BTS power consumption Power consumption of various Flexi Multiradio BTS configurations See Table 36 Typical and maximum

power consumptions for Flexi Multiradio BTS configurations for Flexi Multiradio BTS power consumption values at 48 VDC input in 23C. For the FSME system module with FTIB transmission sub-module, add 110 W to the given values. For the alternative transmission sub-module FTLB, add 25 W in addition to the given values. Estimated typical power RF output consumption [W] at 48 VDC power per Configuration input in 23 C sector [W] 50% RF load 100% RF load 1+1+1 SIMO 1TX 2RX 2600MHz 60 931 1255 FSMF + 3-sector RF Module 1+1+1 SIMO 1TX 2RX 1800MHz 60 804 1034 FSMF + 3-sector RF Module 1+1+1 SIMO 1TX 2RX 1800MHz 80 809 1183 FSMF + 3-sector RF Module 1+1+1 SIMO 1TX 2RX 800MHz 60 794 1068 FSMF + 3-sector RF Module 1+1+1 MIMO 2TX 2RX 2600MHz FSMF + 3-sector RF Module 1+1+1 MIMO 2TX 2RX 1800MHz FSMF + 3-sector RF Module 1+1+1 MIMO 2TX 2RX 1800MHz FSMF + 3-sector RF Module 1+1+1 MIMO 2TX 2RX 800MHz FSMF + 3-sector RF Module

60

1737

2385

60

1483

1943

80

1493

2241

60

1463

2011

Configuration

RF output power per sector [W]

Estimated typical power consumption [W] at 48 VDC input in 23 C 50% RF load 100% RF load

1+1+1 MIMO 2TX 2RX 2600MHz FSMF + 2-sector RRH Module 1+1+1 MIMO 2TX 2RX 1800MHz FSMF + 2-sector RRH Module 1+1+1 MIMO 2TX 2RX 1800MHz FSMF + 2-sector RRH Module 1+1+1 MIMO 2TX 2RX 800MHz FSMF + 2-sector RRH Module

40

1076

1442

40

1034

1316

60

1277

1706

40

947

1244

Table 36: Typical and maximum power consumptions for Flexi Multiradio BTS configurations Basic typical conditions:

GbE Ethernet transport used room temperature 23C no MHA power feeding included no antenna tilting power feeding included

Flexi BTS site maximum power consumption consists of power feed to MHA + antenna tilt (3x30 W for the 3-sector RF Module). Up to 150 W higher power consumption can exist in extreme conditions and in BTS output power overdrive situations. In possible short circuit cases (for instance, antenna line), power consumption can momentarily be higher. The tolerance of the power consumption values is +/-10%. The values do not include the FCOA cabinet optional items; FCSA and FCFA power consumption. The estimated maximum heat load can be assumed to be the same as the power consumption values. For the power consumption of Flexi Outdoor Cabinet optional items fans FCSA, FCFA, and FCOS, see Table 37 Power consumption of Flexi Outdoor Cabinet fans FCFA, FCSA, and FCOS. FCFA FCSA FCOS 60 W clean 34 W at 23 C 32 W minimum

FCFA 100 W typical 180 W dirty

FCSA 94 W at 55 C

FCOS 43 W typical 58 W maximum

Table 37: Power consumption of Flexi Outdoor Cabinet fans FCFA, FCSA, and FCOS The total power consumption of Flexi Cabinet Site Support Module depends on which thirdparty configuration has been installed in the line terminal equipment space.