Panasonic Industrial Company

Air Conditioning Department


2K20S3R236A-6B
Application Ref. Charge Limit (C/H) (C) Evap. Temp. Range (C/H) (C) Specification Number Cooling (C) / Heating (H) 33.5 oz. 950 g 38.8 oz. 1100 g 5F to 53.6F -15oC to 12oC 14F to 53.6F -10oC to 12oC SC-52170557-A

2K20S3R236A-6B
208/230 V, 60 Hz R-22

Rated Performance @230V1


Capacity Motor Input Current E.E.R. 13,810 Btu/hr 1,280 Watts 5.7 Amperes 10.79 Btu/hr/ W

Compressor Data
Pump Type Displacement Oil Oil Charge (Precharged) Net Weight Rotary 19.6 cc/rev ATMOS M60 or equivalent 13.9 fl. oz. 410 cc 35.3 lb 16.0 kg

Motor Data
Motor Type Permanent Split Capacitor Locked Rotor Amperes 33 A at 240 V Winding Resistance Main: 2.391W, Aux: 1.423W Max. Continuous Current2

Maximum Operating Conditions


Condensing Temp. Return Gas Temp. Discharge Gas Temp. Motor Wire Temp. 149F 95F 239F 266F 65C 35C 115C 130C

Performance Data @230V Based on: Return gas Temp. Liquid sub-cooling Ambient
100F 37.8oC EVAP. TEMP. 35 F 1.7oC Btu/hr Watts Amperes Btu/hr Watts Amperes Btu/hr Watts Amperes 13615 875 4.0 16600 875 4.0 20070 835 3.8 12840 1005 4.6 15680 1010 4.6 19005 995 4.5
2

95F 15F 95F


COND. TEMP. 120F 48.9oC 12065 1130 5.1 14750 1145 5.1 17910 1145 5.1

35.0C 8.3C 35.0C


130F 54.4oC 11295 1250 5.6 13810 1280 5.7 16785 1295 5.8 140F 60oC 10530 1360 6.1 12855 1405 6.3 15635 1435 6.4

Electrical Components
Overload Protector Texas Instrument part # Run Capacitor
1

7100500 or 7100501 MRA 98908 or MRA 98848 35 or 40 F/330 VAC

110F 43.3oC

Evaporating Temp. Condensing Temp. Return Gas Temp. Liquid Temp. Ambient Temp.

Rated @ ASHRAE/T Conditions


45F 130F 95F 115F 95F

7.2C 54.4C 35.0C 46.1C 35.0C

45 F 7.2oC

55 F 12.8oC

UL file no.: SA4615; CSA file no.: LR46130, LR51349, LR66348, LR76919, LR95789, LR109092

Contact Panasonic for value.

BTU 14,000

2K20S3R236A-6B
208/230 V, 60 Hz R-22 WIRING DIAGRAM

BTU 14,000
COMPRESSOR ACCESSORIES
This document sets forth certain operational parameters and conditions for operation of this product. If this product is operated outside of the parameters and conditions stated herein, buyer assumes sole and full responsibility and shall indemnify seller with respect to all product failures, and all consequences thereof. Operation of the product outside of the parameters and conditions specified herein shall serve to invalidate all seller warranties, if any, with respect to the product. Use this document as reference only. For specifications, please contact Panasonics engineering department.

(10.87) (9.76)

276 248

LA LT

Acce ssorie s 1 2 3 4 5 Gasket-Terminal Cover Spring-OLP hold dow n Terminal Cover Gasket-Nut Nut-Terminal Cover Grommet

Part Numbe r 7070620U 7041200 7070219U 7070621U 7080300 7070815

COMPRESSOR MOUNTING