Product data sheet

6ES7416-2XN05-0AB0
SIMATIC S7-400, CPU 416-2 CENTRAL PROCESSING UNIT WITH: 5.6 MB WORKING MEMORY, (2.8 MB CODE, 2.8 MB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE PROFIBUS DP

General information
Hardware product version Firmware version 04 V5.3

Engineering with
Programming package STEP7 V 5.3 SP2 or higher with HW update

CiR - Configuration in RUN


CiR synchronization time, basic load CiR synchronization time, time per I/O slave 100 ms 10 s

Supply voltage
24 V DC No ; Power supply via system power supply

Input current
from CPU, max. from backplane bus 5 V DC, typ. from backplane bus 5 V DC, max. from backplane bus 24 V DC, max. from interface 5 V DC, max. Not relevant for 400 series (300 series set) 0.9 A 1.1 A 300 mA ; 150 mA per DP interface 90 mA ; At each DP interface

Power losses
Power loss, typ. Power loss, max. 4.5 W 5W

6ES7416-2XN05-0AB0 Page 1/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014

Memory
Type of memory RAM

Work memory
integrated integrated (for program) integrated (for data) expandable 5.6 Mbyte 2.8 Mbyte 2.8 Mbyte No

Load memory
expandable FEPROM expandable FEPROM, max. integrated RAM, max. expandable RAM expandable RAM, max. Yes ; with Memory Card (FLASH) 64 Mbyte 1 Mbyte Yes ; with Memory Card (RAM) 64 Mbyte

Backup
present with battery without battery Yes Yes ; all data No

Battery Backup battery


Battery operation Backup current, typ. Backup current, max. Backup time, max. Feeding of external backup voltage to CPU Not relevant 125 A ; (up to 40 C) 550 A See reference manual, module data, Chapter 3.3 5 to 15 VDC

CPU processing times


for bit operations, typ. for word operations, typ. for fixed point arithmetic, typ. for floating point arithmetic, typ. 30 ns 30 ns 30 ns 90 ns

CPU-blocks DB
Number, max. Size, max. 10000 ; Number range: 1 to 16000 64 kbyte

FB
Number, max. Size, max. 5000 ; Number range: 0 to 7999 64 kbyte

FC
Number, max. 5000 ; Number range: 0 to 7999

6ES7416-2XN05-0AB0 Page 2/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014

Size, max.

64 kbyte

OB
Number, max. Size, max. Number of free cycle OBs Number of time alarm OBs Number of delay alarm OBs Number of time interrupt OBs Number of process alarm OBs Number of DPV1 alarm OBs Number isochronous mode OBs Number of multicomputing OBs Number of background OBs Number of startup OBs Number of asynchronous error OBs Number of synchronous error OBs see instruction list 64 kbyte 1 ; OB 1 8 ; OB 10-17 4 ; OB 20-23 9 ; OB 30-38 (shortest cycle that can be set = 500 s) 8 ; OB 40-47 3 ; OB 55-57 4 ; OB 61-64 1 ; OB 60 1 ; OB 90 3 ; OB 100-102 9 ; OB 80-88 2 ; OB 121, 122

Nesting depth
per priority class additional within an error OB 24 2

Counters, timers and their retentivity S7 counter


Number 2048

Retentivity
adjustable lower limit upper limit preset Yes 0 2047 Z 0 to Z 7

Counting range
lower limit upper limit 0 999

IEC counter
present Type Number Yes SFB Unlimited (limited only by RAM capacity)

S7 times
Number 2048

Retentivity
adjustable Yes

6ES7416-2XN05-0AB0 Page 3/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014

lower limit upper limit preset

0 2047 No times retentive

Time range
lower limit upper limit 10 ms 9990 s

IEC timer
present Type Number Yes SFB Unlimited (limited only by RAM capacity)

Data areas and their retentivity


retentive data area, total Total working and load memory (with backup battery)

Flag
Number, max. Retentivity available Retentivity preset Number of clock memories 16 kbyte ; Size of bit memory address area Yes MB 0 to MB 15 8 ; in 1 memory byte

Data blocks
Number, max. Size, max. 10000 ; Number range: 1 to 16000 64 kbyte

Local data
adjustable, max. preset 32 kbyte 16 kbyte

Address area I/O address area


Inputs Outputs 16 kbyte 16 kbyte

of which, distributed
MPI/DP interface, inputs MPI/DP interface, outputs DP interface, inputs DP interface, outputs 2 kbyte 2 kbyte 8 kbyte 8 kbyte

Process image
Inputs, adjustable Outputs, adjustable Inputs, default Outputs, default consistent data, max. 16 kbyte 16 kbyte 512 byte 512 byte 244 byte

6ES7416-2XN05-0AB0 Page 4/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014

Access to consistent data in process image

Yes

Subprocess images
Number of subprocess images, max. 15

Digital channels
Inputs Outputs Inputs, of which central Outputs, of which central 131072 131072 131072 131072

Analog channels
Inputs Outputs Inputs, of which central Outputs, of which central 8192 8192 8192 8192

Hardware configuration
Expansion devices, max. connectable OPs Multicomputing 21 63 Yes ; 4 CPUs max. (with UR1 or UR2)

Interface modules
Number of connectable IMs (total), max. Number of connectable IM 460s, max. Number of connectable IM 463s, max. 6 6 4 ; IM 463-2

Number of DP masters
integrated via IM 467 via CP Mixed mode IM + CP permitted 2 4 10 ; CP 443-5 Extended No ; IM 467 not suitable for use with CP 443-5 Ext. and CP443-1 EX4x, EX20, GX20 (in PNIO mode) 0 6

via interface module Number of pluggable S5 modules (via adapter capsule in central device), max.

Number of IO Controllers
integrated via CP 0 4 ; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller

Number of operable FMs and CPs (recommended)


FM CP, point-to-point Limited by number of slots and number of connections CP 440: Limited by number of slots; CP 441: limited by number of connections 14 ; Of which 10 CPs max. or IMs as DP master, 4 PN controller maximum

PROFIBUS and Ethernet CPs

6ES7416-2XN05-0AB0 Page 5/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014

Slots
Required slots 1

Time of day Clock


Hardware clock (real-time clock) battery-backed and synchronizable Resolution Deviation per day (buffered), max. Deviation per day (unbuffered) max. Yes Yes 1 ms 1.7 s ; Power off 8.6 s ; For power On

Operating hours counter


Number Number/Number range Range of values Granularity retentive 16 0 to 15 SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours 1 hour Yes

Clock synchronization
supported to MPI, master to MPI, slave to DP, master to DP, slave in AS, master in AS, slave on Ethernet via NTP to IF 964 DP Yes Yes Yes Yes Yes Yes Yes No ; via CP No

Time difference in system when synchronizing via


MPI, max. 200 ms

Digital outputs
integrated channels (DO) 0

Interfaces
Interfaces Number of USB interfaces Number of parallel interfaces Number of 20 mA interfaces (TTY) Number of RS 232 interfaces Number of RS 422 interfaces Number of other interfaces 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP 0 0 0 0 0 0

1st interface

6ES7416-2XN05-0AB0 Page 6/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014

Interface type Physics Isolated Power supply to interface (15 to 30 V DC), max. Number of connection resources

integrated RS 485 / PROFIBUS + MPI Yes 150 mA MPI: 44, DP: 32

Functionality
MPI DP master DP slave Yes Yes Yes

MPI
Number of connections 44 ; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 12 Mbit/s

Transmission rate, max.

Services
PG/OP communication Routing Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Yes Yes Yes Yes Yes Yes Yes

DP master
Number of connections, max. 32 ; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 12 Mbit/s 32

Transmission rate, max. Number of DP slaves, max.

Services
PG/OP communication Routing Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Equidistance mode support Isochronous mode SYNC/FREEZE Activation/deactivation of DP slaves Direct data exchange (slave-to-slave communication) Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes

6ES7416-2XN05-0AB0 Page 7/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014

DPV1

Yes

Address area
Inputs, max. Outputs, max. 2 kbyte 2 kbyte

User data per DP slave


User data per DP slave, max. Inputs, max. Outputs, max. Slots, max. per slot, max. 244 byte 244 byte 244 byte 244 128 byte

DP slave
Number of connections GSD file Transmission rate, max. Automatic baud rate search Address area, max. User data per address area, max. User data per address area, of which consistent, max. 32 http://support.automation.siemens.com/WW/view/de/113652 12 Mbit/s No 32 ; Virtual slots 32 byte 32 byte

Services
PG/OP communication Routing S7 routing Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Direct data exchange (slave-to-slave communication) DPV1 Yes ; with interface active Yes ; with interface active Yes ; with interface active No No Yes Yes Yes No No

Transfer memory
Inputs Outputs 244 byte 244 byte

2nd interface
Interface type Physics Isolated Power supply to interface (15 to 30 V DC), max. Number of connection resources integrated RS 485 / PROFIBUS Yes 150 mA 32

6ES7416-2XN05-0AB0 Page 8/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014

Functionality
DP master DP slave Yes Yes

DP master
Number of connections, max. Transmission rate, max. Number of DP slaves, max. 32 12 Mbit/s 125

Services
PG/OP communication Routing Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Equidistance mode support Isochronous mode SYNC/FREEZE Activation/deactivation of DP slaves Direct data exchange (slave-to-slave communication) DPV1 Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Address area
Inputs, max. Outputs, max. 8 kbyte 8 kbyte

User data per DP slave


User data per DP slave, max. Inputs, max. Outputs, max. Slots, max. per slot, max. 244 byte 244 byte 244 byte 244 128 byte

DP slave
Number of connections GSD file Transmission rate, max. Address area, max. User data per address area, max. User data per address area, of which consistent, max. 32 http://support.automation.siemens.com/WW/view/de/113652 12 Mbit/s 32 32 byte 32 byte

Services

6ES7416-2XN05-0AB0 Page 9/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014

Routing

Yes

Transfer memory
Inputs Outputs 244 byte 244 byte

Isochronous mode
Isochronous operation (application synchronized up to terminal) Number of DP masters with isochronous mode User data per isochronous slave, max. equidistance shortest clock pulse max. cycle Yes ; For PROFIBUS only

2 244 byte Yes 1 ms ; 0.5 ms without use of SFC 126, 127 32 ms

Communication functions
PG/OP communication Number of connectable OPs without message processing Number of connectable OPs with message processing Data record routing Yes 63 63 ; When using alarm_S and alarm_D Yes

Global data communication


supported Number of GD loops, max. Number of GD packets, transmitter, max. Number of GD packets, receiver, max. Size of GD packets, max. Size of GD packet (of which consistent), max. Yes 16 16 32 54 byte 1 variable

S7 basic communication
supported User data per job, max. User data per job (of which consistent), max. Yes 76 byte 1 variable

S7 communication
supported as server as client User data per job, max. User data per job (of which consistent), max. Yes Yes Yes 64 kbyte 462 byte ; 1 variable

S5-compatible communication
supported Yes ; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 8 kbyte 240 byte

User data per job, max. User data per job (of which consistent), max.

6ES7416-2XN05-0AB0 Page 10/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014

Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.

64/64

Standard communication (FMS)


supported Yes ; Via CP and loadable FB

Open IE communication
ISO-on-TCP (RFC1006) Data length, max. Via CP 443-1 and loadable FB 1452 bytes via CP 443-1 Adv.

Web server
supported No

Number of connections
overall usable for PG communication reserved for PG communication Adjustable for PG communication, max. usable for OP communication reserved for OP communication adjustable for OP communication, max. usable for S7 basic communication Reserved for S7 basic communication adjustable for S7 basic communication, max. usable for S7 communication reserved for S7 communication Adjustable for S7 communication, max. usable for routing Reserved for routing adjustable for routing, max. 0 0 0 0 0 0 1 0 1 0 64

S7 message functions
Number of login stations for message functions, max. 63 ; Max. 63 with ALARM_S and ALARM_D (OPs); max. 12 with ALARM_8 and ALARM_P (e.g. WinCC) Yes Yes Yes Yes 1000 ; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks Yes 4000

Symbol-related messages SCAN procedure Block related messages Process diagnostic messages simultaneously active Alarm-S blocks, max.

Alarm 8-blocks Number of instances for alarm 8 and S7 communication blocks, max. preset, max. Process control messages

600 Yes

6ES7416-2XN05-0AB0 Page 11/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014

Number of archives that can log on simultaneously (SFB 37 AR_SEND)

32

Number of messages
overall, max. in 100 ms grid, max. in 500 ms grid, max. in 1000 ms grid, max. 1024 128 512 1024

Number of additional values


with 100 ms grid, max. with 500, 1000 ms grid, max. 1 10

Test commissioning functions


Status block Single step Number of breakpoints Yes ; Up to 2 simultaneously Yes 4

Status/control
Status/control variable Variables Number of variables, max. Yes ; Up to 16 variable tables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters 70 ; Status/control

Forcing
Forcing Force, variables Number of variables, max. Yes Inputs, outputs, bit memories, peripheral inputs, peripheral outputs 512

Diagnostic buffer
present Number of entries, max. adjustable preset Yes 3200 Yes 120

EMC Emission of radio interference acc. to EN 55 011


Limit class A, for use in industrial areas Limit class B, for use in residential areas Yes No

Configuration Configuration software


STEP 7 Yes

programming
Command set Nesting levels Access to consistent data in process image System functions (SFC) see instruction list 7 Yes see instruction list

6ES7416-2XN05-0AB0 Page 12/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014

System function blocks (SFB)

see instruction list

Programming language
LAD FBD STL SCL CFC GRAPH HiGraph Yes Yes Yes Yes Yes Yes Yes

Number of simultaneously active SFCs


DPSYC_FR D_ACT_DP RD_REC WR_REC WR_PARM PARM_MOD WR_DPARM DPNRM_DG RDSYSST DP_TOPOL 2 8 8 8 8 1 2 8 8 1

Number of simultaneously active SFBs


RD_REC WR_REC 8 8

Know-how protection
User program protection/password protection Yes

Dimensions
Width Height Depth 25 mm 290 mm 219 mm

Weights
Weight, approx. Status 0.7 kg Mar 29, 2014

6ES7416-2XN05-0AB0 Page 13/ 13

04/04/2014

subject to modifications Copyright Siemens AG 2014