Mechanical Anchoring Systems
4.3.4 Kwik Bolt TZ Expansion Anchor
Listings/Approvals
ICC-ES (International Code Council)
ESR-1917
FM (Factory Mutual)
Pipe Hanger Components for Automatic
Sprinkler Systems (3/8" - 3/4")
UL (Underwriters Laboratories)
Pipe Hanger Equipment for Fire
Protection Services (3/8" - 3/4")
Impact Section
(Dog Point)
Expansion Cone
Nut
Washer
Red
Setting
Mark
Anchor
Body
Stainless
Steel
Expansion
Sleeve
(Wedges)
Anchor
Thread
4.3.4.1 Product Description
4.3.4.2 Material Specifications
4.3.4.3 Technical Data
4.3.4.4 Installation Instructions
4.3.4.5 Ordering Information
4.3.4.6 Sample Calculation
The Kwik Bolt TZ (KB-TZ) is a torque
controlled expansion anchor which is
especially suited to seismic and cracked
concrete applications. This anchor line
is available in carbon steel with zinc
electroplated coating and 304 stainless
steel versions. The anchor diameters
range from 3/8 to 3/4 inch in a variety of
lengths. Applicable base materials
include normal-weight concrete,
structural lightweight concrete, and
lightweight concrete over metal deck.
Guide Specifications
Torque controlled expansion anchors
shall be Kwik Bolt TZ (KB-TZ) supplied
by Hilti meeting the description in
Federal Specification A-A 1923A, Type
4. The anchor bears a length
identification mark embossed into the
impact section (dog point) of the anchor
surrounded by four embossed notches
identifying the anchor as a Hilti Kwik
Bolt TZ in the installed condition.
Anchors are manufactured to meet one
of the following conditions:
The carbon steel anchor body, nut,
and washer have an electroplated
zinc coating conforming to ASTM
B 633 to a minimum thickness of 5
m. The stainless steel expansion
sleeve conforms to AISI 316.
Stainless steel anchor body, nut
and washer conform to AISI 304.
Stainless steel expansion sleeve
conforms to AISI 316.
Product Features
Product and length identification
marks facilitate quality control after
installation.
Through fixture installation and
variable thread lengths improve
productivity and accommodate
various base plate thicknesses.
316 Stainless Steel wedges pro-
vide superior performance in
cracked concrete.
Ridges on expansion wedges
provide increased reliability.
Mechanical expansion allows
immediate load application.
Raised impact section (dog point)
prevents thread damage during
installation.
Bolt meets ductility requirements
of ACI 318-05 Section D1.
Installation
Drill hole in base material to the
appropriate depth using a Hilti carbide
tipped drill bit. Drive the anchor into the
hole using a hammer. A minimum of four
threads must be below the fastening
surface prior to applying installation
torque. Tighten the nut to the
recommended installation torque.
4.3.4.1 Kwik Bolt TZ Product Description
Supplemental Design Provisions for ACI 318-05 Appendix D
Design strengths are determined in accordance with ACI 318-05 Appendix D and
ICC Evaluation Service ESR-1917 Hilti Kwik Bolt TZ Carbon and Stainless Steel
Anchors in Concrete. The relevant design parameters are reiterated in Tables 1, 2,
and 3 of this document. Supplemental provisions required for the design of the
KB-TZ are enumerated in Section 4.0 of ESR-1917 (DESIGN AND INSTALLATION).
Note that these design parameters are supplemental to the design provisions
of ACI 318-05.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006 213
Mechanical Anchoring Systems
Kwik Bolt TZ Expansion Anchor 4.3.4
4.3.4.2 Material Specifications
Carbon steel with electroplated zinc
Carbon steel KB-TZ anchors have the following minimum bolt fracture loads
1
Carbon steel anchor components plated in accordance with ASTM B 633 to a minimum thickness of 5m.
Nuts conform to the requirements of ASTM A 563, Grade A, Hex.
Washers meet the requirements of ASTM F 844.
Expansion sleeves (wedges) are manufactured from AISI 316 stainless steel.
Stainless steel
Stainless steel KB-TZ anchors are made of AISI 304 material and have the following minimum bolt fracture loads
1
Nuts meet the dimensional requirements of ASTM F 594.
Washers meet the dimensional requirements of ANSI B18.22.1, Type A, plain.
Expansion Sleeve are made from AISI 316.
All nuts and washers are made from AISI 304 stainless steel.
1 Bolt fracture loads are determined by testing in jig as part of product QC. These loads are not intended for design purposes. See Tables 2 and 3.
Anchor Shear Tension
Diameter (in.) (lb) (lb)
3/8 NA 6744
1/2 7419 11240
5/8 11465 17535
3/4 17535 25853
Anchor Shear Tension
Diameter (in.) (lb) (lb)
3/8 5058 6519
1/2 8543 12364
5/8 13938 19109
3/4 22481 24729

214 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006
Mechanical Anchoring Systems
4.3.4 Kwik Bolt TZ Expansion Anchor
4.3.4.3 Technical Data
Table 1 Kwik Bolt TZ Specification Table
SETTING
Symbol Units
Nominal anchor diameter (in.)
INFORMATION 3/8 1/2 5/8 3/4
Anchor O.D. d
o
in. 0.375 0.5 0.625 0.75
(mm) (9.5) (12.7) (15.9) (19.1)
Nominal bit
d
bit
in. 3/8 1/2 5/8 3/4
diameter
Effective min.
h
ef
in. 2 2 3-1/4 3-1/8 4 3-3/4 4-3/4
embedment (mm) (51) (51) (83) (79) (102) (95) (121)
Min. hole depth h
o
in. 2-5/8 2-5/8 4 3-3/4 4-3/4 4-5/8 5-3/4
(mm) (67) (67) (102) (95) (121) (117) (146)
Min. thickness of
t
min
in. 1/4 3/4 1/4 3/8 3/4 1/8 1-5/8
fixture
1
(mm) (6) (19) (6) (9) (19) (3) (41)
Max. thickness of
t
max
in. 2-1/4 4 2-3/4 5-5/8 4-3/4 4-5/8 3-5/8
fixture (mm) (57) (101) (70) (143) (121) (117) (92)
Installation torque T
inst
ft-lb 25 40 60 110
(Nm) (34) (54) (81) (149)
Min. dia. of hole
d
h
in. 7/16 9/16 11/16 13/16
in fixture (mm) (11.1) (14.3) (17.5) (20.6)
Available anchor

anch
in. 3 3-3/4 5 3-3/4 4-1/2 5-1/2 7 4-3/4 6 8-1/2 10 5-1/2 8 10
lengths (mm) (76) (95) (127) (95) (114) (140) (178) (121) (152) (216) (254) (140) (203) (254)
Threaded length

thread
in. 7/8 1-5/8 2-7/8 1-5/8 2-3/8 3-3/8 4-7/8 1-1/2 2-3/4 5-1/4 6-3/4 1-1/2 4 6
including dog point (mm) (22) (41) (73) (41) (60) (86) (178) (38) (70) (133) (171) (38) (102) (152)
Unthreaded length
unthr
in. 2-1/8 2-1/8 3-1/4 4
(mm) (54) (54) (83) (102)
Installation
h
nom
in. 2-1/4 2-3/8 3-5/8 3-5/8 4-1/2 4-3/8 5-3/8
embedment (mm) (57) (60) (92) (92) (114) (111) (137)
1 The minimum thickness of the fastened part is based on use of the anchor at minimum embedment and is controlled by the length of thread. If a thinner fastening thickness is
required, increase the anchor embedment to suit.
Figure 1 Kwik Bolt TZ installed
t
d
h
d
o
anch
unthr
thread
h
ef
h
o
h
nom
DESIGN Symbol Units Nominal anchor diameter
INFORMATION 3/8 1/2 5/8 3/4
Anchor O.D. d
o
in. 0.375 0.5 0.625 0.75
(mm) (9.5) (12.7) (15.9) (19.1)
Effective min.
h
ef
in. 2 2 3-1/4 3-1/8 4 3-3/4 4-3/4
embedment
1
(mm) (51) (51) (83) (79) (102) (95) (121)
Min. member thickness h
min
in. 4 5 4 6 6 8 5 6 8 6 8 8
(mm) (102) (127) (102) (152) (152) (203) (127) (152) (203) (152) (203) (203)
Critical edge distance c
ac
in. 4-3/8 4 5-1/2 4-1/2 7-1/2 6 6-1/2 8-3/4 6-3/4 10 8 9
(mm) (111) (102) (140) (114) (191) (152) (165) (222) (171) (254) (203) (229)
c
a,min
in. 2-1/2 2-3/4 2-3/8 3-5/8 3-1/4 4-3/4 4-1/8
Min. edge distance
(mm) (64) (70) (60) (92) (83) (121) (105)
for s in. 5 5-3/4 5-3/4 6-1/8 5-7/8 10-1/2 8-7/8
(mm) (127) (146) (146) (156) (149) (267) (225)
s
min
in. 2-1/2 2-3/4 2-3/8 3-1/2 3 5 4
Min. anchor spacing
(mm) (64) (70) (60) (89) (76) (127) (102)
for c
in. 3-5/8 4-1/8 3-1/2 4-3/4 4-1/4 9-1/2 7-3/4
(mm) (92) (105) (89) (121) (108) (241) (197)
Min. hole depth
h
o
in. 2-5/8 2-5/8 4 3-7/8 4-3/4 4-5/8 5-3/4
in concrete (mm) (67) (67) (102) (98) (121) (117) (146)
Min. specified
f
y
lb/in
2
100000 84800 84800 84800
yield strength (N/mm
2
) (690) (585) (585) (585)
Min. specified
f
u
lb/in
2
125000 106000 106000 106000
ult. strength (N/mm
2
) (862) (731) (731) (731)
Effective tensile
A
se
in
2
0.052 0.101 0.162 0.237
stress area (mm
2
) (33.6) (65.0) (104.6) (152.8)
Steel strength
N
sa
lb 6500 10705 17170 25120
in tension (kN) (28.9) (47.6) (76.4) (111.8)
Steel strength
V
sa
lb 3595 6405 10555 15930
in shear (kN) (16.0) (28.5) (47.0) (70.9)
Steel strength in
V
s,seis
lb 2255 6405 10555 14245
shear, seismic (kN) (10.0) (28.5) (47.0) (63.4)
Steel strength in shear,
V
s,deck
lb 2130 3000 4945 4600 6040
NP
concrete on metal deck
2
(kN) (9.5) (13.3) (22) (20.5) (26.9)
Pullout strength
N
p,uncr
lb 2515
NA
5,515
NA
9,145 8,280 10,680
uncracked concrete
3
(kN) (11.2) (24.5) (40.7) (36.8) (47.5)
Pullout strength
N
p,cr
lb 2270
NA
4,915
NA NA
cracked concrete
3
(kN) (10.1) (21.9)
Pullout strength concrete
N
p,deck,cr
lb 1460 1460 2620 2000 4645
NP
on metal deck
4
(kN) (6.5) (6.5) (11.7) (8.9) (20.7)
Anchor category
5
1
Effectiveness factor k
uncr
uncracked concrete 24
Effectiveness factor k
cr
cracked concrete
6
17

c,N
= k
uncr
/k
cr
7
1.41
Strength reduction factor for tension,
steel failure modes
8
0.75
Strength reduction factor for shear, steel
failure modes
8
0.65
Strength reduction factor for tension, concrete
failure modes, Condition B
9
0.65
Strength reduction factor for shear, concrete
failure modes
0.70
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006 215
Mechanical Anchoring Systems
Kwik Bolt TZ Expansion Anchor 4.3.4
Table 2 Carbon Steel Kwik Bolt TZ Design Information
1 See Fig. 1.
2 NP (not permitted) denotes that the condition is not supported.
3 NA (not applicable) denotes that this value does not control for
design.
4 NP (not permitted) denotes that the condition is not supported.
Values are for cracked concrete. Values are applicable to both
static and seismic load combinations.
5 See ACI 318 D.4.4.
6 See ACI 318 D.5.2.2.
7 See ACI 318 D.5.2.6.
8 The KB-TZ is a ductile steel element as defined by ACI 318 D.1.
9 For use with the load combinations of ACI 318 9.2. Condition B
applies where supplementary reinforcement in conformance with
ACI 318 D.4.4 is not provided, or where pullout or pryout strength
governs. For cases where the presence of supplementary rein-
forcement can be verified, the strength reduction factors
associated with Condition A may be used.
DESIGN Symbol Units Nominal anchor diameter
INFORMATION 3/8 1/2 5/8 3/4
Anchor O.D. d
o
in. 0.375 0.5 0.625 0.75
(mm) (9.5) (12.7) (15.9) (19.1)
Effective min.
h
ef
in. 2 2 3-1/4 3-1/8 4 3-3/4 4-3/4
embedment
1
(mm) (51) (51) (83) (79) (102) (95) (121)
Min. member thickness h
min
in. 4 5 4 6 6 8 5 6 8 6 8
(mm) (102) (127) (102) (152) (152) (203) (127) (152) (203) (152) (203)
Critical edge distance c
ac
in. 4-3/8 3-7/8 5-1/2 4-1/2 7-1/2 6 7 8-7/8 6 10 7 9
(mm) (111) (98) (140) (114) (191) (152) (178) (225) (152) (254) (178) (229)
c
a,min
in. 2-1/2 2-7/8 2-1/8 3-1/4 2-3/8 4-1/4 4
Min. edge distance
(mm) (64) (73) (54) (83) (60) (108) (102)
for s
in. 5 5-3/4 5-1/4 5-1/2 5-1/2 10 8-1/2
(mm) (127) (146) (133) (140) (140) (254) (216)
s
min
in. 2-1/4 2-7/8 2 2-3/4 2-3/8 5 4
Min. anchor spacing
(mm) (57) (73) (51) (70) (60) (127) (102)
for c
in. 3-1/2 4-1/2 3-1/4 4-1/8 4-1/4 9-1/2 7
(mm) (89) (114) (83) (105) (108) (241) (178)
Min. hole depth
h
o
in. 2-5/8 2-5/8 4 3-3/4 4-3/4 4-5/8 5-3/4
in concrete (mm) (67) (67) (102) (95) (121) (117) (146)
Min. specified
f
y
lb/in
2
92000 92000 92000 76125
yield strength (N/mm
2
) (634) (634) (634) (525)
Min. specified
f
u
lb/in
2
115000 115000 115000 101500
ult. strength (N/mm
2
) (793) (793) (793) (700)
Effective tensile
A
se
in
2
0.052 0.101 0.162 0.237
stress area (mm
2
) (33.6) (65.0) (104.6) (152.8)
Steel strength
N
sa
lb 5980 11615 18630 24055
in tension (kN) (26.6) (51.7) (82.9) (107.0)
Steel strength
V
s
lb 4870 6880 11835 20050
in shear (kN) (21.7) (30.6) (52.7) (89.2)
Steel strength in tension,
N
seis
lb
NA
2,735
NA NA NA
seismic
2
(kN) (12.2)
Steel strength in shear,
V
seis
lb 2825 6880 11835 14615
seismic
2
(kN) (12.6) (30.6) (52.6) (65.0)
Pullout strength
N
p,uncr
lb 2630
NA
5760
NA NA
12040
uncracked concrete
2
(kN) (11.7) (25.6) (53.6)
Pullout strength cracked
N
p,cr
lb 2340 3180
NA NA
5840 8110
NA
concrete
2
(kN) (10.4) (14.1) (26.0) (36.1)
Anchor category
3
1
Effectiveness factor k
uncr
uncracked concrete 24
Effectiveness factor k
cr
cracked concrete
4
17 24 17 17 17 24 17

c,N
= k
uncr
/k
cr
5
1.41 1.00 1.41 1.41 1.41 1.00 1.41
Strength reduction factor for tension, steel
failure modes
6
0.75
Strength reduction factor for shear, steel
failure modes
6
0.65
Strength reduction factor for tension,
concrete failure modes, Condition B
7
0.65
Strength reduction factor for shear,
concrete failure modes
0.70
216 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006
Mechanical Anchoring Systems
4.3.4 Kwik Bolt TZ Expansion Anchor
Table 3 Stainless Steel Kwik Bolt TZ Design Information
1 See Fig. 1.
2 NA (not applicable) denotes that this value does not control for design.
3 See ACI 318 D.4.4.
4 See ACI 318 D.5.2.2.
5 See ACI 318 D.5.2.6.
6 The KB-TZ is a ductile steel element as defined by ACI 318 D.1.
7 For use with the load combinations of ACI 318 9.2. Condition B applies where supplementary reinforcement in conformance with ACI 318
D.4.4 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be
verified, the strength reduction factors associated with Condition A may be used.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006 217
Mechanical Anchoring Systems
Kwik Bolt TZ Expansion Anchor 4.3.4
Figure 2 Interpolation of Minimum Edge Distance and Anchor Spacing
Figure 3 Installation in Concrete over Metal Deck Floor
Table 4 Mean Axial Stiffness Values (1000 lb/in.) for Kwik Bolt TZ Carbon
and Stainless Steel Anchors in Normal-Weight Concrete
1
Concrete condition carbon steel KB-TZ, all diameters stainless steel KB-TZ, all diameters
uncracked concrete 700 120
cracked concrete 500 90
1 Mean values shown. Actual stiffness may vary considerably depending on concrete strength, loading and geometry of application.
h h
min
s
design
c
design
Min. 4-1/2"
Upper
Flute
(Valley)
Lower
Flute
(Ridge)
Min. 4-1/2"
Max. 1" Offset Typical
Minimum
No. 20 Gauge
Steel Deck
Min. 5/8" Typical
M
a
x
.

3
"
M
i
n
.

1
-
1
/
2
"
Min. 3000 psi Normal or Sand -
Lightweight Concrete
A
n
c
h
o
r

i
n

R
i
d
g
e
h
min
c
a, min
at s >
s
design
c
design
edge distance c
s
min
at c >
218 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006
Mechanical Anchoring Systems
4.3.4 Kwik Bolt TZ Expansion Anchor
Table 6 - Kwik Bolt TZ Carbon and Stainless Steel Allowable Static Tension (ASD),
Normal-Weight Uncracked Concrete, Condition B (lb)
1,2,3,4
Concrete Compressive Strength
2
Nominal Embedment f 'c= 2500 psi f 'c= 3000 psi f 'c= 4000 psi f 'c= 6000 psi
Anchor Depth h
ef
Carbon Stainless Carbon Stainless Carbon Stainless Carbon Stainless
Diameter (in.) Steel Steel Steel Steel Steel Steel Steel Steel
3/8 2 1168 1221 1279 1338 1477 1545 1809 1892
1/2
2 1576 1576 1726 1726 1993 1993 2441 2441
3-1/4 2561 2674 2805 2930 3239 3383 3967 4143
5/8
3-1/8 3078 3078 3372 3372 3893 3893 4768 4768
4 4246 4457 4651 4883 5371 5638 6578 6905
3/4
3-3/4 3844 4046 4211 4432 4863 5118 5956 6268
4-3/4 4959 5590 5432 6124 6272 7071 7682 8660
Table 7 - Kwik Bolt TZ Carbon and Stainless Steel Allowable Static Tension (ASD),
Normal-Weight Cracked Concrete, Condition B (lb)
1,2,3,4
Concrete Compressive Strength
2
Nominal Embedment f 'c= 2500 psi f 'c= 3000 psi f 'c= 4000 psi f 'c= 6000 psi
Anchor Depth h
ef
Carbon Stainless Carbon Stainless Carbon Stainless Carbon Stainless
Diameter (in.) Steel Steel Steel Steel Steel Steel Steel Steel
3/8 2 1054 1086 1155 1190 1333 1374 1633 1683
1/2
2 1116 1476 1223 1617 1412 1868 1729 2287
3-1/4 2282 2312 2500 2533 2886 2925 3535 3582
5/8
3-1/8 2180 2180 2388 2388 2758 2758 3377 3377
4 3157 2711 3458 2970 3994 3430 4891 4201
3/4
3-3/4 2866 3765 3139 4125 3625 4763 4440 5833
4-3/4 4085 4085 4475 4475 5168 5168 6329 6329
Allowable Stress Design
Design values for use with allowable stress design (working stress design) shall be established as follows: R
allow,ASD
=
R
d

where R
d
= R
k
represents the limiting design strength in tension ( N
n
) or shear ( V
n
) as calculated according to ACI 318 D.4.1.1 and D.4.1.2
Table 5 The value of shall be taken as follows:
Reference for strength
reduction factors including seismic excluding seismic
ACI 318 D.4.4 1.1 1.4
ACI 318 D.4.5 1.2 1.55
1 Values are for single anchors with no edge distance or spacing reduction. For other cases, calculation of R
d
as per ACI 318-05 and conversion to ASD in accordance with Table 5.
2 Values are for normal weight concrete. For sand-lightweight concrete, multiply values by 0.85. For all-lightweight concrete, multiply values by 0.75. See ACI 318-05 D.3.4.
3 Condition B applies where supplementary reinforcement in conformance with ACI 318-05 D.4.4 is not provided, or where pullout or pryout strength governs. For cases where the
presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used.
4 Allowable static tension loads for 2,500 psi are calculated by multiplying the concrete breakout strength N
b
by the strength reduction factor of 0.65 and dividing by an of 1.4
according to ICC ESR-1917 Section 4.2. N
b
is calculated as per ACI 318-05 D.5.2.2. This load may be adjusted for other concrete strengths according to ICC ESR-1917 Section
4.1.3 by using the following equation.
N
b,f
'
c
= N
b
f 'c
2500
1 Values are for single anchors with no edge distance or spacing reduction. For other cases, calculation of R
d
as per ACI 318-05 and conversion to ASD in accordance with Table 5.
2 Values are for normal weight concrete. For sand-lightweight concrete, multiply values by 0.85. For all-lightweight concrete, multiply values by 0.75. See ACI 318-05 D.3.4.
3 Condition B applies where supplementary reinforcement in conformance with ACI 318-05 D.4.4 is not provided, or where pullout or pryout strength governs. For cases where the
presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used.
4 Allowable static tension loads are calculated by multiplying the pullout strength N
p
by the strength reduction factor of 0.65 and dividing by an of 1.4 according to ICC ESR-
1917 Section 4.2. See Table 2 for N
p
. This load may be adjusted for other concrete strengths according to ICC ESR-1917 Section 4.1.3 by using the following equation.
N
p,cr,f
'
c
= N
p,cr
f 'c
2500
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006 219
Mechanical Anchoring Systems
Kwik Bolt TZ Expansion Anchor 4.3.4
Table 9 - Kwik Bolt TZ Carbon and Stainless Steel Allowable Seismic Tension (ASD),
Normal-Weight Cracked Concrete, Condition B (lb)
1,2,3,4
Concrete Compressive Strength
2
Nominal Embedment f 'c= 2500 psi f 'c= 3000 psi f 'c= 4000 psi f 'c= 6000 psi
Anchor Depth h
ef
Carbon Stainless Carbon Stainless Carbon Stainless Carbon Stainless
Diameter (in.) Steel Steel Steel Steel Steel Steel Steel Steel
3/8 2 1006 1037 1102 1136 1273 1312 1559 1607
1/2
2 1065 1212 1167 1328 1348 1533 1651 1878
3-1/4 2178 2207 2386 2418 2755 2792 3375 3419
5/8
3-1/8 2081 2081 2280 2280 2632 2632 3224 3224
4 3014 2588 3301 2835 3812 3274 4669 4010
3/4
3-3/4 2736 3594 2997 3937 3460 4546 4238 5568
4-3/4 3900 3900 4272 4272 4933 4933 6042 6042
1 Values are for single anchors with no edge distance or spacing
reduction due to concrete failure.
2 Allowable static shear loads are calculated by multiplying V
sa
by the
strength reduction factor of 0.65 and dividing by an of 1.4
according to ICC ESR-1917 Section 4.2. See Table 2 for V
sa
.
Table 8 - Kwik Bolt TZ Carbon and Stainless Steel
Allowable Static Shear (ASD), Steel (lb)
1,2
Nominal Allowable Steel Capacity, Static Shear
Anchor
Diameter Carbon Steel Stainless Steel
3/8 1669 2661
1/2 2974 3194
5/8 4901 5495
3/4 7396 9309
1 Values are for single anchors with no edge distance or spacing reduction
due to concrete failure.
2 Allowable seismic shear loads are calculated by multiplying V
s, seis
by the
strength reduction factor of 0.65, then multiply by 0.75 as per ACI 318-
05 D.3.3.3, and dividing by an of 1.1 according to ICC ESR-1917 Section
4.2. See Table 2 for V
s, seis
.
Table 10 - Kwik Bolt TZ Carbon and Stainless Steel
Allowable Seismic Shear (ASD), Steel (lb)
1,2
Nominal Allowable Steel Capacity, Seismic Shear
Anchor
Diameter Carbon Steel Stainless Steel
3/8 999 1252
1/2 2839 3049
5/8 4678 5245
3/4 6313 6477
1 Values are for single anchors with no edge distance or spacing reduction. For other cases, calculation of R
d
as per ACI 318-05 and conversion to ASD in accordance with Table 5.
2 Values are for normal weight concrete. For sand-lightweight concrete, multiply values by 0.85. For all-lightweight concrete, multiply values by 0.75. See ACI 318-05 D.3.4.
3 Condition B applies where supplementary reinforcement in conformance with ACI 318-05 D.4.4 is not provided, or where pullout or pryout strength governs. For cases where the
presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used.
4 Allowable seismic tension loads are calculated by multiplying the pullout strength N
p
by the strength reduction factor of 0.65, then multiplying by a 0.75 factor describe in ACI
318-05 D.3.3.3, and dividing by an of 1.1 according to ICC ESR-1917 Section 4.2. See Table 2 for N
p
. This load may be adjusted for other concrete strengths according to
ICC ESR-1917 Section 4.1.3 by using the following equation.
N
p,cr,f
'
c
= N
p,cr
f 'c
2500
220 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006
Mechanical Anchoring Systems
4.3.4 Kwik Bolt TZ Expansion Anchor
Table 12 Kwik Bolt TZ Length Identification System
Figure 4 Bolt Head with Length Identification Mark and Kwik Bolt TZ Head Notch Embossment
Length ID marking A B C D E F G H I J K L M N O P Q R S T U V W
on bolt head
Length of From 1
1
2 2 2
1
2 3 3
1
2 4 4
1
2 5 5
1
2 6 6
1
2 7 7
1
2 8 8
1
2 9 9
1
2 10 11 12 13 14 15
anchor, Up to but

anch
(in.) not 2 2
1
2 3 3
1
2 4 4
1
2 5 5
1
2 6 6
1
2 7 7
1
2 8 8
1
2 9 9
1
2 10 11 12 13 14 15 16
including
1 Pullout strength values N
p,deck
are for anchors installed in lightweight concrete having a minimum 2,500 psi compressive strength at the time of installation. See Table 3
ESR-1917. The values listed in Table 11 have been calculated assuming a minimum 3,000 psi concrete compressive strength. The pullout strength may be adjusted for
other lightweight concrete compressive strengths according to ICC ESR-1917 Section 4.1.3 using the following equation:
2 Minimum anchor spacing along the flute shall be the greater of 3.0 h
ef
or 1.5 times the flute width in accordance with ICC ESR-1917 Section 4.1.3.
3 Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction. See Figure 5 in ESR-1917.
4 Allowable seismic tension and shear loads are calculated by multiplying N
p,deck
and V
s,deck
by the strength reduction factor of 0.65, the seismic reduction factor of 0.75
according to ACI 318 D3.3.3, and then divided by an of 1.1 according to ICC ESR-1917 Section 4.2.
5 Allowable non-seismic tension and shear loads are calculated by multiplying N
p,deck
and V
s,deck
by the strength reduction factor of 0.65 and dividing by an of 1.4
according to ICC ESR-1917 Section 4.2.
Table 11 - Kwik Bolt TZ Carbon Steel Allowable Tension and Shear Loads (ASD),
Installed into the Underside of a Lightweight Concrete over Metal Deck Slab
1,2,3
Nominal Embedment Tension Tension Shear Shear
Anchor Depth h
ef
Seismic non-Seismic Seismic non-Seismic
Diameter (in.) (lb)
4
(lb)
5
(lb)
4
(lb)
5
3/8 2 709 743 944 989
1/2 2 709 743 1330 1393
1/2 3-1/4 1272 1333 2192 2296
5/8 3-1/8 971 1017 2039 2136
5/8 4 2255 2362 2677 2804
N
p,deck,f
'
c
= N
p,deck
(lb, psi)
f 'c
2500
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006 221
Mechanical Anchoring Systems
Kwik Bolt TZ Expansion Anchor 4.3.4
1. Hammer drill a hole to the same nominal
diameter as the Kwik Bolt TZ. The hole depth
must exceed the anchor embedment by at least
1/4 inch. The fixture may be used as a drilling
template to ensure proper anchor location.
2. Clean hole.
3. Drive the Kwik Bolt TZ into the hole using
a hammer. The anchor must be driven
until at least 4 threads are below the
surface of the fixture.
4. Tighten the nut to the recommended
installation torque.
4.3.4.4 Kwik Bolt TZ Anchor Installation Instructions
into normal-weight and lightweight concrete
222 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006
Mechanical Anchoring Systems
4.3.4 Kwik Bolt TZ Expansion Anchor
4.3.4.5 Kwik Bolt TZ Anchor Ordering Information
Item No. Description Length (in.) Thread Length (in.) Box Quantity
304581 KB-TZ 3/8x3 3 7/8 50
304582 KB-TZ 3/8x3-3/4 3-3/4 1-5/8 50
304583 KB-TZ 3/8x5 5 2-7/8 50
304584 KB-TZ 1/2x3-3/4 3-3/4 1-5/8 25
304585 KB-TZ 1/2x4-1/2 4-1/2 2-3/8 25
304586 KB-TZ 1/2x5-1/2 5-1/2 3-3/8 25
304587 KB-TZ 1/2x7 7 4-7/8 25
304588 KB-TZ 5/8x4-3/4 4-3/4 1-1/2 15
304589 KB-TZ 5/8x6 6 2-3/4 15
304590 KB-TZ 5/8x8-1/2 8-1/2 5-1/4 15
304591 KB-TZ 5/8x10 10 6-3/4 15
202880 KB-TZ 3/4x5-1/2 5 1/2 1-1/2 10
202881 KB-TZ 3/4x8 8 4 10
202882 KB-TZ 3/4x10 10 6 10
202883 KB-TZ SS304 3/8x3 3 7/8 50
202884 KB-TZ SS304 3/8x3-3/4 3-3/4 1-5/8 50
202885 KB-TZ SS304 3/8x5 5 2-7/8 50
202886 KB-TZ SS304 1/2x3-3/4 3-3/4 1-5/8 25
202887 KB-TZ SS304 1/2x4-1/2 4-1/2 2-3/8 25
202888 KB-TZ SS304 1/2x5-1/2 5-1/2 3-3/8 25
202889 KB-TZ SS304 1/2x7 7 4-7/8 25
202890 KB-TZ SS304 5/8x4-3/4 4-3/4 1-1/2 15
202891 KB-TZ SS304 5/8x6 6 2-3/4 15
202892 KB-TZ SS304 5/8x8-1/2 8-1/2 5-1/4 15
202893 KB-TZ SS304 5/8x10 10 6-3/4 15
202894 KB-TZ SS304 3/4x5-1/2 5-1/2 1-1/2 10
202895 KB-TZ SS304 3/4x8 8 4 10
202896 KB-TZ SS304 3/4x10 10 6 10
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006 223
Mechanical Anchoring Systems
Kwik Bolt TZ Expansion Anchor 4.3.4
Given:
(2) 1/2 in. KB-TZ anchors under
static tension load as shown.
h
ef
= 3.25 in.
Normal wt. concrete, f
c
= 3,000 psi
No supplementary reinforcing.
Assume uncracked concrete.
Condition B per ACI 318-05 D.4.4(c)
Calculate the allowable tension load
for this configuration.
Calculation per ACI 318-05 Appendix D and ICC ESR-1358. Code Ref. Reference
Step 1. Calculate steel strength of anchor in tension: N
s
= n * N
s
= 0.75 * 2 * 10,706 = 16,059 lb
D.5.1.2
D.4.4
Table 2
Step 2. Calculate concrete breakout strength of anchor in tension. See ESR-1917 for edge factor
cp,N
.
N
cbg
=
A
N c
(
ec,N
) (
ed,N,c,N
) (
cp,N
) N
b
D.5.2.1
ESR-1917
A
Nco
4.1.2
Step 2a. Verify minimum member thickness, spacing and edge distance: D.8 Table 2
h
min
= 6 in. 6 in. .
.
. ok Fig. 2
slope =
2.375 5.75
= 3.0
3.5 2.375
for c
min
= 4 in. y
1 -
y
2
= m ( x
1
- x
2
)
s
min
= 5.75 [(2.375 4.0) (3.0)] =0.875 < 2.375 in. < 6 in. .
.
. ok
Step 2b. Check: 1.5h
ef
= (1.5 ) (3.25) = 4.88 in. > c 3.0h
ef
= (3) (3.25) = 9.75 in. > s D.5.2.1 Table 2
Step 2c. Calculate A
Nco
and A
Nc
for the anchorage: A
Nco
= 9h
ef
2
= (9) (3.25)
2
= 95.1 in
2
A
Nc
= (1.5) (h
ef
+ c) (3) (h
ef
+ s) = [(1.5) (3.25) + 4] [(3 x 3.25) + 6] = 139.8 in
2
< 2A
Nco
.
.
. ok
D.5.2.1 Table 2
Step 2d. Calculate
ec,N
: e
N
' = O,
ec,N
= 1 D.5.2.4
Step 2e. Calculate N
b
: N
b
= k
cr
f '
c
( h
ef
)
1.5
= 17 3000 (3.25)
1.5
= 5,456 lb D.5.2.2 Table 2
Step 2f. Calculate modification factor for edge distance:
ed,N
= 0.7 + 0.3
4
= 0.95 D.5.2.5 Table 2
(1.5) (3.25)
Step 2g.
c,N
= 1.4 (uncracked concrete) D.5.2.6 Table 2
Step 2h. Calculate modification factor for splitting:

cp,N
=
c
a,min

1.5h
e f
check:
4
= 0.53 :
(1.5) (3.25)
= 0.65 0.53 < 0.65 .
.
.
1.5h
ef
controls
D.5.2.7 Table 2
c
ac
c
ac
7.5 7.5 c
ac
Step 2i. Calculate N
cbg
: N
cbg
=
139.8
(1) (0.95) (1.4) (5,456) (0.65) = 6,983 lb D.5.2.1 Table 2
95.1
Step 3. Check pullout strength: See ESR-1917 for adjustment for concrete strength
D.5.3.2
: N
pN,f
'
c
(1)
= 2
[
N
p, uncr
]
= 2
[
(5,515)
]
= 12,082 lb
Step 4. Controlling strength: N
cbg
= (0.65) (6,983) = 4,539 lb < N
s
.
.
. N
cbg
controls D.4.4(c) Table 2
Step 5. Convert value to ASD: T
allow
=
4,539
= 3,242 lb
1.4
- Table 5
6"
Table 2
ESR-1917
4.1.6
f '
c
2500
3000
2500
3.5, 2.375 2.375 controls
0.875
C
min
S
min
2.375, 5.75
s =6''
A
N
1.5h
ef
1.5h
ef c =4''
1.5h
ef
4.3.4.6 Kwik Bolt TZ Anchor Sample Calculations
( )
P R O F I S
PROFIS:
The Worlds Most Powerful
Anchor Design Software
Easy to Learn Start working in
just minutes
Fast and Powerful Produce detailed
designs quickly
Specify with Confidence The
largest number of approvals and
latest design codes
No charge.
Download now @ www.us.hilti.com
Firestop Systems
When it comes to Life Safety and building
code compliance, Hilti provides complete
solutions with a wide range of products
and unmatched technical support.
Firestop Systems Guides
- Through Penetrations
- Joint Penetrations
FACT Program
FS 411
BASIC Training
Engineering Judgements
Firestop Design Center online
@ www.us.hilti.com
Hilti Diaphragm
Deck Design
The Hilti Diaphragm Deck Design
Program allows designers to quickly
and accurately design roof deck and
composite floor deck diaphragms.
Ability to design with innovative
Hilti fasteners for frame and sidelap
connection
Creates easy to use load tables with
span ranges based on user input
Allows for different safety factors
depending on load type, building
code and field quality control
Direct link to Hilti website
MI Industrial
Pipe Support
Technical Guide
A guide to specifying the Hilti modular
pipe support system for medium to
heavy loads without welding.
MI System is the ideal solution for
pipes up to 24 in. diameter
Reliable fastenings without welds
Easily installed
Steel Decking
Technical Guide
For complete information on Hilti
fastening systems for the attachment
of steel roof and floor deck, refer to the
Hilti Steel Decking Technical Manual.
Resources
4 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I Product Technical Guide 2006 I Hilti (Canada) Corporation 1-800-363-4458 I www.ca.hilti.com
PAYMENT TERMS: Net 30 days from date of invoice. Customer agrees to pay all costs
incurred by Hilti in collecting delinquent amounts, if any, including
reasonable attorneys fees.
FREIGHT: All sales are F.O.B. Destination with transportation allowed via Hilti
designated mode. Additional charges may apply for expedited
shipments, special handling requirements, and orders below certain
dollar amounts. A fuel surcharge may apply depending on market
conditions.
CREDIT: All orders sold on credit are subject to Credit Department approval
RETURN POLICY: Products must be in saleable condition to qualify for return.
Saleable condition is defined as those unused items in original
packaging and in unbroken quantities. All returns are subject to Hilti
inspection and acceptance, and a 15% restocking charge. Proof of
purchase is required for all returned materials. Special orders and
discontinued items are not eligible for return credit. Dated materials
are not returnable 30 days beyond date of invoice.
WARRANTY: Hilti warrants that for a period of 12 months from the date it sells a
product it will, at its sole option and discretion, refund the purchase
price of , repair, or replace such product if it contains a defect in
material or workmanship. Absence of Hiltis receipt of a written
notification of such a defect within this 12-month period shall
constitute a waiver of all claims with regard to such product. The
warranty time periods for certain products are limited by the
warranty period in the literature that accompanies these products.
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO THE IMPLIED WARRANTIES OR MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE. Hilti shall in no
event be liable for, and Customer hereby agrees to indemnify Hilti
against all claims related to, special, direct, indirect, consequential,
or any damages arising out of or related to the sale, use, or inability
to use the product.
ACCEPTANCE OF ORDER: Acceptance is limited to the express terms contained herein, and
terms are subject to change by Hilti with reasonable notice to
Customer. Additional or different terms proposed by Customer are
deemed material and are objected to and rejected, but such
rejections shall not operate as a rejection of the offer unless it
contains variances in the terms of the description, quantity, price or
delivery schedule of the goods.
DOMESTIC ORIGIN: Any non-domestic Hilti product will be so identified on shipping
documents and invoices for federal government customers. All other
customers may obtain such information by written request for Hilti, Inc.,
Contract Compliance. P.O. Box 21148, Tulsa, Oklahoma 74121. Hilti
sales personnel are not authorized to warrant the country of origin of
Hilti products.
BUSINESS SIZE: Hilti is a large business.
PRICES: Prices are those stated on the order. Hilti does not maintain most
favored customer records, makes no representation with respect to
same, and rejects any price warranty terms proposed by Customer.
Hiltis published net price list is subject to change without notice.
CONSENT TO JURISDICTION: All transactions made pursuant hereto shall be deemed to have
been made and entered into in Tulsa, Oklahoma. Any and all
disputes arising directly or indirectly from such transactions shall be
resolved in the courts of the County of Tulsa, State of Oklahoma, to
the exclusion of any other court, and any resulting judgment may be
enforced by any court having jurisdiction of such an action. All
transactions shall be governed by and construed in accordance with
the laws of the State of Oklahoma.
INDEMNIFICATION: Customer hereby agrees to indemnify Hilti for any costs, including
attorneys fees, incurred by Hilti as a result, in whole or in part, of
any violation by Customer of any Federal, State or Local statute or
regulation, or of any nationally accepted standard. It shall be
Customers sole responsibility to comply with all applicable laws
and regulations regarding the handling, use, transportation, or
disposal of products upon taking possession of same.
AUTHORIZATION: HILTI SALES REPRESENTATIVES ARE NOT AUTHORIZED TO
MODIFY THESE TERMS AND CONDITIONS, WARRANT SPECIFIC
APPLICATIONS, OR EXECUTE CUSTOMER DOCUMENTS.
PAYMENT TERMS: Net 30 days from date of invoice. Customer
agrees to pay all costs incurred by Hilti in
collecting delinquent amounts, if any,
including reasonable attorneys fees.
FREIGHT: Sales are F.O.B. Destination Point with
transportation allowed via Hilti designated
mode. Additional charges may apply for
expedited delivery, special handling
requirements, and order under certain limits.
A fuel surcharge may apply depending on
market conditions.
CREDIT: All orders sold on credit are subject to
Credit Department approval.
RETURN POLICY: Product may be returned prepaid (unless
otherwise authorized) to Hilti provided:
i) it is returned by the original purchaser
ii) it is not dated product returned more than
30 days after the original delivery date
iii) it is not discontinued, clearance or special
order product
iv) it is unused, in original packaging and in
unbroken quantities.
Hilti will inspect product and, if the above
requirements are satisfied, will credit to
customer the original purchase price. A 15%
restocking fee may apply.
WARRANTY: Other than the manufacturers published
warranty, no warranties or conditions, express
or implied, written or oral, statutory or
otherwise are implied. Any and all conditions
and warranties implied by law or by the Sale
of Goods Act or any similar statutes of any
Province are hereby expressly waived.
TITLE TO PRODUCT: Title to product remains with Hilti until the
total purchase price of product is paid.
PRICES: Customer agrees to pay Hilti prices set out on
invoice. Customer agrees to pay taxes as
indicated on invoice unless Hilti receives
acceptable exemption certificates.
INDEMNIFICATION: Customer agrees to use product at own risk
and to indemnify Hilti against all liabilities,
including legal fees, to third parties arising out
of the use or possession thereof. Hilti shall in
no event be liable for special, incidental or
consequential damages.
CHANGES: Hilti sales personnel are not authorized to
modify these Terms and Conditions or modify
Customers credit terms. Terms are subject to
change by Hilti with reasonable notice to
Customer.
CASH SALES: Payment in full is due prior to goods being
released.
QUOTATIONS: All terms and conditions apply once customer
agrees to purchase product. Quotations on
special promotion products are only valid until
end of promotion period.
In The United Sates In Canada
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I Product Technical Guide 2006 I Hilti (Canada) Corporation 1-800-363-4458 I www.ca.hilti.com 5
Terms and Conditions
Hilti Online
Technical Library
Design Centers
Interactive Product Advisors
Full-line Product Catalog
Online Ordering
Maps to Hilti locations
Contact Us program to
answer your questions
P R O F I S
PROFIS:
The Worlds Most Powerful
Anchor Design Software
Easy to Learn Start working in
just minutes
Fast and Powerful Produce detailed
designs quickly
Specify with Confidence The
largest number of approvals and
latest design codes
No charge.
Download now @ www.us.hilti.com
Firestop Systems
When it comes to Life Safety and building
code compliance, Hilti provides complete
solutions with a wide range of products
and unmatched technical support.
Firestop Systems Guides
- Through Penetrations
- Joint Penetrations
FACT Program
FS 411
BASIC Training
Engineering Judgements
Firestop Design Center online
@ www.us.hilti.com
Hilti Diaphragm
Deck Design
The Hilti Diaphragm Deck Design
Program allows designers to quickly
and accurately design roof deck and
composite floor deck diaphragms.
Ability to design with innovative
Hilti fasteners for frame and sidelap
connection
Creates easy to use load tables with
span ranges based on user input
Allows for different safety factors
depending on load type, building
code and field quality control
Direct link to Hilti website
MI Industrial
Pipe Support
Technical Guide
A guide to specifying the Hilti modular
pipe support system for medium to
heavy loads without welding.
MI System is the ideal solution for
pipes up to 24 in. diameter
Reliable fastenings without welds
Easily installed
Steel Decking
Technical Guide
For complete information on Hilti
fastening systems for the attachment
of steel roof and floor deck, refer to the
Hilti Steel Decking Technical Manual.
Resources
4 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I Product Technical Guide 2006 I Hilti (Canada) Corporation 1-800-363-4458 I www.ca.hilti.com
PAYMENT TERMS: Net 30 days from date of invoice. Customer agrees to pay all costs
incurred by Hilti in collecting delinquent amounts, if any, including
reasonable attorneys fees.
FREIGHT: All sales are F.O.B. Destination with transportation allowed via Hilti
designated mode. Additional charges may apply for expedited
shipments, special handling requirements, and orders below certain
dollar amounts. A fuel surcharge may apply depending on market
conditions.
CREDIT: All orders sold on credit are subject to Credit Department approval
RETURN POLICY: Products must be in saleable condition to qualify for return.
Saleable condition is defined as those unused items in original
packaging and in unbroken quantities. All returns are subject to Hilti
inspection and acceptance, and a 15% restocking charge. Proof of
purchase is required for all returned materials. Special orders and
discontinued items are not eligible for return credit. Dated materials
are not returnable 30 days beyond date of invoice.
WARRANTY: Hilti warrants that for a period of 12 months from the date it sells a
product it will, at its sole option and discretion, refund the purchase
price of , repair, or replace such product if it contains a defect in
material or workmanship. Absence of Hiltis receipt of a written
notification of such a defect within this 12-month period shall
constitute a waiver of all claims with regard to such product. The
warranty time periods for certain products are limited by the
warranty period in the literature that accompanies these products.
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO THE IMPLIED WARRANTIES OR MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE. Hilti shall in no
event be liable for, and Customer hereby agrees to indemnify Hilti
against all claims related to, special, direct, indirect, consequential,
or any damages arising out of or related to the sale, use, or inability
to use the product.
ACCEPTANCE OF ORDER: Acceptance is limited to the express terms contained herein, and
terms are subject to change by Hilti with reasonable notice to
Customer. Additional or different terms proposed by Customer are
deemed material and are objected to and rejected, but such
rejections shall not operate as a rejection of the offer unless it
contains variances in the terms of the description, quantity, price or
delivery schedule of the goods.
DOMESTIC ORIGIN: Any non-domestic Hilti product will be so identified on shipping
documents and invoices for federal government customers. All other
customers may obtain such information by written request for Hilti, Inc.,
Contract Compliance. P.O. Box 21148, Tulsa, Oklahoma 74121. Hilti
sales personnel are not authorized to warrant the country of origin of
Hilti products.
BUSINESS SIZE: Hilti is a large business.
PRICES: Prices are those stated on the order. Hilti does not maintain most
favored customer records, makes no representation with respect to
same, and rejects any price warranty terms proposed by Customer.
Hiltis published net price list is subject to change without notice.
CONSENT TO JURISDICTION: All transactions made pursuant hereto shall be deemed to have
been made and entered into in Tulsa, Oklahoma. Any and all
disputes arising directly or indirectly from such transactions shall be
resolved in the courts of the County of Tulsa, State of Oklahoma, to
the exclusion of any other court, and any resulting judgment may be
enforced by any court having jurisdiction of such an action. All
transactions shall be governed by and construed in accordance with
the laws of the State of Oklahoma.
INDEMNIFICATION: Customer hereby agrees to indemnify Hilti for any costs, including
attorneys fees, incurred by Hilti as a result, in whole or in part, of
any violation by Customer of any Federal, State or Local statute or
regulation, or of any nationally accepted standard. It shall be
Customers sole responsibility to comply with all applicable laws
and regulations regarding the handling, use, transportation, or
disposal of products upon taking possession of same.
AUTHORIZATION: HILTI SALES REPRESENTATIVES ARE NOT AUTHORIZED TO
MODIFY THESE TERMS AND CONDITIONS, WARRANT SPECIFIC
APPLICATIONS, OR EXECUTE CUSTOMER DOCUMENTS.
PAYMENT TERMS: Net 30 days from date of invoice. Customer
agrees to pay all costs incurred by Hilti in
collecting delinquent amounts, if any,
including reasonable attorneys fees.
FREIGHT: Sales are F.O.B. Destination Point with
transportation allowed via Hilti designated
mode. Additional charges may apply for
expedited delivery, special handling
requirements, and order under certain limits.
A fuel surcharge may apply depending on
market conditions.
CREDIT: All orders sold on credit are subject to
Credit Department approval.
RETURN POLICY: Product may be returned prepaid (unless
otherwise authorized) to Hilti provided:
i) it is returned by the original purchaser
ii) it is not dated product returned more than
30 days after the original delivery date
iii) it is not discontinued, clearance or special
order product
iv) it is unused, in original packaging and in
unbroken quantities.
Hilti will inspect product and, if the above
requirements are satisfied, will credit to
customer the original purchase price. A 15%
restocking fee may apply.
WARRANTY: Other than the manufacturers published
warranty, no warranties or conditions, express
or implied, written or oral, statutory or
otherwise are implied. Any and all conditions
and warranties implied by law or by the Sale
of Goods Act or any similar statutes of any
Province are hereby expressly waived.
TITLE TO PRODUCT: Title to product remains with Hilti until the
total purchase price of product is paid.
PRICES: Customer agrees to pay Hilti prices set out on
invoice. Customer agrees to pay taxes as
indicated on invoice unless Hilti receives
acceptable exemption certificates.
INDEMNIFICATION: Customer agrees to use product at own risk
and to indemnify Hilti against all liabilities,
including legal fees, to third parties arising out
of the use or possession thereof. Hilti shall in
no event be liable for special, incidental or
consequential damages.
CHANGES: Hilti sales personnel are not authorized to
modify these Terms and Conditions or modify
Customers credit terms. Terms are subject to
change by Hilti with reasonable notice to
Customer.
CASH SALES: Payment in full is due prior to goods being
released.
QUOTATIONS: All terms and conditions apply once customer
agrees to purchase product. Quotations on
special promotion products are only valid until
end of promotion period.
In The United Sates In Canada
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I Product Technical Guide 2006 I Hilti (Canada) Corporation 1-800-363-4458 I www.ca.hilti.com 5
Terms and Conditions
Hilti Online
Technical Library
Design Centers
Interactive Product Advisors
Full-line Product Catalog
Online Ordering
Maps to Hilti locations
Contact Us program to
answer your questions

Вам также может понравиться