Вы находитесь на странице: 1из 8

Solved with COMSOL Multiphysics 4.

3a

Transient Response of a Biased R e s o n a t o r 2 D


Introduction
Silicon micromechanical resonators have long been used for designing sensors and are now becoming increasingly important as oscillators in the consumer electronics market. In this sequence of models, a surface micromachined MEMS resonator, designed as part of a micromechanical filter, is analyzed in detail. The resonator is based on that developed in Ref. 1. This model performs a transient analysis of the response of the structure when a step function is applied to the resonator. The analysis begins from the stationary analysis performed in the accompanying model Stationary Analysis of a Biased Resonator 2D; please review this model first.

Model Definition
The geometry, fabrication, and operation of the device are discussed in Stationary Analysis of a Biased Resonator2D. This model performs a time domain analysis on the structure, when the applied bias of 35 V is switched on. The transition time of the step is 0.5 s. Since the response of the system is required, damping must be added to the model. For this study it is assumed that the damping mechanism is Rayleigh damping or material damping. This damping model is discussed in more detail in the accompanying frequency-domain analysis: biased_resonator_freq.mph. The damping factors used in the model are: dM = 4189 Hz and dK = 8.291013 s, consistent with the observed quality factor of 8000 for the fundamental mode.

Results and Discussion


The bias voltage applied to the device is shown in Figure 1 and its amplitude response is shown in Figure 2.

2012 COMSOL

1 |

TR A N S I E N T R E S P O N S E O F A B I A S E D R E S O N A T O R 2 D

Solved with COMSOL Multiphysics 4.3a

Figure 1: Step function bias applied to the drive electrode.

Figure 2: Time domain response of the device.

2 |

TR A N S I E N T R E S P O N S E O F A B I A S E D R E S O N A T O R 2 D 2 0 1 2 C O M S O L

Solved with COMSOL Multiphysics 4.3a

Figure 2 shows that the position of the actuator initially follows the drive voltage, changing on a similar time scale. After the voltage stops changing, the displacement oscillates about the DC steady state deflection, close to 12.6 nm (this is in agreement with the stationary study with the same applied voltage). The oscillation is clearly under damped and the amplitude does not decrease significantly on the time scale that the model was run for. With such a large quality factor resonator a large number of cycles would need to be solved for to see the decay of the oscillation. Given the small time span of the solution, it is difficult to estimate the frequency of the resonance accurately, however, the period is approximately 0.13 s which is close to the period of the fundamental, which at this bias is 0.124 s.

Reference
1. F.D. Bannon III, J.R. Clark and C.T.-C. Nguyen, High-Q HF Microelectromechanical Filters, IEEE Journal of Solid State Circuits, vol. 35, no. 4, pp. 512526, 2000.

Model Library path: MEMS_Module/Actuators/


biased_resonator_2d_transient

Modeling Instructions
Open the existing stationary study (filename: biased_resonator_2d_basic.mph).
1 From the View menu, choose Model Library. 2 Go to the Model Library window. 3 In the Model Library tree, select MEMS Module>Actuators>biased resonator 2d basic. 4 Click Open. 5 Click the Zoom Extents button on the Graphics toolbar.

Create parameters for the material damping factors.


GLOBAL DEFINITIONS

Parameters
1 In the Model Builder window, expand the Global Definitions node, then click Parameters.

2012 COMSOL

3 |

TR A N S I E N T R E S P O N S E O F A B I A S E D R E S O N A T O R 2 D

Solved with COMSOL Multiphysics 4.3a

2 In the Parameters settings window, locate the Parameters section. 3 In the table, enter the following settings:
NAME EXPRESSION DESCRIPTION

alpha beta

4189 [Hz] 8.29e-13[s]

Damping parameter - alpha Damping parameter - beta

Add damping to the physics settings.


MODEL 1

In the Model Builder window, expand the Model 1 node.


ELECTROMECHANICS

Linear Elastic Dielectric 1


In the Model Builder window, expand the Model 1>Electromechanics node.

Damping 1
1 Right-click Linear Elastic Dielectric 1 and choose Damping. 2 In the Damping settings window, locate the Damping Settings section. 3 In the dM edit field, type alpha. 4 In the dK edit field, type beta.

Define the step function bias.


DEFINITIONS

Step 1
1 In the Model Builder window, under Model 1 right-click Definitions and choose Functions>Step. 2 In the Step settings window, locate the Function Name section. 3 In the Function name edit field, type Vapp. 4 Locate the Parameters section. In the Location edit field, type 3e-7. 5 In the To edit field, type Vdc. 6 Click to expand the Smoothing section. In the Size of transition zone edit field, type
5e-7.

7 Click the Create Plot button.

4 |

TR A N S I E N T R E S P O N S E O F A B I A S E D R E S O N A T O R 2 D 2 0 1 2 C O M S O L

Solved with COMSOL Multiphysics 4.3a

RESULTS

Data Sets
1 In the Model Builder window, expand the Results>Data Sets node, then click Function 1D 1. 2 In the Function 1D settings window, locate the Parameter Bounds section. 3 In the Maximum edit field, type 12E-7. 4 In the Minimum edit field, type 0.

1D Plot Group 4
1 In the Model Builder window, under Results click 1D Plot Group 4. 2 In the 1D Plot Group settings window, locate the Plot Settings section. 3 Select the x-axis label check box. 4 In the associated edit field, type Time (s). 5 Select the y-axis label check box. 6 In the associated edit field, type Bias Voltage (V). 7 Right-click Results>1D Plot Group 4 and choose Rename. 8 Go to the Rename 1D Plot Group dialog box and type Applied Voltage Step in

the New name edit field.


9 Click OK.

This plot shows the form of the applied voltage. Compare with Figure 1. Set the applied voltage to the defined step function.
ELECTROMECHANICS

Electric Potential 3
1 In the Electric Potential settings window, locate the Electric Potential section. 2 In the V0 edit field, type Vapp(t/1[s]).

Create an integration operator to track the displacement of the mid point of the beam with time.
DEFINITIONS

Integration 1
1 In the Model Builder window, under Model 1 right-click Definitions and choose Model Couplings>Integration. 2 In the Integration settings window, locate the Source Selection section.

2012 COMSOL

5 |

TR A N S I E N T R E S P O N S E O F A B I A S E D R E S O N A T O R 2 D

Solved with COMSOL Multiphysics 4.3a

3 From the Geometric entity level list, choose Point. 4 Select Point 38 only. 5 Locate the Advanced section. From the Frame list, choose Material (X, Y, Z).

Create a probe to store the displacement at all the time steps computed by the solver.
6 In the Model Builder window, under Model 1>Definitions click Global Variable Probe 1. 7 In the Global Variable Probe settings window, locate the Expression section. 8 In the Expression edit field, type intop1(v).

Add a transient study to the model.


ROOT

In the Model Builder window, right-click the root node and choose Add Study.
MODEL WIZARD

1 Go to the Model Wizard window. 2 Find the Studies subsection. In the tree, select Preset Studies>Time Dependent. 3 Click Finish.
STUDY 2

Step 1: Time Dependent


1 In the Model Builder window, right-click Study 2 and choose Rename. 2 Go to the Rename Study dialog box and type Transient in the New name edit field. 3 Click OK.
TR A N S I E N T

Step 1: Time Dependent


1 In the Time Dependent settings window, locate the Study Settings section. 2 In the Times edit field, type range(0,1.2e-7,12e-7).

Change the relative tolerance to reduce the solver steps.


3 Select the Relative tolerance check box. 4 In the associated edit field, type 1e-5.

Turn off the default plots.


5 In the Model Builder window, click Transient. 6 In the Study settings window, locate the Study Settings section.

6 |

TR A N S I E N T R E S P O N S E O F A B I A S E D R E S O N A T O R 2 D 2 0 1 2 C O M S O L

Solved with COMSOL Multiphysics 4.3a

7 Clear the Generate default plots check box.

Scale the dependent variables appropriately to reflect the small length scales in the problem.

Solver 2
1 Right-click Transient and choose Show Default Solver. 2 In the Model Builder window, expand the Solver 2 node. 3 In the Model Builder window, expand the Transient>Solver Configurations>Solver 2>Dependent Variables 1 node, then click mod1.u. 4 In the Field settings window, locate the Scaling section. 5 From the Method list, choose Manual. 6 In the Scale edit field, type 1e-6. 7 In the Model Builder window, under Transient>Solver Configurations>Solver 2>Dependent Variables 1 click mod1.xy. 8 In the Field settings window, locate the Scaling section. 9 From the Method list, choose Manual. 1 0 In the Scale edit field, type 1e-6.

Change the absolute tolerance to a value less than the relative tolerance.
1 1 In the Model Builder window, under Transient>Solver Configurations>Solver 2 click Time-Dependent Solver 1. 1 2 In the Time-Dependent Solver settings window, click to expand the Absolute Tolerance

section.
1 3 In the Tolerance edit field, type 1e-6.

Set the maximum solver time step to ensure that the frequency of interest is resolved.
1 4 Click to expand the Time Stepping section. From the Method list, choose Generalized alpha. 1 5 Select the Maximum step check box. 1 6 In the associated edit field, type 0.2e-7. 1 7 In the Model Builder window, right-click Transient and choose Compute.

Create a plot to show the displacement of the mid point of the resonator as a function of time.

2012 COMSOL

7 |

TR A N S I E N T R E S P O N S E O F A B I A S E D R E S O N A T O R 2 D

Solved with COMSOL Multiphysics 4.3a

RESULTS

1D Plot Group 6
1 In the Model Builder window, right-click Results and choose 1D Plot Group. 2 In the 1D Plot Group settings window, locate the Data section. 3 From the Data set list, choose None. 4 Locate the Plot Settings section. Select the x-axis label check box. 5 In the associated edit field, type Time (s). 6 Select the y-axis label check box. 7 In the associated edit field, type Midpoint Displacement (um). 8 Right-click Results>1D Plot Group 6 and choose Table Graph. 9 Right-click 1D Plot Group 6 and choose Rename. 10 Go to the Rename 1D Plot Group dialog box and type Transient Point
Displacement in the New name edit field.

11 Click OK. 12 Right-click 1D Plot Group 6 and choose Plot.

Compare this plot with Figure 2.

8 |

TR A N S I E N T R E S P O N S E O F A B I A S E D R E S O N A T O R 2 D 2 0 1 2 C O M S O L

Вам также может понравиться