1/16/2014 Page 1 Project: ventilatii - cta Unit: Danvent DV80 Summary for unit no. 1, Danvent DV80 Unit size 80 Roof unit Unit width 2170 mm Weight 4566 kg Supply Extract Airflow (1,205 kg/m) 13280.40 m3/h 13280.40 m3/h Face velocity (unit) 1.54 m/s 1.54 m/s External pressure 382 Pa 436 Pa Filter F7 F7 Fan speed 1123 RPM 1091 RPM Motor 5.50 kW 4.00 kW Voltage 3x400 V 3x400 V Rated current 13.70 A 10.00 A Heat recovery 58.7 % SFP, clean filters including frequency converter 2.21 kW/(m/s) SFP, clean filters excluding frequency converter 2.10 kW/(m/s) Heating 32.00 kW - Air 8.3/15.5C - Water 70/50C - 0.8 kPa - 0.39 l/s Pipe connections 1 1/2" / 1 1/2" Cooling 36.72 kW - Air 26.0/18.6C - Water 6/12C - 28.0 kPa - 1.45 l/s Pipe connections 1 1/4" / 1 1/4" Eurovent energy efficiency class A Sound power level 63 125 250 500 1k 2k 4k 8k Hz Total Supply air 69 69 66 58 45 39 36 38 dB 61 dB(A) Outdoor air 63 73 72 63 59 51 44 33 dB 67 dB(A) Exhaust air 68 68 65 58 44 39 36 38 dB 60 dB(A) Extract air 63 74 73 66 63 59 51 43 dB 69 dB(A) Sound break out 62 71 60 50 51 48 42 37 dB 59 dB(A) Systemair Rt Telephone : +40 314055588 Telefax : +40 213514482 www.systemair.ro Systemair A/S - Air handling unit design SystemairCAD - Version C2013-12.04.D1 1/16/2014 Page 2 Project: ventilatii - cta Unit: Danvent DV80 Plan view Access side Systemair Rt Telephone : +40 314055588 Telefax : +40 213514482 www.systemair.ro Systemair A/S - Air handling unit design SystemairCAD - Version C2013-12.04.D1 1/16/2014 Page 3 Project: ventilatii - cta Unit: Danvent DV80 Right end Left end Doors and panels dimensions Systemair Rt Telephone : +40 314055588 Telefax : +40 213514482 www.systemair.ro Systemair A/S - Air handling unit design SystemairCAD - Version C2013-12.04.D1 1/16/2014 Page 4 Project: ventilatii - cta Unit: Danvent DV80 Technical specification The supply unit consist of Empty section Pressure drop 1 Pa Length 900 mm Damper Pressure drop 1 Pa Damper blades Standard Filter Dimensioning pressure drop 117 Pa Initial pressure drop/Final pressure drop 58/176 Pa Velocity, face area 1.74 m/s Velocity, filter area 0.09 m/s Filter class F7 Filter size 4x[490x592] +4x[490x490] Filter length 535 mm Empty section Pressure drop 1 Pa Length 450 mm Plate heat exchanger With face and by-pass damper Supply Extract Air flow 13280 13280 m3/h Pressure drop 77 77 Pa WINTER Air temperature before/after -12.0/5.6 18.0/4.2 C Air relative humidity before/after 80/21 50/97 % Condensate 0.4 l/min Capacity 78.85 kW Temperature efficiency 58.7 % Dry efficiency according to EN 308 at 13280 m3/h 53.3 % SUMMER Air temperature before/after 29.2/26.8 24.6/27.1 C Air relative humidity before/after 43/50 50/43 % Condensate 0.0 l/min Capacity 11.15 kW Temperature efficiency 53.3 % Heat exchanger type Aluminum heat exchanger Temperature efficiency Standard efficiency Drip tray Standard Mixing damper Supply Extract Systemair Rt Telephone : +40 314055588 Telefax : +40 213514482 www.systemair.ro Systemair A/S - Air handling unit design SystemairCAD - Version C2013-12.04.D1 1/16/2014 Page 5 Project: ventilatii - cta Unit: Danvent DV80 Air flow 1833 13280 m3/h Pressure drop 5 5 Pa WINTER Air temperature before/after 5.6/18.0 20.0/20.0 C Air relative humidity before/after 21.4/50.1 50.0/50.0 % Mixing ratio 86 % SUMMER Air temperature before/after 26.8/24.9 24.6/24.6 C Air relative humidity before/after 49.6/50.0 50.0/50.0 % Mixing ratio 86 % Damper blades 3 dampers Mixing damper type Standard Humidifier Air flow 13280 m3/h Pressure drop - Panel 42.0 Pa Pressure drop - Eliminator 29.0 Pa Total Pressure 71.0 Pa Evaporated water 1.7 g/kg Efficiency 90.3 % Max cooling temp decrease 4.1 C Air temperature before/after 14.0/9.9 C Air relative humidity before/after 55.0/94.7 % Total Pressure Service side Purge Connection 32 PVC Filling connection 3/8" BSP Width 2060 mm Height 1160 mm Depth 550 mm Net area 1.6 m2 Face velocity 2.3 m/s Pump - power 71.0 W Frame material Stainless steel Baffle material Hu-Cell Baffle thickness 150 mm Level detector 1 pcs Droplet eliminator 1 pcs Its necessary to connect the level detector before connection of water pump. If not the unit doesnt work properly and connection must be done by the installer. Heating coil, Fluid Air flow 13280 m3/h Pressure drop 18 Pa Air temperature before/after 8.3/15.5 C Air relative humidity before/after 50/31 % Capacity 32.00 kW Face velocity 1.72 m/s Fluid type Water Fluid temperature inlet/outlet 70.0/50.0 C Fluid flow rate 0.39 l/s Fluid pressure drop 0.8 kPa Fluid velocity 0.20 m/s Coil volume 16.5 l Connection side Service side Connection size inlet/outlet 1 1/2" / 1 1/2" Systemair Rt Telephone : +40 314055588 Telefax : +40 213514482 www.systemair.ro Systemair A/S - Air handling unit design SystemairCAD - Version C2013-12.04.D1 1/16/2014 Page 6 Project: ventilatii - cta Unit: Danvent DV80 Tube material Cu Fin material Al Fin spacing 2.1 mm No. of rows 2 Coil code DVH-80-W-Z-2-27-1125-1905-2.1-CU-Al-H-1 1/2 Cooling coil, Fluid Air flow 13280 m3/h Pressure drop air, wet coil with condensate droplets 29 Pa Air temperature before/after 26.0/18.6 C Air relative humidity before/after 52/80 % Total cooling capacity 36.72 kW Sensible cooling in % of total cooling 90 % Face velocity 1.72 m/s Condensate 0.1 l/min Fluid type Water Fluid temperature inlet/outlet 6.0/12.0 C Fluid flow rate 1.45 l/s Fluid pressure drop 28.0 kPa Fluid velocity 0.91 m/s Coil volume 21.8 l Connection side Service side Connection size inlet/outlet 1 1/4" / 1 1/4" Tube material Cu Fin material Al Fin spacing 2.1 mm No. of rows 3 Drip tray material Standard Coil code DVK-80-W-Z-3-22-1125-1905-2.1-CU-Al-H-1 1/4 Fan , Plug Air flow 13280 m3/h External pressure 382 Pa Pressure drop 25 Pa Static pressure 741 Pa Total pressure 783 Pa Absorbed power 3.75 kW Fan speed 1123 RPM Maximum fan speed 1230 RPM Efficiency by static pressure 72.9 % Efficiency by total pressure 77.0 % K-factor (p=1,2 kg/m3) 490 Fan type M-RH71C Operation frequency 58 Hz Max. operating frequency 64 Hz Direct drive Motor Motor type IE2 Motor types-size ABB-132MC Motor protection Thermistor Rated power 5.50 kW Speed (nominal) 965 RPM Current, Amp. 13.70 A Systemair Rt Telephone : +40 314055588 Telefax : +40 213514482 www.systemair.ro Systemair A/S - Air handling unit design SystemairCAD - Version C2013-12.04.D1 1/16/2014 Page 7 Project: ventilatii - cta Unit: Danvent DV80 Efficiency 86.1 % Efficiency, actual working point 86.0 % Voltage 3x400 V Consumed power from mains power supply, excluding frequency converter 4.36 kW Consumed power from mains power supply, including frequency converter 4.59 kW Sound attenuator Pressure drop 13 Pa 63 125 250 500 1k 2k 4k 8k Hz Sound attenuation 5 11 17 25 36 39 36 28 dB Cleaning of the material Standard The extract unit consist of Empty section Pressure drop 1 Pa Length 450 mm Inspection section Pressure drop 1 Pa Length 300 mm Empty section Pressure drop 1 Pa Length 150 mm Damper Pressure drop 1 Pa Damper blades Standard Filter Dimensioning pressure drop 117 Pa Initial pressure drop/Final pressure drop 58/176 Pa Velocity, face area 1.74 m/s Velocity, filter area 0.09 m/s Filter class F7 Filter size 4x[490x592] +4x[490x490] Filter length 535 mm Empty section Pressure drop 1 Pa Length 450 mm Empty section Pressure drop 1 Pa Length 900 mm Systemair Rt Telephone : +40 314055588 Telefax : +40 213514482 www.systemair.ro Systemair A/S - Air handling unit design SystemairCAD - Version C2013-12.04.D1 1/16/2014 Page 8 Project: ventilatii - cta Unit: Danvent DV80 Inspection section Pressure drop 1 Pa Length 600 mm Mixing damper Data are stated on supply. Plate heat exchanger Data are stated on supply. Fan , Plug Air flow 13280 m3/h External pressure 436 Pa Pressure drop 25 Pa Static pressure 683 Pa Total pressure 725 Pa Absorbed power 3.45 kW Fan speed 1091 RPM Maximum fan speed 1110 RPM Efficiency by static pressure 73.1 % Efficiency by total pressure 77.6 % K-factor (p=1,2 kg/m3) 490 Fan type M-RH71C Operation frequency 57 Hz Max. operating frequency 58 Hz Direct drive Motor Motor type IE2 Motor types-size ABB-132MA Motor protection Thermistor Rated power 4.00 kW Speed (nominal) 960 RPM Current, Amp. 10.00 A Efficiency 85.3 % Efficiency, actual working point 85.1 % Voltage 3x400 V Consumed power from mains power supply, excluding frequency converter 4.05 kW Consumed power from mains power supply, including frequency converter 4.27 kW Sound attenuator Pressure drop 13 Pa 63 125 250 500 1k 2k 4k 8k Hz Sound attenuation 5 11 17 25 36 39 36 28 dB Cleaning of the material Standard Systemair Rt Telephone : +40 314055588 Telefax : +40 213514482 www.systemair.ro Systemair A/S - Air handling unit design SystemairCAD - Version C2013-12.04.D1 1/16/2014 Page 9 Project: ventilatii - cta Unit: Danvent DV80 Other parts Sections Product Dimensions (width x height x length) Weight AHU1-5410 2270 x 2910 x 5410 mm 2458 kg AHU2-3990 2270 x 2910 x 3990 mm 2118 kg The unit sections are delivered mounted on base frame. Duct connections Product Dimensions (width x height) Outdoor 2100x1150 mm Supply 2100x1150 mm Extract 2100x1150 mm Exhaust 2100x1150 mm Systemair Rt Telephone : +40 314055588 Telefax : +40 213514482 www.systemair.ro