This drawing and design is the property of Plans & Planning and should not be produced without written

permission. Contractors are to check all levels and dimensions on site prior to site works commencement.

Velux GGL size S08 roof lights. Installed to manufacturers instructions.

LEAN TO ROOF CONSTRUCTION Min 22.5degree roof - Slates to match existing on 38 x 25mm tanalised softwood battens on Monarfol 250 roofing felt by Monarflex Ltd. or equal, on Roof structure as detailed in Eng. Notes. Galvanised steel wall plate holding down straps at 1m cenres. 150 x 75mm tanalised softwood wall plate. 150mm Rockwool Rollbatts laid between the joists with 100mm Rollbatts laid above the joists. Minimum 50mm air space to be left between the Rollbatts and felt at the eaves for through ventilation of the attic space. 12.5mm plasterboard and skim ceiling, all to give a min U value of 0.16W/m2K.

Roll lead roof - installed to Leads Council Guidlines

BRICKWALL CONSTRUCTION Brickwork to match existing. 100mm outer leaf of brickwork, 100mm cavity and 100mm inner blockwork with a thermal conductivity of 0.19W/mK. 85mm insulation to be laid in accordance with the manufactures instructions, giving a 'U' value of 0.35 W/mk. A 13mm plaster finish to inside face. 76-100mm CAVITY WIDTH walls to be tied together with stainless steel vertical twist type ties - inner leaf and outer leaf - ties at maximum centres of 750mm horizontally, 450mm vertically staggered and 300mm centres vertically around all openings if not joined by bonded jambs. Cavity to be closed at eaves, jamb and cill with vertical insulating dpc positioned in cavity prior to installation of window frame. 150mm wide vertical dpc's should be nailed to the full height of frames and should protrude into the cavity by 25mm and extend up to the underside of the lintel where it should be turned back towards the inner leaf. 150mm wide vertical dpc's to all jambs of external openings in cavity walls linked to horizontal dpc's. Vertical dpc's to be taken to outer face of joinery and mastic pointed. At cills dpc to be placed between cill and the outer leaf, turned up the back and ends of the cill. Ruberoid Hyload damp proof course system to BS 6398 1983 or equal approved. Horizontal damp proof course minimum 150mm above finished ground level, linked to dpm. Catnic intels or equal to suit all openings. All lintels to be installed in accordance with the manufacturers recommendations, to be correct size and have correct bearing at each end. Cavity tray provided over openings where appropriate protection not provided as integral part of lintel. Dpc cavity tray over external lintels should extend 150mm beyond the end of the lintel with a minimum 140mm total rise in cavity tray. Stop ends to all cavity trays with weep holes provided at maximum 450mm intervals. (min. 2 weep holes per opening). Cavity trays also to be provided where the cavity is bridged by air bricks and over meter boxes. FLASHINGS Code 4 lead to be dressed min. 150mm where appropriate to abutments, with cavity tray above this level. All leadwork to be in accordance with the Lead Development Council. Cavity trap to be provided to all abutments.

SHWR
Room Ht=

BDRM2

2485

Room Ht=

BATH

2486

Room Ht=

BDRM4

2485

Under NO circumstances must dimensions be scaled from this drawing. All contractors must be responsible for taking and checking all dimensions upon visiting site. All contractors must advise of any discrepancies immediately in writing. All design work and information provided on this drawing remains the property of Plans & Planning and must under NO circumstances be reproduced in any form without prior written approval. This drawing is to be read in conjunction with the bill of quantities/specification and any related drawing. The contractor is responsible for ensuring all items are included when tendering even if not covered by the specification. All such items must be advised of in writing. Any structural alterations must be carried out in accordance with any structural drawings issued. All structural work to be inspected at each relevant stage by the Structural Engineer and the Building Inspector, any changes must have their express written approval. Any costs incurred due to either claims for damages, loss of trade etc by failing to do so will be the sole liability of the contractor. All works must be carried out in strict accordance with all Local Authority, British & European Standards. If in doubt, it is the responsibility of the contractor to contact all relevant parties. All dimensions are approximate sizes and all contractors should verify sizes on site prior to commencing any works.

BATH

LNDG

STUDY

Location - scale 1:1250

Lead Flat roof


Rafters150x50 SC4 at 400 (as per eng notes)

Details of Strip Foundation and Steelwork See drawing SE100


NEW WINDOWS Windows as specified elswhere - each to have new 'Catnic' type lintel above window. 1 in 4 perps to be left clear to allow cavity drainage.

For Steelwork & roof construction see SE100 and eng Notes Ceiling Lined with 12.5mm Plasterboard

KITCH/DINING

TO UTILITY

TO WC

HALL

Room Ht=

BDRM1

2486

STUDY
Room Ht=

2485

Room Ht=

BDRM3

2486

Full fill Cavity Insulation - (installed to manfcts instructions) 22mm Moisture resitant T&G Chipboard Rockwool ``flexi'' between joists Tanalised battons to support insulation

Stone Paving

DPC MIN 150mm AGL

Perimeter edge insulation between joist & wall Ventilated air space (min 150mm below joists) Concrete subfloor (min 100mm) Hardcore Subsoil Weak mix 1:3:6 concrete cavity infill below ground level

Joist supported on Hanging Brackets


1

DATUM
3 Scale: 1:50

PROPOSED 1st FLOOR

Galvanised MS. Wall ties at 900mm horizontal centres and 450mm vertical centres.

PROPOSED CROSS SECTION

Scale: 1:50

2 A301

Depth sufficient to avoid ground movement - minimum 600 MM MIN 1000mm Class B Engineering BWK below DPC If there are any drains within 1000mm of the foundations then foundations to be lower than drains

150 MM MIN

DATUM

NEW TIMBER FLOORS TO EXTENDED GROUND FLOOR to be formed using 22mm moisture resistant t&g chipboard on softwood SC4 170x47 timber joists at 400mm centers. Fix 100 x 50mm cross noggings to stiffen unsupported ends of t&g at perimeter of room and at board joints. All joists are to have ends treated with 3 coats of green cuprinol and are to be wrapped in dpc prior to fixing to joist hangers/ pfc to external and internal walls. INSULATION As shown or alternatively - 100mm min KINGSPAN supported on tanalised battons under suspended floor. VENTILATION Airbricks installed in new external wall to manfct instructions.

2.70
CATNIC CG70/100 2550-3900

Sheet Index
5.93 New Softwood windows to match existing. CATNIC CG70/100 750-1800
No
BR100 BR101 BR201 SE100

Party Wall Act 1996 The above Act applies to work on a wall shared with another property or to a new building on a boundary shared with another property. Or an excavation near a neighbouring building. Cosequentialy the woks come under the auspices of the legislation. Therefore to satisfy the legal requirements of the ACT the affected neighbour should be notified in writing of the proposal and their agreement sought, prior to work commencing.

CONTENTS
GENERAL NOTES Floor Plans & Section External Elevations Structural

ELECTRICS AND LIGHTING - (GENERAL)


Electrical services shall be designed and installed in accordance with the latest amendments of the niceic and iee regulations and installed in accordance with Part P of the Building Regulations for the safety of electrical installations for buildings. See wiring regulations (bs 7671) Light switches and sockets outlets shall be located at appropriate heights between 450 and 1200mm above the finished floor level. consumer units, fan isolation switches and cooker hood supplies shall be located at high level outside this zone. cables shall be run behind earthed metal capping, and not chased into masonry walls. Where cabling is run within metal stud partitions, proprietary grommets are to be used as detailed by the manufacturer to protect the cables from chafing on the studs. Cables should not be placed under, against or within thermal insulation, unless indicated in the design. for further guidance, refer to the bre report 'thermal insulation: avoiding risks'. pvc covered cables should not be in contact with polystyrene insulation. All installations are to be to the current edition of BS7671.1992 (the requirements for electrical installation) and to meet the requirements of approval document part P. All subcontractors are to be nic registered & to provide the appropriate completion certificate for each property. See specification for required manufacturer of items. All cable used is to be basec approved. VENTILATION TO KITCHEN Rapid ventilation To be provided by means of an extract fan capable of extracting at a rate not less than 60 litres per second, or cooker hood capable of extracting a a rate of 30 litres per second direct to the external air. Natural ventilation To be provided by one or more ventilation openings with a total area of at least 1/20th of the floor area of the room, with part of that opening at least 1.75m above the finished floor level. Background ventilation To be provided by trickle ventilators positioned in the window head which should be controllable and secure having a total area not less that 4000 square millimeteres. Maintain min. 10mm air gap beneath door.

NEW KITCHEN/DINING ROOM 3.71

FLOOR GROUND FIRST SECOND TOTALS

EXISTING

56 74 0 130

PROPOSED

72 74

CHANGE

16 0 #

3.31 5.20

INTERNAL STUD WALLS To be constructed of 100 x 50mm softwood studs at 600mm centres with noggings at max. 1200mm centres. Sound insulation by filling cavinty with mineral wool-Dense Fibre Matting - and High Density Acoustic plasterboard.

146

16

Rev. Date
A 12/11/08

Description
FOR APPROVAL

Details of Steelwork See drawing SE100

4.16 1.18 Side window replaced by new door and stone step.
CATNIC CG70/100 750-1800

EXISTING PARTITIONS/INTERNAL WALLS Before the removal of existing walls, check with structural engineer as to whether loadbearing and request size and specification of new lintel. Carefully remove existing wall, insert new lintel and make good to floor, wall and ceiling, with finishes to match and line through with existing. Note - check and remove existing services as necessary.

Room Ht=

LOUNGE

Client

2575

1.91

NEW UTILITY

UTILITY

WASHER

DRYER

Windsor Ave Wilmslow


CARPORT
Room Ht= 2500

Project

Single Storey extension To Rear Full Plans Application

EXISTING DRAINS No drain survey has been carried out - positions of existing drains are approximate.

Drawing Title

FLOOR PLANS & SECTION

Surveyed & Drawn by

SITTING
Room Ht=

2575

Room Ht=

HALL

2600

plansandplanning
Petworth Lodge, 1a Hillbrook Rd Bramhall SK7 2BT Tel: 0161 439 4874 www.fogcitydrafting.co.uk pfkirk@fogcitydrafting.co.uk

Drawn By
PROPOSED GROUND FLOOR
1 A301

PFK GF 23/6/08

Survey Date

Checked by
Scale: 1:50

Scale

1:50
Revision

DATUM

Drawing No

BR101

This drawing and design is the property of Plans & Planning and should not be produced without written permission. Contractors are to check all levels and dimensions on site prior to site works commencement.

RIDGE

RIDGE

7.94

7.94

Under NO circumstances must dimensions be scaled from this drawing. All contractors must be responsible for taking and checking all dimensions upon visiting site. All contractors must advise of any discrepancies immediately in writing. All design work and information provided on this drawing remains the property of Plans & Planning and must under NO circumstances be reproduced in any form without prior written approval. This drawing is to be read in conjunction with the bill of quantities/specification and any related drawing. The contractor is responsible for ensuring all items are included when tendering even if not covered by the specification. All such items must be advised of in writing. Any structural alterations must be carried out in accordance with any structural drawings issued. All structural work to be inspected at each relevant stage by the Structural Engineer and the Building Inspector, any changes must have their express written approval. Any costs incurred due to either claims for damages, loss of trade etc by failing to do so will be the sole liability of the contractor. All works must be carried out in strict accordance with all Local Authority, British & European Standards. If in doubt, it is the responsibility of the contractor to contact all relevant parties. All dimensions are approximate sizes and all contractors should verify sizes on site prior to commencing any works.

1ST FCE

1ST FCE

2.49

2.49

Location - scale 1:1250


5.30 5.30

1ST FFE GRND FCE

1ST FFE GRND FCE

2.60

2.81

2.60

2.81

CAR PORT

GRND FFE

GRND FFE

DATUM
4

DATUM
PROPOSED NORTH ELEVATION
Scale: 1:50 3

PROPOSED EAST ELEVATION

Scale: 1:50

Sheet Index
No
BR100 BR101 BR201 SE100

CONTENTS
GENERAL NOTES Floor Plans & Section External Elevations Structural

FLOOR GROUND FIRST SECOND TOTALS

EXISTING

RIDGE

RIDGE

56 74 0 130

PROPOSED

72 74

CHANGE

16 0 #

146

16

Rev. Date
A 7.94 7.94 12/11/08

Description
FOR APPROVAL

Client

1ST FCE

1ST FCE

Windsor Ave Wilmslow


2.49

2.49

Project

Single Storey extension To Rear Full Plans Application

5.30

5.30

Drawing Title
1ST FFE GRND FCE 1ST FFE GRND FCE

ELEVATIONS

Surveyed & Drawn by

2.60

2.81

2.60

2.81

plansandplanning
CAR PORT
Petworth Lodge, 1a Hillbrook Rd Bramhall SK7 2BT Tel: 0161 439 4874 www.fogcitydrafting.co.uk pfkirk@fogcitydrafting.co.uk

GRND FFE

GRND FFE

DATUM
2

DATUM
1

Drawn By

PFK GF 23/6/08

Survey Date

PROPOSED WEST ELEVATION

Scale: 1:50

PROPOSED EAST ELEVATION

Checked by

Scale

Scale: 1:50

1:50
Revision

Drawing No

BR201