GE Lighting

Helping achieve a greener future


ErP Legislation for HID Lamps

Towards a greener world


GE Lighting is fully committed to reducing carbon emissions. As a member of the European Lamp Companies Federation, we have helped develop the new energy-efficient regulations now being implemented, such as ErP.
The ErP - Energy related Product legislation (Commission Regulation (EC) No 245/2009) promotes energy efficiency and energyefficient products in terms of their environmental impact. This legislation is a directive of the European Parliament and council regarding eco-design requirements for lamps, ballasts and luminaires. Formerly known as the EuP, it affects the availability of such products in EU27 countries.* The regulation sets minimum performance and efficiency standards in the domestic and tertiary (office, industrial and street) lighting sectors for factors such as:

Phasing out
A number of popular lighting types will have to be phased out by 2017 including selected standard high-pressure sodium (including retrofit), high-pressure mercury, and standard performance metal halide. Products will not be available on the market in EU27 countries: only stock already in the distribution channel may continue to be sold.* Phasing out will happen in various stages starting 13th April 2012 (tertiary street lighting sector).
* Including Norway and Switzerland. ** In 2005, estimated annual energy consumption for products subject to this regulation within the EU was 200 (TWh) terawatt hours (corresponding to 80% CO2 emissions.) If no actions get taken, the estimated energy consumption in 2020 would be 260 TWh.

Efficacy Lumen maintenance Lamp survival Color rendering (Ra)

Reducing CO2 by 20%


ErP is one of three environmental protection directives implemented towards electrical and electronic products. (The others are WEEE recycling, and RoHS restriction of hazardous substances.) The ErP initiative plans to reduce CO2 emissions in the EU by an incredible 20%, saving an estimated 38 TWh, in 2020.**

The HID lamps affected


HID lamps subject to the ErP legislation are those with E27, E40 and PGZ12 bases (exemptions include directional light sources, reflectors, non white lights excluding HPS, lamps for non general purpose lighting, and UV sources). Non compliant lamps will not be able to bear the CE marking.

ErP legislative requirements


The following lamp types are required to have these minimum efficacies mentioned below by wattage.

April 13th 2012 High Pressure Sodium


High Pressure Sodium Lamps with Ra 60 and E27/E40 base
Lamp Wattage [W] W 45 45 < W 55 55 < W 75 75 < W 105 105 < W 155 155 < W 255 255 < W 605 Minimum Rated Lamp Efcacy Clear lamps [lm/W] 60 80 90 100 110 125 135 Diffuse lamps [lm/W] 60 70 80 95 105 115 130

April 13th 2015 Other Low Efficiency HID


High Pressure Mercury and Mixed Light Lamps with E27/E40 base
Lamp Wattage [W] W 40 40 < W 50 50 < W 70 70 < W 125 125 < W Minimum Rated Lamp Efcacy [lm/W] 50 55 65 70 75

High Pressure Sodium Lamps with Ra > 60 and E27/E40 base


Lamp Wattage [W] W 55 55 < W 75 75 < W 105 105 < W 155 155 < W 255 255 < W 405 Minimum Rated Lamp Efcacy Clear lamps [lm/W] 60 75 80 80 80 85 Diffuse lamps [lm/W] 60 70 75 75 75 75 Lamp Wattage [W] W 45 45 < W 55 55 < W 75 75 < W 105

HPS Mercury Retrot Lamps with E27/E40 base


Minimum Rated Lamp Efcacy Clear lamps [lm/W] 60 80 90 100 110 125 135 Diffuse lamps [lm/W] 60 70 80 95 105 115 130

105 < W 155 155 < W 255 255 < W 605

Metal Halide

(low performance)
Quartz Metal Halide lamps with Ra 80 and E27/E40 base
Lamp Wattage [W] W 55 55 < W 75 75 < W 105 105 < W 155 155 < W 255 255 < W 405 Minimum Rated Lamp Efcacy Clear lamps [lm/W] 60 75 80 80 80 85 Diffuse lamps [lm/W] 60 70 75 75 75 75

April 13th 2017 Metal Halide


Quartz Metal Halide and Standard Ceramic Metal Halide Lamps with E27/E40 base
Lamp Wattage [W] W 55 55 < W 75 75 < W 105 105 < W 155 155 < W 255 255 < W 405 Minimum Rated Lamp Efcacy Clear lamps [lm/W] 70 80 85 85 85 90 Diffuse lamps [lm/W] 65 75 80 80 80 85

Phasing out at GE the key stages


Stage 1 April 13th 2010
No performance related requirements applied to HID lamps, only performance ratings are required to be published on the internet

Stage 2 April 13th 2012


Low efficiency HPS and Quartz Metal Halide lamps will be phased out according to the defined efficiency levels

Stage 3 April 13th 2017


Quartz Metal Halide with wattages of 405 or below and standard Ceramic Metal Halide lamps will be phased out according to the defined efficiency levels

Intermediate stage April 13th 2015


High pressure Mercury and Mercury retrofit HPS lamps will be phased out according to the defined efficiency levels

Exemptions
Directional light sources, reflectors, non white lights (excluding HPS), lamps for non general purpose lighting, UV sources and HID lamps with bases other than E27, E40 or PGZ12*
*For a full list of exemptions please refer to the regulation No 245/2009

How and when are GE HID lamps affected


HID lamp (E27and E40 bases) High Pressure Sodium (HPS)
Lucalox Standard (50W and 150-400W), (std) Superlife, Start, Internal Ignitor (50W) Lucalox XO, XO Superlife, Standard (70-100W and 1000W), Internal Ignitor (70W)

2012

Implementation Year 2015

2017

Mercury, Mercury retrot HPS


Kolorlux Standard & Deluxe, Mixed Light, Lucalox E-Z Lux

Quartz Metal Halide


Multi-Vapor (250W U and 400W U Clear) Arcstream, Kolorarc, Multi-Vapor (250W VBU, 400W U Diffuse and 400W VBU) Sportlight, Multi-Vapor 1000W

Ceramic Metal Halide


ConstantColor CMH Standard (Elliptical & Tubular E27/E40) ConstantColor CMH StreetWise Available Phased out

How GE can help end users comply

GE has all the cost effective and reliable solutions needed to replace out-legislated lamps in the street lighting and industrial sectors.
As non-compliant lamps become obsolete, end users will need to switch to more energy efficient lamps usually through a simple relamping option. And as older technologies become obsolete, new installations will be required. Current installations using outdated technology will eventually need to be replaced by one of the following solutions:

CMH cost effective, Lucalox powerful white light outstanding performance The advanced technology of GEs
ConstantColor Ceramic Metal Halide lighting range meets the high standards of modern urban lighting. It offers unbeatable product reliability, efficiency and performance as a compact light source, providing bright, white light. Our CMH range has exceptionally long life and can easily be retrofitted into existing High Pressure Sodium luminaires with a one to one lamp replacement. Its ideal for safe and secure lighting for all outdoor spaces. GE also provides premium performance High Pressure Sodium lamps through our Lucalox XO ranges with significantly decreased maintenance costs. These ranges offer outstanding efficiency, extremely long life and reliability to meet increasing performance expectations on newly implemented regulations such as ErP.

Retrofitting Lamp only replacement Replacing lamp and ballast  Lamp and ballast replacement combination

Before

After

The range of GE alternatives


High Pressure Sodium
Lucalox Standard & Start tubular Phase out Replacement
Lucalox XO tubular 70W, 150W, 250W, 400W Benefit/Value
RETROFIT

1-1 lamp replacement Long life (up to 35000 hours) Higher lumen output up to 20% more Improved lumen maintenance Higher reliability

50W* 70W** 150W* 250W* 400W*


*Both Standard and Start wattage **Only Start wattage

Lucalox XO Superlife 50W, 70W, 150W, 250W, 400W CMH StreetWise 50W, 70W, 100W, 150W

Benefit/Value
RETROFIT

1-1 lamp replacement Very long life (up to 60000 hours) Higher lumen output up to 17% more Improved lumen maintenance Higher reliability

Benefit/Value
RETROFIT

1-1 lamp replacement possible White light Dimmable Higher efficiency up to 111 lm/W Up to 40% more efficient than standard HPS

Lucalox Standard & Start elliptical Phase out Replacement


Lucalox XO
RETROFIT

Benefit/Value
1-1 lamp replacement Long life (up to 35000 hours) Higher lumen output up to 20% more Improved lumen maintenance Higher reliability

50W 70W** 150W* 250W* 400W*


*Both Standard and Start wattage **Only Start wattage

50W, 70W, 150W, 250W, 400W

Lucalox XO Superlife 50W, 70W

RETROFIT

Benefit/Value
1-1 lamp replacement Very long life (up to 60000 hours) Higher lumen output up to 17% more Improved lumen maintenance Higher reliability

Lucalox Superlife tubular Phase out Replacement

Lucalox XO Superlife 70W, 100W, 150W, 250W, 400W

RETROFIT

Benefit/Value
1-1 lamp replacement Very long life (up to 60000 hours) Higher lumen output up to 17% more Improved lumen maintenance Higher reliability

50W 70W 100W 150W 250W 400W

Lucalox XO
RETROFIT

Benefit/Value
1-1 lamp replacement Long life (up to 35000 hours) High lumen output Improved lumen maintenance Higher reliability

50W, 70W, 100W, 150W, 250W, 400W

Lucalox Superlife elliptical Phase out Replacement


Lucalox XO Superlife Benefit/Value
RETROFIT

50W 70W 100W 150W 250W 400W

50W, 70W, 100W

1-1 lamp replacement Very long life (up to 60000 hours) Higher lumen output up to 17% more Improved lumen maintenance Higher reliability

Lucalox XO
RETROFIT

Benefit/Value
1-1 lamp replacement Long life (up to 35000 hours) High lumen output Improved lumen maintenance Higher reliability

50W, 70W, 100W, 150W, 250W, 400W

Product alternatives
ErP Affected Product
Product code Wattage [W] Product Description

Alternative 1
ErP Compliant Product Code ErP Compliant Description

Alternative 2
ErP Compliant Product Code ErP Compliant Description

Alternative 3
ErP Compliant Product Code ErP Compliant Description

High Pressure Sodium Lucalox Superlife


88558 88268 17899 35594 35586 35582 88557 88269 35589 35590 35591 50 70 100 150 250 400 50 70 150 250 400 LU50/85/MO/SBY/T/E27 LU70/90/MO/SBY/T/E27 LU100/100/MO/SBY/T/E40 LU150/100/SBY/T/E40 LU250/SBY/T/E40 LU400/SBY/T/E40 LU50/85/MO/SBY/D/E27 LU70/90/MO/SBY/D/E27 LU150/100/SBY/D/E40 LU250/SBY/D/E40 LU400/SBY/D/E40 --88258 88256 78737 78738 78739 97238 88257 --------LU70/90/XO/SBY/T12/E27 LU100/100/XO/SBY/T/E40 LU 150/XO/SBY/T/E40 LU 250/XO/SBY/T/E40 LU 400/XO/SBY/T/E40 LU50/85/XO/SBY/D/E27 LU70/90/XO/SBY/D/E27 -----------------------------------------------------------------------------------------------

High Pressure Sodium Lucalox Standard


88553 44244 22453 11678 88554 93766* 44245 44052 44057 50 150 250 400 50 100 150 250 400 LU50/85/MO/T/E27 LU150/100/E40 LU250/T/E40 LU400/T/E40 LU50/85/MO/D/E27 LU100/100/MO/D/E40 LU150/100/D/E40 LU250/D/E40 LU400/D/E40 93373 97241 93378 97240 45696 93379 93380 93381 93296 LU50/85/XO/T/E27 LU150/100/E40 LU250/XO/T/E40 LU400/T/E40 LU 50/85/XO/D/E27 LU100/100/XO/D/E40 LU150/100/XO/D/E40 LU250 XO D E40 LU400 XO D E40 77400 93377 78738 93269 97238 88255 ------CMH50/TT/UVC/730/E27 STREETWISE LU150/100/XO/T/E40 LU 250/XO/SBY/T/E40 LU400/XO/T/E40 LU50/85/XO/SBY/D/E27 LU100/100/XO/SBY/D/E40 --------77402 --78739 ------------CMH150/TT/UVC/730/E40 STREETWISE --LU 400/XO/SBY/T/E40 -----------

High Pressure Sodium Lucalox Internal Ignitor


88556 50 LU50/85/MO/D/I/E27 45696** LU 50/85/XO/D/E27 97238** LU50/85/XO/SBY/D/E27 -----

High Pressure Sodium Lucalox Start


96807 96815 96814 96808 96809 96810 96811 96813 70 70 70 150 150 250 250 400 LU70/90/D/I/27 GE START LU70/90/T12/27 GE START LU70/90/D/27 GE START LU150/100/T/40 GE START LU150/100/D/40 GE START LU250/T/40 GE START LU250/D/40 GE START LU400/T/40 GE START 46186 93375 45697 97241 93380 93378 93381 97240 LU 70/90/MO/D/I/E27 LU70/90/XO/T12/E27 LU 70/90/XO/D/E27 LU150/100/E40 LU150/100/XO/D/E40 LU250/XO/T/E40 LU250 XO D E40 LU400/T/E40 45697** 88258 88257 93377 --78738 --93269 LU 70/90/XO/D/E27 LU70/90/XO/SBY/T12/E27 LU70/90/XO/SBY/D/E27 LU150/100/XO/T/E40 --LU 250/XO/SBY/T/E40 --LU400/XO/T/E40 88257** 77401 --78737 ------78739 LU70/90/XO/SBY/D/E27 CMH70/TT/UVC/730/E27 STREETWISE --LU 150/XO/SBY/T/E40 ------LU 400/XO/SBY/T/E40

Quartz Metal Halide Multi-Vapor


44542 44543 43907 250 250 400 MVR250/U/E40 MVR250/C/U/E40 MVR400/U/E40 98777 98778 49860 MVR250/VBU/E40 MVR250/C/VBU/E40 MVR400/VBU/E40 -------------------------

*These lamps are currently non compliant, but we are working to upgrade them in the near future to meet the requirements of the regulation. **Non retrot solution Note: Standard 70W (Tubular & Elliptical), 100W (Tubular) & 70W Internal Ignitor lamps have been recently upgraded and are now compliant to the regulation.

www.gelighting.com/eu
and General Electric are both registered trademarks of the General Electric Company

GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a general guide, and we may change specications from time to time in the interest of product development, without prior notication or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on such data to the extent permitted by law. ErP HID brochure - October 2012.