Академический Документы
Профессиональный Документы
Культура Документы
SDR Configuration
Version
Date
Author
Approved By
Remarks
SDR Configuration
CONTENTS
1 TOPLOGY............................................................................................................................................5
2 CONFIGURE TRANSMITION BY LMT.........................................................................................6
2.1
2.2
START LMT...................................................................................................................................6
2.3
SITE CONFIGURATION..................................................................................................................26
4.2
SDR Configuration
4.3
STEP 2: CHECK SOFTWARE (BY OMCR FOR BSC ENGINEER,BY LMT FOR BTS ENGINEER).....54
5.3
5.3.1 CC board...............................................................................................................................54
5.3.2 FS board................................................................................................................................54
5.3.3 UPBG board..........................................................................................................................55
5.3.4 FCE bord...............................................................................................................................55
5.4
5.5
SDR Configuration
Toplogy
Notes
GSM Site ID
67
67
Site IP
116.18.67.100
116.18.67.100
RPU IP of Abis
116.18.1.1
116.18.1.1
67
14596
Vitual IP of CMP
Same as Site ID is recomend
14592+CMP
module
Nuble
116.18.1.1
116.18.1.1
BTS Type
Case
S4/4/4 3/3/3
BCCH
E1 cable
HDLC
TS 1-31
TS 1-31
ML-PPP
Yes
Yes
Port of ML-PPP
192
Multiframe
SDR Configuration
2.1
2.2
Start LMT
2.3
We can make ofline configuration at home for a lot of SDR sites, and save the configration. Connect PC
with BBU for import configuration when SWAP
SDR Configuration
2.3.1
Notes:
BS8700: BS8700_template_2u
BS8800: BS8800_GU360_template_2u
7
SDR Configuration
BS8900: BS8900_GU360_template_2u
2.3.2
Basic attribute
SDR Configuration
Notes:
9
SDR Configuration
Radio Mode : Set GSM for 2G
GSM Station NO: same as SITE ID given by BSC engineer
E1/T1 Medium :Set E1 for IPOE
Rack configuration
BBU Rack
10
SDR Configuration
2.3.3.2
RRU Racke
2.3.3.3
Antenna
11
SDR Configuration
2.3.3.4
2.3.4
E1 Link
2.3.5
HDLC
2.3.6
PPP or ML-PPP
ML-PPP is used in this case, it includes 2 HDLC links (E1 calble)
12
SDR Configuration
2.3.7
Global Port
13
SDR Configuration
2.3.8
IP
2.3.9
SCTP
14
SDR Configuration
Notes:
Local Port ID: Site ID
Remote port: 14592+CMP Module NO.
2.3.10 OMCB Link
15
SDR Configuration
2.3.11 RRU Common Parameters
Creat commom parameters for RRU1~RRU6
16
SDR Configuration
2.3.12 Toplogy
2.3.14 GSM RU
17
SDR Configuration
18
SDR Configuration
19
SDR Configuration
2.4
2.4.1
20
SDR Configuration
2.4.2
21
SDR Configuration
3
3.1
3.1.1
Configuration in OMCR
Transmition Configuration
Configure PCM link in DTB for Layer 1(physical layer)
22
SDR Configuration
3.1.2
RPU IP of EUIP
23
SDR Configuration
Notes:
Port NO: defined by BSC engineer ,1-190 for PPP,191-254 for ML-PPP
3.1.4
3.1.4.1
Notes:
Port NO: defined by BSC engineer,but the number shoul be unique
HDLC NO: use HDLC NO defined in EUIP
24
SDR Configuration
3.1.4.2
PPP Configuration
Notes:
MP NO.Sign: valid for ML-PPP, invalid for PPP
Peer IP: IP address of SITE
MP No: used Port NO defined in EUIP_RPU
3.1.5
25
SDR Configuration
Notes:
Mode NO: used CMP modue NO
Uplink/Down link bandwith : decied by case,for 1 E1 is 2048 ,for 20480 for 10 E1
3.2
3.2.1
Site Configuration
Creat Site
26
SDR Configuration
27
SDR Configuration
Notes:
Site ID: Defined by BSC engineer
Module NO: use the CMP module defined in Rack
28
SDR Configuration
Notes:
Site IP address: IP address of SDR
3.2.2
Creat Cell
29
SDR Configuration
30
SDR Configuration
3.2.3
Creat TRX
31
SDR Configuration
Notes:
Port NO: defined by BSC engineer,a connection information
TRX Group NO: define the TRX to access the DSP of BIPB (IP support) , it is safe that difen different
TRX in different DSP
4
4.1
Configuration in OMCB
Creat Base Station management for SDR
32
SDR Configuration
4.2
33
SDR Configuration
4.3
4.3.1
Rack configuration
34
SDR Configuration
4.3.1.1
BBU rack
35
SDR Configuration
4.3.1.2
RRU rack
4.3.1.3
36
SDR Configuration
4.3.1.4
4.3.2
4.3.2.1
Antenna
Transmition
E1 link
37
SDR Configuration
4.3.2.2
HDLC link
4.3.2.3
PPP
38
SDR Configuration
4.3.2.4
Global Port
4.3.2.5
IP parameter
39
SDR Configuration
4.3.2.6
SCTP
4.3.2.7
OMCB link
4.4
4.4.1
40
SDR Configuration
4.4.2
Toplogy
41
SDR Configuration
4.4.3
GSM RU parameters
42
SDR Configuration
43
SDR Configuration
4.4.4
GSM Sector
44
SDR Configuration
45
SDR Configuration
4.4.5
GSM Carrier
46
SDR Configuration
5
5.1
5.1.1
5.1.1.1
47
SDR Configuration
5.1.1.2
48
SDR Configuration
5.1.2
5.1.2.1
Check the quality of E1 link by telnet command when OMCB link is connected
telnet 192.254.1.16
;telnet to CC in solot 1
CC->ping 116.18.1.1
;ping RPU of Abis,and check whether there is lost packet
CC->BspE1T1ErrPerformStart ;This command is to start check tranmistion quality
CC->E1ErrInfo
;After each 400 second,input this command for view the result. Do this check for
5-7 times, and save the results for report.
tatistic Time:402s
link ES SES
BBE UAS
FAS
CRC
Slip CV
Ebit
------------------------------total stats:
0 10
c
375 182 8367 20d85 0
244e2 4a
value = 86 = 0x56 = 'V'
CC->E1ErrInfo
Statistic Time:420s
link ES
SES
BBE
UAS FAS CRC
------------------------------total stats:
0 10
c
375 194 882a 221ef 0
Slip
CV
Ebit
25cba 4a
49
SDR Configuration
link
ES
SES
BBE
UAS
FAS
CRC
Slip
CV
Ebi
t
E1 link
Error
code
Error
numbe
time(second)
code
Error code
Link
Frame
CRC
Slip
Codec
Error
check
background
unavailable
asynchronize
check
times
abnormal
bits
time(second)
block
time
times
error
times
number
number
(second)
numbe
r
CC->BspE1T1ErrPerformStop ;To stop the check process because this will affect CPU so much.
5.1.2.2
50
SDR Configuration
5.1.3
Only error configuration will lead to HDLC link work abnormally when E1 link is work normally
51
SDR Configuration
5.1.3.1
Only error configuration will lead to PPP link work abnormally when HDLC link is work normally
5.1.4.1 Check PPP link status by LMT (BTS engineer)
Check alarm the same as HDLC link in CC board
5.1.4.2 Check PPP link status by OMCR (BSC engineer)
Check alarm the same as HDLC link in EUIP and CMP board
5.1.5
Only error configuration will lead to SCTP link work abnormally when PPP link is work normally
Check IP address, CMP module number, local port,remote port
5.1.5.1 Check SCTP link status by LMT (BTS engineer)
Check alarm the same as PPP link in CC board
5.1.5.2 Check SCTP link status by OMCR (BSC engineer)
Check alarm the same as PPP link in CMP board
5.1.6
Only error configuration will lead to OMCB link work abnormally when PPP link is work normally
52
SDR Configuration
5.1.6.1
5.1.6.2
53
SDR Configuration
5.2
Step 2: Check Software (by OMCR for BSC engineer,by LMT for BTS engineer)
After download the software by OMCR, BSC engineer shoul check the download result and make sure thar
no software lost
Then, active software for SDR
5.3
5.3.1
It will work normally almost, but we can check the tansmition alarm at this board.between BBU and BSC,
between CC and other boards in BBU
5.3.2
FS board
Alarm Code
solution
Board initial
FS port ID Alarm
notes
54
SDR Configuration
Maybe Fiber cable is broken;
5.3.3
UPBG board
Alarm Code
solution
Board initial
5.3.4
FCE bord
Alarm Code
solution
Board initial
5.4
notes
Alarm Code
solution
Board initial
VSWR Alarm
Check antenna
5.5
notes
notes
55
SDR Configuration
56