SECTION 10500

METAL LOCKERS
1. PART 1 - GENERAL
1.01 SECTION INCLUDES
A.

Locker units with hinged doors and the related Work


as indicated on Drawings and specified herein.

1.02 REFERENCES
A.

ASTM - American Society for Testing and Materials


ASTM A 446

Steel Sheet, Zinc-coated (Galvanized) by


the Hot-Dip Process, Structural (Physical)
Quality.

1.03 SYSTEM DESCRIPTION


A.

Lockers: Surface mounted, double tier lockers complete


with key cylinder locks.

1.04 MOCKUP
A.

Provide one full


selected color.

size

locker,

double

tier with

in

1.05 SUBMITTALS
A.

Submit shop drawings and product technical data.

B.

Include locker types, sizes, configurations, layout


of groups of lockers, accessories, and numbering plan.

C.

Submit manufacturer's installation instructions.

D.

Provide 2 color samples of each color scheduled for the


Engineer approval.

2. PART 2 - PRODUCTS
2.01 MATERIALS
A.

Sheet Steel: Conform to ASTM A 446; structural quality,


Grade as selected by manufacturer for the intended
application, galvanized, Mild, cold-rolled, levelled
steel; of the following minimum thicknesses:
-

Body and Shelf: 24 gage


Doors: 20 gage
10500-1
Metal Lockers

Door Inner Faces: 24 gage


Door Frames: 16 gage
Hinges: 14 gage
Base, Top and Trim: 22 gage

2.02 ACCESSORIES
A.

Provide
the
following
accessories for each locker:
-

manufacturer

standard

Coat hanger bar


Metal number plate.

2.03 FABRICATION
A.

Locker Units: Unless otherwise indicated, size shall be


300 mm wide x 450 mm deep x 750 mm high for each locker
unit

B.

Bodies: Formed and flanged


electrically spot welded.

C.

Door Frame: Formed channel shape,


flush, welded to body.

D.

Doors: Welded inner and outer faces; thickness as


appropriate for door leaf size; channel reinforced top
and bottom with intermediate stiffener ribs. Finish
edges smooth.

E.

Hinges: 3 for doors over 1050 mm high and 2 for doors


under 1050 mm high.
Weld securely to unit body and
rivet to unit door.

F.

Provide manufacturer standard key cylinder lock.

G.

Lockers shall have 450 mm high


steel bases
provided with 300mm width x 50mm thick hard wood clear
finish built-in
bench
on
metal
support frame
as
per
the approved
manufacturer standard product as shown
in Drawings.

H.

Finish edges smooth without burrs.

I.

Provide number plates.

with

stiffener
welded

ribs;

and ground

2.04 FINISHES
A.

Clean and degrease metal; prime and finish


coats of baked enamel.

with two

B.

Paint locker doors and bodies in colors indicated in


Interior Design Specifications. Locker door and body of
one color throughout.
10500-2
Metal Lockers

3. PART 3 - EXECUTION
3.01 PREPARATION
A.

Verify bases are properly sized and located.

3.02 INSTALLATION
A.

Install lockers secure, plumb, square,


Set on prepared base provided.

and in line.

B.

Anchor lockers with appropriate anchor devices to suit


materials encountered.

C.

Bolt adjoining locker units together to provide


rigid installation.

D.

Install end panels, filler panels, tops and bases to


completely close off openings.
END OF SECTION