Shipboard Cable

Content
Cable Type
(Rate voltage)
High Voltage Power
Cable
(3.6/6kV,6/10kV)

Power & Lighting


Cable
(0.6/1kV)

Control & Signal


Cable
(150/250V)

Telephone and
Instrumentation
Cable

Unarmored
cables

Armored
cables

Armored & PVC


Protective covered cables

Page

---

SPYCB, FA-SPYCB

SPYCBY, FA-SPYCBY

---

TPYC, FA-TPYC

TPYCY, FA-TPYCY

---

SPYC,

FA-SPYC

12

---

---

SPYCY, FA-SPYCY

12

DPY, FA-DPY

DPYC, FA-DPYC

DPYCY, FA-DPYCY

13

TPY, FA-TPY

TPYC, FA-TPYC

TPYCY, FA-TPYCY

14

---

DPYCSLA,
FA-DPYCSLA

DPYCYSLA,
FA-DPYCYSLA

18

---

TPYCSLA,
FA-TPYCSLA

TPYCYSLA,
FA-TPYCYSLA

18

FR-DPY,
FR-FA-DPY

FR-DPYC,
FR-FA-DPYC

FR-DPYCY,
FR-FA-DPYCY

20

FR-TPY,
FR-FA-TPY

FR-TPYC,
FR-FA-TPYC

FR-TPYCY,
FR-FA-TPYCY

21

MPY, FA-MPY

MPYC, FA-MPYC

MPYCY, FA-MPYCY

26

---

MPYCSLA,
FA-MPYCSLA

MPYCYSLA,
FA-MPYCYSLA

28

---

MPYC-S, FA-MPYC-S

MPYCY-S, FA-MPYCY-S

28

FR-MPY,
FR-FA-MPY

FR-MPYC,
FR-FA-MPYC

FR-MPYCY,
FR-FA-MPYCY

32

TTY, FA-TTY

TTYC, FA-TTYC

TTYCY, FA-TTYCY

36

---

TTYCSLA,
FA-TTYCSLA

TTYCYSLA,
FA-TTYCYSLA

40

TTYC-SLA
FA-TTYC-SLA

TTYCY-SLA
FA-TTYCY-SLA

42

Electric Technical Information

43

CERTIFICATE

45

Symbols explanation for ships cables accordance to JIS C3410-2010


Symbols denoting number of cores and principal use
FA

Flame retardant(IEC 60332-3-22)

Four core for lighting and power

FR

Fire resistant(IEC 60331 1/2)

Multicore for control and signal

FR-FA Flame retardant and Fire resistant

TT Telephone and instrumentation

Single core for lighting and power

Portable or flexible

Double core for lighting and power

Three core for lighting and power

Symbols denoting constituents


Insulation (1)
P

Outer covering

EP

Armouring (2)

PVC

rubber
Y

Galvanized steel wire

Protective covering
Y

braid

PVC

PVC Protective

Others
-S

Individual core shield with braid

covering
SLA Common shield with Aluminium

CB Copper alloy wire


braid

foil-mylar tape and drain wire

-SLA Individual pair shield with


Aluminium foil-mylar tape and drain wire
E

Earth wire

Notes:
(1) For telephone cable, the insulation symbol is omitted.
(2) In the case of copper alloy wire braid, letter B shall be suffixed to letter C.

Symbols explanation example for cable type "0.6/1 kV FR-FA-TPYCY"


0.6/1 kV FR-FA-TPYCY
Construction of cable(Example)

 

Copper condutor
Mica tape
EPR insulation

Suitable filler

Suitable tape
PVC sheath
Galvanized steel wire braid
PVC protective covering

0.6/1 kVVoltage rate


FR-FAFlame retardant and Fire resistant
TThree core conductor
PEPR Insulation
YPVC sheath
CGalvanized steel wire braid
YPVC protective covering

1

High Voltage Power Cable

Power & Lighting Cable

Control & Signal Cable

Telephone and
Instrumentation Cable

High Voltage Power Cable

6/10 kV FA-TPYCY
 






Rated Voltage

3.6/6 kV

Power & Lighting Cable

6/10 kV
Power Cable
Cable Symbols

TPYC , FA-TPYC
TPYCY, FA-TPYCY
SPYCB , SPYCB
SPYCBY, PYCBY

Application Standard

Design guideJIS C 3410(2010),IEC 60092-350(2008-02),


IEC 60092-351(2004-04) IEC 60092-353(2001-04),
IEC 60092-354(2003-06), IEC 60092-359(1999-08)

Flame retardantIEC 60332-1& IEC 60332-3-22 Category A (FA-Type)


Max. conductor temperature90

Control & Signal Cable

CONSTRUCTION
Classification Code
Conductor

Construction Detail

S,T

Stranded tinned annealed copper wires as per JIS C 3410.

EPR as per JIS C 3410,IEC 60092-351

Cabling

Insulated conductors shall be cabled.


Flame retardant & Non-hygroscopic fillers may be used.
Suitable tape(s) may be applied on the cabled core.

Sheath

PVC as per JIS C 3410,IEC 60092-353

Armor

Braid of galvanized steel wires.


Coverage density is minimum 90%.

Insulation

CB
Paint

Telephone and
Instrumentation Cable

Protective Covering
Core identification

Braid of copper alloy wire, Coverage density is minimum 90 %.


(for single core only)

The white paint shall be painted uniformly on the steel wire braid
Protective covering Type, paint is dispensable.

PVC as per JIS C 3410.


Outer sheath color : Red

3Cores:White, Red, Blue

3

Diam. of
metal wire
braid
armour

Nominal
overall
diam.

Tolerance of
diam. over
sheath &
overall diam.

Cable
weight
(Approx.)
kg/km

Size

Construction

SQ

No./mm

mm

mm

mm

mm

mm

mm

10

7/1.35

4.05

2.5

1.3

0.3

17.6

0.7

560

16

7/1.70

5.10

2.5

1.4

0.3

18.8

0.8

660

25

7/2.14

6.42

2.5

1.4

0.3

20.1

0.8

795

35

7/2.52

7.56

2.5

1.5

0.3

21.5

0.9

940

50

19/1.78

8.90

2.5

1.5

0.3

22.8

0.9

1110

70

19/2.14

10.7

2.5

1.6

0.3

24.8

1.0

1380

95

19/2.52

12.6

2.5

1.7

0.3

26.9

1.1

1710

120

37/2.03

14.2

2.5

1.8

0.3

28.7

1.1

2010

150

37/2.25

15.8

2.5

1.8

0.3

30.3

1.2

2330

185

37/2.52

17.6

2.5

1.9

0.4

32.8

1.3

2890

240

61/2.25

20.3

2.6

2.0

0.4

35.9

1.4

3590

300

61/2.52

22.7

2.8

2.1

0.4

38.9

1.6

4330

TABLE 2 3.6/6 kV SPYCBY 3.6/6 kV FA-SPYCBY

O.D

Radial
Thickness
of
insulation

Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Radial
thickness
of
protective
covering

Conductor

Size

Construction

Nominal
overall
diam.

Tolerance
of diam.
over
sheath &
overall
diam.

Cable
weight
(Approx.)

kg/km

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

10

7/1.35

4.05

2.5

1.3

0.3

1.0

19.8

0.8

640

16

7/1.70

5.10

2.5

1.4

0.3

1.1

21.2

0.8

755

25

7/2.14

6.42

2.5

1.4

0.3

1.1

22.5

0.9

895

35

7/2.52

7.56

2.5

1.5

0.3

1.1

23.9

1.0

1050

50

19/1.78

8.90

2.5

1.5

0.3

1.2

25.4

1.0

1230

70

19/2.14

10.7

2.5

1.6

0.3

1.2

27.4

1.1

1520

95

19/2.52

12.6

2.5

1.7

0.3

1.3

29.7

1.2

1870

120

37/2.03

14.2

2.5

1.8

0.3

1.3

31.5

1.3

2180

150

37/2.25

15.8

2.5

1.8

0.3

1.4

33.3

1.3

2520

185

37/2.52

17.6

2.5

1.9

0.4

1.4

35.8

1.4

3090

240

61/2.25

20.3

2.6

2.0

0.4

1.5

39.3

1.6

3830

300

61/2.52

22.7

2.8

2.1

0.4

1.6

42.5

1.6

4610

4

High Voltage Power Cable

Radial
thickness
of
sheath

Power & Lighting Cable

O.D

Radial
thickness
of
insulation

Control & Signal Cable

Conductor

Telephone and
Instrumentation Cable

TABLE 1 3.6/6 kV SPYCB 3.6/6 kV FA-SPYCB

High Voltage Power Cable

TABLE 3 6/10 kV SPYCB 6/10 kV FA-SPYCB


Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Nominal
overall
diam.

Tolerance
of diam.
over sheath &
overall diam.

Power & Lighting Cable

Size Construction

O.D

Radial
thickness
of
insulation

SQ

No./mm

mm

mm

mm

mm

mm

mm

16

7/1.70

5.10

3.4

1.5

0.3

20.8

0.8

765

25

7/2.14

6.42

3.4

1.5

0.3

22.1

0.9

910

35

7/2.52

7.56

3.4

1.6

0.3

23.5

0.9

1060

50

19/1.78

8.90

3.4

1.6

0.3

24.8

1.0

1230

70

19/2.14

10.7

3.4

1.7

0.3

26.8

1.1

1510

95

19/2.52

12.6

3.4

1.8

0.3

28.9

1.2

1850

120

37/2.03

14.2

3.4

1.8

0.3

30.5

1.2

2150

150

37/2.25

15.8

3.4

1.9

0.4

32.8

1.3

2610

185

37/2.52

17.6

3.4

2.0

0.4

34.8

1.4

3060

240

61/2.25

20.3

3.4

2.1

0.4

37.7

1.5

3760

300

61/2.52

22.7

3.4

2.2

0.4

40.3

1.6

4470

Conductor

Cable
weight
(Approx.)
kg/km

TABLE 4 6/10 kV SPYCBY 6/10 kV FA-SPYCBY


Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Radial
thickness of
protective
covering

Nominal
overall
diam.

Tolerance
of diam.
over sheath &
overall diam.

Control & Signal Cable

Size Construction

O.D

Radial
thickness
of
insulation

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

16

7/1.70

5.10

3.4

1.5

0.3

1.1

23.2

0.9

870

25

7/2.14

6.42

3.4

1.5

0.3

1.2

24.7

1.0

1030

35

7/2.52

7.56

3.4

1.6

0.3

1.2

26.1

1.0

1190

50

19/1.78

8.90

3.4

1.6

0.3

1.2

27.4

1.1

1360

70

19/2.14

10.7

3.4

1.7

0.3

1.3

29.6

1.2

1670

95

19/2.52

12.6

3.4

1.8

0.3

1.3

31.7

1.3

2020

120

37/2.03

14.2

3.4

1.8

0.3

1.4

33.5

1.3

2340

150

37/2.25

15.8

3.4

1.9

0.4

1.4

35.8

1.4

2820

185

37/2.52

17.6

3.4

2.0

0.4

1.5

38.2

1.5

3290

240

61/2.25

20.3

3.4

2.1

0.4

1.5

41.1

1.6

4010

300

61/2.52

22.7

3.4

2.2

0.4

1.6

43.9

1.7

4760

Conductor

Telephone and
Instrumentation Cable

5

Cable
weight
(Approx.)
kg/km

Tolerance
of diam.
over sheath &
overall diam.

Size Construction

O.D

SQ

No./mm

mm

mm

mm

mm

mm

mm

kg/km

10

7/1.35

4.05

2.5

1.9

0.4

34.1

1.4

1620

16

7/1.70

5.10

2.5

2.0

0.4

36.5

1.5

1920

25

7/2.14

6.42

2.5

2.1

0.4

39.6

1.6

2370

35

7/2.52

7.56

2.5

2.2

0.4

42.2

1.6

2800

50

19/1.78

8.90

2.5

2.4

0.4

45.5

1.7

3360

70

19/2.14

10.7

2.5

2.5

0.4

49.6

1.8

4210

95

19/2.52

12.6

2.5

2.7

0.4

54.1

1.9

5260

120

37/2.03

14.2

2.5

2.8

0.4

57.8

2.0

6210

150

37/2.25

15.8

2.5

2.9

0.4

61.6

2.1

7250

Cable
weight
(Approx.)

TABLE 6 3.6/6 kV TPYCY 3.6/6 kV FA-TPYCY


Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Radial
thickness
of protective
covering

Nominal
overall
diam.

Tolerance
of
overall
diam.

Size Construction

O.D

Radial
thickness
of
insulation

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

kg/km

10

7/1.35

4.05

2.5

1.9

0.4

1.5

37.5

1.5

1850

16

7/1.70

5.10

2.5

2.0

0.4

1.5

39.9

1.6

2170

25

7/2.14

6.42

2.5

2.1

0.4

1.6

43.2

1.7

2650

35

7/2.52

7.56

2.5

2.2

0.4

1.7

46.0

1.7

3120

50

19/1.78

8.90

2.5

2.4

0.4

1.7

49.3

1.8

3710

70

19/2.14

10.7

2.5

2.5

0.4

1.8

53.6

1.9

4610

95

19/2.52

12.6

2.5

2.7

0.4

2.0

58.5

2.0

5740

120

37/2.03

14.2

2.5

2.8

0.4

2.0

62.2

2.1

6720

150

37/2.25

15.8

2.5

2.9

0.4

2.1

66.2

2.2

7820

Conductor

6

Cable
weight
(Approx.)

High Voltage Power Cable

Nominal
overall
diam.

Power & Lighting Cable

Diam. of
metal
wire braid
armour

Control & Signal Cable

Radial
thickness
of
sheath

Radial
thickness
of
insulation

Conductor

Telephone and
Instrumentation Cable

TABLE 5 3.6/6 kV TPYC 3.6/6 kV FA-TPYC

High Voltage Power Cable

TABLE 7 6/10 kV TPYC 6/10 kV FA-TPYC


Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Nominal
overall
diam.

Tolerance
of diam.
over sheath &
overall diam.

Power & Lighting Cable

Size Construction

O.D

Radial
thickness
of
insulation

SQ

No./mm

mm

mm

mm

mm

mm

mm

kg/km

16

7/1.70

5.10

3.4

2.2

0.4

41.0

1.6

2290

25

7/2.14

6.42

3.4

2.3

0.4

44.1

1.7

2760

35

7/2.52

7.56

3.4

2.4

0.4

46.7

1.7

3220

50

19/1.78

8.90

3.4

2.5

0.4

49.8

1.8

3780

70

19/2.14

10.7

3.4

2.7

0.4

54.1

1.9

4690

95

19/2.52

12.6

3.4

2.8

0.4

58.4

2.0

5740

120

37/2.03

14.2

3.4

3.0

0.4

62.3

2.1

6750

150

37/2.25

15.8

3.4

3.1

0.4

65.9

2.2

7790

Conductor

Cable
weight
(Approx.)

TABLE 8 6/10 kV TPYCY 6/10 kV FA-TPYCY


Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Radial
thickness
of protective
covering

Nominal
overall
diam.

Tolerance
of
overall
diam.

Cable
weight
(Approx.)

Control & Signal Cable

Size Construction

O.D

Radial
thickness
of
insulation

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

kg/km

16

7/1.70

5.10

3.4

2.2

0.4

1.6

44.6

1.7

2590

25

7/2.14

6.42

3.4

2.3

0.4

1.7

47.9

1.8

3100

35

7/2.52

7.56

3.4

2.4

0.4

1.8

50.7

1.8

3590

50

19/1.78

8.90

3.4

2.5

0.4

1.8

53.8

1.9

4180

70

19/2.14

10.7

3.4

2.7

0.4

2.0

58.5

2.0

5170

95

19/2.52

12.6

3.4

2.8

0.4

2.1

63.0

2.1

6290

120

37/2.03

14.2

3.4

3.0

0.4

2.2

67.1

2.2

7360

150

37/2.25

15.8

3.4

3.1

0.4

2.2

70.7

2.3

8440

Conductor

Telephone and
Instrumentation Cable

7

Telephone and
Instrumentation Cable

8

Control & Signal Cable

Power & Lighting Cable

High Voltage Power Cable

High Voltage Power Cable

Power & Lighting Cable

Control & Signal Cable

Telephone and
Instrumentation Cable

9

High Voltage Power Cable

0.6/1kV FA-TPYCY
 



Rated Voltage

0.6/1 kV

Power & Lighting Cable

Power and Lighting Cable


Cable Symbols

SPYC, FA-SPYC
SPYCY , FA-SPYCY
DPY, FA-DPY
DPYC, FA-DPYC
DPYCY, FA-DPYCY
TPY, FA-TPY

Application Standard

Design guideJIS C 3410(2010),IEC 60092-350(2008-02),


IEC 60092-351(2004-04),IEC 60092-353(2001-04),
IEC 60092-359(1999-08)
Flame retardantIEC 60332-1& IEC 60332-3-22 Category A (FA-Type)

Control & Signal Cable

Max. conductor temperature90

CONSTRUCTION
Classification Code
Conductor
Insulation
Cabling

Construction Detail

S,D,T

Stranded tinned annealed copper wires as per JIS C 3410.

EPR as per JIS C 3410,IEC 60092-351

Insulated conductors shall be cabled.

Flame retardant & Non-hygroscopic fillers may be used.

Suitable tape(s) may be applied on the cabled core.

Sheath

PVC as per JIS C 3410,IEC 60092-353

Armor

Braid of galvanized steel wires.

Telephone and
Instrumentation Cable

Paint

Protective Covering


Core identification

Coverage density is minimum 90%.


The white paint shall be painted uniformly on the steel wire braid
Protective covering Type, paint is dispensable.
PVC as per JIS C 3410.
Outer sheath color : Black
2Cores:Black, White
3Cores:Black, White, Red
11

SQ

No./mm

mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

1.0

1.0

5.9

0.3

7.2

0.4

100

2.5

7/0.67

2.01

1.0

1.0

6.3

0.3

7.6

0.4

120

7/0.85

2.55

1.0

1.0

6.9

0.3

8.2

0.4

140

7/1.04

3.12

1.0

1.0

7.4

0.3

8.7

0.4

170

10

7/1.35

4.05

1.0

1.1

8.6

0.3

9.9

0.4

225

16

7/1.70

5.10

1.0

1.1

9.6

0.3

10.9

0.4

300

25

7/2.14

6.42

1.2

1.2

11.5

0.3

12.8

0.5

425

35

7/2.52

7.56

1.2

1.2

12.7

0.3

14.0

0.6

535

50

19/1.78

8.90

1.4

1.3

14.6

0.3

15.9

0.6

700

70

19/2.14

10.7

1.4

1.4

16.6

0.3

17.9

0.7

940

95

19/2.52

12.6

1.6

1.5

19.3

0.3

20.6

0.8

1260

120

37/2.03

14.2

1.6

1.5

20.9

0.3

22.2

0.9

1520

150

37/2.25

15.8

1.8

1.6

23.1

0.3

24.4

1.0

1840

185

37/2.52

17.6

2.0

1.7

25.5

0.3

26.8

1.1

2260

240

61/2.25

20.3

2.2

1.8

28.8

0.3

30.1

1.2

2920

300

61/2.52

22.7

2.4

1.9

31.8

0.4

33.6

1.3

3700

O.D

Nominal
diam.
over
sheath

Nominal
overall
diam.

Tolerance
of diam. over
sheath &
overall diam.

Cable
weight
(Approx.)
kg/km

TABLE 10 0.6/1 kV SPYCY 0.6/1 kV FA-SPYCY

O.D

Radial
thickness
of
insulation

Radial
thickness
of
sheath

Nominal
diam.
over
sheath

Diam.
of
metal
wire for
braid

Redial
thickness
of
protective
covering

Nominal
overall
diam.

Tolerance
of
overall
diam.

Conductor
Size

Construction

Cable
weight
(Approx.)

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

1.0

1.0

5.9

0.3

0.8

9.0

0.4

135

2.5

7/0.67

2.01

1.0

1.0

6.3

0.3

0.8

9.4

0.4

150

7/0.85

2.55

1.0

1.0

6.9

0.3

0.8

10.0

0.4

175

7/1.04

3.12

1.0

1.0

7.4

0.3

0.8

10.5

0.4

205

10

7/1.35

4.05

1.0

1.1

8.6

0.3

0.8

11.7

0.5

270

16

7/1.70

5.10

1.0

1.1

9.6

0.3

0.9

12.9

0.5

350

25

7/2.14

6.42

1.2

1.2

11.5

0.3

0.9

14.8

0.6

485

35

7/2.52

7.56

1.2

1.2

12.7

0.3

1.0

16.2

0.6

610

50

19/1.78

8.90

1.4

1.3

14.6

0.3

1.0

18.1

0.7

780

70

19/2.14

10.7

1.4

1.4

16.6

0.3

1.0

20.1

0.8

1030

95

19/2.52

12.6

1.6

1.5

19.3

0.3

1.1

23.0

0.9

1370

120

37/2.03

14.2

1.6

1.5

20.9

0.3

1.2

24.8

1.0

1650

150

37/2.25

15.8

1.8

1.6

23.1

0.3

1.2

27.0

1.1

1980

185

37/2.52

17.6

2.0

1.7

25.5

0.3

1.3

29.6

1.2

2430

240

61/2.25

20.3

2.2

1.8

28.8

0.3

1.4

33.1

1.3

3130

300

61/2.52

22.7

2.4

1.9

31.8

0.4

1.4

36.6

1.5

3930

12

kg/km

High Voltage Power Cable

Construction

Radial
thickness
of
sheath

Power & Lighting Cable

Size

Diam.
of
metal
wire for
braid
mm

Radial
thickness
of
insulation

Conductor

Control & Signal Cable

FA-SPYC

Telephone and
Instrumentation Cable

TABLE 9 0.6/1 kV SPYC 0.6/1 kV

High Voltage Power Cable

TABLE 11 0.6/1 kV DPY 0.6/1 kV FA-DPY


Radial
thickness
of
sheath

Nominal
diam.
over
sheath

Tolerance
of
overall
diam.

Cable
weight
(Approx.)
kg/km

Power & Lighting Cable

Size Construction

O.D

Radial
thickness
of
insulation

SQ

No./mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

1.0

1.1

10.4

0.5

120

2.5

7/0.67

2.01

1.0

1.2

11.5

0.5

155

7/0.85

2.55

1.0

1.2

12.6

0.6

200

7/1.04

3.12

1.0

1.3

13.9

0.6

255

10

7/1.35

4.05

1.0

1.3

15.8

0.7

360

16

7/1.70

5.10

1.0

1.4

18.1

0.8

515

25

7/2.14

6.42

1.2

1.5

21.7

0.9

770

35

7/2.52

7.56

1.2

1.6

24.2

1.0

1010

50

19/1.78

8.90

1.4

1.8

28.1

1.2

1360

70

19/2.14

10.7

1.4

1.9

31.9

1.3

1860

95

19/2.52

12.6

1.6

2.1

37.3

1.6

2550

120

37/2.03

14.2

1.6

2.3

40.9

1.6

3150

150

37/2.25

15.8

1.8

2.4

45.1

1.7

3840

185

37/2.52

17.6

2.0

2.6

49.9

1.9

4780

Conductor

TABLE 12 0.6/1 kV DPYC 0.6/1 kV FA-DPYC

Control & Signal Cable

Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Nominal
overall
diam.

Tolerance
of diam.
over sheath &
overall diam.

Size Construction

O.D

Radial
thickness
of
insulation

SQ

No./mm

mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

1.0

1.1

0.3

11.7

0.5

205

2.5

7/0.67

2.01

1.0

1.2

0.3

12.8

0.5

250

7/0.85

2.55

1.0

1.2

0.3

13.9

0.6

300

7/1.04

3.12

1.0

1.3

0.3

15.2

0.6

370

10

7/1.35

4.05

1.0

1.3

0.3

17.1

0.7

490

16

7/1.70

5.10

1.0

1.4

0.3

19.4

0.8

600

25

7/2.14

6.42

1.2

1.5

0.3

23.0

0.9

945

35

7/2.52

7.56

1.2

1.6

0.3

25.5

1.0

1200

50

19/1.78

8.90

1.4

1.8

0.3

29.4

1.2

1580

70

19/2.14

10.7

1.4

1.9

0.4

33.7

1.3

2210

95

19/2.52

12.6

1.6

2.1

0.4

39.1

1.6

2960

120

37/2.03

14.2

1.6

2.3

0.4

42.7

1.6

3600

150

37/2.25

15.8

1.8

2.4

0.4

46.9

1.7

4340

185

37/2.52

17.6

2.0

2.6

0.4

51.7

1.9

5320

Conductor

Telephone and
Instrumentation Cable

13

Cable
weight
(Approx.)
kg/km

Nominal
overall
diam.

Tolerance
of
overall
diam.

Size Construction

O.D

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

1.0

1.1

0.3

0.9

13.7

0.5

260

2.5

7/0.67

2.01

1.0

1.2

0.3

0.9

14.8

0.6

305

7/0.85

2.55

1.0

1.2

0.3

0.9

15.9

0.6

365

7/1.04

3.12

1.0

1.3

0.3

1.0

17.4

0.7

445

10

7/1.35

4.05

1.0

1.3

0.3

1.0

19.3

0.8

575

16

7/1.70

5.10

1.0

1.4

0.3

1.1

21.8

0.9

765

25

7/2.14

6.42

1.2

1.5

0.3

1.2

25.6

1.0

1080

35

7/2.52

7.56

1.2

1.6

0.3

1.2

28.1

1.1

1350

50

19/1.78

8.90

1.4

1.8

0.3

1.3

32.2

1.3

1770

70

19/2.14

10.7

1.4

1.9

0.4

1.4

36.7

1.5

2440

95

19/2.52

12.6

1.6

2.1

0.4

1.6

42.7

1.6

3280

120

37/2.03

14.2

1.6

2.3

0.4

1.7

46.5

1.7

3970

150

37/2.25

15.8

1.8

2.4

0.4

1.8

50.9

1.8

4760

185

37/2.52

17.6

2.0

2.6

0.4

1.9

55.9

1.9

5810

Cable
weight
(Approx.)
kg/km

TABLE 14 0.6/1 kV TPY 0.6/1 kV FA-TPY


Radial
thickness
of
sheath

Nominal
diam.
over
sheath

Tolerance
of
overall
diam.

Cable
weight
(Approx.)
kg/km

Size Construction

O.D

Radial
thickness
of
insulation

SQ

No./mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

1.0

1.2

11.2

0.5

150

2.5

7/0.67

2.01

1.0

1.2

12.2

0.5

195

7/0.85

2.55

1.0

1.2

13.4

0.6

255

7/1.04

3.12

1.0

1.3

14.8

0.6

335

10

7/1.35

4.05

1.0

1.4

17.0

0.7

485

16

7/1.70

5.10

1.0

1.5

19.5

0.8

700

25

7/2.14

6.42

1.2

1.6

23.4

1.0

1060

35

7/2.52

7.56

1.2

1.7

26.1

1.1

1390

50

19/1.78

8.90

1.4

1.9

30.2

1.3

1870

70

19/2.14

10.7

1.4

2.0

34.3

1.4

2570

95

19/2.52

12.6

1.6

2.2

40.1

1.6

3530

120

37/2.03

14.2

1.6

2.4

44.0

1.7

4370

150

37/2.25

15.8

1.8

2.5

48.5

1.8

5340

185

37/2.52

17.6

2.0

2.7

53.6

1.9

6640

Conductor

14

High Voltage Power Cable

Radial
thickness of
protective
covering

Power & Lighting Cable

Diam. of
metal
wire braid
armour

Control & Signal Cable

Radial
thickness
of
sheath

Radial
thickness
of
insulation

Conductor

Telephone and
Instrumentation Cable

TABLE 13 0.6/1 kV DPYCY 0.6/1 kV FA-DPYCY

High Voltage Power Cable

TABLE 15 0.6/1 kV TPYC 0.6/1 kV FA-TPYC


Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Nominal
overall
diam.

Tolerance
of diam.
over sheath &
overall diam.

Power & Lighting Cable

Size Construction

O.D

Radial
thickness
of
insulation

SQ

No./mm

mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

1.0

1.2

0.3

12.5

0.5

245

2.5

7/0.67

2.01

1.0

1.2

0.3

13.5

0.5

295

7/0.85

2.55

1.0

1.2

0.3

14.7

0.6

365

7/1.04

3.12

1.0

1.3

0.3

16.1

0.6

455

10

7/1.35

4.05

1.0

1.4

0.3

18.3

0.7

625

16

7/1.70

5.10

1.0

1.5

0.3

20.8

0.8

855

25

7/2.14

6.42

1.2

1.6

0.3

24.7

1.0

1240

35

7/2.52

7.56

1.2

1.7

0.3

27.4

1.1

1600

50

19/1.78

8.90

1.4

1.9

0.4

32.0

1.3

2200

70

19/2.14

10.7

1.4

2.0

0.4

36.1

1.4

2950

95

19/2.52

12.6

1.6

2.2

0.4

41.9

1.6

3980

120

37/2.03

14.2

1.6

2.4

0.4

45.8

1.7

4860

150

37/2.25

15.8

1.8

2.5

0.4

50.3

1.8

5870

185

37/2.52

17.6

2.0

2.7

0.4

55.4

1.9

7230

Conductor

Cable
weight
(Approx.)
kg/km

TABLE 16 0.6/1 kV TPYCY 0.6/1 kV FA-TPYCY

Control & Signal Cable

Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Radial
thickness of
protective
covering

Nominal
overall
diam.

Tolerance
of
overall
diam.

Size Construction

O.D

Radial
thickness
of
insulation

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

1.0

1.2

0.3

0.9

14.5

0.6

300

2.5

7/0.67

2.01

1.0

1.2

0.3

0.9

15.5

0.6

355

7/0.85

2.55

1.0

1.2

0.3

1.0

16.9

0.7

440

7/1.04

3.12

1.0

1.3

0.3

1.0

18.3

0.7

535

10

7/1.35

4.05

1.0

1.4

0.3

1.1

20.7

0.8

725

16

7/1.70

5.10

1.0

1.5

0.3

1.1

23.2

0.9

970

25

7/2.14

6.42

1.2

1.6

0.3

1.2

27.3

1.1

1390

35

7/2.52

7.56

1.2

1.7

0.3

1.3

30.2

1.2

1770

50

19/1.78

8.90

1.4

1.9

0.4

1.4

35.0

1.4

2420

70

19/2.14

10.7

1.4

2.0

0.4

1.5

39.5

1.6

3220

Conductor

Cable
weight
(Approx.)
kg/km

Telephone and
Instrumentation Cable

95

19/2.52

12.6

1.6

2.2

0.4

1.6

45.5

1.7

4310

120

37/2.03

14.2

1.6

2.4

0.4

1.7

49.6

1.8

5250

150

37/2.25

15.8

1.8

2.5

0.4

1.9

54.5

1.9

6350

185

37/2.52

17.6

2.0

2.7

0.4

2.0

59.8

2.0

7770

15

Telephone and
Instrumentation Cable

16

Control & Signal Cable

Power & Lighting Cable

High Voltage Power Cable

High Voltage Power Cable

0.6/1kV FA-TPYCYSLA
  



Rated Voltage

0.6/1 kV

Power & Lighting Cable

Power and Lighting Cable


Cable Symbols

DPYCSLA, FA-DPYCSLA
TPYCSLA, FA-TPYCSLA
DPYCYSLA, FA-DPYCYSLA
TPYCYSLA, FA-TPYCYSLA

Application Standard

Design guideJIS C 3410(2010),IEC 60092-350(2008-02),


IEC 60092-351(2004-04), IEC 60092-353(2001-04),
IEC 60092-359(1999-08)
Flame retardantIEC 60332-1& IEC 60332-3-22 Category A (FA-Type)
Max. conductor temperature90

CONSTRUCTION

Control & Signal Cable

Classification Code
Conductor
Insulation
Cabling

Construction Detail

D(T)

Stranded tinned annealed copper wires as per JIS C 3410.

EPR as per JIS C 3410,IEC 60092-351

Insulated conductors shall be cabled.

Flame retardant & Non-hygroscopic fillers may be used.

Suitable tape(s) may be applied on the cabled core.

SLA

Overall Shielded with Aluminium foil-mylar tape and drain wire

Sheath

PVC as per JIS C 3410,IEC 60092-353

Armor

Braid of galvanized steel wires.

Shielded


Paint

Telephone and
Instrumentation Cable

Protective Covering


Core identification

Coverage density is minimum 90%.


The white paint shall be painted uniformly on the steel wire braid
Protective covering Type, paint is dispensable.
PVC as per JIS C 3410.
Outer sheath color : Black
2Cores:Black, White
3Cores:Black, White, Red

17

Radial
thickness
of
sheath

Diam. of
metal wire
braid
armour

Nominal
overall
diam.

Tolerance of
diam. over
sheath &
overall diam.

Cable
weight
(Approx.)

Size

Construction

O.D

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

kg/km

1.5

7/0.52

1.56

1.0

0.05

1.1

0.3

11.9

0.5

215

2.5

7/0.67

2.01

1.0

0.05

1.2

0.3

13.0

0.5

260

7/0.85

2.55

1.0

0.05

1.2

0.3

14.1

0.6

310

Nominal
overall
diam.

Tolerance of
diam. over
sheath &
overall diam.

Cable
weight
(Approx.)

Size
No.

SQ

Construction

O.D

Radial
thickness
of
insulation

AL-mylar
tape
thickness

Radial
thickness
of
sheath

Diam. of
metal wire
braid
armour

No./mm

mm

mm

mm

mm

mm

mm

mm

kg/km

1.5

7/0.52

1.56

1.0

0.05

1.2

0.3

12.7

0.5

255

2.5

7/0.67

2.01

1.0

0.05

1.2

0.3

13.7

0.5

305

7/0.85

2.55

1.0

0.05

1.2

0.3

14.9

0.6

375

TABLE 19 0.6/1 kV DPYCYSLA 0.6/1 kV FA-DPYCYSLA


AL-mylar
tape
thickness

Radial
thickness
of
sheath

Diam. of
metal wire
braid
armour

Radial
Tolerance
Cable
thickness Nominal
of
weight
overall
of
overall
(Approx.)
diam.
protective
diam.
covering

Size

Construction

O.D

Radial
thickness
of
insulation

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

kg/km

1.5

7/0.52

1.56

1.0

0.05

1.1

0.3

0.9

13.9

0.6

270

2.5

7/0.67

2.01

1.0

0.05

1.2

0.3

0.9

15.0

0.6

320

7/0.85

2.55

1.0

0.05

1.2

0.3

1.0

16.3

0.7

385

No. of
cores

Conductor

TABLE 20 0.6/1 kV TPYCYSLA 0.6/1 kV FA-TPYCYSLA


AL-mylar
tape
thickness

Radial
thickness
of
sheath

Diam. of
metal wire
braid
armour

Radial
Tolerance
Cable
thickness Nominal
of
weight
overall
of
overall
(Approx.)
diam.
protective
diam.
covering

Size

Construction

O.D

Radial
thickness
of
insulation

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

kg/km

1.5

7/0.52

1.56

1.0

0.05

1.2

0.3

0.9

14.7

0.6

315

2.5

7/0.67

2.01

1.0

0.05

1.2

0.3

0.9

15.7

0.6

365

7/0.85

2.55

1.0

0.05

1.2

0.3

1.0

17.1

0.7

450

No. of
cores

Conductor

18

Power & Lighting Cable

Conductor

No. of
cores

0.6/1 kV FA-TPYCSLA

Control & Signal Cable

TABLE 18 0.6/1 kV TPYCSLA

Telephone and
Instrumentation Cable

No.

AL-mylar
tape
thickness

Radial
thickness
of
insulation

Conductor

No. of
cores

High Voltage Power Cable

TABLE 17 0.6/1 kV DPYCSLA 0.6/1 kV FA-DPYCSLA

High Voltage Power Cable

0.6/1kV FR-FA-TPYCY
 



Rated Voltage

0.6/1 kV

Power & Lighting Cable

Power and Lighting Cable


Cable Symbols

FR-DPY, FR-FA-DPY
FR-DPYC, FR-FA-DPYC
FR-DPYCY, FR-FA-DPYCY
FR-TPY, FR-FA-TPY
FR-TPYC, FR-FA-TPYC
FR-TPYCY, FR-FA-TPYCY

Application Standard

Design guideJIS C 3410(2010),IEC 60092-350(2008-02),


IEC 60092-351(2004-04), IEC 60092-353(2001-04),
IEC 60092-359(1999-08)
Flame retardantIEC 60332-1& IEC 60332-3-22 Category A (FA-Type)

Control & Signal Cable

Fire resistantIEC 60331 1/2


Max. conductor temperature90

CONSTRUCTION
Classification Code
Conductor
Insulation
Cabling

Construction Detail

D(T)

Stranded tinned annealed copper wires as per JIS C 3410.

EPR as per JIS C 3410,IEC 60092-351

Insulated conductors shall be cabled.

Flame retardant & Non-hygroscopic fillers may be used.

Suitable tape(s) may be applied on the cabled core.

Sheath

PVC as per JIS C 3410,IEC 60092-353

Armor

Braid of galvanized steel wires.

Telephone and
Instrumentation Cable

Paint

Protective Covering


Core identification

Coverage density is minimum 90%.


The white paint shall be painted uniformly on the steel wire braid
Protective covering Type, paint is dispensable.
PVC as per JIS C 3410.
Outer sheath color : Gray
2CoresBlack, White
3CoresBlack, White, Red
19

Conductor

Fire
resistant
layer

Radial
thickness
of
insulation

Radial
thickness
of
sheath

Nominal
overall
diam.

Tolerance
of
overall
diam.

Cable
weight
(Approx.)

Size

Construction

O.D

SQ

No./mm

mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

0.5

1.0

1.2

12.8

0.6

165

2.5

7/0.67

2.01

0.5

1.0

1.3

13.9

0.6

205

7/0.85

2.55

0.5

1.0

1.3

15.0

0.7

255

7/1.04

3.12

0.5

1.0

1.3

16.1

0.7

310

10

7/1.35

4.05

0.5

1.0

1.4

18.2

0.8

430

16

7/1.70

5.10

0.5

1.0

1.5

20.5

0.9

590

25

7/2.14

6.42

0.5

1.2

1.6

24.1

1.0

860

35

7/2.52

7.56

0.5

1.2

1.7

26.6

1.1

1110

50

19/1.78

8.90

0.5

1.4

1.9

30.5

1.3

1480

70

19/2.14

10.7

0.5

1.4

2.0

34.3

1.4

1990

95

19/2.52

12.6

0.5

1.6

2.2

39.7

1.6

2700

120

37/2.03

14.2

0.5

1.6

2.3

43.1

1.7

3300

150

37/2.25

15.8

0.5

1.8

2.5

47.5

1.8

4030

185

37/2.52

17.6

0.5

2.0

2.7

52.3

1.9

4980

kg/km

High Voltage Power Cable

TABLE 21 0.6/1 kV FR-DPY 0.6/1 kV FR-FA-DPY

Power & Lighting Cable

Fire
resistant
layer

Radial
thickness
of
insulation

Radial
thickness
of
sheath

Diam. of
metal wire
braid
armour

Nominal
overall
diam.

Tolerance
of
overall
diam.

Cable
weight
(Approx.)

Size

Construction

O.D

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

0.5

1.0

1.2

0.3

14.1

0.6

270

2.5

7/0.67

2.01

0.5

1.0

1.3

0.3

15.2

0.6

320

7/0.85

2.55

0.5

1.0

1.3

0.3

16.3

0.7

375

7/1.04

3.12

0.5

1.0

1.3

0.3

17.4

0.7

440

10

7/1.35

4.05

0.5

1.0

1.4

0.3

19.5

0.8

575

16

7/1.70

5.10

0.5

1.0

1.5

0.3

21.8

0.9

755

25

7/2.14

6.42

0.5

1.2

1.6

0.3

25.4

1.0

1060

35

7/2.52

7.56

0.5

1.2

1.7

0.3

27.9

1.1

1320

50

19/1.78

8.90

0.5

1.4

1.9

0.4

32.3

1.3

1820

70

19/2.14

10.7

0.5

1.4

2.0

0.4

36.1

1.4

2370

95

19/2.52

12.6

0.5

1.6

2.2

0.4

41.5

1.6

3140

120

37/2.03

14.2

0.5

1.6

2.3

0.4

44.9

1.7

3770

150

37/2.25

15.8

0.5

1.8

2.5

0.4

49.3

1.8

4550

185

37/2.52

17.6

0.5

2.0

2.7

0.4

54.1

1.9

5550

20

kg/km

Telephone and
Instrumentation Cable

Conductor

Control & Signal Cable

TABLE 22 0.6/1 kV FR-DPYC 0.6/1 kV FR-FA-DPYC

High Voltage Power Cable


TABLE 23 0.6/1 kV FR-DPYCY 0.6/1 kV FR-FA-DPYCY
Conductor
Size Construction O.D

Fire
resistant
layer

Radial
thickness
of
insulation

Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Radial
thickness of
protective
covering

Nominal
overall
diam.

Tolerance
of
overall
diam.

Cable
weight
(Approx.)
kg/km

Power & Lighting Cable

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

0.5

1.0

1.2

0.3

1.0

16.3

0.7

340

2.5

7/0.67

2.01

0.5

1.0

1.3

0.3

1.0

17.4

0.7

395

7/0.85

2.55

0.5

1.0

1.3

0.3

1.0

18.5

0.7

455

7/1.04

3.12

0.5

1.0

1.3

0.3

1.0

19.6

0.8

530

10

7/1.35

4.05

0.5

1.0

1.4

0.3

1.1

21.9

0.9

685

16

7/1.70

5.10

0.5

1.0

1.5

0.3

1.1

24.4

1.0

875

25

7/2.14

6.42

0.5

1.2

1.6

0.3

1.2

28.0

1.1

1210

35

7/2.52

7.56

0.5

1.2

1.7

0.3

1.3

30.7

1.2

1500

50

19/1.78

8.90

0.5

1.4

1.9

0.4

1.4

35.3

1.4

2030

70

19/2.14

10.7

0.5

1.4

2.0

0.4

1.5

39.5

1.6

2640

95

19/2.52

12.6

0.5

1.6

2.2

0.4

1.6

45.1

1.7

3480

120

37/2.03

14.2

0.5

1.6

2.3

0.4

1.7

48.7

1.8

4160

150

37/2.25

15.8

0.5

1.8

2.5

0.4

1.8

53.3

1.9

4990

185

37/2.52

17.6

0.5

2.0

2.7

0.4

2.0

58.5

2.0

6080


TABLE 24 0.6/1 kV FR-TPY 0.6/1 kV FR-FA-TPY

Control & Signal Cable

Conductor

Fire
resistant
layer

Radial
thickness
of
insulation

Radial
thickness
of
sheath

Nominal
overall
diam.

Tolerance
of
overall
diam.

Size Construction

O.D

SQ

mm

mm

mm

mm

mm

mm

No./mm

Cable
weight
(Approx.)
kg/km

Telephone and
Instrumentation Cable

1.5

7/0.52

1.56

0.5

1.0

1.2

13.6

0.6

205

2.5

7/0.67

2.01

0.5

1.0

1.3

14.8

0.6

255

7/0.85

2.55

0.5

1.0

1.3

16.0

0.7

320

7/1.04

3.12

0.5

1.0

1.4

17.4

0.7

410

10

7/1.35

4.05

0.5

1.0

1.5

19.6

0.8

570

16

7/1.70

5.10

0.5

1.0

1.6

22.1

0.9

795

25

7/2.14

6.42

0.5

1.2

1.7

26.0

1.1

1170

35

7/2.52

7.56

0.5

1.2

1.8

28.6

1.2

1520

50

19/1.78

8.90

0.5

1.4

2.0

32.8

1.4

2010

70

19/2.14

10.7

0.5

1.4

2.1

36.9

1.5

2730

95

19/2.52

12.6

0.5

1.6

2.3

42.7

1.7

3730

120

37/2.03

14.2

0.5

1.6

2.5

46.5

1.8

4580

150

37/2.25

15.8

0.5

1.8

2.6

51.1

1.9

5570

185

37/2.52

17.6

0.5

2.0

2.8

56.2

2.0

6890


21

Conductor

Fire
resistant
layer

Radial
thickness
of
insulation

Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Nominal
overall
diam.

Tolerance
of
overall
diam.

Cable
weight
(Approx.)

Size Construction

O.D

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

0.5

1.0

1.2

0.3

14.9

0.6

315

2.5

7/0.67

2.01

0.5

1.0

1.3

0.3

16.1

0.6

375

7/0.85

2.55

0.5

1.0

1.3

0.3

17.3

0.7

450

7/1.04

3.12

0.5

1.0

1.4

0.3

18.7

0.7

550

10

7/1.35

4.05

0.5

1.0

1.5

0.3

20.9

0.8

730

16

7/1.70

5.10

0.5

1.0

1.6

0.3

23.4

0.9

975

25

7/2.14

6.42

0.5

1.2

1.7

0.3

27.3

1.1

1380

35

7/2.52

7.56

0.5

1.2

1.8

0.3

29.9

1.2

1740

50

19/1.78

8.90

0.5

1.4

2.0

0.4

34.6

1.4

2380

70

19/2.14

10.7

0.5

1.4

2.1

0.4

38.7

1.5

3140

95

19/2.52

12.6

0.5

1.6

2.3

0.4

44.5

1.7

4200

120

37/2.03

14.2

0.5

1.6

2.5

0.4

48.3

1.8

5090

150

37/2.25

15.8

0.5

1.8

2.6

0.4

52.9

1.9

6130

185

37/2.52

17.6

0.5

2.0

2.8

0.4

58.0

2.0

7510

kg/km

High Voltage Power Cable

TABLE 25 0.6/1 kV FR-TPYC 0.6/1 kV FR-FA-TPYC

Power & Lighting Cable



Fire
resistant
layer

Radial
thickness
of
insulation

Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Radial
thickness of
protective
covering

Nominal
overall
diam.

Tolerance
of
overall
diam.

Cable
weight
(Approx.)
kg/km

Size Construction

O.D

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

1.5

7/0.52

1.56

0.5

1.0

1.2

0.3

1.0

17.1

0.7

390

2.5

7/0.67

2.01

0.5

1.0

1.3

0.3

1.0

18.3

0.7

460

7/0.85

2.55

0.5

1.0

1.3

0.3

1.0

19.5

0.8

540

7/1.04

3.12

0.5

1.0

1.4

0.3

1.1

21.1

0.8

650

10

7/1.35

4.05

0.5

1.0

1.5

0.3

1.1

23.3

0.9

845

16

7/1.70

5.10

0.5

1.0

1.6

0.3

1.2

26.0

1.0

1110

25

7/2.14

6.42

0.5

1.2

1.7

0.3

1.3

30.1

1.2

1550

35

7/2.52

7.56

0.5

1.2

1.8

0.3

1.3

32.7

1.3

1930

50

19/1.78

8.90

0.5

1.4

2.0

0.4

1.5

38.0

1.5

2640

70

19/2.14

10.7

0.5

1.4

2.1

0.4

1.6

42.3

1.6

3450

95

19/2.52

12.6

0.5

1.6

2.3

0.4

1.7

48.3

1.8

4580

120

37/2.03

14.2

0.5

1.6

2.5

0.4

1.8

52.3

1.9

5520

150

37/2.25

15.8

0.5

1.8

2.6

0.4

1.9

57.1

2.0

6630

185

37/2.52

17.6

0.5

2.0

2.8

0.4

2.1

62.6

2.1

8110


22

Telephone and
Instrumentation Cable

Conductor

Control & Signal Cable

TABLE 26 0.6/1 kV FR-TPYCY 0.6/1 kV FR-FA-TPYCY

High Voltage Power Cable

Power & Lighting Cable

Control & Signal Cable

Telephone and
Instrumentation Cable

23

High Voltage Power Cable

150/250V FA-MPYCY
 

Rated Voltage

150/ 250V

Power & Lighting Cable

Control and Signal Cable


Cable Symbols

MPY, FA-MPY
MPYC, FA-MPYC
MPYCY, FA-MPYCY

Application Standard

Design guideJIS C 3410(2010),IEC 60092-350(2008-02),


IEC 60092-351(2004-04), IEC 60092-353(2001-04),
IEC 60092-359(1999-08), IEC 60092-376(2003-05)
Flame retardantIEC 60332-1& IEC 60332-3-22 Category A (FA-Type)
Max. conductor temperature90

CONSTRUCTION

Control & Signal Cable

Classification Code

Construction Detail

Conductor

Stranded tinned annealed copper wires as per JIS C 3410.

Insulation

EPR as per JIS C 3410,IEC 60092-351

Insulated conductors shall be cabled.

Cabling

Flame retardant & Non-hygroscopic fillers may be used.

Suitable tape(s) may be applied on the cabled core.

Sheath

PVC as per JIS C 3410,IEC 60092-353

Armor

Braid of galvanized steel wires.


Paint

Telephone and
Instrumentation Cable

Protective Covering

Coverage density is minimum 90%.


The white paint shall be painted uniformly on the steel wire
braid
Protective covering Type, paint is dispensable.
PVC as per JIS C 3410.

Outer sheath color : Black

Identification - by number.

Core identification

25

Tolerance
of
overall
diam.

Cable
weight
(Approx.)
kg/km

Size

Construction

O.D

No.

SQ

No./mm

mm

mm

mm

mm

mm

7/0.43

1.29

0.6

1.1

8.7

0.4

85

7/0.43

1.29

0.6

1.1

9.9

0.4

125

7/0.43

1.29

0.6

1.2

11.9

0.5

190

12

7/0.43

1.29

0.6

1.3

15.5

0.7

315

19

7/0.43

1.29

0.6

1.4

18.3

0.8

465

27

7/0.43

1.29

0.6

1.6

22.1

0.9

665

37

7/0.43

1.29

0.6

1.7

24.8

1.0

870

44

7/0.43

1.29

0.6

1.8

28.0

1.2

1060

77

7/0.43

1.29

0.6

2.1

35.9

1.5

1790

TABLE 28 150/250 V MPYC 150/250 V FA-MPYC


Radial
thickness
of
insulation

Radial
thickness
of
sheath

Diam. of
metal wire
braid
armour

Nominal
overall
diam.

Tolerance of
diam. over
sheath &
overall diam.

Cable
weight
(Approx.)

mm

mm

mm

mm

mm

mm

kg/km

7/0.43

1.29

0.6

1.1

0.3

10.0

0.4

155

7/0.43

1.29

0.6

1.1

0.3

11.2

0.4

205

7/0.43

1.29

0.6

1.2

0.3

13.2

0.5

290

12

7/0.43

1.29

0.6

1.3

0.3

16.8

0.7

440

19

7/0.43

1.29

0.6

1.4

0.3

19.6

0.8

615

27

7/0.43

1.29

0.6

1.6

0.3

23.4

0.9

840

37

7/0.43

1.29

0.6

1.7

0.3

26.1

1.0

1070

44

7/0.43

1.29

0.6

1.8

0.3

29.3

1.2

1290

77

7/0.43

1.29

0.6

2.1

0.4

37.7

1.5

2190

Size

Construction

O.D

No.

SQ

No./mm

Conductor

TABLE 29 150/250 V MPYCY 150/250 V FA-MPYCY


Radial
thickness
of
insulation

Radial
thickness
of
sheath

Diam. of
metal wire
braid
armour

Radial
thickness of
protective
covering

Nominal
overall
diam.

Tolerance
of
overall
diam.

mm

mm

mm

mm

mm

mm

mm

7/0.43

1.29

0.6

1.1

0.3

0.9

12.0

0.5

205

7/0.43

1.29

0.6

1.1

0.3

0.9

13.2

0.5

260

7/0.43

1.29

0.6

1.2

0.3

0.9

15.2

0.6

350

12

7/0.43

1.29

0.6

1.3

0.3

1.0

19.0

0.8

525

19

7/0.43

1.29

0.6

1.4

0.3

1.1

22.0

0.9

720

27

7/0.43

1.29

0.6

1.6

0.3

1.2

26.0

1.0

980

37

7/0.43

1.29

0.6

1.7

0.3

1.3

28.9

1.2

1240

44

7/0.43

1.29

0.6

1.8

0.3

1.3

32.1

1.3

1470

77

7/0.43

1.29

0.6

2.1

0.4

1.5

41.1

1.6

2480

No. of
cores

Size

Construction

O.D

No.

SQ

No./mm

Conductor

26

Cable
weight
(Approx.)
kg/km

Telephone and
Instrumentation Cable

No. of
cores

High Voltage Power Cable

Nominal
diam.
over
sheath

Power & Lighting Cable

Radial
thickness
of
sheath

Radial
thickness
of
insulation

Conductor

No. of
cores

Control & Signal Cable

TABLE 27 150/250 V MPY 150/250 V FA-MPY

High Voltage Power Cable

150/250V FA-MPYCYSLA
 

Rated Voltage

150/ 250V

Power & Lighting Cable

Control and Signal Cable


Cable Symbols

MPYCSLA, FA-MPYCSLA
MPYCYSLA, FA-MPYCYSLA
MPYC-S, FA-MPYC-S
MPYCY-S, FA-MPYCY-S

Application Standard

Design guideJIS C 3410(2010),IEC 60092-350(2008-02),


IEC 60092-351(2004-04), IEC 60092-353(2001-04),
IEC 60092-359(1999-08), IEC 60092-376(2003-05)
Flame retardantIEC 60332-1& IEC 60332-3-22 Category A (FA-Type)
Max. conductor temperature90

Control & Signal Cable

CONSTRUCTION
Classification Code

Construction Detail

Conductor

Stranded tinned annealed copper wires as per JIS C 3410.

Insulation

EPR as per JIS C 3410,IEC 60092-351

Insulated conductors shall be cabled.

Cabling

Flame retardant & Non-hygroscopic fillers may be used.

Suitable tape(s) may be applied on the cabled core.

Shielded

SLA

-S

Overall Shielded with Aluminium foil-mylar tape and drain wire


Individual core shielded with copper wire braid

Sheath

PVC as per JIS C 3410,IEC 60092-353

Armor

Braid of galvanized steel wires.

Telephone and
Instrumentation Cable

Paint

Protective Covering

Coverage density is minimum 90%.


The white paint shall be painted uniformly on the steel wire braid
Protective covering Type, paint is dispensable.
PVC as per JIS C 3410.

Outer sheath color : Black

Identification - by number.

Core identification

27

Radial
thickness
of
sheath

Diam. of
metal wire
braid
armour

Nominal
overall
diam.

Tolerance of
diam. over
sheath &
overall diam.

Cable
weight
(Approx.)
kg/km

Size

Construction

O.D

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

7/0.43

1.29

0.6

0.05

1.1

0.3

10.2

0.4

160

7/0.43

1.29

0.6

0.05

1.1

0.3

11.4

0.5

210

7/0.43

1.29

0.6

0.05

1.2

0.3

13.4

0.5

290

12

7/0.43

1.29

0.6

0.05

1.3

0.3

17.0

0.7

444

19

7/0.43

1.29

0.6

0.05

1.4

0.3

19.8

0.8

615

27

7/0.43

1.29

0.6

0.05

1.6

0.3

23.6

0.9

845

37

7/0.43

1.29

0.6

0.05

1.7

0.3

26.3

1.1

1070

44

7/0.43

1.29

0.6

0.05

1.8

0.3

29.5

1.2

1290

TABLE 31 150/250 V MPYCYSLA 150/250 V FA-MPYCYSLA

Size

Construction O.D

Radial
thickness
of
insulation

AL-mylar
tape
thickness

Radial
Diam. of
Radial
thickness metal wire thickness of
protective
braid
of
covering
armour
sheath

Nominal
overall
diam.

Tolerance
of
overall
diam.

Cable
weight
(Approx.)

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

kg/km

7/0.43

1.29

0.6

0.05

1.1

0.3

0.9

12.0

0.5

200

7/0.43

1.29

0.6

0.05

1.1

0.3

0.9

13.4

0.5

260

7/0.43

1.29

0.6

0.05

1.2

0.3

0.9

15.4

0.6

355

12

7/0.43

1.29

0.6

0.05

1.3

0.3

1.0

19.2

0.8

530

19

7/0.43

1.29

0.6

0.05

1.4

0.3

1.1

22.2

0.9

725

27

7/0.43

1.29

0.6

0.05

1.6

0.3

1.2

26.2

1.0

985

37

7/0.43

1.29

0.6

0.05

1.7

0.3

1.3

29.1

1.2

1240

44

7/0.43

1.29

0.6

0.05

1.8

0.3

1.3

32.5

1.3

1490

TABLE 32 150/250 V MPYC-S 150/250 V FA-MPYC-S


Braid wire
diam.
of
shielded

Diam. of
Radial
thickness metal wire
braid
of
armour
sheath

Tolerance of
Cable
diam. over
weight
sheath &
(Approx.)
overall diam.

Size

Construction

O.D

Radial
thickness
of
insulation

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

7/0.43

1.29

0.6

0.12

1.1

0.3

11.4

0.5

180

7/0.43

1.29

0.6

0.12

1.2

0.3

13.1

0.5

305

7/0.43

1.29

0.6

0.12

1.3

0.3

15.5

0.6

445

12

7/0.43

1.29

0.6

0.12

1.4

0.3

20.0

0.8

705

19

7/0.43

1.29

0.6

0.12

1.6

0.3

23.5

0.9

1020

27

7/0.43

1.29

0.6

0.12

1.7

0.3

27.9

1.1

1400

37

7/0.43

1.29

0.6

0.12

1.9

0.3

31.4

1.3

1820

44

7/0.43

1.29

0.6

0.12

2.0

0.4

35.8

1.4

2290

Conductor

No. of
cores

28

Nominal
overall
diam.

kg/km

Telephone and
Instrumentation Cable

Conductor

No. of
cores

High Voltage Power Cable

AL-mylar
tape
thickness

Radial
thickness
of
insulation

Conductor

No. of
cores

Power & Lighting Cable

TABLE 30 150/250 V MPYCSLA 150/250 V FA-MPYCSLA

Control & Signal Cable

High Voltage Power Cable

TABLE 33 150/250 V MPYCY-S 150/250 V FA-MPYCY-S


Conductor

Braid
wire diam.
of
shielded

Radial
thickness
of
sheath

Diam. of
metal wire
braid
armour

Radial
thickness
of
protective
covering

Nominal
overall
diam.

Tolerance
of diam.
Cable
over
weight
sheath &
(Approx.)
overall
diam.

Power & Lighting Cable

Size

Construction

O.D

Radial
thickness
of
insulation

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

7/0.43

1.29

0.6

0.12

1.1

0.3

0.9

13.4

0.5

235

7/0.43

1.29

0.6

0.12

1.2

0.3

0.9

15.1

0.6

365

7/0.43

1.29

0.6

0.12

1.3

0.3

1.0

17.7

0.7

525

12

7/0.43

1.29

0.6

0.12

1.4

0.3

1.1

22.4

0.9

815

19

7/0.43

1.29

0.6

0.12

1.6

0.3

1.2

26.1

1.0

1160

27

7/0.43

1.29

0.6

0.12

1.7

0.3

1.3

30.7

1.2

1570

37

7/0.43

1.29

0.6

0.12

1.9

0.3

1.4

34.4

1.4

2030

44

7/0.43

1.29

0.6

0.12

2.0

0.4

1.5

39.0

1.6

2550

No. of
cores

Control & Signal Cable


Telephone and
Instrumentation Cable

29

kg/km

Telephone and
Instrumentation Cable

30

Control & Signal Cable

Power & Lighting Cable

High Voltage Power Cable

High Voltage Power Cable

150/250V FR-FA-MPYCY
 

Rated Voltage

150/ 250V

Power & Lighting Cable

Control and Signal Cable


Cable Symbols

FR-MPY, FR-FA-MPY
FR-MPYC, FR-FA-MPYC
FR-MPYCY, FR-FA-MPYCY

Application Standard

Design guideJIS C 3410(2010),IEC 60092-350(2008-02),


IEC 60092-351(2004-04), IEC 60092-353(2001-04),
IEC 60092-359(1999-08), IEC 60092-376(2003-05)
Flame retardantIEC 60332-1& IEC 60332-3-22 Category A (FA-Type)
Fire resistantIEC 60331 1/2
Max. conductor temperature90

Control & Signal Cable

CONSTRUCTION
Classification Code

Construction Detail

Conductor

Stranded tinned annealed copper wires as per JIS C 3410.

Insulation

EPR as per JIS C 3410,IEC 60092-351

Insulated conductors shall be cabled.

Cabling

Flame retardant & Non-hygroscopic fillers may be used.

Suitable tape(s) may be applied on the cabled core.

Sheath

PVC as per JIS C 3410,IEC 60092-353

Armor

Braid of galvanized steel wires.


Paint

Telephone and
Instrumentation Cable

Protective Covering

Coverage density is minimum 90%.


The white paint shall be painted uniformly on the steel wire braid
Protective covering Type, paint is dispensable.
PVC as per JIS C 3410.

Outer sheath color : Gray

Identification - by number.

Core identification

31

Radial
thickness
of
sheath

Nominal
overall
diam.

Tolerance
of
overall
diam.

Cable
weight
(Approx.)

Size

Construction

O.D

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

7/0.43

1.29

0.5

0.6

1.1

10.9

0.5

120

7/0.43

1.29

0.5

0.6

1.2

12.8

0.6

185

7/0.43

1.29

0.5

0.6

1.3

15.4

0.7

285

12

7/0.43

1.29

0.5

0.6

1.5

20.5

0.9

485

19

7/0.43

1.29

0.5

0.6

1.6

24.2

1.0

705

27

7/0.43

1.29

0.5

0.6

1.8

29.3

1.2

1010

37

7/0.43

1.29

0.5

0.6

2.0

33.1

1.4

1330

44

7/0.43

1.29

0.5

0.6

2.1

37.4

1.6

1630

kg/km

TABLE 35 150/250 V FR-MPYC 150/250 V FR-FA-MPYC


Conductor

No. of
cores

Fire
resistant
layer

Radial
thickness
of
insulation

Radial
thickness
of
sheath

Diam. of
metal wire
braid
armour

Nominal
overall
diam.

Tolerance
of
overall
diam.

Cable
weight
(Approx.)

Size

Construction

O.D

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

7/0.43

1.29

0.5

0.6

1.1

0.3

12.2

0.5

210

7/0.43

1.29

0.5

0.6

1.2

0.3

14.1

0.6

290

7/0.43

1.29

0.5

0.6

1.3

0.3

16.7

0.7

410

12

7/0.43

1.29

0.5

0.6

1.5

0.3

21.8

0.9

650

19

7/0.43

1.29

0.5

0.6

1.6

0.3

25.5

1.0

900

27

7/0.43

1.29

0.5

0.6

1.8

0.3

30.6

1.2

1250

37

7/0.43

1.29

0.5

0.6

2.0

0.4

34.9

1.4

1700

44

7/0.43

1.29

0.5

0.6

2.1

0.4

39.2

1.6

2040

kg/km

TABLE 36 150/250 V FR-MPYCY 150/250 V FR-FA-MPYCY


Conductor

No. of
cores

Fire
resistant
layer

Radial
thickness
of
insulation

Radial
thickness
of
sheath

Diam. of
metal wire
braid
armour

Radial
thickness
of
protective
covering

Nominal
overall
diam.

Tolerance
of
overall
diam.

Cable
weight
(Approx.)

Size

Construction

O.D

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

7/0.43

1.29

0.5

0.6

1.1

0.3

0.9

14.2

0.6

265

7/0.43

1.29

0.5

0.6

1.2

0.3

1.0

16.3

0.7

360

7/0.43

1.29

0.5

0.6

1.3

0.3

1.0

18.9

0.8

490

12

7/0.43

1.29

0.5

0.6

1.5

0.3

1.1

24.2

1.0

765

19

7/0.43

1.29

0.5

0.6

1.6

0.3

1.2

28.1

1.1

1050

27

7/0.43

1.29

0.5

0.6

1.8

0.3

1.4

33.6

1.3

1450

37

7/0.43

1.29

0.5

0.6

2.0

0.4

1.5

38.3

1.5

1970

44

7/0.43

1.29

0.5

0.6

2.1

0.4

1.6

42.8

1.7

2360

32

High Voltage Power Cable

Radial
thickness
of
insulation

Power & Lighting Cable

Fire
resistant
layer

kg/km

Telephone and
Instrumentation Cable

Conductor

No. of
cores

Control & Signal Cable

TABLE 34 150/250 V FR-MPY 150/250 V FR-FA-MPY

High Voltage Power Cable

Power & Lighting Cable

Control & Signal Cable

Telephone and
Instrumentation Cable

33

High Voltage Power Cable

150/250V FA-TTYCY



Rated Voltage

150/ 250V

Power & Lighting Cable

Telephone and Instrumentation Cable


Cable Symbols

TTY, FA-TTY
TTYC, FA-TTYC
TTYCY, FA-TTYCY

Application Standard

Design guideJIS C 3410(2010),IEC 60092-350(2008-02),


IEC 60092-351(2004-04), IEC 60092-353(2001-04),
IEC 60092-359(1999-08), IEC 60092-376(2003-05)
Flame retardantIEC 60332-1& IEC 60332-3-22 Category A (FA-Type)
Max. conductor temperature70

CONSTRUCTION

Control & Signal Cable

Classification Code
Conductor
Insulation Y
Cabling

Construction Detail
Stranded annealed copper wires as per JIS C 3410.
PVC as per JIS C 3410,IEC 60092-353
Insulated conductors shall be cabled.

Flame retardant & Non-hygroscopic fillers may be used.

Suitable tape(s) may be applied on the cabled core.

Sheath Y
Armor C

Paint

Protective Covering Y

Telephone and
Instrumentation Cable


Core identification

PVC as per JIS C 3410,IEC 60092-353


Braid of galvanized steel wires.
Coverage density is minimum 90%.
The white paint shall be painted uniformly on the steel wire braid
Protective covering Type, paint is dispensable.
PVC as per JIS C 3410.
Outer sheath color : Black
1Pair :Black, White
1Triple :Black, White, Red
1Quad :Black, White, Red, Green
Mult-pairs : The insulation for each pair shall be colored with one
black and one white with printed arabic numberals on insulation
identification

35

O.D

No.

SQ

No./mm

mm

mm

mm

mm

mm

0.75

7/0.37

1.11

0.6

1.0

7.9

0.4

65

1T

0.75

7/0.37

1.11

0.6

1.1

8.6

0.4

85

1Q

0.75

7/0.37

1.11

0.6

1.1

9.3

0.4

105

0.75

7/0.37

1.11

0.6

1.3

14.2

0.6

205

14

0.75

7/0.37

1.11

0.6

1.4

16.9

0.7

310

10

20

0.75

7/0.37

1.11

0.6

1.5

21.7

0.9

465

14

28

0.75

7/0.37

1.11

0.6

1.6

23.5

1.0

585

19

38

0.75

7/0.37

1.11

0.6

1.7

26.4

1.1

755

24

48

0.75

7/0.37

1.11

0.6

1.9

31.9

1.3

1030

30

60

0.75

7/0.37

1.11

0.6

2.0

34.0

1.4

1220

37

74

0.75

7/0.37

1.11

0.6

2.1

36.9

1.5

1450

48

96

0.75

7/0.37

1.11

0.6

2.3

42.8

1.7

1910

Cable
weight
(Approx.)

No.

Cable
weight
(Approx.)
kg/km

TABLE 38 150/250V TTYC 150/250V FA-TTYC


Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Nominal
overall
diam.

Tolerance
of diam.
over sheath &
overall diam.

Size

Construction

O.D

Radial
thickness
of
insulation

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

0.75

7/0.37

1.11

0.6

1.0

0.3

9.2

0.4

130

1T

0.75

7/0.37

1.11

0.6

1.1

0.3

9.9

0.4

160

1Q

0.75

7/0.37

1.11

0.6

1.1

0.3

10.6

0.4

180

0.75

7/0.37

1.11

0.6

1.3

0.3

15.5

0.6

320

14

0.75

7/0.37

1.11

0.6

1.4

0.3

18.2

0.7

445

10

20

0.75

7/0.37

1.11

0.6

1.5

0.3

23.0

0.9

640

14

28

0.75

7/0.37

1.11

0.6

1.6

0.3

24.8

1.0

775

19

38

0.75

7/0.37

1.11

0.6

1.7

0.3

27.7

1.1

965

24

48

0.75

7/0.37

1.11

0.6

1.9

0.4

33.7

1.3

1380

30

60

0.75

7/0.37

1.11

0.6

2.0

0.4

35.8

1.4

1590

37

74

0.75

7/0.37

1.11

0.6

2.1

0.4

38.7

1.5

1860

48

96

0.75

7/0.37

1.11

0.6

2.3

0.4

44.6

1.7

2380

No.
of
pairs

No.
of
cores

No.

Conductor

36

High Voltage Power Cable

Tolerance
of
overall
diam.

Construction

Conductor

kg/km

Control & Signal Cable

Nominal
diam.
over
sheath

Size

No.
of
cores

Telephone and
Instrumentation Cable

Radial
thickness
of
sheath

Radial
thickness
of
insulation

No.
of
pairs

Power & Lighting Cable

TABLE 37 150/250V TTY 150/250V FA-TTY

High Voltage Power Cable

TABLE 39 150/250V TTYCY 150/250V FA-TTYCY


No.
of
pairs

Conductor
No.
of
cores Size Construction O.D

Radial
thickness
of
insulation

Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Radial
thickness of
protective
covering

Nominal
overall
diam.

Tolerance
of
overall
diam.

Cable
weight
(Approx.)

Power & Lighting Cable

No.

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

0.75

7/0.37

1.11

0.6

1.0

0.3

0.8

11.0

0.4

170

1T

0.75

7/0.37

1.11

0.6

1.1

0.3

0.8

11.7

0.5

200

1Q

0.75

7/0.37

1.11

0.6

1.1

0.3

0.9

12.6

0.5

230

0.75

7/0.37

1.11

0.6

1.3

0.3

1.0

17.7

0.7

400

14

0.75

7/0.37

1.11

0.6

1.4

0.3

1.1

20.6

0.8

545

10

20

0.75

7/0.37

1.11

0.6

1.5

0.3

1.2

25.6

1.0

775

14

28

0.75

7/0.37

1.11

0.6

1.6

0.3

1.2

27.4

1.1

920

19

38

0.75

7/0.37

1.11

0.6

1.7

0.3

1.3

30.5

1.2

1140

24

48

0.75

7/0.37

1.11

0.6

1.9

0.4

1.4

36.7

1.5

1610

30

60

0.75

7/0.37

1.11

0.6

2.0

0.4

1.5

39.2

1.6

1870

37

74

0.75

7/0.37

1.11

0.6

2.1

0.4

1.6

42.3

1.6

2180

48

96

0.75

7/0.37

1.11

0.6

2.3

0.4

1.7

48.4

1.8

2760

Control & Signal Cable


Telephone and
Instrumentation Cable

37

kg/km

Telephone and
Instrumentation Cable

38

Control & Signal Cable

Power & Lighting Cable

High Voltage Power Cable

High Voltage Power Cable

150/250V FA-TTYCYSLA
 

Rated Voltage

150/ 250V

Power & Lighting Cable

Telephone and Instrumentation Cable


Cable Symbols

TTYCSLA, FA-TTYCSLA
TTYCYSLA, FA-TTYCYSLA

Application Standard

Design guideJIS C 3410(2010),IEC 60092-350(2008-02),


IEC 60092-351(2004-04), IEC 60092-353(2001-04),
IEC 60092-359(1999-08), IEC 60092-376(2003-05)
Flame retardantIEC 60332-1& IEC 60332-3-22 Category A (FA-Type)
Max. conductor temperature70

CONSTRUCTION
Classification Code

Control & Signal Cable

Conductor
Insulation Y
Cabling

Construction Detail
Stranded annealed copper wires as per JIS C 3410.
PVC as per JIS C 3410,IEC 60092-353
Insulated conductors shall be cabled.

Flame retardant & Non-hygroscopic fillers may be used.

Suitable tape(s) may be applied on the cabled core.

Shielded SLA
Sheath Y
Armor C

Paint

Protective Covering Y

Telephone and
Instrumentation Cable


Core identification

Overall Shielded with Aluminium foil-mylar tape and drain wire


PVC as per JIS C 3410,IEC 60092-353
Braid of galvanized steel wires.
Coverage density is minimum 90%.
The white paint shall be painted uniformly on the steel wire braid
Protective covering Type, paint is dispensable.
PVC as per JIS C 3410.
Outer sheath color : Black
1Pair :Black, White
1Triple :Black, White, Red
1Quad :Black, White, Red, Green
Mult-pairs : The insulation for each pair shall be colored with one
black and one white with printed arabic numberals on insulation
identification

39

Nominal
overall
diam.

Tolerance
Cable
of diam.
over sheath
weight
(Approx.)
&
overall diam.

O.D

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

0.75

7/0.37

1.11

0.6

0.05

1.0

0.3

9.4

0.4

140

1T

0.75

7/0.37

1.11

0.6

0.05

1.1

0.3

10.1

0.4

170

1Q

0.75

7/0.37

1.11

0.6

0.05

1.1

0.3

10.8

0.4

190

0.75

7/0.37

1.11

0.6

0.05

1.3

0.3

15.7

0.6

335

14

0.75

7/0.37

1.11

0.6

0.05

1.4

0.3

18.4

0.7

460

10

20

0.75

7/0.37

1.11

0.6

0.05

1.6

0.3

23.4

0.9

665

14

28

0.75

7/0.37

1.11

0.6

0.05

1.6

0.3

25.0

1.0

790

19

38

0.75

7/0.37

1.11

0.6

0.05

1.7

0.3

27.9

1.1

985

24

48

0.75

7/0.37

1.11

0.6

0.05

1.9

0.4

33.9

1.4

1400

30

60

0.75

7/0.37

1.11

0.6

0.05

2.0

0.4

36.0

1.4

1610

37

74

0.75

7/0.37

1.11

0.6

0.05

2.1

0.4

38.9

1.6

1880

48

96

0.75

7/0.37

1.11

0.6

0.05

2.3

0.4

44.8

1.7

2410

No.

kg/km

TABLE 41 150/250V TTYCYSLA 150/250V FA-TTYCYSLA


No.
of
pairs

Radial
Conductor
thickness
No.
of
of
cores Size Construction O.D insulation

AL-mylar
tape
thickness

Radial
thickness
of
sheath

Radial
Tolerance
Diam. of
thickness Nominal
of
metal
overall
of
overall
wire braid
protective diam.
diam.
armour
covering

Cable
weight
(Approx.)

No.

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

0.75

7/0.37

1.11

0.6

0.05

1.0

0.3

0.8

11.2

0.4

180

1T

0.75

7/0.37

1.11

0.6

0.05

1.1

0.3

0.9

12.1

0.5

215

1Q

0.75

7/0.37

1.11

0.6

0.05

1.1

0.3

0.9

12.8

0.5

240

0.75

7/0.37

1.11

0.6

0.05

1.3

0.3

1.0

17.9

0.7

410

14

0.75

7/0.37

1.11

0.6

0.05

1.4

0.3

1.1

20.8

0.8

560

10

20

0.75

7/0.37

1.11

0.6

0.05

1.6

0.3

1.2

26.0

1.0

805

14

28

0.75

7/0.37

1.11

0.6

0.05

1.6

0.3

1.2

27.6

1.1

935

19

38

0.75

7/0.37

1.11

0.6

0.05

1.7

0.3

1.3

30.7

1.2

1160

24

48

0.75

7/0.37

1.11

0.6

0.05

1.9

0.4

1.4

36.9

1.5

1630

30

60

0.75

7/0.37

1.11

0.6

0.05

2.0

0.4

1.5

39.4

1.6

1890

37

74

0.75

7/0.37

1.11

0.6

0.05

2.1

0.4

1.6

42.5

1.6

2200

48

96

0.75

7/0.37

1.11

0.6

0.05

2.3

0.4

1.7

48.6

1.7

2790

40

High Voltage Power Cable

Diam. of
metal
wire braid
armour

Construction

Conductor

kg/km

Control & Signal Cable

Radial
thickness
of
sheath

Size

No.
of
cores

Telephone and
Instrumentation Cable

AL-mylar
tape
thickness

Radial
thickness
of
insulation

No.
of
pairs

Power & Lighting Cable

TABLE 40 150/250V TTYCSLA 150/250V FA-TTYCSLA

High Voltage Power Cable

150/250V FA-TTYCY-SLA
 


Rated Voltage

150/ 250V

Power & Lighting Cable

Telephone and Instrumentation Cable


Cable Symbols

TTYC-SLA, FA-TTYC-SLA
TTYCY-SLA, FA-TTYCY-SLA

Application Standard

Design guideJIS C 3410(2010),IEC 60092-350(2008-02),


IEC 60092-351(2004-04), IEC 60092-353(2001-04),
IEC 60092-359(1999-08), IEC 60092-376(2003-05)
Flame retardantIEC 60332-1& IEC 60332-3-22 Category A (FA-Type)
Max. conductor temperature70

CONSTRUCTION
Classification Code

Control & Signal Cable

Conductor
Insulation Y
Cabling

Construction Detail
Stranded annealed copper wires as per JIS C 3410.
PVC as per JIS C 3410,IEC 60092-353
Insulated conductors shall be cabled.

Flame retardant & Non-hygroscopic fillers may be used.

Suitable tape(s) may be applied on the cabled core.

Shielded -SLA
Sheath Y
Armor C

Paint

Telephone and
Instrumentation Cable

Protective Covering Y


Core identification

Individual pairs shielded - with Aluminium foil-mylar tape and


drain wire.
PVC as per JIS C 3410,IEC 60092-353
Braid of galvanized steel wires.
Coverage density is minimum 90%.
The white paint shall be painted uniformly on the steel wire braid
Protective covering Type, paint is dispensable.
PVC as per JIS C 3410.
Outer sheath color : Black
1Pair :Black, White
1Triple :Black, White, Red
1Quad :Black, White, Red, Green
Mult-pairs : The insulation for each pair shall be colored with one
black and one white with printed arabic numberals on insulation
identification

41

AL-mylar
tape
thickness

Radial
thickness
of
sheath

Diam. of
metal
wire braid
armour

Nominal
overall
diam.

mm

mm

mm

mm

mm

mm

mm

7/0.37

1.11

0.6

0.05

1.3

0.3

17.3

0.7

380

0.75

7/0.37

1.11

0.6

0.05

1.5

0.3

20.8

0.8

545

20

0.75

7/0.37

1.11

0.6

0.05

1.7

0.3

26.5

1.1

805

14

28

0.75

7/0.37

1.11

0.6

0.05

1.8

0.3

28.9

1.2

980

19

38

0.75

7/0.37

1.11

0.6

0.05

1.9

0.4

32.7

1.3

1320

24

48

0.75

7/0.37

1.11

0.6

0.05

2.1

0.4

38.4

1.5

1710

30

60

0.75

7/0.37

1.11

0.6

0.05

2.2

0.4

40.9

1.6

1970

37

74

0.75

7/0.37

1.11

0.6

0.05

2.3

0.4

44.1

1.7

2300

48

96

0.75

7/0.37

1.11

0.6

0.05

2.6

0.4

50.9

1.9

2960

No.

SQ

No./mm

0.75

14

10

kg/km

TABLE 43 150/250V TTYCY-SLA 150/250V FA-TTYCY-SLA


No.
No.
of
of
pairs cores

Size Construction

Radial
thickness
of
O.D insulation

Conductor

Diam. of
Radial
AL-mylar
metal
thickness
tape
wire braid
of
thickness
armour
sheath

Radial
thickness
of protective
covering

Nominal
overall
diam.

Tolerance
of
overall
diam.

Cable
weight
(Approx.)

No.

No.

SQ

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

0.75

7/0.37

1.11

0.6

0.05

1.3

0.3

1.0

19.5

0.8

465

14

0.75

7/0.37

1.11

0.6

0.05

1.5

0.3

1.1

23.2

0.9

660

10

20

0.75

7/0.37

1.11

0.6

0.05

1.7

0.3

1.3

29.3

1.2

970

14

28

0.75

7/0.37

1.11

0.6

0.05

1.8

0.3

1.3

31.7

1.3

1160

19

38

0.75

7/0.37

1.11

0.6

0.05

1.9

0.4

1.4

35.7

1.4

1540

24

48

0.75

7/0.37

1.11

0.6

0.05

2.1

0.4

1.6

42.0

1.6

2020

30

60

0.75

7/0.37

1.11

0.6

0.05

2.2

0.4

1.6

44.5

1.7

2300

37

74

0.75

7/0.37

1.11

0.6

0.05

2.3

0.4

1.7

47.9

1.8

2670

48

96

0.75

7/0.37

1.11

0.6

0.05

2.6

0.4

1.9

55.1

1.9

3440

42

kg/km

Control & Signal Cable

No.

Size Construction O.D

Telephone and
Instrumentation Cable

No.
of
cores

High Voltage Power Cable

Tolerance
Cable
of diam.
over sheath
weight
(Approx.)
&
overall diam.

Radial
thickness
of
insulation

Conductor

No.
of
pairs

Power & Lighting Cable

TABLE 42 150/250V TTYC-SLA 150/250V FA-TTYC-SLA

Electric Technical Information


Conductor
Resistance
(20)

Conductor
Size Construction O.D

Plain

AC Test voltage
(5min)

Tinned 6/10kV

Insulation Resistance
(20)

3.6/6kV

0.6/1kV

150/250V

6/10kV

3.6/6kV

0.6/1kV

150/250V

No./mm

mm

/km

/km

V

V

V

M.km

M.km

M.km

M.km

0.75

7/0.37

1.11

26.0

26.7

---

---

---

1500

---

---

---

20

7/0.43

1.29

19.2

19.3

---

---

---

1500

---

---

---

1000(700)

1.5

7/0.52

1.56

12.1

12.2

---

---

3500

---

---

---

1300(1000)

1000

2.5

7/0.67

2.01

7.41

7.56

---

---

3500

---

---

---

1100(900)

---

7/0.85

2.55

4.61

4.70

---

---

3500

---

---

---

1000(800)

---

7/1.04

3.12

3.08

3.11

---

---

3500

---

---

---

800(700)

---

10

7/1.35

4.05

1.83

1.84

---

12000

3500

---

---

1000

700(600)

---

16

7/1.70

5.1

1.15

1.16

21000

12000

3500

---

1100

900

600(500)

---

25

7/2.14

6.42

0.727

0.734

21000

12000

3500

---

1000

800

500(450)

---

35

7/2.52

7.56

0.524

0.529

21000

12000

3500

---

900

700

450(400)

---

50

19/1.78

8.9

0.387

0.391

21000

12000

3500

---

800

700

450(400)

---

70

19/2.14

10.7

0.268

0.270

21000

12000

3500

---

700

600

450(350)

---

95

19/2.52

12.6

0.193

0.195

21000

12000

3500

---

700

500

400(350)

---

120

37/2.03

14.2

0.153

0.154

21000

12000

3500

---

600

450

350(350)

---

150

37/2.25

15.8

0.124

0.126

21000

12000

3500

---

600

400

350(350)

---

185

37/2.52

17.6 0.0991 0.1000

21000

12000

3500

---

500

400

350(350)

---

240

61/2.25

20.3 0.0754 0.0762

21000

12000

3500

---

450

350

350

---

300

61/2.52

22.7 0.0601 0.0607

21000

12000

3500

---

400

350

350

---

mm

Note. the values of ( ) are given for Fire resistant(FR) type cables.

43

44

45

46

Specifications subject to change without notice.