Part #: 07005BM-B003
Tools Needed.
Phillips Screw Driver Flat Head Screw Driver (#1) 2.5mm L Shape allen wrench
Loosen the Phillips screws from the side of the Needle Case Cover.
Remove the 2.0mm set screws and get the Thread Guide (M) off the Needle Case Cover. Remove the Needle Case Cover.
2.5mm set screw from the Left side of the head 2.5mm set screw from the Left side of the head
Remove the 2.5mm set screws from the Left and Right side of the Needle Case as shown above. To remove the set screws from the Right side make sure the last needle to the left of the Needle Case Is above the Needle plate and to remove the set screws from the left side of the Needle Case make Sure the first needle to the Right is above the Needle Plate.
Push the shaft from the Right side of the Needle Case towards the left until the Take Up Lever That needs to be replace is out from the shaft. Look at the pictures below.
Fig 1
Remove the broken Take Up Lever as shown on fig 1
Fig 2
Replace with a new Take Up Lever as shown on fig 2
Shaf t
After the Take Up Lever is in place and aligned with the shaft , start pushing the shaft from the left side Of the Needle Case towards the Right until the shaft is flush with the wall of the Needle Case.
After the shaft is back in place proceed to tighten the 2.5mm set screws to secure the Shaft.
Mount the Needle Case Cover and the Thread Guide (M) back on to finish the Job.