trommel sieve waste (TSW), Portland cement, lime, pointing and their
admixtures with TSW in different proportions
Murat Kurudirek
glu
Faculty of Science, Department of Physics, Ataturk University, 25240, Erzurum-Turkey
a r t i c l e i n f o
Article history:
Received 22 December 2009
Accepted 22 December 2009
Keywords:
Trommel sieve waste
Building material
Total mass attenuation coefcient
Total photon interaction cross section
Effective atomic number
Effective electron density
a b s t r a c t
The trommel sieve waste (TSW) which forms during the boron ore production is considered to be a
promising building material with its use as an admixture with Portland cement and is considered to be
an alternative radiation shielding material, also. Thus, having knowledge on the chemical composition
and radiation interaction properties of TSW as compared to other building materials is of importance. In
the present study, chemical compositions of the materials used have been determined using a
wavelength dispersive X-ray uorescence spectrometer (WDXRFS). Also, TSW, some commonly used
building materials (Portland cement, lime and pointing) and their admixtures with TSW have been
investigated in terms of total mass attenuation coefcients (m=r), photon interaction cross sections (s
t
),
effective atomic numbers Z
eff
and effective electron densities N
e
by using X-rays at 22.1, 25keV and
g-rays at 88keV photon energies. Possible conclusions were drawn with respect to the variations in
photon energy and chemical composition.
& 2009 Elsevier Ltd. All rights reserved.
1. Introduction
Boron which is known to be found in nature especially in
boron reserves has been abundantly deposited in Turkey where
the boron reserves constitute about 54% of all boron reserves
available in the world. It has a large use in many technological
applications especially in industry, medicine and radiation
physics. However, during the boron ore production the trommel
sieve waste which has an amount of about 2.510
5
ton/yr forms
in the reactor (Boncukc-uo
glu et al.,
2002b; Singh and Garg, 1999; Erdogan et al., 1994; Boncukc-uoglu
et al., 1998). Element or oxide component concentration deter-
mination in TSW and building materials is of vital importance
because of the fact that their admixtures in different percentages
were used as alternative building materials. Thus, having knowl-
edge on the elemental or oxide composition of these materials
may be used to estimate the effect of each oxide component to
some physical, chemical and mechanical properties of concrete.
Using a multi-element technique capable of determining element
and oxide concentrations simultaneously will be more preferable
because a large number of elements are routinely analyzed in
various types of materials. The easy preparation of sample, small
amount of sample needed for analysis, fast determination, easily
automated procedure and non-destructive methodology make
XRF the method of choice for many industrial, biological,
medicalyetc. analyses. In the present study, the chemical
compositions of the used materials were determined by wave-
length dispersive X-ray uorescence (WDXRF) technique.
Apart from the use as building material, the Portland cement,
lime, pointing and their mixes with TSW are of interest in
radiation shielding. From this point of view, it is of importance to
determine the radiation interaction parameters in these materials
in terms of total mass attenuation coefcients, photon interaction
cross sections, effective atomic numbers and effective electron
densities. These parameters are generally used to determine the
penetration of X-ray and gamma ray photons in matter.
ARTICLE IN PRESS
Contents lists available at ScienceDirect
journal homepage: www.elsevier.com/locate/apradiso
Applied Radiation and Isotopes
0969-8043/$ - see front matter & 2009 Elsevier Ltd. All rights reserved.
doi:10.1016/j.apradiso.2009.12.039
m=r
c
N
A
P
i
w
i
=A
i
b=atom 2
where m=r
c
is the mass attenuation coefcient of the material
and A
i
is the atomic weight of the ith element.
The attenuation cross section values of TSW and building
materials were then interpolated in the attenuation cross section
values generated from WinXCom at the selected energy to
calculate the effective atomic number (Z
eff
) using the following
logarithmic interpolation formula (Singh et al., 2007)
Z
eff
Z
1
logs
2
logs Z
2
logslogs
1
logs
2
logs
1
3
where s
1
and s
2
are the elemental cross sections b=atom in
between which the atomic cross section s of the material lies and
Z
1
and Z
2
are the atomic numbers of the elements corresponding
to the cross sections s
1
and s
2
, respectively.
Also, the effective electron density is expressed by the
following relation (Manohara et al., 2008b);
N
E
N
A
nZ
eff
P
i
n
i
A
i
N
A
Z
eff
/AS
electrons=g 4
where /AS is the average atomic mass of the material. Thus,
using the values of Z
eff
obtained from logarithmic interpolation in
Eq. (4), one can calculate the values of N
e
by using Eq. (4).
3. Calculations
Mass attenuation coefcients of the given materials have been
calculated by the WinXCom program. This program which is
based on the DOS-based compilation XCom (Berger and Hubbell,
19871999) provides total mass attenuation coefcient and total
attenuation cross section data for about 100 elements as well as
partial cross sections for incoherent and coherent scattering,
photoelectric absorption and pair production at energies from
1keV to 100GeV (Gerward et al., 2004). The obtained values of
mass attenuation coefcients were then used to calculate total
interaction cross sections, effective atomic numbers and effective
electron densities. To get more accurate theoretical estimations,
the concentration values of components present in the TSW and
building materials which were experimentally determined by
wavelength dispersive X-ray uorescence spectrometer in this
study were used.
4. Experimental
4.1. Sample preparation
The samples were ground in a SPEX mill with 25ml stainless-
steel cup and balls to minimize the grain sizes and therefore to
reduce the particle size effect on the X-ray intensity. Samples
were sieved in o45mm scaled sieves to ensure particle size
homogeneity in the sample. Prior to analysis, samples were
pressed into pellets having a diameter of 3.1cm under the
pressure of 20ton per cm
2
in a SPEX Pmax hydraulic press. This
progress provided a fairly smooth surface and so minimized the
errors originated from improper surface of samples.
4.2. Measurements
4.2.1. WDXRFS
Elements, in a wide range, from Be to U, can be analyzed in a
variety of sample types and in the concentration range from 100%
M. Kurudirek et al. / Applied Radiation and Isotopes 68 (2010) 10061011 1007
ARTICLE IN PRESS
down to the sub-ppm-level. Samples were exposed to X-rays from
a rhodium tube. The measurements were carried out using a
Rigaku ZSX 100e wavelength dispersive X-ray uorescence
spectrometer with a rhodium target X-ray tube controlled by a
computer system, 4kW generator, a rotating twelve-position
sample holder, ten-position crystal changer, proportional ow
gas and scintillation detection (Fig. 1). All the experimental
parameters were selected and operated via computer except for
the sample preparation. Samples were analyzed in vacuum
atmosphere without exposing to any chemical treatment. Each
samples was analyzed three times to increase sensitivity. All
results were expressed in terms of mean7standard deviation.
4.2.1.1. SQX advanced semi-quantitative software. When the ele-
ments or oxides present in a sample are unknown, a qualitative
analysis is generally carried out to determine the unknown
components in the sample. Semi-quantitative analysis is a quali-
tative analysis that carries out quantication to some extent.
Rigaku
1
has improved their semi-quantitative software package
further with the introduction of SQX. A fundamental parameters
program to calculate semi-quantitative analysis values using
built-in sensitivity libraries for components detected by the
qualitative analysis is called SQX.
Reference X-ray intensities are necessary for the X-ray
uorescence analysis. Standard samples are generally used to
create calibration curves, but in some cases standard samples that
have concentrations similar to those of unknown samples are not
available. In such cases, the fundamental parameters quantica-
tion method can be used to perform quantitative analyses without
standard samples. When components in a sample and their
concentrations are given, theoretical X-ray intensities can be
calculated. This is called the fundamental parameters method.
The spectrometer sensitivities are obtained from the results of a
sensitivity calculation using the fundamental parameters method.
Sensitivity library is consisted of the collection of those spectro-
meter sensitivity values.
The detection limits were expressed as instrumental limits of
detection (ILD) which is dened as being the minimum net peak
intensity of an analyte, expressed in concentration unit that can
be detected by an instrument in a given analytical context with a
%99.95 condence level (Rousseao, 2001). The following mathe-
matical expression was used to calculate the limits of detection;
ILD
4:65
m
i
I
b
T
b
s
5
where m
i
; I
b
and T
b
are the slope of the sensitivity of the
spectrometer in cps/% for an analyte i, background intensity and
background counting time, respectively (Rousseao, 2001). Table 1
shows concentration values with standard deviations from mean
values.
4.2.2. Transmission experiments
In the present study, the total mass attenuation coefcients
[m=rcm
2
=g] of the given materials were measured by perform-
ing transmission experiments in a narrow beam good geometry
set-up. The beam path was aligned using a laser. The photons
emitted from the radioactive point source
109
Cd of 5mCi
(135MBq) strength were well collimated and suitably detected.
A high resolution liquid nitrogen cooled Si(Li) detector
(FWHM=160eV for the Mn-Ka line at 5.9keV, an active area of
12mm
2
, a sensitive crystal depth of 3mm, a beryllium window of
0.025mm thickness) coupled to 4k multichannel analyzer was
employed to detect 22.1, 25 and 88keV. The detector was
shielded by a graded lter of Pb (4.2mm), Fe (1.1mm) and
Al (1mm) to prevent radiation scattered by nearby objects and
also radiation such as L X-rays from the Pb mask, environmental
background and background arising from the scattered radiation
due to sample holder. The spectra were recorded using a PC-based
multichannel analyzer, supplied by CANBERRA, USA. The mea-
surements were performed three times for each sample. Each
spectrum was recorded for sufcient time to accumulate an
adequate number of counts under the photo peak to limit the
uncertainty of o1%. The samples were placed one by one
between the source and the detector.
The maximum errors in total mass attenuation coefcients
were calculated from errors in incident (I
0
) and transmitted (I)
intensities and areal density (t) using the propagation of error
formula
D
m
r
1
t
DI
0
I
0
2
DI
I
2
In
I
0
I
2
Dt
t
2
s
6
where DI
0
, DI and Dt are the errors in the intensities I
0
, I and
thickness t of the sample, respectively. Estimated error in the
experimental measurement was less than 10%.
5. Results and discussion
The experimental values of the total mass attenuation
coefcients obtained from the measured incident (I
0
) and
transmitted (I) X- and g-ray intensities are enlisted in Table 2
along with the theoretical values, calculated using the WinXCom
computer program. In general, the experimental values show
good agreement with the theoretical values within the estimated
error 010%. Some disagreements in m=r values were observed for
Portland cement at 22.1 and 25keV between the experimental
and theoretical values. These discrepancies may be due to the
chemical composition of this material which has oxide
components consisting of elements of very wide spread atomic
Detector
X Ray Tube
Filter
Analyzing Crystal
Primary
Collimator
Secondary
Collimator
Counter
Computer
Sample
2
Fig. 1. Schematic design of WDXRFS.
1
www.rigakumsc.com.
M. Kurudirek et al. / Applied Radiation and Isotopes 68 (2010) 10061011 1008
ARTICLE IN PRESS
numbers and weight fractions of oxide components which vary
from 60% (CaO) down to 16ppm (Ga
2
O
3
). The m=r values were in
general found to be lower along with the increasing photon
energies. This may be attributed to the higher atomic number of
Ca which is more abundant in this material and leads to a higher
density value of lime among the other materials. The m=r values
of TSW were minimum at all energies. This may be due to the
lower weight fraction of Ca present in the TSW material according
to other building materials. For low energies the variations in m=r
are signicant among the given materials due to the domination
of photoelectric process which is of the order of Z
45
.
The experimental total atomic cross sections are listed in
Table 3 along with the theoretical values, as obtained by Eq. (2). It
is observed from Table 3 that the materials having high atomic
number constituent elements with high weight fractions have
signicantly higher values of total interaction cross sections than
other materials. The lime material has the highest value of total
atomic cross sections due to having large weight fractions of Ca as
a constituent element which is a high atomic number element
relative to other elements. One explanation for this could be that
the photoelectric effect is the dominant interaction process for
low energy and high Z elements. The photoelectric cross section is
a Z dependent parameter which is of the order of Z
45
. This state
clearly explains the higher values of total interaction cross
sections for materials having high Z constituent elements with
high weight fractions at 22.1 and 25keV.
Table 4 presents the effective atomic numbers for TSW,
Portland cement, pointing and lime material at different
energies. The value of effective atomic number Z
eff
ranges from
11.5 to 14.1 at 22.1keV, 11.4 to 14.1 at 25keV and 9.4 to 11.9 at
88keV for the given materials. Also, the effective atomic numbers
of Portland cement, lime and pointing material mixed with TSW
in different proportions (25%, 50% and 75%) were tabulated in
Table 1
Chemical composition (%) of TSW, Portland cement, pointing and lime.
Chemical compound TSW P. Cement Pointing Lime
B
2
O
3
13.345870.2816 4.612870.0202 4.951871.1127 3.439770.1390
F 1.027770.0102 0.281170.0154 0.000070.0000 0.250570.2190
Na
2
O 3.072770.0088 0.322470.0074 0.127470.0253 0.034770.0045
MgO 27.214970.1449 3.354270.0015 1.019770.0725 0.66270.0087
Al
2
O
3
1.238970.0108 5.047270.0296 1.988770.0203 0.150870.0021
SiO
2
21.996170.1201 17.872870.0092 9.863270.0383 0.499170.0012
P
2
O
5
0.009970.0002 0.086470.0009 0.035770.0006 0.030270.0005
SO
3
0.580070.0056 3.772570.0023 1.947670.0039 0.664870.0045
Cl 0.095870.0247 0.046370.0054 0.043770.0052 0.033270.0092
K
2
O 0.846770.0065 0.799070.0043 0.243770.0058 0.045070.0005
CaO 28.039870.0555 60.044170.0410 79.519670.7137 93.980270.3495
TiO
2
0.035470.0036 0.296670.0030 0.000070.0000 0.000070.0000
Cr
2
O
3
0.000070.0000 0.000070.0000 0.000070.0000 0.000070.0000
MnO 0.020070.0006 0.058870.0248 0.000070.0000 0.021570.0012
Fe
2
O
3
0.406770.0075 3.058470.0518 0.190970.0094 0.081770.0011
NiO 0.004570.0008 0.061370.0018 0.000070.0000 0.008270.0011
CuO 0.000070.0000 0.044770.0001 0.000070.0000 0.000070.0000
ZnO 0.001470.0012 0.005670.0011 0.000070.0000 0.000070.0000
Ga
2
O
3
0.000070.0000 0.001670.0023 0.000070.0000 0.000070.0000
GeO
2
0.004770.0008 0.000070.0000 0.000070.0000 0.000070.0000
As
2
O
3
0.012170.0030 0.000070.0000 0.000070.0000 0.001370.0012
Rb
2
O 0.023270.0030 0.001870.0011 0.000070.0000 0.000070.0000
SrO 2.014470.0228 0.124370.0008 0.055770.0043 0.036770.0004
PbO 0.001170.0009 0.007970.0009 0.000070.0000 0.000070.0000
Y
2
O
3
0.000070.0000 0.000070.0000 0.000070.0000 0.001470.0013
BaO 0.000070.0000 0.051470.0021 0.000070.0000 0.041970.0022
V
2
O
5
0.000070.0000 0.006170.0042 0.000070.0000 0.031770.0006
ZrO
2
0.000070.0000 0.000070.0000 0.012570.0018 0.000070.0000
Table 2
Total mass attenuation coefcients of TSW and building materials at different
energies.
Energy (keV) Total mass attenuation coefcient [m=r cm
2
=g]
TSW Portland cement Pointing Lime
Exp. Theo. Exp. Theo. Exp. Theo. Exp. Theo.
22.1 2.44 2.33 4.42 3.96 4.51 4.14 4.86 4.43
25 1.73 1.67 3.20 2.81 3.22 2.93 3.40 3.14
88 0.181 0.189 0.210 0.216 0.200 0.218 0.214 0.223
Table 3
Total photon interaction cross sections of TSW and building materials at different
energies.
Energy (keV) Total photon interaction cross section [s
a
(b/atom)]
TSW Portland
cement
Pointing Lime
Exp. Theo. Exp. Theo. Exp. Theo. Exp. Theo.
22.1 71.13 67.92 147.01 131.71 149.07 136.84 163.45 148.99
25 50.43 67.92 106.43 93.46 106.43 96.84 114.35 105.6
88 5.28 5.51 6.98 7.18 6.61 7.21 7.2 7.5
Table 4
Effective atomic numbers of TSW and building materials at different energies.
Energy (keV) Effective atomic number (Z
eff
)
TSW Portland cement Pointing Lime
Exp. Theo. Exp. Theo. Exp. Theo. Exp. Theo.
22.1 11.47 11.33 13.72 13.39 13.77 13.45 14.12 13.77
25 11.44 12.39 13.81 13.41 13.81 13.45 14.09 13.78
88 9.42 9.75 11.64 11.86 11.17 11.89 11.88 12.20
M. Kurudirek et al. / Applied Radiation and Isotopes 68 (2010) 10061011 1009
ARTICLE IN PRESS
Table 5. It was observed from Table 5 that mixing of TSW with
other building materials shows worse properties with respect to
the radiation attenuation properties as the materials mixed with
TSW have lower values of effective atomic numbers as compared
to Portland cement, lime and pointing. According to Hines
expressions (Hine, 1952), the effective atomic number of a
material composed of several elements cannot be expressed by
a single number, it can be concluded that it is an energy
dependent parameter due to the different partial photon
interaction processes with matter for which the various atomic
numbers in the material have to be weighted differently. From the
results, it can be concluded that the effective atomic numbers of
TSW, Portland cement, pointing and lime vary with photon
energy. The effective atomic numbers were found to decrease
with increasing photon energy for TSW, Portland cement, pointing
and lime material.
It has been observed that the variation in Z
eff
depends also on
the range of atomic numbers of elements of which the TSW and
building materials are composed besides the relative proportion.
For a particular value of the incident photon energy, the Z
eff
glu, R.,
_
Ic-elli, O., Erzeneo