Вы находитесь на странице: 1из 30

iPasolink 200

Digital Microwave Transmission System Fast Data Configuration Guide

NE Login
1. Connect the PC to the LCT port of IDU.

2. Set the IP address for PC as OBTAIN DSN SERVER ADDRESS AUTOMATICALLY

3. Input the IP address of the NE and WebLCT in URL Address box: http://172.17.254.253.The WebLCT login window appears, as shown

4. Input User Name: Admin, and Password: 12345678 in textbox. 5. Press OK. The WebLCT main window appears

Equipment Configuration
1. Expand Equipment Setup -> Equipment Configuration from the WebLCT menu. 2. Click the Setup.

3. Input the Equipment Name, then Next.

4. Set Modem1 as used, and then click Next.

5. Confirm that the setup parameter changes to blue, and then click OK

6. Click OK in the pop-up Warning box.

Radio Configuration
1. Expand Equipment Setup -> Radio Configuration from the WebLCT menu. 2. Click Setup. The Step1 Window appears

3. Input Channel Spacing /Modulation/TX frequency from Link Budget, Radio mode :High capacity, Frame ID :1, TX power control : MTPC. and then click Next button.

4. Confirm that the setup parameter and then click OK

5. Click OK in the pop-up Warning box

E1/ETH Capacity Setting


1. Expand Provisioning -> MODEM Function Setting-> AMR / Radio Mapping Configuration. 2. Input the E1 channels to be used, STM-1 must be 0, ETH bandwidth will be calculated automatically,

2. Input the E1 channels to be used, STM-1 must be 0, ETH bandwidth will be calculated automatically, and then click Next button.

3. Confirm that the setup parameter and then click OK

4. Click OK in the pop-up Warning box

Date / Time Setting


1. Expand Equipment Utility -> Date/Time Setting->Modify

2. Set the date and time for IDU.

TX Power Setting
1. Expand Provisioning -> MODEM Function Setting-> TX Power Setting

2. Click the MODEM1 to configure. The TX Power Setting dialog box appears.

3. Assign a proper value for each parameter. Then, click OK 4. Click OK in the pop-up Information box.

Network Setting- Set IP for IDU


1. Click the Maintenance button on the top of the LCT window to turn on the maintenance mode. 2. Expand Equipment Setup -> Network Management Configuration->General Setting 3. Click Setup button. The General Setting box appears

4. The default IP address is 172.18.0.1 for Near End site IDU, 172.18.0.2 for Far End site IDU.

E1 Port Setting
1. Expand Provisioning -> E1/STM-1/Cross Connect Setting -> E1 Port Setting 2. Click the Modify button. The E1 Port Setting (Main Board) dialog box appears 3. Assign

2. Click the Modify button. The E1 Port Setting (Main Board) dialog box appears

3. Assign a proper value for each parameter. Then, click OK 4. Click OK in the pop-up Information box

3 TDM setting:1 . Go to Easy Setup Wizard and Click TDM Setup

3. TDM setup: Click Enable E1 CH Usage and go to Add More XC

4. Write a name in service name and select Main Board at near end(E1/Modem) and MODEM1

at far end (MODEM) 5. OK

6 OK

7: complete ok

ETH Port Setting


1. Expand Provisioning-> ETH Function Setting -> ETH Port Setting

2. Click the desired Port No. to configure. The ETH Port Setting dialog box appear

3. Click OK in the pop-up Information box.

4.

VLAN Setting-Adding

1. Expand Provisioning -> ETH Function Setting ->VLAN Setting

Click VLAN List tab. The VALN List tab appears.

Click the Add VLAN ID button to create a new VLAN ID.

4: Click Add VLAN ID 3 times and add 3 ID 4080, 4081 and 4082 one by one

VLAN Setting-Setting
1. Expand Provisioning-> ETH Function Setting-> VLAN Setting 2. Click Port No. button. The VLAN Setting window appears

3 Make Port Type Trunk from Access and enable all VLAN ID and press OK

4. Click OK in the pop-up Information box.

5 VLAN setting Click Port1 of MODEM1

6 Enable All VLAN ID and press OK

7 OK

5.

RX level & alarm Check

1. Expand Metering-> Current Metering

2. Click MODEM1

3. Confirm the RX level is up to the design value, and the BER is better than 0.0E-8.

4. Expand Current Status-> Active alarm

5. Confirm no alarm such as: LOF, RX level, ODU alarms.

6.

Link Performance Check

7. 1. Expand Current/History PMON/RMON Report --> MODEM PMON Report

6. Click Modem1

3. Confirm the value of UAS,ES, SES are 0 in the past 30 minutes.

THE END THANKS MOVE ON TRAFFIC SHIFTING

Вам также может понравиться