Академический Документы
Профессиональный Документы
Культура Документы
Column Operations
Workshop
In this module, you will simulate an Ethanol Plant. You will get more
practice with the Column unit operation of HYSYS by:
The feed to the Rectifier (Rect) is the bottoms product of the Lights
purification tower and the vapour draw from the concentration tower.
The Rectifier is operated as a conventional distillation tower.
2
Column Operations 3
Learning Objectives
Once you have completed this section, you will be able to:
Prerequisites
Before beginning this section, you need to be able to:
3
Process Overview
Column Operations 5
Column Overviews
CO2 Wash
Concentrator
Lights
5
6 Column Operations
Rectifier
6
Column Operations 7
Conditions
H2O 100%
7
8 Column Operations
Conditions
Ethanol 0.0637
H2O 0.8759
CO2 0.0601
Methanol 4.433e-5
1-Propanol 2.802e-5
2-Propanol 2.808e-5
1-Butanol 2.505e-5
3-M-1-C4ol 9.727e-5
2-Pentanol 2.457e-5
Glycerol 3.141e-5
Conditions
H2O 100%
8
Column Operations 9
Conditions
Inlets FromFerm
9
10 Column Operations
Column SubFlowsheet
A SubFlowsheet contains equipment and streams and exchanges
information with the Parent Flowsheet through the connected streams.
From the Main Environment, the Column appears as a single, multi-
feed multi-product operation. In many cases, you can treat the column
in exactly that manner.
10
Column Operations 11
Column Types
HYSYS has several basic Column Templates (pre-constructed column
configurations) which may be used for installing a new Column,
allowing HYSYS to model several different separation processes.
Initial Estimates
In order to calculate, the Column solver in HYSYS requires user-
supplied estimates ranging from condition parameters to feed and
draw locations. These data can be supplied in several ways. The first
interface when you select a Column requires values for the Number of
Trays, Reflux, Pressure, and so on. In the Column Solver, on the Work
Sheet tab, Conditions page, data can also be supplied. On the Design
tab, Specs page, HYSYS allows you to choose from a library of
specifications gathered in the Column Specification Types window,
activated when you press the Add button. Specification Types can be
supplied as Estimates or as Active specifications. Only Active
specifications fill the Degree of Freedom of the Column which must be
zero for the solver to calculate. Inactive specifications (Estimates) are
used only as initial estimates for the convergence algorithm and never
use a degree of freedom. Alternatively, Estimates can be supplied on the
Estimates page under the Parameters tab. However, they will not
appear on the Monitor, and hence cannot be set as Active
specifications.
If the user does not have initial estimates HYSYS generates them.
However for chemical systems, it is recommended to use the HYSYS
Estimate Generator tool. In the Column Environment, on the
Parameters tab, Solver page, there is the Initial Estimate Generator
11
12 Column Operations
Parameters box. By checking the box, the IEG will perform iterative
flash calculations to provide the initial estimates for the temperature
and composition profiles. No user estimates are required when the
Iterative IEG check box is activated.
The Input Expert will guide you through the installation of the column.
12
Column Operations 13
13
14 Column Operations
Concentrator
This tower removes most of the Methanol from the Fermentor
products.
Connections
No. of Stages 17
Pressure
Temperatures
However, in this case, we do not need a Draw Rate specification for this
stream; therefore, we need to replace the Draw Rate specification that
HYSYS added automatically with one that we will define to meet our
simulation needs.
14
Column Operations 15
15
16 Column Operations
This specification will set the ratio of ethanol recovered in the specified
stream compared to the amount of ethanol fed to the column. Here, we
have set this ratio at 0.95, meaning that 95% of the ethanol supplied to
the column is recovered in the Rect Feed stream.
We are not concerned about where the other 5% goes, although it must
exit the column in one of the other product streams.
16
Column Operations 17
Lights
The Lights Tower is a purification tower.
Add the Refluxed Absorber column and enter the following data.
No. of Stages 5
Not Required
Reflux Ratio 5
17
18 Column Operations
Stage Condenser
Component Ethanol
So, deactivate the Reflux Ratio specification and activate the Ethanol
Purity specification.
18
Column Operations 19
Rectifier
The primary product from a plant such as this would be the azeotropic
mixture of ethanol and water. The Rectifier serves to concentrate the
water/ethanol mixture to near azeotropic composition. The Rectifier is
operated as a conventional distillation tower. It contains a partial
condenser as well as a reboiler.
Connections
No. of Stages 59
Pressures
Specifications
19
20 Column Operations
We will add two Column Draw Rate specifications and one Component
Fraction specification.
1. Remember that when we added the two side draw streams to the
column, HYSYS automatically created Draw Rate specifications
for those streams. On the Monitor page, enter the following
values for these two Draw Rate specifications.
Specification 1 Specification 2
Component Ethanol
20
Column Operations 21
21
22 Column Operations
22
Column Operations 23
Optional Challenge
Replacing the Kettle Reboiler with a
Thermosyphon Reboiler
In this portion of the module, we will replace the default kettle type
reboiler on the Rectifier column with a "Thermosyphon" type reboiler.
Following the steps below will allow you to replace the standard kettle
reboiler with a thermosyphon type reboiler.
1. Change the number of stages in the column to 60. This value can
be accessed from the Connections page of the column’s property
viewer.
2. Enter the Column Environment by pressing the Column
Environment button on the property viewer.
3. Disconnect the "Stillage B" stream from the reboiler and reattach
it as a material withdraw stream from stage 60.
4. Disconnect the "Boilup" stream from stage 60 and reattach it to
stage 59. You will need to expand the trays shown by the column
icon in order to attach the stream to this tray. Right-click on the
tray section, and select Show Trays. Use the Radio button to
select Full Expansion, or scroll down and check to Show box for
stage 59.
5. Attach the reboiler’s liquid product outlet (formerly the location
of "Stillage B" stream) to the inlet point on stage 60.
23
24 Column Operations
Stage Reboiler
Note that adding the additional stage and modifying the reboiler has
not changed the operating behaviour of the column. The bottom stage
of the column (#60) does not function like a true equilibrium stage
(there is no contacting vapour from the bottom). The boil-up provided
by the thermosyphon reboiler will be the same as for the kettle reboiler.
This is independent of the reboiler type.
24