Вы находитесь на странице: 1из 2

Fagor 8020

NCnet 7.0 settings


Set these parameters on the machine
Select 9 Special Modes, then 1 General Parameters, and set the following parameter P000 = Peripher. Baud-Rate - 9600 P001 = Number of Bits 7 P002 = Parity - 2- Even P003 = Stop Bits - 2 Note: - After changing the parameter reset the control.

Set these parameters on the PC


Machine details
Machine name Control system Machine ID Communication Channel Port Number Folder for PC to Machine transfer Folder for Machine to PC transfer Baud rate Data bits Parity Stop bits Handshake MCH-1 Fagor 8010 01 Serial Port Any free COM port Transmit directory Receive directory 9600 7 Even 2 Software

General settings Ignore this. Leave all data as it is. Transmit settings
Wait period at start of transmission Wait period after transmitting program Size of transmit packet Delay period after each packet Wait for XON before transmitting program Transmit comments? Comment start character Comment end character Translation mode for CR Translation mode for LF Acknowledgement and error (Mode of transmission) ACK/ERR Message start text ACK/ERR Message end text Filter Null Character 10.00 5.0 0 0 No Yes ( ) Transmit as CR Transmit as LF Transmit descriptive message %7 M30 % Yes

Page 1 of 2

NC Program settings Program start string Program end string Characters to transmit at start Characters to transmit at start Receive settings
Wait period before receiving program Wait period after receiving program Transmit XON before transmitting program Auto compare and save Acknowledgements and errors Translation mode for CR Translation mode for LF Ignore control characters other than CR-LF Save Program between Start Characters and End Characters Start Program reception after these characters are received End Program reception after these characters are received 45.0 5.0 No Yes Transmit descriptive messages Ignore Save as CRLF Yes No

Number of Characters Number of Characters

To set the PC in the Drip-feed mode Drip feed is not available on this controller.

Cable connections
If the PC has 9 pin connector
Null modem Full Handshake

PC 9 pin 1 2 3 4 5 6 7 8

CNC 25 pin 8 2 3 20 7 6 4 5

PC 9 pin 1 2 3 4 5 6 7 8

CNC 25 pin 8 2 3 6 7 20 5 4

If the PC has 25 pin connector


Null modem Full Handshake

PC 25 pin 8 2 3 20 7 6 4 5

CNC 25 pin 8 3 2 20 7 6 4 5

PC 25 pin 8 2 3 20 7 6 4 5

CNC 25 pin 8 3 2 6 7 20 5 4

Page 2 of 2