General information
Hardware product version Firmware version 04 V5.3
Engineering with
Programming package STEP7 V 5.3 SP2 or higher with HW update
Supply voltage
24 V DC No ; Power supply via system power supply
Input current
from CPU, max. from backplane bus 5 V DC, typ. from backplane bus 5 V DC, max. from backplane bus 24 V DC, max. from interface 5 V DC, max. Not relevant for 400 series (300 series set) 0.9 A 1.1 A 300 mA ; 150 mA per DP interface 90 mA ; At each DP interface
Power losses
Power loss, typ. Power loss, max. 4.5 W 5W
6ES7416-2XN05-0AB0 Page 1/ 13
04/04/2014
Memory
Type of memory RAM
Work memory
integrated integrated (for program) integrated (for data) expandable 5.6 Mbyte 2.8 Mbyte 2.8 Mbyte No
Load memory
expandable FEPROM expandable FEPROM, max. integrated RAM, max. expandable RAM expandable RAM, max. Yes ; with Memory Card (FLASH) 64 Mbyte 1 Mbyte Yes ; with Memory Card (RAM) 64 Mbyte
Backup
present with battery without battery Yes Yes ; all data No
CPU-blocks DB
Number, max. Size, max. 10000 ; Number range: 1 to 16000 64 kbyte
FB
Number, max. Size, max. 5000 ; Number range: 0 to 7999 64 kbyte
FC
Number, max. 5000 ; Number range: 0 to 7999
6ES7416-2XN05-0AB0 Page 2/ 13
04/04/2014
Size, max.
64 kbyte
OB
Number, max. Size, max. Number of free cycle OBs Number of time alarm OBs Number of delay alarm OBs Number of time interrupt OBs Number of process alarm OBs Number of DPV1 alarm OBs Number isochronous mode OBs Number of multicomputing OBs Number of background OBs Number of startup OBs Number of asynchronous error OBs Number of synchronous error OBs see instruction list 64 kbyte 1 ; OB 1 8 ; OB 10-17 4 ; OB 20-23 9 ; OB 30-38 (shortest cycle that can be set = 500 s) 8 ; OB 40-47 3 ; OB 55-57 4 ; OB 61-64 1 ; OB 60 1 ; OB 90 3 ; OB 100-102 9 ; OB 80-88 2 ; OB 121, 122
Nesting depth
per priority class additional within an error OB 24 2
Retentivity
adjustable lower limit upper limit preset Yes 0 2047 Z 0 to Z 7
Counting range
lower limit upper limit 0 999
IEC counter
present Type Number Yes SFB Unlimited (limited only by RAM capacity)
S7 times
Number 2048
Retentivity
adjustable Yes
6ES7416-2XN05-0AB0 Page 3/ 13
04/04/2014
Time range
lower limit upper limit 10 ms 9990 s
IEC timer
present Type Number Yes SFB Unlimited (limited only by RAM capacity)
Flag
Number, max. Retentivity available Retentivity preset Number of clock memories 16 kbyte ; Size of bit memory address area Yes MB 0 to MB 15 8 ; in 1 memory byte
Data blocks
Number, max. Size, max. 10000 ; Number range: 1 to 16000 64 kbyte
Local data
adjustable, max. preset 32 kbyte 16 kbyte
of which, distributed
MPI/DP interface, inputs MPI/DP interface, outputs DP interface, inputs DP interface, outputs 2 kbyte 2 kbyte 8 kbyte 8 kbyte
Process image
Inputs, adjustable Outputs, adjustable Inputs, default Outputs, default consistent data, max. 16 kbyte 16 kbyte 512 byte 512 byte 244 byte
6ES7416-2XN05-0AB0 Page 4/ 13
04/04/2014
Yes
Subprocess images
Number of subprocess images, max. 15
Digital channels
Inputs Outputs Inputs, of which central Outputs, of which central 131072 131072 131072 131072
Analog channels
Inputs Outputs Inputs, of which central Outputs, of which central 8192 8192 8192 8192
Hardware configuration
Expansion devices, max. connectable OPs Multicomputing 21 63 Yes ; 4 CPUs max. (with UR1 or UR2)
Interface modules
Number of connectable IMs (total), max. Number of connectable IM 460s, max. Number of connectable IM 463s, max. 6 6 4 ; IM 463-2
Number of DP masters
integrated via IM 467 via CP Mixed mode IM + CP permitted 2 4 10 ; CP 443-5 Extended No ; IM 467 not suitable for use with CP 443-5 Ext. and CP443-1 EX4x, EX20, GX20 (in PNIO mode) 0 6
via interface module Number of pluggable S5 modules (via adapter capsule in central device), max.
Number of IO Controllers
integrated via CP 0 4 ; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller
6ES7416-2XN05-0AB0 Page 5/ 13
04/04/2014
Slots
Required slots 1
Clock synchronization
supported to MPI, master to MPI, slave to DP, master to DP, slave in AS, master in AS, slave on Ethernet via NTP to IF 964 DP Yes Yes Yes Yes Yes Yes Yes No ; via CP No
Digital outputs
integrated channels (DO) 0
Interfaces
Interfaces Number of USB interfaces Number of parallel interfaces Number of 20 mA interfaces (TTY) Number of RS 232 interfaces Number of RS 422 interfaces Number of other interfaces 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP 0 0 0 0 0 0
1st interface
6ES7416-2XN05-0AB0 Page 6/ 13
04/04/2014
Interface type Physics Isolated Power supply to interface (15 to 30 V DC), max. Number of connection resources
Functionality
MPI DP master DP slave Yes Yes Yes
MPI
Number of connections 44 ; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 12 Mbit/s
Services
PG/OP communication Routing Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Yes Yes Yes Yes Yes Yes Yes
DP master
Number of connections, max. 32 ; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 12 Mbit/s 32
Services
PG/OP communication Routing Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Equidistance mode support Isochronous mode SYNC/FREEZE Activation/deactivation of DP slaves Direct data exchange (slave-to-slave communication) Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes
6ES7416-2XN05-0AB0 Page 7/ 13
04/04/2014
DPV1
Yes
Address area
Inputs, max. Outputs, max. 2 kbyte 2 kbyte
DP slave
Number of connections GSD file Transmission rate, max. Automatic baud rate search Address area, max. User data per address area, max. User data per address area, of which consistent, max. 32 http://support.automation.siemens.com/WW/view/de/113652 12 Mbit/s No 32 ; Virtual slots 32 byte 32 byte
Services
PG/OP communication Routing S7 routing Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Direct data exchange (slave-to-slave communication) DPV1 Yes ; with interface active Yes ; with interface active Yes ; with interface active No No Yes Yes Yes No No
Transfer memory
Inputs Outputs 244 byte 244 byte
2nd interface
Interface type Physics Isolated Power supply to interface (15 to 30 V DC), max. Number of connection resources integrated RS 485 / PROFIBUS Yes 150 mA 32
6ES7416-2XN05-0AB0 Page 8/ 13
04/04/2014
Functionality
DP master DP slave Yes Yes
DP master
Number of connections, max. Transmission rate, max. Number of DP slaves, max. 32 12 Mbit/s 125
Services
PG/OP communication Routing Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Equidistance mode support Isochronous mode SYNC/FREEZE Activation/deactivation of DP slaves Direct data exchange (slave-to-slave communication) DPV1 Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Address area
Inputs, max. Outputs, max. 8 kbyte 8 kbyte
DP slave
Number of connections GSD file Transmission rate, max. Address area, max. User data per address area, max. User data per address area, of which consistent, max. 32 http://support.automation.siemens.com/WW/view/de/113652 12 Mbit/s 32 32 byte 32 byte
Services
6ES7416-2XN05-0AB0 Page 9/ 13
04/04/2014
Routing
Yes
Transfer memory
Inputs Outputs 244 byte 244 byte
Isochronous mode
Isochronous operation (application synchronized up to terminal) Number of DP masters with isochronous mode User data per isochronous slave, max. equidistance shortest clock pulse max. cycle Yes ; For PROFIBUS only
Communication functions
PG/OP communication Number of connectable OPs without message processing Number of connectable OPs with message processing Data record routing Yes 63 63 ; When using alarm_S and alarm_D Yes
S7 basic communication
supported User data per job, max. User data per job (of which consistent), max. Yes 76 byte 1 variable
S7 communication
supported as server as client User data per job, max. User data per job (of which consistent), max. Yes Yes Yes 64 kbyte 462 byte ; 1 variable
S5-compatible communication
supported Yes ; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 8 kbyte 240 byte
User data per job, max. User data per job (of which consistent), max.
04/04/2014
64/64
Open IE communication
ISO-on-TCP (RFC1006) Data length, max. Via CP 443-1 and loadable FB 1452 bytes via CP 443-1 Adv.
Web server
supported No
Number of connections
overall usable for PG communication reserved for PG communication Adjustable for PG communication, max. usable for OP communication reserved for OP communication adjustable for OP communication, max. usable for S7 basic communication Reserved for S7 basic communication adjustable for S7 basic communication, max. usable for S7 communication reserved for S7 communication Adjustable for S7 communication, max. usable for routing Reserved for routing adjustable for routing, max. 0 0 0 0 0 0 1 0 1 0 64
S7 message functions
Number of login stations for message functions, max. 63 ; Max. 63 with ALARM_S and ALARM_D (OPs); max. 12 with ALARM_8 and ALARM_P (e.g. WinCC) Yes Yes Yes Yes 1000 ; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks Yes 4000
Symbol-related messages SCAN procedure Block related messages Process diagnostic messages simultaneously active Alarm-S blocks, max.
Alarm 8-blocks Number of instances for alarm 8 and S7 communication blocks, max. preset, max. Process control messages
600 Yes
04/04/2014
32
Number of messages
overall, max. in 100 ms grid, max. in 500 ms grid, max. in 1000 ms grid, max. 1024 128 512 1024
Status/control
Status/control variable Variables Number of variables, max. Yes ; Up to 16 variable tables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters 70 ; Status/control
Forcing
Forcing Force, variables Number of variables, max. Yes Inputs, outputs, bit memories, peripheral inputs, peripheral outputs 512
Diagnostic buffer
present Number of entries, max. adjustable preset Yes 3200 Yes 120
programming
Command set Nesting levels Access to consistent data in process image System functions (SFC) see instruction list 7 Yes see instruction list
04/04/2014
Programming language
LAD FBD STL SCL CFC GRAPH HiGraph Yes Yes Yes Yes Yes Yes Yes
Know-how protection
User program protection/password protection Yes
Dimensions
Width Height Depth 25 mm 290 mm 219 mm
Weights
Weight, approx. Status 0.7 kg Mar 29, 2014