ZY-260
Automatic Clinical Chemistry Analyzer
(Up to 200 tests/hour, 450 tests/hour with ISE) A compact complete chemistry analysis system Proven reliability and low maintenance High-precision micro-sampling Auto-dilution function and auto-probe cleaning 12 wavelengths coving all range of bio-chemical test More accurate test results with KHB reagent

Shanghai Kehua Laboratory System Co., Ltd.

ZY-260 Specification
Throughput Characteristics Up to 200 chemistry test/hour, 450 test/hour with ISE Fully open system, support domestic and imported reagent. System Function 24-hour continuous operation, STAT tests, automatic pre-dilution, re-measurement, sleeping and awaking. Double reagent, double wavelength, random set-up of reaction time from 1 to 15 minutes Clinical biochemical, immunological therapeutic drug monitoring Serum, plasma, urine, cerebrospinal fluid. One-and, two-point, end-point, kinetic, fixed time, one-point, end-point+front section measurement, two-point end-point+front section+front measurement. Linear calibration: K factor, two-and multi-point linear. Nonlinear calibration: spline, broken line, polynomial, logarithm, Logit-Log 3P, Logit-Log 4P, Logit-log 5P, etc perspective turbidimetry,

Test range Sample type Test method

Calibration

Sample System
Sample tray Sample volume Sample position & Reagent positions are designed with three circles. Total 54 positions available. 2.550l0.1l increment

High-precision polished probes Sample probe Liquid level sensor, Volume tracking, Solid collision protection and probe block detector etc. Automatic solid vertical wash technology, contamination rate <0.08% Sample tube Micro tube, original blood-gathering tube and plastic tube etc.

Reagent system
Reagent tray Reagent volume Sample position & Reagent positions are designed with three circles. Total 72 positions available. Free setting for detergent 20350l0.5l increment High-precision polished probes Reagent probe Liquid level sensor, Volume tracking, Solid collision protection and probe block detector etc. Automatic solid vertical wash technology, contamination rate <0.08% Reagent preservation Cleaning system Reaction tray Cuvettes Reaction volume Constant temperature system Reaction tray temperature Mixing facility 28independent power supply on 24 hour continuous refrigeration

Cleaning system
Auto 7-steps cleaning, support both Acid and alkaline detergent.

Reaction system
Wheel, 81 cuvettes Imported Permanent quartz cuvette (optical diameter:6mm) 150500l Long live simultaneous constant temperature system 370.1, real time temperature display Independent mixing stick, Nanotechnology based highly polished and automatic frequency change

Optical system
Lamp Spectrophotometric Method Wavelength Wavelength precision Absorbance linearity Resolution Stray light Software Display Print function Port High-quality halogen lamp with adjustable luminosity, life-span over 2500 hours Rear spectrometer technology with holography flat-field concave grating and transient detecting system with photoelectric diode 12 wavelength340380405450505546578600660 700750800 nm <1nm -0.3~4.0Abs 0.0001 <0.1% or Abs>3.0

Data management
V2.0 LED display Report format and non-report format TCP/IPRS-232Cs standard port

Options
ISE Internal barcode reader Power supply Power Fuse Temperature Water consumption Dimension Weight Operation system CPU Memory Hardware Display Port Printer Na , K , Cl For reagent
+ + -

Working condition
~220V22V50Hz1Hz 900VA (UPS1500VA) ~250V/F6.25A 15302 Deionized water <3L/Hour 960mmL 600mmW 500mmH 100kg

PC (optional)
Windows2000, XP, Win7 Intel PIII-800 or above 256M 20G 15 inch, Resolution1024 768 TCP/IP,RS-232C,USB1.1, parallel port 9 or 24 pin

ISE Module reference parameters


Electrodes reference parameters Electrode K
+ +

Test range/(mmol/L) 0.50-20.00 15.0-200.0 15.0-200.0

Resolution 0.01 0.1 0.1

Slope range/mV 40-70 40-70 40-70

Na Cl

SHANGHAI KEHUA LABORATORY SYSTEM CO., LTD.

Website:

www.skhb.com

Bldg 84, 1198 North Qianzhou Road, Shanghai 200233, China Tel: +86-21-6485 2180 E-mail: khbmarketing@khbls.com Fax: +86-21-6485 2182 Attn: International Marketing Department