Вы находитесь на странице: 1из 4

Unlocking the Potential of Blood

T-ACE II+ AUTOMATIC COMPONENT EXTRACTOR


HIGh-END PROCESSING

STANDARDIZED HIGh-QUALITY BLOOD PROCESSING


T-ACE II+ AuTOMATIC COMpONENT EXTRACTOR
Major Benefits


Clear graphical color display for easy follow-up of each step of the separation process Automatic calibration of scales, detectors and press position Multiple detection system ensures correct tube and bag placement according to the selected protocol Safe press system protects operators from injuries during processing Ergonomic design telescopic bag support and rounded edges for comfortable handling Operation indicator optical signal for easy long distance status check Top angled press monitors and measures consequently with press position detection for high stability of layers during extraction and standardized small rest volume Electronic process control microprocessor monitors and measures consequently with a set of integrated scales and sensors the flow and the weight of all fluids

T-ACE II+ is a highly flexible automatic blood component extractor for the standardized processing of centrifuged blood according to Good Manufacturing Practice (GMP).
Versatility The device is designed to be used with all common bag systems of the top-and-bottom (TAB) and top-and-top (Conventional) type with or without inline filter(s). Processing protocols allow a wide range of separation procedures for the first and second separation (RBC, PRP, BC, PPP, PC). Superb flexibility is achieved with the use of 11 programs, programmable by external PC, stored on the devices motherboard. Each program is based on 4 protocols that can be optimally adapted to customers needs by different parameters and powerful subroutines. Special subroutines are available for procedures like air removal of filtered whole blood, aliquoting (Conventional procedure), diluted BC etc. Reliability and Safety

Your first choice for high quality and high recovery of blood components, cost effectiveness and secure compliance with your GMP requirements.

The correct positioning of tubes and bags, the opening of CLIKTIPS, and the flow of fluids are, based on the selected protocol, checked automatically. Clear operator instructions are given on the new graphical color display. The automated and microprocessor-monitored process is visualised schematically on the color display. Component, flow, component weights, clamp positions, sealing functions and flows are actively indicated by color changes. After finishing the process and in case of an error, the T-ACE II+ will give an audible signal and the operation indicator is activated. Terumos unique top angled pneumatic press is designed for a smooth start of the extraction process keeping layers stable. Pure components are guaranteed with a sharp detection of layers done by an intelligent interaction of the flow regulator and 11 optical sensors.

Technical Features

Operation indicator for long distance status check

Automatic calibrated scales height adjustable through telescopic bag support




Clamps each with a HF-sealing head

Telescopic bag support Graphical color display




 

Flow regulator unit with high precision optical detector

Keyboard

Scale

Pneumatic press with press position detection

Clamp with HF-sealing head for TAB processing

plasma: 260 g

sagm: 103 g

plasma: 155 g

air/plasma: 3g

Top angled press First phase: for high stability of layers; Second phase: for stable small rest volumes
1 2 3 4 5 6 7 8 9 10

Conventional quadruple bag

bc: 11 g

rbc: 75 g

Top-and-bottom bag

Press detection system with 10 precise sensors

Easy to use control buttons with LED indicators

T-ACE II+ Automatic Component Extractor


Data Management
TOMEs is an operational data management system that can be used with some Terumo Transfusion Equipment. By using TOMEs all GMP important separation data (e.g. net weight of components, date, time, barcode scans, events, etc.) are recorded and transferred via a wired (RJ-45 Ethernet) or wireless (WiFi) network. The separation data can be used to define specific production files for the customers Blood Bank Data Management System. Bi-directional communication with TOMEs allows the parameter setting of one or several T-ACE II+ devices, the automatic use of pre-defined separation protocols for each bag (if a separation file is defined), and the monitoring of active devices.
WiFi

TOMEs T-ACE II+ Ethernet Intranet

Optional Accessories
Product Name TOMEs* T-ACE II+ TOMEs** WiFi Module Router Wireless Router Air Compressor Filter Holder Hard Housing Filter Filter Holder Soft Housing Filter 220-240 V 100-120 V Hard Housing Filter Soft Housing Filter Codes ME-TOMES ME-TOMESTA2 ME+05TA2P02 ME+05TA2P23 ME+05TA2P24 ME+05TA08 ME+05TA72 ME-05TA2HF

Technical Specifications
Product Code Voltage Frequency Power Fuse ME-TACE2 50/60 Hz AC 100V to 240V 2 x 2 AT 50.5 cm (H) x 45.5 cm (W) x 53 cm (D) In working conditions the height is depending on the used length of the telescopic bag support (max. 69.5 cm). 32 kg 4-6 Bar Output: Maximum 150 W/50 Ohm/ Frequency: 40.68 MHz Crystal Barcode Reader and support RS-232 for barcode Reader RJ-45 (Ethernet) or Wireless Connection 2004/108/EC EN 61326-1 EMC Class A 2006/42/EC EN 61010-1 Safety


Size

Weight Inlet Pressure High Frequency Generator Accessories Communication Compliance with European Directives

ME-05TA2SF

* Terumo Operational Medical Equipment Software ** TOMEs Software License for T-ACE II+

Manufactured by: Terumo Europe N.V., 3001 Leuven, Belgium Distributed by: Terumo BCT

Terumo BCT, Inc. 10811 West Collins Ave. Lakewood, Colorado 80215-4440 USA USA Phone: 1. 877. 339.4228 Phone: +1. 303 . 231.4357 Fax: +1. 303 . 542 .5215

Terumo BCT Europe N.V. Europe, Middle East and Africa Ikaroslaan 41 1930 Zaventem Belgium Phone: +32.2.715.05.90 Fax: +32.2.721.07.70

Terumo BCT (Asia Pacific) Ltd. Room 3903-3903A, 39/F ACE Tower, Windsor House 311 Gloucester Road Causeway Bay, Hong Kong Phone: +852.2283.0700 Fax: +852.2576.1311

Terumo BCT Latin America S.A. La Pampa 1517 - 12th Floor C1428D2E Buenos Aires Argentina Phone: + 54.11.5530.5200 Fax: + 54.11.5530.5201

Terumo BCT Japan, Inc. Ebisu South One Bldg. 9F 1-7-8, Ebisu-minami, Shibuya-ku, Tokyo 150-0022 Japan Phone: +81.3.6743.7890 Fax: +81.3.6743.9800

UNLOCKING THE POTENTIAL OF BLOOD | TERUMOBCT.COM

2012 Terumo BCT, Inc. /PN 306620331

Вам также может понравиться