Вы находитесь на странице: 1из 52

ELECTRICAL SOLUTIONS

A. System Overview

WIRING DUCT
From the smallest wall mounted panels to the largest integrated turnkey systems PANDUIT PANDUCT Wiring Duct is the premium wire management solution for routing and concealing wiring in electrical control panels. PANDUCT Wiring Duct provide solutions for the original equipment manufacturing, transportation, contract manufacturing, maintenance and repair and communications markets. All PANDUCT Wiring Duct are UL Recognized and CSA Certified and most carry the CE mark.

B1. Cable Ties

B2. Cable Accessories

B3. Stainless Steel Ties

Some of the features and benefits found in PANDUCT Wiring Duct include: Smooth corners and edges that will not abrade wiring or irritate hands Integrated nonskid liners and unique cover designs insure the duct cover will not slide once installed or during vibration Specially formulated lead-free PVC material meets the NFPA79: 2007 flame retardancy requirements and carries a UL 94V-0 flammability rating Scorelines for easy removal of duct fingers and sidewalls Accessories and tools that increase productivity and lower the installed cost
PANDUIT continues to develop new PANDUCT Wiring Duct solutions to satisfy the challenges facing our customers worldwide. The new type HN hinged cover wiring duct features narrow slots for excellent high-density wire management. Plus the exclusive hinged cover provides convenient channel access resulting in up to 20% faster wiring changes for reduced labor costs. Maximize the utilization of enclosure space with PANELMAX Corner Wiring Duct, which fits into the corner of enclosures and provides up to five square feet of additional subpanel space for mounting control components or up to 20% savings in enclosure footprint area.

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.1

ELECTRICAL SOLUTIONS
A. System Overview

Wiring Duct for Control Panel Applications


B1. Cable Ties

B2. Cable Accessories

5 3

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

2 A

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

For information on FL Wiring Duct and other PANDUCT Accessories see pages C1.25 C1.32

C1.2

ELECTRICAL SOLUTIONS
A. System Overview

B1. Cable Ties

PANDUCT PANELMAX Corner Wiring Duct (pages C1.4 C1.5)

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

PANDUCT Type H Wide Slot and HN Narrow Slot Hinged Cover Wiring Duct (pages C1.6 C1.7)

C2. Surface Raceway

C3. Abrasion Protection

PANDUCT Type F Narrow Slot Wiring Duct (pages C1.10 C1.11)

C4. Cable Management

D1. Terminals

D2. Power Connectors

PANDUCT Type G Wide Slot Wiring Duct (pages C1.8 C1.9)

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

PANDUCT Type MC Metric Wiring Duct (pages C1.14 C1.15)

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

PANDUCT Type D Flush Cover Round Hole Wiring Duct (pages C1.12 C1.13)

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.3

ELECTRICAL SOLUTIONS
A. System Overview

Features and Benefits PANDUCT PANELMAX Corner Wiring Duct


One-piece base reduces fasteners required for minimal installation time

B1. Cable Ties

Conventional Wiring Duct


Co-extruded hinged base sits flat for cutting and also conforms to corner for installation Unused Panel Space

B2. Cable Accessories

B3. Stainless Steel Ties

Enclosure corner top view

Space is lost at the edges of the mounting panels.

C1. Wiring Duct

C2. Surface Raceway

Upper and lower scorelines allow easy finger and sidewall section removal

Space Savings with PANELMAX Corner Wiring Duct


Integral divider wall mount feature in base Panel Space Gain

Up to 5 square feet of additional mounting space gained per enclosure.*

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

D2. Power Connectors

Specially formulated lead-free PVC material

Both sizes use 2 inch Type C cover (C2)

Up to a 20% reduction in enclosure footprint size is possible vs. a conventional wiring duct installation.*

D3. Grounding Connectors

E1. Labeling Systems

PANDUCT Nylon Rivets Fast, lowest cost mounting method. See page C1.34.

PANDUCT Installation Tools Wide selection of hand tools for cutting and installing wiring duct. See page C1.34.

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

PANDUCT Type C Cover with Protective Film Reduces scrap and labor costs by protecting the surface during storage, handling, and installation. See page C1.5.

PANDUCT Divider Wall Creates separate wiring channels within the wiring duct base. Available in solid or slotted wall styles. See page C1.26.

*Actual subpanel space savings will vary depending on wiring duct size, component layout, and enclosure size and type. Footprint savings is based on commercially available enclosures and may not be achievable in some applications.

C1.4

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANELMAX Corner Wiring Duct
Fits in the unused space in the vertical corner of enclosures, gaining subpanel space or saving enclosure footprint area One-piece base requires less time to install than multi-piece solutions Optional quick mount clips engage anywhere along the product base further reducing assembly costs PANDUIT divider wall snaps directly to the integrated mounting feature in the channel to create two separate channels Compatible with PANDUIT 3 inch and 4 inch height wiring duct; both product sizes uses standard 2 inch wiring duct cover Base and cover length is 6 feet
A. System Overview

B1. Cable Ties

B2. Cable Accessories

Base Part Number CWD3LG6 CWD4LG6 CWD3WH6 CWD4WH6

Duct Size W x H (In.) 4.40 x 3.57 5.33 x 4.58 4.40 x 3.57 5.33 x 4.58

Slot Width In. .20 .20 .20 .20 mm 5.0 5.0 5.0 5.0

Cover Part Number C2LG6 C2LG6 C2WH6 C2WH6

Std. Base Cover Pkg. Ctn. Ctn. Qty. Qty. Qty. 6 24 120 6 24 120 6 24 120 6 24 120

B3. Stainless Steel Ties

C1. Wiring Duct

Part number shown in LG (Light Gray) color, also available in WH (White) color. Product available in 6' lengths.

C2. Surface Raceway

.50 TYP [12.7]


C3. Abrasion Protection
H

C4. Cable Management

.20 TYP [5.0]


D1. Terminals

D2. Power Connectors

To order cover with protective film add F to part number. 6" inch cover not available with protective film.

D3. Grounding Connectors

Part Number

Part Description L-bracket with quick mounting clip for installing CWD3 to back panel only. L-bracket with quick mounting clip for installing CWD4 to back panel only. Quick mounting clip for installing CWD3 corner wiring duct. Quick mounting clip for installing CWD4 corner wiring duct.

Fastener Size #10-32 x 1/4 (user supplied) #10-32 x 1/4 (user supplied) #10-32 x 1/4 (user supplied) #10-32 x 1/4 (user supplied)

Std. Pkg. Qty. 16 16 16 16

Std. Ctn. Qty.

E1. Labeling Systems

Quick Mount Clips


CDLB3 CDLB CDLB4 CDCLP3 CDCLP4 CDCLP

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.5

ELECTRICAL SOLUTIONS
A. System Overview

Features and Benefits PANDUCT Type H and HN Hinged Cover Wiring Duct
Available in eight sizes from 1.5" x 2" up to 4" x 4" in light gray, black, and white colors.

B1. Cable Ties

B2. Cable Accessories

Dual-sided hinge cover opens up to 100 from either sidewall of duct for up to 20% faster wiring changes Cover retention flange enables simple push-on installation, saving time and hassle

Cover removal rib eases cover opening for quick channel access during wiring changes

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

Robust channel profile withstands a side impact force up to two times greater than conventional wiring duct

C3. Abrasion Protection

C4. Cable Management

Upper and lower scoreline allows easy fingers and sidewall section removal saving installation time

Specially formulated lead-free PVC material

Labor Savings
D1. Terminals

By avoiding the time and hassle in removing and replacing covers, simple wiring changes can be made up to 20% faster compared to conventional wiring duct installations*

D2. Power Connectors

Avoid Cover Replacement Costs

% of Wiring Duct Cost

Covers represent 20% of the cost of the wiring duct purchase Misplaced covers are a common occurrence after years of use Not needing to remove covers during maintenance ensures better aesthetics and safety and avoids the cost to replace lost covers 0% 20% 40% 60% 80% 100%

D3. Grounding Connectors

Base

Cover

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

PANDUCT Wire Retainers Contain wiring when duct cover is opened. Wire retainers snap easily between duct fingers. See page C1.28.

PANDUCT Divider Wall Create separate wiring channels within the wiring duct base. Available in solid or slotted wall styles. See page C1.26.

PANDUCT Installation Tools Wide selection of hand tools for cutting and installing wiring duct. See page C1.34.

PANDUCT Nylon Rivets Fast, lowest cost mounting method. See page C1.34.

*Based on mock panel installations of type H hinged cover wiring duct and other commonly available wiring ducts adding a single component with four wires.

C1.6

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANDUCT Type HN Hinged Cover Narrow Slot Wiring Duct
Narrow slot/finger design provides excellent wire management with smaller wire diameters and high-density components such as terminal blocks, input/output devices, and other hardware Material: Lead-free PVC UL Recognized continuous use temperature: 122F (50C) Base Part Number HN1.5X2LG6 HN1.5X3LG6 HN2X2LG6 HN2X3LG6 HN2X4LG6 HN3X3LG6 HN3X4LG6 HN4X4LG6 UL 94 flammability rating of V-0 Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material Provided with mounting holes Base and cover length is 6 feet Slot Width In. mm .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 5.0 Cover Part Number HC1.5LG6 HC1.5LG6 HC2LG6 HC2LG6 HC2LG6 HC3LG6 HC3LG6 HC4LG6 Std. Base Cover Pkg. Ctn. Ctn. Qty Qty. Qty. 6 120 120 6 120 120 6 120 120 6 60 120 6 60 120 6 60 120 6 60 120 6 60 60
A. System Overview

B1. Cable Ties

.50 TYP [12.7]

Duct Size W x H* In. mm 1.75 x 1.98 44.5 x 50.3 1.75 x 3.06 44.5 x 77.7 2.17 x 1.98 55.1 x 50.3 2.17 x 3.06 55.1 x 77.7 2.17 x 4.10 55.1 x 104.1 3.25 x 3.06 82.6 x 77.7 3.25 x 4.10 82.6 x 104.1 4.25 x 4.10 108.0 x 104.1

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

.20 TYP [5.0]


Multiple slot restrictors present with 2" and greater duct wall height.

Part Number shown for LG (Light Gray). Available in WH (White). Base and cover sold separately. *H dimension includes duct and cover.

C2. Surface Raceway

PANDUCT Type H Hinged Cover Wide Slot Wiring Duct


Wide slot/finger design provides excellent wire management in general purpose applications and is compatible a wide range of wire sizes and component types Material: Lead-free PVC Rated for continuous use temperature: 122F (50C) Base Part Number H1.5X2LG6 H1.5X3LG6 H2X2LG6 H2X3LG6 H2X4LG6 H3X3LG6 H3X4LG6 H4X4LG6 UL 94 flammability rating of V-0 Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material Provided with standard mounting holes Base and cover length is 6 feet Slot Width In. mm .31 7.9 .31 7.9 .31 7.9 .31 7.9 .31 7.9 .31 7.9 .31 7.9 .31 7.9 Cover Part Number HC1.5LG6 HC1.5LG6 HC2LG6 HC2LG6 HC2LG6 HC3LG6 HC3LG6 HC4LG6 Std. Base Cover Pkg. Ctn. Ctn. Qty Qty. Qty. 6 120 120 6 120 120 6 120 120 6 60 120 6 60 120 6 60 120 6 60 120 6 60 60

C3. Abrasion Protection

C4. Cable Management

Duct Size W x H* In. mm 1.75 x 1.98 44.5 x 50.3 1.75 x 3.06 44.5 x 77.7 2.17 x 1.98 55.1 x 50.3 2.17 x 3.06 55.1 x 77.7 2.17 x 4.10 55.1 x 104.1 3.25 x 3.06 82.6 x 77.7 3.25 x 4.10 82.6 x 104.1 4.25 x 4.10 108.0 x 104.1

D1. Terminals

D2. Power Connectors

E
W

E F For 2" duct height: .31" [7.9] .80" [20.3] 3" to 4" duct height: .31" [7.9] 1.00" [25.4]

Part Number shown for LG (Light Gray). Available in BL (Black) and WH (White). Base and cover sold separately. *H dimension includes duct and cover.

D3. Grounding Connectors

PANDUCT Type HS Hinged Cover Solid Wall Raceway


Solid wall raceway conceals and protects wiring in continuous runs such as in low-voltage cord management applications between control panel stations in conveyor systems Material: Lead-free PVC UL recognized continuous use temperature: 122F (50C) UL 94 flammability rating of V-0 Supplied without mounting holes Base and cover length is 6 feet Cover Part Number HC1.5LG6 HC1.5LG6 HC2LG6 HC2LG6 HC2LG6 HC3LG6 HC3LG6 HC4LG6 Std. Base Cover Pkg. Ctn. Ctn. Qty. Qty. Qty. 6 120 120 6 60 120 6 120 120 6 60 120 6 60 120 6 60 120 6 60 120 6 60 60

E1. Labeling Systems

E2. Labels

Base Part Number HS1.5X2LG6NM HS1.5X3LG6NM HS2X2LG6NM HS2X3LG6NM HS2X4LG6NM HS3X3LG6NM HS3X4LG6NM HS4X4LG6NM
H

Duct Size (W x H)* In. mm 1.75 x 1.98 44.5 x 50.3 1.75 x 3.06 44.5 x 77.7 2.17 x 1.98 55.1 x 50.3 2.17 x 3.06 55.1 x 77.7 2.17 x 4.10 55.1 x 104.1 3.25 x 3.06 82.6 x 77.7 3.25 x 4.10 82.6 x 104.1 4.25 x 4.10 108.0 x 104.1

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

Part Number shown for LG (Light Gray). For BL (Black) and WH (White) colors see color selection guide, page C1.48. Base and cover sold separately. *H dimension includes duct and cover.

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.7

ELECTRICAL SOLUTIONS
A. System Overview

Features and Benefits PANDUCT Type G Wide Slot Wiring Duct


Available in 36 sizes from .5" x .5" up to 6" x 4" in a variety of colors.

B1. Cable Ties

B2. Cable Accessories

Exclusive PANDUIT smooth rounded edges prevents wiring abrasion

Non-slip cover liner prevents cover slide

Flush cover design provides a neat and finished appearance

B3. Stainless Steel Ties

Specially formulated lead-free PVC material

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

Upper and lower scorelines allows easy finger and sidewall section removal saving installation time

Restricted slot design retains wires, eliminating hassle and saving time

Wide finger/slot design provides greater rigidity and allows use with a wide range of wire and bundle sizes

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

PANDUCT Wire Retainers Contain wiring when duct cover is opened. Wire retainers snap easily between duct fingers. See page C1.28.

PANDUCT Divider Wall Create separate wiring channels within the wiring duct base. Available in solid or slotted wall styles. See page C1.26.

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

PANDUCT Type C Cover with Protective Film Reduces scrap and labor costs by protecting the surface during storage, handling, and installation. See page C1.9.

PANDUCT Nylon Rivets Fast, lowest cost mounting method. See page C1.34.

PANDUCT Installation Tools Wide selection of hand tools for cutting and installing wiring duct. See page C1.34.

C1.8

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANDUCT Type G Wide Slot Wiring Duct
Wide slot/finger design provides greater sidewall rigidity and can be used with a wide range of wire bundle sizes Material: Lead-free PVC UL recognized continuous use temperature: 122F (50C) UL 94 flammability rating of V-0 Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material Provided with mounting holes Base and cover length is 6 feet
A. System Overview

B1. Cable Ties

B2. Cable Accessories

Base Part Number G.5X.5LG6 G.5X1LG6 G.5X2LG6 G.5X4LG6 G.75X.75LG6 G.75X1LG6 G.75X1.5LG6 G.75X2LG6 G1X1LG6 G1X1.5LG6 G1X2LG6 G1X3LG6 G1X4LG6 G1.5X1LG6 G1.5X1.5LG6 G1.5X2LG6 G1.5X3LG6 G1.5X4LG6 G2X1LG6 G2X1.5LG6 G2X2LG6 G2X3LG6 G2X4LG6 G2X5LG6 G2.5X3LG6 G3X1LG6 G3X2LG6 G3X3LG6 G3X4LG6 G3X5LG6 G4X1.5LG6 G4X2LG6 G4X3LG6 G4X4LG6 G4X5LG6 G6X4LG6

Duct Size (W x H)* In. mm .69 x .60 17.5 x 15.2 .69 x 1.06 17.5 x 26.9 .69 x 2.03 17.5 x 51.6 .69 x 4.10 17.5 x 104.1 .93 x .82 23.6 x 20.8 .93 x 1.06 .93 x 1.57 .93 x 2.03 1.26 x 1.12 1.26 x 1.62 1.26 x 2.12 1.26 x 3.12 1.26 x 4.10 1.75 x 1.12 1.75 x 1.62 1.75 x 2.12 1.75 x 3.12 1.75 x 4.10 2.25 x 1.12 2.25 x 1.62 2.25 x 2.12 2.25 x 3.12 2.25 x 4.10 2.25 x 5.10 2.75 x 3.12 3.25 x 1.12 3.25 x 2.12 3.25 x 3.12 3.25 x 4.10 3.25 x 5.10 4.25 x 1.62 4.25 x 2.12 4.25 x 3.12 4.25 x 4.10 4.25 x 5.10 6.25 x 4.15 23.6 x 26.9 23.6 x 39.9 23.6 x 51.7 32.0 x 28.4 32.0 x 41.1 32.0 x 53.8 32.0 x 79.2 32.0 x 104.1 44.5 x 28.4 44.5 x 41.1 44.5 x 53.8 44.5 x 79.2 44.5 x 104.1 57.2 x 28.4 57.2 x 41.1 57.2 x 53.8 57.2 x 79.2 57.2 x 104.1 57.2 x 129.5 69.9 x 79.2 82.6 x 28.4 82.6 x 53.8 82.6 x 79.2 82.6 x 104.1 82.6 x 129.5 108.0 x 41.1 108.0 x 53.8 108.0 x 79.2 108.0 x 104.1 108.0 x 129.5 158.8 x 105.4

Slot Width In. mm .38 9.7 .31 7.9 .31 7.9 .31 7.9 .31 7.9 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .38 .31 .31 .31 .31 .31 .38 .31 .31 .31 .31 .38 .31 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 9.7 7.9 7.9 7.9 7.9 7.9 9.7 7.9 7.9 7.9 7.9 9.7 7.9

Cover Part Number C.5LG6 C.5LG6 C.5LG6 C.5LG6 C.75LG6 C.75LG6 C.75LG6 C.75LG6 C1LG6 C1LG6 C1LG6 C1LG6 C1LG6 C1.5LG6 C1.5LG6 C1.5LG6 C1.5LG6 C1.5LG6 C2LG6 C2LG6 C2LG6 C2LG6 C2LG6 C2LG6 C2.5LG6 C3LG6 C3LG6 C3LG6 C3LG6 C3LG6 C4LG6 C4LG6 C4LG6 C4LG6 C4LG6 C6LG6

Std. Pkg. Qty. 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

Base Cover Ctn. Ctn. Qty. Qty. 120 120 120 120 120 120 60 120 120 120 120 120 120 120 120 120 120 60 120 120 120 120 60 120 120 120 60 60 60 120 120 120 60 60 60 120 60 60 60 60 60 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

E
For .5" duct height: .75" to 2" duct height: 3" to 4" duct height: 5" duct height: E .37" [9.4] .31" [7.9] .31" [7.9] .38" [9.4] F .80" [20.3] .80" [20.3] 1.00" [25.4] 1.33" [33.8]

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

To order cover with protective film add F to part number. 6" cover not available with film.

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

Part number shown for LG (Light Gray). For other color availability see color selection guide, page C1.48. Base and cover sold separately. *H dimension includes duct and cover.

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.9

ELECTRICAL SOLUTIONS
A. System Overview

Features and Benefits PANDUCT Type F Narrow Slot Wiring Duct


Available in 30 sizes from .5" x .5" up to 4" x 5" in a variety of colors.

B1. Cable Ties

B2. Cable Accessories

Double restricted slot design retains wires, eliminating hassle and saving time

Non-slip cover liner prevents cover slide

B3. Stainless Steel Ties

Exclusive PANDUIT smooth rounded edges prevents wiring abrasion

C1. Wiring Duct

Specially formulated lead-free PVC material Flush cover design provides a neat appearance

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

Upper and lower scorelines allows easy fingers and sidewall section removal saving installation time

Narrow finger/slot design closely matches the spacing of high-density components

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

PANDUCT Wire Retainers for Type F Wiring Duct Contain wiring when duct cover is opened. Wire retainers snap easily between duct fingers. See page C1.28.

PANDUCT Divider Wall Create separate wiring channels within the wiring duct base. Available in solid or slotted wall styles. See page C1.26.

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

PANDUCT Type C Cover with Protective Film Reduces scrap and labor costs by protecting the surface during storage, handling, and installation. See page C1.11.

PANDUCT Nylon Rivets Fast, lowest cost mounting method. See page C1.34.

PANDUCT Installation Tools Wide selection of hand tools for cutting and installing wiring duct. See page C1.34.

C1.10

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANDUCT Type F Narrow Slot Wiring Duct
Narrow slot/finger design provides more slots to fit the spacing of high-density terminal blocks and other hardware Material: Lead-free PVC UL recognized continuous use temperature: 122F (50C) UL 94 flammability rating of V-0 Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material Provided with mounting holes Base and cover length is 6 feet
A. System Overview

B1. Cable Ties

B2. Cable Accessories

Base Part Number F.5X.5LG6 F.5X1LG6 F.75X.75LG6 F.75X1.5LG6 F1X1LG6 F1X1.5LG6 F1X2LG6 F1X3LG6 F1X4LG6 F1.5X1LG6 F1.5X1.5LG6 F1.5X2LG6 F1.5X3LG6 F1.5X4LG6 F2X1LG6 F2X1.5LG6 F2X2LG6 F2X3LG6 F2X4LG6 F2X5LG6 F2.5X3LG6 F3X1LG6 F3X2LG6 F3X3LG6 F3X4LG6 F3X5LG6 F4X2LG6 F4X3LG6 F4X4LG6 F4X5LG6

Duct Size (W x H)* In. mm .69 x .60 17.5 x 15.2 .69 x 1.06 17.5 x 26.9 .93 x .82 23.6 x 20.9 .93 x 1.57 23.6 x 39.9 1.26 x 1.13 32.0 x 28.7 1.26 x 1.62 32.0 x 41.1 1.26 x 2.12 32.0 x 53.8 1.26 x 3.12 32.0 x 79.2 1.26 x 4.10 32.0 x 104.1 1.75 1.75 1.75 1.75 1.75 2.25 2.25 2.25 2.25 2.25 2.25 2.75 3.25 3.25 3.25 3.25 3.25 4.25 4.25 4.25 4.25 x x x x x x x x x x x x x x x x x x x x x 1.12 1.62 2.12 3.12 4.10 1.12 1.62 2.12 3.12 4.10 5.10 3.12 1.12 2.12 3.12 4.10 5.10 2.12 3.12 4.10 5.10 44.5 x 28.4 44.5 x 41.1 44.5 x 53.8 44.5 x 79.2 44.5 x 104.1 57.2 x 28.4 57.2 x 41.1 57.2 x 53.8 57.2 x 79.2 57.2 x 104.1 57.2 x 129.5 69.9 x 79.2 82.6 x 28.4 82.6 x 53.8 82.6 x 79.2 82.6 x 104.1 82.6 x 129.5 108.0 x 53.8 108.0 x 79.2 108.0 x 104.1 108.0 x 129.5

Slot Width In. mm .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0

Std. Base Cover Cover Pkg. Ctn. Ctn. Part Number Qty. Qty. Qty. C.5LG6 6 120 120 C.5LG6 6 120 120 C.75LG6 6 120 120 C.75LG6 6 120 120 C1LG6 6 120 120 C1LG6 6 120 120 C1LG6 6 120 120 C1LG6 6 120 120 C1LG6 6 60 120 C1.5LG6 C1.5LG6 C1.5LG6 C1.5LG6 C1.5LG6 C2LG6 C2LG6 C2LG6 C2LG6 C2LG6 C2LG6 C2.5LG6 C3LG6 C3LG6 C3LG6 C3LG6 C3LG6 C4LG6 C4LG6 C4LG6 C4LG6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 120 120 120 120 60 120 120 120 60 60 60 120 120 120 60 60 60 60 60 60 60 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

.50 TYP [12.7]

D1. Terminals

.20 TYP [5.0]


Multiple slot restrictors present with 2" and greater duct wall height.

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

To order cover with protective film add F to part number. 6" cover not available with film.

Part number shown for LG (Light Gray). For other color availability see color selection guide, page C1.48. Base and cover sold separately. *H dimension includes duct and cover.

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.11

ELECTRICAL SOLUTIONS
A. System Overview

Features and Benefits PANDUCT Flush Cover Type D Round Hole Wiring Duct
Available in sixteen sizes from 1" x 2" up to 4" x 4" in a variety of colors.

B1. Cable Ties

B2. Cable Accessories

Round hole design retains and supports wire at variable heights to enhance wire management Exclusive PANDUIT smooth rounded edges prevents wiring abrasion

Non-slip cover liner prevents cover slide

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

Specially formulated lead-free PVC material

C3. Abrasion Protection

Flush cover design provides a neat and finished appearance Base scoreline allows easy removal of sidewall section at t-junctions and right angles saving installation time

C4. Cable Management

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

PANDUCT Wire Retainers for Type D Wiring Duct Contain wiring when duct cover is opened. Wire retainers mount onto walls with pressure sensitive adhesive. See page C1.28.

PANDUCT Divider Wall Create separate wiring channels within the wiring duct base. Available in solid or slotted wall styles. See page C1.26.

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

PANDUCT Type C Cover with Protective Film Reduces scrap and labor costs by protecting the surface during storage, handling, and installation. See page C1.13.

PANDUCT Nylon Rivets Fast, lowest cost mounting method. See page C1.34.

PANDUCT Installation Tools Wide selection of hand tools for cutting and installing wiring duct. See page C1.34.

C1.12

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANDUCT Flush Cover Type D Round Hole Wiring Duct
Round hole design has multiple rows of holes to retain and support wire at variable heights and positions Material: Lead-free PVC UL recognized continuous use temperature: 122F (50C) UL 94 flammability rating of V-0 Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material Provided with mounting holes Base and cover length is 6 feet
A. System Overview

B1. Cable Ties

B2. Cable Accessories

Base Part Number D1X2LG6 D1X3LG6 D1X4LG6 D1.5X2LG6 D1.5X3LG6 D1.5X4LG6 D2X2LG6 D2X3LG6 D2X4LG6 D2.5X3LG6 D3X2LG6 D3X3LG6 D3X4LG6 D4X2LG6 D4X3LG6 D4X4LG6

Duct Size (W x H)* In. mm 1.26 x 2.12 32.0 x 53.8 1.26 x 3.12 32.0 x 79.2 1.26 x 4.10 32.0 x 104.1 1.75 x 2.12 44.5 x 53.8 1.75 x 3.12 44.5 x 79.2 1.75 x 4.10 44.5 x 104.1 2.25 2.25 2.25 2.75 3.25 3.25 3.25 4.25 4.25 4.25 x x x x x x x x x x 2.12 3.12 4.10 3.12 2.12 3.12 4.10 2.12 3.12 4.10 57.2 x 53.8 57.2 x 79.2 57.2 x 104.1 69.9 x 79.2 82.6 x 53.8 82.6 x 79.2 82.6 x 104.1 108.0 x 53.8 108.0 x 79.2 108.0 x 104.1

Cover Part Number C1LG6 C1LG6 C1LG6 C1.5LG6 C1.5LG6 C1.5LG6 C2LG6 C2LG6 C2LG6 C2.5LG6 C3LG6 C3LG6 C3LG6 C4LG6 C4LG6 C4LG6

Std. Base Cover Pkg. Ctn. Ctn. Qty. Qty. Qty. 6 120 120 6 120 120 6 120 120 6 120 120 6 120 120 6 60 120 6 6 6 6 6 6 6 6 6 6 120 60 60 120 120 60 60 60 60 60 120 120 120 120 120 120 120 120 120 120

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

.67 .06 TYP [16.94 + - 1.5]

+ -

.44 + - .02 [11.2 + - 0.5]

Part number shown for LG (Light Gray). For other color availability see color selection guide, page C1.48. Base and cover sold separately. *H dimension includes duct and cover.

D1. Terminals

H For 2" duct height = 3 rows of holes 3" duct height = 4 rows of holes 4" duct height = 6 rows of holes

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

To order cover with protective film add F to part number. 6" cover not available with film.

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.13

ELECTRICAL SOLUTIONS
A. System Overview

Features and Benefits PANDUCT Type MC Metric Narrow Slot Wiring Duct
Available in 22 sizes from 25mm x 25mm up to 100mm x 100mm in international gray and white colors.
Non-slip cover liner prevents cover slide

B1. Cable Ties

B2. Cable Accessories

Double restricted slot design retains wires, eliminating hassle and saving time

B3. Stainless Steel Ties

C1. Wiring Duct

Narrow finger/slot design matches the spacing of high-density components

C2. Surface Raceway

C3. Abrasion Protection

Flush cover design provides a neat finished appearance

C4. Cable Management

D1. Terminals

Specially formulated lead-free PVC material

Upper and lower scorelines allow easy fingers and sidewall section removal saving installation time

DIN 43 659 metric mounting hole pattern meets European requirements

D2. Power Connectors

D3. Grounding Connectors

PANDUCT Wire Retainers for Type MC Wiring Duct Contain wiring when duct cover is opened. Wire retainers snap easily between duct fingers. See page C1.28.

PANDUCT Divider Wall Create separate wiring channels within the wiring duct base. Available in solid or slotted wall styles. See page C1.26.

E1. Labeling Systems

E2. Labels

PANDUCT Installation Tools Wide selection of hand tools for cutting and installing wiring duct. See page C1.34.

PANDUCT Nylon Rivets Fast, lowest cost mounting method. See page C1.34.

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

C1.14

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANDUCT Type MC Metric Narrow Slot Wiring Duct
CE compliant and metric sizing for control panels intended for European applications Material: Lead-free PVC UL recognized continuous use temperature: 122F (50C) UL 94 flammability rating of V-0 Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material Provided with DIN 43 659 mounting holes Duct and cover packaged together in 2m lengths
A. System Overview

B1. Cable Ties

Base and Cover Part Number MC25X25IG2 MC25X37IG2 MC25X50IG2 MC25X62IG2 MC25X75IG2
W

Duct Size (W x H)* mm In. 24.6 x 23.6 .97 x .93 24.6 x 35.8 24.6 x 47.8 24.6 x 59.7 24.6 x 72.4 37.1 x 35.8 37.1 x 47.8 37.1 x 59.7 37.1 x 72.4 49.5 x 47.8 49.5 x 72.4 49.5 x 97.8 62.0 x 35.8 62.0 x 59.7 74.7 x 48.0 74.7 x 59.7 74.7 x 72.4 74.7 x 97.8 99.6 x 48.0 99.6 x 59.7 99.6 x 72.4 .97 x 1.41 .97 x 1.88 .97 x 2.35 .97 x 2.85 1.46 x 1.41 1.46 x 1.88 1.46 x 2.35 1.46 x 2.85 1.95 x 1.89 1.95 x 2.85 1.95 x 3.85 2.44 x 1.41 2.44 x 2.35 2.94 x 1.89 2.94 x 2.35 2.94 x 2.85 2.94 x 3.85 3.92 x 1.89 3.92 x 2.35 3.92 x 2.85 3.92 x 3.85

Slot Width In. mm .20 5.0 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 .20 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0

Base and Replacement Cover Cover Replacement Pkg. Std. Cover Qty. Pkg. Part Number (m) Qty. C25IG2 20 20 C25IG2 C25IG2 C25IG2 C25IG2 C37IG2 C37IG2 C37IG2 C37IG2 C50IG2 C50IG2 C50IG2 C62IG2 C62IG2 C75IG2 C75IG2 C75IG2 C75IG2 C100IG2 C100IG2 C100IG2 C100IG2 20 20 20 20 20 20 20 20 20 10 10 20 20 20 20 10 10 10 10 10 10 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

MC37X37IG2 MC37X50IG2 MC37X62IG2

C2. Surface Raceway

MC37X75IG2 MC50X50IG2 MC50X75IG2 MC50X100IG2 MC62X37IG2 MC62X62IG2

C3. Abrasion Protection

C4. Cable Management

.50 TYP [12.7]

MC75X50IG2 MC75X62IG2 MC75X75IG2 MC75X100IG2

D1. Terminals

.20 TYP [5.0]


Multiple slot restrictors present with 62mm and greater duct wall height.

MC100X50IG2 MC100X62IG2 MC100X75IG2

D2. Power Connectors

MC100X100IG2 99.6 x 97.8

D3. Grounding Connectors

Available in IG (International Gray) and WH (White) colors. Base and cover sold together. *"H" dimension includes duct and cover.

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.15

ELECTRICAL SOLUTIONS
A. System Overview

Features and Benefits PANDUCT Type FS Solid Wall Raceway


Available in 27 sizes from .5" x .5" up to 6" x 4" in a variety of colors.

B1. Cable Ties

B2. Cable Accessories

Non-slip cover liner prevents cover slide Specially formulated lead-free PVC material

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

Flush cover design provides a neat and finished appearance

C4. Cable Management

D1. Terminals

Base scoreline allows easy removal of sidewall sections saving installation time

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

PANDUCT Wire Retainers for Type FS Solid Wall Raceway Contain wiring when duct cover is opened. Wire retainers mounts onto walls with pressure sensitive adhesive. See page C1.28.

PANDUCT Divider Wall Create separate wiring channels within the wiring duct base. Available in solid or slotted wall styles. See page C1.26.

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

PANDUCT Type C Cover with Protective Film Reduces scrap and labor costs by protecting the surface during storage, handling, and installation. See page C1.17.

PANDUCT Nylon Rivets Fast, lowest cost mounting method. See page C1.34.

PANDUCT Installation Tools Wide selection of hand tools for cutting and installing wiring duct. See page C1.34.

C1.16

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANDUCT Type FS Solid Wall Raceway
Solid wall design fully encloses cables providing maximum protection and aesthetics Material: Lead-free PVC UL recognized continuous use temperature: 122F (50C) UL 94 flammability rating of V-0 Base and cover length is 6 feet Duct Size (W x H)* In. mm .69 x .60 17.5 x 15.2 .69 x 1.06 17.5 x 26.9 .93 x .82 23.6 x 20.8 1.26 x 1.12 32.0 x 28.4 1.26 x 1.62 32.0 x 41.1 1.26 x 2.12 32.0 x 53.8 1.26 x 3.12 32.0 x 79.2 1.26 x 4.10 32.0 x 104.1 1.75 x 1.12 44.5 x 28.4 1.75 x 1.62 44.5 x 41.1 1.75 x 2.12 44.5 x 53.8 1.75 x 3.12 44.5 x 79.2 2.25 x 1.12 57.2 x 28.4 2.25 x 1.62 57.2 x 41.1 2.25 x 2.12 57.2 x 53.8 2.25 x 3.12 57.2 x 79.2 2.25 x 4.10 57.2 x 104.1 3.25 x 1.12 82.6 x 28.4 3.25 x 2.12 82.6 x 53.8 3.25 x 3.12 82.6 x 79.2 3.25 x 4.10 82.6 x 104.1 3.25 x 5.10 82.6 x 129.5 4.25 x 2.12 108.0 x 53.8 4.25 x 3.12 108.0 x 79.2 4.25 x 4.10 108.0 x 104.1 4.25 x 5.10 108.0 x 129.5 6.25 x 4.15 158.8 x 105.4 Cover Part Number C.5LG6 C.5LG6 C.75LG6 C1LG6 C1LG6 C1LG6 C1LG6 C1LG6 C1.5LG6 C1.5LG6 C1.5LG6 C1.5LG6 C2LG6 C2LG6 C2LG6 C2LG6 C2LG6 C3LG6 C3LG6 C3LG6 C3LG6 C3LG6 C4LG6 C4LG6 C4LG6 C4LG6 C6LG6 Std. Pkg. Qty. 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Base Cover Ctn. Ctn. Qty. Qty. 120 120 120 120 120 120 120 120 120 120 120 120 120 120 60 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 60 120 60 120 120 120 120 120 60 120 60 120 60 120 60 120 60 120 60 120 60 120 60 120
A. System Overview

B1. Cable Ties

> >

> >

W
> >

> > > > > > > > > >

> > > > >

Base Part Number FS.5X.5LG6NM FS.5X1LG6NM FS.75X.75LG6NM FS1X1LG6NM FS1X1.5LG6NM FS1X2LG6NM FS1X3LG6NM FS1X4LG6NM FS1.5X1LG6NM FS1.5X1.5LG6NM FS1.5X2LG6NM FS1.5X3LG6NM FS2X1LG6NM FS2X1.5LG6NM FS2X2LG6NM FS2X3LG6NM FS2X4LG6NM FS3X1LG6NM FS3X2LG6NM FS3X3LG6NM FS3X4LG6NM FS3X5LG6NM FS4X2LG6NM FS4X3LG6NM FS4X4LG6NM FS4X5LG6NM FS6X4LG6NM

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

D2. Power Connectors

>Indicates parts available with mounting holes. Remove NM from part number. Part Number shown for LG (Light Gray). For other color availability see Color Selection Guide, page C1.48. Base and cover sold separately. *H dimension includes duct and cover.

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

To order cover with protective film add F to part number. 6'' cover not available with film.

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.17

ELECTRICAL SOLUTIONS
A. System Overview

Wiring Duct for Special Environments


Type NNC Halogen-Free Metric Wiring Duct

B1. Cable Ties

B2. Cable Accessories

B3. Stainless Steel Ties

Halogen-free material is nontoxic, lead-free, environmentally safe and will not release toxic or corrosive gases that could endanger public safety or damage sensitive electronic equipment UL 94V-0

C1. Wiring Duct

C2. Surface Raceway

Type NE NORYL* Halogen-Free Wiring Duct

C3. Abrasion Protection

C4. Cable Management

Halogen-free material is non-toxic, lead-free, environmentally safe and will not release toxic or corrosive gases that could endanger public safety or damage sensitive electronic equipment UL 94V-1

D1. Terminals

D2. Power Connectors

Type TMC Low Smoke/Low Toxicity Wiring Duct


Low smoke/low toxicity material emits a low level of toxic fumes and low smoke emissions when burned Performs to global mass transit rail standards: U.S. Federal Rail Administration Guidelines and NFPA 130 requirements

D3. Grounding Connectors

E1. Labeling Systems

French AFNOR NFF 16 101, 16 102 (I1, F1 classification at 2.1mm thickness) German DIN 5510-2 (S4, SR2, ST2 classification) UNIFER Italian Railway Flammability standard EN UNI11925-2 UL 94V-0

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
The material does not emit a high volume of toxic gases when burned per Boeing and Airbus test methods.

The material is self-extinguishing and has excellent flame retardancy UL 94V-0.

The material does not release dense smoke when burned per ASTM E662 test method.

*NORYL is a registered trademark of General Electric Company.

C1.18

ELECTRICAL SOLUTIONS
A. System Overview

Environment/Material Specifications

Typical Applications

pages C1.20 C1.21

B1. Cable Ties

Semiconductor Manufacturing Ship Building Nuclear Power Plants Oil Platforms

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

Environment/Material Specifications

Typical Applications

page C1.24

C2. Surface Raceway

Semiconductor Manufacturing Ship Building Nuclear Power Plants Oil Platforms

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

Environment/Material Specifications

Typical Applications

pages C1.22 C1.23

D2. Power Connectors

Passenger Rail Cars; Rail Stations Other Transportation Vehicles

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

The material contains no fluorine, bromide, or chlorine and will not emit any corrosive or toxic gases when burned per IEC 60754-2 test method.

Material is rated for a continuous use temperature above 75C (167F).

C1.19

ELECTRICAL SOLUTIONS
A. System Overview

Features and Benefits PANDUCT Type NNC Halogen-Free Metric Wiring Duct
Available in fourteen sizes from 25mm x 25mm up to 100mm x 100mm in light gray and white.

B1. Cable Ties

B2. Cable Accessories

DIN 43 659 metric mounting hole pattern meets European requirements

Non-slip cover liner prevents cover slide

B3. Stainless Steel Ties

C1. Wiring Duct

Halogen-free modified PPO material is environmentally safe and will not release corrosive or toxic gases Flush cover design provides a neat and finished appearance Wide finger/slot design provides greater rigidity and allows use with a wide range of wire and bundle sizes

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

Upper and lower scorelines allows easy finger and sidewall section removal, saving installation time

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

PANDUCT Type NNC Halogen-Free Solid Divider Wall Create separate wiring channels within the wiring duct base. See page C1.21.

PANDUCT Nylon Rivets Fast, lowest cost mounting method. See page C1.34.

E1. Labeling Systems

E2. Labels

PANDUCT Installation Tools Wide selection of hand tools for cutting and installing wiring duct. See page C1.34.

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

C1.20

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANDUCT Type NNC Halogen-Free Metric Wiring Duct
Material: Halogen-free modified PPO material as verified with IEC 60754-2 test method (test on gases evolved during combustion of electric cables) UL recognized continuous use temperature: 203F (95C) UL 94 flammability rating of V-0 Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material Provided with DIN 43 659 mounting holes Metric sizing and finger progression Duct and cover packaged together in 2m lengths
A. System Overview

B1. Cable Ties

B2. Cable Accessories

B3. Stainless Steel Ties

.98 TYP [25.0]

Base and Cover Part Number NNC25X25LG2 NNC25X37LG2 NNC25X50LG2 NNC25X75LG2 NNC37X37LG2 NNC37X50LG2 NNC37X75LG2 NNC50X50LG2 NNC50X75LG2 NNC50X100LG2 NNC75X75LG2 NNC100X50LG2 NNC100X75LG2 NNC100X100LG2

Duct Size (W x H)* mm 24.6 x 23.6 24.6 x 35.8 24.6 x 47.8 24.6 x 72.4 37.1 x 35.8 37.1 x 47.8 37.1 x 72.4 49.5 x 47.8 49.5 x 72.4 49.5 x 97.8 74.7 x 72.4 99.6 x 47.8 99.6 x 72.4 99.6 x 97.8 In. .97 x .93 .97 x 1.41 .97 x 1.88 .97 x 2.85 1.46 x 1.41 1.46 x 1.88 1.46 x 2.85 1.95 x 1.88 1.95 x 2.85 1.95 x 3.85 2.94 x 2.85 3.92 x 1.88 3.92 x 2.85 3.92 x 3.85

Slot Width In. .39 .39 .39 .39 .39 .39 .39 .39 .39 .39 .39 .39 .39 .39 mm 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0

Base and Replacement Cover Cover Replacement Ctn. Ctn. Cover Qty. Qty. Part Number (m) (m) NC25LG2 20 20 NC25LG2 20 20 NC25LG2 20 20 NC25LG2 20 20 NC37LG2 20 20 NC37LG2 20 20 NC37LG2 20 20 NC50LG2 20 20 NC50LG2 10 20 NC50LG2 10 20 NC75LG2 10 20 NC100LG2 10 20 NC100LG2 10 20 NC100LG2 10 20

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

.39 TYP [10.0]


Multiple slot restrictors present with 75mm and greater duct wall height.

Available in LG (Light Gray) and WH (White). Do not allow cutting, tapping, or cleaning fluids that contain hydrocarbons to come in contact with type NNC wiring duct as it will cause stress cracking. See page C1.47 for a list of chemicals to avoid. *H dimension includes duct and cover.

D2. Power Connectors

D3. Grounding Connectors

PANDUCT Type NNC Divider Wall


NNC solid divider wall can be mounted inside NNC and NE wiring duct to create multiple channels Material: Halogen-free modified PPO Simply install the divider wall base when mounting the duct and snap the divider wall onto mounting base, DB-C

E1. Labeling Systems

Part Number NNC50DWH2 NNC75DWH2

Length (m) 2 2

For Nominal Duct Height (mm) 50 75

Std. Pkg. Qty. 2 2

Std. Ctn. Qty. (m) 40 40

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

Available in WH (White) color only. Note: Must be used with mounting base, DB-C (see page C1.26) which is sold separately. Install mounting bases to the duct channel, locate within 2" of each divider wall end and at least 12" along the length.

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.21

ELECTRICAL SOLUTIONS
A. System Overview

Features and Benefits PANDUCT Type TMC Low Smoke/Low Toxicity Wiring Duct
Available in seven sizes from 25mm x 37mm up to 100mm x 75mm in Beige color.

B1. Cable Ties

B2. Cable Accessories

Double restricted slot design retains wires, eliminating hassle and saving time

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

Non-slip cover liner prevents cover slide Narrow finger/slot design closely matches the spacing of high-density components Low smoke, low toxicity, and low flammability material meets Federal Rail Administration guidelines DIN 43 659 metric mounting hole pattern meets European requirements Upper and lower scorelines allows easy fingers and sidewall section removal saving installation time

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

PANDUCT Wire Retainers for Type TMC Wiring Duct Contain wiring when duct cover is opened. Wire retainers snap easily between duct fingers. See page C1.28.

PANDUCT Type TMC Low Smoke/ Low Toxicity Solid Divider Wall Create separate wiring channels within the wiring duct base. See page C1.23.

E1. Labeling Systems

E2. Labels

PANDUCT Installation Tools Wide selection of hand tools for cutting and installing wiring duct. See page C1.34.

PANDUCT Nylon Rivets Fast, lowest cost mounting method. See page C1.34.

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

C1.22

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANDUCT Type TMC Low Smoke/Low Toxicity Wiring Duct
Material: low smoke, low toxicity, and low flammability thermoplastic UL recognized continuous use temperature: 176F (80C) UL 94 flammability rating of V-0 Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material Provided with DIN 43 659 mounting holes Metric sizing and finger progression Duct and cover packaged together in 2m lengths
A. System Overview

B1. Cable Ties

B2. Cable Accessories

Base and Cover Part Number TMC25X37BR2 TMC37X37BR2 TMC50X50BR2 TMC75X50BR2 TMC75X75BR2 TMC100X50BR2 TMC100X75BR2

Duct Size W x H* In. mm .97 x 1.41 24.6 x 35.8 1.46 x 1.41 37.1 x 35.8 1.95 x 1.89 49.5 x 48.0 2.94 x 1.89 74.7 x 48.0 2.94 x 2.88 74.7 x 73.2 3.92 x 1.89 99.6 x 48.0 3.92 x 2.88 99.6 x 73.2

Slot Width In. mm .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 5.0 .20 5.0

Base and Replacement Cover Cover Replacement Ctn. Ctn. Cover Qty. Qty. Part Number (m) (m) TC25BR2 20 20 TC37BR2 20 20 TC50BR2 20 20 TC75BR2 20 20 TC75BR2 10 20 TC100BR2 10 20 TC100BR2 10 20

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

Available in BR (Natural Beige) color only. *H dimension includes duct and cover.

C4. Cable Management

.50 TYP [12.7]

D1. Terminals

.20 TYP [5.0]


Multiple slot restrictors present with 75mm and greater duct wall height.

D2. Power Connectors

D3. Grounding Connectors

PANDUCT Type TMC Low Smoke/Low Toxicity Solid Divider Wall


Wiring duct divider wall can be mounted inside any type of PANDUIT PVC wiring duct to create multiple channels Simply install the divider wall base when mounting the duct and snap the divider wall onto the mounting base All versions snap onto DB-C mounting base Divider wall heights 2 inches and greater have a scoreline feature allowing sections to be removed leaving a smooth edge Meets UL 508/508A insulation material requirement for barrier between conductors UL 94 flammability rating of V-0 Material: Lead-free PVC For Nominal Duct Height (mm) 50 75 Std. Pkg. Qty. 2 2 Std. Ctn. Qty. 20 20
E1. Labeling Systems

E2. Labels

Part Number TMC50DW2 TMC75DW2

Length (m) 2 2

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

Note: Must be used with mounting base, DB-C (see page C1.26) which is sold separately. Install mounting bases to the duct channel, locate within 2" of each divider wall end and at least every 12" along the length.

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.23

ELECTRICAL SOLUTIONS
A. System Overview

PANDUCT Type NE NORYL** Halogen-Free Wiring Duct


Material: Halogen-free NORYL** UL recognized continuous use temperature: 203F (95C) UL 94 flammability fating of V-1 Provided with mounting holes Base and cover length is 6 feet

B1. Cable Ties

B2. Cable Accessories

Duct Size W x H*
B3. Stainless Steel Ties

Slot Width In. .38 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .31 .38 .31 .31 .31 .38 mm 9.7 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 9.7 7.9 7.9 7.9 9.7 Cover Part Number NC.5WH6 NC.5WH6 NC1WH6 NC1WH6 NC1WH6 NC1WH6 NC1WH6 NC1.5WH6 NC1.5WH6 NC1.5WH6 NC1.5WH6 NC2WH6 NC2WH6 NC2WH6 NC2WH6 NC3WH6 NC3WH6 NC3WH6 NC3WH6 NC3WH6 NC4WH6 NC4WH6 NC4WH6 NC4WH6

C1. Wiring Duct

Base Part Number NE.5X.5WH6 NE.5X1WH6 NE1X1WH6 NE1X1.5WH6 NE1X2WH6


W

In. .63 x .56 .63 x 1.06 1.14 x 1.06 1.14 x 1.62 1.14 x 2.06 1.14 1.14 1.64 1.64 1.64 1.64 2.14 2.14 2.14 2.14 3.14 3.14 3.14 3.14 3.14 4.14 4.14 4.14 4.14 x x x x x x x x x x x x x x x x x x x 3.06 4.06 1.62 2.06 3.06 4.06 1.06 2.06 3.06 4.06 1.06 2.06 3.06 4.06 5.06 2.06 3.06 4.06 5.06

mm 16.0 x 14.2 16.0 x 26.9 29.0 x 26.9 29.0 x 41.1 29.0 x 52.3 29.0 x 77.7 29.0 x 103.1 41.7 x 41.1 41.7 x 52.3 41.7 x 77.7 41.7 x 103.1 54.4 x 26.9 54.4 x 52.3 54.4 x 77.7 54.4 x 103.1 79.8 x 26.9 79.8 x 52.3 79.8 x 77.7 79.8 x 103.1 79.8 x 128.5 105.2 x 52.3 105.2 x 77.7 105.2 x 103.1 105.2 x 128.5

Std. Pkg. Qty. 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

Base Cover Ctn. Ctn. Qty. Qty. 120 120 120 120 120 120 120 120 120 120 120 60 120 120 120 60 120 120 60 60 120 120 60 60 60 60 60 60 60 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management


F

D1. Terminals

D2. Power Connectors

E
For .5" duct height: 1" to 2" duct height: 3" to 4" duct height: 5" duct height: E .37" [9.4] .31" [7.9] .31" [7.9] .38" [9.4] F .80" [20.3] .80" [20.3] 1.00" [25.4] 1.33" [33.8]

D3. Grounding Connectors

NE1X3WH6 NE1X4WH6 NE1.5X1.5WH6 NE1.5X2WH6 NE1.5X3WH6 NE1.5X4WH6 NE2X1WH6 NE2X2WH6 NE2X3WH6 NE2X4WH6 NE3X1WH6 NE3X2WH6 NE3X3WH6 NE3X4WH6 NE3X5WH6 NE4X2WH6 NE4X3WH6 NE4X4WH6 NE4X5WH6

E1. Labeling Systems

Available in WH (White) only. Do not allow cutting, tapping, or cleaning fluids that contain hydrocarbons to come in contact with type NE wiring duct as it will cause stress cracking. See page C1.47 for list of chemicals to avoid. Base and cover sold separately. *H dimension includes duct and cover. **NORYL is a registered trademark of General Electric Company.

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

C1.24

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
A. System Overview

WIRING DUCT TOOLS AND ACCESSORIES


PANDUIT offers a selection of PANDUCT Tools and Accessories to aid cutting, modifying, and installing wiring duct.

B1. Cable Ties

B2. Cable Accessories

Some of the features and benefits found in PANDUCT Tools and Accessories include: Wide selection of hand tools for cutting and installing wiring duct Snap-in wire retainers to retain cabling when the cover is removed or during cable installation Divider walls that mount within the duct enabling multiple channels to be created within a duct channel Corner strips hold corners rigid at t-junctions in control panel applications Joining strips to connect two sections of duct and hold the walls rigid Mounting clips provide an alternative method to mount the duct and allow the duct to be more easily removed

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.25

ELECTRICAL SOLUTIONS
A. System Overview

PANDUCT Type FL Flexible Wiring Duct


Material: Flexible Polypropylene UL Recognized continuous use temperature: 149F (65C) UL 94 flammability rating of V-2 Factory applied adhesive tape provided for easy mounting Duct Size (W x H)* Length In. 19.7 19.7 19.7 mm 500 500 500 Std. Pkg. Qty. 112 70 32

B1. Cable Ties

B2. Cable Accessories

B3. Stainless Steel Ties

Part Number FL12X12LG-A FL25X25LG-A FL50X50LG-A

In. .49 x .49 .98 x .98 1.97 x 1.97

mm 12.5 x 12.5 25.0 x 25.0 50.0 x 50.0

Available in LG (RAL 7040 Light Gray) color only. Unit of measure is pieces. *H dimension includes duct and cover.

W
C1. Wiring Duct

.20 TYP [5.0]


H

C2. Surface Raceway

.25 TYP [6.2]

C3. Abrasion Protection

PANDUCT Divider Wall


Wiring duct divider wall can be mounted inside any type of PANDUIT PVC wiring duct to create multiple channels Simply install the divider wall base when mounting the duct and snap the divider wall onto the mounting base All versions snap onto DB-C mounting base Divider wall heights 2 inches and greater have a scoreline feature allowing sections to be removed leaving a smooth edge Meets UL 508/508A insulation material requirement for barrier between conductors UL 94 flammability rating of V-0 Material: Lead-free PVC Std. Pkg. Qty. 100 Std. Pkg. Qty. 6 6 6 6 6 6 6 6 2 2 2 6 6 6 6 6 6 Std. Ctn. Qty. 1000 Std. Ctn. Qty. 120 120 120 120 120 120 120 120 40 40 40 120 120 120 120 120 120

C4. Cable Management

D1. Terminals

Part Number DB-C DB-C Part Number

Used with Anchors

PANDUCT Divider Wall Mounting Base


D2. Power Connectors

PANDUIT NR1 or #8 or #10 screw

For Nominal Duct Height In. mm 1.00 1.50 2.00 3.00 4.00 2.00 3.00 4.00 2.00 3.00 4.00 2.00 3.00 4.00 2.00 3.00 4.00 25 37 50 75 100 50 75 100 50 75 100 50 75 100 50 75 100

Length Ft. m 6 6 6 6 6 6 6 6 6 6 6 6 6 6 2 2 2

Color Light Gray Light Gray Light Gray Light Gray Light Gray White White White International Gray International Gray International Gray Light Gray Light Gray Light Gray White White White

D3. Grounding Connectors

PANDUCT Solid Divider Wall

E1. Labeling Systems

E2. Labels

D*H6 and D*H2

D1H6 D1.5H6 D2H6 D3H6 D4H6 D2HWH6 D3HWH6 D4HWH6 D50H2 D75H2 D100H2 SD2H6 SD3H6 SD4H6 SD2HWH6 SD3HWH6 SD4HWH6

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

PANDUCT Metric Solid Divider Wall

PANDUCT Slotted Divider Wall

SD*H6

Note: Must be used with mounting base, DB-C (see page C1.26) which is sold separately. Install mounting bases to the duct channel, locate within 2" of each divider wall end and at least every 12" along the length.

C1.26

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANDUCT Type NNC Divider Wall
NNC solid divider wall can be mounted inside NNC and NE wiring duct to create multiple channels Material: Halogen-free modified PPO Simply install the divider wall base when mounting the duct and snap the divider wall onto mounting base, DB-C
A. System Overview

B1. Cable Ties

For Nominal Duct Height Part Number NNC50DWH2 NNC75DWH2 In. 2.00 3.00 mm 50 75

Std. Pkg. Qty. 2 2

Std. Ctn. Qty. 40 40

B2. Cable Accessories

Available in WH (White) color only. Note: Must be used with mounting base, DB-C (see page C1.26) which is sold separately. Install mounting bases to the duct channel, locate within 2" of each divider wall end and at least 12" along the length.

B3. Stainless Steel Ties

C1. Wiring Duct

PANDUCT Type TMC Low Smoke/Low Toxicity Solid Divider Wall


Wiring duct divider wall can be mounted inside any type of PANDUIT PVC wiring duct to create multiple channels Simply install the divider wall base when mounting the duct and snap the divider wall onto the mounting base All versions snap onto DB-C mounting base Divider wall heights 2 inches and greater have a scoreline feature allowing sections to be removed leaving a smooth edge Meets UL508/508A insulation material requirement for barrier between conductors UL 94 flammability rating of V-0 Material: Lead-free PVC Std. Pkg. Qty. 2 2 Std. Ctn. Qty. 20 20

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

For Nominal Duct Height Part Number TMC50DW2 TMC75DW2 In. 2 3 mm 50 75

D1. Terminals

Note: Must be used with mounting base, DB-C (see page C1.26) which is sold separately. Install mounting bases to the duct channel, locate within 2" of each divider wall end and at least every 12" along the length.

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.27

ELECTRICAL SOLUTIONS
A. System Overview

PANDUCT Type G and H Wiring Duct Wire Retainers


Insert between fingers of type G and H to contain wiring when cover is removed Adjustable height Material: ABS Std. Pkg. Qty. 100 100 100 100 100 Std. Ctn. Qty. 1000 1000 1000 1000 1000

B1. Cable Ties

B2. Cable Accessories

B3. Stainless Steel Ties

Part Number WR2-C WR2H-C WR3-C WR4-C WR5-C

For Duct Width In. (mm) 2.00 (50.8) 2.00(50.5) 3.00 (76.2) 4.00 (101.6) Use with: 3 x 5, 4 x 5 or 6 x 4

For Duct Height In. (mm) 2.00 4.00 (50.8 101.6) 2.00 4.00 (50.8 101.6) 2.00 4.00 (50.8 101.6) 2.00 4.00 (50.8 101.6) Use with: 3 x 5, 4 x 5 or 6 x 4

*For 2" width type H hinged cover wiring duct use part number WR2H-C.

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

PANDUCT Solid Wall Raceway Type FS and Type D Wiring Duct Wire Retainer
Mounts onto walls of type FS raceway or type D duct with pressure sensitive adhesive One size fits three different duct widths Full length is used with 2 inch wide duct; for small widths, break off segments at scorelines Material: Lead-free PVC Std. Pkg. Qty. 100 Std. Ctn. Qty. 1000

C4. Cable Management

D1. Terminals

Part Number WRS-A-C10

D2. Power Connectors

For Duct Width In. (mm) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8)

Full length is used with 2" wide duct. For smaller widths, break off segments at scorelines.

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

C1.28

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANDUCT Type F, HN, MC and TMC Duct Wire Retainers/Labeling Device
Used to contain wiring when cover is removed and can also be used as a labeling device FWR-C works with all type F and HN duct sizes FMWR-C works with all type MC and TMC sizes Material: Lead-free PVC
A. System Overview

B1. Cable Ties

Part Number FWR-C FMWR-C

Material Rigid PVC Rigid PVC

For Duct Width In. mm 1.50 4.00 37.0 76.2 1.46 3.94 37 100

Std. Pkg. Qty. 100 100

Std. Ctn. Qty. 1000 1000

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway


Labeling Inside Duct Snaps onto duct fingers. Full length for use with 4" wide duct. For smaller widths, break off segments at scorelines. Labeling Outside Duct Break off the last segment from wire retainer below (1.5'' mark) and snap onto the back of the remaining segment. Install label and mount between fingers facing outward.

C3. Abrasion Protection

PANDUCT Duct Corner Strips with 1 Inch Bend Radius Control


Create a strong rigid corner at wiring duct junctions Provide bend radius protection for cabling as required in NFPA 79-2007 section 13.1.5.9 and TIA/EIA-568-B and 569-A Available in five pre-cut sizes and 6-foot lengths that can be cut-to-size to meet any size requirement Easy to install two-piece design Compatible with all styles of PANDUIT wiring duct UL 94 flammability rating of V-0 Material: Lead-free PVC

C4. Cable Management

D1. Terminals

D2. Power Connectors

Part Number CSC1LG6 CSC1WH6

Part Description

For Duct Height In. mm All sizes (Cut to duct height) 1.00 1.50 All sizes (Cut to duct height) 25.4 38.1

Color Light Gray White

Std. Std. Pkg. Ctn. Qty. Qty. 6 6 120 120

6' Lengths for use with all Types of PVC Wiring Duct
Cut-to-size 6' corner strip with a 1" bend radius.

D3. Grounding Connectors

E1. Labeling Systems

Pre-Cut Pieces for use with all Types of PVC Wiring Duct
CSPC1LG-Q CSPC1.5LG-Q 1" bend radius corner strip pre-cut for 1" wall height. 1" bend radius corner strip pre-cut for 1.5" wall height (2.0" type H duct). 1" bend radius corner strip pre-cut for 2" wall height. 1" bend radius corner strip pre-cut for 3" wall height. 1" bend radius corner strip pre-cut for 4" wall height (4.0" type H duct). Light Gray Light Gray Light Gray Light Gray Light Gray 25 25 250 250
E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

E2. Labels

CSPC2LG-Q CSPC3LG-Q CSPC4LG-Q

2.00 3.00 4.00

50.8 76.2 101.6

25 25 25

250 250 250

CSPC available in Light Gray color only. Order number of feet required, in multiples of 6' or Standard Package Quantity for pieces offered in 6' lengths.

C1.29

ELECTRICAL SOLUTIONS
A. System Overview

PANDUCT Duct Corner Strips


Slide onto duct at corner or t-junctions for smooth, round corners Available in five pre-cut sizes and 6-foot lengths that can be cut to meet any size requirement Easy to install one-piece design Compatible with all styles of PANDUIT wiring duct UL 94 flammability rating of V-0 Material: Lead-free PVC

B1. Cable Ties

B2. Cable Accessories

B3. Stainless Steel Ties

Part Number CS1LG6 CS1LG6 CS1WH6

Part Description 6' length is cut by user to fit duct height. 6' length is cut by user to fit duct height.

Std. Std. For Nominal Duct Height Pkg. Ctn. In. mm Color Qty. Qty. Cut-to-size Cut-to-size Cut-to-size Cut-to-size Light Gray White 6 6 120 120

6' Lengths for use with all Types of PVC Wiring Duct

C1. Wiring Duct

Pre-Cut Pieces for use with all Types of PVC Wiring Duct*
CSP1LG-Q 1.00 Pre-cut pieces. 1.50 2.00 3.00 4.00 25.4 38.1 50.8 76.2 101.6 Light Gray 25 25 25 25 25 250 250 250 250 250 CSP1.5LG-Q CSP2LG-Q CSP3LG-Q CSP4LG-Q CSP*LG-Q

C2. Surface Raceway

C3. Abrasion Protection

*Available in LG (Light Gray) only.

C4. Cable Management

D1. Terminals

PANDUCT Duct Joining Strips


D2. Power Connectors

Slide onto duct to join sections together Available in 6-foot lengths that can be cut to meet any size requirement Easy to install one-piece design

Compatible with all styles of PANDUIT wiring duct UL 94 flammability rating of V-0 Material: Lead-free PVC

D3. Grounding Connectors

Part Number
E1. Labeling Systems

Part Description 6' length is cut by user to fit duct height.

For Duct Height In. mm Cut-to-size Cut-to-size

Color Light Gray White

Std. Pkg. Qty. 6

Std. Ctn. Qty. 120

6' Lengths for use with all Types of PVC Wiring Duct
DJS1**6 DJS1LG6 DJS1WH6

E2. Labels

To cut product to proper length subtract 1/2'' from the duct wall height (example: for G2X2LG6, cut DJS1**6 to 1 1/2'' length).

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

C1.30

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANDUCT Snap-Clip Mounting Brackets
Duct easily snaps into bracket No mounting holes required in duct Ensures no metal is inside the duct Snap-clip spacing is not critical Simplifies fabrication drawings and panel layout Material: Spring steel Std. Std. Pkg. Ctn. Qty. Qty. 100 100 100 100 100 1000 1000 1000 1000 1000
A. System Overview

B1. Cable Ties

Part Number S1F-C S1.5F-C S2F-C S3F-C S4F-C SNS25F-C SNS37F-C SNS50F-C SNS62F-C SNS75F-C

Screw Required #8-32 #8-32 #8-32 #8-32 #8-32 x x x x x 1/4 1/4 1/4 1/4 1/4 (Provided) (Provided) (Provided) (Provided) (Provided)

For Duct Width In. mm 1.00 1.50 2.00 3.00 4.00 1.00 1.50 2.00 2.50 3.00 25.4 38.1 50.8 76.2 101.6 25 37 50 62 75

B2. Cable Accessories

Snap-Clip Mounting Brackets for use with Types G, F, FS and D Wiring Duct
B3. Stainless Steel Ties

Snap-Clip Mounting Brackets for use with Types MC, NNC, and TMC Wiring Duct
#8-32 x 1/4 (User Supplied) #8-32 #8-32 #8-32 #8-32 x x x x 1/4 1/4 1/4 1/4 (User (User (User (User Supplied) Supplied) Supplied) Supplied) 100 1000 100 100 100 100 1000 1000 1000 1000

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

PANDUCT Snap-Clip Mounting Bracket Type NE Wiring Duct


Duct easily snaps into bracket Ensures no metal is inside the duct Snap-clip spacing is not critical Simplifies fabrication drawings and panel layout Material: Spring steel
D1. Terminals

Part Number SNS.5-C SNS.75-C SNS1-C SNS1.5-C SNS2-C SNS3-C

Screw Required #6-32 x 1/4 (User Supplied) #6-32 x 1/4 (User Supplied) #8-32 x 1/4 (User Supplied) #8-32 x 1/4 (User Supplied) #8-32 x 1/4 (User Supplied) #8-32 x 1/4 (User Supplied)

For Duct Width In. mm .50 12.7 .75 19.1 1.00 25.4 1.50 38.1 2.00 50.8 3.00 76.2

Std. Pkg. Qty. 100 100 100 100 100 100

Std. Ctn. Qty. 1000 1000 1000 1000 1000 1000

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.31

ELECTRICAL SOLUTIONS
A. System Overview

Adhesive Tape for Wiring Duct


Recommended installation temperature is 70F (21C) UL Recognized service temperature is 32F (0C) to 140F (60C) Optimum recommended dwell time for acrylic adhesive is 8 hours Recommended tape load is 1/2 lb. per square inch of tape area

B1. Cable Ties

B2. Cable Accessories

Duct Size WxH .5 x .5 thru 1.5 x 4 2 x 1 thru 3 x 3 3 x 4 thru 3 x 5 4 x 1.5 thru 4 x 3 4 x 4 thru 6 x 4

B3. Stainless Steel Ties

C1. Wiring Duct

Tape Part Number P32W2A2-50-7 P32W2A2-50-72 P32W2A2-50-7 P32W2A2-50-72 P32W2A2-75-7 P32W2A2-75-72 P32W2A2-50-7 P32W2A2-75-72 P32W2A2-75-7 P32W2A2-75-72

Roll Length Yds. 7.0 72.0 7.0 72.0 7.0 72.0 7.0 72.0 7.0 72.0 m 6.4 65.5 6.4 65.5 6.4 65.5 6.4 65.5 6.4 65.5

Std. Pkg. Qty. 1 1 1 1 1 1 1 1 1 1

Std. Ctn. Qty. 100 9 100 9 60 7 100 9 60 7

C2. Surface Raceway

C3. Abrasion Protection

Specifications for Factory Applied Tape


Tape Duct Size WxH .5 x .5 through 1.5 x 4 2 x 1 through 3 x 3 3 x 4 through 3 x 5 4 x 1.5 through 4 x 3 4 x 4 through 6 x 4 Rows of Tape 1 2 2 2 2 Width In. .50 .50 .75 .50 .75 mm 12.7 12.7 19.1 12.7 19.1 Thickness In. mm .03 .8 .03 .8 .03 .8 .03 .8 .03 .8

C4. Cable Management

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

C1.32

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
Adhesive Tape Guide
Selection of wiring duct part numbers available with factory applied adhesive tape.
A. System Overview

B1. Cable Ties

B2. Cable Accessories

G Duct Light Gray G.5X.5LG6-A G.5X1LG6-A G.75X.75LG6-A G.75X1LG6-A G.75X1.5LG6-A G.75X2LG6-A G1X1LG6-A G1X1.5LG6-A G1X2LG6-A G1X3LG6-A G1X4LG6-A G1.5X1LG6-A G1.5X1.5LG6-A G1.5X2LG6-A G1.5X3LG6-A G1.5X4LG6-A G2X1LG6-A G2X1.5LG6-A G2X2LG6-A G2X3LG6-A G2X4LG6-A G2X5LG6-A G2.5X3LG6-A G3X1LG6-A G3X2LG6-A G3X3LG6-A G3X4LG6-A G3X5LG6-A G4X1.5LG6-A G4X2LG6-A G4X3LG6-A G4X4LG6-A G4X5LG6-A

G Duct White G.5X.5WH6-A G.5X1WH6-A G.75X1WH6-A G.75X1.5WH6-A G.75X2WH6-A G1X1WH6-A G1X1.5WH6-A G1X2WH6-A G1X3WH6-A G1X4WH6-A G1.5X1WH6-A G1.5X1.5WH-A G1.5X2WH6-A G1.5X3WH6-A G1.5X4WH6-A G2X1WH6-A G2X1.5WH6-A G2X2WH6-A G2X3WH6-A G2X4WH6-A G2X5WH6-A G2.5X3WH6-A G3X1WH6-A G3X2WH6-A G3X3WH6-A G3X4WH6-A G3X5WH6-A G4X1.5WH6-A G4X2WH6-A G4X3WH6-A G4X4WH6-A G4X5WH6-A

G Duct Black G1X3BL6-A G2X2BL6-A G2X4BL6-A G3X3BL6-A G4X4BL6-A

F Duct Light Gray F.5X.5LG6-A F.5X1LG6-A F.75X.75LG6-A F.75X1.5LG6-A F1X1LG6-A F1X1.5LG6-A F1X2LG6-A F1X3LG6-A F1X4LG6-A F1.5X1LG6-A F1.5X1.5LG6-A F1.5X2LG6-A F1.5X3LG6-A F1.5X4LG6-A F2X1LG6-A F2X1.5LG6-A F2X2LG6-A F2X3LG6-A F2X4LG6-A F2X5LG6-A F3X1LG6-A F3X2LG6-A F3X3LG6-A F3X4LG6-A F3X5LG6-A F4X2LG6-A F4X3LG6-A F4X4LG6-A F4X5LG6-A

NE Duct White NE1X2WH6-A NE1.5X2WH6-A NE2X2WH6-A NE4X2WH6-A NE4X3WH6-A NE4X4WH6-A

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

All three sizes of flexible duct come provided with adhesive: FL12X12LG-A, FL25X25LG-A, FL50X50LG-A.

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.33

ELECTRICAL SOLUTIONS
A. System Overview

PANDUCT Installation Tools


PBDCT and DCT easily cut PANDUCT Wiring Duct and Cover DNT-100 notches duct sidewalls to bottom scoreline for tees and corner junctions TNR installs or removes PANDUIT Nylon Rivets, NR1-C and NR1-M, quickly and easily DFCT easily removes duct fingers in tight places Std. Pkg. Qty

B1. Cable Ties

B2. Cable Accessories

Part Number

Part Description

Duct Cutting Tool


B3. Stainless Steel Ties

PBDCT

PANDUIT bench-mount duct cutting tool. Cuts slotted wiring ducts and wiring duct covers with up to 6" width and up to 5" height. Full 78.74" (2m) measuring scale. Includes safety guarding.
Hand-held duct cutting tool.

DCT
C1. Wiring Duct

PBDCT

Replacement Blade Kit (Includes blade and nylon insert)


DCT-BLD Replacement blade kit with blade and nylon insert. 1

C2. Surface Raceway

Replacement Nylon Insert


DCT-RI DCT DFCT Replacement nylon insert. 5

C3. Abrasion Protection

Duct Finger Cutting Tool (For use with all wide slotted duct types)
DFCT Hand-held duct finger cutting tool. 1

Duct Notching Tool (For use with all slotted duct types)
DNT-100 Hand-held sidewall notching tool. 1

C4. Cable Management

Nylon Rivet Installation Tool


DNT-100 TNR TNR Hand-held nylon rivet installation tool. 1

D1. Terminals

Nylon Rivets
NR1-C Nylon rivet for use with TNR rivet tool. Mean pull-off force: PVC 90 lbs., Noryl Duct (Type NE) 70 lbs. Mean shear force: PVC 139 lbs., Noryl Duct (Type NE) 126 lbs. Nylon rivet for use with TNR rivet tool. Mean pull-off force: PVC 90 lbs., Noryl Duct (Type NE) 70 lbs. Mean shear force: PVC 139 lbs., Noryl Duct (Type NE) 126 lbs. 100

D2. Power Connectors

NR1-M NR1

1000

Always use approved safety goggles when using any tools.

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

Total Thickness of Panel and Duct In. mm .158 .187 4.0 4.7 .188 .218 4.8 5.5 .219 .250 5.6 6.4 .251 .281 6.5 7.1

Panel Hole Dia. Needed In. mm .187 4.7 .193 4.9 .203 5.2 .213 5.4

ANSI Standard Drill Bit #15 #11 #7 #4

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

C1.34

Order number of pieces required, in multiples of Standard Package Quantity.

Prime items appear in BOLD.

ELECTRICAL SOLUTIONS
PANDUCT PANELMAX Corner Wiring Duct Dimensions
Dimensions are shown for reference only. Contact PANDUIT customer service at 800-777-3300 for specific dimensional needs.
B1. Cable Ties
Dimensions Inches (mm) Size CWD3 CWD4 A 4.98 (126.6) 5.94 (150.9) C 2.25 (57.2) 2.25 (57.2) D 2.83 (71.8) 3.84 (97.5) G 3.10 (79.1) 4.10 (104.1) H 3.57 (90.7) 4.58 (115.7) K 3.95 (100.4) 4.89 (124.3) T .10 (2.4) .11 (2.7) W 4.40 (111.8) 5.33 (135.3) Z 5.16 (131.0) 6.54 (166.0)

A. System Overview

B2. Cable Accessories

C T A

.50 TYP [12.7]

2.00 [50.8]

B3. Stainless Steel Ties

D Z G H A W A .20 TYP [5.0] View A A .20 TYP [5.0] 2.00 TYP [50.8] .50 TYP [12.7]

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.35

ELECTRICAL SOLUTIONS
A. System Overview

PANDUCT Type G and D Wiring Duct Dimensions


Dimensions are shown for reference only. Contact PANDUIT customer service at 800-777-3300 for specific dimensional needs.
Duct Size (W x H) A B .5 x .5 .69 .60 (12.7) (12.7) (17.5) (15.2) .5 x 1 .69 1.06 (12.7) (25.4) (17.5) (26.9) .5 x 2 .69 2.03 (12.7) (50.8) (17.5) (51.6) .5 x 4 .69 4.10 (12.7) (101.6) (17.5) (104.1) .75 x .75 .93 .82 (19.1) (19.1) (23.6) (20.8) .75 x 1 .93 1.06 (19.1) (25.4) (23.6) 26.9 .75 x 1.5 .93 1.57 (19.1) (38.1) (23.6) (39.9) .75 x 2 .93 2.03 (19.1) (50.8) (23.6) (51.6) 1x1 1.26 1.12 (25.4) (25.4) (32.0) (28.4) 1 x 1.5 1.26 1.62 (25.4) (38.1) (32.0) (41.1) 1x2 1.26 2.12 (25.4) (50.8) (32.0) (53.8) 1x3 1.26 3.12 (25.4) (76.2) (32.0) (79.2) 1x4 1.26 4.10 (25.4) (101.6) (32.0) (104.1) 1.5 x 1 1.75 1.12 (38.1) (25.4) (44.5) (28.4) 1.5 x 1.5 1.75 1.62 (38.1) (38.1) (44.5) (41.1) 1.5 x 2 1.75 2.12 (38.1) (50.8) (44.5) (53.8) 1.5 x 3 1.75 3.12 (38.1) (76.2) (44.5) (79.2) 1.5 x 4 1.75 4.10 (38.1) (101.6) (44.5) (104.1) 2x1 2.25 1.12 (50.8) (25.4) (57.2) (28.4) 2 x 1.5 2.25 1.62 (50.8) (38.1) (57.2) (41.1) 2x2 2.25 2.12 (50.8) (50.8) (57.2) (53.8) 2x3 2.25 3.12 (50.8) (76.2) (57.2) (79.2) 2x4 2.25 4.10 (50.8) (101.6) (57.2) (104.1) 2x5 2.25 5.10 (50.8) (127.0) (57.2) (129.5) 2.5 x 3 2.75 3.12 (63.5) (76.2) (69.9) (79.2) 3x1 3.25 1.12 (76.2) (25.4) (82.6) (28.4) 3x2 3.25 2.12 (76.2) (50.8) (82.6) (53.8) 3x3 3.25 3.12 (76.2) (76.2) (82.6) (79.2) 3x4 3.25 4.10 (76.2) (101.6) (82.6) (104.1) 3x5 3.25 5.10 (76.2) (127.0) (82.6) (129.5) 4 x 1.5 4.25 1.62 (101.6) (38.1) (108.0) (41.1) 4x2 4.25 2.12 (101.6) (50.8) (108.0) (53.8) 4x3 4.25 3.12 (101.6) (76.2) (108.0) (79.2) 4x4 4.25 4.10 (101.6) (101.6) (108.0) (104.1) 4x5 4.25 5.10 (101.6) (127.0) (108.0) (129.5) 6x4 6.25 4.15 (152.4) (101.6) (158.8) (105.4) > Available for type G wiring duct only. See page C1.9 and C1.13 for wiring duct C .69 (17.5) .69 (17.5) .69 (17.5) .69 (17.5) .94 (23.9) .94 (23.9) .94 (23.9) .94 (23.9) 1.25 (31.8) 1.25 (31.8) 1.25 (31.8) 1.25 (31.8) 1.25 (31.8) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.75 (69.9) 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 4.25 (108.0) 4.25 (108.0) 4.25 (108.0) 4.25 (108.0) 4.25 (108.0) 6.25 (158.8) Dimensions Inches (mm) D E F .38 .37 .80 (9.5) (9.3) (20.3) .75 .31 .80 (19.1) (7.9) (20.3) 1.63 .31 .80 (41.3) (7.9) (20.3) 2.25 .31 1.00 (57.2) (7.9) (25.4) .56 .31 .80 (14.3) (7.9) (20.3) .75 .31 .80 (19.1) (7.9) (20.3) 1.20 .31 .80 (30.5) (7.9) (20.3) 1.63 .31 .80 (41.3) (7.9) (20.3) .75 .31 .80 (19.1) (7.9) (20.3) 1.20 .31 .80 (30.5) (7.9) (20.3) 1.63 .31 .80 (41.3) (7.9) (20.3) 2.63 .31 1.00 (66.7) (7.9) (25.4) 3.63 .31 1.00 (92.1) (7.9) (25.4) .75 .31 .80 (19.1) (7.9) (20.3) 1.20 .31 .80 (30.5) (7.9) (20.3) 1.63 .31 .80 (41.3) (7.9) (20.3) 2.63 .31 1.00 (66.7) (7.9) (25.4) 3.63 .31 1.00 (92.1) (7.9) (25.4) .75 .31 .80 (19.1) (7.9) (20.3) 1.20 .31 .80 (30.5) (7.9) (20.3) 1.63 .31 .80 (41.3) (7.9) (20.3) 2.63 .31 1.00 (66.7) (7.9) (25.4) 3.63 .31 1.00 (92.1) (7.9) (25.4) 4.63 .38 1.33 (117.5) (9.5) (33.9) 2.63 .31 1.00 (66.7) (7.9) (25.4) .75 .31 .80 (19.1) (7.9) (20.3) 1.63 .31 .80 (41.3) (7.9) (20.3) 2.63 .31 1.00 (66.7) (7.9) (25.4) 3.63 .31 1.00 (92.1) (7.9) (25.4) 4.63 .38 1.33 (117.5) (9.5) (33.9) 1.20 .31 .80 (30.5) (7.9) (20.3) 1.63 .31 0.80 (41.3) (7.9) (20.3) 2.63 .31 1.00 (66.7) (7.9) (25.4) 3.63 .31 1.00 (92.1) (7.9) (25.4) 4.63 .38 1.33 (117.5) (9.5) (33.9) 3.63 .31 1.00 (92.1) (7.9) (25.4) H .50 (12.7) 1.00 (25.4) 2.00 (50.8) 4.00 (101.6) 0.75 (19.1) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 5.00 (127.0) 3.00 (76.2) 1.00 (25.4) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 5.00 (127.0) 1.50 (38.1) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 5.00 (127.0) 4.00 (101.6) K T .05 (1.3) .05 (1.3) .08 (2.0) .10 (2.4) .06 (1.4) .06 (1.4) .07 (1.8) .08 (2.0) .06 (1.4) .07 (1.8) .08 (2.0) .10 (2.4) .11 (2.7) .06 (1.5) .07 (1.8) .08 (2.0) .10 (2.4) .11 (2.7) .06 (1.5) .07 (1.8) .08 (2.0) .10 (2.4) .11 (2.7) .12 (2.9) .10 (2.5) .07 (1.8) .08 (2.0) .10 (2.4) .11 (2.7) .12 (2.9) .07 (1.8) .08 (2.0) .10 (2.5) .11 (2.7) .12 (2.9) .11 (2.8)

B1. Cable Ties


For .5" high duct.
C F

> >

B2. Cable Accessories

> > >

B3. Stainless Steel Ties

For .75", 1", 1.5", 2", 3", 4" and 5" high duct.
C F

> >

> >

C2. Surface Raceway

> Note: A dimension is measured at base. Note: K dimension shown in mounting hole dimensions below.

C3. Abrasion Protection

C4. Cable Management


.44 + - .02 [11.2 + - 0.5]

> >

D1. Terminals

.67 + - .06 TYP [16.94 + - 1.5]

D2. Power Connectors

> >

D3. Grounding Connectors

For 2" duct height = 3 rows of holes 3" duct height = 4 rows of holes 4" duct height = 6 rows of holes

E1. Labeling Systems

Mounting Hole Dimensions For .5", .75", 1", and 1.5" wide duct.
.50 TYP [12.7] .20 TYP [5.0] C L

>

>

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

4.0 [101.6] TYP

2.0 [50.8]

>
For 2.0", 2.5", 3", 4" and 6" wide duct.

>

K K C L

4.0 [101.6] TYP

2.0 [50.8]

> >

.50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .73 (18.4) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4) 1.50 (38.1) 1.50 (38.1) 1.50 (38.1) 1.50 (38.1) 1.50 (38.1) 2.50 (63.5)

color and size availability.

C1.36

ON CENTERLINE

C1. Wiring Duct

ELECTRICAL SOLUTIONS
PANDUCT Type F Wiring Duct and FS Raceway Dimensions

A. System Overview

Dimensions are shown for reference only. Contact PANDUIT customer service at 800-777-3300 for specific dimensional needs.
Duct Size (W x H)
For .5", .75", 1" and 1.5" high duct.
C E

A .69 (17.5) .69 (17.5) .93 (23.6) .93 (23.6) 1.26 (32.0) 1.26 (32.0) 1.26 (32.0) 1.26 (32.0) 1.26 (32.0) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 4.25 (108.0) 4.25 (108.0) 4.25 (108.0) 4.25 (108.0) 4.25 (108.0) 6.25 (158.8)

B .60 (15.2) 1.06 (26.9) .82 (20.8) 1.57 (39.9) 1.12 (28.4) 1.62 (41.1) 2.12 (53.8) 3.12 (79.2) 4.10 (104.1) 1.12 (28.4) 1.62 (41.1) 2.12 (53.8) 3.12 (79.2) 4.10 (104.1) 1.12 (28.4) 1.62 (41.1) 2.12 (53.8) 3.12 (79.2) 4.10 (104.1) 5.10 (129.5) 1.12 (28.4) 2.12 (53.8) 3.12 (79.2) 4.10 (104.1) 5.10 (129.5) 1.62 (41.1) 2.12 (53.8) 3.12 (79.2) 4.10 (104.1) 5.10 (129.5) 4.15 (105.4)

C .69 (17.5) .69 (17.5) .94 (23.9) .94 (23.9) 1.25 (31.8) 1.25 (31.8) 1.25 (31.8) 1.25 (31.8) 1.25 (31.8) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 4.25 (108.0) 4.25 (108.0) 4.25 (108.0) 4.25 (108.0) 4.25 (108.0) 6.25 (158.8)

Dimensions Inches (mm) D E F .38 (9.5) .75 (19.1) .56 (14.3) 1.20 (30.5) .75 (19.1) 1.20 (30.5) 1.63 (41.3) 2.63 (66.7) 3.63 (92.1) .75 (19.1) 1.20 (30.5) 1.63 (41.3) 2.63 (66.7) 3.63 (92.1) .75 (19.1) 1.20 (30.5) 1.63 (41.3) 2.63 (66.7) 3.63 (92.1) 4.63 (117.5) .75 (19.1) 1.63 (41.3) 2.63 (66.7) 3.63 (92.1) 4.63 (117.5) N/A 1.63 (41.3) 2.63 (66.7) 3.63 (92.1) 4.63 (117.5) N/A .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) N/A .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) N/A .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) 50 (12.7) .50 (12.7) N/A .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) N/A

H .50 (12.7) 1.00 (25.4) .75 (19.1) 1.50 (38.1) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 5.00 (127.0) 1.00 (25.4) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 5.00 (127.0) 1.50 (38.1) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 5.00 (127.0) 4.00 (101.6)

T .05 (1.3) .05 (1.3) .06 (1.4) .07 (1.8) .06 (1.4) .07 (1.8) .08 (2.0) .10 (2.4) .11 (2.7) .06 (1.5) .07 (1.8) .08 (2.0) .10 (2.4) .11 (2.7) .06 (1.5) .07 (1.8) .08 (2.0) .10 (2.4) .11 (2.7) .12 (2.9) .07 (1.7) .08 (2.0) .10 (2.4) .11 (2.7) .12 (2.9) .07 (1.8) .08 (2.0) .10 (2.4) .11 (2.7) .12 (2.9) .11 (2.8)

B1. Cable Ties

B T A

ON CENTERLINE

For 2", 3", 4" and 5" high duct.


C

B T

Note: A dimension is measured at base. Note: K dimension shown in mounting hole dimensions below.

Mounting Hole Dimensions For .5", .75", 1" and 1.5" wide duct.
.50 TYP [12.7] .20 TYP [5.0] C L

2.0 TYP [50.8]

2.0 [50.8]

For 2.0", 2.5", 3", 4" and 6" wide duct.

K K C L

>

2.0 TYP [50.8]

2.0 [50.8]

Note: For type FS raceway, no mounting holes is the standard condition; if mounting holes are required, delete NM from the part number.

>

.5 x .5 (12.7) (12.7) .5 x 1 (12.7) (25.4) .75 x .75 (19.1) (19.1) .75 x 1.5 (19.1) (38.1) 1x1 (25.4) (25.4) 1 x 1.5 (25.4) (38.1) 1x2 (25.4) (50.8) 1x3 (25.4) (76.2) 1x4 (25.4) (101.6) 1.5 x 1 (38.1) (25.4) 1.5 x 1.5 (38.1) (38.1) 1.5 x 2 (38.1) (50.8) 1.5 x 3 (38.1) (76.2) 1.5 x 4 (38.1) (101.6) 2x1 (50.8) (25.4) 2 x 1.5 (50.8) (38.1) 2x2 (50.8) (50.8) 2x3 (50.8) (76.2) 2x4 (50.8) (101.6) 2x5 (50.8) (127.0) 3x1 (76.2) (25.4) 3x2 (76.2) (50.8) 3x3 (76.2) (76.2) 3x4 (76.2) (101.6) 3x5 (76.2) (127.0) 4 x 1.5 (101.6) (38.1) 4x2 (101.6) (50.8) 4x3 (101.6) (76.2) 4x4 (101.6) (101.6) 4x5 (101.6) (127.0) 6x4 (152.4) (101.6)

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

.50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4) N/A 1.50 (38.1) 1.50 (38.1) 1.50 (38.1) 1.50 (38.1) N/A

C4. Cable Management

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

> Available for type FS raceway only. See page C1.48 for wiring duct color and size availability.

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.37

ELECTRICAL SOLUTIONS
A. System Overview

PANDUCT Type MC and TMC Wiring Duct Dimensions


Dimensions are shown for reference only. Contact PANDUIT customer service at 800-777-3300 for specific dimensional needs.
Duct Size (W x H)
For 25mm, 37.5mm, and 50mm high duct.

B1. Cable Ties


>

A 24.6 (.97) 24.6 (.97) 24.6 (.97) 24.6 (.97) 24.6 (.97) 37.1 (1.46) 37.1 (1.46) 37.1 (1.46) 37.1 (1.46) 49.5 (1.95) 49.5 (1.95) 49.5 (1.95) 62.0 (2.44) 62.0 (2.44) 74.7 (2.94) 74.7 (2.94) 74.7 (2.94) 74.7 (2.94) 99.6 (3.92) 99.6 (3.92) 99.6 (3.92) 99.6

B 23.6 (.93) 35.8 (1.41) 47.8 (1.88) 59.7 (2.35) 73.2 (2.88) 35.8 (1.41) 47.8 (1.88) 59.7 (2.35) 72.4 (2.85) 48.0 (1.89) 72.4 (2.85) 97.8 (3.85) 35.8 (1.41) 59.7 (2.35) 48.0 (1.89) 59.7 (2.35) 73.2 (2.88) 97.8 (3.85) 48.0 (1.89) 59.7 (2.35) 73.2 (2.88) 97.8

Dimensions mm (Inches) C D E F 24.6 (.97) 24.6 (.97) 24.6 (.97) 24.6 (.97) 24.6 (.97) 37.1 (1.46) 37.1 (1.46) 37.1 (1.46) 37.1 (1.46) 49.6 (1.95) 49.6 (1.95) 49.6 (1.95) 62.1 (2.44) 62.1 (2.44) 74.6 (2.94) 74.6 (2.94) 74.6 (2.94) 74.6 (2.94) 99.6 (3.92) 99.6 (3.92) 99.6 (3.92) 99.6 (3.92) 13.6 (.54) 24.7 (.97) 34.8 (1.37) 45.8 (1.80) 57.6 (2.27) 24.7 (.97) 34.8 (1.37) 45.8 (1.80) 57.6 (2.27) 34.8 (1.37) 57.6 (2.27) 81.0 (3.19) 24.7 (.97) 45.8 (1.80) 34.8 (1.37) 45.8 (1.80) 57.6 (2.27) 81.0 (3.19) 34.8 (1.37) 45.8 (1.80) 57.6 (2.27) 81.0 (3.19) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 5.0 (.20) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49) 12.5 (.49)

H 20.5 (.81) 33.0 (1.30) 45.5 (1.79) 58.0 (2.28) 70.5 (2.78) 33.0 (1.30) 45.5 (1.79) 58.0 (2.28) 70.5 (2.78) 45.5 (1.79) 70.5 (2.78) 95.5 (3.76) 33.0 (1.30) 58.0 (2.28) 45.5 (1.79) 58.0 (2.28) 70.5 (2.78) 95.5 (3.76) 45.5 (1.79) 58.0 (2.28) 70.5 (2.78) 99.5 (3.76)

T 1.4 (.06) 1.4 (.06) 1.5 (.06) 1.5 (.06) 1.7 (.07) 1.5 (.06) 1.7 (.07) 1.7 (.07) 1.8 (.07) 1.7 (.07) 1.9 (.08) 2.2 (.09) 1.7 (.07) 1.8 (.07) 2.0 (.08) 2.0 (.08) 2.2 (.09) 2.3 (.09) 2.0 (.08) 2.0 (.08) 2.5 (.10) 2.5 (.10)

25 x 25 (.98) x (.98) 25 x 37.5 (.98) x (1.48)

B2. Cable Accessories

B T

> > >

25 x 50 (.98) x (1.97) 25 x 62.5 (.98) x (2.46) 25 x 75 (.98) x (2.95) 37.5 x 37.5 (1.48) x (1.48) 37.5 x 50 (1.48) x (1.97) 37.5 x 62.5 (1.48) x (2.46) 37.5 x 75 (1.48) x (2.95) 50 x 50 (1.97) x (1.97) 50 x 75 (1.97) x (2.95) 50 x 100 (1.97) x (3.94) 62.5 x 37.5 (2.46) x (1.48) 62.5 x 62.5 (2.46) x (2.46) 75 x 50 (2.95) x (1.97) 75 x 62.5 (2.95) x (2.46) 75 x 75

B3. Stainless Steel Ties

C1. Wiring Duct

For 62.5mm, 75mm, and 100mm high duct.


C E

>

C2. Surface Raceway

B T

>
A F

>

C3. Abrasion Protection

Note: A dimension is measured at base. Note: K dimension shown in mounting hole dimensions below. >

C4. Cable Management

> >

D1. Terminals

Mounting Hole Dimensions For 25mm, 37.5mm, and 50mm width duct.
2000 mm [78.74]

>

D2. Power Connectors

14 mm [0.55]

>

D3. Grounding Connectors

8 mm [0.32] 1950 mm [76.77]

(2.95) x (2.95) > 75 x 100 (2.95) x (3.94) 100 x 50 (3.94) x (1.97) 100 x 62.5 (3.94) x (2.46) 100 x 75
12.5 mm [.49]

For 75mm and 100mm width duct.

E1. Labeling Systems

2000 mm [78.74] 50 mm [1.97]

>

E2. Labels

6.5 mm [.26]

25 mm [.98]

(3.94) x (2.95) > 100 x 100

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

(3.94) x (3.94) (3.92) (3.85) > Available for type MC wiring duct only.
4.5 mm [.18] 25 mm [.98]

1950 mm [76.77]

50 mm [1.97]

C1.38

ELECTRICAL SOLUTIONS
PANDUCT Type NNC Wiring Duct Dimensions

A. System Overview

Dimensions are shown for reference only. Contact PANDUIT customer service at 800-777-3300 for specific dimensional needs.
Duct Size (W x H)
For 25mm, 37.5mm, and 50mm high duct.
C

A 24.6 (.97) 24.6 (.97) 24.6 (.97) 24.6 (.97) 37.1 (1.46) 37.1 (1.46) 37.1 (1.46) 49.5 (1.95) 49.5 (1.95) 49.5 (1.95) 74.7 (2.94) 99.6 (3.92) 99.6 (3.92) 99.6 (3.92)

B 23.6 (.93) 35.8 (1.41) 47.8 (1.88) 72.4 (2.85) 35.8 (1.41) 47.8 (1.88) 72.4 (2.85) 47.8 (1.88) 72.4 (2.85) 97.8 (3.85) 72.4 (2.85) 47.8 (1.88) 72.4 (2.85) 97.8 (3.85)

Dimensions mm (Inches) C D 24.6 (.97) 24.6 (.97) 24.6 (.97) 24.6 (.97) 37.1 (1.46) 37.1 (1.46) 37.1 (1.46) 49.5 (1.95) 49.5 (1.95) 49.5 (1.95) 74.7 (2.94) 99.6 (3.92) 99.6 (3.92) 99.6 (3.92) 13.6 (.54) 24.6 (.97) 34.8 (1.37) 57.6 (2.27) 24.7 (.97) 34.8 (1.37) 57.6 (2.27) 34.8 (1.37) 57.6 (2.27) 81.0 (3.19) 57.6 (2.27) 34.8 (1.37) 57.6 (2.27) 81.0 (3.19)

H 20.3 (.80) 33.0 (1.30) 45.5 (1.79) 70.6 (2.78) 33.0 (1.30) 45.5 (1.79) 70.6 (2.78) 45.5 (1.79) 70.6 (2.78) 95.5 (3.76) 70.6 (2.78) 45.5 (1.79) 70.6 (2.78) 95.5 (3.76)

T 1.5 (.06) 1.8 (.07) 2.0 (.08) 2.0 (.08) 1.8 (.07) 2.0 (.08) 2.0 (.08) 2.0 (.08) 2.0 (.08) 2.3 (.09) 2.0 (.08) 2.0 (.08) 2.0 (.08) 2.3 (.09)

B1. Cable Ties

10.0 TYP [.39]


B H D

T A

25 x 25 (.98) x (.98) 25 x 37 (.98) x (1.48) 25 x 50 (.98) x (1.97) 25 x 75 (.98) x (2.95) 37.5 x 37.5 (1.48) x (1.48) 37.5 x 50 (1.48) x (1.97) 37.5 x 75 (1.48) x (2.95) 50 x 50 (1.97) x (1.97) 50 x 75 (1.97) x (2.95) 50 x 100 (1.97) x (3.94) 75 x 75 (2.95) x (2.95) 100 x 50 (3.94) x (1.97) 100 x 75 (3.94) x (2.95) 100 x 100 (3.92) x (3.85)

B2. Cable Accessories

25.0 TYP [.98]

B3. Stainless Steel Ties

For 75mm and 100mm high duct.


C

C1. Wiring Duct

10.0 TYP [.39]

B T

C2. Surface Raceway

25.0 TYP [.98]

C3. Abrasion Protection

Mounting Hole Dimensions For 25mm, 37.5mm, and 50mm width duct.
2000 mm [78.74] 14 mm [0.55]

C4. Cable Management

D1. Terminals

8 mm [0.32] 1950 mm [76.77]

D2. Power Connectors

For 75mm and 100mm width duct.


2000 mm [78.74] 50 mm [1.97] 6.5 mm [.26] 25 mm [.98] 12.5 mm [.49]

D3. Grounding Connectors

E1. Labeling Systems

4.5 mm [.18]

1950 mm [76.77]

50 mm [1.97]

25 mm [.98]

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.39

ELECTRICAL SOLUTIONS
A. System Overview

PANDUCT Type NE Wiring Duct Dimensions


Dimensions are shown for reference only. Contact PANDUIT customer service at 800-777-3300 for specific dimensional needs.
Duct Size (W x H)
For .5" high duct.

B1. Cable Ties

A .63 (16.0) .63 (16.0) 1.14 (29.0) 1.14 (29.0) 1.14 (29.0) 1.14 (29.0) 1.14 (29.0) 1.64 (41.7) 1.64 (41.7) 1.64 (41.7) 1.64 (41.7) 2.14 (54.4) 2.14 (54.4) 2.14 (54.4) 2.14 (54.4) 3.14 (79.8) 3.14 (79.8) 3.14 (79.8) 3.14 (79.8) 3.14 (79.8) 4.14 (105.2) 4.14 (105.2) 4.14 (105.2) 4.14 (105.2)

B .56 (14.2) 1.06 (26.9) 1.06 (26.9) 1.62 (41.1) 2.06 (52.3) 3.06 (77.7) 4.06 (103.1) 1.62 (41.1) 2.06 (52.3) 3.06 (77.7) 4.06 (103.1) 1.06 (26.9) 2.06 (52.3) 3.06 (77.7) 4.06 (103.1) 1.06 (26.9) 2.06 (52.3) 3.06 (77.7) 4.06 (103.1) 5.06 (128.5) 2.06 (52.3) 3.06 (77.7) 4.06 (103.1) 5.06 (128.5)

C .69 (17.5) .69 (17.5) 1.25 (31.8) 1.25 (31.8) 1.25 (31.8) 1.25 (31.8) 1.25 (31.8) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 4.25 (108.0) 4.25 (108.0) 4.25 (108.0) 4.25 (108.0)

Dimensions Inches (mm) D E F .38 (9.7) .75 (19.1) .75 (19.1) 1.20 (30.5) 1.63 (41.4) 2.63 (66.8) 3.63 (92.2) 1.20 (30.5) 1.63 (41.4) 2.63 (66.8) 3.63 (92.2) .75 (19.1) 1.63 (41.4) 2.63 (66.8) 3.63 (92.2) .75 (19.1) 1.63 (41.4) 2.63 (66.8) 3.63 (92.2) 4.63 (117.6) 1.63 (41.4) 2.63 (66.8) 3.63 (92.2) 4.63 (117.6) .37 (9.4) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .38 (9.7) .31 (7.9) .31 (7.9) .31 (7.9) .38 (9.7) .80 (20.3) .80 (20.3) .80 (20.3) .80 (20.3) .80 (20.3) 1.00 (25.4) 1.00 (25.4) .80 (20.3) .80 (20.3) 1.00 (25.4) 1.00 (25.4) .80 (20.3) .80 (20.3) 1.00 (25.4) 1.00 (25.4) .80 (20.3) .80 (20.3) 1.00 (25.4) 1.00 (25.4) 1.33 (33.8) .80 (20.3) 1.00 (25.4) 1.00 (25.4) 1.33 (33.8)

H .50 (12.7) 1.00 (25.4) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 1.50 (38.1) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 1.00 (25.4) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 1.00 (25.4) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 5.00 (127.0) 2.00 (50.8) 3.00 (76.2) 4.00 (101.6) 5.00 (127.0)

T .05 (1.3) .06 (1.5) .06 (1.5) .07 (1.8) .07 (1.8) .07 (1.8) .08 (2.0) .07 (1.8) .07 (1.8) .07 (1.8) .08 (2.0) .06 (1.5) .07 (1.8) .07 (1.8) .08 (2.0) .06 (1.5) .07 (1.7) .07 (1.8) .08 (2.0) .09 (2.3) .07 (1.8) .07 (1.8) .08 (2.0) .09 (2.3)

B2. Cable Accessories

D H

C1. Wiring Duct

For 1", 1.25", 1.5", 1.75", 2", 2.5", 3", 4" and 5" high duct.
F C

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

Mounting Hole Dimensions For .5", .75", 1" and 1.5" wide duct.
.50 TYP [12.7]

D1. Terminals

.195 TYP [5.0] C L

D2. Power Connectors

4.0 [101.6] TYP

2.0 [50.8]

D3. Grounding Connectors

For 2.0", 2.5", 3" and 4" wide duct.

.50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4) 1.50 (38.1) 1.50 (38.1) 1.50 (38.1) 1.50 (38.1)

3x4
K K C L

E1. Labeling Systems


4.0 [101.6] TYP

2.0 [50.8]

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

(76.2) (101.6) 3x5 (76.2) (127.0) 4x2 (101.6) (50.8) 4x3 (101.6) (76.2) 4x4 (101.6) (101.6) 4x5 (101.6) (127.0)

C1.40

ON CENTERLINE

B3. Stainless Steel Ties

.5 x .5 (12.7) (12.7) .5 x 1 (12.7) (25.4) 1x1 (25.4) (25.4) 1 x 1.5 (25.4) (38.1) 1x2 (25.4) (50.8) 1x3 (25.4) (76.2) 1x4 (25.4) (101.6) 1.5 x 1.5 (38.1) (38.1) 1.5 x 2 (38.1) (50.8) 1.5 x 3 (38.1) (76.2) 1.5 x 4 (38.1) (101.6) 2x1 (50.8) (25.4) 2x2 (50.8) (50.8) 2x3 (50.8) (76.2) 2x4 (50.8) (101.6) 3x1 (76.2) (25.4) 3x2 (76.2) (50.8) 3x3 (76.2) (76.2)

ELECTRICAL SOLUTIONS
PANDUCT Type H and HS Wiring Duct Dimensions

A. System Overview

Dimensions are shown for reference only. Contact PANDUIT customer service at 800-777-3300 for specific dimensional needs.
Duct Size (W x H) 1.5 x 2 (38.1) x (50.8) 1.5 x 3 (38.1) x (76.2) 2x2 (50.8) x (50.8) 2x3 (50.8) x (76.2) 2x4 (50.8) x (101.6) 3x3 (76.2) x (76.2) 3x4 (76.2) x (101.6) 4x4 (101.6) x (101.6)
D H

100 C

A 1.75 (44.5) 1.75 (44.5) 2.17 (55.1) 2.17 (55.1) 2.17 (55.1) 3.25 (82.6) 3.25 (82.6) 4.25 (108.0)

B 1.98 (50.3) 3.06 (77.7) 1.98 (50.3) 3.06 (77.7) 4.1 (104.1) 3.06 (77.7) 4.1 (104.1) 4.1 (104.1)

C 1.88 (47.8) 1.88 (47.8) 2.29 (58.2) 2.29 (58.2) 4.38 (111.3) 3.38 (85.9) 3.38 (85.9) 4.38 (111.3)

Dimensions Inches (mm) D E F 1.63 (41.4) 2.63 (66.8) 1.57 (39.9) 2.63 (66.8) 3.63 (92.2) 2.63 (66.8) 3.63 (92.2) 3.63 (92.2) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .31 (7.9) .80 (20.3) 1.00 (25.4) .80 (20.3) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4) 1.00 (25.4)

H 1.92 (48.8) 3.00 (76.2) 1.92 (48.8) 3.00 (76.2) 4.00 (101.6) 3.00 (76.2) 4.00 (101.6) 4.00 (101.6)

T .08 (2.0) .10 (2.5) .08 (2.0) .10 (2.5) .10 (2.7) .10 (2.5) .11 (2.8) .11 (2.8)

B1. Cable Ties

On CL

B T

.50 (12.7) .50 (12.7) .50 (12.7) 1.00 (25.4) 1.00 (25.4) 1.50 (38.1)

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

For 2", 3", and 4" wide duct.

K E E F .31" [7.9] .80" [20.3] .31" [7.9] 1.00" [25.4] K C L

C3. Abrasion Protection

For 2" duct height: 3" to 4" duct height:

4.0 [101.6] TYP

2.0 [50.8]

C4. Cable Management

PANDUCT Type HN Wiring Duct Dimensions

D1. Terminals

Dimensions are shown for reference only. Contact PANDUIT customer service at 800-777-3300 for specific dimensional needs.
Duct Size (W x H)
100

A 1.75 (44.5) 1.75 (44.5) 2.17 (55.1) 2.17 (55.1) 2.17 (55.1) 3.25 (82.6) 3.25 (82.6) 4.25 (108.0)

B 1.98 (50.3) 3.06 (77.7) 1.98 (50.3) 3.06 (77.7) 4.1 (104.1) 3.06 (77.7) 4.1 (104.1) 4.1 (104.1)

C 1.88 (47.8) 1.88 (47.8) 2.29 (58.2) 2.29 (58.2) 4.38 (111.3) 3.38 (85.9) 3.38 (85.9) 4.38 (111.3)

Dimensions Inches (mm) D E F 1.63 (41.4) 2.63 (66.8) 1.57 (39.9) 2.63 (66.8) 3.63 (92.2) 2.63 (66.8) 3.63 (92.2) 3.63 (92.2) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .20 (5.0) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7)

H 1.92 (48.8) 3.00 (76.2) 1.92 (48.8) 3.00 (76.2) 4.00 (101.6) 3.00 (76.2) 4.00 (101.6) 4.00 (101.6)

T .08 (2.0) .10 (2.5) .08 (2.0) .10 (2.5) .10 (2.7) .10 (2.5) .11 (2.8) .11 (2.8)

D2. Power Connectors

1.5 x 2 (38.1) x (50.8) 1.5 x 3 (38.1) x (76.2) 2x2 (50.8) x (50.8) 2x3 (50.8) x (76.2) 2x4 (50.8) x (101.6) 3x3 (76.2) x (76.2) 3x4 (76.2) x (101.6) 4x4 (101.6) x (101.6)

On CL

D3. Grounding Connectors

.50 (12.7) .50 (12.7) .50 (12.7) 1.00 (25.4) 1.00 (25.4) 1.50 (38.1)

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification

For 2", 3", and 4" wide duct.


D H

K K C L

Multiple slot restrictors present with 2" and greater duct wall height.

2.0 TYP [50.8]

2.0 [50.8]

E5. Lockout/ Tagout & Safety Solutions F. Index

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.41

ELECTRICAL SOLUTIONS
A. System Overview

PANDUCT Type FL Wiring Duct Dimensions


Dimensions are shown for reference only. Dimensions are in mm (in.). Contact PANDUIT customer service at 800-777-3300 for specific dimensional needs.
Mounting Hole Dimensions For FL12X12LG-A

B1. Cable Ties

B2. Cable Accessories

25.0 TYP [.98] 5.0 TYP [.20] 8.0 TYP [.31]

B3. Stainless Steel Ties

12.5 [.49] C L

Nominal Duct Size (W x H) mm 12 x 12 (.49) x (.49) 25 x 25 (.98) x (.98) 50 x 50 (1.97) x (1.97)

Dimensions mm (In.) A B 12.4 12.4 (.49) (.49) 24.9 (.98) 50 (1.97) 24.9 (.98) 50 (1.97)

C1. Wiring Duct

6.2 TYP [.25]

4.0 TYP [.16]

For FL25X25LG-A and FL50X50LG-A


12.5 TYP [.49] 12.5 [.49] B C L

Note: Type FL wiring duct has factory applied adhesive. For 50 x 50 two strips of tape are used; otherwise, only one strip is centered on the part.

C2. Surface Raceway

C3. Abrasion Protection

Note: B dimension is without adhesive.

C4. Cable Management

25.0 TYP [.98]

D1. Terminals

PANDUCT PANELMAX Corner Wiring Duct Wirefill Capacity


Electrical Communication 16 AWG .096 .111 .118 .084 18 AWG .100 .106 22 23 23/24 24 Fiber AWG AWG AWG AWG Cable .085 .330 .250 Cat. 6 140 215 .190 Cat. 5e 243 372 .118 3.0 mm 630 964 8 10 AWG AWG Nominal Duct Size (W x H) In. CWD3 4.4 x 3.6 CWD4 5.4 x 4.6 .216 .164 .130 12 AWG .141 .152 .111 14 AWG .124 .133

D2. Power Connectors

D3. Grounding Connectors

Cat. Area THHN THHN THHN MTW MTW THHN MTW MTW TFFN MTW MTW TFFN MTW MTW MTW 6A In. 17.580 188 326 520 442 380 713 571 496 953 713 631 1245 879 782 1216 80 26.920 288 500 796 677 582 1092 875 760 1460 1092 966 1907 1346 1197 1862
2

123

Table shows maximum wirefill based on 50% of duct internal cross sectional area. Formula = area/2.00 x D .

E1. Labeling Systems

PANDUCT Type H, HN and HS Wiring Duct Wirefill Capacity


Electrical Communication 16 AWG .133 .096 .111 .118 .084 18 AWG .100 .106 22 23 23/24 24 Fiber AWG AWG AWG AWG Cable .085 .330 .250 Cat. 6 25 38 34 51 69 77 103 138 .190 Cat. 5e 44 67 59 89 119 134 179 239 .118 3.0 mm 116 174 154 232 309 348 464 619 8 10 AWG AWG Nominal Duct Size (W x H) In. 1.50 x 2.00 1.50 x 3.00 2.00 x 2.00 2.00 x 3.00 2.00 x 4.00 3.00 x 3.00 3.00 x 4.00 4.00 x 4.00 Nominal Area In. 3.000 4.500 4.000 6.000 8.000 9.000 12.000 16.000 .216 .164 .130 12 AWG .141 .152 .111 14 AWG .124

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

Cat. THHN THHN THHN MTW MTW THHN MTW MTW TFFN MTW MTW TFFN MTW MTW MTW 6A 34 60 95 81 70 131 105 91 175 131 116 229 162 144 224 14 52 46 69 92 104 139 185 90 80 120 160 180 241 321 143 127 191 255 287 383 511 122 108 163 217 244 326 435 105 93 140 187 210 280 374 197 175 263 350 394 526 701 158 140 210 281 316 421 562 137 122 183 244 275 366 488 263 234 351 469 527 703 938 197 175 263 350 394 526 701 174 155 232 310 349 465 621 344 306 459 612 689 919 1225 243 216 324 432 486 648 864 216 192 288 384 432 577 769 336 299 448 598 673 897 1197 22 19 29 39 44 59 79

Table shows maximum wirefill based on 50% of duct internal cross sectional area. Formula = nominal area/1.85 x D2. See page C1.48 for wiring duct color and size availability. AWG dimensions represent typical outer cable diameter in inches.

C1.42

ELECTRICAL SOLUTIONS
PANDUCT Type D, G, F and FS Wiring Duct Wirefill Capacity
Electrical 8 10 AWG AWG Nominal Duct Size (W x H) In. 0.50 x 0.50 0.50 x 1.00 0.50 x 2.00 0.50 x 4.00 0.75 x 0.75 0.75 x 1.00 0.75 x 1.50 0.75 x 2.00 1.00 x 1.00 1.00 x 1.50 1.00 x 2.00 1.00 x 3.00 1.00 x 4.00 1.50 x 1.00 1.50 x 1.50 1.50 x 2.00 1.50 x 3.00 1.50 x 4.00 2.00 x 1.00 2.00 x 1.50 2.00 x 2.00 2.00 x 3.00 2.00 x 4.00 2.00 x 5.00 2.50 x 3.00 3.00 x 1.00 3.00 x 2.00 3.00 x 3.00 3.00 x 4.00 3.00 x 5.00 4.00 x 1.50 4.00 x 2.00 4.00 x 3.00 4.00 x 4.00 4.00 x 5.00 6.00 x 4.00 Nominal Area In. 0.250 0.500 1.000 2.000 0.563 0.750 1.125 1.500 1.000 1.500 2.000 3.000 4.000 1.500 2.250 3.000 4.500 6.000 2.000 3.000 4.000 6.000 8.000 10.000 7.500 3.000 6.000 9.000 12.000 15.000 6.000 8.000 12.000 16.000 20.000 24.000 .216 .164 .13 12 AWG .141 .152 .111 14 AWG .124 .133 .096 16 AWG .111 .118 .084 18 AWG .100 .106 Communication 22 23 23/24 24 Fiber AWG AWG AWG AWG Cable .085 .330 .25 Cat. 6 2 4 9 18 5 6 10 13 9 13 18 27 36 13 20 27 41 54 18 27 36 54 73 91 68 27 54 82 109 137 54 73 109 146 182 219 .190 Cat. 5e 3 7 15 31 8 11 17 23 15 23 31 47 63 23 35 47 71 94 31 47 63 94 126 158 118 47 94 142 189 237 94 126 189 253 316 379 .118 3.0 mm 10 20 40 81 23 30 46 61 40 61 81 122 163 61 92 122 184 245 81 122 163 245 327 409 307 122 245 368 491 614 245 327 491 655 819 983

A. System Overview

B1. Cable Ties

Cat. THHN THHN THHN MTW MTW THHN MTW MTW TFFN MTW MTW TFFN MTW MTW MTW 6A 3 5 8 7 6 11 9 8 15 11 10 20 14 12 19 1 6 12 24 6 9 13 18 12 18 24 36 48 18 27 36 55 73 24 36 48 73 97 122 91 36 73 110 146 183 73 97 146 195 244 293 10 21 42 11 15 23 31 21 31 42 63 84 31 47 63 95 127 42 63 84 127 169 212 159 63 127 191 254 318 127 169 254 339 424 509 16 33 67 19 25 38 50 33 50 67 101 135 50 76 101 152 202 67 101 135 202 270 338 253 101 202 304 405 507 202 270 405 540 676 811 14 28 57 16 21 32 43 28 43 57 86 114 43 64 86 129 172 57 86 114 172 229 287 215 86 172 258 344 431 172 229 344 459 574 689 12 24 49 13 18 27 37 24 37 49 74 98 37 55 74 111 148 49 74 98 148 197 247 185 74 148 222 296 370 148 197 296 395 494 593 23 46 92 26 34 52 69 46 69 92 139 185 69 104 139 208 278 92 139 185 278 371 463 347 139 278 417 556 695 278 371 556 742 927 1113 18 37 74 20 27 41 55 37 55 74 111 148 55 83 111 167 222 74 111 148 222 297 371 278 111 222 334 445 557 222 297 445 594 743 891 16 32 64 18 24 36 48 32 48 64 96 129 48 72 96 145 193 64 96 129 193 258 323 242 96 193 290 387 484 193 258 387 516 646 775 31 62 124 34 46 69 93 62 93 124 186 248 93 139 186 279 372 124 186 248 372 496 620 465 186 372 558 744 930 372 496 744 992 1240 23 46 92 26 34 52 69 46 69 92 139 185 69 104 139 208 278 92 139 185 278 371 463 347 139 278 417 556 695 278 371 556 742 927 20 41 82 23 30 46 61 41 61 82 123 164 61 92 123 184 246 82 123 164 246 328 410 307 123 246 369 492 615 246 328 492 656 820 984 40 80 161 45 60 91 121 80 121 161 242 323 121 182 242 364 485 161 242 323 485 647 809 607 242 485 728 971 1214 485 647 971 1295 28 57 114 32 42 64 85 57 85 114 171 228 85 128 171 257 342 114 171 228 342 457 571 428 171 342 514 685 857 342 457 685 914 25 50 101 28 38 57 76 50 76 101 152 203 76 114 152 228 305 101 152 203 305 406 508 381 152 305 457 610 762 305 406 610 813 39 79 158 44 59 88 118 79 118 158 237 316 118 177 237 355 474 158 237 316 474 632 790 593 237 474 711 949 1186 474 632 949 1265 2 5 10 2 3 5 7 5 7 10 15 20 7 11 15 23 31 10 15 20 31 41 52 39 15 31 47 62 78 31 41 62 83 104 125

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

1619 1142 1017 1581 1943 1371 1220 1898


2

1488 1113

E1. Labeling Systems

Table shows maximum wirefill based on 50% of duct internal cross sectional area. Formula = nominal area/1.75 x D . See page C1.48 for wiring duct color and size availability. Not all sizes available for each duct type. AWG dimensions represent typical outer cable diameter in inches.

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.43

ELECTRICAL SOLUTIONS
A. System Overview

PANDUCT Type MC, NNC and TMC Wiring Duct Wirefill Capacity
Electrical Communication 16 AWG 3.4 2.4 2.8 3 2.1 18 AWG 2.5 2.7 22 23 23/24 24 Fiber AWG AWG AWG AWG Cable 2.2 8.4 6.4 Cat. 6 8 13 17 21 26 19 26 32 39 35 53 70 32 54 53 65 79 106 70 87 106 141 4.8 Cat. 5e 15 22 30 38 46 33 45 56 68 61 92 122 56 94 92 114 138 184 122 152 184 245 3 3.0 mm 39 58 79 98 119 86 117 145 176 158 238 317 145 244 238 295 357 476 317 393 476 634 8 10 AWG AWG Nominal Duct Size (W x H) mm 25 x 25 25 x 37 25 x 50 Nominal Area mm 625 925 1250 1550 1875 1369 1850 2294 2775 2500 3750 5000 2294 3844 3750 4650 5625 7500 5000 6200 7500 10000 5.5 4.2 3.3 12 AWG 3.6 3.9 2.8 14 AWG 3.1

B1. Cable Ties

B2. Cable Accessories

Cat. THHN THHN THHN MTW MTW THHN MTW MTW TFFN MTW MTW TFFN MTW MTW MTW 6A 11 20 32 27 23 44 36 31 60 44 39 78 55 49 76 5 17 23 29 35 25 35 43 52 47 71 94 43 72 71 88 106 142 94 117 142 189 30 41 51 61 45 60 75 91 82 123 164 75 126 123 153 185 246 164 204 246 329 48 65 81 98 71 96 120 145 131 196 262 120 201 196 243 294 393 262 324 393 524 41 55 69 83 60 82 102 123 111 167 222 102 171 167 207 250 334 222 276 334 445 35 47 59 71 52 70 87 106 95 143 191 87 147 143 178 215 287 191 237 287 383 66 89 111 134 98 132 164 199 179 269 359 164 276 269 334 404 539 359 445 539 718 53 72 89 108 78 106 132 159 144 216 288 132 221 216 267 324 432 288 357 432 576 46 62 77 93 68 92 114 138 125 187 250 114 192 187 232 281 375 250 310 375 500 88 120 148 180 131 177 220 266 240 360 480 220 369 360 446 540 720 480 595 720 961 66 89 111 134 98 132 164 199 179 269 359 164 276 269 334 404 539 359 445 539 718 58 79 98 119 87 117 145 176 159 238 318 145 244 238 295 357 477 318 394 477 636 116 156 194 235 171 232 287 348 313 470 627 287 482 470 583 706 941 627 778 941 1255 81 110 137 166 121 163 203 245 221 332 442 203 340 332 411 498 664 442 549 664 885 72 98 122 147 107 145 180 218 197 295 394 180 303 295 366 443 591 394 488 591 788 113 153 190 229 167 226 281 340 306 459 612 281 471 459 570 689 919 612 760 919 1225 7 10 12 15 11 15 18 22 20 30 40 18 31 30 37 45 60 40 50 60 81

B3. Stainless Steel Ties

25 x 62 25 x 75 37 x 37 37 x 50 37 x 62 37 x 75 50 x 50 50 x 75 50 x 100 62 x 37 62 x 62 75 x 50 75 x 62 75 x 75 75 x 100 100 x 50 100 x 62 100 x 75 100 x 100

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

Table shows maximum wirefill based on 50% of duct internal cross sectional area. Formula = nominal area/1.75 x D2. See page C1.48 for wiring duct color and size availability. Not all sizes available for each duct type. AWG dimensions represent typical outer cable diameter in millimeters.

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

C1.44

ELECTRICAL SOLUTIONS
PANDUCT Type NE Wiring Duct Wirefill Capacity
Electrical 8 10 AWG AWG Nominal Duct Size (W x H) In. 0.50 x 0.50 0.50 x 1.00 1.00 x 1.00 1.00 x 1.50 1.00 x 2.00 1.00 x 3.00 1.00 x 4.00 1.50 x 1.50 1.50 x 2.00 1.50 x 3.00 1.50 x 4.00 2.00 x 1.00 2.00 x 2.00 2.00 x 3.00 2.00 x 4.00 3.00 x 1.00 3.00 x 2.00 3.00 x 3.00 3.00 x 4.00 3.00 x 5.00 4.00 x 2.00 4.00 x 3.00 4.00 x 4.00 4.00 x 5.00 Nominal Area In. 0.250 0.500 1.000 1.500 2.000 3.000 4.000 2.250 3.000 4.500 6.000 2.000 4.000 6.000 8.000 3.000 6.000 9.000 12.000 15.000 8.000 12.000 16.000 20.000 .216 .164 .130 12 AWG .141 .152 .111 14 AWG .124 .133 .096 16 AWG .111 .118 .084 18 AWG .100 .106 Communication 22 23 23/24 24 Fiber AWG AWG AWG AWG Cable .085 .330 .25 Cat. 6 2 4 8 12 16 24 32 18 24 36 48 16 32 48 64 24 48 72 96 120 64 96 128 160 .190 Cat. 5e 3 6 13 20 27 41 55 31 41 62 83 27 55 83 110 41 83 124 166 207 110 166 221 277 .118 3.0 mm 8 17 35 53 71 107 143 80 107 161 215 71 143 215 286 107 215 322 430 537 286 430 573 716

A. System Overview

B1. Cable Ties

Cat. THHN THHN THHN MTW MTW THHN MTW MTW TFFN MTW MTW TFFN MTW MTW MTW 6A 2 5 10 16 21 32 42 24 32 48 64 21 42 64 85 32 64 96 128 160 85 128 171 214 4 9 18 27 37 55 74 41 55 83 111 37 74 111 148 55 111 167 223 278 148 223 297 371 7 14 29 44 59 88 118 66 88 133 177 59 118 177 236 88 177 266 355 443 236 355 473 591 6 12 25 37 50 75 100 56 75 113 150 50 100 150 201 75 150 226 301 377 201 301 402 502 5 10 21 32 43 64 86 48 64 97 129 43 86 129 173 64 129 194 259 324 173 259 346 432 10 20 40 60 81 121 162 91 121 182 243 81 162 243 324 121 243 365 486 608 324 486 649 811 8 16 32 48 65 97 130 73 97 146 195 65 130 195 260 97 195 292 390 487 260 390 520 650 7 14 28 42 56 84 113 63 84 127 169 56 113 169 226 84 169 254 339 423 226 339 452 565 13 27 54 81 108 162 217 122 162 244 325 108 217 325 434 162 325 488 651 813 434 651 868 1085 10 20 40 60 81 121 162 91 121 182 243 81 162 243 324 121 243 365 486 608 324 486 649 811 8 17 35 53 71 107 143 80 107 161 215 71 143 215 287 107 215 323 430 538 287 430 574 718 17 35 70 106 141 212 283 159 212 318 425 141 283 425 566 212 425 637 850 1062 566 850 1133 12 25 50 75 100 150 200 112 150 225 300 100 200 300 400 150 300 450 600 750 400 600 800 11 22 44 66 88 133 177 100 133 200 266 88 177 266 355 133 266 400 533 667 355 533 711 889 17 34 69 103 138 207 276 155 207 311 415 138 276 415 553 205 415 622 830 1038 553 830 1107 1384 1 2 4 6 9 13 18 10 13 20 27 9 18 27 36 13 27 41 55 68 36 55 73 91

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

1417 1000

D1. Terminals

Table shows maximum wirefill based on 50% of duct internal cross sectional area. Formula = nominal area/2.00 x D2. AWG dimensions represent typical outer cable diameter in inches.

D2. Power Connectors

PANDUCT Type FL Wiring Duct Wirefill Capacity


Electrical 8 10 AWG AWG Nominal Duct Size (W x H) mm 12 x 12 25 x 25 50 x 50 Nominal Area mm 144 625 2500 5.5 4.2 3.3 12 AWG 3.6 3.9 2.8 14 AWG 3.1 3.4 2.4 16 AWG 2.8 3.0 2.1 18 AWG 2.5 2.7 Communication 22 23 23/24 24 Fiber AWG AWG AWG AWG Cable 2.2 8.4 Cat. 6A 0 3 14 6.4 Cat. 6 1 6 24 4.8 Cat. 5e 2 10 42 3.0 3.0 mm 6 27 111

D3. Grounding Connectors

E1. Labeling Systems

THHN THHN THHN MTW MTW THHN MTW MTW TFFN MTW MTW TFFN MTW MTW MTW 1 3 5 4 3 7 5 5 9 7 6 12 8 7 12 8 33 14 57 22 91 19 77 16 67 31 125 25 100 21 87 42 168 31 125 27 111 54 219 38 155 34 137 53 214

E2. Labels

Table shows maximum wirefill based on 50% of duct internal cross sectional area. Formula = nominal area/2.50 x D2. AWG dimensions represent typical outer cable diameter in millimeters.

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.45

ELECTRICAL SOLUTIONS
A. System Overview

Wirefill Formula
General Formula
PANDUIT Wiring Duct wirefills are calculated using the following general formula:

B1. Cable Ties

B2. Cable Accessories

B3. Stainless Steel Ties

Why use a 50% Wirefill?


As specified in NFPA79-2007 section 13.5.2, Percentage Fills of Raceways (Ducts), a 50% wirefill is given as the maximum wirefill capacity in all PANDUIT Wiring Ducts. This helps ensure general safe wiring practices are followed. In actual practice, a 50% wirefill is the maximum amount of wiring the duct can hold given the additional airspace created between cables by non-uniform cable shapes, cable interlacing, and cable packing factors.

C1. Wiring Duct

C2. Surface Raceway

What is the Usable Duct Area?


The usable area we define as the calculation of internal area that can be occupied by wires or cables. Calculation of Internal Area
Since we use the outer channel dimensions in our calculation we make an adjustment in our formula for the thickness of material and for design elements that extend inside the channel.

C3. Abrasion Protection

Air Space Allotment


In our wirefill formula an adjustment is made to the channel internal area to account for unusable air space that will be present between cables when placed in the channel. Our formula assumes a uniform close packed or high-density cable arrangement (see diagram) (Note 1).

C4. Cable Management

D1. Terminals

D2. Power Connectors

Considering these factors the usable duct area is equal to an average of 90% of the nominal area, or (W x H) x .90.

D3. Grounding Connectors

Wire Area
The wire area formula is converted to allow calculation using the cable diameter:

E1. Labeling Systems

E2. Labels

Formula Derivation
E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

Inserting the elements from above into the general formula results in the following:

Simplifying this formula results in the formula used for wirefill calculation (Note 2):

Note: When calculating wirefill capacity using the above formula, variables W, H and D must be expressed in same units (i.e. mm or inches).
1 This calculation does not account for additional airspace created between cables by non-uniform cable shapes, cable interlacing, and cable packing factors. 2 The resulting formula is used for all PANDUIT flush cover ducts, this excludes type NE duct which has a different profile design that results in a divisor of 2.0 x D 2 (rather than 1.75 x D 2 as shown here) and type H and HS wiring duct with a profile design that results in a divisor of 1.85 x D 2 and corner wiring duct which uses calculated internal area and a divisor of 2.0 x D 2.

C1.46

ELECTRICAL SOLUTIONS
PANDUCT Wiring Duct and Raceway Material Specifications

A. System Overview

Properties

Units g/cc F 10 5 in./in./F


(BTU-in./hr-ft. )F
2

Test Method ASTM D 792 ASTM D 648 ASTM D 696 ASTM C 177 UL 94 ASTM E 662 ASTM D 2863 ASTM E 1354 ASTM D 2240 ASTM D 785 ASTM D 638 ASTM D 638 ASTM D 790 ASTM D 790 ASTM D 256

LeadFree PVC 1.45 156 3.7 1.3 V-0 538 35 N/A 78 111 6,200 390,000 8,700 325,000

HalogenFree Modified PPO (NNC) 1.09 215 3.8 1.3 V-0 513 30 N/A N/A 116 7,700 350,000 11,500 340,000

NORYL* (NE) 1.08 212 3.8 1.1 V-1 782 30 N/A 85 115 6,900 380,000 11,400 365,000

Polypropylene (FL) .95 117 N/A N/A V-2 N/A 25 N/A N/A N/A 3,770 172,000 4,350 181,250

Low Smoke/ Low Toxicity (TMC) 1.56 222 3.8 N/A V-0 92 58 49.3 N/A 118 6,600 316,000 11,900 317,000

B1. Cable Ties

General
Specific gravity Heat deflection temperature @264 psi Thermal expansion Thermal conductivity

B2. Cable Accessories

B3. Stainless Steel Ties

Burning Characteristics
Flammability class Smoke density @ 4 minutes Limited oxygen index (LOI) Peak heat release rate kW/m2 D R psi psi psi psi
C1. Wiring Duct

Hardness
Durometer hardness Rockwell hardness

C2. Surface Raceway

Tensile
Yield strength Modulus

C3. Abrasion Protection

Flexural
Yield strength Modulus

C4. Cable Management

Impact strength
Notched Izod (.125) 23C (73F) 0C (32F) ft.-lb./in. ft.-lb./in. ASTM D 150 ASTM D 150 ASTM D 149 volts/mil volts/mil 690 700 N/A N/A 400 N/A N/A N/A N/A N/A 3.90 3.30 N/A N/A 2.65 N/A N/A N/A N/A N/A 2.90 4.00 N/A N/A N/A N/A N/A N/A N/A N/A 4.0 1.6 5.0 2.0 5.0 N/A 1.8 N/A 3.0 N/A
D1. Terminals

Electrical Properties
Power factor: 60 Hz @30C (86F) 1 MHz @30C (86F) Dielectric constant: 60 Hz @30C (86F) 1 MHz @30C (86F) Dielectric strength: Unconditioned Conditioned

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

Note: To the best of our knowledge the above information is accurate. PANDUIT assumes no liability for the accuracy or completeness of this information.

E2. Labels

Rigid Polyvinyl Chloride (PVC)


A general purpose material for use in indoor applications. PVC has a UL flammability rating of V-0 and is UL 94 Recognized for continuous use temperatures up to 122F (50C). PVC is an economical wiring duct material.

Halogen-Free (Modified PPO)


A special purpose material for use in halogen-free or high temperature applications. Modified PPO has a UL 94 flammability rating of V-0 and is UL Recognized for continuous use temperatures up to 203F (95C), and is 20% lighter than PVC.

NORYL* Halogen-Free
A special purpose material for use in halogen-free or high temperature applications. NORYL* has a UL 94 flammability rating of V-1 and is UL Recognized for continuous use temperatures up to 203F (95C), and is 20% lighter than PVC.

Polypropylene
A flexible material with a UL 94 flammability rating of V-2 and that is UL Recognized for continuous use temperatures up to 149F (65C).

Low Smoke/ Low Toxicity


A special purpose material for use where low smoke, low toxicity and low flammability characteristics are critical. Ideally suited for transportation industry regulations. Low smoke/ low toxicity has a UL 94 flammability rating of V-0 and is UL Recognized for continuous use temperatures up to 176F (80C).

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

*NORYL is a registered trademark of General Electric Company. For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.47

ELECTRICAL SOLUTIONS
A. System Overview

PANDUCT Wiring Duct and Raceway Color and Size Selection

B1. Cable Ties


Duct Size WxH In. mm .5 x .5 12 x 12 .5 x 1 .5 x 2 .5 x 4 .75 x .75 .75 x 1 .75 x 1.5 .75 x 2 1x1 25 x 25 1 x 1.5 25 x 37 1x2 25 x 50 1 x 2.5 25 x 62 1x3 25 x 75 1x4 25 x 100 1.5 x 1 1.5 x 1.5 37 x 37 1.5 x 2 37 x 50 1.5 x 2.5 37 x 62 1.5 x 3 37 x 75 1.5 x 4 2x1 2 x 1.5 2x2 50 x 50 2x3 50 x 75 2x4 50 x 100 2x5 2.5 x 1.5 62 x 37 2.5 x 2.5 62 x 62 2.5 x 3 3x1 3x2 75 x 50 3 x 2.5 75 x 62 3x3 75 x 75 3x4 75 x 100 3x5 4 x 1.5 4x2 100 x 50 4 x 2.5 100 x 62 4x3 100 x 75 4x4 100 x 100 4x5 6x4 G G G G G G G G G G G G G G G G G G G G G G G G F F FS FS

B2. Cable Accessories

LG Light Gray FL G G G G G G G G G G G G G G G G G G G G G G G G F F FS

B3. Stainless Steel Ties

WH White NE NE

BL Black

IG IB Intl. Intrinsic BR Blue* Beige Gray

F F F F F F F F F F F F F F F F F F

FS

F F F F F F F F F F F F F F F F F F FS NE NE NE D D FS FS NE NE G NNC MC G NNC MC G NNC MC G MC NNC MC G G G G G G G FS FS D D D FS D D D H H G G G G G G G G G F F F F F F F F F TMC MC MC MC MC MC

C1. Wiring Duct

C2. Surface Raceway

FS FS FS D FS D FS D FS FS FS D FS D D FS FS FS D FS D FS D

NNC FL NNC NNC NNC

TMC

C3. Abrasion Protection

NNC H HN HS NNC H HN HS NNC

C4. Cable Management

D D FS FS FS FS

NE NNC MC NE H HN HS NNC MC MC NE H HN HS NNC MC NE NE

MC MC MC MC

D1. Terminals

H HN HS NNC FL H HN HS NNC H HN HS NNC

D D D

NE H HN HS NNC MC G NE H HN HS NNC MC G NE H HN HS NNC MC G MC MC

D D D

H H H

HS

G G G

F F F

TMC

MC MC MC MC MC

D2. Power Connectors

G G G G G G G G G G G G

F F F F F F F F F F

D FS FS D FS D FS D FS FS FS D FS D FS D FS FS H HN HS NNC H HN HS

G F G F G F G G G G G G G G G F F F F F F F

FS FS FS FS FS FS FS FS D D

NE NE NE

G FS FS D D H H G G F F TMC TMC MC MC MC MC

D3. Grounding Connectors

MC G MC NE H HN HS NNC MC G NE H HN HS MC G NE NE NNC MC G MC NE NNC MC G NE H HN HS NNC MC G NE G

E1. Labeling Systems

NNC NNC H HN HS NNC

D G G F F

TMC TMC

FS

HS

MC MC MC MC

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

*Intrinsic Blue Color IB


Intrinsic blue wiring duct is made from the same lead-free PVC material as our standard PVC duct. Intrinsic blue is an internationally recognized standard blue color that identifies the wiring duct as incapable of releasing sufficient electrical or thermal energy under normal or abnormal conditions to cause ignition of a specific hazardous atmospheric mixture in its most easily ignited concentrations. *ISA-RD12.6 (Instrument Society of America)

C1.48

ELECTRICAL SOLUTIONS
Installation Tips:
Application of Latex Paint on PANDUCT Wiring Duct
The following is recommended to properly prepare the surface of the wiring duct/raceway and covers for the best adhesion of latex paint: 1. Clean surface with mild soap and water solution or mineral spirits with a clean lint free towel. Allow to dry. 2. Using a sanding pad (such as synthetic stripping pad or medium/fine steel wool), slightly roughen the surface to be painted. 3. Apply a coat of all-purpose 100% acrylic primer and allow to dry. 4. Apply the desired topcoat of latex paint and allow to dry. 5. Install the wiring duct/raceway and covers.
B1. Cable Ties A. System Overview

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

Cutting Wiring Duct and Cover


For small quantities, use the DCT duct cutting tool on page C1.34. For larger quantities use a miter cutting saw blade for clean burr-free cuts. Recommended blade: Carbide 80T or 100T; .90" thickness, .125 kerf.

C2. Surface Raceway

Recommended Precaution when Using Type NNC and NE Wiring Duct


Cleaning solvents and cutting fluids that contain any of the following chemical agents should not come in contact with type NNC or type NE wiring duct. These chemicals are known to cause stress cracking in the halogen-free PPO material. Hydrocarbons Phenols Ketones Amines Ethers Organic, inorganic and oxidizing acids Petrol
Note: PANDUIT assumes no liability for the accuracy or completeness of this list.

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

Part Number System for Wiring Duct G


Type G

E1. Labeling Systems

.5
Nominal Width

.5
Nominal Height In. or mm

LG
Color

6
Length

-A
E2. Labels

= Wide Slot In. or mm Flush Design F = Narrow Slot Flush Design FL = Flexible Duct FS = Solid Wall Flush Design H = Wide Slot Hinged Design HN = Narrow Slot Hinged Design HS = Solid Wall Hinged Design D = Round Hole Flush Design NNC = Halogen-Free Design NE = NORYL* Wide Slot Design MC = Metric Narrow Slot Design TMC = Low Smoke Metric Design CWD = Corner Wiring Duct

Ft. or m LG = Light Gray WH = White BL = Black IB = Intrinsic Blue BR = Beige IG = International Gray

-A = Adhesive Backed = Without Adhesive (leave blank) NM = No Mounting Holes

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

*NORYL is a registered trademark of General Electric Company. For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.49

ELECTRICAL SOLUTIONS
A. System Overview

PANDUIT Wiring Duct Approvals and Compliances

B1. Cable Ties

B2. Cable Accessories

Logo (Symbol)

Agency Underwriters Laboratories, Inc.

Spec/Approval File No. E147128

Requirement UL Standard 1565 Positioning Devices. CSA Standard C22.2 No.18.5-02 Positioning Devices. UL Standard 1565 Positioning Devices.

Applicable Products Wiring duct types: H, HS, and HN

B3. Stainless Steel Ties

Underwriters Laboratories, Inc. Canadian Standards Association

File No. E147128

All types of wiring duct

C1. Wiring Duct

File No. 016446, 210335

CSA Standard C22.2 No.18.5-02 Positioning Devices.

All types of wiring duct

C2. Surface Raceway

C3. Abrasion Protection

Conformite European

2006/95/EEC

C4. Cable Management

ENC50085 cable trunking system and cable ducting systems for electrical installations CDS (cable ducting system) for impact 2 J Minimum storage and transport temperature -5C Wiring duct types: Minimum installation and application H, HS, G, F, D, MC, FS, temperature -5C NNC, TMC and NE Maximum application temperature 60C Non-flame propagating Without electrical continuity Cover removable without a tool

D1. Terminals

Logo (Symbol)

Agency

Complies with:

Requirement

Applicable Products

D2. Power Connectors

D3. Grounding Connectors

DIN (Deutsches Institut fur Normung), German DIN 43 659 Institute for Standardization

E1. Labeling Systems

This European standard specifies dimensions for slotted trunkings that will be used in electrical switchgear assemblies and that conform to the corresponding requirements in DIN VDE 060 Part 506. The dimensions specified Wiring duct types: with the standard include: MC, TMC and NNC The channel mounting hole pattern, slot dimensions, pitch and location The distance from the first to last like size mounting hole Minimum overall product length Nonmetallic ducts shall be permitted (inside enclosures) only when they are made with a flame retardant material. Flame-retardant material is defined in the standard by the IEC 60332-1 test method.

NFPA 79-2007, section 13.3.1


E2. Labels

Wiring duct types: H, G, F, D, MC, NNC, TMC and CWD

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

National Fire Protection Agency

NFPA 79-2007, section 13.5.2

PANDUIT wiring duct publishes a maximum percentage wirefill for common wire types equal to 50% of the interior cross-sectional area of the duct.

Wiring duct types: H, G, F, FS, D, MC, NNC and TMC

NFPA 79-2007, section 13.1.5.9

PANDUIT bend radius control accessories can be mounted at right angle and tee Duct corner strip with 1" junctions created using wiring duct in order bend radius control to maintain cable bend radius control.
Performance criteria for the Flammability and Smoke Emission Characteristics of Materials used in Fixed Guideway Vehicles and Passenger Rail Cars.

NFPA 130, 2007 edition, section 8.4.1

Type TMC wiring duct

C1.50

ELECTRICAL SOLUTIONS
PANDUIT Wiring Duct Approvals and Compliances (continued)
A. System Overview

B1. Cable Ties

Logo (Symbol)

Agency

Spec/Approval

Requirement

Applicable Products

Underwriters Laboratories, Inc.

UL 508, section 15

An insulating barrier (divider wall) shall be manufactured from an insulating material exhibiting minimum properties including High Current Arc Resistance to ignition PVC divider wall (HAI), Hot Wire Ignition (HWI), Comparative Tracking Index (CTI), electrical Relative Thermal Index (RTI) and flame class. Material is rated for a continuous use temperature above 167F (75C). Material contains no fluorine, bromide, or chlorine and will not emit any corrosive or toxic gases when burned, confirmed using IEC 60754-2 test method. Per UL standard, material is self-extinguishing and has excellent fire resistance. Per ASTM test method and NFPA 130 standard, material exceeds the requirements for low smoke generating material. Per the Boeing and Airbus test standards, material exceeds the requirements for low levels of toxic gas release. Wiring duct types: NE, NNC, and NNC

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

Elevated temperature

PANDUIT logo

Halogen-free IEC 60754-2

PANDUIT logo

Wiring duct types: NE and NNC

C2. Surface Raceway

Low flammability UL 94V-0

PANDUIT logo

Wiring duct types: NNC, TMC, and all PVC wiring duct

C3. Abrasion Protection

Low smoke ASTM E 662

PANDUIT logo

Wiring duct type: TMC

C4. Cable Management

Low toxicity Boeing and Airbus BSS-7239, ATS 1000.1

D1. Terminals

PANDUIT logo

Wiring duct types: NNC and TMC


D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

C1.51

ELECTRICAL SOLUTIONS
A. System Overview

B1. Cable Ties

NOTES

B2. Cable Accessories

B3. Stainless Steel Ties

C1. Wiring Duct

C2. Surface Raceway

C3. Abrasion Protection

C4. Cable Management

D1. Terminals

D2. Power Connectors

D3. Grounding Connectors

E1. Labeling Systems

E2. Labels

E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index

C1.52