User Guide
Information in this document is subject to change without notice, and does not represent a commitment on the part of CYBELEC SA. The software described in this document is furnished under a license agreement or nondisclosure agreement. The software may be used or copied only in accordance with the terms of the agreement. It is against the law to copy the software on any medium except as specifically allowed in the license or nondisclosure agreement. Copyright CYBELEC SA. 1991 All rights reserved. Important: This notice explains normal and standard programming operations for the numerical control. In view of the fact that numerical controls can be equipped with configurable functions by the press manufacturer for his own specific purposes, please refer to the manufacturer-supplied complementary instructions regarding the programming of these functions.
is a registered trade mark of Autodesk Inc.. is a registred trademark of CYBELEC SA. is a registered trade mark of Xerox Corporation.
IBM , PC/AT , PC Network , Token Ring Network are registered trade marks of the International Business Machines Corporation. MS-DOS is a registered trade mark of Microsoft Corporation. is a registered trade mark of Microsoft Corporation. is a registered trade mark of Novell, Incorporated. is a registered trade mark of Microsoft Corporation.
The operator must be trained for working with the machine on which the numerical control is installed. Improper use of the numerical control can cause heavy damage on equipment and/or injuries to people. Modification of machine parameters can cause important material damage or lead to irregular product quality. The rear panel may only be removed by a qualified technician (danger of electrocution). Do not expose the numerical control to excessive humidity so as to avoid any risk of electrocution and any deterioration of the equipment. Make sure the numerical control is disconnected from the mains power before carrying out any cleaning. Do not use liquids based on alcohol or ammoniac. In case of malfunction of the numerical control, call a technician. Do not expose the numerical control to direct sun rays or any other heat source. Do not place the numerical control in the neighbourhood of magnetic equipment such as transformers, motors or devices which generate interference (welding machines, etc.) Replace fan filters at regular intervals so as to avoid overheating.
PAGE I
WARRANTY
CYBELEC does not warrant that its software products will function properly in every computer and programming environment. The limitations of use of a software product and its technical specifications are decided by CYBELEC only; CYBELEC solely is entitled to decide upon conformity and performance of a given software. The CYBELEC software does not compensate for incompatibilities in operating system revisions or versions. Running the CYBELEC software under various revisions or versions, or switching between different versions or revisions may result in loss or alteration of data.
LICENSE AGREEMENT
PAGE III
TERMINATION
This agreement shall automatically terminate upon any act of bankruptcy by or against licensee, upon any assignment for the benefit of creditors of the licensee, upon any attachment execution of judgement or process against licensee or its assets that substantially inhibits its ability to do business, or upon dissolution of licensee. CYBELEC has the right to terminate this agreement immediately, should the licensee violate the aforementioned conditions. Within 30 days of termination of this agreement for any reason, licensee shall at his option, either: return to CYBELEC or authorized dealer all existent copies of such software and related materials, or furnish to CYBELEC evidence satisfactory that the original and all copies of the software, in whole and in any form, have been destroyed.
LIMITATION OF LIABILITY
The foregoing warranty is instead of all other warranties, expressed or implied. Licensee further agrees that CYBELEC shall not be liable for any lost profits, lost savings, loss of use, or other incidental or consequential damages arising from the use or inability to use the software, or for any claim or demand against licensee by any other party. In no event shall CYBELEC be liable for consequential damages, even if CYBELEC has been advised of the possibility of such damages. CYBELEC does not warrant that the functions contained in the software will meet the licensee's requirement or that the operation of the software will be totally error free. Should the software prove defective, the licensee (and not CYBELEC or an authorized dealer or representative) will assume the entire cost of all necessary service, repair or correction. CYBELEC warrants the diskettes, EPROMS or other magnetic support or cassettes on which the programs are supplied to be free of defects in material and workmanship under normal use for a period of 90 days from the date of shipment to the licensee as evidenced by a copy of the packing slip.
PAGE IV
LICENSE AGREEMENT
LIMITATION OF REMEDIES
CYBELEC's entire liability and the licensee's exclusive remedy shall be as follows: The replacement of any diskettes or EPROMS or magnetic support media or cassettes not meeting CYBELEC's limited warranty and which materials are returned to CYBELEC or an authorized CYBELEC representative with a copy of the packing slip, or If CYBELEC or its representative is unable to deliver replacement diskettes, magnetic support media, EPROM or cassettes which are free of defects in materials or workmanship, the licensee may terminate this agreement under the terms and conditions herein mentioned, and the purchaser's money will be refunded.
GENERAL
The licensee acknowledges that he has read this agreement, understands it and agrees to be bound by its terms and conditions. The licensee agrees to hold CYBELEC harmless on all liability associated with licensee's breach of this agreement including, but not limited to, all reasonable attorney's fees and court costs, if any. This license agreement shall be governed by Swiss law; place of jurisdiction is Lausanne, Switzerland.
MAINTENANCE
CYBELEC will provide one year of software maintenance.The extent of maintenance, and response time for furnishing same, shall be at the sole discretion of CYBELEC.Maintenance shall normally include correction of errors in code, correction of errors in supporting documentation, update versions of the covered software which may be released by CYBELEC during the maintenance period. In no event shall CYBELEC be obliged to provide technical support in attempting to resolve problems or difficulties resulting from licensee's modification of the licensed software; any such modification by licensee is entirely at licensee's own risk.
LICENSE AGREEMENT
PAGE V
PAGE VI
LICENSE AGREEMENT
14.09.2004
V. 4.0
CONTENTS
SAFETY AND MAINTENANCE INSTRUCTIONS............................................................................I
INTRODUCTION..............................................................................................................................3
USING CYBACK ..............................................................................................................................7 Creating a link......................................................................................................................7 Data transmission................................................................................................................9 Backing Up data Restore data 9 10
PASSIVE MODE AND WAIT STATE...............................................................................................11 Transfer from the DNC ........................................................................................................12
OPERATOR INTERVENTION DURING DATA TRANSFER ...........................................................13 How to abort from the PC keyboard ....................................................................................13 How to abort from the DNC front panel ...............................................................................13
ANNEXES ........................................................................................................................................15 Connections.........................................................................................................................15 Loopback connector Connection for RS 232 cable Connection MPL PC 15 16 17
CYBACK_EN.DOC
CONTENTS
PAGE 1
PAGE 2
CONTENTS
INTRODUCTION
CYBACK is an ancillary software package running on IBM (or clone) PC. It enables you as the user to both BACKUP and RESTORE operational data held on any individual DNC 60, DNC 600, DNC 7000, DNC 70, DNC 30, DNC 50, DNC 20 or DNC 10 in your work environment using RS232/422 cables and connectors. Thus you are at liberty to economize on cabling requirements through the use of a central T-bar type switch to change from one destination DNC to another with minimum effort.
RESEAU RS232
At the moment, up to 10 such links are permitted. Note that CYBACK can BACKUP & RESTORE data for any version of DNC software. It is not necessary to know precisely what software is installed on a given machine before backing up its data. However, it is absolutely imperative that data backed up for a given DNC is always restored (when the occasion arises) to the very same machine from which it originated, or, alternatively, a machine running exactly the same version of software.
INTRODUCTION
PAGE 3
CYBACK facilitates this habitual good practice by identifying links by name strings. But its effective use depends equally upon the operator correctly assigning a link at backup/restore time, either using separate cables, or using the T-bar switch. Remember that the software cannot check for the right physical connection, nor identify the transmitting DNC. The PC is always the "master", whatever the nature of the link configuration is. The DNC is always the "slave". In other words, it is the operator of the PC who commands a transfer from its keyboard. The operator of the DNC is not able to carry out this manipulation, except for the "Wait state" where the transfer can be ordered from the DNC. It is nevertheless possible to cancel a current transfer, either on the PC or on the DNC (see paragraph Passive mode and wait state, page 11).
PAGE 4
GETTING STARTED
Copy the CYBACK_WIN.EXE file to the location you wish to have it on your hard disk. Eventually make a shortcut, which you will place on your "desk" in order to facilitate the starting of the program.
GETTING STARTED
PAGE 5
PAGE 6
USING CYBACK
CREATING A LINK
Click on "Tab" Setup.
Give a clear and unequivocal name to each link if you have defined several of them. If it concerns a fixed installation with several machines, you surely will opt for a switch with several positions on the RS 232 line. So you can define a switch position for each machine. Also select in which directory the data will be stored. The default values on your PC correspond exactly to the same default parameters of your DNC. Com port Specifies the communication port of the PC for the link. Default value: 1. Transmission speed in bits/second. 110, 150, 300, 600, 2400, 4800 or 9600. Default value: 4800.
Baud rate
USING CYBACK
PAGE 7
Parity
Transmission parity. 0 = None, no parity 1 = odd 2 = even Default value: NONE Allows the selection of different transmission protocols. 0 = DNC Xon (alike DNC). 1 = DNC Xor (alike DNC). 2 = BIP box, to transfer via a BIP box (32k bytes memory card) directly connected to the PC RS232 port. The data are compatible with the DNC in BIP mode. Box configuration: refer to the BIP manual. 3 = Puncher alike the DNC with 2 or 3 Default value: 0 Xon. If several links are in use via a central switch, then they can be labelled. Whole numbers between 0 and 10 permitted. Default value: 1. It is very important to change the position of the switch whenever a change from one link to another occurs. Otherwise there is a danger that a restore might be made to a certain DNC which is in fact intended for another one, the destination DNC's data being destroyed in the process.
Protocol
Selector pos.
Data bits
Number of data bits per character transmitted. 7 or 8. Default value: 8. Number of stop bits per character transmitted. 0 or 1. Default value: 1. Optional. DNC number to which the link is physically connected. This can be a serial number or a position number. This could be useful if, for example, you have to define several DNCs on the same physical link, and need to distinguish between them, reconnecting the cable from one to another. However, sharing a link in this way is not recommended, since the risk of erroneous RESTORES is increased.
Stop bits
DNC Nr
Make sure that the DNC(s) is(are) programmed with the same configuration.
PAGE 8
DATA TRANSMISSION
BACKING UP DATA
Click on "Tab" Backup DNC => PC.
Verify that the name of the connection (Data link) and the position of the possible selector really correspond to the connected machine. Select what you wish to back up. Press the "Ctrl" key + click to select several, non-adjacent products. Press the "Shift" key + click to select several adjacent products. Make sure that the DNC is in programming mode and that the stop is off. Then start the transfer.
USING CYBACK
PAGE 9
RESTORE DATA
Click on "Tab" Restore PC => DNC. The procedure is idential with backing up.
PAGE 10
PAGE 11
PAGE 12
You will then see a message in dark red at the foot of the screen confirming that the current BACKUP or RESTORE has been interrupted, and that the operation has not been completed. However, before making another attempt to BACKUP/RESTORE it is necessary to press on the relevant DNC.
If this is not done, then the message DNC BUSY will appear soon after the start of the next attempt.
PAGE 13
PAGE 14
ANNEXES
CONNECTIONS
LOOPBACK CONNECTOR
25 p DSUB 2 TD 3 RD 4 RTS 5 CTS 6 DSR 20 DTR
ANNEXES
PAGE 15
max 15 m
connexion sur capot mtallique Anschluss an Metallhlse connection on the metallic hood
DNC 25PF
CABLE 25PM
CABLE 9PF
PC 9PM
max 15 m
connexion sur capot mtallique Anschluss an Metallhlse connection on the metallic hood
PAGE 16
ANNEXES
CONNECTION MPL PC
BOITIER MPL 25PF CABLE 25PM CABLE 25PF PC 25PM
max 15 m
7 20 6 5 4 3 2 1
7 6 20 4 5 2 3 1
connexion sur capot mtallique Anschluss an Metallhlse connection on the metallic hood
ANNEXES