13/001

Moeller HPL0213-2001/2002

Contents

DM4 Soft Starters


Drives

DM4 Soft Starters

System selection

Page
11/010

System overview

13/002

Description
DM4 soft starters
DE4-KEY-2 LCD keypad

13/004
13/005

Engineering
Wiring examples

13/006

Selection data
DM4 soft starters
Assigned switching and protective elements

13/013
13/014

DM4 soft starters


DM4 basic units
DE4-KEY-2 LCD keypad
Documentation

13/018
13/019
13/019

Technical data
DM4 Soft Starters

13/020

Dimensions

13/028

13/002

Moeller HPL0213-2001/2002

System Overview

N
RU

IF
SH
ST
O

PR

DM4 Soft Starters

Moeller HPL0213-2001/2002

13/003

System Overview

DM4 soft starters


Motor rating from
7.5 to 500 kW for in-line
connection (upstream of load, standard)
11 to 900 kW for in-delta
connection ( 3 circuit)
10 predefined standard applications allow
DOL operation, and parameter set selection via rotary switches
Integrator time adjustable from 1 to 255 s
Energy-saving function optimizes efficiency coefficient and power factor
Adjustable current limitation prevents
high starting currents
Actuator operation for 3-phase resistive
and inductive loads from 16 to 900 A
(400 V)
Selection data a Page 13/013
Ordering information a Page 13/018

Accessories
3

DE4-KEY-2 LCD keypad


Pluggable to DM4 soft starters, with
8 function keys and plain text display,
language selectable (German/English)

DM4 Soft Starters

Basic units

Ordering information a Page 13/019

Communication cards
DE4-COM-2X
serial RS485/RS232 interface

DE4-NET-K
Suconet K interface
DE4-NET-DP
PROFIBUS-DP interface
DE4-NET-S
INTERBUS interface
Ordering information a Page 16/009

Super fast semiconductor fuses


Fuses for protecting semiconductors,
either for direct installation in DM4 soft
starters or for external mounting

Selection data a Page 13/014


Ordering information a Page 16/011

Fuse base
For external mounting of super fast semiconductor fuses
Ordering information a Page 16/011

13/004

Moeller HPL0213-2001/2002

DM4 Soft Starters

Description
DM4 Soft Starters

DM4 soft starters/three-phase regulators: Product Features

Typical fields of application as soft starter

The units of the DM4 series round off the top end of Moellers soft starter program.
With a rating range starting at 7.5 kW, the DM4 soft starters are suitable for
demanding automation tasks. The key features of the DM4 range are:
Current limitation
High overload withstand capability
Large rating range up to 500 kW
(or 900 kW in in-delta connection)
Predefined parameter sets for standard applications
selectable
All parameters also individually adjustable
Keypad with plain text display (optional)
Programmable relay and analog outputs
Networkable
Voltage regulator function (generalized phase control) can be implemented for
each software changeover

Pump drives:
The soft start prevents sudden pressure surges. The mechanical load on the plant
drops and the lifespan of the plant components is increased.
Fan drives and compressors:
The soft start prevents belt slippage, and therefore premature wear. This in turn
lowers operating costs and increases plant life.
Conveyors:
Instead of starting with a jolt, the conveyor starts up gently and the transported
items do not fall over. The mechanical stress on the conveyor is reduced and its
lifespan therefore increased.
Circular saws, bandsaws:
Due to the current limitation at start-up, current peaks are avoided. This results
in energy savings and reduced electricity bills and peak load tariffs.
Agitators, mixers: as above.
Mills, breakers: as above.

Operation as 3-phase soft starter


The units of the DM4 series are soft starters for standard
three-phase asynchronous motors.
The connection type determines the rating range:
In in-line connection (upstream of load, standard):
7.5 kW to 500 kW at 400 V
In in-delta connection: 11 kW to 900 kW at 400 V,
each phase of the soft starter being connected in series with the individual motor
windings (6 lines required, motor in delta circuit only).
The DM4 soft starters are factory preset for the most common applications. For various standard applications, parameter sets can be selected via an application selector switch, thereby removing the need for manually configuring the device and the
associated risk of errors.
The preset, application-specific parameter sets can also be selected via an optional
keypad with plain text display.
All parameters can be displayed, edited and matched to specific applications with
the keypad.
The keypad is also required for reprogramming the soft starters digital and analog
inputs and outputs.
Interface modules can be used as an alternative to the keypad.
The soft starters can be interfaced with a PLC via Suconet K, PROFIBUS-DP or
INTERBUS. For defining parameters, via a PLC, the same functions are available as
with the LCD keypad. The same software modules can be used for PLCs and frequency inverters.

Moeller HPL0213-2001/2002

13/005

Description
DM4 Soft Starters, DE4-KEY-2 Keypad
Operation as three-phase regulator

DM4 Soft Starters

The DM4 units can be changed over by software to three-phase regulator operation.
The rating range is 16 A to 900 A at 400 V (standard connection only, in-delta connection not possible).
They can be operated both in pure regulator mode or with a closed-loop control circuit.
The units each have two analog inputs for setpoint/actual values and an additional
built-in current feedback loop.
For setting the parameters for actuator operation, a keypad or the serial interface
with PC software is required.
Typical fields of application as three-phase regulator
Heater loads:
Continuous temperature regulation reduces the thermal and mechanical load on
the heating elements and therefore increases their lifespan.
Lighting control:
Gentle lighting up of lamps reduce cold-state current consumption. By using the
optimum operating point of the lights, energy consumption is lowered without
reducing light output, and the lifespan is increased.
This results in lower electricity bills and peak load tariffs.
Ozone generators:
Regulation of high-voltage transformers.
Documentation
Delivery of each device with complete documentation in PDF format on CD is in
preparation. Printed versions are available on request.
Documentation for DM4-340 soft starters a Page 13/019
Documentation for DE4-KEY-2 keypads a Page 13/019
DE4-KEY-2 keypad
The DM4 soft starters are factory preset for the most common applications. For various standard applications, parameter sets can be selected via an application selector switch.
These parameter sets can also be selected with the DE4-KEY-2 keypad. With the
keypad, all parameters can be viewed, edited and adapted for specific applications.
In addition, the drive can be controlled using the keypad.
The DE4-KEY-2 keypad has a two-line plain text display. Menus guide the user
through the parameterization. The display language can be changed (German/
English). During operation, the current motor current is displayed.
Various status symbols conveniently indicate operating states. In the Stop state, a
clear red LED on the Stop key is lit.
To connect the keypad, it is simply plugged into the soft starter. It can be connected
and disconnected during operation.
The keypads intergral memory saves the entered parameter set and retains it even
when the power is disconnected. Where several frequency inverters are used, the
parameter set can therefore be copied from one frequency inverter to another.

13/006

Moeller HPL0213-2001/2002

Engineering
Wiring Examples
Immediate disable without ramp function
Operation

DM4 Soft Starters

For this function, the circuit shown must be


added to all of the following circuit options.
The parameter settings required for input E2 are described in the manual.

EMERGENCY STOP

S1

S1:
S2:
G1:

K1

S2

Off
On
Enable (E2 = 1 a enabled)

K1

K1

G1

E2
39

Integration of the Z-relay

Z1
S1

S2

K2

Wiring

Z1

Z1

K1

K1

S3

K1

S4

L1
L2
L3
N
PE

S3

K2

S4

K2

K2

G1

Z1

E1
39

K2

K1

K2

K2

Q1
G1 RUN

13

I> I> I>

14

K1M

G1

E1
39

K1M

Z1

d
F2

The motor-protective relays signal contacts are incorporated in the On/Off circuit. Under fault conditions, the soft starter is inhibited without delay and the
motor spins down. The K1M mains contactor drops out as soon as the Run
relay drops out.
The motor-protective relays signal contacts are incorporated in the soft start/
stop circuit. Under fault conditions, the soft starter ramps down. The soft
starter is de-energized, but the mains contactor remains on.
To switch the mains contactor off as well, a second contact of the motor-protective relay must be incorporated in the branch of the K1M mains contactor
in addition to variant 2. After completion of the soft stop, the Run relay drops
out, thereby cancelling the holding circuit of the K1M.
Soft stop
Soft start

b
c

G1

M
3

T1, T2: thermistor

+
6T3

Off
On
Enable (E2 = 1 a enabled)

2T1
4T2

S1:
S2:
G1:

1L1
2L2
3L3

EMERGENCY STOP

T1

T2

Moeller HPL0213-2001/2002

13/007

Engineering
Wiring Examples
Soft starter with mains contactor (K1M)
Operation

K1
S3
S1

S2

a:

See Operation

13

S4

K1

Off
On
Soft stop
Soft start
Enable
Soft stop
Soft start

K2

K2

K1

G1 RUN

14

K1

K1

E2

G1

K2

39

E1

G1

K1M

39

Wiring

L1
L2
L3
N
PE

Q2

Q1
I > I > I>

K1M

I > I > I>

F1
a

G1

14

23

24

33

K4

34

43

Analog Out 2

13

K3

Analog Out 1

T2

K2;TOR

62

63

I mot
M
3~

M1

0 V Analog

- Thermistor

T1

6T3

4T2

2T1

PE

+ Thermistor

K1;RUN

REF 1: 010 V

+12

REF 2: 420 mA

39

+12 V DC

E2

0 V Analog

E1

Enable

0 V (E1;E2)

Start/Stop

5L3

3L2

1L1

F2

DM4 Soft Starters


Drives

EMERGENCY STOP
S1:
S2:
S3:
S4:
a:
b:

13/008

Moeller HPL0213-2001/2002

Engineering
Wiring Examples
Soft starter without separate mains contactor (K1M)
Operation
EMERGENCY STOP

DM4 Soft Starters

K1
S2

S1

S1:
S2:
a:
b:

Soft stop
Soft start
Enable
Soft stop
Soft start

a:

See Operation

K1

E2

K1

G1

E1

G1

39

39

Wiring

L1
L2
L3
N
PE

Q2

Q1
I> I> I>

I> I> I>

F1
a

G1

14

23

24

33

K4

34

43

Analog Out 2

13

K3

Analog Out 1

T2

K2;TOR

62

63

I mot
M
3~

M1

0 V Analog

- Thermistor

T1

6T3

4T2

2T1

PE

+ Thermistor

K1;RUN

REF 1: 010 V

+12

REF 2: 420 mA

39

+12 V DC

E2

0 V Analog

E1

Enable

0 V (E1;E2)

Start/Stop

5L3

3L2

1L1

F2

Moeller HPL0213-2001/2002

13/009

Engineering
Wiring Examples
Soft starter with bypass and mains contactor (K1M)
Operation

K1
S3

S1

S2

K1

K2M

K1

S4

K2

K2

K1 G1 RUN

13
14

Off
On
Soft stop
Soft start
Enable
Soft stop
Soft start

a:

See Operation

23

G1 TOR

24

K1

E2

G1

E2

G1

K2

39

K1M

39

K2M

Wiring

L1
L2
L3
N
PE

Q1

Q2
I> I> I>

I> I>I>

K1M
F1
a

13

23

14

24

K3

33

34

K4

43

Analog Out 2

T2

K2;TOR

62

63

I mot

M1

M
3~

PE

Analog Out 1

- Thermistor

T1

K1;RUN

0 V Analog

+ Thermistor
6T3

2T1

4T2

G1

REF 1: 010 V

+12

REF 2: 420 mA

39

+12 V DC

E2

0 V Analog

E1

Enable

~
K2M

0 V (E1;E2)

Start/Stop

5L3

3L2

1L1

F2

DM4 Soft Starters


Drives

EMERGENCY STOP
S1:
S2:
S3:
S4:
a:
b:

13/010

Moeller HPL0213-2001/2002

Engineering
Wiring Examples
Soft starter with mains contactor (K1M),
in-delta connection
Operation
EMERGENCY STOP

DM4 Soft Starters

K1
S3
S1

S2

Off
On
Soft stop
Soft start
Enable
Soft stop
Soft start

a:

See Operation

13

S4

K1

S1:
S2:
S3:
S4:
a:
b:

K2

K2

K1

G1 RUN

14

K1

K1

E2

G1

K2

39

E1

G1

K1M

39

Wiring

L1
L2
L3
N
PE

Q2

Q1
I> I> I>

I> I> I>

K1M
F1
a

U2

13

23

14

24

K3

33

K4

34

43

Analog Out 2

T2

K2;TOR

PE

Analog Out 1

- Thermistor

T1

K1;RUN

0 V Analog

+ Thermistor
6T3
U1

4T2
V2

M
3~
W2

M1

V1

W1

2T1

G1

REF 1: 010 V

+12

REF 2: 420 mA

39

+12 V DC

E2

0 V Analog

E1

Enable

0 V (E1;E2)

Start/Stop

5L3

3L2

1L1

F2

62

63

I mot

13/011

Moeller HPL0213-2001/2002

Engineering
Wiring Examples
Soft starter with reversing circuit
Operation

DM4 Soft Starters


Drives

K1

K1

K1
S1

K2M

K1M
S4

S1
K4

S2

K1

K1

K2

K2

K3

K4

K1M

K3

K2M

S5

K5

G1 RUN

K5

13
14

E2

K1

G1

E1

K2

39

K1M

K3

K2M

K5

G1

39

K4

EMERGENCY
S1:
S2:
S4:
S5:

Off
On
Soft stop
Soft start

a:
b:
c:
d:

Enable
Soft stop
Soft start
Forward
Reverse

Wiring

L1
L2
L3
N
PE
Q1

Q2
I> I> I>

K1M

F1
a:

K3

K4

13

14

23

24

33

34

43

I mot
M1

M
3~

REF 1: 010 V

PE

REF 2: 420 mA

Analog Out 2

T2

K2;TOR

Analog Out 1

Thermistor

T1

+12

0 V Analog

+ Thermistor
6T3

4T2

K1;RUN

39

+12 V DC

E2

0 V Analog

G1

E1
Enable

0 V (E1;E2)

Start/Stop

5L3

3L2

1L1

F2

2T1

K2M

I> I> I>

62

63

See Operation

13/012

DM4 Soft Starters

Notes

Moeller HPL0213-2001/2002

Moeller HPL0213-2001/2002

13/013

Selection Data
DM4 Soft Starters

Power section
Mains supply voltage UL (45 65 Hz 0 %)
Control voltage
Rated operational current Ie
Recommended motor rating
In-line connection
(upstream of load, standard)
In-delta connection
(in series with each motor winding)
Internal bypass relay
Standards
Degree of protection
Fields of application
1-phase loads
(heaters, lamps, electroplating)
3-phase loads
(heaters, lamps, electroplating)
3-phase motors
Functions
Fast switching (semiconductor contactor)
Soft start function
Reversing contactor function
Suppression of
closing transients
Current limitation
Overload monitoring
Underload monitoring
Analog inputs
Analog outputs
Programmable digital inputs
Programmable relay outputs
Thermistor input
Fault memory
Pre-programmed parameter sets
Suppression of DC components
for motors
Potential isolation between power and
control sections
Interfaces (optional)
Notes

230 V 15 % to 460 V +15 %


24 V to 230 V AC/DC
16 900 A
7.5 kW 500 kW (400 V)
11 kW 900 kW (400 V)

IEC/EN 60 947-4-2
IP20
Soft starting of three-phase asynchronous motors

K
K
(minimum ramp time 1s)
K
External solution required
K
K
K
K
1 x 0 10 V DC; 1 x 4 20 mA
2 x 0 10 V DC, 10 mA
2
4 make contacts, 3 of which floating
K
5 faults
10 different standard applications:
various fans, pumps and compressors
K
K
In preparation
K Standard fittings

DM4 Soft Starters

DM4...

DM4 Soft Starters

P
kW

Motor
rating at
400 V

I
A

Device

Ie
A

Motor

Notes

DM4-340-400K
DM4-340-500K

DM4-340-90K
DM4-340-132K
DM4-340-160K
DM4-340-200K
DM4-340-250K
DM4-340-315K

DM4-340-45K
DM4-340-55K
DM4-340-75K

DM4-340-30K

In-delta connection
(in series with each motor winding)
DM4-340-7K5
DM4-340-11K
DM4-340-15K
DM4-340-22K

11
15
22
30
37
45
55
75
90
110
132
160
200
250
315
400
500
560
750
900

16
23
30
44
44
59
59
85
105
146
146
174
242
300
370
500
600
600
750
900

21.7
29.3
41
55
68
81
99
134
161
196
231
279
349
437
544
683
860
960
1280
1540

21.7
29.3
41
55
68
81
99
134
161
196
231
279
349
437
544
683
860
960
1280
1540

16
23
30
44
59
72
85
105
146
174
202
242
300
370
500
600
750
900

I
A

Cable3)

Rated operational current2)

Soft starter for three-phase mains connection, short starting time,


tripping class 10 (15 s, 3.5 x Ie)
In-line connection
(upstream of load, standard)
DM4-340-7K5
7.5
16
15.2
DM4-340-11K
11
23
21.7
DM4-340-15K
15
30
29.3
DM4-340-22K
22
44
41
DM4-340-30K
30
59
55
DM4-340-37K
37
72
68
DM4-340-45K
45
85
81
DM4-340-55K
55
105
99
DM4-340-75K
75
146
134
DM4-340-90K
90
174
161
DM4-340-110K
110
202
196
DM4-340-132K
132
242
231
DM4-340-160K
160
300
279
DM4-340-200K
200
370
349
DM4-340-250K
250
500
437
DM4-340-315K
315
600
544
DM4-340-400K
400
750
683
DM4-340-500K
500
900
860

Type 1)

Selection Data
Assigned Switching and Protective Elements

13/014

DIL0AM
DIL1M
DIL2M
DIL2AM
DIL3M80
DIL3AM85
DIL4M115
DIL4AM145
DILM185
DILM225
DILM250
DILM300
DILM400
DILM500
DILM580
DILM750

DIL0M
DIL0AM
DIL1M
DIL2M
DIL2AM
DIL3M80
DIL3AM85
DIL4M115
DIL4AM145
DILM185
DILM225
DILM250
DILM300
DILM400
DILM500
DILM580
DILM750

Mains
contactor
(optional)4)

Z00-16 + EZ007)
Z00-24 + EZ007)
Z00-40 + EZ17)
Z00-57 + EZ17)
Z00-57 + EZ17)
Z00-63 + EZ17)
Z00-63 + EZ17)
Z5-100/KK47)
Z5-125/KK47)
Z5-150/KK47)
Z5-150/KK47)
Z5-150/FF67)
ZW7-2907)
ZW7-4007)
ZW7-4007)
ZW7-5407)
ZW7-6307)
ZW7-6307)
ZWA-8207)

Z00-16
Z00-24
Z1-40
Z1-57
Z1-63
Z5-100/SK3
Z5-100/SK3
Z5-125/SK4
Z5-150/SK4
Z5-220/FF6
Z5-220/FF6
ZW7-290
ZW7-400
ZW7-400
ZW7-540
ZW7-630
ZWA-820

Motor protective
relay5)

other switch operations, effective current value changes, so that a


higher-rated unit may be required. The switching and protective
elements listed are each dimensioned for the following switching
cycle (no bypass with all switching operations):
Units DM4-340-7K5 to DM4-340-90K, ten switch operations per hour, uninterrupted duty
Units DM4-340-110K and DM4-340-132K, ten switch operations per hour
with at least three minutes current-free interval before the next start
Units from DM4-340-160K, three switch operations per hour with at least
eight minutes current-free interval before the next start.
With other switch operations or when using a bypass, the effective rating
and therefore the required unit changes.
The rated operational current (unit) must always be higher than the motor current (in-line operation) or motor current/ 3 (in-delta operation) indicated on
the motors nameplate.

1) With

PKM0-25 (+ CL-PKZ0)
PKZ2 + M-32-PKZ2 (+ CL-PKZ2)
NZM7-63N-OBI
NZM7-63N-OBI
NZM7-80N-OBI
NZM7-100N-OBI
NZM7-125N-OBI
NZM7-160N-OBI
NZM7-200N-OBI
NZM7-200N-OBI
NZM10-400S/ZMM4006)
NZM10-400S/ZMM4006)
NZM10-400S/ZMM4006)
NZM10-630S/ZMM-6306)
NZM10-630S/ZMM-6306)
NZM14-800S
NZM14-1000S + R-NZM14
NZM14-1250S + R-NZM14
NZM14-1600H + R-NZM14
IZM32-2000 + M(200-240VAC)-IZM

PKM0-16 (+ CL-PKZ0)
PKM0-25 (+ CL-PKZ0)
PKZ2 + M-32-PKZ2 (+ CL-PKZ2)
NZM7-63N-OBI
NZM7-63N-OBI
NZM7-80N-OBI
NZM7-100N-OBI
NZM7-125N-OBI
NZM7-160N-OBI
NZM7-200N-OBI
NZM7-200N-OBI
NZM10-400S/ZMM4006)
NZM10-400S/ZMM4006)
NZM10-400S/ZMM4006)
NZM10-630S/ZMM-6306)
NZM10-630S/ZMM-6306)
NZM14-800S
NZM14-1000S + R-NZM14

Line protection

Soft starter function

Moeller HPL0211-2001/2002

S00UF1/80/40A/660V
S00UF1/80/80A/660V
S00UF1/80/80A/660V
S00UF1/80/125A/660V
S00UF1/80/125A/660V
S00UF1/80/125A/660V
S00UF1/80/125A/660V
S00UF1/80/200A/660V
20.610.32-350
20.610.32-350
20.610.32-350
20.610.32-450
20.610.32-500
20.610.32-500
20.610.32-630
20.630.32-900
20.630.32-900
20.630.32-900
20.630.32-1250
20.630.32-1250

S00UF1/80/40A/660V
S00UF1/80/80A/660V
S00UF1/80/80A/660V
S00UF1/80/125A/660V
S00UF1/80/125A/660V
S00UF1/80/200A/660V
S00UF1/80/200A/660V
20.610.32-350
20.610.32-350
20.610.32-450
20.610.32-450
20.610.32-500
20.610.32-500
20.610.32-630
20.630.32-900
20.630.32-900
20.630.32-1250
20.630.32-1250

Semiconductor fuse (optional, required


fuse for type 2 coordination)

Rated operational current related to the specified load cycle.


Specifies the current for which the incomer must be dimensioned for the stated
operation and motor current. For higher motor currents and other switching
operations (operating frequency, overcurrent, overcurrent time, DF), the current
value will change and must be adjusted accordingly.
4) If the control ensures that, in the event of an EMERGENCY STOP, the regulator
is disabled before the mains contactor is switched off, the contactor specified in
column Bypass contactor can also be used as a mains contactor.
5) If the soft starter is to be continuously on, it can take on the function
of the motor protective relay.
For in-delta connection, set the motor protective relay to the value motor
current/ 3 .
6) Set ZMM trip block to t =  (OBI)
r
7) For in-delta connection, connect the motor-protective relay in series with the
motor winding (set value is motor current/ 3 ).
3)

2)

DIL00M
DIL0M
DIL0M
DIL1M
DIL1M
DIL2M
DIL2M
DIL2M
DIL4M115
DIL4M115
DIL4M115
DILM185
DILM225
DILM250
DILM400
DILM500
DILM580
DILM580
DILM750
NZM14-1000 + R-NZM14

DIL00M
DIL0M
DIL0M
DIL1M
DIL2M
DIL2M
DIL2M
DIL3M80
DIL4M115
DILM185
DILM185
DILM225
DILM250
DILM300
DILM400
DILM500
DILM650
NZM14-1000 + R-NZM14

Bypass contactor (optional)

Selection Data
Assigned Switching and Protective Elements

Moeller HPL0211-2001/2002

13/015

DM4 Soft Starters

DM4 Soft Starters

P
kW

Motor
rating at
400 V

I
A

Device

Ie
A

Motor

Notes

DM4-340-110K
DM4-340-160K
DM4-340-200K
DM4-340-250K
DM4-340-315K
DM4-340-400K
DM4-340-500K

DM4-340-37K
DM4-340-45K
DM4-340-55K
DM4-340-75K
DM4-340-90K

In-delta connection
(in series with each motor winding)
DM4-340-7K5
DM4-340-15K
DM4-340-22K
DM4-340-30K

11
15
22
30
37
45
55
75
90
110
132
160
200
250
315
400
500
560

13
22
30
44
44
55
72
85
105
140
140
170
240
280
350
450
550
700

21.7
29.3
41
55
68
81
99
134
161
196
231
279
349
437
544
683
860
960

31
41
58
78
96
114
140
189
227
276
326
393
492
616
767
963
1213
1354

21
31
41
58
78
96
114
140
189
227
276
326
393
492
616
767
963

I
A

Cable3)

Rated operational current2)

Soft starters for three-phase mains connection, long startup time,


tripping class 20 (40 s, 3.5 x Ie)
In-line connection
(upstream of load, standard)
DM4-340-11K
7.5
16
15.2
DM4-340-15K
11
22
21.7
DM4-340-22K
15
30
29.3
DM4-340-30K
22
44
41
DM4-340-37K
30
55
55
DM4-340-45K
37
72
68
DM4-340-55K
45
85
81
DM4-340-75K
55
105
99
DM4-340-90K
75
140
134
DM4-340-110K
90
170
161
DM4-340-132K
110
200
196
DM4-340-160K
132
240
231
DM4-340-200K
160
280
279
DM4-340-250K
200
350
349
DM4-340-315K
250
450
437
DM4-340-400K
315
550
544
DM4-340-500K
400
700
683

Type 1)

Selection Data
Assigned Switching and Protective Elements

13/016

DIL0AM
DIL1M
DIL2M
DIL2AM
DIL3M80
DIL4M115
DIL4M115
DILM185
DILM225
DILM250
DILM300
DILM400
DILM500
DILM580
DILM750
DILM750

DIL0M
DIL0AM
DIL1M
DIL2M
DIL2AM
DIL3M80
DIL4M115
DIL4M115
DILM185
DILM225
DILM250
DILM300
DILM400
DILM500
DILM580
DILM750

Mains
contactor
(optional) 4)

ZEV + ZEV-XSW-25 7)
ZEV + ZEV-XSW-25 7)
ZEV + ZEV-XSW-65 7)
ZEV + ZEV-XSW-65 7)
ZEV + ZEV-XSW-65 7)
ZEV + ZEV-XSW-65 7)
ZEV + ZEV-XSW-145 7)
ZEV + ZEV-XSW-145 7)
ZEV + ZEV-XSW-145 7)
ZEV + ZEV-XSW-145 7)
ZEV + ZEV-XSW-145 7)
ZEV + ZEV-XSW-820 7)
ZEV + ZEV-XSW-820 7)
ZEV + ZEV-XSW-820 7)
ZEV + ZEV-XSW-820 7)
ZEV + ZEV-XSW-820 7)
ZEV + ZEV-XSW-820 7)
ZEV + ZEV-XSW-820 7)

ZEV + ZEV-XSW-25
ZEV + ZEV-XSW-25
ZEV + ZEV-XSW-65
ZEV + ZEV-XSW-65
ZEV + ZEV-XSW-65
ZEV + ZEV-XSW-145
ZEV + ZEV-XSW-145
ZEV + ZEV-XSW-145
ZEV + ZEV-XSW-145
ZEV + ZEV-XSW-820
ZEV + ZEV-XSW-820
ZEV + ZEV-XSW-820
ZEV + ZEV-XSW-820
ZEV + ZEV-XSW-820
ZEV + ZEV-XSW-820
ZEV + ZEV-XSW-820
ZEV + ZEV-XSW-820

5)

Motor protective relay

different operating cycles, the r.m.s. value changes, so that a


higher-rated device may be necessary. The switching and protective
elements listed are each dimensioned for the following operating
cycle (no bypass for all operating cycles):
Devices DM4-340-7K5 to DM4-340-90K, ten operations per hour, uninterrupted duty
Units DM4-340-110K and DM4-340-132K, ten switch operations per hour
with at least three minutes current-free interval before the next start
Devices from DM4-340-160K, three operations per hour with at least eight
minutes zero-current pause before the next start.
For other operating cycles or on use of a bypass, the useable power and
therefore the required device changes.
The rated operational current (device) must be greater in each case than the
motor current (in-line operation) or motor current/ 3 (in-delta operation)
indicated on the motors ratings plate.

1) At

PKZ2 + M-32-PKZ2 (+ CL-PKZ2)


NZM7-63N-OBI
NZM7-63N-OBI
NZM7-80N-OBI
NZM7-100N-OBI
NZM7-160N-OBI
NZM7-160N-OBI
NZM7-200N-OBI
NZM7-250N-OBI
NZM10-400S/ZMM-4006)
NZM10-400S/ZMM-4006)
NZM10-400S/ZMM-4006)
NZM10-630S/ZMM-6306)
NZM10-630S/ZMM-6306)
NZM14-800S
NZM14-1000S + R-NZM14
NZM14-1250S + R-NZM14
NZM14-1600S + R-NZM14

PKM0-25 (+ CL-PKZ0)
PKZ2 + M-32-PKZ2 (+ CL-PKZ )
NZM7-63N-OBI
NZM7-63N-OBI
NZM7-80N-OBI
NZM7-100N-OBI
NZM7-160N-OBI
NZM7-160N-OBI
NZM7-200N-OBI
NZM7-250N-OBI
NZM10-400S/ZMM-4006)
NZM10-400S/ZMM-4006)
NZM10-400S/ZMM-4006)
NZM10-630S/ZMM-6306)
NZM10-630S/ZMM-6306)
NZM14-800S
NZM14-1000S + R-NZM14

Cable protection

Soft starter function

Moeller HPL0211-2001/2002

S00UF1/80/40A/660V
S00UF1/80/80A/660V
S00UF1/80/125A/660V
S00UF1/80/125A/660V
S00UF1/80/125A/660V
S00UF1/80/200A/660V
S00UF1/80/200A/660V
20.610.32-350
20.610.32-350
20.610.32-450
20.610.32-450
20.610.32-450
20.610.32-500
20.610.32-630
20.630.32-900
20.630.32-900
20.630.32-1250
20.630.32-1250

S00UF1/80/80A/660V
S00UF1/80/80A/660V
S00UF1/80/125A/660V
S00UF1/80/125A/660V
S00UF1/80/200A/660V
S00UF1/80/200A/660V
20.610.32-350
20.610.32-350
20.610.32-450
20.610.32-450
20.610.32-500
20.610.32-500
20.610.32-630
20.630.32-900
20.630.32-900
20.630.32-1250
20.630.32-1250

Semiconductor fuse (optional, required


fuse for type 2 coordination)

Rated operational current related to the specified load cycle.


Specifies the current for which the incomer must be dimensioned for the stated
operation and motor current. For higher motor currents and other switching
operations (operating frequency, overcurrent, overcurrent time, DF), the current
value will change and must be adjusted accordingly.
4) If the control ensures that, in the event of an EMERGENCY STOP, the regulator
is disabled before the mains contactor is switched off, the contactor specified in
column Bypass contactor can also be used as a mains contactor.
5) If the soft starter is to be continuously on, it can take on the function
of the motor protective relay.
For in-delta connection, set the motor protective relay to the value motor
current/ 3 .
6) Set ZMM trip block to t =  (OBI)
r
7) For in-delta connection, connect the motor-protective relay in series with the
motor winding (set value is motor current/ 3 ).
3)

2)

DIL0M
DIL0M
DIL1M
DIL2M
DIL2M
DIL2M
DIL3M80
DIL4M115
DILM185
DILM185
DILM225
DILM250
DILM300
DILM400
DILM500
DILM650
NZM14-1000 + R-NZM14
NZM14-1000 + R-NZM14

DIL00M
DIL0M
DIL0M
DIL1M
DIL2M
DIL2M
DIL2M
DIL3M80
DIL4M115
DILM185
DILM185
DILM225
DILM250
DILM300
DILM400
DILM500
DILM650

Bypass contactor (optional)

Selection Data
Assigned Switching and Protective Elements

Moeller HPL0211-2001/2002

13/017

DM4 Soft Starters

13/018

Moeller HPL0213-2001/2002

DM4 Soft Starters

DM4 Soft Starters


DM4 Basic Units

Supply voltage

Rated operational current

Rated output
for
3h motors at
400 V

UL
V

Ie
A

P
kW

190 520 V AC g 0 %

16

7.5

23

11

30

15

44

22

59

30

72

37

85

45

105

55

146

75

174

90

202

110

242

132

300

160

370

200

500

250

600

315

750

400

900

500

Type
Article no.

Price
See Price List

Std.
pack

Soft starters up to 37/55 kW 1)


at 400 V
DM4-340-7K5
207897
DM4-340-11K
207898
DM4-340-15K
207899
DM4-340-22K
207900
DM4-340-30K
207901
DM4-340-37K
207902

1 off

DM4-340-45K
207903
DM4-340-55K
207904
DM4-340-75K
207905

1 off

DM4-340-90K
207906
DM4-340-110K
207907
DM4-340-132K
207908
DM4-340-160K
207909
DM4-340-200K
207910

1 off

DM4-340-250K
207911
DM4-340-315K
207912
DM4-340-400K
207913
DM4-340-500K
207914

1 off

Soft starters up to 75/132 kW 1)


at 400 V
190 520 V AC g 0 %

Soft starters up to 200/315 kW 1)


at 400 V
190 520 V AC g 0 %

Soft starters up to 500/900 kW 1)


at 400 V
190 520 V AC g 0 %

Notes

1)

Ratings apply to in-line/in-delta connection.

13/019

Moeller HPL0213-2001/2002

DM4 Soft Starters


DE4-KEY-2 LCD Keypad, Documentation
Price
See Price List

Std.

Keypad
Allows all soft starter parameters to be adapted for any
application. The drive can also be controlled via the keypad.
Connection to soft starter by simply mounting/removing keypad,
also during operation
With retentive memory for parameters.
In series operation, parameter sets can be transmitted
from one soft starter to the other.
Two-line plain text display
Status symbols for indication of operating status

DE4-KEY-2
211291

Type
Article no.

1 off

Price
See Price List

Std.

Documentation
Delivery of each device with complete documentation in PDF format
on CD is in preparation. Printed versions are available on request.
DM4-340 Soft Starter, Hardware and Engineering

German
English

Soft Starter Configuration, Engineering

German
English

DE4-KEY-2 Keypad, Hardware and Engineering

German
English
Italian
Spanish

AWB8250-1341D
214791
AWB8250-1341GB
214792
AWB8250-1346D
214793
AWB8250-1346GB
214794
AWB8240-1344D
214795
AWB8240-1344GB
214796
AWB8240-1344I
223197
AWB8240-1344E
223198

1 off

DM4 Soft Starters

Type
Article no.

DM4 Soft Starters

Type 2 coordination, in addition

Short-circuit strength
Type 1 coordination

AC-53b (with bypass)

Pollution degree
Power dissipation at
rated operational current Ie
Dimensions (W x H x D)
Weight
Main conducting paths
Rated operational voltage Ue
Rated insulation voltage Ui
Mains frequency
Control section power supply
Rated operational current Ie
AC-53
Assigned motor rating
(standard connection)
230 V
400 V
460 V
Phase current
(in-delta connection)
Assigned rating
(in-delta connection)
230 V
400 V
460 V
Overload cycle to
IEC/EN 60 947-4-2
AC-53a (without bypass)

General
Standards
Climatic proofing
Ambient temperature, min./max.
Storage temperature, min./max.
Altitude
Mounting position
Degree of protection
Protection against accidental contact

Technical Data

13/020

23 A : AC-53a :
335 : 9910
23 A : AC-53b :
335 : 120

4
7.5
10
27

7.5
11
20

16 A : AC-53a :
335 : 9910
16 A : AC-53b :
335 : 120

kW
kW
HP
A

kW
kW
HP

S00UF1/80/40A/660V

PKZM0-16

11
15
25

16

S00UF1/80/80A/660V

PKZM0-25

5.5
11
15
39

23

S00UF1/80/80A/660V

PKZ2/ZM-32

30 A : AC-53a :
335 : 9910
30 A : AC-53b :
335 : 120

15
22
30

7.5
15
20
51

30

230 460
460
50/60
110/230

S00UF1/80/125A/660V

NZM7-63N

44 A : AC-53a :
335 : 9910
44 A : AC-53b :
335 : 120

22
37
50

11
22
30
76

44

230 460
460
50/60
110/230

S00UF1/80/125A/660V

NZM7-63N

59 A : AC-53a :
335 : 9910
59 A : AC-53b :
335 : 120

30
55
75

15
30
40
102

59

230 460
460
50/60
110/230

S00UF1/80/200A/660V

NZM7-80N

72 A : AC-53a :
335 : 9910
72 A : AC-53b :
335 : 120

37
55
100

18.5
37
50
124

72

230 460
460
50/60
110/230

222 x 290 x 195


6.7

S00UF1/80/200A/660V

NZM7-100N

85 A : AC-53a :
335 : 9910
85 A : AC-53b :
335 : 120

45
75
100

22
45
60
147

85

230 460
460
50/60
110/230

222 x 420 x 195


15

20.610.32-350

NZM7-100N

105 A : AC-53a :
335 : 9910
105 A : AC-53b :
335 : 120

55
90
150

30
55
75
181

105

230 460
460
50/60
110/230

222 x 420 x 195


15

2
276

230 460
460
50/60
110/230

222 x 290 x 195


6.7

2
227

230 460
460
50/60
110/230

222 x 290x 195


6.7

2
190

V AC
V AC
Hz
V AC

222 x 290x 195


6.7

2
120

222 x 290x 195


6.7

2
91

222 x 290x 195


6.7

DM4-340-55K

mm
kg

DM4-340-45K

2
152

DM4-340-37K

2
63

DM4-340-30K

2
50

DM4-340-22K

DM4-340-15K

25 to +55 C

IEC/EN 60 947-4-2

DM4-340-90K

20.610.32-350

NZM7-160N

146 A : AC-53a :
335 : 9910
146 A : AC-53b :
335 : 120

75
132
200

37
75
100
252

146

230 460
460
50/60
110/230

222 x 420 x 195


15

2
380

20.610.32-450

NZM7-200N

174 A : AC-53a :
335 : 9910
174 A : AC-53b :
335 : 120

90
160
250

45
90
125
301

174

230 460
460
50/60
110/230

520 x 338 x 248


15.7

2
452

Vertical
Vertical
IP20
IP20
Finger and back-of-hand proof

25 to +55 C

IEC/EN 60 947-4-2

DM4-340-75K

Moeller HPL0213-2001/2002

IEC/EN 60 947-4-2
IEC/EN 60 947-4-2
IEC/EN 60 947-4-2
IEC/EN 60 947-4-2
Damp heat, constant to IEC 60 068-2-3; damp heat, cyclical to IEC 60 068-2-30
0/40 C, to 60 C with a current reduction of 2 % per C
25 to +55 C
25 to +55 C
25 to +55 C
25 to +55 C
0 1000 m, up to 2000 m with a current reduction of 1 % per 100 m
Vertical
Vertical
Vertical
Vertical
IP20
IP20
IP20
IP20
Finger and back-of-hand proof
Finger and back-of-hand proof

DM4-340-11K

Technical Data

IEC/EN 60 947-4-2
IEC/EN 60 947-4-2
IEC/EN 60 947-4-2
IEC/EN 60 947-4-2
Damp heat, constant to IEC 60 068-2-3; damp heat, cyclical to IEC 60 068-2-30
0/40 C, to 60 C with a current reduction of 2 % per C
25/+55
25/+55
25/+55
25/+55
0 1000 m, up to 2000 m with a current reduction of 1 % per 100 m
Vertical
Vertical
Vertical
Vertical
IP20
IP20
IP20
IP20
Finger and back-of-hand proof
Finger and back-of-hand proof

DM4-340-7K5

Moeller HPL0213-2001/2002

13/021

DM4 Soft Starters

DM4 Soft Starters

Band
Tightening torque
Screwdriver
Control circuit
Current consumption of inputs
Digital inputs
Analog inputs
Pick-up voltage
DC-operated
AC-operated
Drop-out voltage
DC-operated
AC-operated
Programmable relay outputs
Number
Max. voltage
Max. current
Programmable analog outputs
Number
Voltage range
Max. current load rating
Programmable analog inputs
Ref 1
Ref 2
Soft start functions
Ramp times
Acceleration
Deceleration
Start pedestal
Voltage drop at stop [V]
Kickstart
Voltage
Duration
50 Hz
60 Hz
Current limitation

Band
Tightening torque
Screwdriver
Control cables
Solid
Flexible with ferrule
Stranded
Solid or stranded

Solid or stranded

Flexible with ferrule/


with cable lug
Stranded/with cable lug

Terminal capacities
Cable lengths
Connection
Solid

Technical Data

13/022

0 to +3
0 to 3

4
250
3 A, AC-11

2
0 10
10

24/0.45; 230/4.5
10/1

+24 to +230
24 to 230

0 to +3
0 to 3

4
250
3 A, AC-11

2
0 10
10

0 10
4 20

1 255
0 255
10 % 60 %
0 % 100 %

60 % 90 %

200 800
166 664
1 8 x Ie

V/mA
V/mA

V DC
V AC

V DC
V AC

V AC

V DC
mA

V DC
mA

s
s
V
V

ms
ms
A

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

mm2
mm2
mm2
Min. AWG
Max. AWG
Max.
Nm
Size

Nm
mm

Min. AWG
Max. AWG

mm2

mm2

1 x (1.5 16)
2 x (1 4)
1 x (1 16) /
2 x (1 4) /
1 x (2.5 25) /
2 x (2.5 4) /
12
4

1.2
0.8 x 4

DM4-340-11K

1 x (1.5 16)
2 x (1 4)
1 x (1 16) /
2 x (1 4) /
1 x (2.5 25) /
2 x (2.5 4) /
12
4

1.2
0.8 x 4

mm2

DM4-340-7K5

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

1 x (1.5 16)
2 x (1 4)
1 x (1 16) /
2 x (1 4) /
1 x (2.5 25) /
2 x (2.5 4) /
12
4

1.2
0.8 x 4

DM4-340-15K

Moeller HPL0213-2001/2002

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

1 x (1.5 16)
2 x (1 4)
1 x (1 16) /
2 x (1 4) /
1 x (2.5 25) /
2 x (2.5 4) /
12
4

1.2
0.8 x 4

DM4-340-22K

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

1 x (4 35)
2 x (4 10)
1 x (6 35) /
2 x (6 10) /
1 x (10 50) /
2 x 10 /
10
1

2.5
1.2 x 6.5

DM4-340-30K

Technical Data

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

1 x (4 35)
2 x (4 10)
1 x (6 35) /
2 x (6 10) /
1 x (10 50) /
2 x 10 /
10
1

2.5
1.2 x 6.5

DM4-340-37K

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

10
250 MCM
6 x 16 x 0.8
12

10
250 MCM
6 x 16 x 0.8
12

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

/ 50 120

/ 35 95

DM4-340-55K

/ 50 120

/ 35 95

M8 screws for cable lug

DM4-340-45K

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

10
250 MCM
6 x 16 x 0.8
12

/ 50 120

/ 35 95

M8 screws for cable lug

DM4-340-75K

Moeller HPL0213-2001/2002

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

10
250 MCM
6 x 16 x 0.8
12

/ 50 120

/ 35 95

DM4-340-90K

13/023

DM4 Soft Starters

DM4 Soft Starters

Type 2 coordination, in addition

Short-circuit strength
Type 1 coordination

AC-53b (with bypass)

Pollution degree
Power dissipation at
rated operational current Ie
Dimensions (W x H x D)
Weight
Main conducting paths
Rated operational voltage Ue
Rated insulation voltage Ui
Mains frequency
Control section power supply
Rated operational current Ie
AC-53
Assigned motor rating
(standard connection)
230 V
400 V
460 V
Phase current
(in-delta connection)
Assigned rating
(in-delta connection)
230 V
400 V
460 V
Overload cycle to
IEC/EN 60 947-4-2
AC-53a (without bypass)

General
Standards
Climatic proofing
Ambient temperature
Storage temperature
Altitude
Mounting position
Degree of protection
Protection against accidental contact

Technical Data

13/024

242 A : AC-53a :
335 : 6010
242 A : AC-53b :
335 : 360

55
110
150
349

110
160
250

202 A : AC-53a :
335 : 6010
202 A : AC-53b :
335 : 360

kW
kW
HP
A

kW
kW
HP

20.610.32-450

NZM7-200N

132
200
350

202

20.610.32-500

NZM7-250N

75
132
200
419

242

20.610.32-500

NZM10-400N/ZM-400

300 A : AC-53a :
335 : 603
300 A : AC-53b :
335 : 360

160
250
400

90
160
250
519

300

230 460
460
50/60
110/230

20.610.32-630

NZM10-400N/ZM-400

370 A : AC-53a :
335 : 603
370 A : AC-53b :
335 : 360

200
315
500

110
200
300
640

370

230 460
460
50/60
110/230

20.630.32-900

NZM10-630N/ZM-630

500 A : AC-53a :
335 : 603
500 A : AC-53b :
335 : 360

250
400
600

132
250
400
866

500

230 460
460
50/60
110/230

20.630.32-900

NZM10-630N/ZM-630

600 A : AC-53a :
335 : 603
600 A : AC-53b :
335 : 360

315
560
850

160
315
500
1039

600

230 460
460
50/60
110/230

640 x 610 x 375


65

20.630.32-1250

NZM14-800S

750 A : AC-53a :
335 : 603
750 A : AC-53b :
335 : 360

400
750
1100

200
400
600
1299

750

230 460
460
50/60
110/230

640 x 610 x 375


72

20.630.32-1250

NZM14-1000S

900 A : AC-53a :
335 : 603
900 A : AC-53b :
335 : 360

500
900
1300

250
500
750
1558

900

230 460
460
50/60
110/230

640 x 610 x 375


72

2
2775

230 460
460
50/60
110/230

640 x 610 x 375


56

2
2106

230 460
460
50/60
110/230

338 x 520x 248


22

2
1705

V AC
V AC
Hz
V AC

338 x 520x 248


22

2
925

338 x 520x 248


22

2
795

338 x 520x 248


15.7

DM4-340-500K

mm
kg

DM4-340-400K

2
1371

DM4-340-315K

2
662

DM4-340-250K

2
545

DM4-340-200K

DM4-340-160K

IEC/EN 60 947-4-2
IEC/EN 60 947-4-2
IEC/EN 60 947-4-2
IEC/EN 60 947-4-2
Damp heat, constant to IEC 60 068-2-3; damp heat, cyclical to IEC 60 068-2-30
0/40 C, to 60 C with a current reduction of 2 % per C
25 to +55 C
25 to +55 C
25 to +55 C
25 to +55 C
0 1000 m, up to 2000 m with a current reduction of 1 % per 100 m
Vertical
Vertical
Vertical
Vertical
IP20
IP20
IP20
IP20
Finger and back-of-hand proof
Finger and back-of-hand proof

DM4-340-132K

Technical Data

IEC/EN 60 947-4-2
IEC/EN 60 947-4-2
IEC/EN 60 947-4-2
IEC/EN 60 947-4-2
Damp heat, constant to IEC 60 068-2-3; damp heat, cyclical to IEC 60 068-2-30
0/40 C, to 60 C with a current reduction of 2 % per C
25 to +55
25 to +55
25 to +55
25 to +55
0 1000 m, up to 2000 m with a current reduction of 1 % per 100 m
Vertical
Vertical
Vertical
Vertical
IP20
IP20
IP20
IP20
Finger and back-of-hand proof
Finger and back-of-hand proof

DM4-340-110K

Moeller HPL0213-2001/2002

Moeller HPL0213-2001/2002

13/025

DM4 Soft Starters

DM4 Soft Starters

Band
Tightening torque
Screwdriver
Control circuit
Current consumption of inputs
Digital inputs
Analog inputs
Pick-up voltage
DC-operated
AC-operated
Drop-out voltage
DC-operated
AC-operated
Programmable relay outputs
Number
Max. voltage
Max. current
Programmable analog outputs
Number
Voltage range
Max. current load rating
Programmable analog inputs
Ref 1
Ref 2
Soft start functions
Ramp times
Acceleration
Deceleration
Start pedestal
Voltage drop at stop [V]
Kickstart
Voltage
Duration
50 Hz
60 Hz
Current limitation

Tightening torque
Control cables
Solid
Flexible with ferrule
Stranded
Solid or stranded

Band
Copper rail

0 to +3
0 to 3

4
250
3 A, AC-11

2
0 10
10

24/0.45; 230 V/4.5


10/1

+24 to +230
24 to 230

0 to +3
0 to 3

4
250
3 A, AC-11

2
0 10
10

0 10
4 20

1 255
0 255
10 % 60 %
0 % 100 %

60 % 90 %

200 800
166 664
1 8 x Ie

V/mA
V/mA

V DC
V AC

V DC
V AC

V AC

V DC
mA

V DC
mA

s
s
V
V

ms
ms
A

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

+24 to +230
24 to 230

24/0.45; 230 V/4.5


10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

mm2
mm2
mm2
Min. AWG
Max. AWG

Nm
Size

12

12

Nm

2 x 1/0
2 x 250 MCM
2 x (6 x 16 x 0.8)

2 x 1/0
2 x 250 MCM
2 x (6 x 16 x 0.8)

Min. AWG
Max. AWG
Max.

Solid or stranded

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230 V/4.5


10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

12

2 x 1/0
2 x 250 MCM
2 x (6 x 16 x 0.8)

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230 V/4.5


10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

12

2 x 1/0
2 x 250 MCM
2 x (6 x 16 x 0.8)

2 x (50 120)

2 x (35 95)

2 x (50 120)

2 x (50 120)

mm2

Stranded/with cable lug

2 x (50 120)

2 x (35 95)

2 x (35 95)

2 x (35 95)

mm2

DM4-340-200K

Flexible with ferrule

DM4-340-160K

M8 screws for cable lug

DM4-340-132K

M8 screws for cable lug

DM4-340-110K

Moeller HPL0213-2001/2002

mm2

Terminal capacities
Cable lengths
Connection
Solid

Technical Data

13/026

DM4-340-315K

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

24

2 x 2/0
2 x 500 MCM
2 x (10 x 21 x 1)
30 x 10

2 x (70 240)

2 x (50 240)

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

24

2 x 2/0
2 x 500 MCM
2 x (10 x 21 x 1)
30 x 10

2 x (70 240)

2 x (50 240)

2 x M12 screws for cable lug

DM4-340-250K

Technical Data

DM4-340-500K

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

45 x 20; 60 x 10;
80 x 10
24

200 800
166 664
1 8 x Ie

60 % 90 %

1 255
0 255
10 % 60 %
0 % 100 %

0 10
4 20

2
0 10
10

4
250
3 A, AC-11

0 to +3
0 to 3

+24 to +230
24 to 230

24/0.45; 230/4.5
10/1

1 x (0.75 2.5)
1 x (0.75 2.5)
1 x (0.75 2.5)
22
12

0.5
0.6 x 3.5

45 x 20; 60 x 10;
80 x 10
24

2 x M12 screws for rail connection

DM4-340-400K

Moeller HPL0213-2001/2002

13/027

DM4 Soft Starters

Technical Data

Moeller HPL0213-2001/2002

Technical Data

Moeller HPL0213-2001/2002

DM4 Soft Starters

DM4 Soft Starters

13/028

Moeller HPL0213-2001/2002

Dimensions

290

275

DM4-340-7K5
DM4-340-11K
DM4-340-15K
DM4-340-22K
DM4-340-30K
DM4-340-37K

125

195

222

420

DM4-340-45K
DM4-340-55K
DM4-340-75K
400

195

125
222

520

500

DM4-340-90K
DM4-340-110K
DM4-340-132K
DM4-340-160K
DM4-340-200K

250

248

338

250

250

375

640

LCD keypad for DM4


DE4-KEY-2

60

8.5

610

570

DM4-340-250K
DM4-340-315K
DM4-340-400K
DM4-340-500K

73.5

DM4 Soft Starters

DM4-340...

18

Вам также может понравиться