Вы находитесь на странице: 1из 5

INSTALACIONES EN BT Y CI PARA EDIFICIO DE NAVES INDUSTRIALES

Partner for Contact:


Order No.:
Company:
Customer No.:

Date: 03 / 07 / 2010
Operator:

INSTALACIONES EN BT Y CI PARA EDIFICIO DE NAVES INDUSTRIALES


03 / 07 / 2010

Operator
Telephone
Fax
e-Mail

ILUSOL 83263 SI 3 P 2x35W EL / Luminaire Data Sheet


Luminous emittance 1:
135

150

165

180

165

150

135

47

35

120

120

23
105

105

90

90

75

75

60

60

45

30

15

15

30

45

64%

cd/klm
C0 - C180

Luminaire classification according to CIE: 92


CIE flux code: 39 69 89 92 64
Waterproof fitting IP 66 with 'SALVASPAZIO' technologie.
Housing and diffuser in injected polycarbonate, autoextinguised and
stabilized
for the UV radiation. Housing in grey RAL 7035. Gasket in anti ageging
expanded polyuretane. Closing clips in fiber glass reforced with polyester
and
flush fitting with the body. The diffuser design reduce the transport and stock

C90 - C270

Luminous emittance 1:
Glare Evaluation According to UGR
Ceiling
Walls
Floor
Room Size
X
Y

70
50

70
30

50
50

50
30

30
30

70
50

70
30

50
50

50
30

30
30

20

20

20

20

20

20

20

20

20

20

Viewing direction at right angles


to lamp axis

Viewing direction parallel


to lamp axis

2H

2H
3H
4H
6H
8H
12H

18.9
20.9
21.8
22.7
23.1
23.5

20.2
22.1
22.9
23.7
24.1
24.4

19.3
21.3
22.3
23.2
23.6
24.0

20.6
22.5
23.4
24.2
24.6
24.9

21.0
22.9
23.8
24.7
25.1
25.4

17.1
18.4
18.8
19.1
19.2
19.2

18.5
19.6
20.0
20.2
20.2
20.2

17.5
18.8
19.3
19.6
19.6
19.7

18.8
20.0
20.4
20.6
20.7
20.6

19.3
20.5
20.9
21.1
21.2
21.2

4H

2H
3H
4H
6H
8H
12H

19.5
21.7
22.8
23.8
24.3
24.8

20.6
22.7
23.7
24.6
25.1
25.5

20.0
22.2
23.3
24.4
24.9
25.4

21.1
23.1
24.2
25.2
25.6
26.0

21.5
23.7
24.7
25.7
26.2
26.7

18.2
19.7
20.3
20.7
20.8
20.8

19.3
20.7
21.2
21.5
21.5
21.5

18.6
20.2
20.8
21.2
21.3
21.4

19.8
21.2
21.7
22.0
22.0
22.0

20.2
21.7
22.2
22.6
22.6
22.7

8H

4H
6H
8H
12H

23.1
24.3
25.0
25.7

23.8
25.0
25.5
26.1

23.6
24.9
25.6
26.3

24.3
25.5
26.1
26.7

24.9
26.2
26.8
27.4

21.0
21.6
21.8
22.0

21.7
22.2
22.4
22.4

21.5
22.2
22.4
22.6

22.2
22.8
23.0
23.1

22.8
23.4
23.6
23.7

12H

4H
6H
8H

23.1
24.4
25.1

23.7
25.0
25.6

23.6
25.0
25.8

24.3
25.6
26.2

24.9
26.2
26.9

21.1
21.9
22.2

21.8
22.4
22.7

21.7
22.5
22.8

22.3
23.0
23.3

22.9
23.7
24.0

volume: 3 fittings in one fitting package.

Variation of the observer position for the luminaire distances S

S = 1.0H
S = 1.5H
S = 2.0H

+0.1 / -0.1
+0.2 / -0.2
+0.3 / -0.4

+0.1 / -0.1
+0.2 / -0.3
+0.4 / -0.7

Standard table

BK09

BK06

Correction
Summand

7.5

3.1

Corrected Glare Indices referring to 7300lm Total Luminous Flux

DIALux 4.7 by DIAL GmbH

Page 2

INSTALACIONES EN BT Y CI PARA EDIFICIO DE NAVES INDUSTRIALES


03 / 07 / 2010

Operator
Telephone
Fax
e-Mail

GARAJE / Summary

157.93
157.93
157.93
157.93

157.93
157.93
157.93
157.93

157.93

157.93

157.93
157.93
157.93
157.93
157.93

157.93
157.93
157.93
157.93

157.93
157.93
157.93
157.93
157.93

157.93

10.86

157.93

157.93
157.93
157.93
157.93

157.93
157.93
157.93
157.93
157.93

14.50 ft

157.93
157.93
157.93
157.93

3.61

157.93
0.00

0.00

3.74

11.25

18.77

26.28

Height of Room: 3.000 ft, Mounting Height: 3.000 ft, Light loss factor: 0.80
Surface

30.00 ft

Values in Footcandles, Scale 1:66

[%]

Eav [fc]

Emin [fc]

Emax [fc]

u0

79

8.51

777

0.108

Floor

27

65

25

105

0.394

Ceiling

80

21

11

57

0.530

Walls (4)

27

39

21

55

Workplane

Workplane:
Height:
2.493 ft
Grid:
128 x 128 Points
Boundary Zone:
0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.388, Ceiling / Working Plane: 0.268.
Luminaire Parts List
No.

Pieces

Designation (Correction Factor)


ILUSOL 83263 SI 3 P 2x35W EL (1.000)
Total:

[lm]

P [W]

7300

70.0

58400

560.0

Specific connected load: 1.29 W/sq ft = 0.16 W/sq ft/10 fc (Ground area: 435.01 sq ft)

DIALux 4.7 by DIAL GmbH

Page 3

INSTALACIONES EN BT Y CI PARA EDIFICIO DE NAVES INDUSTRIALES


03 / 07 / 2010

Operator
Telephone
Fax
e-Mail

GARAJE / Input Protocol


Height of working plane: 2.493 ft
Boundary Zone: 0.000 ft

Light loss factor: 0.80


Height of Room: 3.000 ft
Ground area: 435.01 sq ft

Surface

Rho [%]

from ( [ft] | [ft] )

towards ( [ft] | [ft] )

Length [ft]

Floor

27

Ceiling

80

Wall 1

27

( 0.000 | 0.000 )

( 30.000 | 0.000 )

30.000

Wall 2

27

( 30.000 | 0.000 )

( 30.000 | 14.500 )

14.500

Wall 3

27

( 30.000 | 14.500 )

( 0.000 | 14.500 )

30.000

Wall 4

27

( 0.000 | 14.500 )

( 0.000 | 0.000 )

14.500

DIALux 4.7 by DIAL GmbH

Page 4

INSTALACIONES EN BT Y CI PARA EDIFICIO DE NAVES INDUSTRIALES


03 / 07 / 2010

Operator
Telephone
Fax
e-Mail

GARAJE / Luminaires (coordinates list)


ILUSOL 83263 SI 3 P 2x35W EL
7300 lm, 70.0 W, 1 x 2 x T5 / G5 (Correction Factor 1.000).

No.
1

X
3.740

Y
3.609

Z
3.000

X
0.0

Rotation []
Y
0.0

Z
0.0

3.740

10.859

3.000

0.0

0.0

0.0

11.253

3.609

3.000

0.0

0.0

0.0

11.253

10.859

3.000

0.0

0.0

0.0

18.766

3.609

3.000

0.0

0.0

0.0

6
7

18.766
26.279

10.859
3.609

3.000
3.000

0.0
0.0

0.0
0.0

0.0
0.0

26.279

10.859

3.000

0.0

0.0

0.0

DIALux 4.7 by DIAL GmbH

Position [ft]

Page 5

Вам также может понравиться