 dots
Communication error 0 sound is generated even in silent setup Refer to User program BEEP LENGTH. 0 When a value outside the set range is set, the initial value is set. 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
S W 76
Scan magnification ratio adjustment 1: (main scan) flag Scan magnification ratio adjustment Binary input (RSPF main scan) Bit No. Set range
0%
S W 77
Scan magnification ratio adjustment 1: (sub scan) flag Scan magnification ratio adjustment Binary input (RSPF sub scan) Bit No. Set range
0: +
0%
SW Data Item NO. No. 1 Print magnification ratio adjustment (main scan) flag 2 Print magnification S 3 ratio adjustment W 4 (main scan) 78 5 6 7 8 1 Print magnification ratio adjustment (sub scan) flag 2 Print magnification S 3 ratio adjustment W 4 (sub scan) 79 5 6 7 8 1 Destination information 2 3 4 S W 80 5 6 7
Initial value + 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 1 0 0 0 1 1 0 1 0 0 1 0 1 1 1 1 0 8 1 1 0 0 1 1 0 1 0 0 0 1 0 1 1 0 0
Remark
0%
1:
0: + +
0%
1 2 3 4 5 6 7 8 U.S.A. (10110101) Canada (00100000) U.K. (10110100) Germany (00000100) France (00111101) Sweden (10100101) Spain (10100000) Italy (01011001) Switzerland (10100110) Finland (00111100) Denmark (00110001) Norway (10000010) Netherlands (01111011) Luxembourg (01101001) Belgium (00001111) Australia (00001001) New Zealand (01111110)
U.S.A. Canada U.K. Germany France Sweden Spain Italy Switzerland Finland Denmark Norway Netherlands Luxembourg Belgium Australia New Zealand
1 2 3 4 S W 81 5 6 7
Language information
Binary input Bit No. 0: Japanese 1: American English 2: English 3: French 4: German 5: Italian 6: Dutch 7: Swedish 8: Spanish
1 2 3 4 5 6 7 8 10: Turkish 11: Greek 12: Polish 13: Hungarian 14: Czech 15: Russian 16: Finnish 17: Norwegian 18: Danish 19: Chinese
1 1 0 1 0 0 1 1 0 1 0 0 1 0 0 0 0 0 1 U.S.A.: 1 0 Canada: 1 0 U.K.: 2 0 Germany: 4 0 France: 3 0 Sweden: 7 0 Spain: 8 0 Italy: 5 0 Switzerland: 4 0 Finland: 16 0 Denmark: 18 0 Norway: 17 0 Netherlands: 6 0 Luxembourg: 3 0 Belgium: 3 0 Australia: 2 0 New Zealand: 2 0
2 0 0 0 0 0 0 0 1 0 0 0 0 1 1 0 0 1 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
3 1 1 1 0 1 1 1 0 1 1 1 0 1 1 0 0 1 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
4 1 0 1 0 1 0 0 1 0 1 1 0 1 0 0 0 1 4 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 0 0
5 0 0 0 0 1 0 0 1 0 1 0 0 1 1 1 1 1 5 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0
6 1 0 1 1 1 1 0 0 1 1 0 0 0 0 1 0 1 6 0 0 0 1 0 1 0 1 1 0 0 0 1 0 0 0 0
7 0 0 0 0 0 0 0 0 1 0 0 1 1 0 1 0 1 7 0 0 1 0 1 1 0 0 0 0 1 0 1 1 1 1 1
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand SW Data NO. No. 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Item OC scan size default setting Switch selection and contents of functions Bit No. LETTER LEGAL A4 1 0 0 0 2 0 0 0 3 0 1 1 4 1 0 1 Initial value A 0 0 0 B 0 0 0 C 0 0 1 D 0 0 1 E 0 0 1 F 0 0 1 Remark G 0 Refer to User program 0 OC SIZE 1 PRIORITY. When a value outside 1 the set range is set, the initial value is set. 0 0 0 1 0 0 0 When a value outside 0 the set range is set, 0 the initial value is set. 0 0 1 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0
S W 82
1 1 1 1 1 1 Inhibited to use 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 1 0 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 1 0 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 1 0 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 1 1 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0
Inhibited to use Speaker sound volume setting pattern number Binary input Bit No. Set range
S W 83
3 4 5 6 7 8 Pattern No. 1 to 35
Inhibited to use
S W 84
Inhibited to use
S W 85
Inhibited to use
S W 86
Inhibited to use
S W 87
Inhibited to use
S W 88
SW Data Item NO. No. 1 Inhibited to use 2 3 S 4 W 5 89 6 7 8 1 Inhibited to use 2 3 S 4 W 5 90 6 7 8 1 Symbol speed 3429 send enable in V.34 send 2 Symbol speed 3200 high carrier send enable in V.34 send 3 Symbol speed 3200 low carrier send enable in V.34 send 4 Symbol speed 3000 high carrier S send enable in V.34 send W 5 Symbol speed 3000 low carrier 91 send enable in V.34 send 6 Symbol speed 3429 enable in V.34 communicate 7 Symbol speed 2800 enable in V.34 communicate 8 Symbol speed 2743 enable in V.34 communicate 1 Inhibited to use 2 3 S 4 W 5 92 6 7 8 1 Inhibited to use 2 3 S 4 W 5 93 6 7 8 1 Inhibited to use 2 3 S 4 W 5 94 6 7 8
Initial value 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Remark
1 1 1 1 1 1 1 1 0 1 0 1 1 0 0 0 0 1 0 1 1 0 0 0 0 1 0 1 1 0 0 0
Initial value 0 1 1 1 0 0 0 0 1 1 0 1 1 0 0 0 0 1 1 1 1 1 1 1 0 1 0 0 0 0 0 0 0 1 0 1 1 0 0 0 1 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1
Remark
Inhibited to use
Inhibited to use
Inhibited to use
Inhibited to use
Inhibited to use
Print effective image area sub scan Binary input lead edge void (Back surface) Bit No. Set range Print effective image area sub scan Binary input rear edge void (Back surface) Bit No. Set range
1 2 3 4 0 to 240 lines 16 lines interval (600dpi) 5 6 7 8 0 to 240 lines 16 lines interval (600dpi)
32 lines
48 lines
Item Scan effective image area main scan left edge image loss (OC)
Switch selection and contents of functions Binary input Bit No. Set range Binary input Bit No. Set range
Initial value 0 1 0 0 0 1 0 0 0 1 1 0 1 0 0 1 0 1 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Remark
1 2 3 4 0 to 360 dots 24 dots interval 5 6 7 8 0 to 360 dots 24 dots interval 1 2 3 4 0 to 240 line 16 lines interval 5 6 7 8 0 to 240 line 16 lines interval 1 2 3 4 0 to 360 dots in the interval of 24 dots 5 6 7 8 0 to 360 dots in the interval of 24 dots 0: +
96 dots
Scan effective image area main scan right edge image loss (OC)
96 dots
Scan effective image area sub scan Binary input lead edge image loss (OC) Bit No. Set range Scan effective image area sub scan Binary input rear edge image loss (OC) Bit No. Set range Scan effective image area main scan left edge image loss (RSPF back surface) Scan effective image area main scan right edge image loss (RSPF back surface) Binary input Bit No. Set range Binary input Bit No. Set range
96 lines
144 lines
96 dots
96 dots
S W 105
Scan magnification ratio adjustment 1: (OC main scan) flag Scan magnification ratio adjustment Binary input (OC main scan) Bit No. Set range
0%
S W 106
Scan magnification ratio adjustment 1: (OC sub scan) flag Scan magnification ratio adjustment Binary input (OC sub scan) Bit No. Set range
0: +
0%
S W 107
2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Scan magnification ratio adjustment 1: (RSPF back surface main scan) flag Scan magnification ratio adjustment Binary input (RSPF back surface main scan) Bit No. Set range
0: + +
0%
S W 108
Scan magnification ratio adjustment 1: (RSPF back surface sub scan) flag Scan magnification ratio adjustment Binary input (RSPF back surface sub scan) Bit No. Set range
0: +
0%
SW Data Item NO. No. 1 Print magnification ratio adjustment (Main scan back surface) flag 2 Print magnification ratio adjustment 3 (Main scan back surface) S 4 W 109 5 6 7 8 1 Print magnification ratio adjustment (Sub scan back surface) flag 2 Print magnification ratio adjustment 3 (Sub scan back surface) S W 110 4 5 6 7 8
Switch selection and contents of functions 1: Binary input Bit No. Set range 0: +
Initial value + 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Remark
0%
0: +
0%
SW5 No.1, No2 Inhibited to use SW5 No.3, No.4 G3 send data accumulation wait time
Used to set wait time for accumulation of image data before sending image data directly. Default: 0 0 (6sec)
SW1 No.6No.8 Inhibited to use SW2 No.1No.4 Inhibited to use SW2 No.5No.8 Remote selection number setup
Used to set the number in binary input for remote switch receive from external telephone. However, "" in the remote switch number (X) is fixed. Default: 5
SW6 No.7 Countermeasure for echo in reception (CED tone send interval)
Used to set the interval from CED send to FSK signal send of DIS. Default: 1 (500ms)
SW6 No.8 Countermeasure for echo in transmission (After reception of DIS, hold time up to signal send is set.)
Used to set the interval from DIS receive to DSC signal send. Default: 0 (500ms)
SW7 No.1 Dial tone ON/OFF detection time lower limit (Intermittent detection)
Used to set the minimum required time for detection of dial tone when the dial tone detection is set to "YES" and the kind of the dial tone detection is set to "Continuous." Default: 0 (100ms)
SW9 No.2 Inhibited to use SW9 No.3No.8 Ringing volume pattern number
Used to set ringing volume pattern. Default: 7 (North America) / 1 (Other than North America)
SW7 No.5 Dial tone ON/OFF detection time upper limit (Intermittent detection)
Used to set the upper limit time for detection of dial tone when the dial tone detection is set to "YES" and the kind of the dial tone detection is set to "Intermittent." If a dial tone is detected for more than this upper limit time, it is not considered as a dial tone. Default: 0 (700ms)
SW7 No.7, No.8 Destination display time when onetouch key is pressed
Used to set the time from displaying the destination to the next operation in one-touch dial or reduction dial. Default: 0 0 (2sec)
SW10 No.7, No.8 Inhibited to use SW11 No.1No.8 Inhibited to use SW12 No.1No.4 Call time setup in automatic transmission (T0 timer setup)
Used to set call time in automatic send. Setting is made by binary input of N into "(5sec x N) + 30sec" in the increment of 5sec. Default: 45sec
SW12 No.8 Inhibited to use SW13 No.1, No.2 Inhibited to use SW13 No.3, No.4 Ringing volume
Used to set the ringing volume when call-in. Default: 1 0 (Medium)
SW18 No.1No.8 Inhibited to use SW19 No.1No.5 Inhibited to use SW19 No.6 Recording table automatic print
Used to set whether communication report is automatically outputted or not when the number of send/receive items which have not outputted yet on communication report reaches 50. When set to 1, they are automatically outputted. When set to 0, they are not outputted even the number of items reaches 50. Default: 0 (No)
SW13 No.7, No.8 Inhibited to use SW14 No.1No.8 Inhibited to use SW15 No.1 Busy tone detection time (Lower limit)
Used to set the lower limit of busy tone detection time (ON time). Default: 0 (250ms)
SW19 No.7, No.8 Inhibited to use SW20 No.1, No.2 Line sound monitor range
Used to set line sound monitor range when line sound monitor function is used. Default: 0 0 (OFF)
SW20 No.6No.8 Inhibited to use SW21 No.1No.8 Interval between completion of communication and the next call
Used to set the interval between completion of communication and the next call. Setting is made in binary input. Default: 1sec (North America) / 6sec (Other than North America)
SW24 No.1, No.2 Inhibited to use SW24 No.3, No4 Specified number reception (ANTI JUNK FAX)
Used to set whether the FAX receive rejection function is made valid or not for registered FAX numbers. Default: 0 0 (Not set.)
SW24 No.5 Inhibited to use SW24 No.6 Document output setup in reception
Used to set the document output procedure; whether all the received documents are collectively outputted after completion of reception or every page is outputted when it is received. Default: 0 (Output after reception of every page) (North America) / 1 (Collective output after completion of reception) (Other than North America)
SW30 No.2No.4 Inhibited to use SW30 No.5 Default data, sender print
Used to set whether sender information (registered in the sender registration), sending date, and time are printed on the upper edge of send document or not. Default: 1 (ON)
SW30 No.6 Inhibited to use SW30 No.7 Date/sender print position setup
Used to set whether date/sender information is printed inside the document area or outside the document area. Default: 0 (Outside of document)
SW30 No.8 Inhibited to use SW31 No.1, No.2 Report output (in transmission)
Used to set whether communication report is outputted or not after completion of sending (excluding sequential broadcast and sequential send request). Default: 1 0 (Only when transmission is failed.)
SW31 No.3, No.4 Report output (In broadcast and sequential send request)
Used to set whether communication report is outputted or not after completion of sending (sequential broadcast and sequential send request). Default: 0 1 (All print)
SW26 No.2 Inhibited to use SW26 No.3, No.4 Speaker volume setup
Used to set speaker volume. The following sounds are the targets of this setting. Alarm sound Send end sound Receive end sound Scan end sound Default: 0 1 (Small)
SW31 No.7, No.8 Contents of send document are printed in memory send
Used to set whether part of send document is printed on the communication report or not in memory send. Default: 1 0 (Only the address to which transmission is failed)
SW26 No.5No.8 Inhibited to use SW27 No.1No.6 Inhibited to use SW27 No.7, No.8 Recording paper tray selection
Used to select the recording paper tray used by FAX. Valid only when two cassettes are installed. Default: 0 0 (AUTO)
SW32 No.7, No.8 Inhibited to use SW33 No.1 Page number print setup
Used to set whether the page number is added to the sender information print or not. Default: 1 (Yes)
SW28 No.1No.8 Inhibited to use SW29 No.1No.4 Number of auto switch calls of manual reception auto reception
Used to set the number of calls to switch to auto receive in manual receive mode. When set to 0, switch to auto receive is not made. Default: 0 time
SW38 No.8 Inhibited to use SW39 No.1No.3 Inhibited to use SW39 No.4No.8 DTMF signal send time
Used to set DTMF signal send time. Setting is made in binary input by the increment of 10ms. Default: 110ms (Other than Europe) / 80ms (Europe)
SW34 No.1, No.2 Flash send wait time (North America, U.K., Netherlands, Luxembourg, Belgium, France, Australia, New Zealand: Inhibited to use)
Used to set the time from off-hook to Flash send. Default: 1 0 (1sec)
SW34 No.3, No.4 Inhibited to use SW34 No.5No.8 Signal send level Max.
Used to set the max. signal send level. Default: 8dBm
SW35 No.2 Inhibited to use SW35 No.3, No.4 CI delete max. OFF time
Used to set the max. wait time between detection of CI signal pulse (number of times) and detection of the next CI signal pulse. If CIK signal pulse is not detected within this time, the number of calls up to that time is cleared. Default: 0 0 (5sec) (Other than Europe) / 0 1 (10sec) (Europe)
SW42 No.4No.7 Inhibited to use SW42 No.8 V.34 mode function in manual communication
Used to set whether V.34 mode is enabled or not in manual communication. When, however, SW43-1 is set to "0: OFF," V.34 mode is disabled even tough this switch is set to "1: ON." Default: 1 (ON)
SW43 No.2, No.3 Inhibited to use SW43 No.4No.6 Symbol speed mask in V.34 receive
Used to set symbol speed mask in V.34 receive. Default: 1 0 1 (3429)
SW43 No.7, No.8 Inhibited to use SW44 No.1No.4 V.34 primary channel send speed
Used to set send start speed in V.34 send. Setting is made in binary input of N in "2400 (bps) x N" in the range of 2400bps 33600bps. N is set in the range of 0 15. When set to 0, 2400bps; when set to 15, 33600bps. When set to 2400bps, all of SW91 No. 1 8 must be set as "Disable". Default: 33600bps
SW38 No.4 Inhibited to use SW38 No.5, No.6 Flash send time (North America, U.K., Netherlands, Luxembourg, Belgium, France, Australia, New Zealand: Inhibited to use)
Used to set the Flash send time. Default: 0 0 (90ms)
SW46 No.6No.8 PBX setting (North America, U.K., Netherlands, Luxembourg, Belgium, Australia, New Zealand: Inhibited to use)
Used to set Connect/Not Connect to PBX and to set the external line connection method when connected to PBX. Default: 0 0 0 (Setting OFF)
SW45 No.2, No.3 Sequence of year/month/day in LCD, report, and sender record
Used to set the sequence of year/month/day in LCD, report, and sender record. Default: 0 1 (Month/Day/Year) (North America) / 1 0 (Day/Month/Year) (Other than North America)
SW47 No.3No.8 Inhibited to use SW48 No.1, No.2 Tone/Pulse default setup
Used to set the dial type. Default: 1 0 (TONE)
SW45 No.5No.8 Scan effective image area main scan right edge image loss (RSPF)
Used to set image loss of scan effective area. Image loss on the right edge in RSPF main scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 24 dots. Default: 96 dots
SW48 No.4 Inhibited to use SW48 No.5No.8 Scan effective image area main scan left edge image loss (RSPF)
Used to set image loss of scan effective area. Image loss on the left edge in RSPF main scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 24 dots. Default: 96 dots
SW49 No.1, No.2 Inhibited to use SW49 No.3No.8 Speaker sound volume pattern number in DTMF send
Used to set sound volume pattern in DTMF send. Default: 1
SW52 No.3 Inhibited to use SW52 No.4 Super G3 disabled in the last call-out of recall in case of an error
Used to set whether Super G3 is disabled or not in the last call-out of recall in case of a send error. When, however, the number of recall in case of a send error is 0, this function does not operate. Default: 0 (Super G3 disabled)
SW55 No.8 Inhibited to use SW56 No.1No.3 CI signal ON detection enable time
Used to set the min. ON time for judgment of 1 pulse (1 call) of CI (call-in signal). If ON time continues more than the set value, it is judged as 1 pulse. Setting is made in binary input in the increment of 10ms. Default: 155ms (North America, Europe) / 195ms (Australia, New Zealand)
SW56 No.4 Inhibited to use SW56 No.5, No.6 DT/BT detection frequency range
Used to set DT/BT detection frequency range. Default: 1 1 (245Hz650Hz) (Other than New Zealand) / 1 0 (360Hz440Hz) (New Zealand)
SW56 No.7, No.8 Inhibited to use SW57 No.1 Inhibited to use SW57 No.2 Sharp machine mode
Used to set whether communication is made in Sharp machine mode or not. Default: 1 (ON)
SW52 No.6, No.7 Inhibited to use SW52 No.8 V.34 control channel communication speed
Used to set control channel communication speed in V.34 mode. If the remote machine does not make 2400bps enable, the speed is always 1200bps. Default: 0 (1200bps)
SW53 No.5No.8 DTMF send level (difference between high and low level)
Used to set DTMF signal send level in low group by the difference from that in high group. Setting is made in binary input in the increment of 0.5dBm. Default: +2.0dBm (Other than New Zealand) / +1.5dBm (New Zealand)
SW54 No.1No.4 Scan effective image area sub scan lead edge image loss (RSPF)
Used to set image loss in scan image area. Image loss on the lead edge in RSPF sub scan direction can be adjusted. When the set value is increased, image loss on the lead edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 96 lines
SW59 No.1, No.2 Inhibited to use SW59 No.3, No.4 Reception SED ON level
Used to set reception SED ON level. Default: 1 1 (48dB)
SW54 No.5No.8 Scan effective image area sub scan rear edge image loss (RSPF)
Used to set image loss in scan image area. Image loss on the rear edge in RSPF sub scan direction can be adjusted. When the set value is increased, image loss on the rear edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 144 lines
SW60 No.1No.4 Scan effective image area sub scan lead edge image loss (RSPF back surface)
Used to set image loss in scan image area. Image loss on the lead edge in RSPF bask surface sub scan direction can be adjusted. When the set value is increased, image loss on the lead edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 96 lines
SW60 No.5No.8 Scan effective image area sub scan rear edge image loss (RSPF back surface)
Used to set image loss in scan image area. Image loss on the rear edge in RSPF bask surface sub scan direction can be adjusted. When the set value is increased, image loss on the rear edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 144 lines
SW61 No.1No.8 Inhibited to use SW62 No.1No.3 Inhibited to use SW62 No.4, No.5 V.8 mode ANSam signal send time
Used to set ANSam/CED signal send time. Default: 0 1 (4sec)
SW62 No.6No.8 Inhibited to use SW63 No.1No.8 Inhibited to use SW64 No.1No.8 Inhibited to use SW65 No.1No.8 Inhibited to use SW66 No.1No.8 Inhibited to use SW67 No.1No.4 Make time (10PPS) setup
Used to set make time in dialing in 10PPS. Setting is made in binary input in the increment of 1ms. Default: 40ms (North America) / 33ms (U.K., Netherlands, Luxembourg, Belgium, France) / 41ms (Germany, Sweden, Spain, Italy, Switzerland, Finland, Denmark, Norway) / 31ms (Australia) / 34ms (New Zealand)
SW72 No.6 Inhibited to use SW72 No.7, No.8 CNG send start
Used to set CNG send time. Default: 0 0 (0.5sec)
SW73 No.1No.8 Inhibited to use SW74 No.1No.4 Print effective image area sub scan lead edge void
Used to set print image area void. The void amount on the lead edge in the sub scan direction can be adjusted. When the set value is increased, the void amount on the lead edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 32 lines
SW67 No.5No.8 Inhibited to use SW68 No.1, No.2 Line open delay time in dial test
Used to set time interval between end of dialing and opening the line. Valid only in dial test of simulation. Default: 0 0 (2sec)
SW74 No.5No.8 Inhibited to use SW75 No.1 Manual calibration setting when sending
Setting to execute the manual calibration or not when sending. In case of an abnormal current waveform, the auto calibration fails and the DTFM signal is deformed. This setting provides the countermeasure against that problem. Default: 0 (OFF)
SW69 No.1No.8 Inhibited to use SW70 No.1No.3 Inhibited to use SW70 No.4 Reception waiting time between frames
Used to set reception wait time between frames. Default: 0 (3.4sec)
SW75 No.3, No.4 Communication end sound (Buzzer sound length) setting
Used to set the length of communication end buzzer sound in communication. Default: 0 0 (3sec)
SW82 No.5No.8 Inhibited to use SW83 No.1, No.2 Inhibited to use SW83 No.3No.8 Speaker sound volume setting pattern number
Used to set sound volume pattern of communication end and scan end. Default: 1
SW84 No.1No.8 Inhibited to use SW85 No.1No.8 Inhibited to use SW86 No.1No.8 Inhibited to use SW87 No.1No.8 Inhibited to use SW88 No.1No.8 Inhibited to use SW89 No.1No.8 Inhibited to use SW90 No.1No.8 Inhibited to use SW91 No.1 Symbol speed 3429 send enable in V.34 send
Used to set whether symbol speed of 3429Hz is allowed or not in V.34 send. Default: 1 (Enable)
SW91 No.2 Symbol speed 3200 high carrier send enable in V.34 send
Used to set whether use of high carrier is allowed or not when symbol speed of 3200Hz is selected in V.34 send. When high/low carriers are "disable", 3200Hz cannot be selected. Default: 1 (Enable)
SW91 No.3 Symbol speed 3200 low carrier send enable in V.34 send
Used to set whether use of low carrier is allowed or not when symbol speed of 3200Hz is selected in V.34 send. When high/low carriers are "disable", 3200Hz cannot be selected. Default: 1 (Enable)
SW91 No.4 Symbol speed 3000 high carrier send enable in V.34 send
Used to set whether use of high carrier is allowed or not when symbol speed of 3000Hz is selected in V.34 send. When high/low carriers are "disable", 3200Hz cannot be selected. Default: 1 (Enable)
SW91 No.5 Symbol speed 3000 low carrier send enable in V.34 send
Used to set whether use of low carrier is allowed or not when symbol speed of 3000Hz is selected in V.34 send. When high/low carriers are "disable", 3200Hz cannot be selected. Default: 1 (Enable)
SW104 No.1No.4 Scan effective image area main scan left edge image loss (RSPF back surface)
Used to set image loss in scan image area. Image loss in RSPF back surface main scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 24 dots. Default: 96 dots
SW92 No.1No.8 Inhibited to use SW93 No.1No.8 Inhibited to use SW94 No.1No.8 Inhibited to use SW95 No.1No.8 Inhibited to use SW96 No.1No.8 Inhibited to use SW97 No.1No.8 Inhibited to use SW98 No.1No.8 Inhibited to use SW99 No.1No.8 Inhibited to use SW100 No.1No.8 Inhibited to use SW101 No.1No.4 Print effective image area sub scan lead edge void (Back surface)
Used to set void amount in print image area. Void amount on the lead edge in sub scan direction can be adjusted. When the set value is increased, the margin on the lead edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 32 lines
SW104 No.5No.8 Scan effective image area main scan right edge image loss (RSPF back surface)
Used to set image loss in scan image area. Image loss on the right edge in RSPF back surface main scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 24 dots. Default: 96 dots
SW105 No.1 Scan magnification ratio adjustment (OC main scan) flag
Used to set the main scan magnification ratio in OC scan. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)
SW101 No.5No.8 Print effective image area sub scan rear edge void (Back surface)
Void amount on the rear edge in sub scan direction can be adjusted. When the set value is increased, the margin on the read edge is increased. Setting is made in binary input in the increment of 16 lines. Default: 48 lines
SW106 No.1 Scan magnification ratio adjustment (OC sub scan) flag
Used to set the sub scan magnification ratio in OC scan. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)
SW102 No.1No.4 Scan effective image area main scan left edge image loss (OC)
Used to set image loss in scan image area. Image loss on the left edge in OC main scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 24 dots. Default: 96 dots
SW102 No.5No.8 Scan effective image area main scan right edge image loss (OC)
Used to set image loss in scan image area. Image loss on the right edge in OC main scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 24 dots. Default: 96 dots
SW107 No.1 Scan magnification ratio adjustment (RSPF back surface main scan) flag
Used to set the main scan magnification ratio in RSPF back surface scan. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)
SW107 No.2No.8 Scan magnification ratio adjustment (RSPF back surface main scan)
Used to set the main scan magnification ratio in RSPF back surface scan. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%
SW103 No.1No.4 Scan effective image area sub scan lead edge image loss (OC)
Used to set image loss in scan image area. Image loss on the lead edge in OC sub scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 16 lines. Default: 96 lines
SW108 No.1 Scan magnification ratio adjustment (RSPF back surface sub scan) flag
Used to set the sub scan magnification ratio in RSPF back surface scan. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)
SW103 No.5No.8 Scan effective image area sub scan rear edge image loss (OC)
Used to set image loss in scan image area. Image loss on the rear edge in OC sub scan direction can be adjusted. When the set value is increased, image loss is increased. Setting is made in binary input in the increment of 16 lines. Default: 144 lines
SW108 No.2No.8 Scan magnification ratio adjustment (RSPF back surface sub scan)
Used to set the sub scan magnification ratio in RSPF back surface scan. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%
SW109 No.1 Print magnification ratio adjustment (Main scan back surface) flag
Used to set the main scan magnification ratio in back surface print. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)
SW109 No.2No.8 Print magnification ratio adjustment (Main scan back surface)
Used to set the main scan magnification ratio in back surface print. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%
SW110 No.1 Print magnification ratio adjustment (Sub scan back surface) flag
Used to set the sub scan magnification ratio in back surface print. Bit 1 indicates plus or minus of the magnification ratio. Default: 0 (+)
SW110 No.2No.8 Print magnification ratio adjustment (Sub scan back surface)
Used to set the sub scan magnification ratio in back surface print. By binary input, setting can be made in the range of 0 12.7% in 0.1% increments. Default: 0%
35 36 37 38 39
Power OFF (Recording paper empty) (Recording paper jam) Reception memory over (Discrepancy in the number of sheets) (Interface not accepted) Transmission length over
40 41
42
Reception length over Communication (OK) Document error (Image quality error) No response from the other party (Communication error) OK No send request function on the other party
43 44 45 46
The length of transmission data of one page exceeds the range during transmission. The length of reception data of one page exceeds the range during reception. Communication enable before transmission A document jam during direct transmission
The FAX signal from the other party cannot detect within T1 time.
47 48 49
50
52
Communication normal end The other party has no send request function when receiving a send request. The other party has no data to send. Send request not DCN is received for DTC accepted when sending a send request. There is no data to send when sending a send request. Send request Discrepancy in the enable enable number number when sending a discrepancy send request. Discrepancy in the system number when sending a send request. No confidential The other party has no function on the confidential function when other party sending a confidential message. (Including the other companys machines)
Error code Communication (Communication report result result) column 53 Confidential function not accepted 54 Confidential box No. NG
55
56
57
58
DCN is received for NSS when receiving a confidential message. A confidential box number which is not registered is directed when receiving a confidential message. No interface The other party has no function on the interface function when other party sending an interface command. Interface not DCN is received for NSS accepted when sending an interface command. A receiving station number which is not registered is directed when receiving an interface command. Interface ID Discrepancy in the interface discrepancy ID when receiving an interface command. Reception Transmission is made from a inhibition number reception inhibition number.
Abnormal signal NSF, DIS CFR FTT MCF PIP, PIN RTN, RTP No signal PPR RNR CTR ERR V.8 Phase-1 V.8 Phase-2 V.8 Phase-3
1/6
4
4
Q2 2SD1733 DAA3.3V C15 B0.22uF/16V(1608) C14 B1uF/16V(2125) IC 1 TP25 TP16 TP13 R3 10(2125) 150pF/AC250V(7.5mm) Si3021-FS TP21 TP23 C10 B0.1uF/16V(1608) TP317 DAAGND C9 B1000pF 10(2125) TP12 R1009 2.2K(2125) TP26 TP1 Si3015-FS TP15 TP17 TP4 TP3 C5 R2 TP24 C1005 B0.1uF/50V(2125) C4 10pF/50V(1608) IC 3 MCLOCK ASPCLK ABITCLK ARXD ATXD AFERST_L R11 0R(1608) DAA3.3V R1008 150(1608)
Q1 2SC4548(E) C E
Q1000 2SA1759 E C
R 12 100kF(1608)
16 15 14 13 12 11 10 9 FILT2 FILT RX REXT REXT2 REF VREG2 VREG QE2 DCT IGND C1B RNG1 RNG2 QB QE
1 2 3 4 5 6 7 8
TP30 16 15 14 13 12 11 10 9
OFHK MCLK RGDT/FSD FSYNC M0 SCLK VA VD GND SDO C1A SDI M1 FC/RGDT AOUT RESET
1 2 3 4 5 6 7 8
TP8 R8 10K
R1001 78.7F(1608)
402F(1608)
B1800pF/50V(1608)
9 .31kF(1608)
Z D1001 R D43FM
5.36kF 1/4W(3226)
5.36kF 1/4W(3226)
5.36kF 1/4W(3226)
1.78kF 2W(N.M.)
B0.1uF/16V(1608)
RL Z5.6
C1003
D2 D AN217
C1004 B0.01uF/50V(1608)
B0.1uF/16V(1608)
AK
D1 D AN217 A C13 B0.022uF/250V(2125) TPGND C12 (3216)N.M.
R1002
TP31 R 42 R1015
215F(1608)
AK
C1000
R1010
R1016
R4
C1002 B0.68uF/16V(2125)
Z D1000
3
C11 150pF/AC250V(7.5mm) DAAGND
Q1001 2SC4548(E)
3
DAAGND G ND
MJ1 TP27
L3
FB1 BLM31A601S
L1 TWKA-221KNP
R1011 56k(2125)
C1008 B560pF/250V(2125)
L1 L2
D6
SBT-0260
C6 2200pF(KH)
SBT-0260
DSS-401M
R 14 10M(1608)
1 2 3 4 5 6 2 1
SA2
L4
+24V
SA3 DSS-401M
3
DSS401M(N,M.) S1ZB60 R1012 56k(2125) TP33 C1009 B560pF/250V(2125)
SA1
B0.01uF/250V(2125 N.M.) C 16
DSS-401M
C7 2200pF(KH)
FB2 BLM31A601S
L2 TWKA-221KNP
R 15 10M(1608)
R Y1 A OUAZ-SH-124DZ 1
2
C34 R41 10k 1W D7 1SS355 Z D3 MTZJ30B C ID_L
Z D4 HZS2A1
PC2A TLP620
2
3
2
R Y1 B
4
OUAZ-SH-124DZ
Q3 DTC123JKA B
H1 0.47uF/250V DAAGND
G ND
G ND
MJ2
L6
1 2 3 4 5 6
SBT-0260
MJ-62J-RD315/MJ-66J-RD315
Z D5 HZS2A1
C63 B1000pF
L5
1
G ND
SBT-0260
2/6
5 6k 5 6k 5 6k 5 6k
D
R1 64 R1 7 0 R1 69 R1 66 V re f V re f 1M R173 10K(N.M.) R179 100k R180 200K R167 1K C145 100pF
C138 0.1 u F
SPOUT
TP310
C135 0.1 u F R168 3.3K R1 6 2 TP311 IC11 C134 0.1 u F IC10 C132 0.1 u F TP292 TP297 TP341 R158 3.3K TP293 TP296 R176 3.3k TP338 TP337
BZ
TP316 R172
20k
TP315
TP312
3 X 4 2 3 1 7 8
C N3
5
IC12 NJM2113M
TP331
R181
0R
1 2
B2B-PH-K-S
+5V
+5V
C136 4700pF
R171 1. 6 k
C139 2200pF
16 VDD
13 14 15 12 1 5 2 4 X0 X1 X2 X3 X4 X5 X6 X7 16
C144 A 4 .7u F/5 0V
7 8 VEE VSS
6 11 10 9 INH A B C 7 8
AG BU 4 0 5 1BCF
AG
+5V
R165 4 .7k
AG
VOLCNT_A
TP308
4 . 7k
R1 54
R1 5 2
4 . 7k R1 5 1
VOL_A
TP306
VOL_B
TP301
VOL_C
TP300
4 . 7k
VOLCNT_B
TP307
3/6
D[ 7 :0]
A [21:0] A0 TP197
D
IC 9 IC 8
29 28 27 26 25 23 22 21
D7 D6 D5 D4 D3 D2 D1 D0
NC
BAT
DQ15 DQ14 DQ13 DQ12 DQ11 DQ10 DQ9 DQ8 DQ7 DQ6 DQ5 DQ4 DQ3 DQ2 DQ1 DQ0 RY/BY BYTE VPP VCC 13 37 15 47
45 43 41 39 36 34 32 30 44 42 40 38 35 33 31 29
VCC
C73 0.1 u F TP276 + C74 A 47u F/25V F_WP CS_FL RESETL
A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1
TP175 TP145 TP146 TP129 TP130 TP151 TP153 TP155 TP156 TP176 TP152 TP154 TP157 TP177 TP178 TP179 TP180 TP193 TP194 TP195
9 16 17 48 1 2 3 4 5 6 7 8 18 19 20 21 22 23 24 25 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0
C
OEL WEL TP148 TP149
G ND
+3.3V
BAT
R73 10k
IC 5 C55 C54
7 6 5
TP85
8
12pF 12pF
G ND
TP66 G ND
TR3 KTA1504
CS_S1L
R60 1k
G ND
+3.3V
BAT
3 2 4
C59 0.1 u F R79 10k C52 12pF(N.M.) C51 1 8 pF(N.M.)
Z D2 UDZ2.0B
TR4 KTA1504
4 3
1 2
X3 DT-3 8 32.768KHz
TP67
TP70
R35 20k
B
VCC
PST3426
R36 1k
C31 0.1 u F
D3 1SS355
B
G ND G ND JP1 0R
TP68 G ND
TP69
R6 1k
TR2 KTC3875
R61 1k
G ND
BT1 HL 5 0-A G ND G ND
TP28 C_BT
TR1 DTC363EKA C B
G ND
+3.3V
4/6
D
+3.3V +3.3V
G ND
G ND
+3.3V
R53
4 .7k
+3.3V
MDM_IRQ C LKIN R47 33 +3.3V G ND +3.3V R50 33 X1 S G -7 10ECK 2 4.576M S-L3 TP55 3 OUT OE 1 FB11 ACH32 N.M.
TP65
R54
0R
TP81
C47 0.1 u F C49 0.1 u F C26 0.1 u F C40 0.1 u F C43 0.1 u F C45 0.1 u F C19 A33 u F/10V C22 0.1 u F C21 0.1 u F
C24 0.1 u F C25 1uF C46 0.1 u F C44 0.1 u F C42 1uF C23 1uF C27 0.1 u F C29 0.1 u F C48 0.1 u F C41 1uF
55 54
92 78 68 44 30 15 3
34
97 86 62 42 21 9
53 52
G ND
2 GND
C65 C 47 0 u F C66 0.1 u F
IC 4
VDD
1 T3IRQ
TP61 R48 47K TP60 TP56 TP48 TP47 R18 MCLOCK C LKIN C N1 C39 10pF R46 33(N.M.) 75 TP36
AVDD
VDDREG VDDREG
+3.3V
R28 R29
47K 47K
TP49 TP50
75 74 73 71 72 NDPCS NDPRD NDPWR NUB NLB NRESET CXIN CXOUT CLKOUT CNT LON 39 38 43 37 51 41
REGOUT REGOUT
26 27 36 33 31 29 28
G ND
G ND
M_RESETL
C36 100pF
G ND
+3.3V
A[21:0] G ND
A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0
100 98 96 95 94 93 91 90 88 87 85 84 45 46 48 49 50 57 58 1 2 3 4 5 6
A2-6 PA-2.54DSA(NM)
DPA11 DPA10 DPA09 DPA08 DPA07 DPA06 DPA05 DPA04 DPA03 DPA02 DPA01 DPA00 EYECLK EYEDAT
R19 47K
R20 47K
BR1
AVSS
35
99 89 80 70 64 56 47 40 32 23 17 11 5
VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS
D[ 7 :0]
59 60 63 61
B
G ND TP45 TP53 TP58 TP59 TP52 TP51 +3.3V R55 R58 47K 47K
5 6 7 8 BBITCLK BSPCLK BTXD BRXD GPIO0 GPIO1 GPIO2 GPIO3 GPIO4 GPIO5 76 77 79 81 82 83
R32 R33 R56 47K 47K 47K
+3.3V
R23 47K
B
G ND
D7 4 5 D6 3 6 D5 2 7 D4 1 8 BR 7 D3 4 D2 MNR0 4 33 3 D1 2 D0 1 R91 47K MNR0 4 R92 47K R93 47K R95 47K R96 47K R97 47K R98 47K R52 47K
33
TP78 TP77 TP79 TP62 TP92 TP93 TP94 TP95 TP96 TP98 TP97 TP99 TP100 TP101 TP102 TP80
25 24 22 20 19 18 16 14 13 12 10 8 7 6 4 2 DPD15 DPD14 DPD13 DPD12 DPD11 DPD10 DPD09 DPD08 DPD07 DPD06 DPD05 DPD04 DPD03 DPD02 DPD01 DPD00 65 66 69 67
TP39 TP43 TP44 TP38 R25 R26 R31 R27 47k 47k 47k 47k
G ND
8
D [7:0] A[21:0] MCU_D[7:0] PB_A[7:0] PB_D[7:0]
5/6
D
PB_D0 PB_D1 PB_D2 PB_D3 PB_D4 PB_D5 PB_D6 PB_D7 FL17 IC 7 C80 0.1uF TP123 TP122 MCU_INT MCU_CEL MCU_OEL G ND FL11 C79 0.1uF G ND (N.M.) +3.3V (N.M.) +3.3V
BR17 MNR04 47 1 8 2 7 3 6 4 5
1 BR16 2 MNR04 47 3 4
8 7 6 5
+3.3V
BR24
1 2 3 4
8 7 6 5
MNR04 22K +3.3V R102 +3.3V FL18 (N.M.) PB_CS1L PB_AE0L 10K TP187 TP118 TP136 TP115 TP116
1 2 3 4
8 7 6 5
BR22
0R 8 7 6 5
MNR04 22K
BR23
1 2 3 4 1 2 3 4
MNR04 0R
8 7 6 5
(N.M.)
+3.3V
1 2 3 4
C81 0.1uF PB_WEL PB_OEL RESETL W AKE_UP TP206 TP204 TP205 TP230 TP22 HS2L CID_L HS1L F _ R YB Y R137 +3.3V C102 0.1uF R131 G ND R130 10K 10K FL19 (N.M.) R139 10K 10K G ND EXHKD_L
8 7 6 5
MNR04(N.M.)
C
1 2 3 4
D8 DA204U JP2 T2B-SQ TP260 TP229 TP228 TP259 uPD65 9 44GM-P07-JED-A RGDT-
MNR04(N.M.)
C
+3.3V R68 RTC_CE0H RTC_CLK RTC_DATA CS_S0L
BR6
4 3 2 1
5 6 7 8
TP111
10K(N.M.) CS_OP1L CS_OP2L R71 R66 R65 R63 0R A21 C58 18pF FL16 C77 0.1uF (N.M.) +3.3V C56 18pF C53 18pF 100 100 100 CS_ML OEL WEL
R62 R100
10K 10K
BR 9
4 3 2 1
G ND
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 VDD PB_DAT_05 PB_DAT_04 PB_DAT_03 PB_DAT_02 PB_DAT_01 PB_DAT_00 TESTMODE0 PB_ADDR_07 PB_ADDR_06 PB_ADDR_05 PB_ADDR_04 PB_ADDR_03 PB_ADDR_02 PB_ADDR_01 PB_ADDR_00 PB_CE2_N PB_CE1_N PB_AE0_N VDD GND PB_WR_N PB_OE_N RESET_N WAKE_UP FGPI_07 FGPI_06 FGPI_05 FGPI_04 FGPI_03 FGPI_02 FGPI_01 FGPI_00 FGPIO_07 FGPIO_06 FGPIO_05 FGPIO_04 TCK TRST VDD GND GND PB_DAT_06 PB_DAT_07 CPU_INT_N CPU_CS_N CPU_RD_N VDD GND CPU_DT_00 CPU_DT_01 CPU_DT_02 CPU_DT_03 GND CPU_DT_04 CPU_DT_05 CPU_DT_06 CPU_DT_07 VDD GND FAXWRIN_N UART_RTS UART_CTS UART_SOUT UART_SIN RTC_ION RTC_CE RTC_SCLK RTC_SDATA FAXCS_N_00 FAXCS_N_01 FAXCS_N_02 FAXCS_N_03 FAXCS_N_04 FAXCS_N_05 FAXOE_N FAXWR_N FAXADD_21 GND GND
160 159 158 157 156 155 154 153 152 151 150 149 148 147 146 145 144 143 142 141 140 139 138 137 136 135 134 133 132 131 130 129 128 127 126 125 124 123 122 121
5 6 7 8
BR10
MNR04 10K
G ND
BR11
4 3 2 1
5 6 7 8
BR12 MNR04 100 1 8 2 7 3 6 4 5 TP103 TP105 TP104 TP106 TP131 TP134 TP132
MNR04 10K C_BT L_BTR129 G ND M_RESETL S +3.3V FL22 (N.M.) R127 10K BZ
4 3 2 1
5 6 7 8
BR25
MNR04 10K
4 3 2 1
TP319 TP320 TP255 100 TP254
5 6 7 8
PB_D7 PB_D6 PB_D5 PB_D4 PB_D3 PB_D2 PB_D1 PB_D0 PB_A7 PB_A6 PB_A5 PB_A4 PB_A3 PB_A2 PB_A1 PB_A0 PB_CS1L PB_AE0L PB_WEL PB_OEL D7 D6 D5 D4 D3 D2 D1 D0 A21 A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 TP257 TP258 TP285 TP284 TP283 TP323 TP256 TP321 TP282
MNR04 10K
1 2 3 4
8 7 6 5
MNR04 100
(N.M.)
+3.3V +3.3V
BR2
R101 A20 100 A19 A18 A17 BR13 A16 MNR04 100 1 8 A15 2 7 A14 3 6 A13 4 5 A12 A11 A10 A9 BR15 A8 1 8 A7 2 7 A6 3 6 A5 4 5 A4
BR4
1 2 3 4
8 7 6 5
B
1 2 3 4 8 7 6 5
MNR04 100 G ND C104 A47uF/25V
1 2 3 4
8 7 6 5
MNR04(N.M.)
MNR04(N.M.)
M CU_D7 M CU_D6 M CU_D5 M CU_D4 M CU_D3 M CU_D2 M CU_D1 M CU_D0 M CU_INT MCU_CEL MCU_OEL
R77 R67
10K 10K
WEL OEL
MNR04 100 A3 A2 A1 BR28 A0 1 8 2 7 3 6 4 5 R115 R116 R120 100 100 MNR04 100 0R(N.M.)
D0 D1 D2 D3 D4 D5 R121
G ND
R122 10k(N.M.)
R133 R132
10K 10K
41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 GND GND TMS NC TDI TDO FGPIO_03 FGPIO_02 FGPIO_01 FGPIO_00 TELELIN BEEP_O_V1 BEEP_O_V2 FGPO_15 FGPO_14 FGPO_13 FGPO_12 GND FGPO_11 FGPO_10 FGPO_09 FGPO_08 GND VDD FGPO_07 FGPO_06 FGPO_05 FGPO_04 FGPO_03 FGPO_02 FGPO_01 FGPO_00 FAX_DATA_07 FAX_DATA_06 VDD GND XIN XOUT GND GND
VDD FAXADD_20 FAXADD_19 FAXADD_18 FAXADD_17 FAXADD_16 FAXADD_15 FAXADD_14 GND FAXADD_13 FAXADD_12 FAXADD_11 FAXADD_10 FAXADD_09 FAXADD_08 FAXADD_07 FAXADD_06 FAXADD_05 FAXADD_04 GND VDD FAXADD_03 FAXADD_02 FAXADD_01 FAXADD_00 FAX_DATA_00 FAX_DATA_01 FAX_DATA_02 FAX_DATA_03 FAX_DATA_04 FAX_DATA_05 TMD0_OUT TOUT TESTB TMD2 TMD1 TMD0 SYSCLK_IN CLKSEL VDD
120 119 118 117 116 115 114 113 112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
R134 R138
10k 10k
C ID_L EXHKD_L
R118 10k
R128 R143
10K 22K
G ND + IC 6 C LKIN R89 TP143 C70 0.1uF G ND G ND C69 270pF G ND 510 TP173 TP57 TP142 TP172 R88 0R TP249 R123 0R G ND C68 0.1uF P2782A-08SR C99 100pF TP273 R124 75 G ND C98 0.1uF
(N.M.)
+3.3V G ND G ND
1 2 3 4 Xin Xout S1 LF
G ND
8 7 6 5
6/6
8 7 6 5
#MDM_IRQ #RESET#PB_nOE #PB_nWE #PB_nAE0 #PB_nCS1
R183
D
33pF 33pF 33pF FB10 MNR0 4 33 + C162 0.1 u F G ND G ND G ND G ND G ND G ND FB14 ACH32 N.M. + FB13 ACH32 N.M. C87 + A 47u F/35V
33 5 6 7 8
4 3 2 1
BR20 MNR0 4 0R
B1000pF
100pF
A 47u F/25V C 85
C1 56
C1 47
C1 55
C1 54
C1 5 3
G ND
C1 58
PB_A[7 :0] 33 8 7 6 5 #PB_A0 #PB_A1 #PB_A2 #PB_A3 #PB_A4 #PB_A5 #PB_A6 #PB_A7
BR1 9 MNR0 4 0R 5 4 6 3 7 2 8 1 C N2
A 47u F/25V C1 6 0
D9 1SS3 55 (N.M.)
10pF/ 50V
C83 1000pF(N.M.)
C84 0.1 u F
5 6 7 8
33pF 33pF 33pF 33pF 33pF FB8 MNR0 4 33
4 3 2 1
FB9 MNR0 4 1 2 3 4
40
1 2 3 4
8 7 6 5
33pF
33pF
C1 5 2
C1 5 1
C1 5 0
33pF C1 57
BR1 8 MNR0 4 0R
C1 49
C1 48 C113
C11 7
C
B 4 0B-PNDZS-1
IN 5 V #MDM_IRQ #PB_nOE #PB_nAE0 #PB_A0 #PB_A2 #PB_A4 #PB_A6 #PB_D0 #PB_D2 #PB_D4 #PB_D6 #MCU_INT #MCU_nOE #MCU_D1 #MCU_D3 #MCU_D 5 #MCU_D 7
39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1
IN3.3V IN 2 4 V #RESET#PB_nWE #PB_nCS1 #PB_A1 #PB_A3 #PB_A5 #PB_A7 #PB_D1 #PB_D3 #PB_D5 #PB_D7 #MCU_ n CS #MCU_D0 #MCU_D2 #MCU_D 4 #MCU_D 6
40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2
G ND
G ND
PB_D[7 :0] TP289 TP264 TP266 TP263 TP265 TP262 TP233 TP232 33 8 7 6 5 #PB_D0 #PB_D1 #PB_D2 #PB_D3 #PB_D4 #PB_D5 #PB_D6 #PB_D7 +3.3V C28 0.1 u F TP35 R30 22 +3.3V C91 0.1 u F TP271 R112 22
FB4 MNR0 4 1 2 3 4
1 2 3 4
FB3 MNR0 4 33
8 7 6 5
33pF
33pF
33pF
33pF
33pF
33pF
33pF
33pF
C112
C111
C110
C11 6
C10 9
C10 8
C10 7
G ND
C11 5
G ND
G ND
G ND
G ND +3.3V +3.3V C159 0.1 u F TP342 +3.3V C2 0.1 u F TP6 R186 22 R7 22 +3.3V C146 0.1 u F TP332 R182 22 C88 0.1 u F TP170 R109 22
G ND
G ND
G ND
G ND
10pF/ 50V
10pF/ 50V
10pF/ 50V
C12 6
C12 5
C12 4
10pF/ 5 0V(N.M.)
10pF/ 5 0V(N.M.)
10pF/ 5 0V(N.M.)
10pF/ 5 0V(N.M.)
10pF/ 5 0V(N.M.)
10pF/ 5 0V(N.M.)
C11 9
C123
C12 8
C122
C11 8
C121
C12 7
10pF/ 5 0V(N.M.)
G ND
C120
10pF/ 5 0V(N.M.)
R147 R146
0R 0R
TP236 TP234
G ND
G ND
G ND
G ND G ND G ND G ND G ND
+3.3V
MCU_D[7 :0]
A
FB5 MNR0 4 100
5 6 7 8
G ND
G ND
G ND
G ND
G ND
1/6
R49
4
Q4 2SD1266A(N.M.) 4 3 Q5 2SD1733
4
+3.3V
Q2 2SC4548(E) C E
+3.3V C20 B0.22u/16V(1608) C1A 150p(KH) C1 TP4 R1 10 1/10W(2125) N.M.(5750) TP25 10 1/10W(2125) TP3 TP24 R11 C11 10pF/50V(1608) C21 B1uF/16V(2125) TP15 IC 1 TP13 TP11 R17 2.2K 1/10W(2125) C4 B0.1u/50V(2125)
R14 0R(1608)
R 16 100kF(1608)
R1005 150(1608)
TP36
Q3 2SA1759 E C
TP12
TP10
TP30 IC 2 16 MCLK 15 OFHK 14 RGDT/FSD FSYNC SCLK 13 M0 VD 12 VA SDO 11 GND SDI 10 C1A M1 FC/RGDT 9 AOUT RESET Si3021-FS
16 15 14 13 12 11 10 9 FILT2 FILT RX REXT REXT2 REF VREG2 VREG K QE2 DCT IGND C1B RNG1 RNG2 QB QE
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
78.7F(1608)
R15 120K(1608)
RL Z5.6
DAAGND DAAGND C14 B0.22u/ 16V(1608) DAAGND TP21 TPGND 0R 1/4W (N.M.) SPOUT
402F(1608)
AK
TP6 D1 D AN217 A ZD2
1.7 8kF 2W
ZD3 R D43FM
B1800p/50V(1608)
9 .31kF(1608)
C 22
R1002
B0.1u/16V(1608)
D2 D AN217
B0.1u/16V(1608)
AK
N.M.(KH)
TP5
C163
215F(1608)
R2
TP31 R 46 C2
R1001
C1002 B0.68u/16V(2125)
ZD1
3
C16 N.M.(5750) 680 1/10W(1608) R4 TP19 150p(KH) A4.7uF/50V(NP) C5 33pF FB1 BLM31A601S L1 TP17 TP8 TWKA151KNP R1004 56k 1/10W(2125) C1005 B560p/250V(2125) C1006 N.M. (3216) C16A
Q1001 2SC4548(E)
TP32
C 19 B0.022u/250V(2125)
G ND
C8
L4
MJ1
SBT-0260
R7 10R 1/4W
SA2
R6 10M(1608)
L1 L2
D3
L5
L2 TWKA102KNP
C6 N.M.(5750)
1 2 3 4 5 6
C6A 1000pF(KH)
SBT-0260 VA1
MJ-64J-RD315
DSS-401M
SA3 DSS-301L
FL1 ST110AV
3
DSS-301L(N.M.) S1ZB60 R1003 56k 1/10W(2125) C1004 B560p/250V(2125) TP34 C1003 N.M. (3216)
SA1
DSS-401M
C7 N.M.(5750)
C7A 1000pF(KH)
C 23 33pF
FB2 BLM31A601S L3
R 19 10M(1608)
C24
A4.7uF/50V(NP)
+24V
R91 0R(1608)
TP18 R18 680 1/10W(1608) IC 3 +5V D6 TP174 TP175 C42 F0.1uF/16V HS1_L HS2_L R Y1 B 1SS355
G ND G ND
3 9 K 1W PC1A
MJ2
2
VCC OUT1 OUT2 AOUT GND 7 6 5 4 3
H1
+
RSB-24
16
Q9 DTC123JKA B
13
R Y1 A RSB-24
4
G ND G ND
11
C44 R52
Z D5 MTZJ30B C ID_L
C68 0.1uF
G ND
L7
1 2 3 4 5 6
SBT-0260
MJ-62J-RD315
L6
SBT-0260
2/6
5 6k 5 6k 5 6k 5 6k
D
C145 100pF
SPOUT
TP317
C135 0.1uF TP321 IC12 C134 0.1uF IC11 C132 F0.1u/16V R166 TP336
BZ
TP324 R176
20k
TP323
3 X 3 4 2 3 1 7 8
TP333 C144 A4.7u/50V C133 F0.1u/16V C143 A4.7u/50V R180 22k AG SPMUTE TP330 +5V C142 A4.7u/50V TP332
TP300
TP305
R162
3.3K
TP301
TP304
R179 3.3k
SP OUT
5
TP334 IC13 NJM2113M R184 0R
C N4
1 2
B2B-PH-K-S
C136
R175 1.6k
C139
13 14 15 12 1 5 2 4 X0 X1 X2 X3 X4 X5 X6 X7 VDD
C137 0.1uF
16 VDD 16
4700pF TP316
2200pF
6 11 10 9
AG
AG
+5V
R169 4.7k
AG
VOLCNT_A
4. 7k
R158
R156
4. 7k R155
4. 7k
VOLCNT_B
VOL_A
TP314
VOL_B
TP309
VOL_C
TP308
FAX MAIN PWB (SRAM & FLASHROM (16M)) (Europe, Australia, New Zealand)
3/6
D[7:0]
A[21:0] A0
D
IC10 IC 9
29 28 27 26 25 23 22 21
D7 D6 D5 D4 D3 D2 D1 D0
NC
BAT
DQ15 DQ14 DQ13 DQ12 DQ11 DQ10 DQ9 DQ8 DQ7 DQ6 DQ5 DQ4 DQ3 DQ2 DQ1 DQ0 RY/BY BYTE VPP VCC 13 37 15 47
45 43 41 39 36 34 32 30 44 42 40 38 35 33 31 29
VCC
C76 0.1uF + TP325 F_WP CS_FL RESETL C75 100pF A21 MBM29LV160BE90TN R100 75 G ND TP117 C77 47u/25V
CS_S0L CS_S1L
A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1
9 16 17 48 1 2 3 4 5 6 7 8 18 19 20 21 22 23 24 25 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0
26 12 28 11 14 10 CE RP OE WE WP NC GND GND 27 46
C
G ND OEL WEL
+3.3V
BAT TP83 R81 10k RTC_DATA RTC_CLK TP89 TP88 RTC_CE0H TP86 TP85
+3.3V
IC 6 C61 C60
7 6 5 1
8
12pF 12pF
BAT
3 2 4
C65 F0.1u/16V R87 10k X2 DT-38 32.768KHz
R47 560
G ND
Q7 KTA1504 G ND
TP77
CS_S1L
R68 1k
G ND
Z D4 UDZ2.0B
Q6 KTA1504
TP82
TP79
R44 20k
B
VCC
PST3426
R45 1k
C40 0.1uF
D4 1SS355
G ND
B
G ND G ND
TP80
R24 1k
Q8 KTC3875
R69 1k
G ND
BT1 HL50-A
JP3
0R
Q1 DTC363EKA C B
G ND
G ND
G ND
+3.3V
4/6
D
+3.3V +3.3V MDM3.3V C98 A47u/25V F L7 FL10 F L6 F L5 F L2 F L8 FL14 F L9 F L4 F L3 +3.3V G ND
C39 A47u/25V
G ND +3.3V
+3.3V
R61
4.7k
MDM_IRQ C LKIN R59 33 MDM3.3V G ND MDM3.3V R58 33 X1 SCO10-24.576000MHz-3.3V TP57 3 OUT OE 1 FB2001 ACH32(N.M.)
TP75
R62
0R
TP72
C55 0.1uF C57 0.1uF C35 0.1uF C48 0.1uF C51 0.1uF C53 0.1uF C29 A22u/16V C30 0.1uF C31 0.1uF
C
34 92 78 68 44 30 15 3 55 54 97 86 62 42 21 9 53 52
G ND
C33 0.1uF C34 1uF(1608) C54 0.1uF C52 0.1uF C50 1uF(1608) C32 1uF(1608) C36 0.1uF C38 0.1uF C56 0.1uF C49 1uF(1608)
2 GND
C69 C470/16V C70 F0.1u/16V
IC 5
VDD
FL13 ZJSR5101(22000p)
1 T3IRQ
TP61 R57 47K TP60
AVDD
VDDREG VDDREG
MDM3.3V
R37 R38
47K 47K
REGOUT REGOUT
26 27 36 33 31 29 28
TP59
G ND
G ND
M_RESETL
41 CXIN CXOUT CLKOUT CNT LON SCANNT MINTEST INTEST MODE0 MODE1
MN195006E
C47 100pF
39 38 43 37 51 45 46 48 49 50 57 58
G ND TP37 TP38 TP41 TP39 R33 0R
G ND
A[21:0]
A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0
100 98 96 95 94 93 91 90 88 87 85 84 DPA11 DPA10 DPA09 DPA08 DPA07 DPA06 DPA05 DPA04 DPA03 DPA02 DPA01 DPA00 EYECLK EYEDAT 1 2 3 4 5 6
A2-6PA-2.54DSA(NM)
R28 47K
R29 47K
R31 47K R13 R30 R12 100 100 100 TP28 TP47 TP43 TP26 ABITCLK ASPCLK ATXD ARXD
AVSS
35
99 89 80 70 64 56 47 40 32 23 17 11 5
VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS
D[7:0]
MNR04 33 8 7 6 5 BR7 1 2 3 4
59 60 63 61
B
GPIO0 GPIO1 GPIO2 GPIO3 GPIO4 GPIO5 76 77 79 81 82 83
R41 R42 R64 47K 47K 47K
MDM3.3V
MNR04 33
65 66 69 67
R32 47K
B
G ND
BR1 TP242 D7 1 TP239 D6 2 TP212 D5 3 TP211 D4 4 TP220 D3 TP218 D2 TP216 D1 TP214 D0 R97 47K R98 47K R99 47K R101 47K R102 47K R103 47K R104 47K R60 47K TP63 25 TP62 24 TP64 22 TP65 20 TP101 19 TP102 18 TP103 16 TP104 14 TP105 13 TP107 12 TP109 10 TP111 8 TP113 7 TP115 6 TP116 4 TP73 2
DPD15 DPD14 DPD13 DPD12 DPD11 DPD10 DPD09 DPD08 DPD07 DPD06 DPD05 DPD04 DPD03 DPD02 DPD01 DPD00
G ND
5/6
D
PB_D0 PB_D1 PB_D2 PB_D3 PB_D4 PB_D5 PB_D6 PB_D7 FL17 IC 8 C83 F0.1u/16V TP183 TP181 G ND MCU_INT MCU_CEL MCU_OEL FL12 C82 F0.1u/16V G ND (N.M.) +3.3V (N.M.) +3.3V
BR17 MNR04 47 1 8 2 7 3 6 4 5
1 BR16 2 MNR04 47 3 4
8 7 6 5
+3.3V
BR24
1 2 3 4
TP187 TP269 TP191 TP190 TP171 TP172 TP173 TP168 BR5 MNR04 1 2 3 4 M CU_D0 M CU_D1 M CU_D2 M CU_D3 0R 8 7 6 5 BR3
8 7 6 5
MNR04 22K +3.3V R108 +3.3V MNR04 0R WEL +3.3V C84 F0.1u/16V RESETL G ND TP268 RGDTTP262 TP261 FL18 (N.M.) 10K TP176
1 2 3 4
8 7 6 5
BR22
MNR04 22K
PB_A7 PB_A6 PB_A5 PB_A4 PB_A3 PB_A2 PB_A1 PB_A0 TP169 TP170 TP166 TP167
(N.M.)
+3.3V
BR23
1 2 3 4
8 7 6 5
1 2 3 4
1 2 3 4
10K 10K 10K 10K
8 7 6 5
MNR04 (N.M.)
C
D8 DA204U R138 R144 R143 TP267 TP266 +3.3V C107 F0.1u/16V R136 G ND R135 TP256 TP254 TP331 C_BT L_BTTP252 10K R132 S +3.3V FL22 (N.M.) 100 BZ TP251 TP328 TP249 R134 G ND M_RESETL 10K TP258 TP257 10K TP255 uPD65 9 44GM-P07-JED-A FL19 (N.M.) 10K 10K 10K BR2 9 MNR04 10K 1 8 2 7 3 6 4 5
MNR04 (N.M.)
C
+3.3V R76 TP161
BR6
TP165 R86 TP90 R83 TP164 R84 TP162 R82 TP163 RTC_CE0H RTC_CLK RTC_DATA CS_S0L CS_FL
1 2 3 4
8 7 6 5
MNR04 10K
10K(N.M.) CS_OP1L TP159 CS_OP2L TP158 TP157 TP156 TP155 TP154 R79 R74 R72 R71 0R A21 C64 18pF FL16 R107 100 C80 F0.1u/16V BR13 G ND (N.M.) +3.3V C62 18pF C59 18pF 100 100 100 CS_ML OEL WEL
JP2
R70 R106
10K 10K
T2B-SQ
BR 9
1 2 3 4
G ND
1 2 3 4 5 6 7 BR18 8 MNR04 0R 1 9 8 10 2 7 11 6 3 12 5 4 13 1 8 14 2 7 15 3 6 16 4 5 BR1 9 MNR04 0R 17 18 19 20 21 22 23 R114 33 24 W AKE_UP 25 26 27 28 EXHKD_L 29 30 31 HS2_L 32 CID_L 33 HS1_L 34 35 F _ R YB Y 36 37 R140 10K TP263 38 TP260 39 R142 10K 40 VDD PB_DAT_05 PB_DAT_04 PB_DAT_03 PB_DAT_02 PB_DAT_01 PB_DAT_00 TESTMODE0 PB_ADDR_07 PB_ADDR_06 PB_ADDR_05 PB_ADDR_04 PB_ADDR_03 PB_ADDR_02 PB_ADDR_01 PB_ADDR_00 PB_CE2_N PB_CE1_N PB_AE0_N VDD GND PB_WR_N PB_OE_N RESET_N WAKE_UP FGPI_07 FGPI_06 FGPI_05 FGPI_04 FGPI_03 FGPI_02 FGPI_01 FGPI_00 FGPIO_07 FGPIO_06 FGPIO_05 FGPIO_04 TCK TRST VDD GND GND PB_DAT_06 PB_DAT_07 CPU_INT_N CPU_CS_N CPU_RD_N VDD GND CPU_DT_00 CPU_DT_01 CPU_DT_02 CPU_DT_03 GND CPU_DT_04 CPU_DT_05 CPU_DT_06 CPU_DT_07 VDD GND FAXWRIN_N UART_RTS UART_CTS UART_SOUT UART_SIN RTC_ION RTC_CE RTC_SCLK RTC_SDATA FAXCS_N_00 FAXCS_N_01 FAXCS_N_02 FAXCS_N_03 FAXCS_N_04 FAXCS_N_05 FAXOE_N FAXWR_N FAXADD_21 GND GND
160 159 158 157 156 155 154 153 152 151 150 149 148 147 146 145 144 143 142 141 140 139 138 137 136 135 134 133 132 131 130 129 128 127 126 125 124 123 122 121
1 2 3 4
8 7 6 5
BR10
MNR04 10K
G ND
BR11
1 2 3 4
8 7 6 5
MNR04 10K
1 2 3 4
8 7 6 5
BR25
MNR04 10K
1 2 3 4
8 7 6 5
PB_D7 TP273 PB_D6 TP278 PB_D5 TP274 PB_D4 TP279 PB_D3 TP275 PB_D2 TP280 PB_D1 TP276 PB_D0 TP281 PB_A7 TP195 PB_A6 TP179 PB_A5 TP180 PB_A4 TP192 PB_A3 TP193 PB_A2 TP182 PB_A1 TP188 PB_A0 TP194 PB_CS1L PB_AE0L PB_WEL PB_OEL D7 D6 D5 D4 D3 D2 D1 D0 A21 TP106 A20 TP112 A19 TP110 A18 TP114 A17 TP127 A16 TP134 A15 TP121 A14 TP125 A13 TP130 A12 TP131 A11 TP122 A10 TP124 A9 TP129 A8 TP132 A7 TP123 A6 TP126 A5 TP128 A4 TP133 A3 TP213 A2 TP215 A1 TP217 A0 TP219
1 2 3 4
MNR04 10K
(N.M.)
+3.3V
BR2
BR4
1 2 3 4
8 7 6 5
+3.3V G ND
B
+ C109 A47u/25V +3.3V +3.3V R126 TP223 TP235 TP234 R124 10K G ND C101 100pF 10K R122 10K R127 10K(N.M.) +3.3V G ND
1 2 3 4
8 7 6 5
MNR04 (N.M.)
M CU_D7 M CU_D6 M CU_D5 M CU_D4 M CU_D3 MNR04 (N.M.) M CU_D2 M CU_D1 M CU_D0 R90 22K M CU_INT R89 22K TP290 MCU_CEL R88 22K TP294 MCU_OEL
R85 R75
10K 10K
WEL OEL
TP119 TP118
MNR04 100 BR27 TP151 1 A3 8 TP144 2 A2 7 TP231 3 A1 6 TP224 4 BR28 A0 5 TP228 D0 1 8 TP225 MNR04 100 2 D1 7 TP229 D2 3 6 TP226 D3 4 5 TP221 R120 100 D4 TP222 R121 100 MNR04 100 D5 TP227 R125 0R(N.M.) TP233 TP230
41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 GND GND TMS NC TDI TDO FGPIO_03 FGPIO_02 FGPIO_01 FGPIO_00 TELELIN BEEP_O_V1 BEEP_O_V2 FGPO_15 FGPO_14 FGPO_13 FGPO_12 GND FGPO_11 FGPO_10 FGPO_09 FGPO_08 GND VDD FGPO_07 FGPO_06 FGPO_05 FGPO_04 FGPO_03 FGPO_02 FGPO_01 FGPO_00 FAX_DATA_07 FAX_DATA_06 VDD GND XIN XOUT GND GND
VDD FAXADD_20 FAXADD_19 FAXADD_18 FAXADD_17 FAXADD_16 FAXADD_15 FAXADD_14 GND FAXADD_13 FAXADD_12 FAXADD_11 FAXADD_10 FAXADD_09 FAXADD_08 FAXADD_07 FAXADD_06 FAXADD_05 FAXADD_04 GND VDD FAXADD_03 FAXADD_02 FAXADD_01 FAXADD_00 FAX_DATA_00 FAX_DATA_01 FAX_DATA_02 FAX_DATA_03 FAX_DATA_04 FAX_DATA_05 TMD0_OUT TOUT TESTB TMD2 TMD1 TMD0 SYSCLK_IN CLKSEL VDD
120 119 118 117 116 115 114 113 112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
R137 R141
7.5k 10k
R123 10K
TP264
C ID_L EXHKD_L
G ND
FL20
(N.M.)
+3.3V
G ND
G ND
22K 10K
TP270 TP250
C102 A47u/25V
G ND IC 7 C LKIN R95 TP99 C73 F0.1u/16V G ND G ND TP98 C72 270pF 510 TP95 TP96 TP97 R2001 0R C71 F0.1u/16V TP232 R128 0R C104 100pF TP236 R129 75 G ND G ND
A
1 2 3 4 Xin Xout S1 LF
P2782A-08SR
A
8 7 6 5
G ND
6/6
4 3 2 1
C92 A47u/35V + FB2002 ACH32(N.M.) #MDM_IRQ #RESET#PB_nOE #PB_nWE #PB_nAE0 #PB_nCS1 +3.3V TP3.3V LC3S-Y(N.M.) IN3.3V +5V IN5V +24V IN24V
5 6 7 8 5 6 7 8
33pF 33pF 100pF 33pF FB3 MNR04 33 + FB2004 ACH32(N.M.) + FB2003 ACH32(N.M.)
4 3 2 1
D
10p/50V 1000pF D7 C 85 C 87 C116 C117 C118 C120 A47u/25V C 90 F0.1u/16V C 89 1000p(N.M.) C 88 F0.1u/16V C 93 A47u/25V C 94
BR20 MNR04 0R
1SS355(N.M.)
G ND G ND G ND G ND G ND
G ND
G ND
PB_A[7:0]
5 6 7 8
33pF 33pF 33pF 33pF 33pF 33pF 33pF 33pF FB7 MNR04 33
4 3 2 1
40
C112
C113
C114
C11 9 C115
C146
C147
C148
C
G ND
IN5V #MDM_IRQ #PB_nOE #PB_nAE0 #PB_A0 #PB_A2 #PB_A4 #PB_A6 #PB_D0 #PB_D2 #PB_D4 #PB_D6 #MCU_INT #MCU_nOE #MCU_D1 #MCU_D3 #MCU_D5 #MCU_D7
39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1
IN3.3V IN 24V #RESET#PB_nWE #PB_nCS1 #PB_A1 #PB_A3 #PB_A5 #PB_A7 #PB_D1 #PB_D3 #PB_D5 #PB_D7 #MCU_nCS #MCU_D0 #MCU_D2 #MCU_D4 #MCU_D6 B40B-PNDZS-1
40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2
FB8 MNR04 5 6 7 8
G ND
5 6 7 8
33pF 33pF 33pF 33pF 33pF 33pF 33pF 33pF FB9 MNR04 33
4 3 2 1
C155
C14 9 C150
C151
C156
C152
C153
C154
10p/50V
10p/50V
10p/50V
C121
C122
C123
10p/50V(N.M.)
10p/50V(N.M.)
10p/50V(N.M.)
10p/50V(N.M.)
10p/50V(N.M.)
10p/50V(N.M.)
10p/50V(N.M.)
10p/50V(N.M.)
C124
C125
C126
C128
C127
C157
C158
G ND
C160
B
G ND +3.3V C46 0.1uF TP94 R56 22 G ND +3.3V C58 0.1uF TP74 R65 22 G ND +3.3V C63 0.1uF TP84 R73 22 G ND +3.3V C66 0.1uF TP91 R93 22 G ND +3.3V C67 0.1uF TP92 R94 22 G ND +3.3V C74 0.1uF TP100 R96 22 G ND +3.3V C78 0.1uF TP120 R105 22 G ND
R150 R151
0R 0R
MCU_D[7:0]
+3.3V
+3.3V
+3.3V
+3.3V
+3.3V
+3.3V
+3.3V
5 6 7 8
4 3 2 1
FB10 MNR04 100
1/1
4
D401
CN401
KEY412
S/SK OT6K
SKQNABD010 SKQNABD010 SKQNABD010 SKQNABD010 SKQNABD010
OT5K
SKQNABD010
D402
SKQNABD010
3. FAX OPERATION
1SS133
KEY408
KEY407
KEY406
KEY405
KEY404
KEY403
KEY402
BCK
D403 LED401 SKQNABD010 SKQNABD010 SKQNABD010 SKQNABD010 SKQNABD010
CSK
OT8K
SKQNABD010
R/PK
SKQNABD010
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
F-KEYSC3 F-KEYSC2 F-KEYSC1 F-KEYIN7 F-KEYIN6 F-KEYIN5 F-KEYIN4 F-KEYIN2 F-KEYIN3 F-KEYIN1 LED_V3 LED_V2 LED_V1 DATA1 TP1
BM15B-GHS-TBT LTL-1LHG-002A
LSL
1SS133 KEY411 KEY410 KEY421 KEY420 KEY419
KEY409
KEY401
MEMK SPKK
SKQNABD010 SKQNABD010 SKQNABD010 SKQNABD010
OT1K
OT3K
RESOK
SKQNABD010
SFTK
SKQNABD010
RMODK
SKQNABD010
3
LED403
SFTL
LTL-1LHG-002A
LED402
MEML
LTL-1LHG-002A
LEAD-FREE SOLDER
The PWBs of this model employs lead-free solder. The LF marks indicated on the PWBs and the Service Manual mean Lead-Free solder. The alphabet following the LF mark shows the kind of lead-free solder.
Example:
<Solder composition code of lead-free solder> Solder composition code (Refer to the table at the right.) Solder composition Sn-Ag-Cu Sn-Ag-Bi Sn-Ag-Bi-Cu Sn-Zn-Bi Sn-In-Ag-Bi Sn-Cu-Ni Sn-Ag-Sb Bi-Sn-Ag-P Bi-Sn-Ag Solder composition code a b z i n s p
Lead-Free
5mm
(German) Achtung Explosionsgefahr bei Verwendung inkorrekter Batterien. Als Ersatzbatterien drfen nur Batterien vom gleichen Typ oder vom Hersteller empfohlene Batterien verwendet werden. Entsorgung der gebrauchten Batterien nur nach den vom Hersteller angegebenen Anweisungen.
Trademark acknowledgements
Microsoft, Windows, Windows 98, Windows Me, Windows 2000, Windows XP, Windows Vista and Internet Explorer are registered trademarks or trademarks of Microsoft Corporation in the U.S.A. and other countries. Adobe, the Adobe logo, Acrobat, the Adobe PDF logo, and ReaderTM are registered trademarks or trademarks of Adobe Systems Incorporated in the United States and other countries. IBM, PC/AT, and PowerPC are trademarks of International Business Machines Corporation. Sharpdesk is a trademark of Sharp Corporation. All other trademarks and copyrights are the property of their respective owners.
SHARP CORPORATION Digital Document System Group CS Promotion Center Yamatokoriyama, Nara 639-1186, Japan
2008 April Printed in Japan