Project name Reference Client name Revision Man Headquaters L8 -
Selection parameters of the indoor units can be found under the chapter Indoor unit details Selection parameters of the outdoor units can be found under the chapter Outdoor unit details Only the data published in the data book are correct. This program uses close approximations of these data.
1. Material List
Model RXYQ10T RXYQ12T FXMQ25P7 FXMQ32P7 FXMQ50P7 FXSQ40P FXSQ50P FXSQ63P FXSQ80P KHRQ22M20T KHRQ22M64T BRC1D52 Piping 1/4" Piping 3/8" Piping 1/2" Piping 5/8" Piping 3/4" Piping 1 1/8" Qty Description 1 Heat pump/Heating only VRV IV HP NCH 1 Heat pump/Heating only VRV IV HP NCH 1 VRV FXMQ - Concealed ceiling unit (large) 1 VRV FXMQ - Concealed ceiling unit (large) 1 VRV FXMQ - Concealed ceiling unit (large) 4 VRV FXSQ - Concealed ceiling mounted 2 VRV FXSQ - Concealed ceiling mounted 1 VRV FXSQ - Concealed ceiling mounted 1 VRV FXSQ - Concealed ceiling mounted 8 REFNET branch piping kit 2 REFNET branch piping kit 11 Remote controller 27.0m 27.0m 30.0m 53.0m 4.0m 33.0m
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
Page 1
PI-C 50Hz Power input in cooling at 50Hz PI-C 60Hz Power input in cooling at 60Hz PI-H 50Hz Power input in heating at 50Hz PI-H 60Hz Power input in heating at 60Hz
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
Page 2
Discharge temperature
Name Suct C IU-L8-02 IU-L8-01 IU-L8-03 IU-L8-04 IU-L8-06 IU-L8-05 IU-L8-08 IU-L8-11 IU-L8-07 IU-L8-09 IU-L8-10 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 Condition 1 Disch C 32.7 35.1 32.7 35.4 33.8 35.4 35.1 33.8 35.8 32.7 32.7 Airflow l/s 267 267 267 325 300 417 267 150 158 267 267 Suct C 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0 Condition 2 Disch C 33.3 36.1 33.3 36.5 34.5 36.4 36.1 34.5 36.8 33.3 33.3 Airflow l/s 267 267 267 325 300 417 267 150 158 267 267
Condition 1: The discharge temperature is calculated for an ambient temperature of -15.0C and a room temperature of 23.0C, as specified in the Preferences window. It also uses the maximum connection ratio of the installation and the corresponding fan speed of the indoor units. Condition 2: The discharge temperature is calculated using the design ambient temperature 0.0C, a room temperature of 22.0C and an operational connection ratio of maximum 130%. The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a thermal comfort level. The discharge temperature of condition 2 is lower than 35.0C. Reducing the connection ratio may compensate this and may raise the discharge temperature improving the thermal comfort level.
Name IU-L8-02 IU-L8-01 IU-L8-03 IU-L8-04 IU-L8-06 IU-L8-05 IU-L8-08 Sound dBA 29-37 29-37 29-37 30-37 35-39 32-38 29-37 220V 1ph 220V 1ph 220V 1ph 220V 1ph 220V 1ph 220V 1ph 220V 1ph PS MCA A 1.2 Factory Std 1.2 Factory Std 1.2 Factory Std 1.1 Factory Std 1.3 Factory Std 1.3 Factory Std 1.2 Factory Std Fuses WxHxD mm 700x300x700 700x300x700 700x300x700 1000x300x700 1000x300x700 1000x300x700 700x300x700 Wght kg 26 26 26 35 35 35 26 PI-C 50Hz kW 0.192 0.192 0.192 0.142 0.110 0.163 0.192 PI-C 60Hz kW 0.192 0.192 0.192 0.142 0.110 0.163 0.192 PI-H 50Hz kW 0.180 0.180 0.180 0.130 0.098 0.151 0.180 PI-H 60Hz kW 0.180 0.180 0.180 0.130 0.098 0.151 0.180
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
Page 3
MCA A
Fuses
Wght kg 23 23 26 26
0.6 Factory Std 0.6 Factory Std 1.2 Factory Std 1.2 Factory Std
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
Page 4
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
Page 5
Run Amps A
Sufficient distance should be respected between the modules according to the service & operation space rules as mentioned in the databook.
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
Page 6
4. Piping Diagrams
Pipes marked with * in the diagrams must be connected to the device with a reducing joint.
3/8"x7/8"
3.0m 4.0m 1/4"x1/2" 3/8"x5/8" KHRQ22M64T KHRQ22M20T IU-L8-02 FXSQ40P 1.0m 3/8"x5/8" 4.0m 1/4"x1/2" KHRQ22M20T IU-L8-01 FXSQ50P 2.0m 1/4"x1/2" IU-L8-03 FXSQ40P
2.0m 2.0m 3/8"x3/4" 3/8"x5/8" KHRQ22M64T KHRQ22M20T IU-L8-04 FXSQ63P 3.0m 3/8"x5/8" 2.0m 1/4"x1/2" KHRQ22M20T IU-L8-06 FXMQ50P7 5.0m 3/8"x5/8" IU-L8-05 FXSQ80P
2.0m 3/8"x3/4"
3.0m 3.0m 1/4"x1/2" 3/8"x5/8" KHRQ22M20T KHRQ22M20T IU-L8-08 FXSQ50P 3.0m 1/4"x1/2" IU-L8-11 FXMQ25P7
3.0m 3/8"x5/8"
KHRQ22M20T
3.0m 3/8"x5/8"
KHRQ22M20T
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
Page 7
5. Wiring Diagrams
P1P2 = Please select the cable type and size in accordance with the databook. F1F2 = Please select the cable type and size in accordance with the databook.
Q1,Q2
RXYQ10T
IU-L8-01 FXSQ50P
F1,F2
IU-L8-03 FXSQ40P
F1,F2
IU-L8-04 FXSQ63P
F1,F2
IU-L8-06 FXMQ50P7
F1,F2
IU-L8-05 FXSQ80P
F1,F2
IU-L8-08 FXSQ50P
F1,F2
IU-L8-11 FXMQ25P7
F1,F2
IU-L8-07 FXMQ32P7
F1,F2
IU-L8-09 FXSQ40P
F1,F2
IU-L8-10 FXSQ40P
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
Page 8
6. Device Options
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
Page 9