Академический Документы
Профессиональный Документы
Культура Документы
30RB060-390
Air-Cooled Chillers
Product
Data
The AquaSnap chiller is an effective allin-one package that is easy to install and
easy to own. AquaSnap chillers cost less
to purchase and install, and then operate
quietly and efficiently. Value-added features include:
Rotary scroll compression
Puron HFC refrigerant (R-410A)
Quiet AeroAcoustic fan system
Easy to use ComfortLink controls
Optional full heat reclaim package
Optional integrated hydronic pump
package, available with variable
frequency drive (VFD)
Novation heat exchanger technology
with microchannel coil
Features/Benefits
Carriers superior chiller
design provides savings at
initial purchase, at installation, and for years afterward.
a30-3922
a30-4007
SEISMICOMPLIANT*
* Meets IBC 2006, ASCE-7-05, CBC 2007, and OSHPD seismic requirements.
Carrier Corporation 2013
Form 30RB-17PD
Features/Benefits (cont)
AquaSnap chillers make
noise in the marketplace, not
the workplace
The AquaSnap chillers AeroAcoustic fan is almost twice as quiet as the
competitions per cfm. Much of the
noise reduction is in frequencies where
noise is most annoying, which makes
AquaSnap chillers ideal for soundsensitive environments. When lower
ambient temperatures allow part load
operation or during scheduled nighttime operation, the units operate with
fewer fans and become even quieter.
AquaSnap chillers are quiet during the
day and even quieter at night.
All-in-one package
AquaSnap chillers provide the most
comprehensive chilled water circuit
available for any air-cooled chiller.
Included is a shell-in-tube
direct expansion cooler that may be
2
Environmentally sound
Carriers Puron refrigerant (R-410A)
enables you to make a responsible decision in the protection of the earths
ozone layer. Puron refrigerant is an
HFC refrigerant that does not contain
chlorine that is damaging to the ozone
layer. Puron refrigerant is unaffected
by the Montreal Protocol. Puron refrigerant is a safe, non-toxic, efficient and
environmentally sound refrigerant for
the future.
Structurally sound
The base rail is industrial-quality 7 ga
for maximum structural integrity. The
zinc-dipped galvanized frame (with SermaGuard coated screws) provides
the best protection on the market for
corrosion resistance. With such a structurally sound base, no perimeter base
rail is needed.
Com
The coil is designed with rubber isolation around the powder painted coil
frame to eliminate galvanic couples
which can cause corrosion due to dissimilar metals.
fortL
ink
MODE
Run Status
Service Test
MOD
E
Alarm
Run
Status
Servic
e Tes
t
perat
ures
Pressu
res
Setpo
ints
Temperature
Status
Pressures
Tem
Setpoints
Inputs
Inputs
Outpu
ts
Config
uration
Time
Clock
Opera
ting
Mode
Alarm
s
s
Alarm Status
Outputs
Configuration
ESC
Time Clock
Operating Modes
ENTE
R
Alarms
ESCAPE
ENTER
a30-2187
NAVIGATOR DISPLAY
TUBES
FINS
MANIFOLD
a30-3925
MICROCHANNELS
NOVATION
Table of contents
Page
Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
Model Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4,5
AHRI Capacity Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-15
Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-18
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19-37
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38-53
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54-58
Typical Piping and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59-63
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64-72
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73-75
Typical Control Wiring Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . .76,77
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78-85
Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86-92
0
1
2
3
4
5
F
G
H
J
K
M
N
P
T
Q
R
-
0
4
5
G
H
K
L
R
S
CRN
EMM
GFI-CO
LON
SCCR
VFD
XL
3
4
5
6
No Packaging
Skid
Skid, Top Crate, Bag
Coil Trim Panels
Skid, Coil Trim Panels
Skid, Top Crate, Bag, Coil Trim Panels
Coil Trim Panels, Upper and Lower Grilles
Skid, Coil Trim Panels, Upper and Lower Grilles
Skid, Top Crate, Bag, Coil Trim Panels, Upper and Lower Grilles
Trim Panels, Upper and Lower Grilles, Upper Hail Guards
Skid, Coil Trim Panels, Upper Grilles and Lower Grilles, Upper Hail Guards
Skid, Top Crate, Bag, Trim Panels, Upper and Lower Grilles, Upper Hail Guards
Skid, Full End Covers
Skid, Top Crate, Bag, Full End Covers
Full End Covers
BACnet Communication
BACnet Communication, EMM
BACnet Communication, Remote Service Port, GFI-CO
BACnet Communication, EMM, Remote Service Port, GFI-CO
LEGEND
Canadian Registration Number
Energy Management Module
Ground Fault Interrupting Convenience Outlet
Local Operating Network
Short Circuit Current Rating
Variable Frequency Device
Across-the-Line Start
L
0
1
3
4
5
7
8
9
C
D
F
H
J
K
Quality Assurance
Certified to ISO 9001
a30-5584
NOMINAL
TONS
60
70
80
90
100
110
120
130
150
160
170
NOMINAL
MODULE A
kW
210
245
280
315
350
385
421
456
526
562
597
MODULE B
UNIT 30RB
190
210
225
250
275
300
315
330
345
360
390
NOMINAL
TONS
190
210
225
250
275
300
315
330
345
360
390
NOMINAL
kW
667
737
791
879
967
1055
1107
1160
1213
1266
1370
MODULE A
MODULE B
160
170
170
190
190
160
160
170
170
190
CAPACITY
Tons
57.1
66.5
76.0
86.4
95.7
105.5
118.4
127.3
144.4
153.0
166.4
188.5
201.9
214.2
237.8
260.2
282.6
306.0
319.4
332.9
355.0
377.0
kW
200.8
233.9
267.3
303.8
336.5
371.0
416.4
447.7
507.8
538.0
585.5
662.9
710.0
753.3
836.2
915.0
993.8
1076.1
1123.6
1170.7
1248.4
1325.8
COMP
FAN
kW
60.1
73.1
85.0
91.1
104.0
116.6
129.5
137.5
158.4
162.8
182.4
205.6
217.6
236.8
261.5
284.0
308.1
325.7
345.2
364.8
388.0
411.1
kW
10.3
10.3
10.3
15.5
15.5
15.5
18.1
20.6
20.6
25.8
25.8
31.0
31.0
31.0
36.1
41.3
46.5
51.6
51.6
51.6
56.8
62.0
TOTAL
POWER
kW
70.4
83.4
95.3
106.6
119.5
132.1
147.6
158.1
179.0
188.6
208.2
236.6
248.6
267.8
297.6
325.3
354.6
377.3
396.8
416.4
444.8
473.1
FULL LOAD
EER
9.7
9.6
9.6
9.7
9.6
9.6
9.6
9.7
9.7
9.7
9.6
9.6
9.7
9.6
9.6
9.6
9.6
9.7
9.6
9.6
9.6
9.6
COP
2.9
2.8
2.8
2.9
2.8
2.8
2.8
2.8
2.8
2.9
2.8
2.8
2.9
2.8
2.8
2.8
2.8
2.9
2.8
2.8
2.8
2.8
IPLV
EER
13.1
13.4
14.2
13.4
13.6
13.7
13.7
13.6
13.8
13.4
13.5
13.4
13.7
13.8
13.6
13.7
13.5
13.4
13.5
13.5
13.5
13.4
COP
3.9
3.9
4.2
3.9
4.0
4.0
4.0
4.0
4.0
3.9
4.0
3.9
4.0
4.0
4.0
4.0
4.0
3.9
4.0
4.0
4.0
3.9
COOLER FLOW
RATE
GPM
L/s
136.5
8.6
159.0
10.0
181.7
11.5
206.7
13.0
229.0
14.4
252.1
15.9
283.2
17.9
304.4
19.2
345.3
21.8
366.0
23.1
398.1
25.1
450.9
28.4
482.7
30.5
512.3
32.3
568.8
35.9
622.4
39.3
675.6
42.6
731.9
46.2
764.1
48.2
796.3
50.2
849.0
53.6
901.7
56.9
COOLER PD
ft wg
8.9
11.7
7.0
8.9
10.7
8.8
10.9
12.5
7.5
8.4
9.8
12.4
9.9
11.2
13.6
16.2
19.0
8.4
9.8
9.8
12.4
12.4
kPa
26.6
35.0
20.9
26.6
32.0
26.3
32.6
37.4
22.4
25.1
29.3
37.1
29.6
33.5
40.7
48.4
56.8
25.1
29.3
29.3
37.1
37.1
LEGEND
Coefficient of Performance
Energy Efficiency Ratios
Integrated Part Load Value
Pressure Drop
Physical data
30RB060-300 ENGLISH
UNIT 30RB
OPERATING WEIGHT (lb)*
Al-Cu Condenser Coil
Cu-Cu Condenser Coil
MCHX Condenser Coil
REFRIGERANT TYPE
Refrigerant Charge (lb)
Std Coil, Ckt A/Ckt B/Ckt C
MCHX Coil, Ckt A/Ckt B/Ckt C
COMPRESSORS
Quantity
Speed (rpm)
(Qty) Compressor Model Number Ckt A
(Qty) Compressor Model Number Ckt B
(Qty) Compressor Model Number Ckt C
Oil Charge (Pt, Ckt A/Ckt B/Ckt C)
No. Capacity Steps
Standard
Optional (Maximum)
Minimum Capacity Step (%)
Standard
Optional
Capacity (%)
Ckt A
Ckt B
Ckt C
COOLER
Weight (empty, lb)
Net Fluid Volume (gal)
Maximum Refrigerant Pressure (psig)
Maximum Water-Side Pressure
without Pumps (psig)
Maximum Water-Side Pressure
with Pumps (psig)
COOLER WATER CONNECTIONS (in.)
Inlet and Outlet, Victaulic
Drain (NPT)
CONDENSER FANS
Standard Low Noise Type
Fan Speed (rpm) Standard
No. Blades...Diameter (in.)
No. Fans (Ckt A/Ckt B/Ckt C)
Total Airflow (cfm)
CONDENSER COILS
No. Coils (Ckt A/Ckt B/Ckt C)
Total Face Area (sq ft)
Max Working Refrigerant Pressure (psig)
OPTIONAL HEAT RECOVERY CONDENSER
Weight (lb) (empty)
Net Fluid Volume (gal)
Maximum Refrigerant Pressure (psig)
Maximum Water-Side Pressure (psig)
Water Connections (in.)
Inlet and Outlet, Victaulic
Drain (NPT)
HYDRONIC MODULE (Optional)
Pump
CHASSIS DIMENSIONS (ft-in.)
Length
Width
Height
Al-Cu
Cu-Cu
EXV
MCHX
N/A
070
080
4,111
4,593
3,783
4,317
4,799
3,978
4,600
5,082
4,267
090
100
110
5,932
6,155
6,519
6,656
6,879
7,243
5,449
5,663
6,027
R-410A, EXV Controlled System
120
130
150
7,690
8,534
7,119
8,045
9,010
7,402
9,174
10,139
8,517
94/96/
94/106/
94/133/ 133/106/ 133/133/
40/42/
40/53/
43/57/
54/43/
56/62/
Scroll, Hermetic
3
3
4
4
4
5
5
6
6
3500
(2) SH240 (2) SH300 (2) SH240 (2) SH300 (2) SH300 (2) SH300 (2) SH300 (3) SH300 (3) SH300
(1) SH240 (1) SH240 (2) SH240 (2) SH240 (2) SH300 (3) SH240 (3) SH300 (3) SH240 (3) SH300
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
26.2/13.1/ 29.2/13.1/ 26.2/26.2/ 29.2/26.2/ 29.2/29.2/ 29.2/39.4/ 29.2/43.8/ 43.8/39.4/ 43.8/43.8/
94/76/
40/40/
3
4
3
4
4
5
4
5
4
5
5
6
5
6
6
7
6
7
33
22
29
19
25
16
22
14
25
18
18
12
20
14
15
10
17
12
67
33
N/A
71
29
N/A
50
50
N/A
40
60
N/A
56
44
N/A
50
50
N/A
715
28.2
445
715
28.2
445
856
31.3
445
970
45.8
445
970
45.8
445
1518
73.5
445
300
300
300
300
300
300
300
300
300
150
150
150
150
150
150
150
150
150
56
50
45
44
50
55
N/A
N/A
N/A
Direct Expansion, Shell and Tube Type
856
856
970
31.3
31.3
45.8
445
445
445
3/
3/
3/
3/
3/
4
3/
4
3/
4
3/
4
3/
4
1140
930
3/1/
49,600
1140
930
2/2/
49,600
1140
930
3/3/
74,400
1140
930
3/3/
74,400
1140
930
3/4/
86,800
1140
930
4/4/
99,200
1140
930
4/4/
99,200
3/1/
94
656
3/1/
94
656
2/2/
94
656
3/4/
164
656
4/4/
188
656
4/4/
188
656
753
8.0
656
300
753
8.0
656
300
753
8.0
656
300
3/3/
3/3/
3/3/
141
141
141
656
656
656
Flooded, Shell and Tube Type
872
872
872
10.0
10.0
10.0
656
656
656
300
300
300
1236
15.1
656
300
1236
15.1
656
300
1236
15.1
656
300
1140
930
3/3/
74,400
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
LEGEND
Aluminum Fin/Copper Tube Condenser Coil
Copper Fin/Copper Tube Condenser Coil
Electronic Expansion Valve
Microchannel Condenser Coil
Not Applicable
060
11-10
7-425/32
7-67/16
15-9
160
170
190
210
225
250
10,266
11,472
9,475
10,601
11,807
9,799
12,013
13,460
11,064
162/106/
83/55/
162/130/
83/64/
162/162/
83/87/
7
8
7
8
8
9
9
10
9
10
10
11
11
12
12
13
13
8
14
10
13
9
10
6
11
8
10
7
9
7
8
6
62
38
N/A
57
43
N/A
50
50
N/A
36
36
28
33
33
33
1518
73.5
445
1518
73.5
445
1518
73.5
445
2382
86.6
445
2382
86.6
445
300
300
300
300
300
300
300
300
150
150
150
150
150
150
150
150
13,734
14,067
15,468
15,181
15,514
17,157
12,772
13,093
14,349
R-410A, EXV Controlled System
275
300
16,915
18,845
15,647
18,306
20,477
16,893
36
33
30
28
33
30
36
33
40
Direct Expansion, Shell and Tube Type
2382
2382
2382
86.6
86.6
86.6
445
445
445
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
1140
930
4/4/6
173,600
1140
930
6/6/4
198,400
1140
930
6/6/6
223,200
4/4/6
328
656
6/6/4
375
656
6/6/6
422
656
31-5
35-4
1140
930
6/4/
124,000
1140
930
6/6/
148,800
6/4/
235
656
6/4/
235
656
6/6/
282
656
1296
17.4
656
300
1296
17.4
656
300
1296
17.4
656
300
3/
8
3/
3/
8
1140
930
4/4/4
148,800
1140
930
4/4/4
148,800
4/4/4
4/4/4
282
282
656
656
Flooded, Shell and Tube Type
Not available
23-7
27-6
7-425/32
7-67/16
LEGEND
Aluminum Fin/Copper Tube Condenser Coil
Copper Fin/Copper Tube Condenser Coil
Electronic Expansion Valve
Microchannel Condenser Coil
Not Applicable
070
080
090
100
110
120
130
150
1869
2088
1716
1962
2181
1804
2091
2310
1934
2697
2798
2963
3026
3127
3292
2472
2569
2734
R-410A, EXV Controlled System
3488
3871
3229
3649
4087
3358
4161
4599
3863
3
4
4
5
4
5
4
5
5
6
5
6
6
7
6
7
33
22
29
19
25
16
22
14
25
18
18
12
20
14
15
10
17
12
67
33
N/A
71
29
N/A
50
50
N/A
40
60
N/A
56
44
N/A
50
50
N/A
324
106
3068
324
106
3068
388
118
3068
440
173
3068
440
173
3068
689
278
3068
2068
2068
2068
2068
2068
2068
2068
2068
2068
1034
1034
1034
1034
1034
1034
1034
1034
1034
56
50
45
44
50
55
N/A
N/A
N/A
Direct Expansion, Shell and Tube Type
388
388
440
118
118
173
3068
3068
3068
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
19
9762
3/1/
23 409
19
9762
2/2/
23 409
19
9762
3/3/
35 113
19
9762
3/3/
35 113
19
9762
3/3/
35 113
19
9762
3/4/
40 965
19
9762
4/4/
46 817
19
9762
4/4/
46 817
3/1/
8.73
3/1/
8.73
2/2/
8.73
3/3/
13.1
3/3/
13.1
3/3/
13.1
3/4/
15.24
4/4/
17.47
4/4/
17.47
4522
4522
4522
4522
4522
4522
4522
4522
4522
342
30.3
4523
2068
342
30.3
4523
2068
342
30.3
4523
2068
396
37.9
4523
2068
562
57.2
4523
2068
562
57.2
4523
2068
562
57.2
4523
2068
396
37.9
4523
2068
3/
8
3/
8
3/
8
3/
8
3/
3/
3/
8
3/
8
3/
8
LEGEND
Aluminum Fin/Copper Tube Condenser Coil
Copper Fin/Copper Tube Condenser Coil
Electronic Expansion Valve
Microchannel Condenser Coil
Not Applicable
060
3606
2255
2296.9
4800
30RB060-300 SI (cont)
UNIT 30RB
160
170
190
210
225
250
275
300
4666
5215
4297
4819
5367
4443
5461
6118
5019
6243
6901
5793
6394
7052
5937
7031
7799
6509
7686
8566
7096
8321
9308
7659
REFRIGERANT TYPE
Refrigerant Charge (kg)
Std Coil, Ckt A/Ckt B/Ckt C
MCHX Coil, Ckt A/Ckt B/Ckt C
COMPRESSORS
Quantity
Speed (r/s)
(Qty) Compressor Model Number Ckt A
(Qty) Compressor Model Number Ckt B
(Qty) Compressor Model Number Ckt C
Oil Charge (L, Ckt A/Ckt B/Ckt C)
No. Capacity Steps
Standard
Optional (Maximum)
Minimum Capacity Step (%)
Standard
Optional
Capacity (%)
Ckt A
Ckt B
Ckt C
COOLER
Weight (empty, kg)
Net Fluid Volume (L)
Maximum Refrigerant Pressure (kPa)
Maximum Water-Side Pressure
without Pumps (kPa)
Maximum Water-Side Pressure
with Pumps (kPa)
WATER CONNECTIONS (in.)
Inlet and Outlet, Victaulic
Drain (NPT)
7
8
7
8
8
9
9
10
9
10
10
11
11
12
12
13
13
8
14
10
13
9
10
6
11
8
10
7
9
7
8
6
62
38
N/A
57
43
N/A
50
50
N/A
38
28
36
33
33
33
30
30
40
36
36
28
33
33
33
689
278
3068
689
278
3068
689
278
3068
1080
327
3068
1080
327
3068
2068
2068
2068
2068
2068
2068
2068
2068
1034
1034
1034
1034
1034
1034
1034
1034
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
CONDENSER FANS
Standard Low Noise Type
Fan Speed (r/s) Standard
No. Blades...Diameter (mm)
No. Fans (Ckt A/Ckt B/Ckt C)
Total Airflow (L/s)
19
9762
6/4/
58 521
19
9762
6/4/
58 521
19
9762
6/6/
70 226
19
9762
4/4/4
70 226
19
9762
4/4/4
70 226
19
9762
4/4/6
81 930
19
9762
6/6/4
93 634
19
9762
6/6/6
105 339
CONDENSER COILS
No. Coils (Ckt A/Ckt B/Ckt C)
Total Face Area (sq m)
Max Working Refrigeration Pressure (kPa)
6/4/
21.83
4522
6/4/
21.83
4522
6/6/
26.2
4522
4/4/4
26.2
4522
4/4/4
26.2
4522
4/4/6
30.47
4522
6/6/4
34.84
4522
6/6/6
39.21
4522
589
65.9
4523
2068
589
65.9
4523
2068
589
65.9
4523
2068
9576
10 770
3/
8
3/
8
3/
5994
7188
Not available
7188
7188
8382
2255
2296.9
LEGEND
Aluminum Fin/Copper Tube Condenser Coil
Copper Fin/Copper Tube Condenser Coil
Electronic Expansion Valve
Microchannel Condenser Coil
Not Applicable
LEGEND
Aluminum Fin/Copper Tube Condenser Coil
Copper Fin/Copper Tube Condenser Coil
Electronic Expansion Valve
Microchannel Condenser Coil
10
315
10,266/10,266
11,472/11,472
9,475/9,475
4
162/106
162/106
83/55
83/55
330
345
360
10,601/10,266
10,601/10,601
12,013/10,601
11,807/11,472
11,807/11,807
13,460/11,807
9,799/9,475
9,799/9,799
11,064/9,799
R-410A, EXV Controlled System
4
4
4
14
14
(4) SH300
(3) SH240
(4) SH300
(3) SH240
52.5/39.4
52.5/39.4
(4) SH300
(3) SH300
(4) SH300
(3) SH240
52.5/39.4
52.5/39.4
14
16
14
16
14
16
15
17
16
18
6
5
6
4
7
6
7
5
6
5
1518
1518
73.5/73.5
445
300
162/162
162/130
83/87
83/64
12,013/12,013
13,460/13,460
11,064/11,064
162/130
162/130
83/64
83/64
Scroll, Hermetic
14
3500
(4) SH300
(3) SH300
(4) SH300
(3) SH300
52.5/39.4
52.5/39.4
31
19
31
19
162/130
162/106
83/64
83/55
390
162/162
162/162
83/87
83/87
15
16
(4) SH300
(4) SH300
(4) SH300
(3) SH300
52.5/52.5
52.5/39.4
(4) SH300
(4) SH300
(4) SH300
(4) SH300
52.5/52.5
52.5/52.5
30
29
27
22
21
27
30
29
27
18
21
20
Direct Expansion, Shell and Tube Type
1518
1518
1518
1518
1518
1518
73.5/73.5
73.5/73.5
73.5/73.5
445
445
445
300
300
300
25
25
25
25
1518
1518
73.5/73.5
445
300
3/
4
3/
3/
3/
3/
1140
9...30/9...30
9...30/9...30
20
6/4
6/4
248,000
1140
9...30/9...30
9...30/9...30
20
6/4
6/4
248,000
1140
9...30/9...30
9...30/9...30
22
6/6
6/4
272,800
1140
9...30/9...30
9...30/9...30
24
6/6
6/6
297,600
6/4
6/4
470
656
6/4
6/4
470
656
6/4
6/4
470
656
6/6
6/4
517
656
6/6
6/6
564
656
30RB315-390 SI
UNIT 30RB
OPERATING WEIGHT (Module A/Module B, kg)*
Al-Cu Condenser Coil
Cu-Cu Condenser Coil
MCHX Condenser Coil
REFRIGERANT TYPE
Circuits Qty
Refrigerant Charge
Std Coil, Module A Ckt A/Ckt B (kg)
Std Coil, Module B Ckt A/Ckt B (kg)
MCHX Coil, Module A Ckt A/Ckt B (kg)
MCHX Coil, Module B Ckt A/Ckt B (kg)
COMPRESSORS
Total Quantity
Speed (r/s)
Module A, (Qty) Compressor Model Number Ckt A
Module A, (Qty) Compressor Model Number Ckt B
Module B, (Qty) Compressor Model Number Ckt A
Module B, (Qty) Compressor Model Number Ckt B
Module A Oil Charge (L, Ckt A/Ckt B)
Module B Oil Charge (L, Ckt A/Ckt B)
No. Capacity Steps
Standard
Optional (Maximum)
Minimum Capacity Step (%)
Standard
Optional
Capacity (%)
Module A, Ckt A
Module A, Ckt B
Module B, Ckt A
Module B, Ckt B
COOLER
Module A Weight (empty, kg)
Module B Weight (empty, kg)
Net Fluid Volume (L) Module A/Module B
Maximum Refrigerant Pressure (kPa)
Maximum Water-Side Pressure (kPa)
WATER CONNECTIONS (in.)
Inlet and Outlet, Victaulic
Drain (NPT)
CONDENSER FANS
Standard Low Noise Type
Fan Speed (r/s) Standard
Module A No. Blades...Diameter (mm) Ckt A/Ckt B
Module B No. Blades...Diameter (mm) Ckt A/Ckt B
Total No. Fans
Module A No. Fans (Ckt A/Ckt B)
Module B No. Fans (Ckt A/Ckt B)
Total Airflow (L/s)
CONDENSER COILS
Module A No. Coils (Ckt A/Ckt B)
Module B No. Coils (Ckt A/Ckt B)
Total Face Area (sq m)
Max Working Refrigerant Pressure (kPa)
Al-Cu
Cu-Cu
EXV
MCHX
315
4656/4656
5203/5203
4297/4297
4
73.5/48.1
73.5/48.1
37.6/24.9
37.6/24.9
330
345
360
390
4808/4656
4808/4808
5448/4808
5354/5203
5354/5354
6104/5354
4444/4297
4444/4444
5018/4444
R-410A, EXV Controlled System
4
4
4
5448/5448
6104/6104
5018/5018
73.5/59.0
73.5/48.1
37.6/29.0
37.6/24.9
73.5/73.5
73.5/73.5
37.6/39.5
376/39.5
14
14
(4) SH300
(3) SH240
(4) SH300
(3) SH240
24.8/18.6
24.8/18.6
(4) SH300
(3) SH300
(4) SH300
(3) SH240
24.8/18.6
24.8/18.6
73.5/59.0
73.5/59.0
37.6/29.0
37.6/29.0
Scroll, Hermetic
14
58.3
(4) SH300
(3) SH300
(4) SH300
(3) SH300
24.8/18.6
24.8/18.6
14
16
14
16
14
16
15
17
16
18
6
5
6
4
7
6
7
5
6
5
31
19
31
19
689
689
278/278
3068
2068
73.5/73.5
73.5/59.0
37.6/39.5
37.6/29.0
15
16
(4) SH300
(4) SH300
(4) SH300
(3) SH300
24.8/24.8
24.8/18.6
(4) SH300
(4) SH300
(4) SH300
(4) SH300
24.8/24.8
24.8/24.8
30
29
27
22
21
27
30
29
27
18
21
20
Direct Expansion, Shell and Tube Type
689
689
689
689
689
689
278/278
278/278
278/278
3068
3068
3068
2068
2068
2068
25
25
25
25
689
689
278/278
3068
2068
3/
3/
4
3/
3/
3/
19
9...762/9...762
9...762/9...762
20
6/4
6/4
117 042
19
9...762/9...762
9...762/9...762
20
6/4
6/4
117 042
19
9...762/9...762
9...762/9...762
22
6/6
6/4
128 747
19
9...762/9...762
9...762/9...762
24
6/6
6/6
140 452
6/4
6/4
43.66
4522
6/4
6/4
43.66
4522
6/4
6/4
43.66
4522
6/6
6/4
48.03
4522
6/6
6/6
52.4
4522
LEGEND
Aluminum Fin/Copper Tube Condenser Coil
Copper Fin/Copper Tube Condenser Coil
Electronic Expansion Valve
Microchannel Condenser Coil
11
A
869
891
982
1159
1173
1319
A
731
728
893
1106
1142
A
1094
916
947
1122
627
899
H
1526
1228
1354
1584
1080
1435
Total
12,013
13,734
14,067
15,468
16,915
18,306
UNIT
30RB
190
210
225
250
275
300
A
992
1014
1106
1342
1355
1503
A
837
850
1015
1252
1289
A
1257
1018
1049
1283
732
1064
060
070
080
090
100
110
UNIT
30RB
120
130
150
160
170
Total
13,460
15,181
15,514
17,157
18,845
20,477
UNIT
30RB
190
210
225
250
275
300
A
800
821
911
1065
1079
1219
A
660
648
810
1020
1055
A
1007
852
881
1041
580
830
12
A
497
416
431
510
285
409
H
694
558
615
720
491
652
Total
5461
6243
6394
7031
7689
8321
A
451
461
503
610
616
683
A
380
386
461
569
586
A
571
463
477
583
333
484
H
765
603
660
793
534
723
Total
6118
6901
7052
7799
8566
9308
H
1405
1142
1260
1469
999
1324
A
332
330
405
503
519
H
1684
1326
1452
1744
1175
1591
A
395
405
447
527
533
600
Total
11,064
12,772
13,093
14,349
15,647
16,893
UNIT
30RB
190
210
225
250
275
300
A
363
372
413
483
489
553
A
299
294
367
463
478
A
457
386
400
472
263
376
H
637
518
571
666
453
600
Total
5019
5793
5937
6509
7096
7659
30RB060-110
B
30RB120-150
A
cooler
cooler
Compressors
Compressors
a30-3963
Compressors
cooler
cooler
a30-3964
Compressors
a30-3965
NOTE: Mounting weights are calculated at mounting locations. Refer to certified drawings starting on page 19 for mounting locations.
A
1085
1107
1193
1353
1366
1565
A
731
728
893
1238
1279
A
1094
Total
12,666
UNIT
30RB
190
A
1208
1230
1317
1537
1549
1749
A
837
850
1015
1382
1424
A
1257
A
332
330
405
563
582
A
497
H
694
Total
5757
Total
14,113
A
493
503
542
615
621
711
UNIT
30RB
190
A
549
559
599
699
704
795
A
380
386
461
628
647
A
571
Total
6415
13
A
1008
1030
1115
1251
1265
1456
A
660
648
810
1148
1188
A
1012
Total
11,717
UNIT
30RB
190
A
457
467
506
567
574
660
A
299
294
367
521
539
A
459
Total
5313
A
1218
1240
1372
1518
1530
1741
A
731
728
893
1336
1383
A
1094
H
1526
Total
13,258
UNIT
30RB
190
A
1341
1363
1495
1702
1714
1926
A
837
850
1015
1481
1527
A
1257
060
070
080
090
100
110
UNIT
30RB
120
130
150
160
170
UNIT
30RB
190
14
A
1137
1158
1289
1411
1424
1626
A
660
648
810
1244
1289
A
1016
A
497
H
1526
Total
6014
A
610
620
680
774
779
875
A
380
386
461
673
694
A
571
Total
6669
Total
4,616
4,811
5,190
6,372
6,586
6,950
A
332
330
405
607
629
Total
14,705
A
554
564
624
690
695
791
060
070
080
090
100
110
UNIT
30RB
120
130
150
160
170
Total
12,309
UNIT
30RB
190
A
516
525
585
640
646
737
A
299
294
367
564
585
A
461
Total
2094
2182
2355
2890
2987
3152
H
643
Total
5582
A
1185
1204
1302
1507
1516
1671
A
842
846
1017
1229
1268
A
962
Total
12580
UNIT
30RB
190
A
538
546
590
683
688
758
A
382
384
462
557
575
A
436
Total
5706
15
ITEM
Condenser Coil Options
MCHX E-Coat
Aluminum Fin/Copper Tube
Aluminum Fin/Copper Tube, Pre-Coated
Aluminum Fin/Copper Tube, E-Coat
Copper Fin/Copper Tube, E-Coat
Copper Fin/Copper Tube Condenser Coils
Heat Reclaim Condenser
Controls/Communication Options
BACnet Communication
BACnet Translator Control
Chillervisor System Manager III Multi-Unit Control
Energy Management Module
LON (Local Operating Network) Translator Control
Navigator Display
Remote Service Port
Remote Enhanced Display
Service Option
Touch Pilot Display
Dual Chiller Accessory Kit
Cooler Options
Freeze Protection Cooler Heaters
Remote Cooler
CRN Cooler (Canada Only)
Electrical/Low Sound Options
Unit-Mounted Main Disconnect, Non-Fused
Convenience Outlet
High SCCR (includes non-fused disconnect)
Low Sound - Compressor Sound Reduction Blankets
Ultra Low Sound - Compressor Sound Reduction Enclosures
Hydronics Option
Hydronic Pump Package (with or without VFD)
Refrigeration Circuit Options
Compressor Suction Service Valve
Low Ambient Temperature Head Pressure Control
Minimum Load Control (not available with Leaving Fluid Temperature < 38 F)
Suction Line Insulation
Security/Packaging Options
Condenser Coil Trim Panels
Security Grilles
Full Hail Guard
Upper Hail Guard
Full End Screen
Factory-installed options
Condenser coil options are available to match coil construction to the site conditions for the best durability. Refer
to the Condenser Coil Corrosion Protection Options table
on page 18 or the appropriate selection guide for more
information.
Heat reclaim option adds a water-cooled condenser in
parallel with the standard air-cooled condenser for the purpose of simultaneously producing tempered hot water
while satisfying the chilled water requirement. This full heat
reclaim option can lower overall building energy consumption significantly, producing total COP (coefficient of performance) values of 6.0 or greater. This option is not
available on unit sizes 210-390 or with the hydronic pump
package option. Heat reclaim option only available with
MCHX.
Compressor suction service valve provides additional
isolation of the compressor from the cooler vessel for
16
FIELD-INSTALLED
ACCESSORY
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
the entire unit end (both ends), and, with its hinged design,
is not identical to this option.
High SCCR (short circuit current rating) devices allow the
chiller to tolerate a 65 kA (208/230 and 460-v units) or
25 kA (575-v units) short circuit current for a brief period
of time while protecting downstream components. The
high SCCR provides a higher level of protection than the
standard chiller components. This option is not available
on 30RB060-120 with dual point power. This option is
also not available for 30RB170 and 30RB190 208/230-v
single point models and 30RB275 and 30RB300 208/
230-v dual point models. This option includes the unitmounted non-fused disconnect option.
Low sound - compressor sound blankets reduce unit
sound levels by providing an acoustic blanket on each compressor.
Ultra low sound - compressor sound enclosures
provide enclosures which encase compressors that are covered with acoustic blankets.
BACnet communication option provides factoryinstalled communication capability with a BACnet MS/TP
network. Allows integration with i-Vu Open control system or a BACnet building automation system.
BACnet translator control provides an interface
between the chiller and a BACnet Local Area Network
(LAN, i.e.,MS/TP EIA-485). BACnet translator control is
also available as a field-installed accessory. Field programming is required.
LON translator control interface between the chiller
and a Local Operating Network (LON, i.e., LonWorks*
FT-10A ANSI/EIA-709.1). LON translator control is also
available as a field-installed accessory. Field programming
is required.
Field-installed accessories
Minimum load control accessory allows additional
capacity reduction for unit operation below the minimum
step of unloading (down to 6% of the minimum unit capacity, depending on unit size) via hot gas bypass. This accessory is not available on applications with leaving fluid
temperature less than 38 F (3.3 C).
Full hail guard consists of hinged, louvered panels,
which cover both ends of the unit. This accessory provides
complete protection from hail and flying debris. For hail
protection, two factory options are also available. These
options directly fasten to the end of the chillers (are not
hinged), and therefore are not identical to this accessory.
Navigator display accessory provides a portable handheld display for convenient access to unit status, operation,
configuration and troubleshooting diagnostics capability.
The four-line, 80-character LCD display provides clear
language information in English, French, Spanish, or
Portuguese. The weatherproof enclosure and industrial
grade extension cord enables the Navigator display to be
ideally suited for outdoor applications. Magnets located on
the back of the module allow attachment to any sheet
metal component for hands-free operation.
17
Standard
Mild
Coastal
ENVIRONMENT
Severe
Industrial
Coastal
See NACO Packaged Chiller Builder
Combined
Industrial/Coastal
X
X
X
X
LEGEND
AL
Aluminum
CU
Copper
NACO North American Commercial Operations
* See NACO Packaged Chiller Builder for details. Additional corrosion protection is available. For Novation or round tube/plate fin (RTPF) heat
exchangers, see selection guide Environmental Corrosion Protection (Publication 04-581061-01).
18
5150
2641
4317
1932
30RB-070
4799
2181
4593
2088
5632
2560
5426
2466
3978
1804
3783
1716
4811
2182
4616
2094
4944
2247
4111
1869
a30-5176
30RB-060
1165
[45.86]
1164
[45.82]
1013
[39.88]
1038
[40.86]
WEIGHT MAX WEIGHT WEIGHT MAX WEIGHT WEIGHT MAX WEIGHT CENTER OF GRAVITY
CU/AL CU/AL PUMP CU/CU CU/CU PUMP MCHX
MCHX PUMP
CGx
CGy
lb/kg
lb/kg
lb/kg
lb/kg
lb/kg
lb/kg
MM [INCH] MM [INCH]
281.03
[11.06 ]
PS
y
PD
675.6
[26.6]
309.9
[12.2]
353.1
[13.9]
353.1
[13.9]
Z
.25
381.0
[15.0]
381.0
[15.0]
482.6
[19.0]
482.6
[19.0]
Y
.25
188.0
[7.4]
188.0
[7.4]
Z
.25
X
.25
309.9
[12.2]
Y
.25
408.89
[16.10 ]
PS
PD
COOLER DRAIN
3/4" NPT
PUMP PACKAGE
LEAVING WATER
4" VICTAULIC
2281.37
[89.82 ]
PD
X
.25
675.6
[26.6]
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface for airflow.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute
for draining.
3. Temperature relief devices located on suction line, liquid line and filter drier of each circuit and have 1/4
flare connection.
4. Units without a pump package have the same leaving
water connection, Y and Z dimensions (entering
water), and Pump Discharge X dimensions as units
with a pump package.
5. Dimensions are in mm [inches].
COOLER TUBE
SERVICE AREA
1447.8[57.0]
PS
x
CIRCUIT
B
COMPRESSORS
CG
518.30
[20.41 ]
2393.08
[94.22 ]
1714.90
[67.52 ]
298.45
[11.75 ]
CIRCUIT
A
COMPRESSOR
408.89
[16.10 ]
SEE DETAIL
376.01
[14.80 ]
215.73
[8.49 ]
860.93
[33.89 ]
2438.40
[96.00]
414.47
[16.32 ]
2236.08
[88.03 ]
NO PUMP PACKAGE
ENTERING WATER
4" VICTAULIC
(SEE NOTE 4)
804.35
[31.67 ]
CG
246.36
[9.70 ]
DETAIL A
SCALE 1:2
200.00
[7.87 ]
2159.89
[85.04 ]
BACnet COMMUNICATION
OPTION KNOCKOUT
FOR 1/2" CONDUIT
AIR FLOW
100.00
[3.94 ]
949.14
[37.37 ]
38.09
[1.50 ]
336.50
[13.25 ]
190.00
[7.48 ]
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
CONTROL/POWER BOX
ALL VOLTAGES
22.2[.87]
MOUNTING HOLE
40.00
[1.57 ]
RIGGING HOLE
38.00
[1.50 ]
Dimensions
19
20
4600
2091
5523
2511
5082
2310
6005
2730
30RB-080
a30-5177
y
408.89
[16.10 ]
PS
4267
1934
5190
2355
1206
[47.48]
1012
[39.84]
353.1
[13.9]
381.0
[15.0]
497.8
[19.6]
Y
.25
170.2
[6.7]
Z
.25
X
.25
309.9
[12.2]
Z
.25
Y
.25
2393.08
[94.22 ]
PUMP PACKAGE
ENTERING WATER
4" VICTAULIC
1692.75
[66.64 ]
PIPING ENTRANCE AREA
X
.25
675.6
[26.6]
PD
PS
COOLER DRAIN
3/4" NPT
PUMP PACKAGE
LEAVING WATER
4" VICTAULIC
CENTER OF GRAVITY
WEIGHT MAX WEIGHT WEIGHT MAX WEIGHT WEIGHT MAX WEIGHT
CU/AL CU/AL PUMP CU/CU CU/CU PUMP MCHX
MCHX PUMP
CGx
CGy
lb/kg
lb/kg
lb/kg
lb/kg
lb/kg
lb/kg
MM [INCH] MM [INCH]
PD
2281.37
[89.82 ]
296.47
[11.67 ]
PS
PD
COOLER TUBE
SERVICE AREA
COOLER VENT
1/4" NTP
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface for airflow.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute
for draining.
3. Temperature relief devices located on suction line, liquid line and filter drier of each circuit and have 1/4
flare connection.
4. Units without a pump package have the same leaving
water connection, Y and Z dimensions (entering
water), and Pump Discharge X dimensions as units
with a pump package.
5. Dimensions are in mm [inches].
1447.8 [57.00]
CG
x
CIRCUIT
CIRCUIT
A
B
COMPRESSORS COMPRESSORS
2236.08
[88.03 ]
408.90
[16.10 ]
521.16
[20.52 ]
386.88
[15.23 ]
SEE DETAIL
NO PUMP PACKAGE
ENTERING WATER
4" VICTAULIC
(SEE NOTE 4)
403.76
[15.90 ]
788.34
[31.04 ]
CG
215.73
[8.49 ]
864.00
[34.02 ]
2159.89
[85.035 ]
UNIT MOUNTING
200.00
[7.87 ]
949.14
[37.37 ]
100.00
[3.94 ]
246.36
[9.70 ]
AIR FLOW
BACnet COMMUNICATION
OPTION KNOCKOUT
FOR 1/2" CONDUIT
SCROLLING MARQUEE
DISPLAY
2438.40
[96.00]
DETAIL A
SCALE 11:32
38.09
[1.50 ]
336.50
[13.25 ]
190.00
[7.48 ]
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
22.2[.87]
MOUNTING HOLE
45.00
[1.77 ]
RIGGING HOLE
19.00
[0.75 ]
Dimensions (cont)
a30-5178
21
7078
3217
6155
2798
30RB-090
30RB-100
6879
3127
6656
3026
7802
3547
7579
3445
5663
2569
5449
2472
6586
2987
6372
2890
6855
3116
5932
2697
1614
[63.5]
1625
[64.0]
999
[39.3]
1017
[40.0]
CENTER OF GRAVITY
WEIGHT MAX WEIGHT WEIGHT MAX WEIGHT WEIGHT MAX WEIGHT
CU/AL CU/AL PUMP CU/CU CU/CU PUMP MCHX
MCHX PUMP
CGx
CGy
lb/kg
lb/kg
lb/kg
lb/kg
lb/kg
lb/kg
MM [INCH] MM [INCH]
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface for airflow.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute
for draining.
3. Temperature relief devices located on suction line, liquid line and filter drier of each circuit and have 1/4
flare connection.
4. Units without a pump package have the same leaving
water connection, Y and Z dimensions (entering
water), and Pump Discharge X dimensions as units
with a pump package.
5. Dimensions are in mm [inches].
PD
y
1389.4
[54.7]
1389.4
[54.7]
X
.25
309.9
[12.2]
309.9
[12.2]
Y
.25
408.89
[16.10 ]
PS
353.1
[13.9]
353.1
[13.9]
Z
.25
PD
PS
1017.46
[40.06 ]
PD
X
.25
1097.3
[43.2]
497.8
[19.6]
497.8
[19.6]
Y
.25
170.2
[6.7]
170.2
[6.7]
Z
.25
1097.3
[43.2]
COOLER DRAIN
3/4" NPT
2281.37
[89.82 ]
PUMP PACKAGE
LEAVING WATER
4" VICTAULIC
COOLER TUBE
SERVICE AREA
1447.8[57.0]
CIRCUIT A
COMPRESSORS
PUMP PACKAGE
ENTERING WATER
4" VICTAULIC
3587.08
[141.22 ]
292.20
[11.50 ]
CG
2195.16
[86.42 ]
2769.30
[109.03 ]
UNIT MOUNTING
COOLER VENT
1/4" NTP
1632.07
[64.25 ]
PIPING ENTRANCE AREA
CIRCUIT B
COMPRESSORS
992.44
[39.07 ]
937.55
[36.91 ]
PS
SEE DETAIL
391.88
[15.43 ]
NO PUMP PACKAGE
ENTERING WATER
4" VICTAULIC
(SEE NOTE 4)
215.73
[8.49 ]
864.00
[34.02 ]
100.00
[3.94 ]
2156.30
[84.89 ]
UNIT MOUNTING
246.36
[9.70 ]
AIR FLOW
938.35
[36.94 ]
DETAIL B
SCALE 3:16
200.00
[7.87 ]
BACnet COMMUNICATION
OPTION KNOCKOUT
FOR 1/2" CONDUIT
SCROLLING MARQUEE
DISPLAY
2438.40
[96.00]
2236.08
[88.03 ]
788.35
[31.04 ]
CG
39.89
[1.57 ]
336.50
[13.25 ]
190.00
[7.48 ]
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
22.2[.87]
MOUNTING HOLE
45.00
[1.77 ]
RIGGING HOLE
38.00
[1.50 ]
22
a30-5179
30RB-110
COOLER VENT
1/4" NTP
COOLER DRAIN
3/4" NPT
PD
y
408.89
[16.10 ]
PD
PS
PUMP PACKAGE
LEAVING WATER
6" VICTAULIC
2281.37
[89.82 ]
PS
224.84
[8.85 ]
PD
z
PS
x
6519
2963
7442
3383
7243
3292
8166
3712
6027
2734
6950
3152
3587.08
[141.22 ]
997
[39.25]
856.0
[33.7]
X
.25
281.9
[11.1]
Y
.25
60.9
[2.4]
Z
.25
2728.56
[107.42 ]
SEE DETAIL
1713
[67.44]
CG
CIRCUIT A
COMPRESSORS
2446.09
[96.30 ]
PIPING ENTRANCE AREA
CIRCUIT B
COMPRESSORS
CENTER OF GRAVITY
WEIGHT MAX WEIGHT WEIGHT MAX WEIGHT WEIGHT MAX WEIGHT
CU/AL CU/AL PUMP CU/CU CU/CU PUMP MCHX
MCHX PUMP
CGx
CGy
lb/kg
lb/kg
lb/kg
lb/kg
lb/kg
lb/kg
MM [INCH] MM [INCH]
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface for airflow.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of
volute for draining.
3. Temperature relief devices located on suction line,
liquid line and filter drier of each circuit and have 1/4
flare connection.
4. Units without a pump package have the same leaving water connection, Y and Z dimensions (entering
water), and Pump Discharge X dimensions as units
with a pump package.
5. Dimensions are in mm [inches].
COOLER TUBE
SERVICE AREA
1447.8[57.0]
408.89
[16.10 ]
X
.25
340.4
[13.4]
Y
.25
391.2
[15.4]
391.88
[15.43 ]
Z
.25
233.7
[9.2]
2156.30
[84.89 ]
UNIT MOUNTING
246.36
[9.70 ]
938.35
[36.94 ]
39.89
[1.57 ]
336.50
[13.25 ]
190.00
[7.48 ]
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
22.2[.87]
MOUNTING HOLE
45.00
[1.77 ]
RIGGING HOLE
38.00
[1.50 ]
DETAIL B
SCALE 3:16
200.00
[7.87 ]
AIR FLOW
100.00
[3.94 ]
BACnet COMMUNICATION
OPTION KNOCKOUT
FOR 1/2" CONDUIT
215.73
[8.49 ]
860.81
[33.89 ]
SCROLLING MARQUEE
DISPLAY
NO PUMP PACKAGE
ENTERING WATER
6" VICTAULIC
(SEE NOTE 4)
992.44
[39.07 ]
2438.40
[96.00]
COIL SERVICE AREA
2236.08
[88.03 ]
761.94
[30.00 ]
CG
916.15
[36.07 ]
Dimensions (cont)
a30-5180
23
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface for airflow.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute for draining.
3. Temperature relief devices located on suction line, liquid line and filter
drier of each circuit and have 1/4flare connection.
4. Units without a pump package have the same leaving water connection, Y and Z dimensions (entering water), and Pump Discharge X
dimensions as units with a pump package.
5. Dimensions are in mm [inches].
a30-5181
24
MCHX Microchannel Condenser Coil
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface for airflow.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute for draining.
3. Temperature relief devices located on suction line, liquid line and filter drier
of each circuit and have 1/4flare connection.
4. Units without a pump package have the same leaving water connection, Y
and Z dimensions (entering water), and Pump Discharge X dimensions as
units with a pump package.
5. Dimensions are in mm [inches].
Dimensions (cont)
769.51
[30.30 ]
PD
PD
408.89
[16.10 ]
PD
PS
COOLER DRAIN
3/4" NPT}
11511
5232
11846
5385
10266
4666
11807
5367
11472
5215
13052
5933
12717
5781
9799
4443
9475
4297
11044
5009
10720
4860
3114
[122.59]
3065
[120.66]
101.20
[3.98 ]
PS
x
978
[30.5]
994
[39.13]
Y
.25
Z
.25
X
.25
Y
.25
Z
.25
5975.08
[235.24 ]
1808.48 381
297.2 883.92 421.64 231.14
[71.2] [15.0] [11.7] [34.8] [16.6] [9.1]
1808.48 381
297.2 883.92 421.64 231.14
[71.2] [15.0] [11.7] [34.8] [16.6] [9.1]
X
.25
1456.33
[57.34 ]
4164.06
[163.94 ]
CIRCUIT A
COMPRESSORS
PUMP PACKAGE
ENTERING WATER
6" VICTAULIC
2388.00
[94.016 ]
UNIT MOUNTING
923.39
[36.35 ]
800.00
[31.50 ]
1483.83
[58.42 ]
CIRCUIT B
COMPRESSORS
WEIGHT MAX WEIGHT WEIGHT MAX WEIGHT WEIGHT MAX WEIGHT CENTER OF GRAVITY
CU/AL CU/AL PUMP CU/CU CU/CU PUMP MCHX
MCHX PUMP
CGx
CGy
lb/kg
lb/kg
lb/kg
lb/kg
lb/kg
lb/kg
MM [INCH] MM [INCH]
30RB-170
10601
330A,345A/B,360B 4819
30RB-160
315A/B,330B
PUMP PACKAGE
2281.37 LEAVING WATER
6" VICTAULIC
[89.82 ]
PS
COOLER TUBE
SERVICE AREA
1447.8
[57.00]
2016.54
[79.39 ]
A
x
1993.25
[78.47 ]
2073.54
[81.64 ]
2769.30
[109.03 ]
UNIT MOUNTING
CG
2438.40
[96.00]
408.89
[16.10 ]
422.24
[16.62 ]
BACnet COMMUNICATION
OPTION KNOCKOUT
FOR 1/2" CONDUIT
938.35
[36.94 ]
200.00
[7.87 ]
100.00
[3.94 ]
DETAIL B
SCALE 3:16
400.00
[15.75 ]
VIEW-A-A
2156.30
[84.89 ]
UNIT MOUNTING
AIR FLOW
200.00
[7.87 ]
39.89
[1.57 ]
215.73
864.00 [8.49 ]
[34.02 ]
SCROLLING MARQUEE
DISPLAY
NO PUMP PACKAGE
ENTERING WATER
6" VICTAULIC
(SEE NOTE 4)
755.58
[29.75 ]
2236.08
[88.03 ]
CG
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
(DUAL AND SINGLE POINT)
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface for airflow.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute for draining.
3. Temperature relief devices located on suction line, liquid line and filter drier of each circuit and have 1/4
flare connection.
4. Units without a pump package have the same leaving water connection, Y and Z dimensions (entering
water), and Pump Discharge X dimensions as units with a pump package.
MCHX Microchannel Condenser Coil
5. Dimensions are in mm [inches].
a30-5182
25
246.36
[9.70 ]
336.50
[13.25 ]
190.00
[7.48 ]
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
(DUAL POINT 230V ONLY)
(DUAL POWER NFD
CIRCUIT B 380,460,575V
ONLY)
22.2 [.87]
MOUNTING HOLE
RIGGING HOLE
38.00
[1.50 ]
SEE DETAIL
240.00
[9.45 ]
26
PS
PS
PD
PS
x
13460
6118
14705
14705
11064
5019
12309
5582
13258
6014
3578
[140.87]
974
[38.35]
Y
.25
297.2
[11.7]
Z
.25
X
.25
2080.3
[81.9]
Y
.25
421.6
[16.6]
Z
.25
231.1
[9.1]
CG
x
4164.26
[163.95 ]
CIRCUIT A
COMPRESSORS
1297.44
[51.08 ]
7169.08
[282.25 ]
812.70
[32.00 ]
PUMP PACKAGE
ENTERING WATER
6" VICTAULIC
3002
381
[118.2] [15.0]
X
.25
800.00
[31.50 ]
3208.06
[126.30 ]
PIPING ENTRANCE AREA
923.19
[36.35 ]
1345.70
[52.98 ]
CIRCUIT B
COMPRESSORS
CGy
MM [INCH]
CENTER OF GRAVITY
COOLER DRAIN
3/4" NPT
1963.74
[77.31 ]
30RB-190,
12013
360A,390A/B 5461
a30-5183
408.89
[16.10 ]
PD
PUMP PACKAGE
LEAVING WATER
6" VICTAULIC
2281.37
[89.82 ]
COOLER VENT
1/4" NTP
PD
COOLER TUBE
SERVICE AREA
960.40
[37.81 ]
3208.00
[126.30 ]
2073.54
[81.64 ]
1997.28
[78.63 ]
SCROLLING MARQUEE
DISPLAY
422.24
[16.62 ]
BACnet COMMUNICATION
OPTION KNOCKOUT
FOR 1/2" CONDUIT
2156.30
[84.89 ]
UNIT MOUNTING
200.00
[7.87 ]
938.35
[36.94 ]
100.00
[3.94 ]
DETAIL B
SCALE 1:4
VIEW A-A
SCALE 1:16
39.89
[1.57 ]
215.71
[8.49 ]
931.93
[36.69 ]
NO PUMP PACKAGE
ENTERING WATER
6" VICTAULIC
(SEE NOTE 4)
408.89
[16.10 ]
2438.40
[96.00]
AIR FLOW
200.00
[7.87 ]
400.00
[15.75 ]
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
(DUAL AND SINGLE POINT)
22.2 [.87]
MOUNTING HOLE
RIGGING HOLE
38.00
[1.50 ]
246.36
[9.70 ]
336.50
[13.25 ]
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
(DUAL POINT 230V ONLY)
(DUAL POWER NFD
CIRCUIT B 380,460,575V
ONLY)
200.00
[7.87 ]
B
240.00
[9.45 ]
SEE DETAIL
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute for draining.
3. Temperature relief devices located on suction line, liquid line and
filter drier of each circuit and have 1/4flare connection.
4. Dimensions are in mm [inches].
2236.08
[88.03 ]
755.58
[29.75 ]
CG
Dimensions (cont)
15181
6901
15514
7052
13734
6243
14067
6394
30RB-210
30RB-225
13093
5937
12772
5793
WEIGHT
MCHX
lb/kg
437.86
[17.24 ]
3588
[141.26]
3528
[138.90]
CGx
MM [INCH]
906
[35.67]
917
[36.10]
CGy
MM [INCH]
CENTER OF GRAVITY
1348.58
[53.09 ]
1575.30
[62.02 ]
UNIT MOUNTING
1256.59
[49.47 ]
WEIGHT
CU/CU
lb/kg
408.89
[16.10 ]
COOLER DRAIN
3/4" NPT
LEAVING WATER
6" VICTAULIC
COOLER VENT
1/4" NPT
759.89
[29.92 ]
COOLER TUBE
SERVICE AREA
1447.8
[57.0]
930.95
[36.652 ]
CIRCUIT C
COMPRESSORS
2016.54
[79.39 ]
WEIGHT
CU/AL
lb/kg
2281.37
[89.82 ]
a30-5184
27
1885.22
[74.221 ]
CIRCUIT B
COMPRESSORS
7169.08
[282.25 ]
2794.35
[110.01 ]
UNIT MOUNTING
437.86
[17.24 ]
POWER BOX 2
230V ONLY
CKT C
800.00
[31.50 ]
800.00
[31.50 ]
POWER BOX 1
230V CKT B
380V,460V,575V
CKT A,B,C
1990.54
[78.37 ]
2690.32
[105.92 ]
CIRCUIT A
COMPRESSORS
CG
2806.54
[110.49 ]
1981.65
[78.02 ]
UNIT MOUNTING
ENTERING WATER
6" VICTAULIC
408.89
[16.10 ]
760.39
[29.94 ]
2236.08
[88.03 ]
CG
y
39.89
[1.57 ]
864.00
[34.02 ]
SCROLLING MARQUEE
DISPLAY
2438.40
[96.00]
2156.30
[84.89 ]
UNIT MOUNTING
BACnet COMMUNICATION
OPTION KNOCKOUT
FOR 1/2" CONDUIT
AIR FLOW
938.35
[36.94 ]
240.00
[9.45 ]
22.2[.87]
MOUNTING HOLE
DETAIL B
SCALE 1:4
RIGGING HOLE
38.00
[1.50 ]
200.00
[7.87 ]
215.73
[8.49 ]
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
(DUAL POINT 230V ONLY)
(DUAL POWER NFD
CIRCUIT B 380,460,
575V ONLY)
POWER BOX
230V ONLY (CKT A)
200.00
[7.87 ]
100.00
[3.94 ]
SEE DETAIL
200.00
[7.87 ]
400.00
[15.75 ]
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
PEB1 230V DUAL POINT
380V,460V,575V DUAL & SINGLE POINT
PEB2 230V DUAL POINT
380V,460V,575V DUAL POINT
VIEW-A-A
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface.
Side 8 required for coil service area.
2. Temperature relief devices located on suction line, liquid line and
filter drier of each circuit and have 1/4flare connection.
3. Dimensions are in mm [inches].
a30-5185
28
17157
7799
15468
7031
14349
6509
WEIGHT
MCHX
lb/kg
4022
[158.35]
CGx
MM [INCH]
910
[35.86]
CGy
MM [INCH]
CENTER OF GRAVITY
2542.58
[100.10 ]
2769.30
[109.03 ]
UNIT MOUNTING
437.86
[17.24 ]
2416.18
[95.13 ]
30RB-250
WEIGHT
CU/CU
lb/kg
WEIGHT
CU/AL
lb/kg
408.89
[16.10 ]
LEAVING WATER
6" VICTAULIC
2281.37
[89.82 ]
COOLER VENT
1/4 NPT
761.93
[30.00 ]
COOLER TUBE
SERVICE AREA
1447.8
[57.00]
3154.63
[124.20 ]
CIRCUIT C
COMPRESSORS
1941.86
[76.45 ]
CIRCUIT B
COMPRESSORS
2794.35
[110.01 ]
UNIT MOUNTING
8363.08
[329.26 ]
437.86
[17.24 ]
POWER BOX 2
380V,460V,575V
CKT C
1020.13
[40.16 ]
101.20
[3.98 ]
800.00
[31.50 ]
POWER BOX 1
380V,460V,575V
CKT A,B
800.00
[31.50 ]
1990.54
[78.37 ]
2806.54
[110.49 ]
1981.65
[78.02 ]
UNIT MOUNTING
ENTERING WATER
6" VICTAULIC
2693.73
[106.05 ]
CIRCUIT A
COMPRESSORS
CGx
2438.40
[96.00]
408.89
[16.10 ]
39.89
[1.57 ]
964.00
[37.95 ]
SCROLLING MARQUEE
DISPLAY
FAN ELECTRICAL BOX
(FEB)
ALL VOLTAGES
2156.30
[84.89 ]
UNIT MOUNTING
BACnet COMMUNICATION
OPTION KNOCKOUT
FOR 1/2" CONDUIT
AIR FLOW
200.00
[7.87 ]
100.00
[3.94 ]
DETAIL B
SCALE 3:16
7/8" KNOCKOUT TO BE
USED FOR LOCATING
400.00
FIELD POWER WIRING
[15.75 ]
PEB1 230V DUAL POINT
380V,460V,575V DUAL & SINGLE POINT
PEB2 ALL VOLTAGES DUAL POINT
2236.08
[88.03 ]
761.93
[30.00 ]
CGy
VIEW A - A
SCALE 1:16
938.35
[36.94 ]
22.2 [.87]
MOUNTING HOLE
RIGGING HOLE
38.00
[1.50 ]
200.00
[7.874 ]
B
240.00
[9.45 ]
215.75
[8.49 ]
SEE DETAIL
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface.
Side 8 required for coil service area.
2. Temperature relief devices located on suction line, liquid line and
filter drier of each circuit and have 1/4flare connection.
3. Dimensions are in mm [inches].
Dimensions (cont)
18845
8566
16915
7689
15647
7096
WEIGHT
MCHX
lb/kg
4857
[191.22]
CGx
MM [INCH]
914
[35.98]
CGy
MM [INCH]
CENTER OF GRAVITY
2223.58
[87.54 ]
1575.30
[62.02 ]
UNIT MOUNTING
LEAVING WATER
6" VICTAULIC
COOLER VENT
1/4" NPT
2097.41
[82.58 ]
CIRCUIT C
COMPRESSORS
30RB-275
WEIGHT
CU/CU
lb/kg
WEIGHT
CU/AL
lb/kg
408.89
[16.10 ]
437.86
[17.24 ]
2281.37
[89.82 ]
759.39
[29.90 ]
COOLER TUBE
SERVICE AREA
1447.8
[57.0]
101.20
[3.98 ]
2016.54
[79.39 ]
a30-5186
29
CIRCUIT B
COMPRESSORS
2782.00
[109.53 ]
3582.00
[141.02 ]
UNIT MOUNTING
437.86
[17.24 ]
9557.08
[376.26 ]
POWER BOX 2
380V,460V,575V
CKT C
800.00
[31.50 ]
4319.54
[170.06 ]
ENTERING WATER
6" VICTAULIC
POWER BOX 1
380V,460V,575V
CKT A,B
4231.79
[166.61 ]
3582.00
[141.02 ]
UNIT MOUNTING
CIRCUIT A
COMPRESSORS
CGx
800.00
[31.50 ]
SCROLLING MARQUEE
DISPLAY
2438.40
[96.00]
2156.30
[84.89 ]
UNIT MOUNTING
AIR FLOW
200.00
[7.87 ]
BACnet COMMUNICATION
OPTION KNOCKOUT
FOR 1/2" CONDUIT
39.89
[1.57 ]
964.00
[37.95 ]
100.00
[3.94 ]
DETAIL B
SCALE 9:40
400.00
7/8" KNOCKOUT TO BE
[15.75 ]
USED FOR LOCATING
FIELD POWER WIRING
PEB1 230V DUAL POINT
380V,460V,575V DUAL & SINGLE POINT
PEB2 ALL VOLTAGES DUAL POINT
408.89
[16.10 ]
759.39
[29.90 ]
2236.08
[88.03 ]
CGy
VIEW A - A
SCALE 9:160
938.35
[36.94 ]
215.73
[8.49 ]
22.2[.87]
MOUNTING HOLE
45.00
[1.77 ]
RIGGING HOLE
38.00
[1.50]
200.00
[7.87 ]
SEE DETAIL
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface.
Side 8 required for coil service area.
2. Temperature relief devices located on suction line, liquid line and filter
drier of each circuit and have 1/4flare connection.
3. Dimensions are in mm [inches].
a30-5187
30
20477
9308
18306
8321
16893
7659
WEIGHT
MCHX
lb/kg
COOLER DRAIN
3/4" NPT
COOLER VENT
1/4" NPT
5317
[203.33]
CGx
MM [INCH]
916
[36.06]
CGy
MM [INCH]
CENTER OF GRAVITY
3417.58
[134.55 ]
2769.30
[109.03 ]
UNIT MOUNTING}
LEAVING WATER
6" VICTAULIC
CIRCUIT C
COMPRESSORS
3295.57
[129.75 ]
30RB-300
WEIGHT
CU/CU
lb/kg
WEIGHT
CU/AL
lb/kg
408.89
[16.10 ]
2281.37
[89.82 ]
761.93
[30.00 ]
COOLER TUBE
SERVICE AREA
1447.8
[57.00]
3210.54
[126.40 ]
800.00
[31.50 ]
437.86
[17.24 ]
10751.08
[423.27 ]
3582.00
[141.024 ]
UNIT MOUNTING
ENTERING WATER
6" VICTAULIC
3342.24
[131.58 ]
PIPING ENTRANCE AREA
CIRCUIT B
COMPRESSORS
POWER BOX 2
380V,460V,575V
CKT C
A
800.00
[31.50 ]
4113.26
[161.94 ]
CIRCUIT A
COMPRESSORS
CGx
4319.54
[170.06 ]
3582.00
[141.024 ]
UNIT MOUNTING
437.86
[17.24 ]
A
3158.54
[124.35 ]
POWER BOX 1
380V,460V,575V
CKT A,B
2236.08
[88.03 ]
408.89
[16.10 ]
761.93
[30.00 ]
CGy
BACnet COMMUNICATION
OPTION KNOCKOUT
FOR 1/2" CONDUIT
864.00
[34.02 ]
SCROLLING MARQUEE
DISPLAY
2438.40
[96.00]
7/8" KNOCKOUT TO BE
USED FOR LOCATING
400.00
FIELD POWER WIRING
[15.75 ]
PEB1 230V DUAL POINT
380V,460V,575V DUAL & SINGLE POINT
PEB2 ALL VOLTAGES DUAL POINT
VIEW A-A
SCALE 1:10
2156.30
[84.894 ]
UNIT MOUNTING
938.35
[36.94 ]
215.73
[8.49 ]
DETAIL B
SCALE 1:5
SEE DETAIL
39.89
[1.57 ]
AIR FLOW
200.00
[7.87 ]
100.00
[3.94 ]
200.00
[7.874 ]
240.00
[9.45 ]
22.2[.87]
45.00
[1.77 ]
RIGGING HOLE
38.00
[1.50 ]
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface.
Side 8 required for coil service area.
2. Temperature relief devices located on suction line, liquid line and filter drier of each circuit and have 1/4flare connection.
3. Dimensions are in mm [inches].
Dimensions (cont)
a30-4734
31
HR
Heat Reclaim
MCHX Microchannel Condenser Coil
LEGEND
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute
for draining.
3. Temperature relief devices located on suction line, liquid line and filter drier of each circuit and have 1/4
flare connection.
4. Chillers with heat reclaim option do not have a pump
package.
5. Dimensions are in mm [inches].
32
a30-4735
HR
Heat Reclaim
MCHX Microchannel Condenser Coil
LEGEND
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute
for draining.
3. Temperature relief devices located on suction line, liquid line and filter drier of each circuit and have 1/4
flare connection.
4. Chillers with heat reclaim option do not have a pump
package.
5. Dimensions are in mm [inches].
Dimensions (cont)
HR
Heat Reclaim
MCHX Microchannel Condenser Coil
LEGEND
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface.
Side 8 required for coil service area.
2. All pumps have drains located at the
bottom of volute for draining.
3. Temperature relief devices located on
suction line, liquid line and filter drier of
each circuit and have 1/4flare connection.
4. Chillers with heat reclaim option do not
have a pump package.
5. Dimensions are in mm [inches].
a30-4736
33
a30-4737
34
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute for draining.
3. Temperature relief devices located on suction line, liquid line and filter drier
of each circuit and have 1/4flare connection.
4. Chillers with heat reclaim option do not have a pump package.
5. Dimensions are in mm [inches].
HR
MCHX
LEGEND
Heat Reclaim
Microchannel Condenser Coil
Dimensions (cont)
a30-4738
35
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute for draining.
3. Temperature relief devices located on suction line, liquid line and filter drier
of each circuit and have 1/4flare connection.
4. Chillers with heat reclaim option do not have a pump package.
5. Dimensions are in mm [inches].
HR
MCHX
LEGEND
Heat Reclaim
Microchannel Condenser Coil
36
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute for draining.
3. Temperature relief devices located on suction line, liquid line and filter drier
of each circuit and have 1/4flare connection.
4. Chillers with heat reclaim option do not have a pump package.
5. Dimensions are in mm [inches].
HR
MCHX
LEGEND
Heat Reclaim
Microchannel Condenser Coil
Dimensions (cont)
a30-4739
a30-4740
37
NOTES:
1. Unit must have clearances as follows:
Top Do not restrict.
Sides and End 6 from solid surface.
Side 8 required for coil service area.
2. All pumps have drains located at the bottom of volute for draining.
3. Temperature relief devices located on suction line, liquid line and filter drier
of each circuit and have 1/4flare connection.
4. Chillers with heat reclaim option do not have a pump package.
5. Dimensions are in mm [inches].
HR
MCHX
LEGEND
Heat Reclaim
Microchannel Condenser Coil
Selection procedure
Carriers NACO (North American Commericial Operations) Packaged Chiller Builder Program provides quick,
easy selection of Carriers air-cooled liquid chillers. The
program considers specific temperature, fluid and flow
requirements among other factors such as fouling and
altitude corrections.
Before selecting a chiller, consider the following points:
Leaving water (fluid) temperature (LWT)
If the LWT is less than 40 F (4.4 C), loop freeze protection to a minimum of 30 F (16.6 C) below the LWT
set point is required.
If the LWT is to be between 15 F and 30 F (9.4 C and
1.1 C) and the unit size is 30RB060-100, then both
suction line insulation and low ambient head pressure
control must be included. For unit sizes 30RB110-390,
operation below 30 F (1.1 C) is not available.
If the LWT requirement is greater than 60 F (16 C), a
mixing loop is required.
Entering water temperature (EWT)
If the EWT requirement is greater than 70 F (21.1 C), a
mixing loop is required. The EWT cannot exceed 70 F
(21.1 C) for extended operation. Pulldown can be
accomplished from 95 F (35 C).
Cooler flow rate or cooler delta-T
The cooler delta-T must fall between 5 and 20 F (3 and
11 C).
For larger or smaller delta-T applications, a mixing loop
is required.
If the cooler flow is variable, then the rate of change of
flow should not exceed 10% per minute. A loop volume
of greater than 3 gallons per ton (3.25 L per kW) is
recommended.
Cooler pressure drop
A high cooler pressure drop can be expected when the
cooler delta-T is low. A mixing loop can help to alleviate
this situation.
Water quality, fouling factor
Poor water quality can increase the cooler fouling.
Higher than standard fouling factors lead to lower
capacity and higher input kW from a given chiller size
compared to running the same application with better
quality water (and lower fouling factors).
Operation below 32 F (0 C)
Low ambient head pressure control is required.
Consider wind baffles if average wind speed is greater
than 5 mph (8 kph).
Consider higher loop volumes, 6 to 10 gallons per
nominal ton (6.5 to 10.75 L per kW).
Loop freeze protection with glycol is strongly recommended to a minimum of 15 F (8 C) below lowest
anticipated ambient temperature.
Cooler heater option is required if no glycol is used.
Chilled water pump control is strongly recommended;
otherwise override capability is required.
Consider the remote cooler option. Do not bury refrigerant piping.
38
English Example
I Determine 30RB unit size and operating
conditions required to meet given capacity at
given conditions.
Given:
Capacity. . . . . . . . . . . . . . . . . . . . . . . . 126 Tons
Leaving Chilled Water Temp (LCWT) . . . . . . .44 F
Cooler Water Temp Rise . . . . . . . . . . . . . . . 10 F
Condenser Entering Air Temp . . . . . . . . . . . .95 F
Fouling Factor (Cooler) . . . . . . . . . . . . . .0.00010
NOTE: For other than 10 F (5.6 C) temperature
rise, unit selection must be made using the chiller
program in the electronic catalog.
II From Chiller Ratings table on page 54 and
pressure drop curves on page 41, determine
operating data for selected unit.
Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . 30RB130
Capacity. . . . . . . . . . . . . . . . . . . . . . .127.3 Tons
Power Input . . . . . . . . . . . . . . . . . . . . .158.3 kW
Cooler Water Flow . . . . . . . . . . . . . . . 304.3 gpm
Pressure Drop . . . . . . . . . . . . . . . . 12.7 ft of water
SI Example
I Determine unit size and operating conditions
required to meet given capacity at given
conditions.
Given:
Capacity. . . . . . . . . . . . . . . . . . . . . . . . . 270 kW
Leaving Chilled Water Temp (LCWT) . . . . . . . 7 C
Cooler Water Temp Rise . . . . . . . . . . . . . . 5.6 C
Condenser Entering Air Temp . . . . . . . . . . . 35 C
Fouling Factor (Cooler) . . . . . . . . . . . . . . . .0.018
NOTE: For other than approximately 5 to 6 C
temperature rise, unit selection must be made using
the chiller program in the electronic catalog.
II From Chiller Ratings table on page 57 and
pressure drop curves on page 41, determine
operating data for selected unit.
Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . 30RB080
Capacity. . . . . . . . . . . . . . . . . . . . . . . .270.3 kW
Power Input . . . . . . . . . . . . . . . . . . . . . .95.7 kW
Cooler Water Flow . . . . . . . . . . . . . . . . .11.6 L/s
Pressure Drop. . . . . . . . . . . . . . . . . . . . 22.4 kPa
39
060
070
080
090
100
110
120
130
150
160
170
190
PUMP
Hp
Option
Code*
SINGLE PUMP
Impeller Dia.
Rpm
(in.)
Option
Code*
DUAL PUMP
Impeller Dia.
Rpm
(in.)
1750
6.5
Pump
Curve
0,F
1750
6.5
6,M
1,G
1750
7.3
7,N
1750
7.3
8,P
1750
8.15
7.5
2,H
1750
8.15
9,T
3450
5.25
VI
10
3,J
3450
5.4
II
B,Q
3450
5.9
VI
1,G
1750
7.3
7,N
1750
7.3
7.5
2,H
1750
8.15
8,P
1750
8.15
10
3,J
3450
5.4
II
B,Q
3450
5.4
VIIA
15
4,K
3450
6.1
II
C,R
3450
6.0
VIIC
1,G
1750
6.5
IIIA
7.5
2,H
1750
7.4
IIIB
9,T
3450
5.0
VIIB
10
3,J
3450
4.6
IVA
B,Q
3450
4.6
VIIIA
15
4,K
3450
5.2
IVB
C,R
3450
5.2
VIIIB
40
Pump
Curve
50
(149.5kPa)
060, 070
40
dP(Feet)
(119.6kPa)
30
(89.7kPa)
20
(59.8kPa)
10
(29.8kPa)
0
0
100
200
300
400
500
600
700
25.2
31.5
37.8
44.2
GPM
6.3
12.6
18.9
L/s
(179.4kPa)
50
(149.5kPa)
dP(Feet)
40
(119.6kPa)
30
(89.7kPa)
20
(59.8kPa)
10
(29.8kPa)
0
0
200
400
600
800
1000
GPM
12.6
0.0
25.2
37.8
50.5
63.1
L/s
30RB210-300
70
(209.3kPa)
60
(179.4kPa)
dP (Feet)
50
(149.5kPa)
40
(119.6kPa)
30
(89.7kPa)
20
(59.8kPa)
10
(29.8kPa)
0
a30-5389
200
400
0.0
12.6
25.2
600
800
GPM
37.8
50.5
L/s
1000
1200
1400
63.1
75.7
88.3
41
50
(149.5kPa)
ft wg
40
(119.6 kPa)
30
(89.7kPa)
20
(59.8kPa)
10
(29.8kPa)
0
0
100
200
300
400
500
600
700
25.24
31.55
37.85
44.16
GPM
0.00
6.31
12.62
18.93
L/s
a30-4822
HEAT RECLAIM VESSEL PRESSURE DROP CURVES
30RB 120-190 TON
50
(149.5kPa)
40
(119.6 kPa)
30
ft wg
(89.7kPa)
120-150ton
160-190ton
20
(59.8kPa)
10
(29.8kPa)
0
0
100
200
300
400
500
600
700
800
900
1000
37.85
44.16
50.47
56.78
63.09
GPM
0.00
42
6.31
12.62
18.93
25.24
31.55
L/s
a30-4823
40
54
65
73
1750 RPM
78
80
81
(18.3) 60
80
7.50 in
78
(15.2) 50
73
7.00 in
7.5 hp
(12.2) 40 6.50 in
6.00 in
5 hp
(9.1) 30
65%
(6.1) 20
3 hp
N
P
S
H
r
(3.0) 10
(0.0) 0
2 hp
NPSHr
80
160
(0.00)
(5.05)
(10.09)
240
320
400
(15.14)
(20.19)
(25.24)
(gpm)
us
(l/s)
a30-5473
Flow Rate
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
3450 RPM
39
52
62
6.10 in
70
74
(36.6) 120
77
5.40 in
77
77
74
70
(27.4) 90
62
4.50 in
20 hp
(18.3) 60
15 hp
52%
10 hp
N
P
S
H
r
(9.1) 30
(0.0) 0
7.5 hp
5 hp
3 hp
NPSHr
100
200
(0.00)
(6.31)
(12.62)
300
400
500
(18.93)
(25.24)
(31.54)
Flow Rate
(gpm)
us
(l/s)
a30-4388
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
43
8.19 in
35
48
59
1750 RPM
67
73
(18.3) 60
77
78
77
(14.6) 48
73
6.50 in
(11.0) 36
67
15 hp
6.00 in
59%
(7.3) 24
10 hp
7.5 hp
5 hp
N
P
S
H
r
(3.7) 12
3 hp
NPSHr
(0.0) 0
0
160
320
480
640
800
(0.00)
(10.09)
(20.19)
(30.28)
(40.38)
(50.47)
(gpm)
us
(l/s)
a30-4389
Flow Rate
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
PUMP CURVE IIIB FOR HYDRONIC PACKAGE SINGLE PUMP (Fresh Water)
Head Pressure
(m) ft of fluid
(21.3)
70
(18.3)
60
(15.2)
50
(12.2)
40
(9.1)
30
(6.1)
20
(3.0)
10
(0.0)
1750 RPM
N
P
S
H
r
NPSHr
200
400
600
800
(0.00)
(12.62)
(25.24)
(37.85)
(50.47)
(gpm)
us
(l/s)
Flow Rate
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
44
a30-5466
PUMP CURVE IVA FOR HYDRONIC PACKAGE SINGLE PUMP (Fresh Water)
Head Pressure
(m) ft of fluid
(42.7) 140
3450 RPM
(36.6) 120
(30.5) 100
(24.4)
80
(18.3)
60
(12.2)
40
(6.1)
20
(0.0)
N
P
S
H
r
NPSHr
200
400
600
800
1000
(0.00)
(12.62)
(25.24)
(37.85)
(50.47)
(63.09)
(gpm)
us
(l/s)
a30-5468
Flow Rate
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
PUMP CURVE IVB FOR HYDRONIC PACKAGE SINGLE PUMP (Fresh Water)
Head Pressure
(m) ft of fluid
(42.7) 140
3450 RPM
(36.6) 120
(30.5) 100
(24.4)
80
(18.3)
60
(12.2)
40
(6.1)
20
(0.0)
N
P
S
H
r
NPSHr
200
400
600
800
1000
(0.00)
(12.62)
(25.24)
(37.85)
(50.47)
(63.09)
(gpm)
us
(l/s)
Flow Rate
a30-5469
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
45
1750 RPM
39
53
64
72
77
80
80
80
7.30 in
77
(14.6) 48
72
6.50 in
(11.0) 36
64
6.00 in
7.5 hp
53
5 hp
(7.3) 24
3 hp
N
P
S
H
r
(3.7) 12
2 hp
1.5 hp
1 hp
NPSHr
(0.0) 0
0
80
160
240
320
400
(0.00)
(5.05)
(10.09)
(15.14)
(20.19)
(25.24)
(gpm)
us
(l/s)
a30-4391
Flow Rate
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
31
42
52
3450 RPM
60
65
69
70
69
65
(36.6) 120
5.25 in
60
52
15 hp
(27.4) 90
4.50 in
10 hp
7.5 hp
(18.3) 60
5 hp
N
3 hp
(9.1) 30 P
S
H
r
NPSHr
(0.0) 0
0
60
120
(0.00)
(3.79)
(7.57)
Flow Rate
180
240
(11.36)
(15.14)
(gpm)
us
(l/s)
a30-4392
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
46
PUMP CURVE VIIA FOR HYDRONIC PACKAGE DUAL PUMP (Fresh Water)
Head Pressure
(m) ft of fluid
3450 RPM
39
52
62
6.10 in
70
74
77
(36.6) 120
5.40 in
77
77
74
70
(27.4) 90
62
20 hp
(18.3) 60
15 hp
52%
10 hp
N
P
S
H
r
(9.1) 30
(0.0) 0
7.5 hp
5 hp
3 hp
NPSHr
100
200
300
400
500
(0.00)
(6.31)
(12.62)
(18.93)
(25.24)
(31.54)
(gpm)
us
(l/s)
a30-4393
Flow Rate
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
PUMP CURVE VIIB FOR HYDRONIC PACKAGE DUAL PUMP (Fresh Water)
Head Pressure
(m) ft of fluid
(42.7) 140
3450 RPM
(36.6) 120
(30.5) 100
(24.4)
80
(18.3)
60
(12.2)
40
(6.1)
20
(0.0)
N
P
S
H
r
NPSHr
100
200
300
400
500
(0.00)
(6.31)
(12.62)
(18.93)
(25.24)
(31.55)
(gpm)
us
(l/s)
a30-5467
Flow Rate
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
47
3450 RPM
(36.6) 120
(30.5) 100
(24.4)
80
(18.3)
60
(12.2)
40
(6.1)
20
(0.0)
N
P
S
H
r
NPSHr
100
200
300
400
500
(0.00)
(6.31)
(12.62)
(18.93)
(25.24)
(31.55)
(gpm)
us
(l/s)
a30-5472
Flow Rate
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
PUMP CURVE VIIIA FOR HYDRONIC PACKAGE DUAL PUMP (Fresh Water)
Head Pressure
(m) ft of fluid
(42.7) 140
3450 RPM
(36.6) 120
(30.5) 100
(24.4)
80
(18.3)
60
(12.2)
40
(6.1)
(0.0)
N
P
20 S
H
r
NPSHr
200
400
600
800
1000
(0.00)
(12.62)
(25.24)
(37.85)
(50.47)
(63.09)
(gpm)
us
(l/s)
Flow Rate
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
48
a30-5470
PUMP CURVE VIIIB FOR HYDRONIC PACKAGE DUAL PUMP (Fresh Water)
Head Pressure
(m) ft of fluid
(42.7) 140
3450 RPM
(36.6) 120
(30.5) 100
(24.4)
80
(18.3)
60
(12.2)
40
(6.1)
(0.0)
N
P
20 S
H
r
NPSHr
0
0
200
400
600
800
1000
(0.00)
(12.62)
(25.24)
(37.85)
(50.47)
(63.09)
(gpm)
us
(l/s)
a30-5471
Flow Rate
LEGEND
NPSHr Net Positive Suction Head (Pressure) Required
NOTE: Refer to the 30RB nomenclature on page 4 for option identification. Refer to the Pump Impeller Sizes table on page 40 for
more information.
49
90 (27m)
80 (24m)
70 (21m)
60 (18m)
50 (15m)
1
40 (12m)
0
30 (9m)
20 (6m)
10 (3m)
0
0
50
0.00
100
3.15
150
6.31
9.46
200
250
300
350
400
18.93
22.08
25.24
a30-3949
90 (27m)
80 (24m)
70 (21m)
2
60 (18m)
50 (15m)
1
40 (12m)
30 (9m)
20 (6m)
10 (3m)
0
0
50
100
150
0.00
3.15
6.31
9.46
200
250
300
FLOW RATE (GPM)
12.62
15.77
FLOW RATE (L/s)
18.93
350
400
450
500
22.08
25.24
28.39
31.55
a30-3950
NOTE: Refer to the 30RB nomenclature on page 4 for pump envelope curve option identification.
50
130 (39m)
12 0 (36m)
110 (33m)
3
10 0 (30m)
90 (27m)
80 (24m)
70 (21m)
60 (18m)
50 (15m)
40 (12m)
30 (9m)
20 (6m)
10 (3m)
0
0
50
100
150
2 00
250
300
350
400
450
5 00
18.93
22.08
25.24
28.39
31.55
3.15
6.31
9.46
12.62
15.77
FLOW RATE (L/s)
a30-3951
10 0 (30m)
90 (27m)
Available H ead (ft)
3
80 (24m)
70 (21m)
60 (18m)
50 (15m)
40 (12m)
30 (9m)
20 (6m)
10 (3m)
0
0
100
200
300
400
0.00
6.31
12.62
18.93
500
600
700
800
37.85
44.16
50.47
a30-3952
31.55
51
130 (39m)
13
120
12
0 (36m)
110
11
0 (33m)
A vailable
ailable H ead (ft)
100
10
0 (30m)
90 (27m)
80 (24m)
70 (21m)
60 (18m)
50 (15m)
40 (12m)
30 (9m)
20 (6m)
10 (3m)
0
0
0.00
50
100
15
150
200
00
FLOW RATE (GPM)
250
25
300
00
350
3.15
6.31
9.46
12.62
FLOW RATE (L/s)
15.77
18.93
22.08
a30-3953
130 (39m)
13
120
12
0 (36m)
110
11
0 (33m)
Available
ailable H ead (ft)
100
10
0 (30m)
90 (27m)
80 (24m)
70 (21m)
60 (18m)
50 (15m)
40 (12m)
30 (9m)
20 (6m)
10 (3m)
0
50
100
00
150
0.00
3.15
6.31
9.46
200
00
250
300
00
FLOW RATE (GPM)
12.62 15.77 18.93
FLOW RATE (L/s)
350
400
00
22.08
NOTE: Refer to the 30RB nomenclature on page 4 for pump envelope curve option identification.
52
450
500
00
a30-3954
13 0 (39m)
12 0 (36m)
110 (33m)
10 0 (30m)
90 (27m)
80 (24m)
70 (21m)
60 (18m)
50 (15m)
40 (12m)
30 (9m)
20 (6m)
10 (3m)
0
50
100
150
200
250
300
350
400
450
500
22.08
25.24
28.39
31.55
0.00
3.15
6.31
9.46
12.62
15.77
18.93
10 0 (30m)
90 (27m)
80 (24m)
70 (21m)
60 (18m)
50 (15m)
40 (12m)
30 (9m)
20 (6m)
10 (3m)
0
100
200
0.00
6.31
12.62
300
40 0
500
60 0
FLOW RATE (GPM)
18.93
25.24
31.55
37.85
FLOW RATE (L/s)
NOTE: Refer to the 30RB nomenclature on page 4 for pump envelope curve option identification.
7 00
800
9 00
44.16
50.47
56.78
a30-3956
53
Performance data
30RB PACKAGED AIR-COOLED CHILLER RATINGS TABLE ENGLISH
LCWT
(F)
40
42
44
UNIT
SIZE
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
85
Cap.
(Tons)
Input
kW
56.4
65.9
75.0
85.5
94.9
104.6
117.4
125.9
142.8
150.7
164.3
185.9
199.1
211.6
235.0
257.0
279.2
301.4
315.0
328.6
350.2
371.8
58.6
68.4
78.1
88.7
98.4
108.5
121.7
130.6
148.2
156.6
170.6
193.1
206.8
219.6
243.7
266.6
289.6
313.2
327.2
341.1
363.7
386.2
60.8
70.8
81.3
92.0
101.9
112.3
126.0
135.5
153.9
162.7
177.1
200.6
214.7
228.0
252.9
276.6
300.4
325.3
339.8
354.3
377.7
401.2
63.4
74.9
85.1
96.0
107.6
118.3
132.4
142.3
160.7
169.6
186.9
212.8
223.2
240.2
267.3
292.5
319.1
339.2
356.5
373.8
399.7
425.6
64.0
75.7
86.1
96.9
108.5
119.6
133.8
143.7
162.4
171.3
188.8
214.9
225.5
242.8
270.1
295.4
322.2
342.6
360.1
377.6
403.7
429.9
64.8
76.5
87.2
98.1
109.8
121.0
135.4
145.1
164.3
173.0
190.8
217.2
227.9
245.5
273.0
298.5
325.5
346.0
363.8
381.7
408.0
434.4
95
Cooler
Cap.
Flow Rate
(Tons)
(gpm)
134.8
52.9
157.4
61.8
179.2
70.1
204.1
80.3
226.6
89.1
249.7
98.0
280.3
110.3
300.7
118.2
340.9
133.9
359.8
141.6
392.2
154.4
443.8
174.7
475.4
187.2
505.2
198.9
561.1
221.0
613.8
241.8
666.6
262.7
719.6
283.0
752.0
296.0
784.4
309.0
836.0
329.0
887.6
349.0
140.1
55.0
163.3
64.2
186.5
72.9
211.9
83.3
235.2
92.4
259.2
101.8
290.7
114.4
312.2
122.7
354.0
139.1
374.2
147.2
407.5
160.3
461.4
181.5
493.9
194.4
524.7
206.5
582.3
229.3
637.1
250.9
692.0
272.5
748.4
294.4
781.7
307.5
815.1
321.0
868.9
341.8
922.8
363.0
145.3
57.1
169.4
66.5
194.3
76.0
220.1
86.5
243.9
95.8
268.6
105.5
301.3
118.5
324.0
127.3
368.0
144.5
388.9
153.1
423.5
166.5
479.3
188.6
513.2
201.9
545.1
214.4
604.6
238.0
661.3
260.3
718.2
282.7
777.8
306.0
812.4
319.6
847.0
333.0
902.8
355.1
958.5
377.2
LEGEND
LCWT Leaving Chilled Water Temperature
54
Input
kW
69.2
81.9
93.1
104.9
117.6
129.5
144.8
155.4
175.5
185.1
204.1
232.1
243.8
262.5
292.0
319.2
348.1
370.2
389.2
408.2
436.2
464.2
69.8
82.7
94.1
105.7
118.6
130.8
146.1
156.8
177.3
186.9
206.1
234.4
246.2
265.2
294.9
322.3
351.5
373.8
393.0
412.2
440.5
468.8
70.5
83.5
95.3
106.7
119.6
132.2
147.7
158.3
179.3
188.7
208.2
236.7
248.7
268.1
298.0
325.6
354.9
377.4
396.9
416.5
445.0
473.5
120
Input
kW
87.2
103.3
117.6
131.8
148.0
164.0
182.3
195.2
220.2
232.1
256.0
290.7
306.1
329.8
366.4
400.3
436.3
464.2
488.1
512.0
546.7
581.4
87.8
104.2
118.7
132.8
149.1
165.3
183.8
196.8
222.3
234.1
258.3
293.3
308.9
332.9
369.7
403.8
440.1
468.2
492.4
516.7
551.7
586.7
88.5
105.1
119.9
133.7
150.3
166.7
185.4
198.5
224.4
236.1
260.7
296.0
311.7
336.0
373.2
407.5
444.0
472.2
496.8
521.4
556.7
592.0
Cooler
Flow Rate
(gpm)
102.5
120.1
134.1
156.0
173.7
190.2
214.2
229.0
258.7
274.9
299.0
339.7
363.1
385.6
429.1
470.5
512.3
549.8
573.9
598.0
638.7
679.4
106.7
125.0
139.8
162.2
180.5
197.8
222.7
238.2
269.1
286.3
311.1
353.7
378.0
401.2
446.2
489.2
532.7
572.6
597.4
622.3
664.8
707.4
111.0
129.8
145.5
168.6
187.5
205.4
231.3
247.7
279.8
298.1
323.7
368.0
393.1
416.9
463.9
508.6
553.4
596.1
621.7
647.4
691.7
736.1
46
48
50
UNIT
SIZE
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
85
Cap.
(Tons)
Input
kW
63.1
73.4
84.5
95.4
105.5
116.3
130.5
140.5
159.8
168.8
183.8
208.0
222.9
236.6
262.3
286.9
311.5
337.6
352.6
367.6
391.9
416.1
65.5
75.9
87.7
98.9
109.2
120.4
135.0
145.6
165.8
175.1
190.7
215.7
231.2
245.5
272.2
297.6
323.1
350.2
365.8
381.4
406.4
431.5
67.9
78.6
90.7
102.4
113.0
124.6
139.6
150.8
172.1
181.6
197.7
223.7
239.8
254.7
282.3
308.6
335.1
363.2
379.3
395.4
421.4
447.4
65.7
77.6
88.4
99.4
111.2
122.8
137.0
146.5
166.2
174.7
192.9
219.5
230.4
248.3
276.0
301.6
328.8
349.5
367.6
385.8
412.4
438.9
66.6
78.6
90.1
100.8
112.8
124.8
138.6
148.0
168.2
176.5
195.1
221.8
233.0
251.3
279.2
305.0
332.4
353.1
371.6
390.1
416.9
443.7
67.6
79.7
91.8
102.2
114.3
126.8
140.3
149.6
170.4
178.4
197.4
224.3
235.6
254.3
282.5
308.5
336.1
356.8
375.8
394.9
421.7
448.6
95
Cooler
Cap.
Flow Rate
(Tons)
(gpm)
151.0
59.3
175.5
68.9
202.2
79.1
228.3
89.7
252.5
99.2
278.2
109.3
312.1
122.7
336.0
132.0
382.2
150.1
403.8
158.9
439.7
172.8
497.4
195.6
533.1
209.6
566.0
222.7
627.6
246.9
686.2
270.0
745.1
293.2
807.6
317.8
843.5
331.7
879.4
345.6
937.2
368.4
994.9
391.3
156.9
61.6
181.8
71.3
209.9
82.3
236.8
93.0
261.5
102.7
288.2
113.1
323.2
126.9
348.4
136.8
396.9
155.8
419.1
164.9
456.4
179.3
516.4
202.9
553.5
217.7
587.7
231.1
651.5
256.2
712.2
280.1
772.9
304.1
838.2
329.7
875.5
344.2
912.9
358.6
972.8
382.2
1032.7
405.8
162.7
63.8
188.2
73.8
217.1
85.2
245.2
96.3
270.7
106.3
298.3
117.1
334.4
131.3
361.2
141.8
412.1
161.7
434.9
171.0
473.5
186.0
535.7
210.4
574.3
225.9
609.4
239.8
675.5
265.8
738.6
290.5
802.3
315.4
869.9
342.1
908.5
357.0
947.1
371.9
1009.2
396.3
1071.4
420.8
LEGEND
LCWT Leaving Chilled Water Temperature
Input
kW
71.5
84.5
96.5
108.0
121.0
133.8
149.4
159.8
181.3
190.5
210.4
239.1
251.4
271.1
301.1
328.9
358.4
381.0
400.9
420.8
449.5
478.3
72.5
85.6
97.9
109.4
122.6
135.8
151.1
161.4
183.4
192.4
212.7
241.6
254.1
274.2
304.4
332.4
362.1
384.8
405.1
425.4
454.3
483.2
73.4
86.8
99.7
110.9
124.3
138.0
152.9
163.0
185.6
194.4
215.0
244.2
256.9
277.4
307.9
336.0
366.0
388.8
409.4
430.1
459.2
488.3
120
Input
kW
89.2
106.1
121.3
134.7
151.6
168.2
187.0
200.2
226.6
238.2
263.2
298.7
314.6
339.4
376.7
411.2
447.9
476.4
501.4
526.4
561.9
597.4
89.9
107.0
122.6
135.7
152.8
169.6
188.7
202.0
229.0
240.3
265.7
301.4
317.6
342.8
380.5
415.1
452.0
480.6
506.0
531.5
567.2
602.8
90.9
108.0
124.0
137.0
154.1
171.5
190.7
203.8
231.4
242.5
268.4
304.2
320.7
346.4
384.3
419.1
456.3
485.0
510.9
536.7
572.6
608.5
Cooler
Flow Rate
(gpm)
115.5
134.8
151.8
175.4
194.5
213.2
240.1
257.5
291.0
310.1
336.7
382.4
408.8
433.6
482.4
528.5
574.5
620.3
646.8
673.3
719.1
764.9
120.2
139.9
158.2
182.3
201.6
221.2
249.1
267.3
302.6
322.5
349.9
397.1
425.0
450.7
500.8
549.0
596.6
644.9
672.4
699.8
747.0
794.2
125.1
145.1
164.8
189.1
209.0
229.1
258.1
277.5
314.5
335.1
363.5
412.2
441.6
468.3
520.6
569.9
619.3
670.3
698.7
727.0
775.7
824.3
55
55
60
UNIT
SIZE
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
85
Cap.
(Tons)
Input
kW
74.0
85.4
98.4
111.5
122.8
135.3
151.4
163.8
186.1
198.7
215.1
244.5
260.1
275.6
306.7
336.4
366.5
397.5
413.8
430.2
459.6
489.0
75.9
89.2
99.6
115.0
128.2
139.5
159.1
172.2
189.1
206.1
223.0
256.9
266.5
283.4
319.6
353.4
388.0
412.2
429.1
446.1
479.9
513.7
70.0
82.6
96.5
106.0
118.5
132.3
145.2
154.6
179.9
183.4
205.4
230.8
246.7
268.1
295.1
320.4
346.0
366.8
388.8
410.9
436.3
461.7
70.8
84.2
97.2
107.5
120.9
134.6
150.3
159.1
182.1
186.6
209.2
236.4
250.9
273.8
302.2
328.7
355.8
373.2
395.8
418.5
445.7
472.8
95
Cooler
Cap.
Flow Rate
(Tons)
(gpm)
177.4
69.6
204.8
80.3
235.9
92.4
267.3
104.8
294.5
115.5
324.5
127.2
363.1
142.7
392.8
154.5
446.1
175.6
476.4
186.7
515.7
202.6
586.3
230.1
623.7
245.8
661.0
260.5
735.6
289.4
806.7
317.0
879.0
345.3
952.8
373.4
992.1
389.3
1031.4
405.2
1102.0
432.7
1172.6
460.2
182.3
71.0
214.0
83.3
239.0
92.9
276.0
107.4
307.7
119.7
334.7
130.1
381.7
148.9
413.4
161.2
453.8
177.2
494.7
192.8
535.3
208.9
616.5
240.4
639.7
249.6
680.2
265.6
766.9
299.4
848.2
331.2
931.2
363.4
989.3
385.6
1029.9
401.6
1070.6
417.7
1151.8
449.3
1233.0
480.8
LEGEND
LCWT Leaving Chilled Water Temperature
NOTE: Ratings are for standard chillers with no options.
56
Input
kW
76.0
89.8
104.5
114.9
128.7
143.8
157.6
167.5
194.2
199.5
222.8
251.0
266.9
289.4
319.6
347.5
376.4
398.9
422.3
445.6
473.8
502.1
76.7
91.2
105.0
116.2
130.8
145.6
161.9
171.6
195.5
201.6
225.2
254.7
269.8
293.7
324.7
353.2
383.0
403.3
426.8
450.3
479.9
509.4
120
Input
kW
93.6
111.3
127.4
141.1
158.9
177.3
195.6
208.5
237.2
247.8
274.8
311.7
328.5
355.7
394.2
429.6
467.6
495.6
522.6
549.6
586.5
623.4
93.9
112.1
127.4
141.7
160.0
177.6
197.3
210.0
237.2
248.9
275.9
313.7
328.5
355.7
395.7
432.2
471.3
497.8
524.8
551.8
589.5
627.3
Cooler
Flow Rate
(gpm)
147.1
158.0
208.0
222.2
227.6
260.9
297.5
303.8
381.7
401.1
421.7
451.8
511.9
518.4
578.5
632.7
678.8
802.2
822.8
843.4
873.5
903.5
137.2
161.0
179.4
207.8
231.6
250.5
288.6
311.4
343.3
370.9
402.9
462.4
483.0
514.8
578.7
638.7
699.2
741.9
773.8
805.7
865.2
924.7
5.0
6.0
7.0
UNIT
SIZE
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
30.0
Cap.
(kW)
Input
kW
200.9
234.4
267.2
304.1
337.5
372.0
417.6
448.0
508.0
536.7
584.7
661.9
708.9
753.2
836.1
914.6
993.4
1073.5
1121.4
1169.4
1246.5
1323.7
207.8
242.2
276.8
314.3
348.7
384.2
431.1
463.1
525.5
555.5
604.9
685.0
733.2
778.7
864.1
945.3
1026.7
1111.0
1160.5
1209.9
1290.0
1370.0
214.8
250.1
287.2
325.0
359.8
396.5
444.8
478.5
543.7
574.7
625.8
708.5
758.4
805.5
893.3
977.0
1060.9
1149.5
1200.5
1251.6
1334.3
1417.0
64.2
76.0
86.3
97.2
109.0
119.9
134.3
144.2
163.0
171.9
189.5
215.7
226.3
243.6
271.1
296.5
323.4
343.8
361.4
378.9
405.1
431.4
64.9
76.6
87.3
98.2
109.9
121.2
135.6
145.5
164.6
173.4
191.3
217.7
228.4
246.0
273.6
299.2
326.3
346.9
364.7
382.5
408.9
435.4
65.6
77.5
88.3
99.3
111.1
122.5
137.0
146.8
166.3
175.0
193.1
219.7
230.6
248.5
276.3
302.0
329.3
350.0
368.1
386.2
412.8
439.5
35.0
Cooler
Flow Rate
(L/s)
8.6
10.1
11.5
13.0
14.5
16.0
17.9
19.2
21.8
23.0
25.1
28.4
30.4
32.3
35.9
39.2
42.6
46.0
48.1
50.2
53.5
56.8
8.9
10.4
11.9
13.5
15.0
16.5
18.5
19.9
22.6
23.8
26.0
29.4
31.5
33.4
37.1
40.6
44.1
47.7
49.8
51.9
55.4
58.8
9.2
10.7
12.3
14.0
15.5
17.0
19.1
20.5
23.3
24.7
26.9
30.4
32.6
34.6
38.4
42.0
45.6
49.4
51.6
53.7
57.3
60.8
LEGEND
LCWT Leaving Chilled Water Temperature
Cap.
(kW)
Input
kW
189.5
221.3
251.3
287.4
318.9
351.0
394.6
423.1
479.6
507.3
552.7
625.7
670.4
712.1
791.2
865.5
940.2
1014.7
1060.1
1105.5
1178.5
1251.5
196.2
228.7
260.4
297.1
329.5
362.9
407.6
437.5
496.1
525.5
571.9
647.7
693.6
736.3
817.9
894.8
971.8
1050.9
1097.3
1143.8
1219.6
1295.4
203.0
236.3
270.3
307.3
340.2
374.7
420.7
452.1
513.4
544.0
591.7
670.0
717.5
761.9
845.6
924.8
1004.2
1088.0
1135.7
1183.3
1261.7
1340.0
69.5
82.3
93.6
105.3
118.1
130.1
145.5
156.1
176.4
186.0
205.1
233.2
245.0
263.9
293.4
320.8
349.8
371.9
391.0
410.2
438.3
466.4
70.1
83.0
94.6
106.0
119.0
131.3
146.7
157.4
178.1
187.6
206.9
235.3
247.2
266.3
296.1
323.6
352.8
375.2
394.5
413.9
442.3
470.6
70.8
83.8
95.7
107.1
120.0
132.7
148.2
158.8
179.9
189.2
208.9
237.5
249.5
269.0
298.9
326.6
355.9
378.5
398.1
417.8
446.3
474.9
50.0
Input
kW
89.2
105.7
120.4
134.8
151.3
167.8
186.5
199.6
225.3
237.4
261.9
297.4
313.2
337.5
374.8
409.4
446.3
474.8
499.3
523.8
559.3
594.8
89.8
106.5
121.5
135.6
152.4
169.1
187.9
201.1
227.2
239.2
264.0
299.8
315.7
340.3
377.9
412.7
449.7
478.4
503.2
528.0
563.8
599.5
90.4
107.4
122.6
136.5
153.5
170.3
189.3
202.7
229.1
241.0
266.2
302.2
318.3
343.2
381.0
416.0
453.3
482.1
507.3
532.4
568.4
604.4
Cooler
Flow Rate
(L/s)
6.5
7.6
8.4
9.8
11.0
12.0
13.5
14.4
16.3
17.3
18.8
21.4
22.9
24.3
27.0
29.6
32.3
34.7
36.2
37.7
40.3
42.8
6.7
7.8
8.8
10.2
11.3
12.4
14.0
14.9
16.9
18.0
19.5
22.2
23.7
25.2
28.0
30.7
33.4
36.0
37.5
39.0
41.7
44.4
6.9
8.1
9.1
10.5
11.7
12.8
14.5
15.5
17.5
18.6
20.2
23.0
24.6
26.1
29.0
31.8
34.6
37.3
38.9
40.5
43.2
46.0
57
8.0
10.0
UNIT
SIZE
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
30RB060
30RB070
30RB080
30RB090
30RB100
30RB110
30RB120
30RB130
30RB150
30RB160
30RB170
30RB190
30RB210
30RB225
30RB250
30RB275
30RB300
30RB315
30RB330
30RB345
30RB360
30RB390
30.0
Cap.
(kW)
Input
kW
222.2
258.0
297.4
335.7
371.3
409.1
458.9
494.2
562.2
594.1
646.9
732.1
784.4
832.8
923.4
1009.6
1096.2
1188.2
1240.9
1293.7
1378.9
1464.1
237.2
274.4
316.8
357.7
394.9
435.1
487.7
526.8
601.1
634.6
690.8
781.4
837.9
889.9
986.4
1078.3
1170.8
1269.2
1325.4
1381.6
1472.2
1562.8
66.4
78.4
89.5
100.5
112.5
124.2
138.5
148.1
168.0
176.6
195.0
221.8
232.9
251.1
279.0
304.9
332.4
353.2
371.6
390.0
416.8
443.6
68.1
80.4
92.6
103.0
115.3
127.9
141.5
150.9
171.8
179.9
199.1
226.2
237.7
256.5
284.9
311.1
339.0
359.8
379.0
398.1
425.2
452.3
35.0
Cooler
Flow Rate
(L/s)
9.5
11.1
12.8
14.4
16.0
17.6
19.7
21.2
24.2
25.5
27.8
31.4
33.7
35.8
39.7
43.4
47.1
51.1
53.3
55.6
59.2
62.9
10.2
11.8
13.6
15.4
17.0
18.7
21.0
22.7
25.9
27.3
29.7
33.6
36.0
38.2
42.4
46.3
50.3
54.6
57.0
59.4
63.3
67.2
Cap.
(kW)
Input
kW
210.0
243.8
280.2
317.5
351.1
386.6
434.0
467.1
531.3
562.4
611.7
692.4
742.2
788.3
874.1
955.7
1037.7
1124.9
1174.1
1223.3
1304.1
1384.8
224.3
259.4
299.2
338.3
373.4
411.3
461.4
498.1
568.3
601.0
653.5
739.2
793.7
842.4
933.8
1020.8
1108.3
1202.0
1254.5
1306.9
1392.7
1478.4
71.7
84.7
96.8
108.3
121.3
134.1
149.7
160.1
181.7
190.9
210.9
239.6
251.9
271.7
301.8
329.6
359.1
381.8
401.8
421.7
450.5
479.2
73.4
86.8
99.7
110.9
124.3
138.0
152.9
163.0
185.6
194.4
215.0
244.2
256.9
277.4
307.9
336.0
366.0
388.8
409.4
430.1
459.2
488.3
LEGEND
LCWT Leaving Chilled Water Temperature
NOTE: Ratings are for standard chillers with no options.
58
50.0
Cap.
(kW)
Input
kW
167.4
195.4
219.7
254.3
281.9
308.9
347.8
373.0
421.5
449.5
487.8
554.3
592.4
628.2
698.7
765.9
832.9
899.0
937.3
975.5
1042.1
1108.7
179.8
208.5
236.5
271.9
300.5
329.4
371.0
398.7
451.6
481.6
522.2
592.4
634.5
672.8
748.0
819.2
890.4
963.2
1003.8
1044.3
1114.6
1184.9
91.0
108.2
123.8
137.4
154.6
171.6
190.8
204.2
231.2
242.9
268.5
304.6
320.9
346.2
384.3
419.5
456.9
485.9
511.4
536.9
573.1
609.3
92.5
110.0
126.3
139.4
156.9
174.6
194.1
207.5
235.5
246.8
273.1
309.7
326.5
352.6
391.2
426.6
464.5
493.7
520.0
546.3
582.8
619.3
Cooler
Flow Rate
(L/s)
7.2
8.4
9.4
10.9
12.1
13.3
14.9
16.0
18.1
19.3
21.0
23.8
25.5
27.0
30.0
32.9
35.8
38.6
40.3
41.9
44.8
47.6
7.7
9.0
10.2
11.7
12.9
14.2
16.0
17.2
19.4
20.7
22.5
25.5
27.3
28.9
32.2
35.2
38.3
41.4
43.2
44.9
47.9
51.0
FIELD
POWER
SUPPLY
VALVE
PRESSURE
GAGE
VIBRATION
ELIMINATOR
STRAINER
GATE
VALVE
SHUT OFF
VALVES
BALANCING VALVE
NOTES:
1. Chiller must be installed level
to maintain proper compresTO
sor oil return.
EXPANSION
2.
Piping
shown are general
TANK
points-of-connection
guides
only and are not intended for a
specific installation. Wiring and
piping shown are for a quick
overview of system and are not
in accordance with recognized
standards.
3. All wiring must comply with
applicable local and national
codes.
4. All piping must follow standard
piping techniques. Refer to
Carrier System Design Manual
or
appropriate
ASHRAE
(American Society of Heating,
Refrigerating, and Air Conditioning Engineers) handbook
for details.
FLOW
PUMP
DRAIN
a30-4373
LEGEND
Airflow Through Condenser
Power Wiring
Chilled Water Piping
NOTES:
1. Chiller must be installed level to
maintain proper compressor oil
return.
2. Wiring and piping shown are general points-of-connection guides
only and are not intended for a specific installation. Wiring and piping
shown are for a quick overview of
system and are not in accordance
with recognized standards.
3. All wiring must comply with applicable local and national codes.
4. All piping must follow standard piping techniques. Refer to Carrier
System Design Manual or appropriate ASHRAE (American Society of
Heating, Refrigerating, and Air Conditioning Engineers) handbook for
details.
5. Air separator required as close to
chiller as possible (except primary/
secondary systems).
6. Additional 20 mesh strainer required
for open loop systems.
7. A field-installed expansion tank is
required.
STRAINER
SEE NOTE 6
COMBINATION
VALVE
a30-4374
59
NOTES:
1. Chiller must be installed level to
maintain proper compressor oil
return.
2. Piping shown are general pointsof-connection guides only and are
not intended for a specific installation. Wiring and piping shown are
for a quick overview of system and
are not in accordance with recognized standards.
3. All wiring must comply with applicable local and national codes.
4. All piping must follow standard piping techniques. Refer to Carrier
System Design Manual or appropriate ASHRAE (American Society of Heating, Refrigerating, and
Air Conditioning Engineers) handbook for details.
RETURN
a30-4730
a30-4731
60
Heater (Optional)
D
FS
PP
T1
T2
V
PP T2
T1 FS PP
LEGEND
Drain, 3/4-in. NPT
Flow Switch
Pipe Plug, 1/4-in. NPT
Leaving Water Thermistor
Entering Water Thermistor
Vent, 1/4-in. NPT
Chilled Water
Out
Chilled Water
In
a30-5302
TYPICAL PIPING DIAGRAM FOR 30RB UNITS WITH HYDRONIC PACKAGE SINGLE PUMP
D
Heater (Optional)
PP T2
T1 FS PP
PT
INSIDE
UNIT
PT
D
PT
OUTSIDE
UNIT
Chilled
Water Out
PT
PT
Heater
D
D
E
FS
PP
PT
T1
T2
V
LEGEND
Drain, 3/4-in. NPT
Drain, 1/4-in. NPT
Expansion Tank Connection, 3/4-in. NPT
Flow Switch
Pipe Plug, 1/4-in. NPT
Pressure/Temperature Tap
Leaving Water Thermistor
Entering Water Thermistor
Vent, 1/4-in. NPT
Indicates items provided with the
optional hydronic pump package.
Pump
Combination Valve
Pressure Relief*
Isolation Valve*
Flexible Connections*
Pressure Reducing
Fill Valve*
a30-5303
20 Mesh Stainer**
61
Heater (Optional)
PP T2
T1 FS PP
INSIDE
UNIT
OUTSIDE
UNIT
Chilled
Water Out
PT
PT
D
Heater
Chilled
Water In
D
D
E
FS
PP
PT
T1
T2
V
LEGEND
Drain, 3/4-in. NPT
Drain, 1/4-in. NPT
Expansion Tank Connection, 3/4-in. NPT
Flow Switch
Pipe Plug, 1/4-in. NPT
Pressure/Temperature Tap
Leaving Water Thermistor
Entering Water Thermistor
Vent, 1/4-in. NPT
Indicates items provided with the
optional hydronic pump package.
62
Strainer/Suction Guide
Isolation Valve*
Pressure Reducing
Fill Valve*
20 Mesh Stainer**
a30-5304
TYPICAL PIPING DIAGRAM FOR 30RB UNITS WITH HEAT RECLAIM OPTION
T1 FS PP
HEAT
RECLAIM
SUPPLY
PP T2
Flexible Connections*
HEAT
RECLAIM
RETURN
Pump*
D
FS
PP
R
T1
T2
V
LEGEND
Drain, Field Supplied
Flow Switch
Pipe Plug, 1/4-in. NPT
Pressure Relief
Leaving Water Thermistor
Entering Water Thermistor
Vent, Field Supplied
Isolation Valve*
20 Mesh Stainer*
Three-Way Valve*
a30-4741
63
Electrical data
30RB ELECTRICAL DATA SINGLE POINT UNITS
UNIT 30RB
060
070
080
090
100
110
120
130
150
160
170
190
210
225
250
275
300
UNIT VOLTAGE
Supplied
Min
Max
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
V-Hz (3 Ph)
LEGEND
ICF Instantaneous Current Flow MOCP
MCA Minimum Circuit Amps
XL
MCA
XL
291.5
150.9
127.9
102.4
334.7
175.5
147.9
119.8
366.5
189.3
160.6
128.6
433.6
226.9
191.4
154.6
472.0
248.7
209.2
170.0
508.6
265.3
224.1
180.8
578.1
304.6
256.2
208.2
626.7
327.7
276.5
223.3
684.3
360.4
303.2
246.4
744.8
390.1
328.9
265.9
802.4
422.8
355.6
289.0
920.5
485.2
408.0
331.5
501.8
422.9
342.3
534.5
449.6
365.4
596.8
502.0
408.0
659.2
554.4
450.5
721.6
606.8
493.0
NO HYDRONIC PACKAGE
MOCP
ICF
Rec Fuse
Size
XL
XL
350
682.8
350
175
362.9
175
150
302.0
150
125
244.7
110
400
777.0
400
200
428.8
200
175
355.9
175
150
287.4
150
400
757.8
400
225
401.3
200
175
334.7
175
150
270.9
150
500
875.9
500
250
480.3
250
225
399.4
225
175
322.2
175
500
914.3
500
250
502.1
250
250
417.2
225
200
337.6
200
600
950.9
600
300
518.7
300
250
432.1
250
200
348.4
200
600
1020.4
600
350
538.0
350
300
464.2
300
225
325.8
225
700
1068.9
700
350
581.1
350
300
484.5
300
250
391.0
250
700
1126.5
700
400
613.8
400
350
511.2
350
250
414.1
250
800
1187.0
800
400
643.5
400
350
536.9
350
300
433.5
300
1000
1244.6
1000
450
676.2
450
400
563.6
400
300
456.6
300
1000
1362.7
1000
500
738.5
500
450
616.0
450
350
499.1
350
600
755.1
600
450
630.9
450
350
509.9
350
600
787.8
600
450
657.6
450
400
533.0
400
600
850.2
600
600
710.0
600
450
575.6
450
700
912.6
700
600
762.4
600
500
618.1
500
800
975.0
800
700
814.8
700
500
660.7
500
NOTES:
1. Units are suitable for use on electrical systems where voltage supplied to the unit terminals
is not below or above the listed minimum and maximum limits. Maximum allowable phase
imbalance is: voltage, 2%; amps 10%.
2. All units or modules have single point primary power connection. (Each unit or module
requires its own power supply.) Main power must be supplied from a field-supplied
disconnect.
3. Cooler heater is wired into the control circuit so it is always operable as long as the power
supply disconnect is on, even if any safety device is open.
4. For MCA that is less than or equal to 380 amps, 3 conductors are required.
For MCA between 381 and 760 amps, 6 conductors are required.
For MCA between 761 and 1140 amps, 9 conductors are required.
For MCA between 1141 and 1520 amps, 12 conductors are required.
Calculation of conductors required is based on 75 C copper wire.
MCA
XL
300.6
156.0
132.1
105.7
343.8
180.8
152.1
123.1
MCA
XL
306.9
159.0
135.0
107.8
350.1
183.6
155.0
125.2
381.9
197.4
167.7
134.0
449.0
235.0
198.5
160.0
487.4
256.8
216.3
175.4
524.0
273.4
231.2
186.2
593.5
312.7
263.3
213.6
642.1
335.8
283.6
228.7
699.7
368.5
310.3
251.8
760.2
398.2
336.0
271.3
817.8
430.9
362.7
294.4
935.9
493.3
415.1
336.9
5. Wiring for main field supply must be rated 75 C minimum. Use copper for all units.
a. Incoming wire size range for the terminal block is no. 4 AWG (American Wire Gage) to
500 kcmil.
b. Incoming wire size range of non-fused disconnect with MCA up to 599.9 amps is 3/0 to
500 kcmil.
c. Incoming wire size range of non-fused disconnect with MCA from 600 to 799.9 amps is
1/0 to 500 kcmil.
d. Incoming wire size range of non-fused disconnect with MCA from 800 to 1199.9 amps is
250 kcmil to 500 kcmil.
6. Hydronic pump packages are not available as a factory-installed option for units
30RB210-390.
7. Power draw includes both crankcase heaters and cooler heaters (where used). Each compressor has a crankcase heater which draws 56 watts of power. Units ordered with the
cooler heater option have 1 (060-150) or 2 (160-300) cooler heaters, 825 watts each.
208/230
460
575 v only
64
A
315
B
A
330
B
A
345
B
A
360
B
A
390
B
UNIT VOLTAGE
Supplied
Min
Max
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
V-Hz (3 Ph)
LEGEND
ICF Instantaneous Current Flow MOCP
MCA Minimum Circuit Amps
XL
MCA
XL
744.8
390.1
328.9
265.9
744.8
390.1
328.9
265.9
802.4
422.8
355.6
289.0
744.8
390.1
328.9
265.9
802.4
422.8
355.6
289.0
802.4
422.8
355.6
289.0
920.5
485.2
408.0
331.5
802.4
422.8
355.6
289.0
920.5
485.2
408.0
331.5
920.5
485.2
408.0
331.5
NO HYDRONIC PACKAGE
MOCP
ICF
Rec Fuse
Size
XL
XL
800
1187.0
800
400
643.5
400
350
536.9
350
300
433.5
300
800
1187.0
800
400
643.5
400
350
536.9
350
300
433.5
300
1000
1244.6
1000
450
676.2
450
400
563.6
400
300
456.6
300
800
1187.0
800
400
643.5
400
350
536.9
350
300
433.5
300
1000
1244.6
1000
450
676.2
450
400
563.6
400
300
456.6
300
1000
1244.6
1000
450
676.2
450
400
563.6
400
300
456.6
300
1000
1362.7
1000
500
738.5
500
450
616.0
450
350
499.1
350
1000
1244.6
1000
450
676.2
450
400
563.6
400
300
456.6
300
1000
1362.7
1000
500
738.5
500
450
616.0
450
350
499.1
350
1000
1362.7
1000
500
738.5
500
450
616.0
450
350
499.1
350
NOTES:
1. Units are suitable for use on electrical systems where voltage supplied to the unit terminals
is not below or above the listed minimum and maximum limits. Maximum allowable phase
imbalance is: voltage, 2%; amps 10%.
2. All units or modules have single point primary power connection. (Each unit or module
requires its own power supply.) Main power must be supplied from a field-supplied
disconnect.
3. Cooler heater is wired into the control circuit so it is always operable as long as the power
supply disconnect is on, even if any safety device is open.
4. For MCA that is less than or equal to 380 amps, 3 conductors are required.
For MCA between 381 and 760 amps, 6 conductors are required.
For MCA between 761 and 1140 amps, 9 conductors are required.
For MCA between 1141 and 1520 amps, 12 conductors are required.
Calculation of conductors required is based on 75 C copper wire.
MCA
XL
MCA
XL
5. Wiring for main field supply must be rated 75 C minimum. Use copper for all units.
a. Incoming wire size range for the terminal block is no. 4 AWG (American Wire Gage) to
500 kcmil.
b. Incoming wire size range of non-fused disconnect with MCA up to 599.9 amps is 3/0 to
500 kcmil.
c. Incoming wire size range of non-fused disconnect with MCA from 600 to 799.9 amps is
1/0 to 500 kcmil.
d. Incoming wire size range of non-fused disconnect with MCA from 800 to 1199.9 amps is
250 kcmil to 500 kcmil.
6. Hydronic pump packages are not available as a factory-installed option for units
30RB210-390.
7. Power draw includes both crankcase heaters and cooler heaters (where used). Each compressor has a crankcase heater which draws 56 watts of power. Units ordered with the
cooler heater option have 1 (060-150) or 2 (160-300) cooler heaters, 825 watts each.
208/230
460
575 v only
65
060
070
080
090
100
110
120
130
150
160
170
190
UNIT VOLTAGE
Supplied
Min
Max
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
V-Hz (3 Ph)
LEGEND
ICF Instantaneous Current Flow MOCP
MCA Minimum Circuit Amps
XL
NOTES:
1. Units are suitable for use on electrical systems where voltage supplied to the unit terminals
is not below or above the listed minimum and maximum limits. Maximum allowable phase
imbalance is: voltage, 2%; amps 10%.
2. All units and modules have single point primary power connection. (Each unit or module
requires its own power supply.) Main power must be supplied from a field-supplied
disconnect.
3. Cooler heater is wired into the control circuit so it is always operable as long as the power
supply disconnect is on, even if any safety device is open.
4. For MCA that is less than or equal to 380 amps, 3 conductors are required.
For MCA between 381 and 760 amps, 6 conductors are required.
For MCA between 761 and 1140 amps, 9 conductors are required.
For MCA between 1141 and 1520 amps, 12 conductors are required.
Calculation of conductors required is based on 75 C copper wire.
MCA
XL
316.5
164.9
139.4
111.6
359.7
189.5
159.4
129.0
391.5
203.3
172.1
137.8
458.6
240.9
202.9
163.8
497.0
262.7
220.7
179.2
533.6
279.3
235.6
190.0
603.1
318.6
267.7
217.4
651.7
341.7
288.0
232.5
709.3
374.4
314.7
255.6
769.8
404.1
340.4
275.1
827.4
436.8
367.1
298.2
945.5
499.2
419.5
340.7
MCA
XL
403.2
210.3
177.6
142.6
470.3
247.9
208.4
168.6
508.7
269.7
226.2
184.0
545.3
286.3
241.1
194.8
614.8
325.6
273.2
222.2
663.4
348.7
293.5
237.3
721.0
381.4
320.2
260.4
781.5
411.1
345.9
279.9
839.1
443.8
372.6
303.0
957.2
506.2
425.0
345.5
5. Wiring for main field supply must be rated 75 C minimum. Use copper for all units.
a. Incoming wire size range for the terminal block is no. 4 AWG (American Wire Gage) to
500 kcmil.
b. Incoming wire size range of non-fused disconnect with MCA up to 599.9 amps is 3/0 to
500 kcmil.
c. Incoming wire size range of non-fused disconnect with MCA from 600 to 799.9 amps is
1/0 to 500 kcmil.
d. Incoming wire size range of non-fused disconnect with MCA from 800 to 1199.9 amps is
250 kcmil to 500 kcmil.
6. Hydronic pump packages are not available as a factory-installed option for units
30RB210-390.
7. Power draw includes both crankcase heaters and cooler heaters (where used). Each compressor has a crankcase heater which draws 56 watts of power. Units ordered with the
cooler heater option have 1 (060-150) or 2 (160-300) cooler heaters, 825 watts each.
208/230
460
575 v only
66
450
807.6
450
225
428.5
225
200
357.2
200
150
288.9
150
500
925.7
500
250
507.5
300
250
421.9
225
200
340.2
200
600
964.1
600
300
529.3
300
250
439.7
250
200
355.6
200
600
1000.7
600
300
545.9
300
250
454.6
250
225
366.4
225
700
1070.2
700
350
585.2
350
300
486.7
300
250
393.8
250
700
1118.7
700
350
608.3
400
300
507.0
300
250
409.0
250
800
1176.3
800
400
641.0
400
350
533.7
350
300
432.1
300
800
1236.8
800
450
670.7
450
350
559.4
400
300
451.5
300
1000
1294.4
1000
450
703.4
500
400
586.1
400
350
474.6
350
1000
1412.5
1000
600
765.7
600
450
638.5
450
350
517.1
350
060
070
080
090
100
110
120
130
150
160
170
190
210
225
250
275
300
ICF
UNIT VOLTAGE
Supplied
MCA
NO HYDRONIC PACKAGE
MOCP
ICF
V-Hz
(3 Ph)
Min
Max
XL
XL
XL
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
187
342
414
518
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
253
418
506
633
168.8/141.5
86.4/ 74.1
73.6/ 62.5
59.0/ 50.0
212.0/141.5
110.9/ 74.1
93.6/ 62.5
76.3/ 50.0
216.5/168.8
112.5/ 86.4
95.2/ 73.6
76.2/ 59.0
283.6/168.8
150.1/ 86.4
126.0/ 73.6
102.2/ 59.0
283.6/212.0
150.1/110.9
126.0/ 93.6
102.2/ 76.3
283.6/243.8
150.1/124.8
126.0/106.3
102.2/ 85.2
295.5/306.2
156.7/160.2
131.4/135.2
106.5/110.2
401.7/243.8
212.5/124.8
178.4/106.3
144.7/ 85.2
401.7/306.2
212.5/160.2
178.4/135.2
144.7/110.2
519.8/243.8
274.9/124.8
230.8/106.3
187.3/ 85.2
519.8/306.2
274.9/160.2
230.8/135.2
187.3/110.2
543.7/400.4
288.0/209.5
241.6/176.8
195.9/144.1
626.7/353.9
327.7/186.4
233.3/200.0
188.8/162.0
684.3/353.9
360.4/186.4
260.0/200.0
211.9/162.0
684.3/472.0
360.4/248.7
303.2/209.2
246.4/170.0
920.5/353.9
485.2/186.4
408.0/156.8
331.5/127.5
920.5/472.0
485.2/248.7
408.0/209.2
331.5/170.0
225/200
110/110
100/ 90
80/ 70
300/200
150/110
125/ 90
110/ 70
250/225
150/110
125/100
100/ 80
350/225
175/110
150/100
125/ 80
350/300
175/150
150/125
125/110
350/300
175/150
150/125
125/110
350/400
200/200
150/175
125/125
450/300
250/150
200/125
175/110
450/400
250/200
200/175
175/125
600/300
300/150
250/125
200/110
600/400
300/200
250/175
200/125
600/450
300/250
250/200
225/175
700/400
350/225
250/225
200/175
700/400
400/225
300/225
225/175
700/500
400/250
350/250
250/200
1000/400
500/225
450/175
350/150
1000/500
500/250
450/250
350/200
560.0/532.8
298.4/286.1
247.7/236.6
201.2/192.3
654.2/532.8
364.3/286.1
301.6/236.6
243.9/192.3
607.8/560.0
324.5/298.4
269.3/247.7
218.5/201.2
725.9/560.0
403.5/298.4
334.0/247.7
269.8/201.2
725.9/654.2
403.5/364.3
334.0/301.6
269.8/243.9
725.9/635.0
403.5/336.8
334.0/280.4
269.8/227.4
737.8/748.4
410.1/413.6
339.4/343.2
274.1/277.8
843.9/635.0
465.9/336.8
386.4/280.4
312.4/227.4
843.9/748.4
465.9/413.6
386.4/343.2
312.4/277.8
962.0/635.0
528.3/336.8
438.8/280.4
354.9/227.4
962.0/748.4
528.3/413.6
438.8/343.2
354.9/277.8
985.9/842.6
541.3/462.9
449.6/384.8
363.5/311.7
1068.9/796.2
581.1/439.7
441.3/408.0
356.4/329.6
1126.5/796.2
613.8/439.7
468.0/408.0
379.5/329.6
1126.5/914.3
613.8/502.1
511.2/417.2
414.1/337.6
1362.7/796.2
738.5/439.7
616.0/364.8
499.1/295.1
1362.7/914.3
738.5/502.1
616.0/417.2
499.1/337.6
Rec
Fuse
Size
200/175
100/ 90
90/ 80
70/ 60
250/175
125/ 90
110/ 80
90/ 60
250/200
125/100
110/ 90
90/ 70
350/200
175/100
150/ 90
125/ 70
350/250
175/125
150/110
125/ 90
350/300
175/150
150/125
125/100
350/350
175/175
150/150
125/125
450/300
225/150
200/125
175/100
450/350
225/175
200/150
175/125
600/300
300/150
250/125
200/100
600/350
300/175
250/150
200/125
600/450
300/225
250/200
225/175
700/400
350/200
250/225
200/175
700/400
400/200
300/225
225/175
700/500
400/250
350/225
250/200
1000/400
500/200
450/175
350/150
1000/500
500/250
450/225
350/200
LEGEND
MOCP Maximum Overcurrent Protection
(Ckt1/Ckt2)
XL
Across-the-Line Start
NOTES:
1. Units are suitable for use on electrical systems where voltage supplied to the unit terminals
is not below or above the listed minimum and maximum limits. Maximum allowable phase
imbalance is: voltage, 2%; amps 10%.
2. Control power is derived from main power. No separate control power connection is
required.
3. Cooler heater is wired into the control circuit so it is always operable as long as the power
supply disconnect is on, even if any safety device is open.
4. For MCA that is less than or equal to 380 amps, 3 conductors are required.
For MCA between 381 and 760 amps, 6 conductors are required.
For MCA between 761 and 1140 amps, 9 conductors are required.
For MCA between 1141 and 1520 amps, 12 conductors are required.
Calculation of conductors required is based on 75 C copper wire.
MCA
XL
XL
XL
177.9/141.5
91.5/ 74.1
77.8/ 62.5
62.3/ 50.0
221.1/141.5
116.0/ 74.1
97.8/ 62.5
79.6/ 50.0
250/200
125/110
110/ 90
80/ 70
300/200
150/110
125/ 90
110/ 70
570.8/532.8
304.3/286.1
252.6/236.6
205.1/192.3
665.0/532.8
370.2/286.1
306.5/236.6
247.8/192.3
Rec
Fuse
Size
200/175
110/ 90
90/ 80
70/ 60
250/175
150/ 90
110/ 80
90/ 60
MCA
XL
XL
XL
184.2/141.5
94.5/ 74.1
80.7/ 62.5
64.4/ 50.0
227.4/141.5
119.0/ 74.1
100.7/ 62.5
81.7/ 50.0
231.9/168.8
120.6/ 86.4
102.3/ 73.6
81.6/ 59.0
299.0/168.8
158.2/ 86.4
133.1/ 73.6
107.6/ 59.0
299.0/212.0
158.2/110.9
133.1/ 93.6
107.6/ 76.3
299.0/243.8
158.2/124.8
133.1/106.3
107.6/ 85.2
310.9/306.2
164.8/160.2
138.5/135.2
111.9/110.2
417.1/243.8
220.6/124.8
185.5/106.3
150.1/ 85.2
417.1/306.2
220.6/160.2
185.5/135.2
150.1/110.2
535.2/243.8
283.0/124.8
237.9/106.3
192.7/ 85.2
535.2/306.2
283.0/160.2
237.9/135.2
192.7/110.2
559.1/400.4
296.1/209.5
248.7/176.8
201.3/144.1
250/200
125/110
110/ 90
90/ 70
300/200
150/110
125/ 90
110/ 70
300/225
150/110
125/100
100/ 80
350/225
200/110
150/100
125/ 80
350/300
200/150
150/125
125/110
350/300
200/150
150/125
125/110
400/400
200/200
175/175
125/125
500/300
250/150
225/125
175/110
500/400
250/200
225/175
175/125
600/300
300/150
250/125
225/110
600/400
300/200
250/175
225/125
600/450
300/250
250/200
225/175
577.7/532.8
308.1/286.1
255.7/236.6
207.6/192.3
671.9/532.8
374.0/286.1
309.6/236.6
250.3/192.3
625.5/560.0
334.2/298.4
277.3/247.7
224.9/201.2
743.5/560.0
413.2/298.4
342.0/247.7
276.2/201.2
743.5/654.2
413.2/364.3
342.0/301.6
276.2/243.9
743.5/635.0
413.2/336.8
342.0/280.4
276.2/227.4
755.5/748.4
419.7/413.6
347.4/343.2
280.5/277.8
861.6/635.0
475.6/336.8
394.4/280.4
318.8/227.4
861.6/748.4
475.6/413.6
394.4/343.2
318.8/277.8
979.7/635.0
538.0/336.8
446.8/280.4
361.3/227.4
979.7/748.4
538.0/413.6
446.8/343.2
361.3/277.8
1003.6/842.6
551.0/462.9
457.6/384.8
369.9/311.7
Rec
Fuse
Size
225/175
110/ 90
90/ 80
80/ 60
300/175
150/ 90
125/ 80
100/ 60
300/200
150/100
125/ 90
90/ 70
350/200
175/100
150/ 90
125/ 70
350/250
175/125
150/110
125/ 90
350/300
175/150
150/125
125/100
350/350
200/175
150/150
125/125
450/300
250/150
200/125
175/100
450/350
250/175
200/150
175/125
600/300
300/150
250/125
225/100
600/350
300/175
250/150
225/125
600/450
300/225
250/200
225/175
5. Wiring for main field supply must be rated 75 C minimum. Use copper for all units.
a. Incoming wire size range for the terminal block is no. 4 AWG (American Wire Gage) to
500 kcmil.
b. Incoming wire size range of non-fused disconnect with MCA up to 599.9 amps is 3/0 to
500 kcmil.
c. Incoming wire size range of non-fused disconnect with MCA from 600 to 799.9 amps is
1/0 to 500 kcmil.
d. Incoming wire size range of non-fused disconnect with MCA from 800 to 1199.9 amps is
250 kcmil to 500 kcmil.
6. Hydronic pump packages are not available as a factory-installed option for units
30RB210-390.
7. Power draw includes both crankcase heaters and cooler heaters (where used). Each compressor has a crankcase heater which draws 56 watts of power. Units ordered with the
cooler heater option have 1 (060-150) or 2 (160-300) cooler heaters, 825 watts each.
208/230
460
575 v only
67
A
315
B
A
330
B
A
345
B
A
360
B
A
390
B
ICF
UNIT VOLTAGE
Supplied
Min
Max
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
460-60
414
506
575-60
518
633
380-60
342
418
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
208/230-60
187
253
380-60
342
418
460-60
414
506
575-60
518
633
V-Hz (3 Ph)
NO HYDRONIC PACKAGE
MCA
MOCP
ICF
Rec Fuse
Size
XL
XL
XL
519.8/243.8 600/300 962.0/635.0 600/300
274.9/124.8 300/150 528.3/336.8 300/150
230.8/106.3 250/125 438.8/280.4 250/125
187.3/ 85.2 200/110 354.9/227.4 200/100
519.8/243.8 600/300 962.0/635.0 600/300
230.8/106.3 250/125 438.8/280.4 250/125
187.3/ 85.2 200/110 354.9/227.4 200/100
274.9/124.8 300/150 528.3/336.8 300/150
519.8/306.2 600/400 962.0/748.4 600/350
274.9/160.2 300/200 528.3/413.6 300/175
230.8/135.2 250/175 438.8/343.2 250/150
187.3/110.2 200/125 354.9/277.8 200/125
519.8/243.8 600/300 962.0/635.0 600/300
274.9/124.8 300/150 528.3/336.8 300/150
230.8/106.3 250/125 438.8/280.4 250/125
187.3/ 85.2 200/110 354.9/227.4 200/100
519.8/306.2 600/400 962.0/748.4 600/350
274.9/160.2 300/200 528.3/413.6 300/175
230.8/135.2 250/175 438.8/343.2 250/150
187.3/110.2 200/125 354.9/277.8 200/125
519.8/306.2 600/400 962.0/748.4 600/350
274.9/160.2 300/200 528.3/413.6 300/175
230.8/135.2 250/175 438.8/343.2 250/150
187.3/110.2 200/125 354.9/277.8 200/125
543.7/400.4 600/450 985.9/842.6 600/450
288.0/209.5 300/250 541.3/462.9 300/225
241.6/176.8 250/200 449.6/384.8 250/200
195.9/144.1 225/175 363.5/311.7 225/175
519.8/306.2 600/400 962.0/748.4 600/350
274.9/160.2 300/200 528.3/413.6 300/175
230.8/135.2 250/175 438.8/343.2 250/150
187.3/110.2 200/125 354.9/277.8 200/125
543.7/400.4 600/450 985.9/842.6 600/450
288.0/209.5 300/250 541.3/462.9 300/225
241.6/176.8 250/200 449.6/384.8 250/200
195.9/144.1 225/175 363.5/311.7 225/175
543.7/400.4 600/450 985.9/842.6 600/450
288.0/209.5 300/250 541.3/462.9 300/225
241.6/176.8 250/200 449.6/384.8 250/200
195.9/144.1 225/175 363.5/311.7 225/175
LEGEND
MOCP Maximum Overcurrent Protection
(Ckt1/Ckt2)
XL
Across-the-Line Start
NOTES:
1. Units are suitable for use on electrical systems where voltage supplied to the unit terminals
is not below or above the listed minimum and maximum limits. Maximum allowable phase
imbalance is: voltage, 2%; amps 10%.
2. Control power is derived from main power. No separate control power connection is
required.
3. Cooler heater is wired into the control circuit so it is always operable as long as the power
supply disconnect is on, even if any safety device is open.
4. For MCA that is less than or equal to 380 amps, 3 conductors are required.
For MCA between 381 and 760 amps, 6 conductors are required.
For MCA between 761 and 1140 amps, 9 conductors are required.
For MCA between 1141 and 1520 amps, 12 conductors are required.
Calculation of conductors required is based on 75 C copper wire.
MCA
XL
Rec Fuse
Size
MCA
XL
Rec Fuse
Size
5. Wiring for main field supply must be rated 75 C minimum. Use copper for all units.
a. Incoming wire size range for the terminal block is no. 4 AWG (American Wire Gage) to
500 kcmil.
b. Incoming wire size range of non-fused disconnect with MCA up to 599.9 amps is 3/0 to
500 kcmil.
c. Incoming wire size range of non-fused disconnect with MCA from 600 to 799.9 amps is
1/0 to 500 kcmil.
d. Incoming wire size range of non-fused disconnect with MCA from 800 to 1199.9 amps is
250 kcmil to 500 kcmil.
6. Hydronic pump packages are not available as a factory-installed option for units
30RB210-390.
7. Power draw includes both crankcase heaters and cooler heaters (where used). Each compressor has a crankcase heater which draws 56 watts of power. Units ordered with the
cooler heater option have 1 (060-150) or 2 (160-300) cooler heaters, 825 watts each.
208/230
460
575 v only
68
070
080
090
100
110
120
130
150
160
170
190
ICF
UNIT VOLTAGE
Supplied
Min Max
208/230-60 187 253
380-60
342 418
460-60
414 506
575-60
518 633
208/230-60 187 253
380-60
342 418
460-60
414 506
575-60
518 633
208/230-60 187 253
380-60
342 418
460-60
414 506
575-60
518 633
208/230-60 187 253
380-60
342 418
460-60
414 506
575-60
518 633
208/230-60 187 253
380-60
342 418
460-60
414 506
575-60
518 633
208/230-60 187 253
380-60
342 418
460-60
414 506
575-60
518 633
208/230-60 187 253
380-60
342 418
460-60
414 506
575-60
518 633
208/230-60 187 253
380-60
342 418
460-60
414 506
575-60
518 633
208/230-60 187 253
380-60
342 418
460-60
414 506
575-60
518 633
208/230-60 187 253
380-60
342 418
460-60
414 506
575-60
518 633
208/230-60 187 253
380-60
342 418
460-60
414 506
575-60
518 633
208/230-60 187 253
380-60
342 418
460-60
414 506
575-60
518 633
V-Hz (3 Ph)
MCA
XL
193.8/141.5
100.4/ 74.1
85.1/ 62.5
68.2/ 50.0
237.0/141.5
124.9/ 74.1
105.1/ 62.5
85.5/ 50.0
241.5/168.8
126.5/ 86.4
106.7/ 73.6
85.4/ 59.0
308.6/168.8
164.1/ 86.4
137.5/ 73.6
111.4/ 59.0
308.6/212.0
164.1/110.9
137.5/ 93.6
111.4/ 76.3
308.6/243.8
164.1/124.8
137.5/106.3
111.4/ 85.2
320.5/306.2
170.7/160.2
142.9/135.2
115.7/110.2
426.7/243.8
226.5/124.8
189.9/106.3
153.9/ 85.2
426.7/306.2
226.5/160.2
189.9/135.2
153.9/110.2
544.8/243.8
288.9/124.8
242.3/106.3
196.5/ 85.2
544.8/306.2
288.9/160.2
242.3/135.2
196.5/110.2
568.7/400.4
302.0/209.5
253.1/176.8
205.1/144.1
LEGEND
MOCP Maximum Overcurrent Protection
(Ckt1/Ckt2)
XL
Across-the-Line Start
NOTES:
1. Units are suitable for use on electrical systems where voltage supplied to the unit terminals
is not below or above the listed minimum and maximum limits. Maximum allowable phase
imbalance is: voltage, 2%; amps 10%.
2. Control power is derived from main power. No separate control power connection is
required.
3. Cooler heater is wired into the control circuit so it is always operable as long as the power
supply disconnect is on, even if any safety device is open.
4. For MCA that is less than or equal to 380 amps, 3 conductors are required.
For MCA between 381 and 760 amps, 6 conductors are required.
For MCA between 761 and 1140 amps, 9 conductors are required.
For MCA between 1141 and 1520 amps, 12 conductors are required.
Calculation of conductors required is based on 75 C copper wire.
Rec Fuse
Size
225/175
110/ 90
100/ 80
80/ 60
300/175
150/ 90
125/ 80
100/ 60
300/200
150/100
125/ 90
100/ 70
350/200
200/100
150/ 90
125/ 70
350/250
200/125
150/110
125/ 90
350/300
200/150
150/125
125/100
350/350
200/175
175/150
125/125
500/300
250/150
225/125
175/100
500/350
250/175
225/150
175/125
600/300
300/150
250/125
225/100
600/350
300/175
250/150
225/125
600/450
350/225
300/200
225/175
MCA
XL
253.2/168.8
133.5/ 86.4
112.2/ 73.6
90.2/ 59.0
320.3/168.8
171.1/ 86.4
143.0/ 73.6
116.2/ 59.0
320.3/212.0
171.1/110.9
143.0/ 93.6
116.2/ 76.3
320.3/243.8
171.1/124.8
143.0/106.3
116.2/ 85.2
332.2/306.2
177.7/160.2
148.4/135.2
120.5/110.2
438.4/243.8
233.5/124.8
195.4/106.3
158.7/ 85.2
438.4/306.2
233.5/160.2
195.4/135.2
158.7/110.2
556.5/243.8
295.9/124.8
247.8/106.3
201.3/ 85.2
556.5/306.2
295.9/160.2
247.8/135.2
201.3/110.2
580.4/400.4
309.0/209.5
258.6/176.8
209.9/144.1
300/225
657.5/560.0
150/110
351.8/298.4
125/100
291.8/247.7
110/ 80
236.5/201.2
400/225
775.6/560.0
200/110
430.8/298.4
175/100
356.5/247.7
150/ 80
287.8/201.2
400/300
775.6/654.2
200/150
430.8/364.3
175/125
356.5/301.6
150/110
287.8/243.9
400/300
775.6/635.0
200/150
430.8/336.8
175/125
356.5/280.4
150/110
287.8/227.4
400/400
787.6/748.4
225/200
437.3/413.6
175/175
361.9/343.2
150/125
292.1/277.8
500/300
893.7/635.0
250/150
493.1/336.8
225/125
408.9/280.4
175/110
330.4/227.4
500/400
893.7/748.4
250/200
493.1/413.6
225/175
408.9/343.2
175/125
330.4/277.8
600/300 1011.8/635.0
300/150
555.5/336.8
250/125
461.3/280.4
225/110
372.9/227.4
600/400 1011.8/748.4
350/200
555.5/413.6
250/175
461.3/343.2
225/125
372.9/277.8
600/450 1035.7/842.6
350/250
568.6/462.9
300/200
472.1/384.8
225/175
381.5/311.7
Rec Fuse
Size
300/200
150/100
125/ 90
100/ 70
350/200
200/100
175/ 90
125/ 70
350/250
200/125
175/110
125/ 90
350/300
200/150
175/125
125/100
400/350
200/175
175/150
150/125
500/300
250/150
225/125
175/100
500/350
250/175
225/150
175/125
600/300
350/150
300/125
225/100
600/350
350/175
300/150
225/125
600/450
350/225
300/200
225/175
5. Wiring for main field supply must be rated 75 C minimum. Use copper for all units.
a. Incoming wire size range for the terminal block is no. 4 AWG (American Wire Gage) to
500 kcmil.
b. Incoming wire size range of non-fused disconnect with MCA up to 599.9 amps is 3/0 to
500 kcmil.
c. Incoming wire size range of non-fused disconnect with MCA from 600 to 799.9 amps is
1/0 to 500 kcmil.
d. Incoming wire size range of non-fused disconnect with MCA from 800 to 1199.9 amps is
250 kcmil to 500 kcmil.
6. Hydronic pump packages are not available as a factory-installed option for units
30RB210-390.
7. Power draw includes both crankcase heaters and cooler heaters (where used). Each compressor has a crankcase heater which draws 56 watts of power. Units ordered with the
cooler heater option have 1 (060-150) or 2 (160-300) cooler heaters, 825 watts each.
208/230
460
575 v only
69
VOLTAGE
ELECTRICAL OPTION
060,070
208/230, 380,
460, 575
208/230
080-120
380, 460, 575
208/230
CONNECTIONS
Single Point
Dual Point
Single Point
Single Point
Dual Point
Single Point
Single Point
Dual Point
Single Point
Single Point
Dual Point
Single Point
Dual Point
Single Point
Dual Point
Single Point
Dual Point
Dual Point
208/230
Non-Fused Disconnect Option
Dual Point
Single Point
210, 225
Dual Point
Single Point
Dual Point
Dual Point
208/230
Non-Fused Disconnect Option
250-300
LEGEND
Power Electrical Box
*Dual point connection is not available when non-fused disconnect option is selected.
Single point connection not available.
70
Dual Point
Single Point
Non-Fused Disconnect
PEB
Dual Point
Single Point
Dual Point
CONTROL BOX
Combination
Combination
Combination
Combination
Power-L
Power-L
Power-L
Power-L
Combination
Combination
Combination
Combination
Power-L
Power-L
PEB1
Power-L
Power-L
PEB1
PEB1
PEB1
PEB1
PEB1
PEB1
Power-L
Power-L
PEB2
Power-L
PEB2
PEB1
PEB1
PEB1
PEB1
PEB1
Power-L
Power-L
PEB2
Power-L
PEB2
PEB1
PEB1
PEB2
PEB1
PEB1
PEB2
080
120
130, 150
160,170,
315A, 315B, 330A,
330B, 345A, 345B,
360B
190, 360A, 390A,
390B
210, 225
250
275
300
UNIT VOLTAGE
V-Hz (3 Ph)
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
Circuit A Quantity
3
3
3
3
2
2
2
2
3
3
3
3
3
3
3
3
4
4
4
4
6
6
6
6
6
6
6
6
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
FLA (each)
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
Circuit C Quantity
4
4
4
4
6
6
6
6
4
4
4
4
6
6
6
6
FLA (each)
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
11.9
6.5
5.4
4.3
LEGEND
FLA Full Load Amps
7.5
10
15
UNIT VOLTAGE
V-Hz (3 Ph)
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
060, 070
060-190
060-190
060-190
080-190
LEGEND
FLA Full Load Amps
*Hydronic pump packages are not available as a factory-installed option for units 30RB210-390.
71
060
070
080
090
100
110
120
130
150
210
225
250
275
300
LEGEND
LRA Locked Rotor Amps
RLA Rated Load Amps
72
UNIT VOLTAGE
V-Hz (3 Ph)
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
208/230-60
380-60
460-60
575-60
A1
RLA LRA
75.0 485
38.4 260
32.7 215
26.2 175
94.2 560
49.3 315
41.6 260
33.9 210
75.0 485
38.4 260
32.7 215
26.2 175
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
COMPRESSOR
A2
A3
RLA LRA RLA LRA
75.0 485
38.4 260
32.7 215
26.2 175
94.2 560
49.3 315
41.6 260
33.9 210
75.0 485
38.4 260
32.7 215
26.2 175
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
A4
RLA LRA
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
B1
RLA LRA
75.0 485
38.4 260
32.7 215
26.2 175
75.0 485
38.4 260
32.7 215
26.2 175
75.0 485
38.4 260
32.7 215
26.2 175
75.0 485
38.4 260
32.7 215
26.2 175
94.2 560
49.3 315
41.6 260
33.9 210
75.0 485
38.4 260
32.7 215
26.2 175
94.2 560
49.3 315
41.6 260
33.9 210
75.0 485
38.4 260
32.7 215
26.2 175
94.2 560
49.3 315
41.6 260
33.9 210
75.0 485
38.4 260
32.7 215
26.2 175
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
75.0 485
38.4 260
32.7 215
26.2 175
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
COMPRESSOR
B2
B3
RLA LRA RLA LRA
75.0 485
38.4 260
32.7 215
26.2 175
75.0 485
38.4 260
32.7 215
26.2 175
94.2 560
49.3 315
41.6 260
33.9 210
B4
RLA LRA
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
C1
RLA LRA
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
COMPRESSOR
C2
C3
RLA LRA RLA LRA
C4
RLA LRA
94.2 560
49.3 315
41.6 260
33.9 210
94.2 560
49.3 315
41.6 260
33.9 210
Controls
Microprocessor
The ComfortLink microprocessor controls overall unit operation. Its central executive routine controls a number of processes simultaneously. These include internal timers, reading
inputs, analog to digital conversions, fan control, display
control, diagnostic control, output relay control, demand
limit, capacity control, head pressure control, and temperature reset. Some processes are updated almost continuously,
others every 2 to 3 seconds, and some every 30 seconds.
The microprocessor routine is started by switching the
Emergency ON-OFF switch to ON position. Pump control
of external pumps (where so configured) or optional internal
pump, will energize the cooler pump to the internal (or
CCN) time schedule (or input occupied signal from external
system).
Where dual pumps are utilized only one pump will be
operated at a time. The control will start the pump with the
least hours. When the unit receives a call for cooling (based
on a deviation from chilled water set point), the unit stages
up in capacity to maintain the cooler fluid set point. The
first compressor starts 1 to 3 minutes after the call for cooling. The ComfortLink microprocessor controls the capacity of the chiller by cycling compressors at a rate to satisfy
actual dynamic load conditions. The control maintains
leaving-fluid temperature set point shown on the scrolling
marquee display board through intelligent cycling. Accuracy depends on loop volume, loop flow rate, load,
outdoor-air temperature, number of stages, and particular
stage being cycled off. No adjustment for cooling range or
cooler flow rate is required, because the control automatically compensates for cooling range by measuring both
return-fluid temperature and leaving-fluid temperature.
This is referred to as leaving-fluid temperature control with
return-fluid temperature compensation.
The basic logic for determining when to add or remove a
stage is a time band integration of deviation from set point
plus rate of change of leaving-fluid temperature. When
leaving-fluid temperature is close to set point and slowly
moving closer, logic prevents addition of another stage.
If 1 F per minute (0.6 C per minute) pulldown control has
been selected (adjustable setting), no additional steps of
capacity are added as long as the difference between leavingfluid temperature and set point is greater than 4 F (2.2 C)
and rate of change in leaving-fluid temperature is greater than
the selected pulldown control rate. If it has been less than
90 seconds since the last capacity change, compressors will
continue to run unless a safety device trips. This prevents
rapid cycling and also helps return oil during short on periods.
Sensors
Thermistors are used to control temperature-sensing inputs to
microprocessor. Additional thermistor sensors may be used as
remote temperature sensors for optional LCWT (leaving
chilled fluid temperature) reset.
Cooler leaving chilled fluid temperature (T1)
Cooler entering fluid (return) temperature (T2)
Outside-air temperature (T9)
Two refrigerant pressure transducers are used in each
circuit for sensing suction and discharge pressure. The
Control sequence
Off cycle If ambient temperature is below 36 F (2 C),
cooler heaters (if equipped) are also energized.
Start-up After the control circuit switches on, the prestart process takes place, then microprocessor checks
itself, starts pump (if configured) and waits for temperature
to stabilize. The controlled pulldown feature limits compressor loading on start-up to reduce demand on start-up
and unnecessary compressor usage. The microprocessor
limits supply-fluid temperature decrease (start-up only) to
1 F (0.6 C) per minute.
Capacity control On first call for cooling, microprocessor starts initial compressor and fan stage on lead
circuit.
As additional cooling is required, additional compressors
are energized.
Speed at which capacity is added or reduced is controlled by temperature deviation from set point and rate of
temperature change of chilled fluid.
The Main Base Board (MBB) responds to the supply
chilled water temperature to cycle the compressors to
match cooling load requirements.
Minimum load control valve is energized by the MBB.
Valve allows hot gas to pass directly into the cooler circuit
on the final step of unloading, permitting the unit to operate at lower loads with less compressor cycling.
Additional information
Detailed information on controls and operation is available
in the Controls, Start-Up, Operation and Troubleshooting
guide included with each unit. Packaged Service Training
programs are also available. Contact your Carrier representative for more information.
Dual chiller control The ComfortLink controller
allows 2 chillers (piped in parallel) to operate as a single
chilled water plant with standard control functions coordinated through the master chiller controller. This standard
ComfortLink feature requires a communication link
between the 2 chillers and, in the case of parallel chillers,
requires an additional thermistor and well for each chiller.
Dynamic ComfortLink controls Dynamic ComfortLinkcontrols keep the chiller on line during periods of
extreme operating conditions. If the entering fluid temperature is 85 F (29 C) or higher and the saturated suction
temperature is 50 F (10 C) or higher the maximum operating pressure (MOP) feature limits the suction to keep the
chiller online. The control automatically starts the chiller in
the unloaded state to eliminate the potential of compressor
overload due to high head pressure or low suction pressure. The controller will equalize run time on each circuit
through the lead/lag feature. If a circuit becomes disabled,
the control will automatically set the active circuit to lead,
keeping the chiller online at a reduced capacity.
73
Controls (cont)
CAPACITY CONTROL STEPS*
UNIT 30RB
060
070
080
090
100
110
120
130
150
160
170
190
210
225
250
275
300
315
330
345
360
390
74
Temperature reset
The energy management module (EMM) is required for 4
to 20 mA reset of LCWT in constant fluid systems. Reset
by return fluid, outdoor-air temperature, or space temperature does not require this option. Reset reduces compressor power usage at part load when design LCWT is not
necessary. Humidity control should be considered since
higher coil temperatures resulting from reset will reduce
latent heat capacity. Three reset options are offered, based
on the following:
Return-fluid temperature Increases LCWT set point
as return (or entering) fluid temperature decreases (indicating load decrease). Option may be used in any application
where return fluid provides accurate load indication. Limitation of return fluid reset is that LCWT may only be reset
to value of design return fluid temperature.
Outdoor-air temperature Increases LCWT as outdoor ambient temperature decreases (indicating load
decrease). This reset should be applied only where outdoor
ambient temperature is an accurate indication of load. An
accessory thermistor is required.
Space temperature Increases LCWT as space temperature decreases (indicating load decrease). This reset
should be applied only where space temperature is an
accurate indication of load. An accessory thermistor and
the energy management module accessory is required.
For details on applying a reset option, refer to unit
Controls and Troubleshooting literature. Obtain ordering
part numbers for reset option from the Packaged
Chiller Builder program or contact your local Carrier
representative.
Accessory controls
Demand can be limited by controlling the chiller capacity
through the demand limit control (the energy management
module is required for this function). This factory-installed
option or accessory interfaces with microprocessor to control unit so that chillers kW demand does not exceed its
setting. It is activated from an external switch or a 4 to
20 mA signal.
The standard ComfortLink controller is programmed to
accept various accessory temperature reset options (based
on outdoor-air temperature [std], return-fluid temperature,
or space temperature), that reset the LCWT. An accessory
thermistor (T10) is required if outdoor-air temperature or
space temperature reset is selected. The energy
management module (EMM) is only required for temperature reset that is initiated by a 4 to 20 mA signal.
Demand limit
If applied, limits the total power draw of unit to selected
point by controlling number of operational compressors
during periods of peak electrical demand.
The energy management module is required for either 2step or 4 to 20 mA demand limit.
microprocessor input. The orifice is positioned by a stepper motor through approximately 3,600 discrete steps and
is monitored every three seconds. The EXV maintains an
approximate 8 F (5 C) refrigerant superheat entering the
compressor.
Diagnostics
The microprocessor may be put through a service test (see
Controls, Start-Up, Operation, Service, and Troubleshooting literature). Service test confirms microprocessor is
functional, informs observer through display the condition
of each sensor and switch in chiller, and allows observer to
check for proper operation of fans and compressors.
Default settings
To facilitate quick start-ups, 30RB chillers with
ComfortLink controls are pre-configured with a default
setting that assumes stand-alone operation supplying 44 F
(6.7 C) chilled water.
Configuration settings will be based on any options
or accessories included with the unit at the time of
manufacturing.
Date and time are set to U.S.A. Eastern Time zone and
will need reconfiguring based on location and local time
zone. If operation based on occupancy scheduling is
desired, this will also need to be set during installation.
Ice duty
ComfortLink controls have the capability of reduced leaving fluid temperature operation for thermal storage, or ice
duty. The optional Energy Management display includes
input contacts for the ice done signal generated by the
thermal storage control system. The ice duty feature may
be configured to start on an external input command or by
the ComfortLink standard internal scheduling function.
The ice duty function requires brine modification for leaving fluid temperatures below 30 F (1.1 C) for chiller sizes
30RB110-390. No modification is required for the ice duty
function with chiller sizes 30RB060-100. Ice duty may be
used in combination with any other standard features
offered by the energy management module and ComfortLink controls.
The production of ice, which is stored for peak cooling
demands, can significantly decrease energy costs. The unit
produces ice (normally at night) by supplying ice storage
tanks with low temperature cooling fluid. The chiller takes
advantage of reduced ambient conditions at night for icemaking mode, so the capacity suffers a lower penalty for
the low leaving fluid temperatures.
At peak cooling demands the chiller and the stored ice
may share the cooling load to reduce operating costs. The
thermal storage system may potentially reduce the size of
the chiller plant required to meet demand loads.
75
J7A
ALARM
CHILLED WATER PUMP INTERLOCK
CHILLED WATER PUMP
ENERGY MANAGEMENT
SHUTDOWN RELAY
RUN RELAY
MINIMUM LOAD VALVE
TERMINAL BLOCK
FIELD POWER WIRING
FIELD CONTROL WIRING
FACTORY INSTALLED WIRING
160
170
190
330A
345A,B
360B
360A
390A,B
FEB
GRN-YEL
SILVER SCREW
COMBI
OR
POWER-L
X3
X1
LOAD
TEST
RESET
LINE
PEB 1
XF
TB6
5V
CH
5
CH
6
2
4
PEB2
CH
10
CH
2
J6
8
CH
11A
TB5
CH
8
CH
9
12 13 14 15
DUAL SETPOINT
PMPI
10
9
11
EMM BOARD
(4 AMPS MAX.)
OUTLET
CIRCUIT-INTERRUPTER
GROUND-FAULT
J4
BRASS SCREW
BLK
FU4
GFI-CO
FIOP/ACCESSORY
WHT
DISPLAY LOCATION
FIELD CONTROL
WIRING ENTRY
060,070 230V
060-120 380/460/575V
FIELD CONTROL
WIRING ENTRY
080-300 230V
130-300 380/460/575V
DISPLAY LOCATION
STD UNIT
SIZE
315A,B
330B
DUPLEX UNITS
A
PMPICWP EMM SHD RRUN RMLV TB -
SECONDARY
115V
S
TRAN2
R
GRN
J7B
S
GRN
LEGEND:
5V
BLK
1/2 WATT 250
VIO
REMOTE LOCKOUT SWITCH
+
6
BLU
R
4
J4
5
BLU
J4
6
RED
J4
3
ORN
VIO
4-20 MA
SIGNAL
GENERATOR
CH
25
J3
CH
24
+
4
GRA
GRA
SPACE
TEMP
(10K)
ICE DONE
BLK
SETPOINT
RESET
4-20 MA
SIGNAL
GENERATOR
CAPACITY
LIMIT
RED
OCCUPANCY OVERRIDE
ORN
8
T8
3
SHD
R
B
MLV-A
REMOTE
ON/OFF
SEE
NOTE 3
10
11
Net-
12 13 14 15
Net+
SHIELD
PMP1
PMP2
Network
Wiring
BAS Port
Network COM
EMM
FIOP/
ACCESSORY
SHLD - COM
RUN
R
MLV-C
A
SW2 C
ON/OFF
TB5
13
MLV-B
UPC
Open
EQUIP
GND
SUPPLY
EQUIP
GND
NON-FUSED DISCONNECT
POWER
DISCONNECT/BRANCH CIRCUIT
FIELD
TERMINAL BLOCK
SUPPLY
13
23
DISCONNECT/BRANCH CIRCUIT
POWER
12
11
FIELD
22
21
GROUND
76
GROUND
NOTES:
a30-5188
()
(+)
LEGEND
Field Control Wiring
Factory Installed Wiring
NOTES:
1. Terminals 1 and 2 of TB7 are for external connection of heat
reclaim condenser water valve.
2. Terminals 3 and 4 of TB7 are for external connection of fieldsupplied heat reclaim water pump control relay.
3. The maximum load allowed for the condenser pump relay is
5 va sealed, 10 va inrush at 24 v.
4. Terminals 14 and 15 of TB7 are for external connection of
heat reclaim remote enable switch.
5. Terminals 5 through 13 of TB7 are for the connection of
factory-installed solenoid valve control wiring.
a30-4742
77
Application data
Chiller location and clearances
Do not locate near sound sensitive areas without proper
acoustic consideration. For applications requiring mounting a chiller on a building rooftop, consideration should be
given to using rubber-in-shear or spring isolators to minimize structure-borne transmission. Unit must be level when
installed to ensure proper oil return to the compressors.
Clearances must be provided around chillers for airflow,
service and local code requirements. See dimensional
drawings for specific unit clearance requirements. Ensure
adequate clearance between adjacent chillers is maintained. A minimum of 10 ft (3048 mm) is recommended.
Chiller fan discharge must be at least as high as adjacent
solid walls. Installation in pits is not recommended.
Minimum clearances
The recommended minimum clearance to ensure proper
airflow through the condenser coils and to allow fan maintenance is as shown below.
Acceptable clearance on the cooler connection side or
end opposite the control box of the unit can be reduced to
3 ft (1 m) without sacrificing performance as long as the
remaining three sides are unrestricted. Acceptable clearance on the side with a control box can be reduced to 4 ft
(1.3 m) due to NEC (National Electric Code) regulations,
without sacrificing performance as long as the remaining
three sides are unrestricted. Clearances between chillers in
dual chiller applications may be reduced to 6 ft (1.8m) without sacrificing performance provided the remaining sides
are unrestricted. For acceptable clearance with layout
involving more than 2 chillers, please contact application
engineering.
MULTIPLE UNIT SEPARATION
a30-4904
6 ft (1.8 m)
MINIMUM
10 ft
(3 m)*
MINIMUM
* 12 ft (3.7m) required for unit sizes 275 and 300. For applications
with higher than 115 F ambient, contact application engineering.
Oversizing chillers
Oversizing chillers by more than 15% at design conditions
must be avoided as the system operating efficiency is
adversely affected (resulting in greater or excessive electrical demand). When future expansion of equipment is
anticipated, install a single chiller to meet present load
requirements and add a second chiller to meet the additional load demand. It is also recommended that 2 smaller
chillers be installed where operation at minimum load is
critical. The operation of a smaller chiller loaded to a
greater percentage over minimum is preferred to operating
a single chiller at or near its minimum recommended value.
Minimum load control should not be used as a means to
allow oversizing chillers. Minimum load control should be
given consideration where substantial operating time is
anticipated below the minimum unloading step.
78
Multiple chillers
Where chiller capacities greater than can be supplied by a
single 30RB chiller are required, or where stand-by capability is desired, chillers may be installed in parallel. Units
may be of the same or different sizes with this piping arrangement. However, cooler flow rates must be balanced
to ensure proper flow to each chiller.
Unit software is capable of controlling two parallel units
as a single plant by making use of the dual chiller control
feature. Refer to the Controls, Start-up, Operation, Service
and Troubleshooting guide for further details. The accessory Chillervisor System Manager can be used to ensure
proper staging sequence of up to 8 chillers. Refer to the
accessory Chillervisor System Manager installation instructions for further details.
If the dual chiller algorithm is used, and the machines are
installed in parallel, an additional chilled water sensor must
be installed for each module. For 30RB315-390, where it
is understood that these are duplex chillers comprised of 2
chillers to be installed in parallel, two factory-supplied
thermistors and wells are shipped in the control box of one
of the modules (for other 30RB chiller sizes which will be
installed in a parallel piping configuration, a dual chiller accessory kit is available). Install one thermistor and well per
chiller in the common leaving water header.
Parallel chiller control with dedicated pumps is recommended. The chiller must start and stop its own water
pump located in its own piping. Check valves are required
at the discharge of each pump (when the factory hydronic
package option is chosen, and dual pumps are selected, the check valves are automatically supplied). If
pumps are not dedicated for each chiller, then isolation
valves are required. Each chiller must open and close its
own isolation valve through the unit control (the valve must
be connected to the pump outputs). Refer to the chiller
piping configuration shown on the next page.
If a series application is required, the master/slave control feature cannot be used. Hydronic pump packages may
not be applied in series applications.
Series chillers
Where a large temperature drop (greater than 20 F
[11.1 C]) is desired or where chiller capacities greater than
can be supplied by a single 30RB chiller are required or
where standby capability is required, chillers may be
installed in series. The leaving fluid temperature sensors
need not be relocated. However, the cooler minimum
entering fluid temperature limitations should be considered
for the chillers located downstream of other chillers. Use of
reduced pass heads may be required to keep waterside
pressure drop at an acceptable level. When chillers are
operated in a series arrangement, the use of a Chillervisor
System Manager is recommended.
OR ISOLATION VALVE
CONTROL
BOX
SLAVE CHILLER
LWT
LEGEND
Leaving Water Temperature
Field-Installed Communication Bus
Field-Installed Wiring
OR ISOLATION VALVE
a30-4453
DUAL CHILLER
LWT SENSORS
& WELLS
Minimum cooler flow (maximum cooler temperature rise) The minimum cooler flow for standard units
is shown in Minimum and Maximum Cooler Fluid Flow
Rates table. When system design conditions require a
lower flow (or higher rise) than the minimum allowable
cooler flow, follow the recommendations below.
a. Multiple smaller chillers may be applied in series, each
providing a portion of the design temperature rise.
b. Cooler fluid may be recirculated to raise the flow rate to
the chiller. The mixed temperature entering the cooler
must be maintained to a minimum of at least 5 F
(2.8 C) above the LCWT and to a maximum of no
more than 20 F (11.1 C) above the LCWT.
NOTE: Recirculation flow is shown below.
RECIRCULATION FLOW
Strainers
It is recommended that a strainer with a minimum of 20
mesh be installed in the cooler fluid inlet line, just ahead of
(and as close as possible) to the cooler.
Cooler flow/range
Ratings and performance data in this publication are for a
cooling temperature rise of 10 F (6 C). The 30RB chillers
may be operated at a different temperature rise, providing
flow limits are not exceeded and corrections to system
guidelines are made. For minimum and maximum cooler
flow rates, see the Minimum and Maximum Cooler Flow
Rates table. A high flow rate is generally limited by the
maximum pressure drop that can be tolerated by the unit.
The 30RB chillers are designed for a full load temperature
rise of 5 to 20 F (2.8 to 11. 1 C). Use the Packaged
Chiller Builder Program to obtain the rating if a temperature rise other than 10 F (6 C) is used.
a30-4042
79
a30-533
MINIMUM COOLER
FLOW RATE (gpm)*
72
84
96
108
120
132
144
156
180
192
204
228
252
270
300
330
360
MAXIMUM COOLER
FLOW RATE (gpm)
288
336
384
432
480
528
576
624
720
768
816
912
950
950
950
950
950
MINIMUM LOOP
VOLUME (gal.)
180
210
240
270
300
330
360
390
450
480
510
570
630
675
750
825
900
MINIMUM COOLER
FLOW RATE (l/s)*
5
5
6
7
8
8
9
10
11
12
13
14
16
17
19
21
23
MAXIMUM COOLER
FLOW RATE (l/s)
18
21
24
27
30
33
36
39
45
48
51
58
60
60
60
60
60
MINIMUM LOOP
VOLUME (liters)
681
795
908
1022
1136
1249
1363
1476
1703
1817
1931
2158
2385
2555
2839
3123
3407
SIZES 315-390
30RB
SIZE
315
330
345
360
390
MINIMUM COOLER
FLOW RATE (gpm)*
Module A
Module B
192
192
204
192
204
204
228
204
228
228
MAXIMUM COOLER
FLOW RATE (gpm)
Module A
Module B
768
768
816
768
816
816
912
816
912
912
MINIMUM LOOP
VOLUME (gal.)
945
990
1035
1080
1170
MINIMUM COOLER
FLOW RATE (l/s)*
Module A
Module B
12
12
13
12
13
13
14
13
14
14
MAXIMUM COOLER
FLOW RATE (l/s)
Module A
Module B
48
48
51
48
51
51
58
51
58
58
MINIMUM LOOP
VOLUME (liters)
3577
3748
3918
4088
4429
* For minimum cooler flow rate with brine applications, refer to E-cat
software performance.
The piping between the chiller and the fluid loop volume
tank can be done to allow the tank to be on the return side
of the chiller (tank piped to chiller inlet) or the supply side
of the chiller (tank piped to the chiller outlet). However, it is
recommended that the tank be piped to the return side of
the chiller to buffer any changes in load to allow more stable chiller operation.
BAD
BAD
a30-3185
GOOD
81
FOULING FACTORS
FOULING FACTOR
(English)
(ft2hrF/Btu)
0.00025
0.00050
0.00075
0.00175
FOULING
FACTOR
(SI)
(m2C/W)
0.000044
0.000088
0.000132
0.000308
CAPACITY
MULTIPLIER
COMPRESSOR
POWER
MULTIPLIER
0.991
0.977
0.955
0.910
0.995
0.987
0.979
0.952
82
High outdoor ambient chiller start-up and operation is possible for standard 30RB chillers at ambient temperatures
up to 125 F (52 C) at nominal voltage. In some cases,
where return water temperature is expected to exceed
60 F (15.5 C), an accessory kit may be required.
ALTITUDE
(m)
CAPACITY
MULTIPLIER
2,000
4,000
6,000
8,000
10,000
610
1220
1830
2440
3050
0.99
0.98
0.97
0.96
0.95
COMPRESSOR
POWER
MULTIPLIER
1.01
1.02
1.03
1.04
1.05
Condenser airflow
Airflow restrictions on units with standard fans will affect
the unit capacity, condenser head pressure, and compressor power input. Correction factors to be applied for external static restrictions up to 0.2 in. wg (50 Pa) are as
follows:
EXTERNAL STATIC
in. wg
Pa
0.0
0.0
0.1
25
0.2
50
CAPACITY
MULTIPLIER
COMPRESSOR
POWER MULTIPLIER
1.000
0.986
0.968
1.00
1.01
1.03
Electrical/utility interests
Use of energy management practices can significantly
reduce operating costs, especially during off-peak modes
of operation. Demand limiting and temperature reset are 2
techniques for accomplishing efficient energy management. See Demand Limiting (also called load shedding) section below for further details.
also be driven by an external 4 to 20 mA signal. These features require a signal from an intelligent central control. Do
not cycle demand limiter for less than 10 minutes on and
5 minutes off. Duty cycling cycles electrical loads at regular
intervals regardless of need. This reduces the electrical
operating costs of building by fooling demand indicating
devices. Duty cycling of compressors or fans is not recommended since motor winding and bearing life will suffer
from constant cycling.
Air separation
The AquaSnap 30RB chiller will require a field-supplied air
separation device when the optional pumping package is
provided.
Air must be controlled in a hydronic system if it is to perform properly. Air can block the flow of chilled water to its
destinations and can cause cavitation in the pump, which
will aerate the pump and potentially cause pump failure.
The air separator is sized according to the total flow
through the system. The air separator should be located
inside the building. There are several types of air separators to choose from. For more information and product
selection contact your local manufacturers representative.
83
ZONE 3
EXPANSION
TANK(S)
ZONE 2
DISTRIBUTION
PUMP
ZONE 1
CHILLER 2
CHILLER 1
AIR ELIMINATOR
WITH VENT
COLD WATER
MAKEUP/FILL SYSTEM
Heat reclaim
Whenever a chiller is operating, the heat removed from the
cooler fluid as well as the energy associated with the compression process must be moved to another location.
Under standard operation, an air-cooled chiller moves and
releases this heat to the atmosphere. There are times,
however, when it is beneficial to capture this heat and convert it into useful hot water.
The heat reclaim option has been developed to serve this
purpose. Unlike many heat reclaim schemes seen on the
market, the heat reclaim option that has been developed
for the 30RB is full condensing. This means that this
water-cooled condenser, which is in parallel with the
standard air-cooled condenser, is capable of capturing all of
the heat available from the chiller condensing process. The
leaving water temperature can reach at maximum 131 F
(55 C) under steady state and constant hot water flow conditions with an allowable hot water temperature range
from 68 to 131 F (20 to 55 C).
To operate in the heat reclaim mode, there must be a
simultaneous need for chilled water and tempered hot
water. Just as the chiller operates in standard duty, the
chiller always controls the leaving chilled water temperature. Consequently, the chiller will produce as much hot
water as possible while maintaining the leaving chilled
water temperature.
To generate hot water, the entering hot water temperature is compared to the hot water set point to determine
the number of circuits necessary to maintain the entering
hot water temperature. If the entering hot water temperature is below the customer-adjustable set point, one refrigeration circuit will automatically be changed over to the
heat recovery mode to produce tempered hot water. In this
mode, the chiller is operating as a water-cooled chiller with
one circuit and as an air-cooled chiller with the other
circuit.
Depending on the entering hot water requirements, the
second circuit may also be switched to the heat recovery
mode through the integrated controls. The entering hot
water temperature is controlled by the cycling of each
refrigerant circuit from the cooling-only to the heat recovery modes. When the hot water set point is satisfied, the
chiller will transition back to the cooling-only mode as a
84
a30-3652
EWT
LWT
OAT
F
C
F
C
Min
-20*
-29*
38 (LWT)
3 (LWT)
CONDITIONS
Nominal
Max
95
125
35
52
54/44
60 (LWT)
12/7
16 (LWT)
LEGEND
Entering Water (Fluid) Temperature
Leaving Water (Fluid) Temperature
Outdoor Air Temperature
F
C
F
C
Min
68* (EWT)
20* (EWT)
38 (LWT)
3 (LWT)
CONDITIONS
Nominal
104/114
40/46
54/44
12/7
Max
131 (LWT)
55 (LWT)
59 (LWT)
15 (LWT)
LEGEND
Entering Water (Fluid) Temperature
Leaving Water (Fluid) Temperature
* Install three-way valve controls as required to ensure 68 F (20 C) minimum entering condenser temperature.
Condenser water flow must be maintained such that the maximum
heating condenser water temperature rise is no more than 20 F
(11 C) and the minimum heating condenser water temperature rise
is no less than 5 F (3 C).
85
Guide specifications
Outdoor Air-Cooled Liquid Chiller
HVAC Guide Specifications
Size Range:
60 to 390 Tons
(210 to 1370 kW) Nominal
Carrier Model Number: 30RB
Part 1 General
1.01 SYSTEM DESCRIPTION
Microprocessor controlled, air-cooled liquid chiller
utilizing scroll compressors, low sound fans and
optional hydronic pump system.
NOTE: Hydronic pump packages are only available
on 30RB060-190 units. Hydronic pump packages
are not available when optional heat reclaim is
selected.
1.02 QUALITY ASSURANCE
A. Unit shall be rated in accordance with AHRI Standard 550/590, latest edition (U.S.A.) and all units
shall be ASHRAE 90.1 compliant.
B. Unit construction shall comply with ASHRAE 15
Safety Code, UL latest edition, and ASME applicable codes (U.S.A. codes).
C. Unit shall be manufactured in a facility registered to
ISO 9001 Manufacturing Quality Standard.
D. Unit shall be full load run tested at the factory.
1.03 DELIVERY, STORAGE AND HANDLING
A. Unit controls shall be capable of withstanding
150 F (66 C) storage temperatures in the control
compartment.
B. Unit shall be stored and handled per unit manufacturer's recommendations.
Part 2 Products
2.01 EQUIPMENT
A. General:
Factory assembled, single-piece or factory-matched
duplex chassis, air-cooled liquid chiller. Contained
within the unit cabinet shall be all factory wiring,
piping, controls, refrigerant charge (R-410A), and
special features required prior to field start-up.
B. Unit Cabinet:
1. Frame shall be of heavy-gage, painted galvanized steel.
2. Cabinet shall be galvanized steel casing with a
baked enamel powder or pre-painted finish.
3. Cabinet shall be capable of withstanding
500-hour salt spray test in accordance with the
ASTM (U.S.A.) B-117 standard.
C. Fans:
1. Condenser fans shall be direct-driven, 9-blade
airfoil cross-section, reinforced polymer construction, shrouded-axial type, and shall be statically and dynamically balanced with inherent
corrosion resistance.
2. Air shall be discharged vertically upward.
86
D.
E.
F.
G.
H.
87
I.
J.
K.
L.
88
90
91
4-13
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Section 9
Pg 92
Catalog No. 04-52300060-01
Printed in U.S.A.
Form 30RB-17PD
Replaces: 30RB-16PD
Tab
9b