Вы находитесь на странице: 1из 26

Quantium 200T

Description Models & Options

Introduction
Presentation of the Quantium 200T
Specifications
How to use this document
Models
Standard features
Options
Accessories
Dimension specification
Product option matrix

Description Models & Options

Quantium 200T
Description Models & Options
Contents
Introduction ............................................................................................................................................................................................ 7
Presentation of the Quantium 200T ..................................................................................................................................................... 7
Description .......................................................................................................................................................................................... 7
Best-in-industry components for unmatched ergonomics ........................................................................................................................ 7
Specifications ........................................................................................................................................................................................ 7
Approvals ............................................................................................................................................................................................ 7
Environmental conditions ...................................................................................................................................................................... 8
How to use this document ..................................................................................................................................................................... 8
Model identification .............................................................................................................................................................................. 8
Models and Options .............................................................................................................................................................................. 9
Symbols .............................................................................................................................................................................................. 9
Models .................................................................................................................................................................................................. 10
Model Q200T 1-1 ........................................................................................................................................................................ 10
Model Q200T 1-1m ..................................................................................................................................................................... 10
Model Q200T 1-2 ........................................................................................................................................................................ 10
Model Q200T 2-2 ........................................................................................................................................................................ 10
Model Q200T 2-2d ...................................................................................................................................................................... 10
Model Q200T 2-2m ..................................................................................................................................................................... 11
Model Q200T HD 1-1 .................................................................................................................................................................. 11
Model Q200T HD 1-1m ............................................................................................................................................................... 11
Model Q200T HD 2-2 .................................................................................................................................................................. 11
Model Q200T HD 2-2d ................................................................................................................................................................ 11
Model Q200T VHS 1-1 ................................................................................................................................................................ 11
Standard features ................................................................................................................................................................................ 12
Orientation ........................................................................................................................................................................................ 12
Pumping unit ...................................................................................................................................................................................... 12
Metering device ................................................................................................................................................................................. 12
Control valves .................................................................................................................................................................................... 12
Electronics ........................................................................................................................................................................................ 12
Display .............................................................................................................................................................................................. 12
Protocol ............................................................................................................................................................................................ 12
Frame and cladding ............................................................................................................................................................................. 13
Nozzle ............................................................................................................................................................................................... 13
Hose ................................................................................................................................................................................................. 13

Description Models & Options

Hose system ..................................................................................................................................................................................... 13


Nozzle boot ........................................................................................................................................................................................ 13
LPG .................................................................................................................................................................................................. 13
Power ............................................................................................................................................................................................... 13
Livery ................................................................................................................................................................................................ 13
Totalisers .......................................................................................................................................................................................... 14
Transport .......................................................................................................................................................................................... 14
Options ................................................................................................................................................................................................. 15
Tokheim ECVR-OL .............................................................................................................................................................................. 15
Tokheim ECVR OL deduction for diesel hoses ....................................................................................................................................... 15
GRVP ................................................................................................................................................................................................ 15
GRVP deduction for diesel hoses ......................................................................................................................................................... 15
Mechanical totalisers ......................................................................................................................................................................... 15
Mechanical totalisers combined ........................................................................................................................................................... 15
Mechanical totaliser readable from outside .......................................................................................................................................... 15
Preset valves .................................................................................................................................................................................... 16
Nozzle OPW ....................................................................................................................................................................................... 16
Nozzle OPW dripfree .......................................................................................................................................................................... 16
Nozzle ZVA with dripcatcher ............................................................................................................................................................... 16
Nozzle ZVA dripstop ........................................................................................................................................................................... 16
Colour splash guard ............................................................................................................................................................................ 16
Nozzle latch ....................................................................................................................................................................................... 16
Nozzle boot locks ............................................................................................................................................................................... 16
Nozzle-mounted sight glass ................................................................................................................................................................. 17
Nozzle-mounted breakaway coupling (non-VR and VR) ............................................................................................................................ 17
Goodyear hose ................................................................................................................................................................................... 17
Elaflex low temperature hose ............................................................................................................................................................. 17
No hose, no nozzle .............................................................................................................................................................................. 17
40/80 speed selection ........................................................................................................................................................................ 17
Hose 5.5 m ....................................................................................................................................................................................... 17
Air vent pipes to outside of frame ...................................................................................................................................................... 18
Filter with monitoring point ................................................................................................................................................................. 18
Flexible coupling 1.5 female thread ................................................................................................................................................... 18
Flexible coupling 1.5 O-ring compression flange ................................................................................................................................. 18
Submerged standard .......................................................................................................................................................................... 18
Submerged inlet shear valve OPW ....................................................................................................................................................... 18
Nefit adaptor ..................................................................................................................................................................................... 19
Single-phase motor ............................................................................................................................................................................. 19

Delta connection ................................................................................................................................................................................ 19


Second side display ............................................................................................................................................................................ 19
Preset keypad ................................................................................................................................................................................... 19
Spring mast ....................................................................................................................................................................................... 19
VR quick connection couplings ............................................................................................................................................................. 19
VR flame arrestor package ................................................................................................................................................................. 19
VR pressure monitoring point and gauge .............................................................................................................................................. 20
VR vacuum gauge visible ..................................................................................................................................................................... 20
VR safety shear valve ........................................................................................................................................................................ 20
Internal configuration keypad .............................................................................................................................................................. 20
Dispenser compatible with infrared remote control .............................................................................................................................. 20
LCD backlight .................................................................................................................................................................................... 20
Illuminated product indication .............................................................................................................................................................. 20
Emergency manual pumping device ...................................................................................................................................................... 21
Emergency manual pumping device and electrical reset combined .......................................................................................................... 21
Empty calculator housing .................................................................................................................................................................... 21
Heater in calculator housing ................................................................................................................................................................ 21
Electrical reset .................................................................................................................................................................................. 21
Empty tank contact ........................................................................................................................................................................... 21
Painted columns ................................................................................................................................................................................. 21
Painted head ...................................................................................................................................................................................... 22
Stainless steel hydraulic doors ............................................................................................................................................................ 22
Stainless steel electronic doors ........................................................................................................................................................... 22
Leak plate .......................................................................................................................................................................................... 22
Metax interface ................................................................................................................................................................................. 22
Dispenser W&M sealing - France ........................................................................................................................................................ 22
Dispenser W&M sealing - Italy ............................................................................................................................................................ 22
Accessories ........................................................................................................................................................................................... 23
Standard User Access Keypad (UAK) .................................................................................................................................................. 23
Ground frame .................................................................................................................................................................................... 23
Livery low cost .................................................................................................................................................................................. 23
Livery medium cost ............................................................................................................................................................................ 23
Livery high cost ................................................................................................................................................................................. 23
Reinforced packaging .......................................................................................................................................................................... 23
Export packaging ............................................................................................................................................................................... 23
Dimension specification ...................................................................................................................................................................... 24
Appendix: Product Option Matrix rev. 18 ........................................................................................................................................... 24

Description Models & Options

Document history
Date

Revision

Reference

Page

13 Sept 2002

01

Q200T-DMO-01-GB-0902

4 Nov 2002

02

Q200T-DMO-02-GB-1102

9
10-11
12
16 (15)
17 (16)
19 (18)
20 (19)
22 (21)

23 (22)
25 (24)
22 May 2003

03

Q200T-DMO-03-GB-0503

12
13
16
(17)

17
19
20
(21)
21
(21)

(22)
22

Subject
Creation
- Adjusted symbols
- Updated schematics
- Adjusted standard features according to POM rev. 15
- Deleted option: Nozzle Dayco
- Modified option: Goodyear hose
- Deleted option: Dayco hose
- Modified option: Spring mast
- Modified option: Illuminated product indication
- Modified option: Stainless steel columns -> Painted columns
- Modified option: Stainless steel head -> Painted head
- Modified option: Stainless steel hydraulic doors
- Modified option: Stainless steel electronic doors
- Removed Protocols
- Added remark in Accessories section
- Replaced POM rev. 12 by POM rev. 15
- Removed model: Q200T LPG 1-1
- Modified feature: Cladding and frame
- Modified option: Preset valves
- Removed options:
LPG nozzle Elaflex
LPG nozzle Nettuno
LPG nozzle LG30
- Added new option: Hose 5.5 m
- Added new option: Nefit adaptor
- Modified option: Preset keypad
- Added new option: Dispenser compatible with infrared remote control
- Removed option: Emergency manual pumping device battery backup
- Added option: Emergency manual pumping device and electrical reset
- Added new option: Heater in calculator housing
- Removed options:
LPG without nozzle boot
LPG emergency stop button
LPG shear valve for non chair
- Removed options:
Programming switch
LPG dry breakaway Batchen
- Added new option: Metax interface
- Added new option: Dispenser W&M sealing - France

In the above table, page numbers between brackets refer to page numbering in the previous revision.
This document contains 26 pages (including cover sheets).

Introduction
The purpose of this publication is to assist in the identification of the range of Quantium 200T models.
The basic information for the Quantium 200T and descriptions of the various available options are included.
This publication is part of a set of documents specifically produced for the Quantium 200T range. For further technical
information, please refer to the relevant associated publication.

Presentation of the Quantium 200T


Description
The Quantium200T is a range of low-end single and twin dispensers only available as retail models.
All models are island-oriented. They can be single- and double-sided. Single- sided models have the hose at the right hand
side when looking at the A-side of the dispenser.
The A-side of the dispenser has the inlet connections and electrical connections (mains junction box if present), and is
the programming side of the dispenser.

Best-in-industry components for unmatched ergonomics


Built using proven components, the Quantium 200T is an industry reference in terms of ergonomics and performance.
The EPZ pump and the MA 26 meter device are twinned with the WWC T1 calculator at the heart of the configuration,
making Quantium 200T the most reliable and best-performing dispenser in its category.

Specifications
Approvals
All models will require both safety and weights and measures approvals in each country in which they will be marketed.
The major, specific approvals to be included initially include the following:
NMI (Dutch Weights and Measures) Certification to OIML standards and EMC verification.
TV (Germany) Safety certification
SIRA (UK) Certification to CEN
Above safety certificates to be used as a basis to gain safety certification and approvals for all other intended market
countries.

Description Models & Options

Local / country specific W&M, additional safety, and VR approvals have to be secured before sales are commenced.
All CE Directives (Machinery, EMC and eventually ATEX) also have to be in place and handled by engineering and the
factory during the design phase.

Environmental conditions
Ambient temperature:

-25C to +55C for the standard model

Temperature of fluid:

-25c to +25C

Viscosity of fluid:

< 10-4 m/s

Relative humidity:

5% to 95% non-condensing

Climate:

Marine, tropical, industrial and polar

Altitude:

from sea level to 2000 m

How to use this document


Model identification
On the following pages, a code is used to identify the model. This code is explained below.
The first number in the Tokheim code used in the matrices relates to the number of products.
The second number relates to the number of hoses.
The m at the end means that the dispenser has a mechanical register.
The d at the end means that the dispenser has 4 displays (2-2 only has 2 displays).
The following identifications of "speed" are used to qualify the nominal flow rates at which products are delivered by
the dispensers:
StdS means Standard Speed, a nominal flow rate of 40 l/min. for VR and 50 l/min. for non-VR,
HD means High Delivery, a nominal flow rate of 80 l/min.,
VHS means Very High Speed, a nominal flow rate of 130 l/min.

Models and Options


Models and Options are displayed in a matrix which presents standard models in a line and available options in a column.
A grey box indicates that the corresponding line option is not available on the corresponding column model. The
Quantium 200T matrix is presented as an appendix to the present document.

Symbols

Meter

EPZ pump

PAS V3 pump

Display WWC

Display mechanical
register

Display Cecli2

Slave display

Volume only display

Nozzle boot + lpm

LPG meter + valve

LPG air separator

Solenoid valve

Description Models & Options

Models
Model Q200T 1-1

Single-product, one-hose metering pump/dis-

50

penser.

StdS.

Model Q200T 1-1m

Single-product, one-hose metering pump/dis-

50

penser with mechanical register.

StdS.

Model Q200T 1-2

Single-product, two-hose metering pump/dispenser.

50

50

50

50

50

50

StdS.
Flow rate reduces to approximately 35 l/min. per
hose with both nozzles dispensing.

Model Q200T 2-2

Two-product, two-hose metering pump/dispenser.

StdS.

Model Q200T 2-2d

Two-product, two-hose metering pump/dispenser


with 2 displays (1 per side).

StdS.

10

Model Q200T 2-2m

Two-product, two-hose metering pump/dispenser with mechanical register.

50

50

StdS.

Model Q200T HD 1-1

Single-product, one-hose metering pump/dis-

80

penser.

HD.

Model Q200T HD 1-1m

Single-product, one-hose metering pump/dis-

80

penser with mechanical register.

HD.

Model Q200T HD 2-2

Two-product, two-hose metering pump/dis-

80

80

80

80

penser.

HD.

Model Q200T HD 2-2d

Two-product, two-hose metering pump/dispenser with 2 displays (1 per side).

HD.

Model Q200T VHS 1-1

Single-product, one-hose metering pump/dis-

130

penser.

VHS.

11

Description Models & Options

Standard features
Orientation
Island-oriented with hose connection ready to take hose.
Hook hose system big enough to hold two loops (either next or on top of each other).

Pumping unit
EPZ pumping unit for standard speed (StdS) and high-speed (HS) delivery with integrated filter (70 micron plastic
re-usable) and built-in foot valve (check valve).

PASV3 for very high speed (VHS) diesel with external vertical filter box (90 micron plastic re-usable) and built-in
foot valve (check valve).

Metering device
MA 26 mechanically calibrated 4-pistons meter with integrated MP T1 pulser for electronic dispensers.
LPG meter for LPG dispensers.

Control valves
Inline valves, 24V, allowing two-stage configuration for preset applications.

Electronics
WWC T1 calculator with liquid crystal displays for Money (1), Volume (1) and Grade Price (1/2).
Veeder Root VR10 mechanical register with mechanical reset (model with m suffix).

Display
LCD displays with WWC T1.

Protocol
IFSF Tokheim EPS ZSR Dunclare 82D EIN (JKR) M3000 Logitron Tatsuno Autotank Kienzle.

12

Frame and cladding


Galvanised steel for internal bracketing.
Stainless steel for outer frame (hydraulic cabinet and electronic head).
Powder-painted electronic and hydraulic doors.

Nozzle
ZVA.
Boessenkool (LPG).

Hose
Elaflex 3.8 m (black).
LPG hose.

Hose system
Hook.

Nozzle boot
Plastic Quantium T nozzle boot (black).

LPG
Deadmans button.
Elaflex brake.

Power
Three-phase +N, AC 50 Hz, 10 A, 400/230 V, +/-10%.

Livery
Not part of the standard configuration and always has to be selected as an option (see Options).

13

Description Models & Options

Totalisers
None for electrical.
Standard for mechanical register.

Transport
Pallet.

14

Options
Tokheim ECVR-OL
Tokheim open loop vapour recovery system with ZVA nozzle, Elaflex hose, Asco control valve, Drr vacuum pump
and one return line per dispenser.

Tokheim ECVR OL deduction for diesel hoses


With a combined diesel gasoline dispenser this option has to be selected otherwise costs for VR hoses will be
charged.

GRVP
Mechanically controlled Elaflex GRVP vapour recovery system with ZVA nozzle, Elaflex hose, Drr vacuum pump,
one return line per dispenser (with single dispensers this automatically is VR return line per product).

GRVP deduction for diesel hoses


With a combined diesel gasoline dispenser this option has to be selected otherwise costs for VR hoses will be
charged.

Mechanical totalisers
Driven by meter and mounted directly on meter.
Easily readable by only opening one door / panel.

Mechanical totalisers combined


For configurations with two meters delivering one product (very high speed). For taxation reasons.
Used in Italy.

Mechanical totaliser readable from outside


MOC requirement in South Africa.

15

Description Models & Options

Preset valves
These valves differ from normal stop-valves in that they can control the speed of the fuel flow in more than one
ratio.

They enable the slower filling up of the tank that is needed where of a preset option has been selected on the
dispenser, via the forecourt controller or a payment terminal.

The preset valve will be available for every fuel grade type (for LPG it can only be driven remotely by POS), every
flow rate and every hydraulic frame position.

Nozzle OPW
OPW nozzle (non-VR version) instead of ZVA.

Nozzle OPW dripfree


OPW nozzle (non-VR version) with similar function to ZVA with drip catcher.

Nozzle ZVA with dripcatcher


ZVA nozzle with a ring on the nozzle spout, which prevents drips from soiling the nozzle (used on diesel nozzles).

Nozzle ZVA dripstop


ZVA nozzle with a special device that prevents from drips.

Colour splash guard


Splash guard to be added to ZVA nozzles.

Nozzle latch
Latching device allowing the nozzle trigger to be blocked in delivering position without having to keep it pressed.

Nozzle boot locks


A lock that enables owner to lock the nozzle to its boot when the forecourt is closed.

16

Nozzle-mounted sight glass


A sight glass inserted between nozzle and hose.

Nozzle-mounted breakaway coupling (non-VR and VR)


This is a coupling that will prevent spillage if the hose and the nozzle are forced apart in such a way as to cause
leakage (e.g., a drive-off with the nozzle still inserted in the car tank opening).

It should be noted that breakaway couplings restrict the flow rate to a certain degree.

Goodyear hose
As an alternative to standard Elaflex hose.
Not available for VR.

Elaflex low temperature hose


Hoses whose material quality is suitable for usage in a low temperature environment.
Not available for LPG.

No hose, no nozzle
For export markets where hoses and nozzles from local suppliers are used.
Dispenser does not have CE sticker and type plates.

40/80 speed selection


Available on all HS dispensers except for cc models.
For the HS diesel nozzles, the standard flow rate is 40 l/min. A push button enables to select a higher flow rate for
trucks, 80 l/min.

Hose 5.5 m
Goodyear hose 5.5 m, alternative to standard hose.

17

Description Models & Options

Air vent pipes to outside of frame


A pipe between the pumping unit vent and the outside of the frame with a defined outlet for the evacuation of any
liquid ejected through the vent.

Used in Italy.

Filter with monitoring point


Each filter pot is fitted with a small ball valve with a threaded connection which can be used to introduce air into
the pump inlet. There is also a check valve mounted between the ball valve and the filter pot (to prevent liquid
escape from the filter pot).

This option is needed because in some countries the metrology state officer has to be able to check without the use
of any tools that the dispenser switches off when air enters the system.

Mandatory in Austria.

Flexible coupling 1.5 female thread


Flexible metal connector from filter pot of the pumping unit to a female 1.5 thread accepting a 1.5 BSP pipe that
comes from underground to feed the dispenser.

Hydraulic inlet option for PASV3.

Flexible coupling 1.5 O-ring compression flange


Flexible metal connector from filter pot of the pumping unit to a female 1.5 O-ring compression flange set
accepting an unthreaded 1.5 pipe that comes from underground to feed the dispenser.

Hydraulic inlet option for PASV3.

Submerged standard
Built-in hydraulic pumping units are replaced by connection to standard submerged pumps.

Submerged inlet shear valve OPW


A shear valve located between dispenser inlet and ground connection.
In case the dispenser is hit and forced of its island, the shear valve will close to prevent the pressurized submerge
system to spill its fuel to the environment.

18

Nefit adaptor
Used in Spain.

Single-phase motor
An alternative 230V, 50 Hz motor.
Mainly used in the UK and Africa.

Delta connection
A connection in delta instead of star configuration for three-phase motors.
Mainly used in Belgium.

Second side display


Standard dispenser only has one display. For double-sided use a display should be added to the other side of the
dispenser.

Preset keypad
Kaypad that allows the customer to choose a preset amount of money or fuel.
Once a selection is made, the dispenser automatically delivers the right amount (via the electronics and the abovementioned preset keypad).

Preset valves are included in this option (see above).

Spring mast
Alternative to the standard hook system for a more user-friendly storage of the hose (actual hose length: 4.2 m).

VR quick connection couplings


Quick connection couplings, instead of standard threads, to easily connect/disconnect the VR return line to the
underground piping.

VR flame arrestor package


A flame arrestor inserted at the VR outlet.
19

Description Models & Options

This is mandatory in certain countries and requested by some customers in other ones.

VR pressure monitoring point and gauge


An additional connection fitted with a gauge used to monitor the pressure of the VR system return line.

VR vacuum gauge visible


A vacuum type gauge, visible from the outside, positioned between the vacuum pumps and the proportional valves
to monitor function of VR system.

As per Italian regulations.

VR safety shear valve


A shear valve located between dispenser VR return pipe and ground connection.
To be supplied separate from dispenser.

Internal configuration keypad


A simple configuration keypad that is permanently stored inside the calculator head.
See WWC T1 Setup and Maintenance Manual.

Dispenser compatible with infrared remote control


The dispenser is delivered with a calculator that can be programmed via a remote control.
This infra red remote control is not an option for the dispenser and must be ordered separately.

LCD backlight
To improve readability of the display when it is dark (preferably using a single light bulb).

Illuminated product indication


The product identification panels located in the electronic head are separately illuminated.
This option automatically comes with LCD backlight.

20

Emergency manual pumping device


In case of long mains interruption, it is possible to operate the dispenser with a hand krank.
The models with electronic calculator are fitted with a high-capacity battery.
The models with mechanical register have a manual reset.

Emergency manual pumping device and electrical reset combined


When combining the option emergency manual pumping device with electrical reset on models with mechanical
register, an emergency reset handle is added to the configuration. This way the dispenser can be kept operational
during a power failure.

Mainly for Africa.

Empty calculator housing


To fit third party calculator. Product liability is with third party.
Empty means there is no calculator and no display but cabling and glands for following functions should be available:
motors (with thermal protection in head cables are routed into the head anyway), power supply (glands), valves and
pulsers.

Mainly for Germany, Denmark, Spain and Austria.

Heater in calculator housing


For low temperature markets, to prevent the LCD display from freezing.

Electrical reset
To replace the standard manual reset on mechanical register.

Empty tank contact


A signal send to the dispenser when the main storage tank is empty putting the dispenser on hold. When picking
up the nozzle no delivery is possible. Only with WWC T1 calculator. Uses IEB board.

Mandatory in Italy.

Painted columns
Hydraulic columns (side panels) painted.
21

Description Models & Options

Painted head
Calculator head painted.

Stainless steel hydraulic doors


Hydraulic doors in mirror finished stainless steel.
By selecting this option and/or the Stainless steel electronic door option, no livery option has to be selected, i.e.
the price of the stainless steel hydraulic doors includes the painted electronic doors.

Stainless steel electronic doors


Electronic doors in mirror finished stainless steel.
By selecting this option and/or the Stainless steel hydraulic door option, no livery option has to be selected, i.e.
the price of the stainless steel hydraulic doors includes the painted electronic doors.

Leak plate
A plate mounted in the dispenser to prevent fuel leaking into the ground.

Metax interface
Only available with Tatsuno protocol.
Used in Scandinavia.

Dispenser W&M sealing - France


Additional type plates per product.
Mandatory in France.

Dispenser W&M sealing - Italy


Seals all connections/joints in the fuel line after the meter.
Mandatory in Italy.

22

Livery low cost


Single colour for the complete dispenser.

Livery medium cost


Two colours on the dispenser or one colour and single-colour logo.

Livery high cost


Three colours or more (including colours on logos, if required).

Reinforced packaging
For shipments where the material suffers from additional load (for instance when multiple transport companies are
used.

Export packaging
Wooden crate for shipments to export markets.

Accessories
Standard User Access Keypad (UAK)
For programming by service engineer.

Ground frame
A frame that will be fixed in the concrete island-foundation of the dispenser. It should allow the throughput of all
piping, cabling, etc. and the fixation of the main mechanical parts like hydraulic frames, columns, shear valves etc.
to the ground.

Please note that Accesoories have to be ordered from the Spare Parts Centres and not the Manufacturing Centres.

23

Description Models & Options

Dimension specification

24

TOKHEIM Quantium 200T POM

/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/hose
/pump
/pump
/pump
/pump
/pump
/pump
/pump
/pump
/pump
/side
/side
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp
/disp

Code
Left&Right versions
Products
Pumps
Rate (lpm)
Hoses
Displays

OPTIONAL FEATURES
Tokheim ECVR OL
Tokheim ECVR OL deduction diesel hoses
GRVP
GRVP deduction diesel hoses
Mechanical totalizer
Mechanical totalizers combined (I)
Mechanical totalizer readable from outside (SA)
Preset valves
Nozzle OPW
Nozzle OPW dripfree
Nozzle ZVA with dripcatcher
Nozzle ZVA dripstop
Colour splash guard ZVA
Nozzle latch
Nozzle boots lock
Nozzle mounted sightglass
Nozzle-mounted breakaway coupling
Nozzle-mounted breakaway coupling VR
Goodyear hose
Elaflex low temperature hose
No hose, no nozzle
Hose 5,5m
40/80lpm speed selection
Air vent pipes to outside of frame
Filter with monitoring point (AT)
Flexible coupling 1.5" female thread
Flexible coupling 1.5" compression flange
Submerged standard
Submerged inlet shear valve OPW
Nefit adaptor
Single phase motor
Delta connection
Second side display
Preset keypad (including preset valves)
Spring mast (hose 4.2m)
VR quick connection coupling
VR flame arrestor package
VR pressure monitoring point and gauge (AT)
VR vacuum gauge visible (I)
VR safety shear valve
Internal configuration keypad
Dispenser compatible with infra red control
LCD backlight
Illuminated product indication
Emergency manual pumping device (=EMPD)
EMPD and electrical reset combined
Empty calculator housing
Heater in calculator housing
Electrical reset
Empty tank contact (I)
Painted columns
Painted head
Stainless steel hydraulic doors
Stainless steel electronic doors
Leak plate
Metax interface
Dispenser W&M sealing France
Dispenser W&M sealing Italy
Livery low cost
Livery medium cost
Livery high cost
Reinforced packaging
Export packaging (wooden crate)

STANDARD VERSIONS

Factory: Grentheville
POM version: rev18

HD 1-1
no
1 (diesel)
1
80
1
1

HD 1-1m
no
1 (diesel)
1
80
1
2 (VR10)

HD 2-2
no
1 (diesel)
2
80
2
4

Calculator: WWCT1
VR10 mechanical register
LCD with WWC-T1
IFSF/Tokheim/EPS/ZSR/DUN
82D/EIN/M3000/Logitron/Tatsuno
Autotank/Kienzle

Display:
Protocol:

1-1
1-1m
1-2
2-2
2-2d
2-2m
no
no
no
no
no
no
1
1
1
2
2
2
1
1
1
2
2
2
50(VR-40)
50
50(VR-40) 50(VR-40) 50(VR-40)
50
1
1
2
2
2
2
1
2 (VR10)
2
4
2
4 (VR10)

Standard configuration:
Orientation: Island
Pumps:
Rotary vane type EPZ for SS/HD
Gear type PASV3 for VHS diesel
Meter:
Piston type MA26
Ctrl valves: Inline, preset ready
HD 2-2d
no
1 (diesel)
2
80
2
2

VHS 1-1
no
1 (diesel)
1
130
1
1

Cladding: Stainless steel frame, powder painted doors


Nozzle:
ZVA
Hose:
Elaflex 3.8m (black)
Hose systemHook
Nozzle boot Plastic QT (black)
LPG:

3 phase + N, AC 50 Hz
10 A, 400/230 V, +/-10%
None
None for electrical
In mechanical register
Transport: Pallet

Livery:
Totaliser:

Power:

Tokheim
DIRECT OPERATIONS
A

Austria
Tokheim
Eitzenberger strae 4-6
A-2544 Leobersdorf
+43 (0) 2256 606 0
+43 (0) 2256 606 170

Belgium
Tokheim
Everdongenlaan 31
2300 Turnhout
+32 (0) 14 44 85 00
+32 (0) 14 44 85 55

CZ

Czech Republic
Tokheim
Pernerova 48
CZ - 186 02 Prague 8
+420 2 24890312
+420 2 232 72 67

NL

France
Tokheim (Corporate headquarters)
ZAC Paris Nord 2
B.P. 40027
95912 Roissy C.D.G. Cedex
+33 (0)1 49 90 77 00
+33 (0)1 49 90 77 77
France
Tokheim Services France
9, avenue Galile
92350 Le Plessis Robinson
+33 (0)1 41 36 13 00
+33 (0)1 41 36 13 70
Germany
Tokheim GmbH
Lothstrasse 1a
D-80335 Mnchen
+49 (0)89 18953-0
+49 (0)89 18953-399
Italy
Tokheim Sofitam
Quattordio KM 10800
S.P. 26
14030 Scurzolengo (AT)
+39 0141 2038200
+39 0141 2038222
Netherlands
Tokheim
Touwslagerstraat 17
Postbus 4186
2980 GD Ridderkerk
+31 180 481500
+31 180 481555

RFC Cameroon

Socatam
B.P. 3941
Douala
+237 40 57 86
+237 40 57 88
MA

Morocco
Matam
209, bd. Moulay Ismail
Route de Rabat
Casablanca
+212 22 40 40 24
+212 22 40 40 21

Portugal
G.N.C.
Parque de ciencia e Tecnologia
Edificio Tecnologia I, N 27
2780 Oeiras
Lisboa
+351 (0)1 422 04 20
+351 (0)1 421 42 26

SN

Senegal
Cosetam
Quartier de Bel Air
Route des Hydrocarbures
BP 1237
Dakar
+221 832 23 71
+221 832 68 34

RUS

Russia
Tokheim Representative Office
Roome 380 - Hotel Ukraina
Kutuzovski prospekt, 2/1, stroyenie 1
Moscow, 121249 Russia
+7 (095) 933 69 35
+7 (095) 933 69 34

ZA

South Africa
Tokheim
Stand 110 Precision Road
Kya Sand, Randburg
+27 11 4622105
+27 11 4621942

TN
SK

Slovak Republic
Tokheim
Mlynske Nivy 70
SK- 82015 Bratislava
+421 7 58270215
+421 7 53414123

Tunisia
Cottam
116, av. de lUnion
du Maghreb Arabe
B.P. 117
La Soukra
2036 Tunis
+216 1 759 550
+216 1 765 943

PL

Poland
Pol-Germann Tokheim
UL Narwicka 1
80557 Gdansk
+48 58 343 21 71
+48 58 343 22 15

DK Denmark & Scandinavia

Tokheim
Hejrevang 10
3450 Allerd
+45 48 14 14 00
+45 48 17 45 96

Norway
Tokheim
Verkseier Furulunds vei 11B
P.O. Box 45 - Alnabru
0614 Oslo
+47 22 90 49 50
+47 22 90 49 51

CH

GB

Spain
Koppens Iberica
Calle Imprenta 5
Poligono industrial de Alcobendas
28100 Alcobendas (Madrid)
+34 91 661 28 13
+34 91 661 41 30
Switzerland
Tokheim
Route du Crochet 7
Case postale 50
1762 Givisiez
+41 (0)26 460 51 11
+41 (0)26 460 51 12
United Kingdom
Tokheim
Unit 3 Baker Road
West Pitkero Industrial Estate
Dundee DD5 3RT
+44 (0)1382 598000
+44 (0)1382 598001

MIDDLE EAST, SOUTH CENTRAL


AMERICA, AFRICA
Tokheim
ZAC Paris Nord 2
B.P. 40027
95912 Roissy C.D.G. Cedex
France
+33 (0)1 49 90 77 56 - 77 31
+33 (0)1 49 90 77 93
ASIA
Tokheim
POBOX # 16869
JAFZ
Dubai UAE
+971 4 881 3305
+971 4 881 4463

As Tokheim regularly improves its products to ever better


respond to evolving market and regulatory requirements, it
reserves the right to change any of the specifications of these
products, and this without prior notice.