Вы находитесь на странице: 1из 9

Printed from Grundfos CAPS [2012.01.

059]

1/9

Product name CRN 64-2-2

Phase 3

U [V] 380-480 D/660-690 Y

P2 [HP] 20.1

Pump outlet DN 100

Q actual [US GPM] 302

H actual [ft] 158

Energy [kWh/a] 15043

Energy costs [] 2256.45

Printed from Grundfos CAPS [2012.01.059]

2/9

Description Product name: Product No: EAN number: Technical: Speed for pump data Actual calculated flow: Resulting head of the pump: Impellers: Impeller reduc.: Shaft seal: Stages: Pump version: Model: Materials: Pump housing:

Value CRN 64-2-2 A-F-G-V-HQQV 96123944 5700396702155

H (ft) 180 160 140

CRN 64-2-2

3* 440 V, 60 Hz

eta (%)

3528 rpm 302 US GPM 158 ft 2 2 HQQV 2 A A

120 100

Impeller:

Material code: Code for rubber: Installation: Maximum ambient temperature: Max pressure at stated temp Flange standard: Connect code: Pipe connection: Pressure stage: Flange size for motor: Liquid: Liquid temperature range Liquid temp: Density: Electrical data: Motor type: IE Efficiency class: Number of poles: Rated power - P2: Power (P2) required by pump Mains frequency: Rated voltage: Rated current: Starting current Cos phi - power factor: Rated speed: IE efficiency: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Motor protec: Motor No: Others: Net weight: Gross weight: Shipping volume:

Stainless steel DIN W.-Nr. 1.4408 AISI 316 LN Stainless steel DIN W.-Nr. 1.4401 AISI 316 G V

80 Q = 302 US GPM 80 60 H = 158 ft 60 n = 3556 rpm 40 40 Pumped liquid = Water 20 20 Liquid temperature = 68 F Eta pump = 71.4 % Density = 62.29 lb/ft Eta pump+motor = 66.6 % 0 0 0 50 100 150 200 250 300 350 Q(US GPM) P NPSH (HP) (ft) P1 P2 16 25 20 12 15 8 10 P2 = 16.9 HP 4 5 P1 = 13.5 kW 0 0
7 13/16 "

140 F 232 psi / 194 F 232 psi / -4 F DIN F DN 100 PN 16 FF300

12 5/8 "

-4 .. 194 F 68 F 62.4 lb/ft


G 1/2 29.7 "

18.5 "

13 13/16 "

PN16
G 1/2 8 x 18

TO AMPLIFIER

386 lb 459 lb 13.8 ft

RELAY

L1

L2

L3

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

Printed from Grundfos CAPS [2012.01.059]

IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082

160MD IE2 - IE3 2 20.1 HP 20.1 HP 60 Hz 3 x 380-480 D/660-690 Y V 28,0-22,4/16,2-15,6 A 580-890 % 0,90-0,86 3520-3550 rpm IE2 90,2% - IE3 91,0% 90,2-91,0 % 91,8-92,3 % 92,1-91,3 % 55 (Protect. water jets/dust) F PTC 85U17526

150

140

190 251 365

45

100 266 331

4 x 14

+T

+T

+T

180

220

G 1/2

3/9

96123944 CRN 64-2-2 60 Hz


H (ft) 200 CRN 64-2-2 3* 440 V, 60 Hz eta (%) Q = 302 US GPM H = 158 ft n = 3556 rpm Pumped liquid = Water Liquid temperature = 68 F Density = 62.29 lb/ft

180

160

140

120

100

80

80 70

60

60 50

40

40 30

20

20 10 Eta pump = 71.4 % Eta pump+motor = 66.6 % 0 350 400 Q(US GPM) NPSH (ft) 35

0 0 P (HP)

50

100

150

200

250

300

20

P1 P2

30 25 20 15

16

12

8 10 4 5 P2 = 16.9 HP P1 = 13.5 kW 0 4/9

0
Printed from Grundfos CAPS [2012.01.059]

96123944 CRN 64-2-2 60 Hz


cos phi eta 1 eta cos phi CRN 64-2-2 + 160MD 20.1 HP 3* 440 V, 60 Hz I (A) 50

0.8

40

I 0.6 30

0.4

20

0.2

10

0 0 n (rpm)

10

12

14

16

18

20

22

P2 = 16.9 HP cos phi = 0.87 eta = 93.3 % I = 20.4 A 0 24 26 P2(HP) P1 (kW) n

3200

30

P1 2800 20

2400

10

P1 = 13.5 kW n = 3556 rpm 0


Printed from Grundfos CAPS [2012.01.059]

5/9

96123944 CRN 64-2-2 60 Hz

7 13/16 " 12 5/8 "

18.5 "

13 13/16 "

G 1/2

PN16
29.7 " G 1/2 8 x 18

150

140

190 251 365

45

100 266 331

4 x 14

Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. Printed from Grundfos CAPS [2012.01.059]

180

220 6/9

G 1/2

96123944 CRN 64-2-2 60 Hz

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

Note! All units are in [mm] unless others are stated. Printed from Grundfos CAPS [2012.01.059]

IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082

7/9

96123944 CRN 64-2-2 60 Hz


Input Select Application Overview mode Yes Industrial applications Water Treatment Filtration 264 US GPM 121 ft Water 50 F 68 F Inlet pressure Uncontrolled Single 2 2 8 Price + energy costs 0.15 6% 1113.25 h/a 5 years 60 Hz 1 or 3 5.5 kW Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Sizing result Type CRN 64-2-2 Quantity 1 Motor 20.1 HP Flow Head Power P1 Power P2 Eta pump Eta motor Eta pump+motor

Input overview: Select Type of Installation Select subapplication Dimensioning flow Total head Pumped liquid Min. liquid temperature Liquid temperature during operation Installation type Variable speed Select type of hydraulic Preferred number of poles Max. hits per product group Max. hits total Evaluation criterion Energy price Increase of energy price Pump operating time Calculation period Frequency Phase Min. power limit for SD start Immersible Immersible horizontal Inline Multistage Inline single stage End-suction long-coupled End-suction close coupled End-suction close coupled vertical singlestage End-suction close coupled horizontal multistage End-suction singlestage pump with semi-open impeller MTB Encapsulated Horizontal splitcase Select extra options for selected pump Lifecycle cost calculation Load Profile 1 Flow 100 Head 131 P1 18.1 Eta total 66.6 Time 1113 Energy consumption 15043 Quantity 1 % % kW % h/Year kWh/Year

US GPM ( +14%) ft ( +31%) kW HP % % % =Eta pump * Eta motor Eta total 66.6 % =Eta relative to the duty point Energy consumption 15043 kWh/Year CO2 emission 19000 lb/Year Price On request Price + energy costs (1) /5Years

302 158 13.5 16.9 71.4 93.3 66.6

H (ft) 180 160 140 120 100 80 60

CRN 64-2-2

3* 440 V, 60 Hz

eta (%)

Q = 302 US GPM H = 158 ft 40 n = 3556 rpm Pumped liquid = Water 20 Liquid temperature = Eta 68 pump F = 71.4 % Density = 62.29 lb/ft Eta pump+motor = 66.6 % 0 0 50 100 150 200 250 300 Q(US GPM) P NPSH (HP) (ft) P1 30 P2 16 25 20 12 15 8 10 P2 = 16.9 HP 5 4 P1 = 13.5 kW 0 0

80 70 60 50 40 30 20 10 0

Printed from Grundfos CAPS [2012.01.059]

8/9

Order Data:
CRN 64-2-2 A-F-G-V-HQQV Product No 96123944 Total: Price on request

Printed from Grundfos CAPS [2012.01.059]

9/9