Put on safety belt when you are working on a high place , and have your tools
secured.
!
#se safety guide line while loading or unloading big si$e or heavy loads.
*$+ ,- . ! /
%
&heck the eye wash table and *&+( each shift change.
:;< =>?@ABC
1,, *et a sign board and inform the driller when you do something repairing.
D EF GH
11, Hot work and cold work need to inform the foreman on duty, only can start the
work after got the foreman
s permission.
I J+KL D G < MNOPQ RSTU V
12, (ll flammable and harmful material should be stored separately and identified
clearly.
12WX@2YZ[ \ ]^ _
1-, wear ear plug while working in or around generator house.
NL` +ab c
14, check the fire e.tinguisher monthly and recorded.
de JC
1, shut down the engine and cut off the power first should the engine house on fire.
fgL`hJ iKL j k
1", (ll e/uipment, warehouse, living room should be grounded.
12 `l` ;m
1%, 0ach sling and wire rope should have an uni/ue identified mark on it, and
checked monthly.
dfn# 2o - de
1', 1ull o.ygen bottles should be stored separately with empty ones, and be shield.
\ ]^p q
1), 2o obstacle around escape line and the touchdown place should be clear and
soft.
rs t U2uv.wm x y .
2,, (ll personal include the third party should be know the location of safe brief area.
(nd how to react should emergency situation appears.
12z {|} ~ -5 N
21, 3e have two safe brief area. one at the entrance of rig site, another at the e.it.
2 f N f N
22, +e ware of H2* , we are drilling through H2* bearing formation.
H2*
H2*
m
2-, 3e have H2* and flammable gas detecting system on rigsite. 4he sensor are
located at shale shake, cellar, wellhead, and rig floor.
2
H2*
@X ! N $ $@ ?
24, 3hen the H2* comes out of hole under 1,ppm, the amber light will be on but the
horn silence. 3hen the H2* goes more than 2,ppm, the warning horn will sound and
the amber light will be on at the same time.
H2*
N
1,ppm
H2*
2,ppm
2, 4he driller is authori$ed to shut in the well when situation indicates.
fg H 2
2", (ll personal on rigsite should go /uickly to the safe brief area up the windy when
H2* alarm sounds.
H2*
12z P
2%, (ll personal should report to toolpusher upon entere the rigsite
12z fg <
2', 3hen conduct fire drill the members on duty are divided into two groups, fire
team and back up team.
<z \ J @S
2), 5nce somewhere set on fire, find out the fire source and the reason, report to
foreman immediately, then take proper way to put out fire.
fgwJ i Jk@J M RS- -~ J
-,, 2ever use water to put out fire when power didn6t cut off.
kj U' J
-1, (ll personal should take training and get necessary certificated before taking the
7ob.
12z OI-
-2, 3e will conduct function test first after +5P set up. 4hen pressure test pipe rams,
annular, choke manifold, inner +5P, chock line and kill line separately.
C Si VU S $U$ $ $
$ \
--, 8nner +5P include inside +5P, full open valve, upper Kelly cock, and Kelly cock.
{| $ $~ 3
-4, 0ach valve in choke manifold should be labeled with its normal position.
- o - 5
-, Pressure test didn6t go more than 4 ob7ects each time.
fU
4
-", 0ach ob7ects no matter rams, annular, inner +5P, or H&9, plate valve must pass
high pressure:2,,psi; and low pressure:-,,psi; test.
df $U$ $ $
2,,psi
@
-,,psi
-%, 4he low pressure will hold stably for mins, the high pressure will hold stably for
1,mins.
\
1,
\
-', 3e use clean water to perform pressure testing.
'
-), ( pressure test chart will be needed with e.plaining on it and handed in foreman.
V\: M
4,, 3e need to set a plug in casing head in order to change the pipe rams.
N C
41, 4he pressure test table plays an important role, so we must keep it in good
condition always.
? *'
42, (ll plate valve are float seal, so after you close a valve, be sure back /uarter of
turn.
12 1 Sf8
1<4
4-, &heck the hydraulic control line fre/uently= no leaks in system.
! V ! y
44, 4he four>way control handle should be either in open or in close but in neutral. *o
people can easily know the +5P6s working situation.
5G ) p 5 p 5 p5 zf>4
U
+5P
-
4, 3hat is the different between H2* drill and +5P drill?
H2*
+5P
-N
4", 4here are two mainly different, 1irst the signal, H2* giving off amber light and
sound, but the +5P using rig air horn
"
1, (@@ gas cylinders should be marked, secured, and shield.
12 2 $ 9$
2, power cables to trailers from light plant suspended or otherwise protected from
vehicle traffic.
L`P `- + !
-, protective covers on all lights.
o 2
4, (+& fire e.tinguisher in or outside each trailer.
` 2 - JCZ
, smoke alarm present and functioning in each room.
` 2 C
", electrical 7unction bo.es identified and kept in closed position.
; 2
%, electrical outlet labeled, voltage identified.
k
', electrical cords, plugs, receptacles etc in good condition.
12 $ $ y " "
), (ll pressure gauges in good condition and reliable.
12- $
",, fans and belts guarded.
$ 2 #
"1, (ll connections of pressure hose safely secured.
- ;5
"2, 1loors and e/uipment free of oil or grease
?@ y
"-, Aoghouse housekeeping acceptable, no accumulations that present a ha$ard.
<` s y .
"4, 2oise ha$ard sign in place= hearing protection provided and used by workers.
N2 -m~2 Y E c'z&' $ $
",BH8!H C5@4(!0>#*0 25 3(409Dsign posted in generator house.
`
B
'
D
EF
"", 0mergency lighting should be installed in *&9 room
`
"%, 2on>conductive mats placed on floor in *&9 room.
`
"', &52 fire e.tinguisher available in *&9 room.
`
&52
JCZ
"), *hear blind<blind rams control guarded.
j $)2 #
%,, +5P elastomers stored in air conditioned room.
+5P
]^N `
%1, 3ear goggles,apron,and rubber glovers when adding materials into mud.
[ $ $ )
%2, Eotors on mud tank are e.plosion>proof,
- L-
%-, 4he +5P stack should be properly turnbuckled, and make it tighten and centered.
C ' &
%4, &ellar protected from workers falling into it.
z
%, C>door closed or chained when not in use.
* &' +'
%", 1loor openings covered when not in use.
?- &'
%%, walkways and work area unobstructed, and clean.
@ 2uv. %
%', Handles for Kelly cocks and stabbing valve in easily accessible place.
~ 3)@ ^NWP-m~ &
%), Ariller6s controls ade/uately labeled and guarded.
H ? E 2
',, swivel used on tugger line.
'1, ma.imum allowable casing pressure posted at remote chocke control panel.
o*Q
'2,(ll drill procedure posted on wall of doghouse.
12 !" N <`
'-,3orkers stand out of the way when rolling,loading,or unloading
pipe.
@ z #N V~R
'4,1ire hose not used for any other purpose than fighting
fires,drills,or testing.
$ J$ $ RU ' '
',Hand held power tools have auto>shutoff devices.
) L% 2 KL
'",pneumatic power tools are secured to the air line to prevent accidental
disconnection.
R 2 z (
'%, 2o welding or cutting on load handling tools or e/uipment.
&,-+ U V '
'', *uper sacks handling system certified and inspected regularly.
*(# ! V 8 8)
'), *afety instruction given to all personnel entering location.
-z V~*-+
),, 0mployees should know location of stretcher and blankets.
, @- N ) *
)1, (ll working surfaces higher than 4 feet have standard handrails.
*p
4
2 ( 3
)2, 3indsocks or streamers visible from anywhere on the location.
- .UP +/0 !
)-, 1lare ignition system available and in good condition.
J U