POSITIVE DISPLACEMENT PUMPS - ROTARY

MAY 1984

PAGE 1 OF 10

EGE 15-B-2 1984

TABLE OF CONTENTS 1. 2. 3. Scope References General 4. Modifications to API Standard 676

Appendix Materials Tables

1.

SCOPE

This Guide covers the basic requirements for rotary positive displacement pumps and related auxiliary equipment. 2. REFERENCES

The following publications form a part of this Guide. Unless otherwise specified herein, use the latest edition.
Mobil Engineering Guides EGE 00-B-5 EGE 00-B-20 EGE 00-C-4 EGE 15-D-2 EGE 15-B-7 EGE 33-B-9 Equipment Noise Control Pressure Casting Inspection Equipment Purchases - General Engineering Requirements Rotary Pump Data Sheet (a and b) General-Purpose Steam Turbines Electrical Induction Motors

AGMA (American Gear Manufacturers Association) Standard 420.04 Practice for Enclosed Speed Reducers or Increasers Using Spur, Helical, Herringbone and Spiral Bevel Gears

ANSI (American National Standards Institute) Standards B16.1 B16.5 Cast Iron Pipe Flanges and Flanged Fittings Pipe Flanges and Flanged Fittings, Steel Nickel Alloy and Other Special Alloys

API (American Petroleum Institute) Standards Std 610 Std 676 Centrifugal Pumps for General Refinery Services Positive Displacement Pumps Rotary

ASME (American Society of Mechanical Engineers) Standard B31.3 Chemical Plant and Petroleum Refinery Piping

MOBIL ENGINEERING GUIDE EGE 15-B-2 1984


HI (Hydraulic Institute) Standards Rotary Pump Section
PAGE 2 OF 10 MAY 1984

3.

GENERAL

3.1 Pumps and auxiliaries shall conform to API Standard 676 except as modified in Section 4 of this Guide. 3.2 The vendor shall furnish the pump, driver, gear reducer (if required), couplings, guards, and baseplate in accordance with this Guide, EGE 15-D-2, and the Project Specifications. The vendor shall be responsible for the guarantee and overall performance of the pump, driver, and auxiliaries. 3.3 If two or more pumps are purchased for the same conditions, the parts including those of the subassemblies shall be interchangeable. 3.4 4. The vendor shall comply with the requirements of EGE 00-C-4 except as modified herein. MODIFICATIONS TO API STANDARD 676

The following items are amendments to API Standard 676. The section and paragraph numbers refer to those used in that standard.
SECTION 2 BASIC DESIGN

Paragraph 2.1.2 (Substitution)


Equipment covered by this Guide shall meet the applicable noise levels established in EGE 00-B-5, preferably without the use of acoustic enclosures. If acoustic enclosures are required, the vendor shall include data and cost in the proposal.

Paragraph 2.1.4 (Modification)


Delete the words "when specified by the purchaser."

Paragraph 2.1.6 (Addition)


Casing sections or covers shall be fitted with jack-screws to facilitate dismantling.

Paragraph 2.1.7, First Sentence (Substitution)


All equipment shall be suitable for installation outdoors, where it will be exposed to the plant atmosphere and the full range of ambient and unusual environmental conditions specified on EGE 15-D-2.

Paragraph 2.2.2 (Substitution)


The maximum allowable working pressure of the entire pump, suction, and discharge shall be at least equal to the discharge pressure relief valve setting plus 15% accumulation.

Paragraph 2.2.3 (Substitution)


The pump speed recommended by the vendor shall be subject to Mobil approval. High linear velocities with unnecessarily high fluid velocities shall be avoided in the interest of less frequent maintenance, low noise, and NPSH considerations.

MOBIL ENGINEERING GUIDE


MAY 1984 PAGE 3 OF 10

EGE 15-B-2 1984

Paragraph 2.3.3 (Modification)


Change of alignment permitted in this paragraph shall be limited to 25.4 m (1 mil).

Paragraph 2.3.10 (New Paragraph)


When specified, heating jackets shall be provided to heat the pump and packing glands. Heating jackets shall be suitable for the conditions indicated on EGE 15-D-2.

Paragraph 2.4.1 (Substitution)


The inlet connection shall be rated for the same maximum working pressure as the outlet connection, both being rated for the maximum allowable working pressure specified in Paragraph 2.2.2 of this Guide. Threaded connections 11/2 in. nominal pipe size (NPS) and smaller are subject to Mobil approval. Where welding of screwed connections is necessary, the preparation and welding shall be in accordance with Paragraph 2.4.5 of this Guide.

Paragraph 2.4.4 (Modification)


Exceptions to ANSI B16.1 or B16.5 are as specified in Paragraph 2.4.4.3 as modified in this Guide.

Paragraph 2.4.4.2 (Delete) Paragraph 2.4.4.3 (Modification)


Add "subject to Mobil approval."

Paragraph 2.4.4.4 (Substitution)


When connections differ from those covered by ANSI, they must be clearly indicated by the vendor and are subject to Mobil approval. Non-standard mating parts extend the spares inventory and are not normally considered acceptable to the purchaser. Such nonstandard parts shall be identified by the vendor prior to purchase.

Paragraph 2.4.5 (Addition)


Threaded connections less than 1/2 in. NPS are not acceptable. Seal welds at screwed connections shall cover all exposed threads in accordance with ASME B31.3. Weld preparation detail is subject to Mobil approval.

Paragraph 2.4.6 (Substitution)


All casing vent, drain, or gage connections shall be in accordance with Mobils specified piping standards unless specifically agreed otherwise.

Paragraph 2.5.2, First Sentence (Substitution)


Change 110 percent to 115 percent.

Paragraph 2.5.3 (Addition)


Pumps handling nonlubricating fluids or heavy oil shall be fitted with external bearings and timing gears.

MOBIL ENGINEERING GUIDE EGE 15-B-2 1984


PAGE 4 OF 10 MAY 1984

Paragraph 2.6.3.2 (Addition)


All metal parts of seals, other than the seal plate and seal ring (or seat), shall be Type 316 stainless steel unless otherwise specified on EGE 15-D-2.

Paragraph 2.6.3.4 (Modification)


The vendor shall provide for the circulation of clean fluid to the mechanical seal faces unless otherwise specified. Restricting orifices, if used, shall not be less than 3.2 mm (1/8 in.).

Paragraph 2.6.3.6 (Modification)


Mechanical seals shall be installed in the pump during all specified tests.

Paragraph 2.6.3.7 (New Paragraph)


Mechanical seals shall be hydraulically balanced for sealing pressures above 517 kPa gage (75 psig).

Paragraph 2.6.4.3, First Sentence (Modification)


Delete the words "when specified by the purchaser or recommended by the vendor" and substitute "when required."

Paragraph 2.6.4.6 (New Paragraph)


Gland bolts shall be steel or steel alloy unless otherwise specified.

Paragraph 2.7.1 (Substitution)


Bearing type shall be selected for the specific service indicated on EGE 15-D-2. Anti-friction bearings, if used, shall be retained on the shaft and fitted into the housings in accordance with the methods and procedures contained in Anti-Friction Bearing Manufacturers Association (AFBMA) publications. A drain plug shall be provided at the bottom of each bearing.

Paragraph 2.7.2 (Addition)


The recommended oil level shall be clearly and durably marked on the outside of the bearing housing.

Paragraph 2.7.4 (Substitution)


Anti-friction bearings, if used, shall be designed for an AFBMA L-10 rated life of 25,000 hours continuous duty at rated load and speed. (The rated life is the number of hours at rated bearing load and speed that 90 percent of a group of identical bearings will complete or exceed before the first evidence of a failure.)

Paragraph 2.7.5 (New Paragraph)


External bearings shall be so located and arranged that the shaft packing can be renewed without dismantling any part of the pump other than the packing gland. The bearings shall be arranged so that minimum dismantling is required to renew mechanical seals. The design of pumps that incorporate timing gears shall be such that correct meshing of the gears is ensured when they are replaced after being removed to renew a mechanical seal. Gears shall be manufactured in accordance with AGMA practice.

Paragraph 2.8.1 (Substitution)

MOBIL ENGINEERING GUIDE


MAY 1984 PAGE 5 OF 10

EGE 15-B-2 1984

The bearing lubrication shall be selected for the service indicated on EGE 15-D-2. The vendor shall specify the following: (1) the amount and frequency of lubrication for separately lubricated bearings and timing gears; (2) the Mobil equivalent lubricant.

Paragraph 2.8.2 (Modification)


Delete "when specified by the purchaser."

Paragraph 2.8.2 (Addition)


Constant-level oilers shall be positively locked against rotation in the bearing housing.

Paragraph 2.9.1.1 (Substitution)


Casings shall be made of steel or alloy steel if the pumps handle liquids under any of the following conditions: 1. Pumping temperature, 177C (350F) and higher. 2. Maximum discharge pressure, 1724 kPa gage (250 psig) and higher. 3. Flammable or toxic liquids with vapor pressure greater than 97 kPa absolute (14 psia), measured at pumping temperature or at 38C (100F), whichever is higher. 4. Flammable or toxic liquids with specific gravity less than 0.825 at pumping temperature, together with a maximum discharge pressure in excess of 1034 kPa gage (150 psig). 5. Hydrocarbon within battery limits of process units, lube blending facilities, and lube oil and seal oil systems. 6. When stated on the data sheet.

Paragraph 2.9.1.5 (New Paragraph)


Tables A-1 and A-2 of this Guide replace Appendix B of API Standard 676.

Paragraph 2.9.2.2, Second Sentence (Substitution)


Chaplets, if used, shall be clean, rust free, and of a composition equivalent to the casting. Any chaplet not completely fused into the pressure casting shall be replaced by weld metal equivalent to the casting composition.

Paragraph 2.9.2.5 (New Paragraph)


Proposed repair welds to alloy steel cases shall be submitted for Mobil approval before the repairs are made.
SECTION 3 ACCESSORIES

Paragraph 3.1.4, First and Second Sentences (Substitution)


For motor-driven units, the motor horsepower requirements shall be the larger of the following: 1. Pump rated brake horsepower plus 25 percent for motors of 19 kW (25 hp) or below, plus 15 percent

MOBIL ENGINEERING GUIDE EGE 15-B-2 1984


PAGE 6 OF 10 MAY 1984

for 22 kW to 56 kW (30 hp to 75 hp) motors, plus 10 percent for motors of 75 kW (100 hp) and larger. 2. The horsepower required for continuous pump operation with total flow through the relief valve and a 15 percent accumulation when handling liquid with the highest specified viscosity.

Paragraph 3.1.5 (Substitution)


Motors drivers shall conform to Mobil specifications and EGE 33-B-9.

Paragraph 3.1.6 (Substitution)


Turbine drivers shall conform to Mobil specifications and EGE 15-B-7.

Paragraph 3.2.2 (Substitution)


Couplings shall be the forged steel, flexible spacer type. The spacer shall be of sufficient length to permit seal replacement without moving the pump or driver. If the coupling is not specified on EGE 15-D-2, the pump vendor shall give the manufacturer, size, and model description of the coupling in the proposal. When flexible disc couplings are proposed or specified, the discs shall be Type 301 stainless steel unless otherwise specified on the data sheet.

Paragraph 3.2.4 (New Paragraph)


The coupling shall be selected so that 75 percent of the manufacturers rating is not exceeded when the coupling is operated with a particular pump and driver at maximum operating conditions. In addition, hub bores shall not exceed the coupling manufacturers recommendations.

Paragraph 3.2.5 (New Paragraph)


When limited end float couplings are required, the resulting thrust shall be carried by the pump. The pump shall be designed to carry the thrust in addition to normal, startup, and shutdown loads.

Paragraph 3.3.1 (Substitution)


A continuous, self-supporting baseplate shall be provided. All equipment supports shall be directly and rigidly attached to the structural steel members of the baseplate by continuous welding. The top of the baseplate shall be covered with flat steel plate complete with a sufficient number of grout holes [minimum 102 mm (4 in.) diameter] readily accessible without removal of equipment. The grout holes shall be arranged so that oil will not accumulate over the open grout. The baseplate shall be of the raised-lip drain rim design.

Paragraph 3.3.3, Second Sentence (Substitution)


The baseplate and pump supports shall be so constructed as to limit angular and parallel misalignment during operation to the value specified in Paragraph 2.3.3 (Modification) of this Guide.

Paragraph 3.4.2 (Substitution)


Relief valves shall be set to operate at not more than the maximum working pressure of the casing but at not less than 115 percent of the rated discharge pressure or 172 kPa gage (25 psig), whichever is the higher.

Paragraph 3.4.3 (Substitution)

MOBIL ENGINEERING GUIDE


MAY 1984 PAGE 7 OF 10

EGE 15-B-2 1984

When fully open, relief valves shall be able to handle the rated capacity with pressure accumulation of not more than 10 percent above the set pressure.

Paragraph 3.5.7 (New Paragraph)


Pipe joining and connections shall be flanged, socket-welded, or seal-welded screwed piping. The connection to the mechanical seal end plates shall not be seal welded. A socket-weld union shall be provided for seal end plate removal. Flanged connections provided with the pump shall not show misalignment when disconnected after initial assembly.
SECTION 4 INSPECTIONS AND TESTS

Paragraph 4.2.3 (New Paragraph)


Inspection and repairs of pressure castings shall be in accordance with EGE 00-B-20.

Paragraph 4.3.3 (Substitution)


The manufacturer shall conduct a mechanical running test on all pumps for sufficient time to ensure satisfactory operation at the specified conditions for a minimum of one hour. Unless otherwise agreed in advance, the actual rated speed to be used in connection with tests of motor-driven pumps shall be the full-load speed, shown on EGE 15-D-2, applying to the specific driver that is furnished. If a witnessed test is specified, the manufacturer shall make a preliminary test run and complete all mechanical checks prior to inspection by Mobil. The manufacturer shall also be prepared to disconnect any flange joints to demonstrate proper piping alignment.

Paragraph 4.3.4.1 (Substitution)


Each pump shall be tested for performance in the manufacturers shop at its rated speed, capacity, and pressure. Test data shall be obtained and computed in accordance with the test code in Hydraulic Institute Standards, Rotary Pump Section. Test tolerances shall be as detailed in Paragraph 4.3.4.3 of API Standard 676. The liquid used during the performance test shall have a viscosity similar to that of the operating liquid. During testing, all parts of the pump shall operate without excessive heating of bearings or glands, vibration, or display of other unfavorable characteristics. If after shop test any modifications to the internals (bearings, seals, gears) of the pump are required, the test shall be repeated. A retest is also required when modification to noninternal components may affect pump performance.

Paragraph 4.4.2.1 (Modification)


Add "subject to Mobil review and approval of the manufacturers standards for paint and paint preparation procedures."
SECTION 5 GUARANTEE AND WARRANTY

Paragraph 5.1 (Substitution)


Unless a specific exception is accompanied by a description of the proposed substitution (recorded under "Exceptions" in the vendors proposal), it shall be mutually understood that the proposal is based on equipment that complies strictly with the requirements of this Guide, EGE 15-D-2, API Standard 676, and the applicable Project Specifications.
SECTION 6 VENDOR'S DATA

MOBIL ENGINEERING GUIDE EGE 15-B-2 1984


PAGE 8 OF 10 MAY 1984

Paragraph 6.2.1.2 (Substitution)


The vendor shall submit drawings for Mobil review before proceeding with manufacture.

Paragraph 6.2.2.1 (Substitution)


The vendor shall provide a completed EGE 15-D-2 "as built."

Paragraph 6.2.2.3 (Modification)


For "API data sheets" substitute EGE 15-D-2.

Paragraph 6.2.2.4 (Substitution)


Recommended spare parts, prices, and delivery date shall be submitted with the proposal. Stock items should be so noted.

MOBIL ENGINEERING GUIDE


MAY 1984 PAGE 9 OF 10

EGE 15-B-2 1984

MOBIL ENGINEERING GUIDE EGE 15-B-2 1984


PAGE 10 OF 10 MAY 1984

TABLE A-2 MISCELLANEOUS MATERIALS Material Ni-resist Precipitation-hardening steel Stellite Typical Description Type 1, 2, or 3 as recommended by International Nickel Co. for service conditions. Acceptable types include ARMCO 17-7 PH and 17-4 PH, stainless USS stainless W, Allegheny Ludlum AM 350 and AM 355. Overlay-weld deposit of 0.80 mm (1/32 in.) minimum finished
thickness of Stellite AWS, Class RCoCr-C, RCoCr-A, or equivalent. Solid cast Stellite No. 3 or equivalent may be substituted for an overlaid part. Colmonoy Sprayed or fused deposit of 0.24 mm (0.010 in.) or gas-weld deposit of 0.80 mm (1/32 in.) minimum finished thickness of Wall-Colmonoy AWS, Class RNiCr-C or equivalent. Suitable mechanical carbon as recommended by the mechanical seal manufacturer for the service. Long-fiber asbestos with synthetic rubber binder suitable for 399C (750F), or spiral-wound stainless steel and asbestos, or nonasbestos (Garlock or equivalent) as allowed by local safety codes. Teflon, Kel-F, or similar material. Kennametal K-6 (cobalt binder) or equivalent (solid part, not overlay). Kennametal K-801 (nickel binder) r equivalent (solid part, not overlay). Metco 31C, Wallex 55, or equivalent [sprayed overlay, minimum finished thickness of 7.62 mm (0.03 in.)]. DuPont Viton or equivalent. ASTM A744, CN7M; alloy 20 CB3 castings or forgings as applicable for

Carbon

Composition (gaskets)

Tetrafluoroethylene (TFE) Tungsten carbide-1 Tungsten carbide-2 Tungsten carbide-3

Fluoroelastomer Alloy 20 casings or shafts; or equivalent. Nitrile (Buna-N) FFKM elastomer Silicon carbide Graphite foil

B. F. Goodrich HYCAR or equivalent. ASTM D1418 FFKM elastomer, DuPont Kalrez, or equivalent. Carborundum KT or equivalent. Union Carbide Grafoil or equivalent.

MOBIL ENGINEERING GUIDE ROTARY PUMP DATA SHEET


SI (METRIC) UNITS ISSUE 1 2 APPLICABLE TO: FOR SITE SERVICE MANUFACTURER PROVIDED BY INQUIRY NO. APPROVED 3 ISSUE APPROVED JOB NO. P.O. NO. ITEM NO. REQ NO.

EGE 15-D-2a 1984


Page 1 of 2

4 PROPOSAL

PURCHASE

AS BUILT

DATE

REVISION UNIT SERIAL NO. NO. PUMPS REQUIRED NO. MOTORS REQUIRED SIZE AND TYPE MODEL

NOTE:

INDICATES INFORMATION TO BE COMPLETED BY PURCHASER API STANDARD 676 GOVERNS UNLESS OTHERWISE NOTED.

BY MANUFACTURER

OPERATING CONDITIONS (TO BE COMPLETED BY PURCHASER) Liquid Pumping Temperature, C: Normal Specific Gravity @ PT Vapor Pressure @ PT, kPa abs Viscosity @ PT, mPaCs: Maximum Electrical Area Hazard: Class Site Temperature, C: Normal Maximum Minimum Corrosion/Erosion Caused by REMARKS: Group Division Minimum Maximum Minimum Rated Capacity @ PT, m /min: @ Maximum Viscosity Discharge Pressure, kPa gage: Maximum Maximum Differential Pressure, kPa: Maximum NPSH Available, kPa Hydraulic kW Location: Minimum Rated Minimum Minimum Rated Rated Suction Pressure, kPa gage: @ Minimum Viscosity
3

F F

Indoor Outdoor

F F

Heated

Unheated

PERFORMANCE (TO BE COMPLETED BY MANUFACTURER) AT RATED CONDITIONS: NPSH Required, kPa Rated Speed, rpm Displacement, m /min REMARKS:
3

AT RATED CONDITIONS: Volumetric Efficiency, % Mechanical Efficiency, % Brake kW @ Maximum Viscosity Brake kW @ Relief Valve Setting Maximum Allowable Speed, rpm Minimum Allowable Speed, rpm

CONSTRUCTION (TO BE COMPLETED BY PURCHASER AND MANUFACTURER) Pump Type: Spur Gear Helical Gear Other

Casing: Maximum Allowable Pressure: Hydrostatic Test Pressure: Jacket Pressure: Rotor Mount: kPa gage @ kPa gage C

G G G

G G G

Twin-Screw Three-Screw

G G G

Nozzle Vane Progressing Cavity Suction Discharge Gland Flush Drains Vents Jacket Connection C

Size

Rating

Facing

Location

kPa gage @ Overhung

Between Bearings

Packing: Manufacturer and Type

No. of Rings

MOBIL ENGINEERING GUIDE ROTARY PUMP DATA SHEET


SI (METRIC) UNITS CONSTRUCTION (Contd)

EGE 15-D-2a 1984


Page 2 of 2

Timing Gears? Bearing Type:

Lubricant Type REMARKS:

G G G

G G

Yes Radial

Lubrication Type: Pumped Fluid External

G G

Ring Oil Oil Flood

G G G G

No Thrust

Oil Mist

Grease

API 610 Code Piping for Seal Flush Furnished by: Pump Vendor Others Piping for Cooling/Heating Furnished by: Pump Vendor Others

F G G F G F F

Mechanical Seals: Manufacturer and Model Manufacturer Code

API 610 Seal Flush Plan

F F

MATERIALS (TO BE COMPLETED BY MANUFACTURER) Casing Stator End Plates Rotor(s) Vanes Shaft Sleeve(s) Gland(s) Bearing Housing Timing Gears Baseplate REMARKS:

SHOP TESTS (TO BE COMPLETED BY PURCHASER) Test Hydrostatic Mechanical Run Performance Nonwitnessed

F F F F F G F G F

NPSH Shop Inspection

F F F F

Witnessed

F F F F

REMARKS:

Dismantle and Inspect After Test

Motor

Driver Data Sheet

Turbine

DRIVER (TO BE COMPLETED BY PURCHASER AND MANUFACTURER) Other rpm REMARKS:

kW @

Direct Coupled

Coupling Manufacturer

DRIVE MECHANISM (TO BE COMPLETED BY PURCHASER AND MANUFACTURER) Toothed Belt Drive

Variable Speed

REMARKS:

BASEPLATE (TO BE COMPLETED BY PURCHASER)

By Pump Manufacturer REMARKS:

F F F

Decking Open Beam Support Fully Grouted

Ungrouted

ADDITIONAL INFORMATION

MOBIL ENGINEERING GUIDE ROTARY PUMP DATA SHEET


CUSTOMARY UNITS ISSUE 1 2 APPLICABLE TO: FOR SITE SERVICE MANUFACTURER PROVIDED BY INQUIRY NO. APPROVED 3 ISSUE APPROVED JOB NO. P.O. NO. ITEM NO. REQ NO.

EGE 15-D-2b 1984


Page 1 of 2

4 PROPOSAL

PURCHASE

AS BUILT

DATE

REVISION UNIT SERIAL NO. NO. PUMPS REQUIRED NO. MOTORS REQUIRED SIZE AND TYPE MODEL

NOTE:

INDICATES INFORMATION TO BE COMPLETED BY PURCHASER API STANDARD 676 GOVERNS UNLESS OTHERWISE NOTED.

BY MANUFACTURER

OPERATING CONDITIONS (TO BE COMPLETED BY PURCHASER) Liquid Pumping Temperature, F: Normal Specific Gravity @ PT Vapor Pressure @ PT, psia Viscosity @ PT, (SSU) (cp): Maximum Electrical Area Hazard: Class Site Temperature, F: Normal Maximum Minimum Corrosion/Erosion Caused by REMARKS: Group Division Minimum Maximum Minimum Rated Capacity @ PT, US gpm: @ Maximum Viscosity Discharge Pressure, psig: Maximum Suction Pressure, psig: Maximum Differential Pressure, psi: Maximum NPSH Available, psi Hydraulic hp Location: Minimum Rated Minimum Rated Minimum Rated @ Minimum Viscosity

F F

Indoor Outdoor

F F

Heated

Unheated

PERFORMANCE (TO BE COMPLETED BY MANUFACTURER) AT RATED CONDITIONS: NPSH Required, psi Rated Speed, rpm Displacement, US gpm REMARKS: AT RATED CONDITIONS: Volumetric Efficiency, % Mechanical Efficiency, % bhp @ Maximum Viscosity bhp @ Relief Valve Setting Maximum Allowable Speed, rpm Minimum Allowable Speed, rpm

CONSTRUCTION (TO BE COMPLETED BY PURCHASER AND MANUFACTURER) Pump Type: Spur Gear Helical Gear Other

Casing: Maximum Allowable Pressure: Hydrostatic Test Pressure: Jacket Pressure: Rotor Mount: psig @ psig F

G G G

G G G

Twin-Screw Three-Screw

G G G

Nozzle Vane Progressing Cavity Suction Discharge Gland Flush Drains Vents Jacket Connection F

Size

Rating

Facing

Location

psig @ Overhung

Between Bearings

Packing: Manufacturer and Type

No. of Rings

MOBIL ENGINEERING GUIDE ROTARY PUMP DATA SHEET


CUSTOMARY UNITS CONSTRUCTION (Contd)

EGE 15-D-2b 1984


Page 2 of 2

Timing Gears? Bearing Type:

Lubricant Type REMARKS:

G G G

G G

Yes Radial

Lubrication Type: Pumped Fluid External

G G

Ring Oil Oil Flood

G G G G

No Thrust

Oil Mist

Grease

API 610 Code Piping for Seal Flush Furnished by: Pump Vendor Others Piping for Cooling/Heating Furnished by: Pump Vendor Others

F G G F G F F

Mechanical Seals: Manufacturer and Model Manufacturer Code

API 610 Seal Flush Plan

F F

MATERIALS (TO BE COMPLETED BY MANUFACTURER) Casing Stator End Plates Rotor(s) Vanes Shaft Sleeve(s) Gland(s) Bearing Housing Timing Gears Baseplate REMARKS:

SHOP TESTS (TO BE COMPLETED BY PURCHASER) Test Hydrostatic Mechanical Run Performance Nonwitnessed

F F F F F G F G F

NPSH Shop Inspection

F F F F

Witnessed

F F F F

REMARKS:

Dismantle and Inspect After Test

Motor

Driver Data Sheet

Turbine

DRIVER (TO BE COMPLETED BY PURCHASER AND MANUFACTURER) Other rpm REMARKS:

hp @

Direct Coupled

Coupling Manufacturer

DRIVE MECHANISM (TO BE COMPLETED BY PURCHASER AND MANUFACTURER) Toothed Belt Drive

Variable Speed

REMARKS:

BASEPLATE (TO BE COMPLETED BY PURCHASER)

By Pump Manufacturer REMARKS:

F F F

Decking Open Beam Support Fully Grouted

Ungrouted

ADDITIONAL INFORMATION