Outdoor unit, PD series
www.airtradecentre.com
VRF PD series outdoor unit type
GMV-PD
GMV-R type VRF heatpump digital scroll inverter outdoor unit
Application
Outdoor Unit
Function
Long refrigerant pipe, the longest connection pipe of certain units can be 150m,
the largest height difference between indoor and outdoor unit can be 50m
Wide outdoor units lineup, including digital compressor series, DC inverter
compressor series
Heat recovery and ultra-low temperature heat-pump series with digital
compressor are available
Precise temperature control with only 0.5'C temperature fluctuation
Powerful and advanced new controller for optional
Refrigerant
R410A
Features
High COP value
Unique oil return patent design
Real time intelligent defrost technology
Accurate refrigerate distributing technology
Wide capacity range from 5kW to 18kW
Space saving outdoor unit
Low noise
Components optimum designed for R410a
Applicable indoor units
Wall mounted types:
Type GMV[L]-R22G/NaA-K
Type GMV[L]-R28G/NaA-K
Type GMV[L]-R36G/NaA-K
Type GMV[L]-R22G/NaB-K
J.02 GMV-PD 1/3 - 2011/3/17 - AA-EN
Type GMV[L]-R28G/NaB-K
Type GMV[L]-R36G/NaB-K
Type GMV[L]-R45G/NaB-K
Type GMV[L]-R22G/NaC-K
Type GMV[L]-R28G/NaC-K
Type GMV[L]-R36G/NaC-K
Type GMV[L]-R45G/NaC-K
Type GMV[L]-R50G/Na-K
Type GMV[L]-R56G/Na-K

Floor/ceiling types:
Type GMV-R28Zd/Na-K
Type GMV-R36Zd/Na-K
Type GMV-R50Zd/Na-K
Type GMV-R71Zd/Na-K
Type GMV-R90Zd/Na-K
Type GMV-R112Zd/Na-K
Type GMV-R125Zd/Na-K
Applicable controller
Centralized controller
Control 64 groups (64 outdoor unit, 1024 indoor units in max)
Central control
Single control or select control
Weely schedule
Malfunction code display
Expanded timer function
Maximum wiring length of 1000m

Mini centralized controller


Control 1 groups (16 indoor units in max)
Group centralized control
Memory restart
Malfunction code display
Key lock function
Order example
GMV-Pd160W/Na-K

GMV-Pd = Type of digitalscroll outdoor unit


160 =160kW, nominal cooling capacity
W = number of comperessors
Na = Refrigerant = R410A
M = Power complement, M = 380V, 3ph~, 50Hz; K = 220V, 1ph,50Hz ~
Specifications
Model
Capacity Power supply Electrical characteristics Noise
Outline Dimension
[mm]
Net.Weight Connecting Pipe
[kW] V-ph-Hz
Rated power input
[kW]
Rated current input
[A]
dB[A] Width
[mm]
Depth
[mm]
Height
[mm]
[kg] [mm]
Cooling Heating Cooling/Heating Cooling/Heating Gas pipe Liquid pipe
GMV[L]-Pd50W/Na-K 5 6
220~240V
1PH-50Hz
1.41/1.53 6.5/7.0 56 950 340 660 59 12.7 6.35
GMV[L]-Pd70W/Na-K 7 8 2.0/1.86 9.2/8.5 57 950 340 840 75 15.9 9.52
GMV[L]-Pd80W/Na-K 8 9 2.3/2.25 10.6/10.3 57 950 340 840 80 15.9 9.52
GMV[L]-Pd100W/Na-K 10 11 2.85/2.75 13.1/12.6 58 1100 340 1250 90 15.9 9.52
GMV[L]-Pd120W/Na-K 12 14 3.75/3.65 17.2/16.7 58 1100 340 1250 120 15.9 9.52
GMV[L]-Pd140W/Na-K 14 16 4.25/4.05 19.47/18.54 58 1100 340 1250 135 15.9 9.52
GMV[L]-Pd120W/Na-M 12 14
380~415V
3PH-50Hz
3.75/3.65 5.76/5.6 58 1100 340 1250 120 15.9 9.52
GMV[L]-Pd140W/Na-M 14 16 4.35/4.06 6.74/6.29 58 1100 340 1250 135 15.9 9.52
GMV[L]-Pd160W/Na-M 16 18 5.0/5.1 7.7/7.8 58 1100 340 1250 140 19.05 9.52
GMV[L]-Pd200W/Na-M 20 23 6.1/6.3 9.4/9.6 60 990 905 1772 180 19.05 9.52
GMV[L]-Pd280W/Na-M 28 30 8.75/8.25 13.4/12.7 60 990 905 1772 230 22.2 9.52
GMV[L]-Pd300W/Na-M 30 33,50 9.6/9.28 14.7/14.2 60 990 905 1772 230 22.2 9.52