Technical Data Sheet for AvK-Alternators

Date: Project No.: Object data: Site: Application: Generator data: Generator: Rated power: Power factor: Power at pf 1,0 Rated voltage: Speed: Frequency: Rated current: Winding pitch: Insulation class: Ambient temperature: Site altitude: Enclosure: Cooling: Coolant: 04/05/2012 P-2012-hf195-10000006/1DE

FM 7.3-5

Customer: Bitte Interessent eingeben! AvK Reference: 1-416-0000006-1 Prime Mover: Manufacturer: 4 1705 kWm 1705 kWm Diesel engine

Stationary Power Plant DIG 120 k/4 Poles: 2050 kVA 1640 kWe 0.80 1654 kVA 1654 kWe 3.3 kV 1500 1/min 50 Hz 358.7 A ca. 5/6 Stator: Class F Rotor: Class F 40 C 1000 m IP23 IC 01 - Open-circuit ventilation Ambient Air Temperature Coolant: Cooling air vol.: 66 kgm Weight:

Standards: IEC 60034

Voltage range / frequency range: Zone A according IEC 60034-1 (dU = +/-5%, df = +/-2%) Temperature rise: Standard environment F

Environment: Filter: 40 C 2.5 m /s 6000 Kg

Moment of inertia (I):

Temperature Air inlet generator: Cooling water quantity: Losses (environment): Losses (cooling):

40 C n/a 65 KW n/a

Wires: Operation mode: Regulators: Voltage regulator: Electrical data: Efficiencies: Power factor 0.8 Power factor 0.9 Power factor 1.0

4 terminals, starpoint connected in terminal box Island mode with identical generators in parallel DECS 100 (acc. IEC) 110% 96,01 96,43 96,85 100% 96,2 96,6 97 75% 96,1 96,4 96,7 50% 95,4 95,7 96 25% 92,6 92,8 93

Reactances and time constants


unsaturated saturated unsaturated saturated

xd 2.30 2.07 p.u. xd' 0.270 0.270 p.u. xd'' 0.187 0.170 p.u. x2 0.197 0.179 p.u. x1s n.a. 0.102 p.u. Short circuit ratio saturated: 0.48 Short circuit data: Initial short circuit current (3-phase): Max. peak current (3-phase): Sustained short circuit current: Initial short circuit torque: Max. faulty synchron moment: Rated kVA torque: Rated torque Shaft torque

xq xq' xq'' x0

1.15 1.15 0.187 0.056

1.13 1.13 0.187 0.051

p.u. p.u. p.u. p.u.

Td0' Td' Td'' Ta

3.2 0.38 0.015 0.05

s s s s

Td0'' Tq0' Tq0'' Tq' Tq''

0.02382 0.3 0.18449 0.3 0.03

s s s s s

Zn 5.312 Ohm

Ik'' IS Ik Mk2 Mk3 Mf MSN MN MSh

2110 A 5371 A 1076 A 99.8 kNm 59.9 kNm 214.6 kNm 13.05 kNm 10.44 kNm 10.85 kNm

3 x rated current for max.10 s

Load application: max. load application: 1139 kVA(corresponds to 55,56 % von 2050 kVA) for Power factor 0.4 15% transient voltage drop Remarks:

Power: 2050 kVA Power factor: 0.8 transient voltage drop: -21.3 %

Order specification for AvK-Alternators -technical-

FM 7.2-4

Projekt checklist
Issued by: Created by: Released by: Date: Sales department Jerry Yu (hf195) QuotationTool 04/05/12

CGT Order No.:


1 Spare parts order no.: Others:

Customer:
Revision no.: Revision date: 2 3 Application / Project: CGT quotation no.:

Bitte Interessent eingeben!


1 04/05/12 Alternator type: 1-416-0000006-1 P-2012-hf195-10000006/1 DE Quantity: DIG 120 k/4 1

4 5 6 7.1 7.2 7.3 17 18 19 20 21 22 23 24 27 28 29 30 31 32 33 34 35 36 37 53 54 55 57 59 62 63 64 65 70 71 72 73

Factory Project no.: Customer Order no.: Delivery Date: Order Type: Reference: Valid drawing at order entry:

Mode of operation:

Stationary Power Plant

Rated data
Output: P.F. Cos Phi: Voltage: Current: Frequency: Speed: 2050 kVA 0.80 3.3 kV 358.7 A 50 Hz 1500 1/min

Rules, Standards
Standards: R.I.S. Degree: Insulation class: Temperature rise: Ambient temperature: Altitude at site: IEC 60034 VDE 0875 N Class F F 40 C 1000 m

Technical data
Efficiency: Rated load at cos phi = 0.8: Rated load at cos phi = 1: Efficiency tolerance: Reactances, time constants: Overspeed: Operating voltage range: Operating frequency range: Parallel operation: Overload capability: 3-phas. sustained short circuit current: Design details, general Design form: AvK project drawing: Center height: Type of prime mover / Manufacturer and name of prime mover: Shaft end / -flange (DE): Rotation facing DE: Surface treatment: Dynamic balancing: Enclosure, Cooler Enclosure alternator: Enclosure terminal box: Cooling type: IP23 IP54 IC 01 - Open-circuit ventilation
Revision: J dated 17.09.2004 Cummins Generator Technologies Germany GmbH

see technical data sheet attached 96.20 97.00 acc. to VDE 0530, EN 60034 see technical data sheet attached 1,2 x rated speed for 2 min Zone A according IEC 60034-1 (dU = +/-5%, df = +/-2%) +/- 10% at no load for synchronisation, short term operation only view line 33 Island mode with identical generators in parallel 10 % for 1 h every 12 hours or 50 % for 30 sec. 3 x rated current for max. 10 sec.

IMB3 / IM 100x 630 mm Diesel engine /

IM 1001

cylindrical shaft end clockwise Standard primer with half key at shaft end

Document: 7_2f04jE.xls 2/3

Order specification for AvK-Alternators -technical-

FM 7.2-4

77 98

Coolant: Bearing arrangement + Lubrication

Ambient Air

99 Bearing Design: 100 Calculated Lifetime: 101 Protection against shaft currents: 116 Terminal box + Accessories, Current transformers 117 119 121 122 Location main terminal box (seen on DE): Cable entry: Cable gland plate: Details, quantity + diameter of cables:

Anti-Friction bearing about 30.000 operating hours Not insulated,

Standard terminal box top Undrilled gland plate aluminium Each phase: Cable qty. unknown; Type unknown; ODM unknown N point: Cable qty. unknown; Type unknown; ODM unknown 4 terminals, starpoint connected in terminal box

123 Star point arrangement: 141 Voltage regulation system 142 Voltage regulator:

DECS 100 Regulator function(s): VAR regulation Voltage matching Overexcitation limiter Underexcitation limiter Black Start Capability PMG

148 Power supply of voltage regulator:: 149 Regulator location: 154 Instrumentation 155 156 157 159 162 Temperature detection stator windings: Bearing temperature detection NDE-side: Bearing temperature detection DE-side: PT 100 design / connection: Anti-condensation heater built-in:

6 PT100 Single PT100 Single PT100 Standard design in 2-wire connection Supply voltage 230 V, 1-phase, 50/60 Hz, AC/DC Power required 500 W

168 Works Tests 169 CGT Test:

first generator: Repeat Test acc. to AvK Specification ING-PS-0005; all other generators (if applicable): not applicable not applicable

170 Additional tests: 171 Works test witnessed by client: 174 Documentation / Dates: 175 177 178 179 180 171 183 Dimensional drawing: Shaft drawing with moment of inertia: Connection/terminal plan: Drawings as DXF-File Operating instructions, Spare part lists: Test reports and Certificates: Number copies and language of documentation:

ca. 4 weeks after placement of order ca. 4 weeks after placement of order ca. 6 weeks after placement of order No 2 weeks after works test 2 weeks after works test 3 x English

202 Additional details 203 Voltage matching: For Decs 100 and 200 the ratio of the sensing VTs for generator and busbar voltage can be different.

Document: 7_2f04jE.xls 3/3

Revision: J dated 17.09.2004 Cummins Generator Technologies Germany GmbH