Вы находитесь на странице: 1из 7

RESUME

Personal details

Objective

Name E-mail Mob no Nationality Sex

: S.Arunkumar : sarunkvp@gmail.com :+919698638080 : Indian : Male

Seeking a challenging position in an environment that encourages being innovative, enterprising and to apply my technical skills and abilities in an industry that offers career & professional growth and to contribute effectively to the growth of the organization

Professional Details Professional Qualification: B.E(Electrical & Electronics)

Marital Status: Single


Experience : 4+

Years IN

Languages Known: English, French ,Hindi and Tamil

VOLTECH ENGINEERS PVT LTD, CHENNAI.

Skill Set Passport Details: Passport No. : CBEA00687110 Place of Issue : Coimbatore Date of Issue : 14.08.2008 Date of Expiry : 13.08.2018 Address: 7/29,koonavelampatti, Rasipuram, Namakkal(D.T), Tamil Nadu,India. Having an experience and knowledge in Testing, Commissioning and Maintenance of power plant, substation and process plant.

Page 1 of 7

Nature of work Testing and commissioning of all Electrical equipment from 415 volts to 765 KV System. Inspection of control and relay panel, preparation of Test Report and cable schedule for sub-station, and process plant. Testing and commissioning of control & relay panel for Transformer, Bus Coupler, BusTransfer, and Line feeder. Testing and commissioning of power control centre and motor control centre. Testing of Protective Relays for various needs, Experience with relays. Over current and earth fault relays Knowledge of Transformer protection, Transformer Differential Protection & REF Protection, Motor protection Testing of CT, P.T., CVT, Circuit breaker, switch gear and Power Transformer Operation and Maintenance of Power Plant and sub-station. Trouble shooting of all Electrical circuits, control and protection circuits Co-ordination with client in As Built Scheme drawing submission, test report submission,

Experience with AREVA RELAYS Omicron 256 Doble Experience with AREVA RELAYS SKD, SKE Check Syn Relay P-632,P-111,P-143 differential,O/C,E/F,REF, SEF Relay NEUTRAL DISPLCEMENT Relay VAA Under Voltage Relay VAGM Relay VTX Relay

Experience with SIEMENS Relays 7SJ600 O/C & E/F Relay 7SJ61 O/C & E/F Relay 7SJ62 Directional O/C Relay 7UT60 REF PROT relay 7UT61 Numerical Differential Protection Relay, Experience with ABB Relays

SPAM 150C Motor protection relay SPAJ 140c relay REF 610 REF relay REM 543 Motor protection relay

Experience with SEL Relays SEL-751A,SEL-710 Feeder Protection Relay

Page 2 of 7

Projects Handled in varies places in India,

Through Project Client


Duration

: : :
:

IOTEP 6.6/.415 KV HT LT S/S,NAPATHA CRACKER PROJECT


INDIAN OIL CORPARATION LTD,panipat.Haryana 6 months

Executed activities LIKE

CT & PT Precommissioning Checks Local/Remote & Logical Interlock Scheme Checks, Electro Mechanical interlocks, Electrical Interlock check. VCB Precommissioning Checks(Timing,Contact Resistonce,Electrical&Mechanical Operation Checks) HT-CABLE TEST(IR Value & HI-POT TEST) TRANSFORMER Precommissioning Checks and Done the commissioning Testing of protective relays( O/C , E/F & Differential) Done the commissioning of HT-LT Substations

Through Project Client


Duration

: : :
:

VASAVI POWER SERVICEs LTD 2X125MW SURAT THERMAL POWER PLANT


GUJARAT INDUSTRIES POWER CORPARATION LTD,Nani Naroli,Gujarat. 12 months

Executed activities LIKE Scheme Checking & Testing of Unit Protection of Generator,Transformers and Motors CT,PT& VCB Precommissioning Checks HT-CABLE Testing 10.5/220kV and UNIT TRANSFORMER Precommissioning Checks and Done the commissioning Testing of protective relays( O/C , E/F & Differential) Done the commissioning of Power plant and HT-LT Substations.

Page 3 of 7

Through Project Client


Duration

: : :
:

ABB LTD 220KV SWITCH YARD, ANJAR,GUJARAT


GUJARAT ENERGY TRANSMISSION CORPARATION LTD,Anjar. 6 months

Executed activities LIKE Testing & commissioning of 220 KV Switch yard, Control & Protection Scheme checking & Testing of protective relays. Local / Remote operations of Circuit Breakers and Isolators. CB Timing tested Electrical Interlock check Distance protection checking E/Sw Close/open operation check Testing of protective relays( Directional O/C & E/F). : : :
:

Through Project Client


Duration

L&T LTD 33/11/6.6/.415KV HT LT S/S, BARMER OIL PLANT,Rajasthan. CAIRN ENERGY INDIA LTD.
6 months

Executed activities LIKE Preparing the As Built documentations and Red Mark drawings CT,PT& VCB Precommissioning Checks HT-CABLE Testing 33/11/6.6/.415KV TRANSFORMERS Precommissioning Checks and Done the commissioning Testing of protective relays( O/C , E/F & Differential) : : :
:

Through Project Clint


Duration

LINDE ENGINEERING INDIA LTD 6.6/.415KV HT LT S/S,HYDROGEN GENERATION PLANT


INDIAN OIL CORPARATION LTD,Barauni,Bihar. 4 months

Executed activities LIKE Testing and commissioning of all kind of Protective relays like O/C, E/F, O/V, U/V, Differential prot. Relays Trouble Shooting during Commissioning CT,PT&VCB Precommissioning Checks Transformer REF scheme and all functional checking L.T and H.T motors Testing and Commissioning HT-CABLE Testing

Page 4 of 7

Through Project Client


Duration

: : :
:

HINDUSTHAN ZINC LTD, 33/.415KV HT LT S/S,PANTNAGAR SILVER PLANT HINDUSTHAN ZINC LTD,Pantnagar,Uttarkhand
3 months

Executed activities LIKE CT & PT Precommissioning Checks OLTC and RTCC operation checking with AVR. Transformer REF scheme and all functional checking 33/.415KV Transformer and panel Commissioning Testing of protective relays

Through Project Client


Duration

: : :
:

A2Z LTD, 220/132/33KV switchyard,JATH,MAHARASTRA MSTECL.


3 months

Executed activities LIKE CT & PT Precommissioning Checks Transformer REF scheme and all functional checking Distance protection checking Testing of protective relays : : :
:

Through Project Client


Duration

Mukand Engineers Ltd 2 X 600MW LANCO ANPARAThermal Power Plant , ANPARA LANCO INFRATECH LTD.
8 months

Executed activities LIKE 22/11KV 2 nos of UNIT TRANSFORMER Precommissioning Checks and Done the commissioning 22/3.3KV 2 nos of UNIT AUXILARY TRANSFORMER Precommissioning Checks and Done the commissioning FAST AND SLOW CHANGE OVER of 11KV panel 765KV shunt reactor differential stability Auto change over of 2 Incomers and 1 Buscoupler in 3.3kv panel switchboard 11/3.3KV Transformers Testing and REF,SEFand Differential stablities 11/.415 Transformers Testing and REF,SEF stablities 11,3.3,.415KV Motor testing and stablities 11,3.3,.415KV panel equipments Testing and commissioning Done synchronization and commissioning of the 2*600MW power plant. Page 5 of 7

Project Client
Duration

: :
:

1 X 12MW Agarwal sponge & Energy pvt ltd,Bellary SIEMENS LTD.


3 months

Generator testing and its differerential stability LAVT, NGR Panel testing GRP,Syncronization panel testing AVR panel testing CTS,PTS testing AOP,EOP,JOP Motors testing Done synchronization and commissioning of the 12MW power plant.

Project Client
Duration

: :
:

765/400KV Switch yard PGGIL,Orisa SIEMENS LTD.


1 months

Testing & commissioning of 220 KV Switch yard, Control & Protection Scheme checking & Testing of protective relays. Local / Remote operations of Circuit Breakers and Isolators. CB Timing tested Electrical Interlock check Distance protection checking E/Sw Close/open operation check Testing of protective relays( Directional O/C & E/F).

Declaration

I hereby declare that, the above-furnished information is true to the best of my knowledge.

Yours Faithfully, S.Arunkumar

Page 6 of 7

Page 7 of 7

Вам также может понравиться