max
Where V
T0
=1.00V, r
T
=0.575m,
R
th
= Supplementary thermal impedance, see table below and
ff = Form factor, see table below.
Supplementary Thermal Impedance
Conduction Angle 6 phase (60) 3 phase (120) wave (180) d.c.
Square wave Double Side Cooled 0.0455 0.0393 0.0362 0.0319
Square wave Cathode Side Cooled 0.0753 0.0711 0.0687 0.0646
Sine wave Double Side Cooled 0.0397 0.0350 0.0313
Sine wave Cathode Side Cooled 0.0699 0.0677 0.0653
Form Factors
Conduction Angle 6 phase (60) 3 phase (120) wave (180) d.c.
Square wave 2.449 1.732 1.414 1
Sine wave 2.778 1.879 1.57
Rectifier Diode Types W1185LC300 to W1185LC450
Data Sheet. Types W1185LC300 to W1185LC450 Issue 3 Page 4 of 10 March, 2014
5.2 Calculating V
F
using ABCD Coefficients
The on-state characteristic I
F
vs. V
F
, on page 8 is represented in two ways;
(i) the well established V
T0
and r
T
tangent used for rating purposes and
(ii) a set of constants A, B, C, D, forming the coefficients of the representative equation for V
F
in
terms of I
F
given below:
( )
F F F F
I D I C I B A V + + + = ln
The constants, derived by curve fitting software, are given below for both hot and cold characteristics.
The resulting values for V
F
agree with the true device characteristic over a current range, which is limited
to that plotted.
160C Coefficients
A 0.5748073
B 0.04333389
C 0.464549710
-3
D 7.86742110
-3
Rectifier Diode Types W1185LC300 to W1185LC450
Data Sheet. Types W1185LC300 to W1185LC450 Issue 3 Page 5 of 10 March, 2014
5.3 D.C. Thermal Impedance Calculation
=
=
=
n p
p
t
p t
p
e r r
1
1
Where p = 1 to n, n is the number of terms in the series and:
t = Duration of heating pulse in seconds.
r
t
= Thermal resistance at time t.
r
p
= Amplitude of p
th
term.
p
= Time Constant of r
th
term.
The coefficients for this device are shown in the tables below:
D.C. Double Side Cooled
Term 1 2 3 4
r
p
0.017719 4.240610
-3
6.963810
-3
3.0436610
-3
p
0.708578 0.1435833 0.036152 2.130810
-3
D.C. Single Side Cooled
Term 1 2 3 4 5
r
p
0.04013 6.338810
-3
0.011408 6.027510
-3
7.209810
-4
p
4.07311 2.15774 0.19931 9.068910
-3
4.6634510
-4
6.0 Reverse recovery ratings
(i) Q
ra
is based on 50% I
rm
chord as shown in Fig. 1
Fig. 1
(ii) Q
rr
is based on a 150s integration time i.e.
=
s
rr rr
dt i Q
150
0
.
(iii)
2
1
t
t
Factor K =
Rectifier Diode Types W1185LC300 to W1185LC450
Data Sheet. Types W1185LC300 to W1185LC450 Issue 3 Page 6 of 10 March, 2014
Curves
Figure 1 Mean forward current vs. power dissipation Double side cooled
Figure 2 Mean forward current vs. power dissipation Single side cooled
W1185LC300-450
Issue 3
W1185LC300-450
Issue 3
Mean forward current (A) (Whole cycle averaged)
M
a
x
.
f
o
r
w
a
r
d
d
i
s
s
i
p
a
t
i
o
n
(
W
)
Mean forward current (A) (Whole cycle averaged)
M
a
x
.
f
o
r
w
a
r
d
d
i
s
s
i
p
a
t
i
o
n
(
W
)
Rectifier Diode Types W1185LC300 to W1185LC450
Data Sheet. Types W1185LC300 to W1185LC450 Issue 3 Page 7 of 10 March, 2014
Figure 3 Max. heatsink temperature vs. mean forward current Double side cooled
Figure 4 Max. heatsink temperature vs. mean forward current Single side cooled
W1185LC300-450
Issue 3
W1185LC300-450
Issue 3
Mean forward current (A) (Whole cycle averaged)
M
a
x
.
p
e
r
m
i
s
s
i
b
l
e
h
e
a
t
s
i
n
k
t
e
m
p
e
r
a
t
u
r
e
(
C
)
Mean forward current (A) (Whole cycle averaged)
M
a
x
.
p
e
r
m
i
s
s
i
b
l
e
h
e
a
t
s
i
n
k
t
e
m
p
e
r
a
t
u
r
e
(
C
)
Rectifier Diode Types W1185LC300 to W1185LC450
Data Sheet. Types W1185LC300 to W1185LC450 Issue 3 Page 8 of 10 March, 2014
Figure 5 Forward characteristics of limit device
Figure 6 Transient thermal impedance
W1185LC300-450
Issue 3
W1185LC300-450
Issue 3
Maximum instantaneous forward voltage (V)
I
n
s
t
a
n
t
a
n
e
o
u
s
f
o
r
w
a
r
d
c
u
r
r
e
n
t
(
A
)
Time (s)
T
h
e
r
m
a
l
i
m
p
e
d
a
n
c
e
(
C
/
W
)
160C
Rectifier Diode Types W1185LC300 to W1185LC450
Data Sheet. Types W1185LC300 to W1185LC450 Issue 3 Page 9 of 10 March, 2014
Figure 7 Maximum non-repetitive surge current at initial junction temperature 160C
W1185LC300-450
Issue 3
Duration of surge (ms) Duration of surge (cycles at 50Hz)
T
o
t
a
l
p
e
a
k
h
a
l
f
-
s
i
n
e
s
u
r
g
e
c
u
r
r
e
n
t
(
k
A
)
M
a
x
i
m
u
m
I
2
t
(
A
2
s
)
Rectifier Diode Types W1185LC300 to W1185LC450
Data Sheet. Types W1185LC300 to W1185LC450 Issue 3 Page 10 of 10 March, 2014
Outline Drawing & Ordering Information
ORDERING INFORMATION (Please quote 10 digit code as below)
W1185 LC 0
Fixed
Type Code
Fixed
Outline Code
Voltage code
V
RRM
/100
30-45
Fixed code
Order code: W1185LC450 4500V V
RRM
, 27mm clamp height capsule.
IXYS Semiconductor GmbH
Edisonstrae 15
D-68623 Lampertheim
Tel: +49 6206 503-0
Fax: +49 6206 503-627
E-mail: marcom@ixys.de
IXYS UK Westcode Ltd
Langley Park Way, Langley Park,
Chippenham, Wiltshire, SN15 1GE.
Tel: +44 (0)1249 444524
Fax: +44 (0)1249 659448
E-mail: sales@ixysuk.com
IXYS Corporation
1590 Buckeye Drive
Milpitas CA 95035-7418
Tel: +1 (408) 457 9000
Fax: +1 (408) 496 0670
E-mail: sales@ixys.net
www.ixysuk.com
www.ixys.com
IXYS Long Beach
IXYS Long Beach, Inc
2500 Mira Mar Ave, Long Beach
CA 90815
Tel: +1 (562) 296 6584
Fax: +1 (562) 296 6585
E-mail: service@ixyslongbeach.com
The information contained herein is confidential and is protected by Copyright. The information may not be used or disclosed
except with the written permission of and in the manner permitted by the proprietors IXYS UK Westcode Ltd.
In the interest of product improvement, IXYS UK Westcode Ltd reserves the right to change specifications at any time without
prior notice.
Devices with a suffix code (2-letter, 3-letter or letter/digit/letter combination) added to their generic code are not necessarily