Вы находитесь на странице: 1из 66

Internal Use Only http://biz.lgservice.

com

Single Packaged Air Conditioner SVC MANUAL(Exploded View)


MODEL : LK-0580HC/BC LK-0580HC/BC(S1) LK-0580CC/AC LK-0580CC(S)/AC LK-0880HH/BH LK-0880BHS1 LK-0880CH/AH LK-1080HH/BH LK-1080CH/AH LK-1580HH/BH LK-1580CH/AH LK-2080CH/AH LK-1580AHS1
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.

Model Number Nomenclature


Table of contents
Model Number Nomenclature ............................................................................................................................... 2 General Data ........................................................................................................................................................... 3 Performance Data .................................................................................................................................................. 6 Electrical Requirements ...................................................................................................................................... 16 Dimensions ........................................................................................................................................................... 18 Wiring Diagram ..................................................................................................................................................... 24 Trouble Shooting Guide ...................................................................................................................................... 33 Electric Parts Trouble Shooting Guide .............................................................................................................. 37 Feature of Controller ........................................................................................................................................... 45 Exploded View ...................................................................................................................................................... 50 Specification of Components.............................................................................................................................. 56

Model Number Nomenclature

LK-08B0CH

C: Convertible H: Horizontal Flow D: Down Flow C: Cooling Only H: Heat Pump A: Gold Fin Outdoor Development Sequence 1 : 115/60/1 5 : 200-220/50/1 8 : 380-415/50/3 B : 220/60/3 2 : 220/60/1 6 : 220-240/50/1 9 : 380-415/60/3 C : 440-460/50/3 3 : 208-230/60/1 7 : 100/50(60)/1 A : 220/50/3 D : 440-460/60/3

03 : 3 ton 04 : 4 ton 05 : 5 ton 06 : 6.25 ton

Nominal cooling capacity 15 : 15 ton 08 : 7.5 ton 18 : 17.5 ton 09 : 8.5 ton 20 : 20 ton 10 : 10 ton 25 : 25 ton 13 : 12.5 ton

LG Single Package Air Conditioner

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

-2-

LGE Internal Use Only

General Data
Table-1
Nominal ton Models Electrical Data (Ton) ARI Net Cooling Capacity (BTU/hr) (W) (Kcal/h ) (V,PH) (Amps) (Watt) CFM (BTU/hr.W) bell 5 LK-0580CC(S)/AC 54,500 15,972 13,735 12.5 5,700 2,000 9.6 8.8 O(Accessory) O O O O O O O O O Reciprocating 1 High efficiency 0.375 9.52 2R/19FPI 54.3 1,380 12.07 1.12 High efficiency 0.375 9.52 3R/16FPI 18.3 465 4.83 0.45 Propeller 2EA/18" Direct 3,300 2/0.15 930 1EA 11"/11" Direct/2 1EA 0.3Hp/N.A 920/N.A 3/4" 1,280*1,065*1,110 220 485 7.5 LK-0880CH/AH 78,000 22,859 19,657 380/415V,3PH 20 8,500 2,600 9.2 8.8 O(Accessory) O O O O O O O O O washable & Anti-fungus Reciprocating 1 High efficiency 0.375 9.52 2R/16FPI 55.9 1,420 12.42 1.15 High efficiency 0.375 9.52 2R/16FPI 42.1 1,070 7.61 0.71 Propeller 1EA/24" Direct 4,000 1/0.5 950 Centrifugal Blower Fan 1EA 13"/13" Belt/1 1EA 1.5Hp/3.0Hp 1440/1440 3/4" 2,170*890*1,159 280 617

COOLING ONLY
10 LK-1080CH/AH 106,000 31,065 26,714 30 12,000 3,400 8.8 9.2 O(Accessory) O O O O O O O O O washable & Anti-fungus Reciprocating 2 High efficiency 0.375 9.52 2R/16FPI 66.9 1,700 17.66 1.64 High efficiency 0.375 9.52 3R/16FPI 37.9 963 9.48 0.88 Propeller 1EA/26" Direct 6,400 1/1.3 950 1EA 15"/11" Belt/1 1EA 3.0Hp/N.A 1440/N.A 3/4 2,170*1,050*1,550 330 728

Performance

Features

Compressor Outdoor Coil

Voltage M.C.A(with standard motor) Cooling Power Input Cooling Air Circulation Nominal CFM EER Cooling Sound Rating Cooling Wired Remote Controller Time Delay Safety Function Cooling Operation Mode Heating Operation Mode(with E/Heater) Soft Dry Operation Timer Setting (24-Hour on/off) Auto rastart mode Humidifier function Test function Self-Diagnosis Function Filter type Type Quantity Type Tube size(O.D) Row/FPI Lengh Face area

(inch) (mm) (inch) (mm) (sq.ft) (mm3) (inch) (mm) (inch) (mm) (sq.ft) (mm3)

Indoor Coil

Type Tube size(O.D) Row/FPI Lengh Face area

Type No. Used/Diameter(in.) Drive Type CFM No. Motor/Motor output(Hp) Motor RPM Indoor Fan Type No. Used Diameter/Width(in.) Drive Type/Motor Step No.motors Motor output(standard/oversized) Motor rpm(Standard/oversized) Drain Connection Size(in.) Dimensions Indoor unit (WxHxD) Weight net 1) Test Condition of ARI Rated Cooling Capacity : Ambient:95F , Air entering temprature : 80F DB and 67F WB 2) ARI standard 210/240 or 360 for EER 270 for Sound 3) The supply of filters is standard.

Outdoor Fan

(mm) (kg) (lbs)

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

-3-

LGE Internal Use Only

Table-2
Nominal ton Models Electrical Data (Ton) ARI Net Cooling Capacity (BTU/hr) (W) (Kcal/h ) (V,PH) (Amps) (Watt) CFM (BTU/hr.W) bell

COOLING ONLY
15 20 LK-1580CH/AH, LK-1580AHS1 LK-2080CH/AH 159,000 224,000 46,598 65,648 40,071 56,452 380/415V, 3PH 41.9 53.8 17,200 24,800 5,300 8,000 9.2 9 9.2 9.2 O(Accessory) O(Accessory) O O O O O O O O O O O O O O O O O O washable & Anti-fungus washable & Anti-fungus Reciprocating Reciprocating 2 2 High efficiency High efficiency 0.375 0.375 9.52 9.52 2R/16FPI 2R/16FPI 85 78.7 2,160 2,000 25.98 32.81 2.41 3.05 High efficiency High efficiency 0.375 0.375 9.52 9.52 2R/16FPI 2R/16FPI 55.1 55.9 1,400 1,420 16.08 23.29 1.49 2.16 Propeller Propeller 2EA/24" 2EA/26" Direct Direct 9,000 12,500 2/0.5 2/1.3 950 950 Centrifugal Blower Fan 1EA 1EA 15"/15" 18"/18" Belt/1 Belt/1 1EA 1EA 4.0Hp/5.0Hp 5Hp/7.5Hp 1440/2980 2980/2980 1" 1" 2,438*1,230*1,766 2,774*1,660*1,880 530 820 1168 1808

Performance

Features

Compressor Outdoor Coil

Voltage M.C.A(with standard motor) Cooling Power Input Cooling Air Circulation Nominal CFM EER Cooling Sound Rating Cooling Wired Remote Controller Time Delay Safety Function Cooling Operation Mode Heating Operation Mode(with E/Heater) Soft Dry Operation Timer Setting (24-Hour on/off) Auto rastart mode Humidifier function Test function Self-Diagnosis Function Filter type Type Quantity Type Tube size(O.D) Row/FPI Lengh Face area

(inch) (mm) (inch) (mm) (sq.ft) (mm3) (inch) (mm) (inch) (mm) (sq.ft) (mm3)

Indoor Coil

Type Tube size(O.D) Row/FPI Lengh Face area

Type No. Used/Diameter(in.) Drive Type CFM No. Motor/Motor output(Hp) Motor RPM Indoor Fan Type No. Used Diameter/Width(in.) Drive Type/Motor Step No.motors Motor output(standard/oversized) Motor rpm(Standard/oversized) Drain Connection Size(in.) Dimensions Indoor unit (WxHxD) Weight net

Outdoor Fan

(mm) (kg) (lbs)

1) Test Condition of ARI Rated Cooling Capacity : Ambient:95F , Air entering temprature : 80F DB and 67F WB 2) ARI standard 210/240 or 360 for EER 270 for Sound 3) The supply of filters is standard.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

-4-

LGE Internal Use Only

Table-3
Nominal ton Models Capacity (Ton) ARI Net Cooling Capacity (BTU/hr) (W) (Kcal/h) (BTU/hr) (W) (Kcal/h) (V,PH) (Amps) (Amps) (Watt) (Watt) CFM (BTU/hr.W) (BTU/hr.W) bell

HEAT-PUMP
5 7.5 10 15 LK-0580HC/BC(S1) LK-0880HH/0880BH/0880BHS1 LK-1080HH/1080BH LK-1580HH/1580BH 53,000 73,000 100,000 152,000 15,533 21,394 29,307 44,547 13,357 18,397 25,202 38,306 53,000 73,000 92,000 150,000 15,533 21,394 26,962 43,961 13,357 18,397 23,185 37,802 380/415V,3PH 12.5 20 27 40.6 10.6 18.2 24.5 36.9 5,700 8,500 12,000 17,000 4,750 7,100 9,800 14,300 2,000 2,600 3,400 5,300 9.3 8.6 8.3 8.9 11.2 10.3 9.4 10.5 8.8 8.8 9.2 9.2 O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O washable & Anti-fungus washable & Anti-fungus washable & Anti-fungus Reciprocating Reciprocating Reciprocating Reciprocating 1 1 2 2 High efficiency High efficiency High efficiency High efficiency 0.375 0.375 0.375 0.375 9.52 9.52 9.52 9.52 2R/19FPI 2R/16FPI 2R/16FPI 2R/16FPI 54.3 55.9 66.9 85 1,380 1,420 1,700 2,160 12.07 12.42 17.66 25.98 1.12 1.15 1.64 2.41 High efficiency High efficiency High efficiency High efficiency 0.375 0.375 0.375 0.375 9.52 9.52 9.52 9.52 3R/16FPI 2R/16FPI 2R/16FPI 2R/16FPI 18.3 42.1 37.9 55.1 465 1,070 963 1,400 4.83 7.61 9.48 16.08 0.45 0.71 0.88 1.49 Propeller Propeller Propeller Propeller 2EA/18" 1EA/26" 1EA/26" 2EA/26" Direct Direct Direct Direct 3,300 5,900 6,400 9,000 2/0.15 1/0.5 1/1.3 2/1.3 930 950 950 950 Centrifugal Blower Fan 1EA 1EA 1EA 1EA 11"/11" 13"/13" 15"/11" 15"/15" Direct/2 Belt/1 Belt/1 Belt/1 1EA 1EA 1EA 1EA 0.3Hp/N.A 1.5Hp/3.0Hp 3.0Hp/N.A 4.0Hp/5.0Hp 920/N.A 1440/1440 1440/N.A 1440/2980 3/4 3/4 3/4 1 1,280*1,065*1,110 2,170*890*1,159 2,170*1,050*1,550 2,438*1,230*1,766 220 280 330 530 485 617 728 1168

Heating Capacity

Electrical Data

Voltage M.C.A(with standard motor) Power Input

Performance

Air Circulation EER

Cooling Heating Cooling Heating Nominal CFM Cooling Heating

Features

Compressor Outdoor Coil

Sound Rating Wired Remote Controller Time Delay Safety Function Cooling Operation Mode Heating Operation Mode(with E/Heater) Soft Dry Operation Timer Setting (24-Hour on/off) Auto rastart mode Humidifier function Test function Defrost Hot Start Self-Diagnosis Function Filter type Type Quantity Type Tube size(O.D) Row/FPI Lengh Face area

(inch) (mm) (inch) (mm) (sq.ft) (mm3) (inch) (mm) (inch) (mm) (sq.ft) (mm3)

Indoor Coil

Type Tube size(O.D) Row/FPI Lengh Face area

Outdoor Fan

Type No. Used/Diameter(in.) Drive Type CFM No. Motor/Motor output(Hp) Motor RPM Indoor Fan Type No. Used Diameter/Width(in.) Drive Type/Motor Step No.motors Motor output(standard/oversized) Motor rpm(Standard/oversized) Drain Connection Size(in.) Dimensions Indoor unit (WxHxD) Weight net

(mm) (kg) (lbs)

1) Test Condition of ARI Rated Cooling Capacity : Ambient:95F , Air entering temprature : 80F DB and 67F WB Test Condition of Heating Capacity : Outdoor entering Temperature : 44.6F DB and 42.8F WB95F Indoor Air entering temprature : 68F DB and 59F WB 2) ARI standard 210/240 or 360 for EER 270 for Sound 3) The supply of filters is standard.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

-5-

LGE Internal Use Only

Performance data
Table-1
L/s 802 849 897 944 991 1038 1085 1133 Supply Fan Performance LK-0580AC/0580CC(S)/0580HC/LK-0580BC(S1)(SI) High Speed ESP 22.27 19.68 17.09 14.49 11.90 9.30 6.71 4.12 BkW 0.38 0.41 0.45 0.48 0.52 0.56 0.59 0.63 ESP 21.19 17.25 13.32 9.39 5.46 1.53 Mid Speed BkW 0.33 0.37 0.40 0.43 0.47 0.50 ESP 7.52 0.75 Low Speed BkW 0.38 0.42 -

Fan motor heat = 2 x BkW Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.

Table-2
CFM 1,700 1,800 1,900 2,000 2,100 2,200 2,300 2,400

Supply Fan Performance LK-0580AC/0580CC(S)/0580HC/LK-0580BC(S1) (English) High Speed ESP 0.85 0.77 0.67 0.57 0.51 0.41 0.26 0.11 BHP 0.54 0.55 0.59 0.65 0.67 0.72 0.80 0.89 ESP 0.79 0.68 0.59 0.37 0.23 0.06 Mid Speed BHP 0.44 0.49 0.54 0.58 0.63 0.67 ESP 0.30 0.03 Low Speed BHP 0.51 0.56 -

Fan motor heat(MBH)= 5.09 x Fan Bhp Test Condition: Voltage :380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

-6-

LGE Internal Use Only

Table-3
L/s

Supply Fan Performance LK-0880AH/0880BH/0880BHS1/0880CH/0880HH (SI)

External Static Pressure(inches of water) 2.5 5.1 7.6 10.2 12.7 15.2 17.8 20.3 22.9 25.4 31.8 38.1 RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW
1.5 STANDARD MOTOR & DRIVE

982 1104 1227 1350 1472

645 0.19 668 0.24 691 0.28 714 0.33 738 0.38 761 0.42 784 0.47 807 0.51 830 0.56 854 0.6 912 0.72 970 0.83 676 0.31 699 0.36 722 711 0.45 734 0.4 746 0.45 769 0.5 792 0.54 815 0.59 838 0.63 862 0.68 885 0.72 943 0.84 1001 0.95 866 0.85 889 0.89 912 0.94 935 0.98 958 1.03 1016 1.14 1074 1.26
3Hp OVERSIZE MOTOR & DRIVE

0.5 757 0.55 781 0.59 804 0.64 827 0.68 850 0.73 873 0.77 897 0.82 920 0.87 978 0.98 1036 1.09 0.9 861 0.94 885 0.99 908 1.04 931 1.08 954 1.13 977 1.17 1001 1.22 1059 1.33 1117 1.45

749 0.62 773 0.66 796 0.71 819 0.76 842 0.8 792 0.81 815 0.85 838

Fan motor heat(MBH)= 1.28 x Fan BkW Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.

Table-4
CFM

Supply Fan Performance LK-0880AH/0880BH/0880BHS1/0880CH/0880HH (English)

External Static Pressure(inches of water) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.25 1.5 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
1.5 STANDARD MOTOR & DRIVE

2080 2340 2600 2860 3120

645 0.26 668 0.32 691 0.38 714 0.44 738 0.5

761 0.56 784 0.63 807 0.69 830 0.75 854 0.81 912 0.96 970 1.12 1.1 920 1.16 978 1.31 1036 1.47

676 0.42 699 0.48 722 0.54 746 0.6 769 0.66 792 0.73 815 0.79 838 0.85 862 0.91 885 0.97 943 1.12 1001 1.28 711 0.61 734 0.67 757 0.73 781 0.79 804 0.85 827 0.92 850 0.98 873 1.04 897 792 1.08 815 1.14 838 749 0.83 773 0.89 796 0.95 819 1.01 842 1.07 866 1.14 889 1.2 912 1.26 935 1.32 958 1.38 1016 1.53 1074 1.69 1.2 861 1.27 885 1.33 908 1.39 931 1.45 954 1.51 977 1.57 1001 1.63 1059 1.79 1117 1.94
3Hp OVERSIZE MOTOR & DRIVE

Fan motor heat(kW)= 3.26 x Fan Bhp Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.

Table-5

Fan speed Data LK-0880AH/0880BH/0880BHS1/0880CH/0880HH

6 Turn Open 5 Turn Open 4 Turn Open 3 Turn Open 2 Turn Open 1 Turn Open
Standard Motor & Drive Fan Speed Over size Motor & Drive Fan Speed

Closed 946 1104

644 751

694 810

745 869

795 928

845 986

896 1045

Factory set at 3 turns open.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

-7-

LGE Internal Use Only

Table-6
CFM

Supply Fan Performance LK-1080AH/1080BH/1080CH/1080HH (English)

External Static Pressure(inches of water) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
3Hp STANDARD MOTOR & DRIVE

2720 3060 3400 3740 4080

609 0.53 615 0.53 623 0.62 632 0.67 642 0.72 653 0.76 665 0.81 678 0.85 693 0.90 707 0.94 722.9 0.99 739 1.03 640 0.75 645 0.80 653 0.84 662 0.89 672 0.93 684 0.98 696 1.02 709 1.07 723 1.11 738 1.16 753.4 1.21 770 1.25 676 1.01 682 1.06 689 1.10 698 1.15 708 1.19 720 1.24 732 1.28 745 1.33 759 1.37 774 1.42 789.4 1.46 806 1.51 718 1.31 723 1.35 731 1.40 740 1.44 750 1.49 761 1.54 774 1.58 787 1.63 801 1.67 816 1.72 831.3 1.76 848 1.81 765 1.65 771 1.70 779 1.74 788 1.79 798 1.83 809 1.88 822 1.92 835 1.97 849 2.01 864 2.06 879.3 2.10 896 2.15

CFM

External Static Pressure(inches of water) 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
3Hp STANDARD MOTOR & DRIVE

2720 3060 3400 3740 4080

756 1.08 774 1.12 792 1.17 811 1.21 831 1.26 851 1.30 872 1.35 893 1.39 787 1.30 804 1.34 823 1.39 842 1.43 861 1.48 881 1.52 902 1.57 923 1.61 823 1.55 840 1.60 859 1.64 878 1.69 897 1.73 917 1.78 938 1.82 959 1.87 865 1.85 882 1.90 901 1.94 920 1.99 939 2.03 959 2.08 980 2.12 1001 2.17 913 2.20 930 2.24 949 2.29 968 2.33 987 2.38 1007 2.42 1028 2.47
3Hp STANDARD MOTOR & HIGH STATIC DRIVE

Fan motor heat(MBH)= 3.1 x Fan Bhp Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

-8-

LGE Internal Use Only

Table-7
L/s

Evaporator Fan Performance LK-1080AH/1080BH/1080CH/1080HH (SI)

External Static Pressure(mm aq.) 2.5 5.1 7.6 10.2 12.7 15.2 17.8 20.3 22.9 25.4 27.9 30.5 RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW
3Hp STANDARD MOTOR & DRIVE

1284 1444 1605 1765 1925

609 0.40 615 0.43 623 0.47 632 0.50 642 0.53 653 0.57 665 0.60 678 0.63 693 0.67 707 0.70 722.9 0.74 739 0.77 640 0.56 645 0.59 653 0.63 662 0.66 672 0.70 684 0.73 696 0.76 709 0.80 723 0.83 738 0.86 753.4 0.90 770 0.93 676 0.75 682 0.79 689 0.82 698 0.85 708 0.89 720 0.92 732 0.96 745 0.99 759 1.02 774 1.06 789.4 1.09 806 1.12 718 0.98 723 1.01 731 1.04 740 1.08 750 1.11 761 1.15 774 1.18 787 1.21 801 1.25 816 1.28 831.3 1.31 848 1.35 765 1.23 771 1.27 779 1.30 788 1.33 798 1.37 809 1.40 822 1.43 835 1.47 849 1.50 864 1.54 879.3 1.57 896 1.60

L/s

External Static Pressure(mm aq.) 33.0 35.6 38.1 40.6 43.2 45.7 48.3 50.8 RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW
3Hp STANDARD MOTOR & DRIVE

1284 1444 1605 1765 1925

756 0.80 774 0.84 792 0.87 811 0.90 831 0.94 851 0.97 872 1.10 893 1.04 787 0.97 804 1.00 823 1.03 842 1.07 861 1.10 881 1.13 902 1.17 923 1.20 823 1.16 840 1.19 859 1.23 878 1.26 897 1.29 917 1.33 938 1.36 959 1.39 865 1.38 882 1.42 901 1.45 920 1.48 939 1.52 959 1.55 980 1.58 1001 1.62 913 1.64 930 1.67 949 1.70 968 1.74 987 1.77 1007 1.81 1028 1.84
3Hp STANDARD MOTOR & HIGH STATIC DRIVE

Fan motor heat(kW)= 1.22 x Fan BkW Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.

Table-8

Fan speed Data LK-1080AH/1080BH/1080CH/1080HH

6 Turn Open 5 Turn Open 4 Turn Open 3 Turn Open 2 Turn Open 1 Turn Open
Standard Motor & Drive Fan Speed Standard Motor & High Static Drive Accessory Fan Speed

Closed 813 1046

576 742

615 793

655 843

694 894

734 945

773 996

Factory set at 3 turns open.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

-9-

LGE Internal Use Only

Table-9
CFM

Evaporator Fan Performance LK-1580AH/1580BH/1580CH/1580HH (English)

External Static Pressure(inches of water) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
4Hp STANDARD MOTOR & DRIVE

4240 4770 5300 5830 6360

624 1.21 641 1.28 658 1.36 674 1.43 691 1.51 708 1.58 725 1.66 742 1.73 759 1.81 775 1.88 792 1.95

643 1.56 660 1.63 677 1.71 694 1.78 711 1.86 728 1.93 745 2.01 761 2.08 778 2.16 795 2.23 812 2.31 829 2.38 686 2.06 703 2.13 720 2.21 737 2.28 754 2.36 771 2.43 788 2.51 804 2.58 821 2.66 838 2.73 855 2.81 872 2.88 736 2.64 753 2.72 770 2.79 787 2.87 804 2.94 821 3.02 838 3.09 854 3.17 871 3.24 888 3.32 905 3.39 922 3.47 794 3.31 811 3.39 827 3.46 844 3.54 861 3.61 878 3.69 895 3.76 912 3.84 929 3.91 945 3.99 962 4.06 979 4.14

CFM

External Static Pressure(inches of water) 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
4Hp STANDARD MOTOR & DRIVE

4240 4770 5300 5830 6360

809 2.03 826 2.10 843 2.18 860 2.25 877 2.33 893 2.40 910 2.48 927 2.55 846 2.46 862 2.53 879 2.60 896 2.68 913 2.75 930 2.83 947 2.90 964 2.98 889 2.96 905 3.03 922 3.11 939 3.18 956 3.26 973 3.33 990 3.41 1007 3.48 939 3.54 955 3.62 972 3.69 989 3.77 1006 3.84 1023 3.92 1040 3.99 1057 4.07 996 4.21 1013 4.29 1030 4.36 1046 4.44 1063 4.51 1080 4.59 1097 4.66 1114 4.74
5Hp OVER SIZE MOTOR & DRIVE 4Hp STANDARD MOTOR & HIGH STATIC DRIVE

Fan motor heat(MBH)= 3.1 x Fan Bhp Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 10 -

LGE Internal Use Only

Table-10
L/s

Evaporator Fan Performance LK-1580AH/1580BH/1580CH/1580HH (SI)

External Static Pressure(mm aq.) 2.5 5.1 7.6 10.2 12.7 15.2 17.8 20.3 22.9 25.4 27.9 30.5 RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW 624 0.90 641 0.96 658 1.01 674 1.07 691 1.12 708 1.18 725 1.23 742 1.29 759 1.35 775 1.40 792 1.46 754 1.76 771 1.82 788 1.87 804 1.93 821 1.98 838 2.04 855 2.09 872 2.15

2001 2251 2501 2751 3002

643 1.16 660 1.22 677 1.27 694 1.33 711 1.38 728 1.44 745 1.50 761 1.55 778 1.61 795 1.66 812 1.72 829 1.78 686 1.54 703 1.59 720 1.65 737 1.7 736 1.97 753 2.03 770 2.08 787 2.14 804 2.2 821 2.25 838 2.31 854 2.36 871 2.42 888 2.47 905 2.53 922 2.59 794 2.47 811 2.53 827 2.58 844 2.64 861 2.69 878 2.75 895 2.81 912 2.86 929 2.92 945 2.97 962 3.03 979 3.09

L/s

External Static Pressure(mm aq.) 33.0 35.6 38.1 40.6 43.2 45.7 48.3 50.8 RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW 809 1.51 826 1.57 843 1.63 860 1.68 877 1.74 893 1.79 910 1.85 927 1.90 846 1.83 862 1.89 879 1.94 896 2.00 913 2.05 930 2.11 947 2.17 964 2.22 889 2.21 905 2.26 922 2.32 939 2.37 956 2.43 973 2.49 990 2.54 1007 2.6 939 2.64 955 2.70 972 2.75 989 2.81 1006 2.86 1023 2.92 1040 2.98 1057 3.03 996 3.14 1013 3.2 1030 3.25 1046 3.31 1063 3.36 1080 3.42 1097 3.48 1114 3.53
5Hp OVER SIZE MOTOR & DRIVE 4Hp STANDARD MOTOR & HIGH STATIC DRIVE

2001 2251 2501 2751 3002

Fan motor heat(kW)= 1.22 x Fan BkW Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.

Table-11

Fan speed Data LK-1580AH/1580BH/1580CH/1580HH 6 Turn Open 5 Turn Open 4 Turn Open 3 Turn Open 2 Turn Open 1 Turn Open 0 Turn Open

Standard Motor & Drive Fan Speed Standard Motor & High Static Drive Accessory Fan Speed Over Size Motor & Drive Fan Speed

610 742 882

562 793 942

694 843 1,002

735 894 1,063

777 945 1,123

819 996 1,183

861 1,046 1,244

Factory set at 3 turns open.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 11 -

LGE Internal Use Only

Table-12
CFM

Evaporator Fan Performance LK-2080AH/2080CH (English)

External Static Pressure(inches of water) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
5Hp STANDARD MOTOR & DRIVE

6400 7200 8000 8800 9600

477 1.18 502 1.34 526 1.51 549 1.68 573 1.87 598 2.08 620 2.30 644 2.50

497 1.68 522 1.88 545 2.06 567 2.23 589 2.42 610 2.61 638 2.80 649 3.02 671 3.25

488 2.00 517 2.23 544 2.47 568 2.70 590 2.93 611 3.13 631 3.32 651 3.52 670 3.72 687 3.94 706 4.16

507 2.72 538 2.90 565 3.15 590 3.40 614 3.66 636 3.93 656 4.17 675 4.40 694 4.62 712 4.83 728 5.05 745 5.28 559 3.74 587 3.90 613 4.24 637 4.51 660 4.79 682 5.08 702 5.36 721 5.64 739 5.89 756 6.13 772 6.37 787 6.61

CFM

External Static Pressure(inches of water) 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
5Hp STANDARD MOTOR & DRIVE

6400 7200 8000 8800 9600

666 2.70 687 2.89 709 3.11 731 3.34 753 3.57 773 3.80 793 4.03 812 4.27 693 3.48 713 3.72 736 3.94 756 4.17 774 4.39 793 4.62 813 4.86 833 5.12 724 4.38 741 4.62 763 4.88 783 5.14 803 5.40 822 5.66 840 5.91 858 6.16 763 5.51 778 5.75 797 5.99 814 6.24 831 6.50 849 6.79 869 7.07 887 7.28 804 6.94 818 7.09 836 7.34 852 7.59 862 7.85 880 8.14 900 8.42 918 863
7.5Hp OVER SIZE MOTOR & DRIVE 5Hp STANDARD MOTOR & HIGH STATIC DRIVE

Fan motor heat(MBH)= 3.1 x Fan Bhp Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater. Do not operate the unit at a cooling airflow that is less then 350cfm/1.2MBH.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 12 -

LGE Internal Use Only

Table-13
L/s

Evaporator Fan Performance LK-2080AH/2080CH (SI)

External Static Pressure(mm aq.) 2.5 5.1 7.6 10.2 12.7 15.2 17.8 20.3 22.9 25.4 27.9 30.5 RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW 477 0.88 502 1.00 526 1.13 549 1.25 573 1.39 598 1.55 620 1.72 644 1.86

3020 3398 3776 4153 4531

497 1.25 522 1.40 545 1.54 567 1.66 589 1.80 610 1.95 638 2.09 649 2.25 671 2.42

488 1.49 517 1.66 544 1.84 568 2.01 590 2.18 611 2.33 631 2.48 651 2.62 670 2.77 687 2.94 706 3.10

507 2.03 538 2.16 565 2.35 590 2.54 614 2.73 636 2.93 656 3.11 675 3.28 694 3.45 712 3.60 728 3.77 745 3.94 559 2.79 587 2.91 613 3.16 637 3.36 660 3.57 682 3.79 702 4.00 721 4.21 739 4.39 756 4.57 772 4.75 787 4.93

L/s

External Static Pressure(mm aq.) 33.0 35.6 38.1 40.6 43.2 45.7 48.3 50.8 RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW 666 2.01 687 2.16 709 2.32 731 2.49 753 2.66 773 2.83 793 3.01 812 3.18 693 2.6 713 2.77 736 2.94 756 3.11 774 3.27 793 3.45 813 3.62 833 3.82 724 3.27 741 3.45 763 3.64 783 3.83 803 4.03 822 4.22 840 4.41 858 4.59 763 4.11 778 4.29 797 4.47 814 4.65 831 4.85 849 5.06 869 5.27 887 5.43 804 5.18 818 5.29 836 5.47 852 5.66 862 5.85 880 6.07 900 6.28 918 6.44
7.5Hp OVER SIZE MOTOR & DRIVE 5Hp STANDARD MOTOR & HIGH STATIC DRIVE

3020 3398 3776 4153 4531

Fan motor heat(kW)= 1.22 x Fan BkW Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater. Do not operate the unit at a cooling airflow that is less then 350cfm/1.2MBH.

Table-14

Fan speed Data LK-2080CH

6 Turn Open 5 Turn Open 4 Turn Open 3 Turn Open 2 Turn Open 1 Turn Open 0 Turn Open
Standard Motor & Drive Fan Speed Standard Motor & High Static Drive Accessory Fan Speed Over Size Motor & Drive Fan Speed

492 636 749

525 678 798

557 720 848

590 763 898

623 805 948

655 847 998

688 890 1048

Factory set at 3 turns open.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 13 -

LGE Internal Use Only

Table-15
Unit Model No. cfm
1600 2000 2400 LK-0880HH 2340 LK-0880BH/BHS1 2600 LK-0880CH/AH 2860 LK-1080HH 2720 LK-1080BH 3420 LK-1080CH/AH 4080 LK-1580CH/AH 4240 LK-1580BH 5300 LK-1580HH 6360 6400 8000 LK-2080CH 9600 LK-0580HC/BC(S1) LK-0580CC(S)/AC

Accessory Static Pressure Drops

L/s
755 944 1130 982 1227 1472 1284 1605 1705 2001 2501 3002 3020 3776 4531

Standard Filter
in Aq 0.03 0.05 0.07 0.04 0.08 0.12 0.06 0.10 0.14 0.06 0.09 0.13 0.07 0.1 0.14

Electric Heater
9KW in Aq mm Aq 0.01 0.25 0.01 0.25 0.02 0.51 0.01 0.25 0.01 0.25 0.02 0.51 10KW in Aq mm Aq 0.02 0.51 0.04 1.02 0.05 1.27 15KW in Aq mm Aq 0.03 0.76 0.06 1.52 0.09 2.29 18KW in Aq mm Aq 0.02 0.51 0.03 0.76 0.04 1.02 0.07 1.78 0.10 2.54 0.15 2.81 0.04 1.02 0.06 1.52 0.1 2.54 36KW in Aq mm Aq 0.04 1.02 0.07 1.78 0.10 2.54 0.1 2.54 0.13 3.30 0.18 4.57 0.04 1.02 0.07 1.78 0.11 2.79 0.07 1.78 0.13 3.30 0.17 4.32

5KW mm Aq in Aq mm Aq 0.76 0.02 0.51 1.27 0.03 0.76 1.78 0.04 1.02 1.02 2.03 3.05 1.52 2.54 3.30 1.52 2.29 3.30 1.78 2.57 3.56 -

Table-16
MODEL
LK-0580HC/BC(S1) LK-0580CC(S)/AC LK-0880HH LK-0880BH/BHS1 LK-0880CH/AH LK-1080HH LK-1080BH LK-1080CH/AH
LK-1580CH/AH LK-1580BH LK-1580HH

Electric Heating Capacity Stage 1 Output(MBH)


17.07 34.14 68.28 30.72 61.43 61.43 30.72 61.43 61.43 61.43 61.43 61.43

Total Input(KW) Output(MBH)


5 10 15 9 18 36 9 18 36 18 36 36 17.07 34.14 68.28 30.72 61.43 122.86 30.72 61.43 122.86 61.43 122.86 245.72

No. of Stages
1 1 1 1 1 2 1 1 2 1 2 2

Input(kw)
5 10 15 9 18 18 9 18 18 18 18 18

Stage 2 Input(kw) Output(MBH)


18 18 18 18 61.43 61.43 61.43 61.43

LK-2080CH/AH

Note: 1. The output ratings shown above is at 240V. For other voltage, Output = Capacity Multiplier x Rated Output 2. E/heater Voltage range is 380~415V.

< Correction Coefficent >

Voltage 380 400 415

Capacity Multiplier 0.84 0.92 1.0

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 14 -

LGE Internal Use Only

Table-17

Air Temperature Rise Across Electric Heater(F)


LK-0580BC(S1) LK-0580AC LK-0580CC(S) LK-0580HC (2000CFM) LK-0880AH LK-0880BH LK-0880BHS1 LK-0880CH LK-0880HH (2600CFM) LK-1080AH LK-1080BH LK-1080CH LK-1080HH (3400CFM) LK-1580AH LK-1580CH LK-1580BH LK-1580HH (5300CFM)

Capacity

Stage

LK-2080B0AC LK-2080B0CC (8000CFM)

5KW 9KW 10KW 18KW 36KW

1 1 1 1 2

7.9 15.8 -

10.9 21.9 32.7

14.3 28.5 42.9

10.7 21.5

14.2

Temp. Rise across Electric Heater =

(KW x 3413) (1.08 x CFM) If you want to take temp rise at different airflow use above equation.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 15 -

LGE Internal Use Only

Electrical Requirements
Table-18
Tons 5 7.5 10 15 20 MODEL LK-0580HC/BC(S1) LK-0580CC(S)/AC LK-0880HH/BH LK-0880BHS1 LK-0880CH/AH LK-1080HH/BH LK-1080CH/AH LK-1580HH/BH LK-1580CH/AH LK-2080CH/AH Electrical Data Unit wiring Unit Operating Voltage Range 342~456 342~456 342~456 342-456 342-456 Standard indoor fan motor M.C.A. M.F.S. M.C.B 12.5 25 25 12.5 25 25 20 20 27 30 40.6 41.9 53.8 25 25 35 35 60 60 70 25 25 35 35 60 60 70 Oversized indoor fan motor M.C.A. M.F.S. M.C.B 23 23 43 45 62 25 25 60 60 80 25 25 60 60 80

Table-19
Tons LK-0580HC/BC(S1) LK-0580CC(S)/AC LK-0880HH LK-0880BH LK-0880BHS1 LK-0880CH/AH LK-1080HH LK-1080BH LK-1080CH/AH LK-1580CH/AH LK-1580HH LK-1580BH LK-2080HH MODEL 5 10 9 18 36 9 18 36 9 18 36 18 36 18 36 36

Electrical Data Unit wiring with electric heater. Unit Operating Voltage Range 3,380/415V, 50Hz 3,380/415V, 50Hz 3,380/415V, 50Hz 3,380/415V, 50Hz 3,380/415V, 50Hz 3,380/415V, 50Hz 3,380/415V, 50Hz Standard indoor fan motor M.C.A. M.F.S. M.C.B 21 25 25 28 35 35 32.5 45 45 45 60 60 58 70 70 42.5 45 45 55 60 60 68 70 70 40.5 45 45 52 60 60 65 70 70 58 70 70 71 90 90 58 70 70 71 90 90 72 90 90 Oversized indoor fan motor M.C.A. M.F.S. M.C.B 35.5 45 45 48 60 60 61 70 70 60 70 70 73 90 90 60 70 70 73 90 90 77 90 90

Note: Heater kW ratings are at 380/415 V unit.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 16 -

LGE Internal Use Only

Table-20
MODEL LK-0580HC/BC(S1) LK-0580CC(S)/AC LK-0880HH/BH LK-0880BHS1 LK-0880CH/AH LK-1080HH/BH LK-1080CH/AH LK-1580HH/BH LK-1580CH/AH LK-2080CH/AH No 1

Electrical characteristics --- Evaporator Fan Motor --- 50 Hz Standard evaporator fan motor volts Phase 380~415 3 HP 0.75 FLA 1.9 LRA 2.5 No Oversized evaporator fan motor volts Phase HP FLA -

LRA -

380~415

1.5

2.6

7.3

380~415

3.4

10.8

1 1 1

380~415 380~415 380~415

3 3 3

3 4 5

3.4 6.5 7.1

10.8 26 42

1 1

380~415 380~415

3 3

5 7.5

7.1 11.2

42 63

Table-21
MODEL LK-0580HC/BC(S1) LK-0580CC(S)/AC LK-0880HH/BH LK-0880BHS1 LK-0880CH/AH LK-1080HH/BH LK-1080CH/AH LK-1580HH/BH LK-1580CH/AH LK-2080CH/AH No 1

Electrical characteristics --- Compressor and Outdoor Fan Motor --- 50 Hz Compressor volts Phase 380~415 3 HP 6 FLA 9.2 LRA 79 No 2 Outdoor Fan Motor volts Phase HP FLA 220~240 220~240 380~415 1 1 3 1 1 3 1 0.15 1.3 0.5 1.3 1.3 0.5 1.3 1.5 6.2 1.5 6.2 6.2 1.5 6.2

LRA 10.8 19.5 2.3 19.5 19.5 2.3 19.5

380~415

8.5

15

115

2 2 2

380~415 380~415 380~415

3 3 3

6 8.5 12

9.2 15 21.6

79 115 126

1 1 1

380~415 220~240 220~240

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 17 -

LGE Internal Use Only

Dimensions
LK-0580AC/0580CC(S)/0580HC/0580BC(S1)

UNITS A B C D E F G

Unit: inch(mm) 5RT 41.93(1065) 43.70(1110) 50.39(1280) 29.49(749) 9.65(245) 2.36(60) 2.76(70)
Center Line of Hole

CLEARANCE 34" CLEARANCE 16"(HORIZONTAL) CLEARANCE 32"(DOWNFLOW)

F E A

CLEARANCE 34"

G D 1" Dia. Hole Control Wires 1.5" Dia. Hole Power Wires 1.5" Dia. Hole Other Purpose C B

CLEARANCE 46"

UNITS H J K L M N P

Unit: inch(mm) 5RT 13.86(352) 9.21(234) 10.47(266) 3.86(98)

RETURN

SUPPLY

4.33(110) 22.28(566) 16.38(416)

M H J K L

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 18 -

LGE Internal Use Only

LK-0880AH/0880BH/0880BHS1/0880CH/0880HH
Unit: inch(mm) UNITS A B C D E F G LK-0880AH/0880BH/0880BHS1/ 0880CH/0880HH 35.04(890) 46.93(1159) 85.43(2170) 10.43(265) 2.76(70) 2.36(60) 3.54(90)
Center Line of Hole 1.5" Dia. Hole Other Purpose 1.5" Dia. Hole Power Wires 1" Dia. Hole Control Wires C G B F D E L A

CLEARANCE 34" CLEARANCE 16"

CLEARANCE 34"

CLEARANCE 46"

Unit: inch(mm) LK-0880AH/0880BH/0880BHS1/ UNITS 0880CH/0880HH H 15.47(393) J K L M N 16.18(411) 18.82(478) 2.40(61) 5.35(136) 26.89(683)

S U P P L Y
H J

R E T U R N
K L

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 19 -

LGE Internal Use Only

LK-1080AH/1080CH/1080HH
Unit: inch(mm) UNITS LK-1080AH/1080CH/1080HH A B C D E F G 41.34(1050) 48.89(1242) 85.43(2170) 55.0(1397) 6.10(155)
Center Line of Hole G F E

CLEARANCE 34"

CLEARANCE 16"(HORIZONTAL)

CLEARANCE 34"
D A

8.46(215) 10.43(265)

C 1" Dia. Hole Control Wires 1.5" Dia. Hole Power Wires 1.5" Dia. Hole Other Purpose B

CLEARANCE 46"

Unit: inch(mm) UNITS LK-1080AH/1080CH/1080HH H J K L M N 16.06(408) 14.02(356) 20.16(512) 2.44(62) 2.01(51) 34.33(872)

S U P P L Y
H J

R E T U R N
K L

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 20 -

LGE Internal Use Only

LK-1580AH/1580CH/1580HH
Unit: inch(mm) UNITS LK-1580AH/1580CH/1580HH A B C D E F G 47.44(1205) 69.53(1766) 95.98(2438) 63.11(1603) 6.29(160) 8.66(220) 11.02(280)
Center Line of Hole
D C G F E A

CLEARANCE 34"

CLEARANCE 16"(HORIZONTAL)

CLEARANCE 34"

1" Dia. Hole Control Wires 1.5" Dia. Hole Power Wires 1.5" Dia. Hole Other Purpose

CLEARANCE 46"

Unit: inch(mm) UNITS LK-1580AH/1580CH/1580HH 24.53(623) H I J K L M 9.17(233) 24.53(623) 2.36(60) 5.08(129) 40.24(1022)

S U P P L Y
H I

R E T U R N
J

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 21 -

LGE Internal Use Only

LK-2080AH/2080CH
Unit: inch(mm) LK-2080AH/2080CH 65.35(1660) 74.02(1880) 109.21(2774) 69.69(1770) 7.68(195) 11.89(302)
Center Line of Hole
D C F E A

UNITS A B C D E F

CLEARANCE 34"

CLEARANCE 16"(HORIZONTAL)

CLEARANCE 34"

2" Dia. Hole Power Wires 1.5" Dia. Hole Other Purpose(3EA)

CLEARANCE 46"

Unit: inch(mm) UNITS H I J K L M LK-2080AH/2080CH 25.57(649.5) 15.28(388) 27.34(694.5) 2.40(61) 6.10(155) 57.09(1450)

S U P P L Y
H I

R E T U R N
J

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 22 -

LGE Internal Use Only

7.5~10 Ton Accessories

FRESH AIR HOOD (MANUAL)

Weights
Maximum Unit and Corner Weights (Lbs) and Center of Gravity Dimensions (In.) Tons 5 7.5 10 15 20 Unit Model No. LK-0580HC/BC(S1) LK-0580CC(S)/AC LK-0880HH/BH LK-0880BHS1 LK-0880CH/AH LK-1080HH/BH LK-1080CH/AH LK-1580CH/AH LK-1580HH/BH LK-2080CH/AH Maximum Weights (lbs) Shipping 540 772 970 1,410 2,171
2

Corner Weights (lbs) A 165 209 261 410 639 B 124 161 197 297 438 C 91 116 145 211 320 D 106 132 168 251 411

Center of Gravity (In.) E 28 38 37 40 43 F 19 17 20 28 31

Net 485 617 772 1,168 1,808

Note: 1.Corner weights are given for information only. 2. Weights are approximate.

E A B

D CENTER OF GRAVITY

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 23 -

LGE Internal Use Only

Wiring Diagram
LK-0580HC/BC(S1)
TERMINAL BLOCK

N T S R HUMIDIFIER

3O 4WIRE 380/415V 50Hz POWER SUPPLY

USING ELECTRIC HEATER(OPTION)


FIRE ALARM

EH
BR

TERMINAL REMOVE JUMP WIRE WHEN BLOCK


CONNECTING FIRE ALARM SYSTEM

N T S R

3O 4WIRE 380/415V 50Hz POWER SUPPLY

CANNOT BE USED WHEN USING THERMOSTAT FILLER TERMINAL1 ELECTRO-MECHANICAL THERMOSTAT L


AC 24V FAN
COOLING HEATING COMP.1 HEATER1 HEATER2 EMER.HEATER

WH

3 4
TERMINAL BLOCK2

WH YL BK BK

1 2

WH

FUSE

WH OR BK

(5A 250V)
BK FUSE

(5A 250V)
RD

TRANS
BR YL WH

TERMINAL BLOCK1

WH BK

N T S R

3O 4WIRE 380/ 415V 50Hz POWER SUPPLY

TERMINAL BLOCK
BK BK

N 1 2 3 4 5 6 7

MAGNETIC CONTACT

HEATER Ry Ry TRANS

250V/3.15A
Ry POWER
COMP

POWER RELAY1

HUMID

BL OR 0 1 BL 2 6 4 8

POWER RELAY2

FUSE

OR OR 0 1 2 6 4 8 BK

4-WAY VALVE Ry

Ry

Ry

FAN

Ry

BK OR BL BK WH RD T1 T2 T3 RD RD

CAPACITOR YL BR OR BK

MECHANICAL THERMOSTAT
R X G O B RD WH BK OR BR

CN-THERMOSTAT

AC 24V
FAN COOLING HEATING

INDOOR
AC 13V AC 24V

OUTDOOR

THERMISTOR RETURN AIR (OPTION) THERMISTOR OUT

YL BR

OR BK

COMP

CRANKCASE HEATER

MOTOR OUT

FILLER TERMINAL2
COMP.1 HEATER1 HEATER2 EMER. HEATER Y W W1 E YL BL RD WH BK

MAIN PCB ASM

THERMISTOR IN

TERMINAL BLOCK

CAPACITOR YL BR OR BK

OR

BK(HI) BL(LOW)

FILLER TERMINAL3
CUT AND REMOVE ANTICIPATOR (RESISTOR) CONNECTING WITH CONTACT IN PARALLEL
BR RD YL BR RD YL BK

MOTOR (I N)
YL BR

YL BR

OR BK

CAPACITOR

MOTOR OUT

NOTE
FIELD WIRING FACTORY WIRING

4-WAY VALVE

REMOTE CONTROLLER

FILLER TERMINAL4

REMOVE JUMP WIRE WHEN CONNECTING THERMOSTAT

BK

3854A20033A

BK:BLACK RD:RED BR:BROWN WH:WHITE OR:ORANGE YL:YELLOW BL:BLUE

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 24 -

LGE Internal Use Only

LK-0580AC/CC(S)
TERMINAL BLOCK

N T S R HUMIDIFIER

3O 4WIRE 380/415V 50Hz POWER SUPPLY

USING ELECTRIC HEATER(OPTION)


FIRE ALARM

EH
BR

TERMINAL REMOVE JUMP WIRE WHEN BLOCK


CONNECTING FIRE ALARM SYSTEM

N T S R

3O 4WIRE 380/415V 50Hz POWER SUPPLY

CANNOT BE USED WHEN USING THERMOSTAT FILLER TERMINAL1 ELECTRO-MECHANICAL THERMOSTAT L


AC 24V FAN

WH WH

3 4

BK

YL BK

1 2

WH

FUSE

WH OR BK

(5A 250V)
BK FUSE

(5A 250V)
RD

TRANS
BR YL WH

TERMINAL BLOCK2

TERMINAL BLOCK1

WH BK

N T S R

3O 4WIRE 380/ 415V 50Hz POWER SUPPLY

TERMINAL BLOCK
BK BK

N 1

HEATER1 HEATER2

2 3 4

HEATER Ry Ry TRANS Ry

250V/3.15A
Ry POWER
COMP

POWER RELAY

COMP.1

HUMID

BL OR 0 1 BL 2 6 4 8

FAN

Ry

MAGNETIC CONTACT

FUSE

BK OR BL BK WH RD T1 T2 T3 RD RD

CAPACITOR YL BR OR BK

MECHANICAL THERMOSTAT
R G 1 2 RD WH BK OR BR

CN-THERMOSTAT

AC 24V
FAN

INDOOR
AC 13V AC 24V

THERMISTOR RETURN AIR (OPTION)

YL BR

OR BK

COMP

CRANKCASE HEATER

MOTOR OUT

FILLER TERMINAL2
COMP.1 HEATER1 HEATER2 Y W W1 YL BL RD WH BK

THERMISTOR IN

MAIN PCB ASM

TERMINAL BLOCK

CAPACITOR YL BR OR BK

OR

BK(HI) BL(LOW)

FILLER TERMINAL3
CUT AND REMOVE ANTICIPATOR (RESISTOR) CONNECTING WITH CONTACT IN PARALLEL
BR RD YL BR RD YL

MOTOR (I N)
YL BR

YL BR

OR BK

CAPACITOR

MOTOR OUT

NOTE
FIELD WIRING FACTORY WIRING

LOW PRESSURE SWITCH

REMOTE CONTROLLER

FILLER TERMINAL4

REMOVE JUMP WIRE WHEN CONNECTING THERMOSTAT

3854A20036A

BK:BLACK RD:RED BR:BROWN WH:WHITE OR:ORANGE YL:YELLOW BL:BLUE

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 25 -

LGE Internal Use Only

LK-0880HH/0880BH
WIRING DIAGRAM
N T S R HUMIDIFIER TERMINAL BLCOK 3 4WIRE 380-415V 50Hz POWER SUPPLY
USING ELECRIC HEATER(OPTION)
FIRE ALARM

EH

TERMINAL BLOCK

BR

N T S R

REMOVE JUMP WIRE WHEN CONNECTING FIRE ALARM SYSTEM

EH
BR WH YL BK BK

3 4WIRE 380-415V 50Hz POWER SUPPLY

CANNOT BE USED WHEN USING THERMISTAT

WH

FILLER TERMINAL1 ELECTRO-MECHANICAL THERMOSTAT


L AC 24V FAN COOLING HEATING COMP.1 HEATER1 HEATER2 EMER.HEATER N 1 2 3 4 5 6 7 BR (A) (B) HEATER Ry Ry TRANS Ry Ry FUSE 250V/3.15A Ry POWER 4-WAY VALVE Ry

3 4
TERMINAL BLOCK2

1 2

WH

FUSE

WH BK OR WH

(5A 250V) BK FUSE (5A 250V)

TRANS
BR YL WH

TERMINAL BLOCK1
RD

N T S R
TERMINAL BLOCK

3 4WIRE 380415V 50Hz POWER SUPPLY

BK BK BL BK WH BK

MAGNETIC CONTACT

POWER RELAY1

HUMID

POWER RELAY2

0 1

2 6 4 8

0 1
BL

2 6 4 8

COMP

FAN

Ry

CAPACITOR BK
YL BR OR BK

MECHANICAL THERMOSTAT
AC 24V FAN COOLING HEATING CN-THERMOSTAT OUTDOOR R X G O B RD WH BK OR BR INDOOR AC 13V AC 24V

4-WAY(A) THERMISTOR RETURN AIR (OPTION) THERMISTOR OUT BK WH RD BK WH RD THERMISTOR IN

BK WH RD T1 T2 T3

BK BK

BK BK

BK
YL BR OR BK

COMP

CRANKCASE HEATER

MOTOR OUT
T.P

BK BK

FILLER TERMINAL2
COMP.1 HEATER1 HEATER2 EMER.HEATER Y W W1 E YL BL RD WH BK

MAIN PCB ASM

MOTOR IN
CN18 CN4

FILLER TERMINAL3
CUT AND REMOVE ANTICIPATOR (RESISTOR) CONNECTING WITH CONTACT IN PARALLEL

NOTE FIELD WIRING FACTORY WIRING BK : BLACK RD : RED BR : BROWN WH : WHITE OR : ORANGE YL : YELLOW BL : BLUE

BR RD YL

BR RD YL

BR REMOVE JUMP WIRE WHEN CONNECTING THERMOSTAT 4-WAY VALVE BR

REMOTE CONTROLLER

FILLER TERMINAL4

3854A20027A

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 26 -

LGE Internal Use Only

LK-0880BHS1

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 27 -

LGE Internal Use Only

LK-0880AH/CH
WIRING DIAGRAM
3 4WIRE 380-415V 50Hz POWER SUPPLY HIMIDIFIER TERMINAL BLOCK USING ELECTRIC HEATER(OPTION)
FIRE ALARM

EH

TERMINAL BLOCK

BR

N T S R

REMOVE JUMP WIRE WHEN CONNECTING FIRE ALARM SYSTEM

EH
BR WH WH

3 4WIRE 380-415V 50Hz POWER SUPPLY

CANNOT BE USED WHEN USING THERMOSTAT

FILLER TERMINAL1 TRANS


ELECTRO-MECHANICAL TEHRMOSTAT
BR YL WH

YL BK

1 2
TERMINAL BLOCK1

WH

FUSE
BK RD WH

(5A 250V) BK FUSE (5A 250V)

BK BR BK BK

L N 1 2 3 4

AC 24V FAN COMP.1 Ry Ry HEATER1 HEATER2

TERMINAL BLOCK MAGNETIC CONTACT

N 3 T 4WIRE S 380415V R 50Hz POWER SUPPLY

HEATER TRANS Ry

250V / 3.15A

POWER RELAY1

(A)

(B)

FUSE

HUMID
Ry

BL BK WH

FAN

MECHANICAL THERMOSTAT CN-THERMOSTAT R G


AC 24V FAN RD WH BK OR BR

Ry

COMP

BK

BL INDOOR

BK WH RD T1 T2 T3 THERMISTOR RETURN AIR (OPTION) BK WH RD

BK BK

BK BK

BK WH RD

AC 13V AC 24V

BK WH RD

COMP

CRANKCASE HEATER

MOTOR OUT

2 1 COMP.1 Y W HEATER2 W1
HEATER1

FILLER TERMINAL2
YL BL RD WH BK

MAIN PCB ASM

BK WH RD

THERMISTOR IN

MOTOR IN

FILLER TERMINAL3
CUT AND REMOVE ANTICIPATOR (RESISTOR) CONNECTING WITH CONTACT IN PARALLEL BR RD YL BR RD YL

NOTE
CN18 CN4

LOW PRESSURE SWITCH

FIELD WIRING FACTORY WIRING BK : BLACK RD : RED BR : BROWN WH : WHITE OR : ORANGE YL : YELLOW BL : BLUE

REMOTE CONTROLLER

FILLER TERMINAL4

REMOVE JUMP WIRE WHEN CONNECTING THERMOSTAT

3854A20028A

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 28 -

LGE Internal Use Only

LK-1080HH/1080BH
WIRING DIAGRAM
3 4WIRE 380/415V 50Hz POWER SUPPLY HUMIDIFIER TERMINAL BLOCK FIRE ALARM
CANNOT BE USED WHEN USING THERMOSTAT REMOVE JUMP WIRE WHEN CONNECTING FIRE ALARM SYSTEM TERMINAL BLOCK1 WH WH FUSE WH (5A 250V) YL BK BK FUSE BK (5A 250V)

USING ELECTRIC HEATER(OPTION)

EH

TERMINAL BLOCK

BR

N T S R

EH
BR

3 4WIRE 380/415V 50Hz POWER SUPPLY

ELECTRO-MECHANICAL THERMOSTAT AC 24V FAN COOLING HEATING COMP1 COMP2 HEATER1 HEATER2 EMER. HEATER L N 1 2 3 4 5 6 7 Ry Ry 8 (A) (B) HEATER TRANS
FUSE

WH

FILLER TERMINAL 1
WH

1 2

N T S R
BK WH RD BK BK WH RD

3 4WIRE 380/ 415V 50Hz POWER SUPPLY

TERMINAL BLOCK

TRANS
BR YL

3 4
HUMID YL TERMINAL BLOCK2 BK BK WH

BK BK

250V/3.15A
POWER Ry BK MAGNETIC CONTACT(A) WH BK MAGNETIC CONTACT(B)
POWER RELAY2

CN-THERMOSTAT

Ry

IN

Ry

AC 24V FAN COOLING HEATING

Ry Ry Ry

BK WH RD

FILLER TERMINAL 2
COMP1 Y COMP2 Y1 HEATER1 W2 HEATER2 W1 EMER. E HEATER CUT AND REMOVE ANTICIPATOR (RESISTOR) CONNECTING WIHT CONTACT IN PARALLEL YL BL RD WH BK

AC24V

Ry

R X G O B

RD WH BK OR BR

OUT

COMP(A) COMP

POWER RELAY1

MECHANICAL THERMOSTAT

COMP(B)

Ry

FAN

Ry

8 4 6 2

0 1

1 0 BL

2 6 4 8 BK

BK AC13V

WH

MAIN PCB ASM

BR OR BK

THERMISTOR OUT(A)
BP(A) BP(B) 4-WAY(A) 4-WAY(B)

BK WH RD

BK WH RD T1 T2 T3 COMP(A) BK BK BK BK

BK WH RD
BR OR BK BK BK

THERMISTOR IN(A) THERMISTOR OUT(B)

MOTOR IN

T1 T2 T3 COMP(B) BK BK BK BK

FILLER TERMINAL 3
CN18 REMOVE JUMP WIRE WHEN CONNECTING THERMOSTAT BR RD YL RD RD BK BK RD

T.P

MOTOR OUT

T.P

CN4
SOLENOID VALVE (For B-Cycle) SOLENOID VALVE (For B-Cycle)

THERMISTOR IN(B)

BK BK

CRANKCASE HEATER

BK BK

NOTE

CRANKCASE HEATER

RD
4-way VALVE (For B-Cycle)

BR RD YL REMOTE CONTROLLER

BK
4-way VALVE (For A-Cycle)

FILLER TERMINAL 4

SOLENOID VALVE (For A-Cycle)

BK

3854A20029A

BK : BLACK RD: RED FIELD WIRING BR : BROWN WH : WHITE FACTORY WIRING OR: ORANGE YL : YELLOW BL : BLUE FOR BYPASS BETWEEN D-PIPE ~ COND MIDDLE FOR BYPASS BETWEEN D-PIPE ~ S-PIPE

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 29 -

LGE Internal Use Only

BK BK

THERMISTOR RETURN AIR (OPTION)

CAPACITOR

LK-1080AH/CH
WIRING DIAGRAM
3 4WIRE 380/415V 50Hz POWER SUPPLY HUMIDIFIER TERMINAL BLOCK FIRE ALARM
CANNOT BE USED WHEN USING THERMOSTAT REMOVE JUMP WIRE WHEN CONNECTING FIRE ALARM SYSTEM

USING ELECTRIC HEATER(OPTION)

EH

TERMINAL BLOCK

BR

N T S R

EH
BR

3 4WIRE 380/415V 50Hz POWER SUPPLY

ELECTRO-MECHANICAL THERMOSTAT AC 24V FAN L N 1

WH

FILLER TERMINAL 1
WH

TERMINAL BLOCK1 WH WH FUSE WH (5A 250V) YL BKFUSE BK BK (5A 250V)

1 2

N T S R
BK WH RD BK BK WH RD

3 4WIRE 380/ 415V 50Hz POWER SUPPLY

TERMINAL BLOCK

TRANS
BR COMP1 COMP2 HEATER1 HEATER2 2 3 4 5 Ry Ry (A) (B) HEATER TRANS FUSE HUMID YL YL

3 4
TERMINAL BLOCK2

BK BK

250V/3.15A
POWER Ry BK BK WH BK MAGNETIC CONTACT(A) WH BK MAGNETIC CONTACT(B)
POWER RELAY2 COMP(B)

Ry

POWER RELAY1

CN-THERMOSTAT

MECHANICAL THERMOSTAT AC 24V FAN


R G 1 2

FAN IN

Ry

RD WH BK OR BR

Ry

Ry

OUT

COMP(A) COMP

8 4 6 2

0 1

1 0 BL

2 6 4 8 BK

BK AC13V AC24V

WH

CUT AND REMOVE ANTICIPATOR (RESISTOR) CONNECTING WIHT CONTACT IN PARALLEL

FILLER TERMINAL 3
CN18 REMOVE JUMP WIRE WHEN CONNECTING THERMOSTAT BK BK WH WH BR RD YL
LOW PRESSURE SWITCH(A-Cycle) LOW PRESSURE SWITCH(B-Cycle)

THERMISTOR IN(A)

MOTOR IN T.P

YL BR OR BK MOTOR OUT T.P BK BK BK BK

T1 T2 T3 COMP(A) BK BK BK BK

T1 T2 T3 COMP(B)

CN4

THERMISTOR IN(B)

BK BK

CRANKCASE HEATER

BK BK

NOTE FIELD WIRING

BR RD YL REMOTE CONTROLLER

CRANKCASE HEATER

FILLER TERMINAL 4

3854A20030A

BK : BLACK RD: RED BR : BROWN WH : WHITE FACTORY WIRING OR: ORANGE YL : YELLOW BL : BLUE

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 30 -

LGE Internal Use Only

BK BK

COMP1 Y COMP2 Y1 HEATER1 W2 HEATER2 W1

YL BL RD WH BK

YL BR OR BK BK WH RD BK WH RD BK WH RD

BK BK

THERMISTOR RETURN AIR (OPTION)

BK WH RD

FILLER TERMINAL 2

MAIN PCB ASM


CAPACITOR

LK-1580HH/1580BH
WIRING DIAGRAM
N T S R HUMIDIFIER TERMINAL BLOCK 3 4WIRE 380/415V 50Hz POWER SUPPLY
USING ELECTRIC HEATER(OPTION) TERMINAL BLOCK

EH

N T S R EH

FIRE ALARM

3 4WIRE 380/415V 50Hz POWER SUPPLY

CANNOT BE USED WHEN USING THERMOSTAT

REMOVE JUMP WIRE WHEN CONNECTING FIRE ALARM SYSTEM

TERMINAL BLOCK1
WH WH YL BK

ELECTRO-MECHANICAL THERMOSTAT AC 24V FAN COOLING HEATING COMP1 COMP2 HEATER1 HEATER2 EMER. HEATER L N 1 2 3 4 5 6
Ry

WH TRANS YL FUSE

BK 8 4 0 1

3 4
HUMID

6 2

(A)

(B)
HEATER Ry TRANS

YL BR OR BK

7 8

POWER Ry

WH BK BK MAGNETIC CONTACT(A) BK MAGNETIC CONTACT(B)

YL BR OR BK

Ry

Ry

Ry

BR AC13V
Ry Ry

BK WH BK WH RD 6 2 8 4
CAPACITOR

FILLER TERMINAL 2
COMP1 COMP2 HEATER1 HEATER2 EMER. HEATER Y Y1 W2 W1 E YL BL RD WH BK

0 1

AC24V MAIN PCB ASM

THERMISTOR RETURN AIR (OPTION)

THERMISTOR OUT AIR THERMISTOR OUT(A)

BK WH RD

YL BR OR BK

MOTOR IN
T.P

BR RD YL REMOTE CONTROLLER

BR RD YL

4-WAY VALVE (For A-Cycle)

RD
4-WAY VALVE (For B-Cycle)

BK BK

CUT AND REMOVE ANTICIPATOR (RESISTOR) CONNECTING WITH CONTACT IN PARALLEL

REMOVE JUMP WIRE WHEN CONNECTING THERMOSTAT

BK

RD

CN
THERMISTOR IN(B)

BK BK

CN

4WAY(B)

4WAY(A)

COMP(A)

COMP(B)

BK

BK

MOTOR OUT(A) T.P

NOTE

CRANKCASE HEATER(A)

CRANKCASE HEATER(B)

FILLER TERMINAL 4

BK

SOLENOID VALVE (For A-Cycle)

BK

3854A20011D

BK:BLACK RD:RED BR:BROWN WH:WHITE OR:ORANGE YL:YELLOW FACTORY WIRING BL:BLUE FIELD WIRING

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 31 -

LGE Internal Use Only

BK BK

FILLER TERMINAL 3

BY PASS(A)

THERMISTOR IN(A) THERMISTOR OUT(B)

T1 T2 T3 BK

BK T1 T2 T3 YL BR OR BK

BK BK

BK WH RD

BK WH RD

POWER RELAY2

FAN COOLING HEATING

R X G O B

CN-THERMOSTAT

Ry

IN

Ry

AC 24V

RD WH BK OR BR

OUT(B)

OUT(A)

COMP(A)

BK

POWER RELAY1

MECHANICAL THERMOSTAT

COMP(B)

FAN

COMP

1 0

MOTOR OUT(B) T.P

BK WH

2 6 4 8

BK BK BR

BK BK

250V/3.15A

TERMINAL BLOCK2

CAPACITOR

POWER RELAY3

FILLER TERMINAL 1

1 2

WH

FUSE WH

(5A 250V)
BK FUSE BK

N T S R
BK WH RD BK BK WH RD

3 4WIRE 380/ 415V 50Hz POWER SUPPLY


BR

(5A 250V)
BK

TERMINAL BLOCK

LK-1580AH/CH
WIRING DIAGRAM
N T S R TERMINAL BLOCK 3 4WIRE 380/415V 50Hz POWER SUPPLY
USING ELECTRIC HEATER(OPTION)

EH

TERMINAL BLOCK

N T S R EH

HUMIDIFIER

FIRE ALARM

3 4WIRE 380/415V 50Hz POWER SUPPLY

CANNOT BE USED WHEN USING THERMOSTAT

REMOVE JUMP WIRE WHEN CONNECTING FIRE ALARM SYSTEM

TERMINAL BLOCK1
WH WH YL BK

ELECTRO-MECHANICAL THERMOSTAT AC 24V FAN L N 1 TRANS YL COMP1 COMP2 HEATER1 HEATER2 2 3 4


Ry

FILLER TERMINAL 1
WH

1 2

WH

FUSE WH

(5A 250V)
BK FUSE BK

N T S R
BK WH RD BK WH RD

3 4WIRE 380/ 415V 50Hz POWER SUPPLY


POWER RELAY3 POWER RELAY2

(5A 250V)
BK

TERMINAL BLOCK
BK 6 2 BR 0 1 BR RD WH

3 4
HUMID

8 4

(A)

(B)
HEATER Ry TRANS

FUSE

WH WH

POWER Ry

WH RD BK BK MAGNETIC CONTACT(A) BK MAGNETIC CONTACT(B)

Ry

Ry

CN-THERMOSTAT

Ry

IN

Ry

AC 24V FAN

R G 1 2

RD WH BK OR BR

OUT(B)

OUT(A)

COMP(A)

COMP

BK

POWER RELAY1

MECHANICAL THERMOSTAT

Ry

COMP(B)

1 0

BK WH

FAN

MOTOR OUT(B)

2 6 4 8

BK

BK

250V/3.15A

TERMINAL BLOCK2

BR WH BK 6 2 8 4 0 1 BR

BR WH BK WH RD BK WH RD

FILLER TERMINAL 2
COMP1 COMP2 HEATER1 HEATER2 Y Y1 W2 W1 YL BL RD WH BK

AC13V AC24V MAIN PCB ASM


THERMISTOR RETURN AIR (OPTION)

THERMISTOR OUT AIR

WH WH

RD

BR RD YL REMOTE CONTROLLER

BR RD YL

BK

BK WH

WH

BK BK

CUT AND REMOVE ANTICIPATOR (RESISTOR) CONNECTING WITH CONTACT IN PARALLEL

REMOVE JUMP WIRE WHEN CONNECTING THERMOSTAT

BK BK

CN CN
THERMISTOR IN(B)

COMP(A)

COMP(B)

BK

BK

MOTOR OUT(A)

NOTE

CRANKCASE HEATER(A)

CRANKCASE HEATER(B)

LOW PRESSURE SWITCH(A-Cycle)

LOW PRESSURE SWITCH(B-Cycle)

FILLER TERMINAL 4

3854A20011C

BK:BLACK RD:RED BR:BROWN WH:WHITE FACTORY WIRING OR:ORANGE YL:YELLOW BL:BLUE FIELD WIRING

LK-1580AHS1

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 32 -

BK

FILLER TERMINAL 3

THERMISTOR IN(A)

MOTOR IN
T.P

T1 T2 T3 BK

T2 T3 BK T1

BK

BK WH RD

BK WH RD

RD

LGE Internal Use Only

LK-2080AH/CH
WIRING DIAGRAM
3 4WIRE 380/415V 50Hz POWER SUPPLY
USING ELECTRIC HEATER(OPTION)

EH

TERMINAL BLOCK

HUMIDIFIER

TERMINAL BLOCK

FIRE ALARM

EH

3 4WIRE 380/415V 50Hz R POWER SUPPLY N T S

CANNOT BE USED WHEN USING THERMOSTAT ELECTRO- MECHNICAL THERMOSTAT AC 24V FAN
L N

REMOVE JUMP WIRE WHEN CONNECTING FIRE ALARM SYSTEM


TERMINAL BLOCK1
WH WH BK

BK

YL BK

FILLER TERMINAL 1
WH

1 2

WH

FUSE WH

N T S R

(5A 250V)
BK FUSE BK

3 4WIRE 380/ 415V 50Hz POWER SUPPLY


BR 6 2 0 1
POWER RELAY3 POWER RELAY2

(5A 250V)
BK

BK WH RD

BK WH RD

TERMINAL BLOCK
BK

TRANS
YL

COMP1 COMP2 HEATER1 HEATER2

2 3 4
Ry

3 4
HUMID

8 4

(A)

(B)
HEATER Ry TRANS

FUSE

Ry

MAGNETIC CONTACT(A)

MAGNETIC CONTACT(B)

Ry

Ry

FAN

G 1 2

WH BK OR BR

IN

Ry

AC 24V

CN-THERMOSTAT

RD

OUT(B)

OUT(A)

COMP(A) COMP

BK

POWER RELAY1

MECHANICAL THERMOSTAT

Ry

COMP(B) FAN

BK WH

MOTOR OUT(B)
T.P

1 0 BR

2 6 4 8

BK

AC13V

BK WH RD

FILLER TERMINAL 2 COMP1 Y COMP2 Y1 HEATER1 W2 HEATER2 W1


YL BR RD WH BK

WH
THERMISTOR RETURN AIR (OPTION)

6 2 8 4

AC24V

MAIN PCB ASM

BK WH RD

THERMISTOR OUT AIR

CAPACITOR YL BR OR BK BK WH RD T1 T2 T3 BK COMP(A) BK WH RD BK T1 T2 T3 YL BR OR BK COMP(B) BK BK BK BK BK BK

MOTOR IN
THERMISTOR IN(A) T.P

CUT AND REMOVE ANTICIPATOR (RESISTOR) CONNECTING WITH CONTACT IN PARALLEL BR RD YL

FILLER TERMINAL 3
REMOVE JUMP WIRE WHEN CONNECTING THERMOSTAT

CN
THERMISTOR IN(B)

BK BK

CN

MOTOR OUT(A)
T.P

BR RD YL

BK

BK

WH

WH

BK BK

NOTE

CRANKCASE HEATER(A)

CRANKCASE HEATER(B)

LOW PRESSURE SWITCH(A-Cycle)

LOW PRESSURE SWITCH(B-Cycle)

REMOTE CONTROLLER FILLER TERMINAL 4

3854A20052A

BK:BLACK RD:RED BR:BROWN WH:WHITE FACTORY WIRING OR:ORANGE YL:YELLOW BL:BLUE FIELD WIRING

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 33 -

LGE Internal Use Only

BK BK BR 0 1

BK

BK

BK

YL BR OR BK

POWER

WH

BK BK

250V/3.15A

YL BR OR BK

TERMINAL BLOCK2

CAPACITOR

Troubleshooting Guide
PACKAGE AIR CONDITIONER VOLTAGE LIMITS
NAME PLATE RATING 380 - 415V MINIMUM 342V MAXIMUM 456V

1. No cooling and heating operation performed


1) Both the blower and the compressor do not work
WHAT TROUBLED Other parts except the unit COMPLAINTS Electric supply interrupted Defective power wiring Cut off power fuse HOW TO CHECK Measure power sypply with a tester in case that the same power source is supplied to other equipment except the unit, what and where troubled can be discovered by checking the operation of other equipment. Measure it with a tester. REMEDY Repair a switch box and relative instrument. Replacement of fuse Request a power supplier to repair.

Too low voltage

Check the power source. Use a thick cable if necessary. Replace it if necessary.

Magnetic switch for compressor & fan motor

Control point is on condition of "OFF" due to trouble. Troubled or defective contactor

Make short-circuit, then measure it with tester.

Operating switch

Check it with the eyes or tester.

Repair or replace it.

2) Only Indoor blowers do not work


WHAT TROUBLED Motor COMPLAINTS Over heated Wiring short Cut- OFF of wiring Short circuited on operation HOW TO CHECK Check it with tester REMEDY Repair or replace it.

Electric wiring

Check it with a tester.

Rewiring or Repair.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 34 -

LGE Internal Use Only

3) Only outdoor fan does not work


WHAT TROUBLED Motor Electric Wiring COMPLAINTS Over-heated Wire short Cut off of wiring Short circuited on operation Capacitor Defected Check it with tester. Replace it. HOW TO CHECK Check how it is insulated. Check it with a tester. REMEDY Repair or replace it. Rewiring or repair.

4) Only compressor does not work


WHAT TROUBLED Magnetic switch for compressor motor Compressor motor COMPLAINTS Defective contact, magnetic coil troubled. Troubled over-heated (layer short) Troubled or defective contact or operating Defective connection or disconnection of the circuit for compressor. HOW TO CHECK Check it with the eyes on with a tester. Check how it is insulated. REMEDY Repair or replace it.

Replace or repair the compressor. Replace it if necessary. Rewiring or push reset button.

High pressure switch (Option part) Electric circuit

Check it with a tester.

Check it with a tester.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 35 -

LGE Internal Use Only

2. The Units discontinue after the operation started


WHAT TROUBLED Outdoor coil COMPLAINTS Coil is dirty *1 HOW TO CHECK Checking REMEDY Wash it by means of something like chemical washing. Extract air by vacuum pump, then replenish (charge) the refrigerant.

In-condensable gas blended.

Air intruded into the refrigerant pipe line *1

In the event that difference between the saturating temperature corresponding to high pressure and the temperature of air discharged from the outdoor coil is more than 15C, incondensable gas may be blended. Check it with a pressure gauge.

High pressure switch (Option part)

Improper adjustment

Read just it to normal operating pressure. (Note) Don't alternate the specified adjusting pressure. If the adjusted pressure exceed the specified range, it will cause a great accident. Replenish the refrigerant. Repair the spot where it is leaked. If reversed, connect interchanged wires to each terminal. Power wirings.

Refrigerant

A shortage of refrigerant amount. * 2

Check pressure

Outdoor Fan

Reverse rotation of fan Obstacle Air short circuit *1

Confirm the wind blowing out upward. Check it with eyes.

Note: Use an appropriate measuring instrument for readjustment. *1: High-pressure switch moves. *2: Low- pressure switch moves.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 36 -

LGE Internal Use Only

3. The unit is working, but not cooling and heating sufficiently (Both blower and compressor are working)
WHAT TROUBLED Load COMPLAINTS Much Cooling or Heating load HOW TO CHECK Heat load increased. Window or door has many cracks or gaps. Checking REMEDY Do necessary disposal respectively.

Air flow

Obstacle disturbs Intake of uniform airflow. Reverse rotation of blower. Shortage in the charged refrigerant. Improper or foreign bodies

Correct it.

Short air volume

Checking

Correct it.

Refrigerant

Coil inlet pipe is frosted

Recharge it. (Repair the leakage spot). Correct or clear the foreign bodies. Cleaning

Air passage

Checking Checking

Air filter

Clogged with dust

4. All the functions are performed as specified, but very noisy and vibrant
WHAT TROUBLED Compressor COMPLAINTS Liquid refrigerant flooding back from the evaporator. HOW TO CHECK REMEDY

Check for refrigerant over-charge. Check to see if the intake air temperature is extremely cold. Check for insufficient air flow quantity. Checking Replace the compressor Repair or replace it. Clear the foreign bodies.

Faulty Discharge valve and suction valve. Blower Fan broken. Foreign matters intruded. Screws Electric troubles (Magnetic contactor) Looseness or fail-off of screws Defective contact. Defective contact point. Rusting and foreign matters in the iron core contact face. Defective contact of the operating switch. Improper installation

Checking

Checking

Correct Repair and clean or replace it.

Checking

Others

Checking

Correct it.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 37 -

LGE Internal Use Only

Electronic parts Troubleshooting Guide


Possible trouble 1
Is the input voltage of transformer AC220V?
YES

: The unit does not operate.


NO

1. Check the Fuse. 2. Check the wiring of AC220V.

Is the output voltage of transformer AC24V & AC13V?


YES

NO

1. Exchange the transformer. 2. Check the connector of transformer.

Is the output voltage of IC01D(7812 ) on the main PCB DC12V?


YES

NO

1. Exchange IC01D(7812) on the main PCB. 2. Check the D01D~D05D, R05C on the main PCB. 1. Exchange IC02D(7805) on the main PCB. 2. Check the D01D~D05D, R05C on the main PCB.

Is the output voltage of IC02D(7805) on the main PCB DC5V?


YES

NO

Is the output voltage of IC01A(7036) on the main PCB DC5V?


YES

NO

1. Exchange IC01A(7036) on the main PCB.

OSC01B vibration?

NO

1. Exchange OSC01B. 2. Check the pattern around OSC01B on the main PCB.

YES

1. Exchange main PCB ASS'Y

Possible trouble 2

: The remote-controller does not operate.


NO

Is the power ON?


YES

1. Check the FUSE. 2. Check the input voltage of Main PCB ASS'Y.

Is the input voltage of remote-controller DC12V?


YES

NO

1. Check or exchange the IC01D on the Main PCB. 2. Check or exchange the Connector (RED, BROWN) of the remote controller.

1. Exchange remote-controller 2. Check or exchange the Main PCB ASS'Y.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 38 -

LGE Internal Use Only

Possible trouble 3
Is the connection between MAIN PCB and remote-controller correct?
YES

: Key input of remote-controller does not respond.


NO

1. Check or repair Connector wiring. 2. Exchange the Connector.

Is any key on the remote-controller keeping pressed?


NO

YES

1. Replace the pressed key. 2. Exchange the Knob or Key.

Is there Check(F**) on the remote controller LCD?


NO

YES

1. Remove cause of Check. 2. Reenergize the power supply.

Is the input power voltage of remote-controller DC12V?


YES

NO

1. Check or exchange IC01D (7812) on the MAIN PCB.

Is there OSC01B vibration on the remote-controller PCB?


YES

NO

1. Exchange OSC01B 2. Check the pattern around OSC01B on the remote-controller PCB.

Do Keys have troubles?

YES

1. Check Keys. 2. Repair or exchange Key.

NO

Exchange remote-controller.

Possible trouble 4
Are there trouble in LCD parts?
NO

: LCD display on the remote-controller shows some trouble.


YES

1. Check crack, damage of LCD. 2. Check LCD pattern.

Is there trouble in the remote-controller PCB ASS'Y?


NO

YES

1. Check or repair all IC with dust or moisture on the PCB. 2. Exchange remote-controller PCB.

Exchange remote-controller.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 39 -

LGE Internal Use Only

Possible trouble 5
Is the unit operating?

: No cooling operation performed.


NO

1. Press power ON/OFF button.

YES

Is the cooling mode?

NO

1. Press cooling operation key. 2. After reenergizing power supply, press power "ON/OFF" button.

YES

Set Temp. < Room Temp.?

NO

1. Set following. 'Set Temp. < Room Temp.'

YES

Is the output voltage of IC02D on the MAIN PCB DC5V?


YES

NO

1. Check or exchange IC01D, IC02D on the MAIN PCB.

Is the output voltage of IC01M's 13/12(COMP B)PIN on the MAIN PCB DC0V?
YES

NO

1. Check or exchange IC01M. 2. Check 3-minutes time delay.

Is the voltage between A/B(COMP B) of CN-COMP and NEUTRAL 220V?


YES

NO

1. Check or exchange RY4/RY5(COMP B).

Is the magnetic contactor for compressor ON?


YES

NO

1. Check the wiring of Magnetic contactor. 2. Exchange Magnetic contactor.

1. Check Compressor and Capacitor for Compressor. NOTE: 3 model has not capacitor for compressor.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 40 -

LGE Internal Use Only

Possible trouble 6

: No heater operation performed.


NO

Is the heater operation?

1. Select heater operation mode.

YES

Is the heater LCD "ON"?

NO

1. Reconnecting power supply. Press Heater Key.

YES

Set temp. > Room temp.?

NO

1. Set following. 'Set temp. > Room temp.'

YES

Is the output voltage of IC02D on the MAIN PCB DC5V?


YES

NO

1. Check or exchange IC01D, IC02D on the MAIN PCB.

Is the output voltage of IC02M's 11PIN on the MAIN PCB 0V?


YES

NO

1. Check or exchange IC02M.

Is the voltage between A/B(Heat B) of CN-HEAT(CN6) and NEUTRAL 220V?


YES

NO

1. Check or exchange RY13/RY14(Heat B).

Is the magnetic contactor for heater ON?


YES

NO

1. Check the wiring of Magnetic contactor. 2. Exchange Magnetic contactor.

Check or exchange E/Heater.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 41 -

LGE Internal Use Only

Possible trouble 7

: No humidifier operation performed.


NO

Is the indoor fan operation?

1. Press cooling or fan operation or heater operation key.

YES

Is the HUMID LCD "ON"?

NO

1. Press humidifier Key.

YES

Is the output voltage of IC02D on the MAIN PCB DC5V?


YES

NO

1. Check or exchange IC01D. IC02D on the MAIN PCB.

Is the output voltage of IC02M's 12PIN on the MAIN PCB 0V?


YES

NO

1. Check or exchange IC02M.

Is the voltage between 1PIN of CN-HUMID and NEUTRAL 220V?


YES

NO

1. Check or exchange RY3.

Is the magnetic contactor for humidifier ON?

NO

1. Check the wiring or Magnetic contactor. 2. Exchange Magnetic contactor.

YES

Check the humidifier.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 42 -

LGE Internal Use Only

Possible trouble 8
Is the unit operating?

: Indoor motor does not operate.


NO

1. Press power ON/OFF button. 2. Reconnect the power supply.

YES

Is the output voltage of IC02M's 14PIN on the MAIN PCB 0V?


YES

NO

1. Check or exchange IC01M.

Is the voltage between 1PIN(IN) of CN-FAN(IN) and NEUTRAL 220V?


YES

NO

1. Check or exchange RY10.

Is the "Power relay" for indoor motor ON?


YES

NO

1. Check the wiring of "Power relay". 2. Exchange "Power relay".

Check the indoor motor.

Possible trouble 9
Is it cooling operation?

: Outdoor motor does not operate.


NO

1. Press power "ON/OFF" button. 2. Select cooling operation.

YES

Is the compressor operating?

NO

YES

1. Set following. Set temp. < Room temp. 2. Wait, if the unit has operating with 3-minute time delay.

Is the output voltage of IC02M's 13/12(OUT FAN B) on the MAIN PCB 0V?
YES

NO

1. Check or exchange IC02M.

Is the voltage between OUT A/B of CN-FAN and NEUTRAL 220V?


YES

NO

1. Check or exchange RY11/RY12(OUT FAN B).

Is the "Power relay" for outdoor motor ON?


YES

NO

1. Check the wiring of "Power relay". 2. Exchange "Power relay".

Check the outdoor motor A/B.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 43 -

LGE Internal Use Only

Possible trouble 10
Is the unit operating?

: No heating operation performed.


NO

1. Press power ON/OFF button.

YES

Is the heating mode?

NO

1. Press heating operation key. 2. After reenergizing power supply, press power "ON/OFF" button.

YES

Set Temp. > Room Temp.?

NO

1. Set following. 'Set Temp. > Room Temp.'

YES

Is the output voltage of IC02D on the MAIN PCB DC5V?


YES

NO

1. Check or exchange IC01D, IC02D on the MAIN PCB.

Is the output voltage of IC02M's 16/15(4WAY B) on the MAIN PCB DC0V?


YES

NO

1. Check or exchange IC02M.

Is the voltage between 4WAY A/B of CN-BYPASS and NEUTRAL 220V?


YES

NO

1. Check or exchange RY8/9(4WAY B).

1. Check 4WAY A and B.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 44 -

LGE Internal Use Only

Possible trouble 11

: No heater operation performed.


NO

Is the heater operation?

1. Select heater operation mode.

YES

Is the heater LCD "ON"?

NO

1. Reconnecting power supply. Press Heater Key.

YES

Set temp. > Room temp.?

NO

1. Set following. 'Set temp. > Room temp.'

YES

Is the output voltage of IC02D on the MAIN PCB DC5V?


YES

NO

1. Check or exchange IC01D, IC02D on the MAIN PCB.

Is the output voltage of IC01M's 16PIN on the MAIN PCB 0V?


YES

NO

1. Check or exchange IC01M.

Is the voltage between 1PIN of CN5 and NEUTRAL 220V?


YES

NO

1. Check or exchange RY1.

Is the magnetic contactor for heater OK?


YES

NO

1. Check the wiring of Magnetic contactor. 2. Exchange Magnetic contactor.

Check or exchange E/Heater.

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 45 -

LGE Internal Use Only

Features of Controller
1. Main Controller Circuit Diagram

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 46 -

LGE Internal Use Only

2. Feature of Main Controller

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 47 -

LGE Internal Use Only

3. Feature of Remote-Controller PCB ASS'Y

4. Feature of Remote-Controller LCD

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 48 -

LGE Internal Use Only

5. Error Mode & Corrective Method


Error mode F01 Cause of error Sensing condition of error Method of SVC Remark OPEN/SHORT of Voltage of sensing: Over 4.8V room temp. Voltage of sensing: Less than sensor 0.5V OPEN/SHORT of Voltage of sensing: Over 4.8V indoor pipe temp. Voltage of sensing: Less than 0.5V sensor Communication Error F03 Communication interruption between remote controller and Main PCB for 2 minutes. Room 1. Check the voltage of "CO1H" temp.(25C) on the remote controller. = DC 2.5V 2. Check the temp. sensor of remtote controller. 1. Check the voltage between PIN 3 Pipe temp.(25C) and 4 of CN-A cycle/CN-B cycle. = DC 2.2V 2. Check the temp. sensor of indoor pipe. 1. Check the connecting wire between main PCB remote controller. 2. Check the input voltage of remote-controller. 3. Check the wiring of remote-controller. 1. Check the voltage between PIN 1 and 2 of CN-A cycle/CN-B cycle ON the main PCB. 2. Check the temp. sensor of remtote controller. 1. Check the voltage between PIN 1 and 3 of CN-TEMP OUT on the main PCB. 2. Check the temp. sensor of outdoor room. Input voltage of remote-controller = DC 12V

F02

F04

OPEN/SHORT of Voltage of sensing: Over 4.8V Voltage of sensing: Less than outdoor pipe 0.5V sensor OPEN/SHORT of Voltage of sensing: Over 4.8V Voltage of sensing: Less than outdoor room 0.5V temp. sensor

Pipe temp.(25C) = DC 2.5V

F05

Room temp.(25C) = DC 2.2V

6. Principal part list of controller


Model LK-0580CH/AH LK-0880CH/AH LK-1080CH/AH LK-1580CH/AH LK-2080CH/AH LK-0580HH LK-0880HH/BH LK-0880BHS1 LK-1080HH/BH LK-1580HH/BH Main PCB ASM 6871A20085B 6871A20085D 6711A20007B 6323AQ2333T 6871A20085E 6871A20085A 6711A20007C 6323AQ2333W 6871A20085C 6871A20085F 6323AQ2333X 6323AQ2333U 6323AQ3214M (OPTION) 6323AQ3214H Remote controller Pipe Sensor A Outdoor Pipe Return Air Room Sensor Sensor A/B Sensor Power Trans 6171AQ2138E Remark

6171AQ2138D Cooling Only 6171AQ2138E 6171AQ2138E 6171AQ2138D 6323AQ3214H Heat Pump

6323AQ3214M (OPTION)

7. Principal part list of Main PCB ASM


No 1 2 3 4 5 Part No 0ITO874000E 6920AQ9033F 6212AQ9002J 6900AQ9028D 6102A90001A Part Name MICOM(Main) Relay Oscillator Fuse Varistor Remarks MICOM

8. Principal part list of Remote Controller


No 1 2 3 4 Part No OITO641010B 6304A30001C 6871A20043A 6871A20043H Part Name Remark MICOM(Remote Controller) MICOM LCD Remote C PCB ASM Cooling Only Remote C PCB ASM Heat Pump

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 49 -

LGE Internal Use Only

9. Explanation of principal function


I Flow Chart
START(Power supply)
YES

1. Initialize "micom". 2. A/D convert. 3. Main PCB: Waiting cooling operation. 4. Remote controller: Waiting input. Dehumidification Mode?
A YES YES

NO

Heater operation mode?

YES

Power ON?

NO

Dehumidification operating
YES NO

NO

Set Temp. > Indoor Temp.

YES

Cooling Mode?

Stop condition? Heater operating

YES

YES

YES

NO

Go to A Set Temp. < Indoor Temp.

NO

Stop condition?

YES YES

YES

Go to A

Time delay mode

NO

Cooling operating

Fan only operating

NO

Stop condition?

NO

Stop condition?

YES

YES

Go to A

Go to A

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 50 -

LGE Internal Use Only

Exploded View
1. LK-0580AC
Exploded View
336610 359012 435301

346810 354210A

349610

349480 559010

354210B 552111

546810 549610

330871

554031

249950

W6920

W0CZZ 268711B 566001 554160

566000A

W6631 Comp. wire 566000B

websit e-mail e http://w http://w ww.LG ww.LG Eservic Eservic e.com e.com/ techsup .html

267110

Model LK-0580AC/0580CC(S)/0580HC/0580BC(S1)

Classication -

Description Compressor Harness,Multi

Part Number 5417A20008G 6863A20007B

Location Number Remark 554160 W6631 LGE Internal Use Only

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 51 -

2. LK-0580BC
Exploded View
336610 359012 435301

346810 354210A

349610

349480 559010

354210B 552111

546810 549610

330871

554031

249950

W6920

W0CZZ 268711B 566001 554160

W6631 Comp. wire

websit e-mail e http://w http://w ww.LG ww.LG Eservic Eservic e.com e.com/ techsup .html

267110

Model LK-0580AC/0580CC(S)/0580HC/0580BC(S1)

Classication -

Description Compressor Harness,Multi

Part Number 5417A20008G 6863A20007B

Location Number Remark 554160 W6631 LGE Internal Use Only

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 52 -

3. LK-0580BCS1
Exploded View
336610 359012 435301

346810 354210A

349610

349480 559010

354210B 552111

546810 549610

330871

554031

249950

W6920

W0CZZ 268711B 566001 554160

W6631 Comp. wire 566000B

websit e-mail e http://w http://w ww.LG ww.LG Eservic Eservic e.com e.com/ techsup .html

267110

Model LK-0580AC/0580CC(S)/0580HC/0580BC(S1)

Classication -

Description Compressor Harness,Multi

Part Number 5417A20008G 6863A20007B

Location Number Remark 554160 W6631 LGE Internal Use Only

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 53 -

4. LK-0580CC
Exploded View
336610 359012 435301

346810 354210A

349610

349480 559010

354210B 552111

546810 549610

330871

554031

249950

W6920

W0CZZ 268711B 566001 554160

566000A

W6631 Comp. wire

websit e-mail e http://w http://w ww.LG ww.LG Eservic Eservic e.com e.com/ techsup .html

267110

Model LK-0580AC/0580CC(S)/0580HC/0580BC(S1)

Classication -

Description Compressor Harness,Multi

Part Number 5417A20008G 6863A20007B

Location Number Remark 554160 W6631 LGE Internal Use Only

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 54 -

5. LK-0580HC
Exploded View
336610 359012 435301

346810 354210A

349610

349480 559010

354210B 552111

546810 549610

330871

554031

249950 567480

W6920

W0CZZ 268711B 566001 554160

W6631 Comp. wire

websit e-mail e http://w http://w ww.LG ww.LG Eservic Eservic e.com e.com/ techsup .html

267110

Model LK-0580AC/0580CC(S)/0580HC/0580BC(S1)

Classication -

Description Compressor Harness,Multi

Part Number 5417A20008G 6863A20007B

Location Number Remark 554160 W6631 LGE Internal Use Only

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 55 -

6. LK-0880AH
Exploded View
435311 W4811

346810 336610

249950 359001 145610B 349490 W6920

349480

342800 W4400 152302A 152302B 145610A

559010

268711B

566001

546810 549610

W6631 Comp. wire


566000A 554031 552111 567480 566000B 330871 554160

websit e-mail e http://w http://w ww.LG ww.LG Eservi Eservi ce.com ce.com /techsu p.html

267110

Model LK-0880AH/LK-0880BH(S1)/LK-0880CH/LK-0880HH

Classication -

Description Compressor Harness,Multi

Part Number 5417A20007F 6863A20001X

Location Number Remark 554160 W6631 LGE Internal Use Only

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 56 -

7. LK-0880BH/LK-0880HH
Exploded View
435311 W4811

346810 336610

249950 359001 145610B 349490 W6920

349480

342800 W4400 152302A 152302B 145610A

559010 W0CZZ 268711B 566001 546810 549610

W6631 Comp. wire


554031 552111 567480 554160

330871

websit e-mail e http://w http://w ww.LG ww.LG Eservi Eservi ce.com ce.com /techsu p.html

267110

Model LK-0880AH/LK-0880BH(S1)/LK-0880CH/LK-0880HH

Classication -

Description Compressor Harness,Multi

Part Number 5417A20007F 6863A20001X

Location Number Remark 554160 W6631 LGE Internal Use Only

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 57 -

8. LK-0880BHS1
Exploded View
435311 W4811

346810 336610

249950 359001 145610B 349490 W6920

349480

342800 W4400 152302A 152302B 145610A

559010 W0CZZ 268711B 566001 546810 549610

W6631 Comp. wire


554031 552111 567480 566000B 330871 554160

websit e-mail e http://w http://w ww.LG ww.LG Eservi Eservi ce.com ce.com /techsu p.html

267110

Model LK-0880AH/LK-0880BH(S1)/LK-0880CH/LK-0880HH

Classication -

Description Compressor Harness,Multi

Part Number 5417A20007F 6863A20001X

Location Number Remark 554160 W6631 LGE Internal Use Only

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 58 -

9. LK-0880CH
Exploded View
435311 W4811

346810 336610

249950 359001 145610B 349490 W6920

349480

342800 W4400 152302A 152302B 145610A

559010

268711B

566001

546810 549610

W6631 Comp. wire


566000A 554031 552111 567480 554160

330871

websit e-mail e http://w http://w ww.LG ww.LG Eservi Eservi ce.com ce.com /techsu p.html

267110

Model LK-0880AH/LK-0880BH(S1)/LK-0880CH/LK-0880HH

Classication -

Description Compressor Harness,Multi

Part Number 5417A20007F 6863A20001X

Location Number Remark 554160 W6631 LGE Internal Use Only

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 59 -

10. LK-1080AH/1080BH/1080CH/1080HH
Exploded View
349600 336610

435301 359012 346810

249950

559010 268711B

546810 152302 W0CZZ

549610

566001

W6920

552111 263230 554160

554031B

330870

554031A

websi te http:// e-mail www. http:// LGEs www. ervice LGEs .com ervice .com/t echsup .html

554031D 554031C

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 60 -

LGE Internal Use Only

11. LK-1580AH/1580CH/LK-1580AHS1/LK-1580AHF
Exploded View
435311

346810 145610A 336610

435512

359012

349480 249951

W4811 145610B

W4400 546810B 559010 354210 152302

567480A

342800 546810A

549610
268711B

261704

W0CZZ

W6631
W6920 566001

552111 567480B 566000

554160 330871 554031

267110

567480C 554030

Model LK-1580AH(F/S1), LK-1580CH

Classication Cooling Only

Description Compressor Harness,Multi

Part Number 5417A20007F 6863A20007E

Location Number 554160 W6631

Remark -

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 61 -

LGE Internal Use Only

12. LK-1580BH/1580HH
Exploded View
435311

346810 145610A 336610

435512

359012

349480 249951

W4811 145610B

W4400 546810B 559010 354210 152302

567480A

342800 546810A

549610
268711B

261704

W0CZZ

W6631
W6920 566001

567480B

552111A

552111B

554160 330871 554031

267110

567480C 554030

Model LK-1580BH, LK-1580HH

Classication Cooling & Heating

Description Compressor Harness,Multi

Part Number 5417A20007F 6863A20007E

Location Number 554160 W6631

Remark -

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 62 -

LGE Internal Use Only

13. LK-2080AH/2080CH
Exploded View
346810 349600A

435311 359012

342800

559010 349600B 546810B

249950

546810A
268711B

261704

W6920

549610

566001

552111 263230

354210

554160

330870

554031A

websi te http:// e-mail www. http:// LGEs www. ervice LGEs .com ervice .com/t echsup .html

554031B

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 63 -

LGE Internal Use Only

Specification of Components
LK-0580HC/BC(S1) LK-0580AC/CC(S) LK-0880HH/BH
P/No Model name *RLA (A) **LRA (A) Q'ty P/No Output Shaft Dia RPM P/No Output Shaft Dia RPM Q'ty P/No Diameter P/No Diameter*width P/No Type P/No Type Outside Dia. P/No Type Length P/No Spec. Rated Voltage Maker P/No Spec. P/No Spec. P/No Spec. P/No FILTER Size Q'ty P/No Spec. P/No Spec. P/No Spec. P/No Spec. 5417A20008G H26A72QDBEA 9.2 79 1 4681A20022F 0.5 (Hp) 15 (mm) 950 4681A20008Z 0.15 12 (mm) 930 2 1A00195B O.D 460 (mm) 2A00578M 270*270 (mm) 0CZZA20001C 12F/450V 2H00841J 6F/370V 5417A20008G H26A72QDBEA 9.2 79 1 4681A20022F 0.5(Hp) 15 (mm) 950 4681A20008Z 0.15 12 (mm) 930 2 1A00195B O.D 460 (mm) 2A00578M 270*270 (mm) 6600A20004C OFF:2.0kgf/ON:3.5kgf DC 24V SAGINOMIYA 0CZZA20001C 12F/450V 2H00841J 6F/370V

LK-0880BHS1

LK-0880AH/CH

COMP

INDOOR MOTOR

OUTDOOR MOTOR

OUTDOOR FAN INDOOR BLOWER MOTOR PULLY BLOWER PULLY

V-VELT

LOWER PRESSURE SWITCH CAPACITOR for COMP CAPACITOR for ***IDM CAPACITOR for ****ODM

TRANSFORMER CONTACTOR for COMP. RELAY for IDM RELAY for ODM

5417A20007F 5417A20007F 5417A20007F H25G104DBVE H25G104DBVE H25G104DBVE 14.5 14.5 14.5 115 115 115 1 1 1 4681A20018B 4681A20018B 4681A20018B 1.5(Hp) 1.5(Hp) 1.5(Hp) 22 (mm) 22 (mm) 22 (mm) 1450 1450 1450 4681A20026D 4681A20026D 4681A20019C 0.5 0.5 0.5 19 (mm) 19 (mm) 15 (mm) 950 950 950 1 1 1 5901A20004A 5901A20004A 1A00284A O.D 660 (mm) O.D 660 (mm) O.D 600 (mm) 5835A20001A 5835A20001A 5835A20001A 320*320 (mm) 320*320 (mm) 320*320 (mm) 3A00217R 3A00217R 3A00217R VARIABLE VARIABLE VARIABLE 4561A30001F 4561A30001F 4561A30001F "A" TYPE "A" TYPE "A" TYPE 149 (mm) 149 (mm) 149 (mm) 4400A30001P 4400A30001P 4400A30001P "A" TYPE "A" TYPE "A" TYPE 48 (inch) 48 (inch) 48 (inch) 6600A20004C OFF:2.0kgf/ON:3.5kgf DC 24V SAGINOMIYA 0CZZA20001E 0CZZA20001E 20F/450V 20F/450V 5230A20003A 5230A20003A 5230A20003A 5230A20003C 5230A20003C 5230A20003C 668*742(mm) 668*742(mm) 668*742(mm) 668*500(mm) 668*500(mm) 668*500(mm) 2 2 2 6171AQ2138E 6171AQ2138E 6171AQ2138D 6171AQ2138D 6171AQ2138D AC 220V,450mA AC 220V,450mA AC 220V,450mA AC 220V,450mA AC 220V,450mA 2A01031A 2A01031A 2A01031A 2A01031A 2A01031A 30A, 220V CONTROL 30A, 220V CONTROL 30A, 220V CONTROL 30A, 220V CONTROL 30A, 220V CONTROL 6920AP3400A 6920AP3400A 6920AP3400A 6920AP3400A 6920AP3400A 220V,25A 220V,25A 220V,25A 220V,25A 220V,25A 6920AP3400A 6920AP3400A 6920AP3400A 6920AP3400A 6920AP3400A 220V,25A 220V,25A 220V,25A 220V,25A 220V,25A ***IDM: INDOOR MOTOR, ****ODM:OUTDOOR MOTOR

*RLA: RATED LOAD AMPER, **LRA: LOCK LOAD AMPER,

Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 64 -

LGE Internal Use Only

LK-1080HH/BH
P/No Model name *RLA (A) **LRA (A) Q'ty P/No Output Shaft Dia RPM 5417A20008G H26A72QDBEA 9.2 79 2 4681A20025C 3 (Hp) 22 (mm) 1500 4681A20026D

LK-1080AH/CH
5417A20008G H26A72QDBEA 9.2 79 2 4681A20025C 3 (Hp) 22 (mm) 1500 4681A20026D

LK-1580HH/BH LK-1580AHS1

LK-1580AH/CH

LK-2080AH/CH

5417A20007F 5417A20007F 5417A20007G H25G104DBVE H26A72QDBEA H25G144DBEE 14.5 14.5 21.6 COMP 115 115 126 2 2 2 4681A20025D 681A20025D 4681A20031D 4 (Hp) 4 (Hp) 5 (Hp) INDOOR MOTOR 22 (mm) 22 (mm) 28 (mm) 1500 1500 3000 4681A20026D 4681A20019C 4681A20026D P/No 4681A20026E 4681A20019E 4681A20026E 1.3 1.3 1.3 0.5 1.3 Output OUTDOOR MOTOR 19 (mm) 19 (mm) 19 (mm) 15 (mm) 19 (mm) Shaft Dia 950 950 950 950 950 RPM 1 1 1/1 1/1 1/1 Q'ty 5901A20004G 5901A20004G 5901A20004A 1A00284A 5901A20004A P/No OUTDOOR FAN O.D 690 (mm) O.D 690 (mm) O.D 660 (mm) O.D 600 (mm) O.D 660 (mm) Diameter 5835A20003A 5835A20003A 5835A20003B 5835A20003B 5835A20003D P/No INDOOR BLOWER 380*280 (mm) 380*280 (mm) 380*380 (mm) 380*380 (mm) 450*454 (mm) Diameter*width 3A00217R 3A00217R 3A00217R 3A00217R 3A00217S P/No MOTOR PULLY VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE Type 4561A30002B 4561A30002B 4561A30002A 4561A30002A 4561A30003C P/No "REC-B" TYPE "REC-B" TYPE "REC-B" TYPE "REC-B" TYPE "REC-B" TYPE BLOWER PULLY Type 190 (mm) 190 (mm) 180 (mm) 180 (mm) 457 (mm) Outside Dia 4400A30002G 4400A30002G 4400A30002G 4400A30002G 4400A30002J P/No "REC-B" TYPE "REC-B" TYPE "REC-B" TYPE "REC-B" TYPE "REC-B" TYPE V-VELT Type 54 (inch) 54 (inch) 54 (inch) 54 (inch) 81 (inch) Length 6600A20004C 6600A20004C 6600A20004C P/No LOWER PRESSURE Spec OFF:2.0kgf/ON:3.5kgf OFF:2.0kgf/ON:3.5kgf OFF:2.0kgf/ON:3.5kgf SWITCH Rated Voltage DC 24V DC 24V DC 24V SAGINOMIYA SAGINOMIYA SAGINOMIYA Maker CAPACITOR P/No for COMP Spec CAPACITOR P/No for ***IDM Spec 0CZZA20001E 0CZZA20001E 0CZZA20001E 0CZZA20001E CAPACITOR P/No 20F/450V 20F/450V 20F/450V 20F/450V for ****ODM Spec 5230A20003D 5230A20003D 5230A20003F 5230A20003F 5230A20003H P/No 938*408(mm) 938*408(mm) 1,374*458(mm) 1,374*458(mm) 750*717(mm) FILTER Size 2 2 2 2 4 Q'ty 3H03750K 3H03750H 3E92334R 3H02633E 3H01535R P/No 3H02633E 5210A30040P 3E92334M CAPILLIARY TUBE I.D1.4*1100(mm) I.D1.4*700(mm) I.D1.4*900(mm) I.D1.6*1000(mm) Spec I.D1.4*900(mm) I.D1.4*800(mm) 9, 9 10, 10, 7, 7 20 20 Q'ty 6171AQ2138D 6171AQ2138D 6171AQ2138D 6171AQ2138D 6171AQ2138E P/No TRANSFORMER AC 220V,450mA AC 220V,450mA AC 220V,450mA AC 220V,450mA AC 220V,450mA Spec 2A01031A 2A01031A 2A01031A 2A01031A 2A01031C P/No CONTACTOR for COMP. Spec 30A, 220V CONTROL 30A,220V CONTROL 30A,220V CONTROL 30A,220V CONTROL 40A,220V CONTROL P/No 6920AP3400A 6920AP3400A 6920AP3400A 6920AP3400A 6920AP3400A RELAY for IDM 220V,25A 220V,25A 220V,25A 220V,25A 220V,25A Spec P/No 6920AP3400A 6920AP3400A 6920AP3400A 6920AP3400A 6920AP3400A RELAY for ODM Spec 220V,25A 220V,25A 220V,25A 220V,25A 220V,25A *RLA: RATED LOAD AMPER, **LRA: LOCK LOAD AMPER, ***IDM: INDOOR MOTOR, ****ODM:OUTDOOR MOTOR Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes

- 65 -

LGE Internal Use Only

P/NO : 3828A30027F

AUGUST, 2009