Вы находитесь на странице: 1из 36

Cooper Bussmann

High Speed Fuses - IEC standard

Alw

en

Al

n!

nglig - Alltid
pp
tillg
e
ltid
www.chscontrols.se

ay
op
s av
ailable - Always

Cooper Bussmann
High Speed Fuses - IEC standard
Contents
Cylindrical fuses, 6x32 mm....................................................................... 2
Cylindrical fuses, 10x38 mm..................................................................... 2
Cylindrical fuses, 14x51 mm..................................................................... 3
Cylindrical fuses, 22x58 mm..................................................................... 5
Square body solid contact blade fuses ..................................................... 5

Neozed and Diazed fuses ........................................................................ 28


Micro switches and trip indicators............................................................. 30
Fuse disconnectors for cylindrical fuses ................................................... 31
Fuseholders for square body solid blade fuses ........................................ 32
Fuseholders for square body fuses, DIN 80/DIN 110 slotted blade.......... 33

Square body fuses with DIN 80 slotted L-contact blade ........................... 9


Square body fuses with DIN 80/110 slotted contact blade ....................... 11
Square body fuses with flush-end contact ................................................ 17
BS 88 cylindrical fuses with contact blade................................................ 24
BS 88 square body fuses with contact blade............................................ 27

Application guide, high speed fuses ......................................................... 34


Installation guidance ................................................................................. 36

The catalogue contains only the most common types, contact


CHS Controls for other Cooper Bussmann fuses!

6x32 mm cylindrical fuses 500 V class aR


Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standard

Ceramic body, tin plated ferrules of copper/copper alloy


500 VAC, 0,5-5A 500 VDC
aR
50 kA, 25-30 A: 20 kA
IEC 60269-4

Certificate, approvals

CE, UR file E91958, CSA 1-7 A file 053787-C-000

Catalogue numbers - 6x32 mm cylindrical fuses, 500 V class aR


Rated
current I2t Pre-arc
In, A
1 ms, A2s

I2t Total
500 V, A2s

Power loss
W at In

Catalogue number
fuse without indicator

Weight Packing
each, g size

0,25
0,5
1
2
3,15

0,01
0,05
0,4
1,3
3,1

0,05
0,25
2
3,5
7,7

2,7
1,2
1,7
3,2
2,9

CBFWH-250A6F
CBFWH-500A6F
CBFWH-001A6F
CBFWH-002A6F
CBFWH-3-15A6F

3
3
3
3
3

10
10
10
10
10

5
6,3
7
10
12,5

15
36
50
9,9
20

40
90
125
139
60

2,1
2,3
2,5
2,86
3,53

CBFWH-005A6F
CBFWH-6-30A6F
CBFWH-007A6F
CBFWH-010A6F
CBFWH-012-5A6F

3
3
3
3
3

10
10
5
5
5

15
16
20
25
30

44
48
75
126
145

146
177
259
345
430

3,08
4,48
4,26

CBFWH-015A6F
CBFWH-016A6F
CBFWH-020A6F
CBFWH-025A6F
CBFWH-030A6F

3
3
3
3
3

5
5
5
5
5

10x38 mm cylindrical fuses, 600-700 V class aR


Technical data

Material
Rated voltage, Un
Utilization class
Rated breaking capacity

Ceramic body, tin plated ferrules of copper/copper alloy


1-4 A: 700 VAC/VDC, 6-25 A: 600 VAC/VDC, 32A: 600 VAC
aR
1-4 A: 200 kA vid 700 VAC, 50 kA at 700 VDC
6-25 A: 200 kA vid 600 VAC, 50 kA at 600 VDC
32 A: 200 kA at 600 VAC

Standard
Certificate, approvals

IEC 60269-4
CE, UR file E91958, CSA file 053787-C-000

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Catalogue numbers - 10x38 mm cylindrical fuses, 600-700 V class aR see note 1
Rated
current I2t Pre-arc
In, A
1 ms, A2s

I2t Total
600 V, A2s

Power
loss
W at In

Max RMS current


for installation Catalogue number
in fuse disconn. fuse without indicator

Weight Packing
each, g size

1
2
3
4
6

0,2
0,5
1,6
5,2
4

1,2
3
11
32
30

0,5
1,2
1,5
1,5
1,5

1
2
3
4
6

CBFWC-1A10F
CBFWC-2A10F
CBFWC-3A10F
CBFWC-4A10F
CBFWC-6A10F

9
9
9
9
9

10
10
10
10
10

8
10
12
16
20

6
9
15
25
34

50
70
120
150
260

2
2,5
3
3,5
4,8

8
10
12
15
16

CBFWC-8A10F
CBFWC-10A10F
CBFWC-12A10F
CBFWC-16A10F
CBFWC-20A10F

9
9
9
9
9

10
10
10
10
10

25
32

60
95

390
600

6
7,5

19
21

CBFWC-25A10F
CBFWC-32A10F

9
9

10
10

10x38 mm cylindrical fuses, 900-1000 VDC class gPV


Technical data
Material

Ceramic body, tin plated ferrules of copper/copper alloy


Ceramic body, tin plated L-contact blade for screw mounting
1000 VDC
gPV

Rated voltage, Un
Utilization class
Rated breaking capacity

Minimum interrupting rating


Standard

1-6 A: 40 kA, L/R < 1 ms, UL 10 kA


8-15 A: 33 kA, L/R < 1 ms, UL 10 kA
20 A: 10 kA, L/R < 1 ms
1,3 x In
IEC 60269-6, 1-15 A UL 2579

Certificate, approval

CE, RoHS, UL file E335324

Catalogue numbers - 10x38 mm cylindrical fuses, 900-1000 VDC class gR see note 1, 2
Rated
current I2t Pre-arc
In, A
1 ms, A2s

I2t Total
Un, A2s

Power
loss
W at In

Max RMS curr. Catalogue number


for installation Cylindrical fuse
in fuse disconn. without indicator

Cylindrical fuse
with L-blade

Weight Packing
each, g size

1
2
3
4
5

0,15
1,2
4
9,5
19

0,4
3,4
11
26
50

1,5
1
1,3
1,3
1,6

1
2
3
4
5

CBPV-1A10F
CBPV-2A10F
CBPV-3A10F
CBPV-4A10F
CBPV-5A10F

CBPV-1A10F-T
CBPV-2A10F-T
CBPV-3A10F-T
CBPV-4A10F-T
CBPV-5A10F-T

11
11
11
11
11

10
10
10
10
10

6
8
10
12
15

30
3
7
12
22

90
32
70
120
220

1,8
2,1
2,3
2,7
2,9

6
8
10
12
15

CBPV-6A10F
CBPV-8A10F
CBPV-10A10F
CBPV-12A10F
CBPV-15A10F

CBPV-6A10F-T
CBPV-8A10F-T
CBPV-10A10F-T
CBPV-12A10F-T
CBPV-15A10F-T

11
11
11
11
11

10
10
10
10
10

20

34

240

3,5

16

CBPV-20A10F

CBPV-20A10F-T

11

10

Notes
1 Max RMS current applies for installation in Cooper Bussmann CH/CHM 1-3 pole fuse disconnectors at 20C ambient temperature. Values given are for guidance only,
always check that the fuse power losses do not exceed the power loss capacity for each fuse disconnector. Contact CHS Controls for correction factors for high ambient
temperature and multi-pole installations.
2 Contact CHS Controls for versions for PCB mounting.

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
14x51 and 22x58 mm cylindrical fuses, 690 V class aR
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standard

Ceramic body, tin plated ferrules of copper/copper alloy


IEC: 690 VAC, UL: 700 VAC, 100 A: IEC 600 VAC, UL 700 VAC
aR
200/50 kA vid 700 VAC/VDC
IEC 60269-4

Certificate, approvals

CE, UR file E91958, CSA file 053787-C-000, fuses without striker indicator

Catalogue numbers - 14x51 mm cylindrical fuses, 690 V class aR see note 1, 3


Rated
current I2t Pre-arc
In, A
1 ms, A2s

I2t Total
Un, A2s

Power
loss
W at In

Max RMS curr. Catalogue numbers


for installation in Fuse without
fuse disconn.
indicator

Fuse with
striker indicator

Weight Packing
each, g size

1
2
3
4
5

0,035
0,08
0,11
0,1
1,6

0,41
0,11
0,26
0,23
11

5,7
8,7
2,8
3
1,5

0,9
1,6
3
4
5

CBFWP-1A14F
CBFWP-2A14F
CBFWP-3A14F
CBFWP-4A14F
CBFWP-5A14F

CBFWP-1A14FI
CBFWP-2A14FI
CBFWP-3A14FI
CBFWP-4A14FI
CBFWP-5A14FI

25
25
25
25
25

10
10
10
10
10

10
15
20
25
30

3,6
8,6
26
46,5
58

38,5
70
230
375
485

4
5,5
6
7
9

10
14
18
21
22

CBFWP-10A14F
CBFWP-15A14F
CBFWP-20A14F
CBFWP-25A14F
CBFWP-30A14F

CBFWP-10A14FI
CBFWP-15A14FI
CBFWP-20A14FI
CBFWP-25A14FI
CBFWP-30A14FI

25
25
25
25
25

10
10
10
10
10

32
40
50

68
84
200

600
750
1800

7,6
8
9

27
32
38

CBFWP-32A14F
CBFWP-40A14F
CBFWP-50A14F

CBFWP-32A14FI
CBFWP-40A14FI
CBFWP-50A14FI

25
25
25

10
10
10

Catalogue numbers - 22x58 mm cylindrical fuses, 690 V class aR see note 1, 3


20
25
32
40
50

19
34
53,5
68
135

260
410
605
750
1600

5
6
8
9
9,5

20
25
32
40
50

CBFWP-20A22F
CBFWP-25A22F
CBFWP-32A22F
CBFWP-40A22F
CBFWP-50A22F

CBFWP-20A22FI
CBFWP-25A22FI
CBFWP-32A22FI
CBFWP-40A22FI
CBFWP-50A22FI

45
45
45
45
45

10
10
10
10
10

63
80
100

280
600
1100

3080
6600
12500

11
13,5
16

58
66
78

CBFWP-63A22F
CBFWP-80A22F
CBFWP-100A22F

CBFWP-63A22FI
CBFWP-80A22FI
CBFWP-100A22FI

45
45
45

10
10
10

Dimensions - Cylindrical fuses, mm

6,4

31,8
6x32 mm

10,3

38,1

11

58

10x38 mm

14,3

22,2
51
14x51 mm

58

22x58 mm

50
10x38 mm with
L-blade

Notes
1 Max RMS current applies for installation in Cooper Bussmann CH/CHM 1-3 pole fuse disconnectors at 20C ambient temperature. Values given are for guidance only,
always check that the fuse power losses do not exceed the power loss capacity for each fuse disconnector. Contact CHS Controls for correction factors for high ambient
temperature and multi-pole installations.
3 Fuse with striker kan be used in fuse disconnectors equipped with micro switch for remote fuse trip indication.

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Square body solid contact blade fuses 690 V class, aR/gR, size 000-00, 1-3
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standards

Ceramic body, silver plated contact blades of copper alloy


690 VAC
aR/gR
200 kA
IEC 60269-4, DIN 43620

Certificate, approvals

CE, UR file E125085, CSA file 053787-C-000, RoHS

Catalogue numbers - Square body solid contact blade fuses, 690 V class aR/gR, size 000-00, 1 see note 4

Size

Rated
current
In, A

Utilization
class

I2t Pre-arc
1 ms, A2s

I2t Total
690 V, A2s

Power loss
W at In

Catalogue number
fuse with visual and
mechanical indicator

Weight
each, g

Packing
size

000
000
000
000
000

10
16
20
25
32

gR
gR
gR
gR
gR

4
7
11,5
19
40

27
51
82,5
140
285

2,5
4
5
6
7

CB170M1558D
CB170M1559D
CB170M1560D
CB170M1561D
CB170M1562D

135
135
135
135
135

3
3
3
3
3

000
000
000
000
000

40
50
63
80
100

aR
gR
gR
aR
aR

65
115
215
380
695

490
815
1550
2700
4950

8,5
9,5
11,5
15
16,5

CB170M1563D
CB170M1564D
CB170M1565D
CB170M1566D
CB170M1567D

135
135
135
135
135

3
3
3
3
3

000
000
000
000
00

125
160
200
250
315

aR
aR
aR
aR
aR

1180
2300
4350
7900
12000

8250
16500
31000
56000
84500

21,5
25
29,5
35,5
45

CB170M1568D
CB170M1569D
CB170M1570D
CB170M1571D
CB170M1572D

135
135
135
135
200

3
3
3
3
3

1
1
1
1
1

40
50
63
80
100

aR
aR
aR
aR
aR

40
78
120
185
360

285
550
850
1350
2600

4
4,5
6,5
8,5
10

CB170M3808D
CB170M3809D
CB170M3810D
CB170M3811D
CB170M3812D

409
409
409
409
409

3
3
3
3
3

1
1
1
1
1

125
160
200
250
315

aR
aR
aR
aR
aR

550
1150
2300
4350
7300

3900
8250
16500
31000
52000

11
12
12,5
16
20

CB170M3813D
CB170M3814D
CB170M3815D
CB170M3816D
CB170M3817D

409
409
409
409
409

3
3
3
3
3

1
1
1
1
1

350
400
450
500
550

aR
aR
aR
aR
aR

10000
16000
21500
27000
33500

73000
115000
155000
190000
240000

21,5
23
26,5
28,5
33

CB170M3818D
CB170M3819D
CB170M4863D
CB170M4864D
CB170M4865D

409
409
409
409
409

3
3
3
3
3

1
1

630
700

aR
aR

48500
69500

345000
495000

37,5
39

CB170M4866D
CB170M4867D

409
409

3
3

Notes
4 The fuses have dual indication system, visual indication on the fuse body and mechanical indication located on the front of the fuse. The fuse can be equipped with a
microswitch for remote trip indication. The microswitch is mounted on one of the lifting lugs, se page 30.

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Catalogue numbers - Square body solid contact blade fuses, 690 V class aR, size 2-3 see note 4

Size

Rated
current
In, A

Utilization
class

I2t Pre-arc
1 ms, A2s

I2t Total
690 V, A2s

Power loss
W at In

Catalogue number
fuse with visual and
mechanical indicator

Weight
each, g

Packing
size

2
2
2
2
2

400
450
500
550
630

aR
aR
aR
aR
aR

11000
16000
21500
29000
41000

79000
115000
155000
215000
295000

29
32
34
36
42

CB170M5808D
CB170M5809D
CB170M5810D
CB170M5811D
CB170M5812D

647
647
647
647
647

3
3
3
3
3

2
2
2
2
2

700
800
900
1000
1100

aR
aR
aR
aR
aR

60500
86000
125000
180000
245000

430000
610000
895000
1300000
1750000

43
48
52
53
56

CB170M5813D
CB170M5814D
CB170M5815D
CB170M5816D
CB170M5817D

647
647
647
647
647

3
3
3
3
3

3
3
3
3
3

500
550
630
700
800

aR
aR
aR
aR
aR

14000
19500
31000
45000
69500

99500
140000
222000
320000
490000

43
44
45
46
48

CB170M6808D
CB170M6809D
CB170M6810D
CB170M6811D
CB170M6812D

1113
1113
1113
1113
1113

1
1
1
1
1

3
3
3
3
3

900
1000
1100
1250
1400

aR
aR
aR
aR
aR

100000
140000
190000
300000
380000

720000
985000
1400000
2150000
2700000

50
56
57
61
70

CB170M6813D
CB170M6814D
CB170M6892D
CB170M8554D
CB170M8555D

1113
1113
1113
1113
1113

1
1
1
1
1

3
3

1500
1600

aR
aR

470000
585000

3350000
4150000

72
74

CB170M8556D
CB170M8557D

1113
1113

1
1

Square body solid contact blade fuses, 690 V class gR, size 00, 1-3
Technical data
Material
Rated voltage, Un
Utilization class
Rated beakring capacity
Standards

Ceramic body, tin plated contact blades of copper/copper alloy


690 VAC
gR
200 kA
IEC 60269-4, DIN 43620

Certificate

CE

Catalogue numbers - Square body solid contact blade fuses, 690 V class gR, size 00 see note 5

Size

Rated
current
In, A

I2t Pre-arc
1 ms, A2s

I2t Total
690 V, A2s

Power loss
W at In

Catalogue number
Fuse with mechanical
indicator type T

Weight
each, g

Packing
size

00
00
00
00
00

10
16
20
25
32

3,8
7,2
13
24
53

20
38
70
125
275

3,5
5,5
6
8
9

CB170M2691
CB170M2692
CB170M2693
CB170M2694
CB170M2695

182
182
182
182
182

3
3
3
3
3

00
00
00
00
00

40
50
63
80
100

95
185
345
695
1250

490
1000
1800
3600
6650

10
11
14
16
19

CB170M2696
CB170M2697
CB170M2698
CB170M2699
CB170M2700

182
182
182
182
204

3
3
3
3
3

00
00

125
160

2300
4350

12000
22500

23
29

CB170M2701
CB170M2702

204
204

3
3

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Catalogue numbers - Square body solid contact blade fuses, 690 V class gR, size 1-3 see note 5

Size

Rated
current
In, A

I2t Pre-arc
1 ms, A2s

I2t Total
690 V, A2s

Power loss
W at In

Catalogue number
Fuse with mechanical
indicator type T

Weight
each, g

Packing
size

1
1
1
1
1

50
63
80
100
125

135
245
500
950
1850

705
1300
2600
4850
9500

12
15
17
20
23

CB170M4176
CB170M4177
CB170M4178
CB170M4179
CB170M4180

593
593
593
593
593

3
3
3
3
3

1
1
1
1
1

160
200
250
315
350

3450
6750
13500
26000
34000

18000
34500
70500
135000
175000

28
31
35
41
45

CB170M4181
CB170M4182
CB170M4183
CB170M4184
CB170M4185

593
593
593
593
593

3
3
3
3
3

1
2
2
2
2

400
200
250
315
350

48500
5650
10000
19500
26000

250000
29000
52500
105000
135000

48
33
40
46
50

CB170M4186
CB170M5881
CB170M5882
CB170M5883
CB170M5884

593
700
700
700
700

3
3
3
3
3

2
2
2
2
2

400
450
500
550
630

39500
55500
73000
100000
150000

205000
290000
375000
515000
770000

53
59
66
70
79

CB170M5885
CB170M5886
CB170M5887
CB170M5888
CB170M5889

700
700
700
700
700

3
3
3
3
3

3
3
3
3
3

350
400
450
500
550

23000
34000
48500
64000
84500

120000
175000
250000
330000
435000

55
59
62
67
70

CB170M6080
CB170M6081
CB170M6082
CB170M6083
CB170M6084

1115
1115
1115
1115
1115

1
1
1
1
1

3
3
3

630
700
800

125000
160000
245000

645000
840000
1300000

85
93
99

CB170M6085
CB170M6086
CB170M6087

1115
1115
1115

1
1
1

Notes
4 The fuses have dual indication system, visual indication on the fuse body and mechanical indication located on the front of the fuse. The fuse can be equipped with a
microswitch for remote trip indication. The microswitch is mounted on one of the lifting lugs, se page 30.
5 Fuse with mechanical indicator type T can be equipped with microswitch for remote trip indication. The microswitch is mounted on one of the lifting lugs, see page 30.

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Square body solid contact blade fuses, 900-1000 V class aR, size 00
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standards

Ceramic body, tin plated contact blades of copper/copper alloy


900-1000 VAC
aR
125 kA
IEC 60269-4, DIN 43620

Certificate, approvals

CE, UR fil E125085, CSA file 053787-C-000

Catalogue numbers - Square body solid contact blade fuses 900-1000 V class gR, size 00 see note 5

Size

Rated
current
In, A

I2t Pre-arc
1 ms, A2s

I2t Total
690 V, A2s

Power loss
W at In

Catalogue number
Fuse with mechanical
indicator type T

Weight
each, g

Packing
size

00
00
00
00
00

20
25
32
35
40

1000
1000
1000
1000
1000

15
28,5
53
69
105

110
210
390
500
760

8,5
9,5
11
12
13

CB170M2673
CB170M2674
CB170M2675
CB170M2676
CB170M2677

200
200
200
200
200

6
6
6
6
6

00
00
00
00
00

50
63
80
100
125

1000
1000
1000
1000
1000

215
380
815
1550
3000

1550
2750
5900
11500
22000

14
16
18
21
23

CB170M2678
CB170M2679
CB170M2680
CB170M2681
CB170M2682

200
200
200
200
200

6
6
6
6
6

00
00
00

160
200
225

1000
900
900

6250
12000
18000

45000
86500
115000

26
31
33

CB170M2683
CB170M2684
CB170M2685

200
200
200

6
6
6

Dimensions - Square body solid contact blade fuses, mm


Fuse size

D
A

Square body solid contact blade fuses class aR


Size 000
78,5
20,5
52
Size 00
78,5
30
59
Size 00, 1000 V
78,5
30
60
Size1
135
40
64
Size 2
150
54
72

53
53
49
71,4
71,4

Size 3

72,4

150

71

87

Square body solid contact blade fuses class gR


Size 000
78,5
20,5
52
Size 00
78,5
30
60
Size1
135
52
66
Size 2
150
60
74
Size 3
150
75
89

53
49
68
68
68

Notes
5 Fuse with mechanical indicator type T can be equipped with microswitch for remote trip indication. The microswitch is mounted on one of the lifting lugs, see page 30.

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Square body fuses with DIN80 slotted L-contact blade, 690 V class aR/gR, size 0000-00
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standards

Ceramic body, tin plated slotted L-contact blade of copper/copper alloy


IEC: 690, UL: 700 VAC
aR/gR
200 kA
IEC 60269-4, DIN 43653

Certificate, approvals

CE, size 000 UR file E125085, CSA file 053787-C-000, CCC

Catalogue No. - Square body fuses, DIN80 slotted L-contact blade, 690 V class aR/gR, size 0000-00 see note 5

Size

Rated
current Utilization I2t Pre-arc
In, A
class
1 ms, A2s

I2t Total
660 V, A2s

Power
loss
W at In

Catalogue number - fuse


without
with visual
indicator
indicator

0000
0000
0000
0000
0000

10
16
20
25
32

gR
gR
gR
gR
gR

3,8
8,5
15
23,5
43

25,5
56
105
160
290

3,5
4,5
5
8
9

CB170M0108
CB170M0109
CB170M0110
CB170M0111
CB170M0112

CB170M0158
CB170M0159
CB170M0160
CB170M0161
CB170M0162

90
90
90
90
90

10
10
10
10
10

0000
0000
0000
0000
0000

40
50
63
80
100

gR
aR
aR
aR
aR

77
135
260
485
860

515
915
1750
3250
5700

11
12
13
17
18

CB170M0113
CB170M0114
CB170M0115
CB170M0116
CB170M0117

CB170M0163
CB170M0164
CB170M0165
CB170M0166
CB170M0167

90
90
90
90
90

10
10
10
10
10

000
000
000
000
000

10
16
20
25
32

gR
gR
gR
gR
gR

3,8
7,2
11,5
19
40

25,5
48
78
130
270

3
5,5
7
9
10

CB170M1308
CB170M1309
CB170M1310
CB170M1311
CB170M1312

CB170M1358
CB170M1359
CB170M1360
CB170M1361
CB170M1362

CB170M1408
CB170M1409
CB170M1410
CB170M1411
CB170M1412

135
135
135
135
135

3
3
3
3
3

000
000
000
000
000

40
50
63
80
100

gR
gR
gR
aR
aR

69
115
215
380
695

460
770
1450
2550
4650

12
15
16
19
24

CB170M1313
CB170M1314
CB170M1315
CB170M1316
CB170M1317

CB170M1363
CB170M1364
CB170M1365
CB170M1366
CB170M1367

CB170M1413
CB170M1414
CB170M1415
CB170M1416
CB170M1417

135
135
135
135
135

3
3
3
3
3

000
000
000
000
000

125
160
200
250
315

aR
aR
aR
aR
aR

1200
2300
4200
7750
12000

8500
16000
28000
51500
80500

28
32
37
42
52

CB170M1318
CB170M1319
CB170M1320
CB170M1321
CB170M1322

CB170M1368
CB170M1369
CB170M1370
CB170M1371
CB170M1372

CB170M1418
CB170M1419
CB170M1420
CB170M1421
CB170M1422

135
135
135
135
135

3
3
3
3
3

00
00
00
00
00

25
32
40
50
63

gR
gR
gR
gR
gR

19
28,5
50
95
170

130
195
360
640
1200

6
7
9
10
12

CB170M2608
CB170M2609
CB170M2610
CB170M2611
CB170M2612

CB170M2658
CB170M2659
CB170M2660
CB170M2661
CB170M2662

215
215
215
215
215

3
3
3
3
3

00
00
00
00
00

80
100
125
160
200

gR
aR
aR
aR
aR

310
620
1000
1900
3400

2100
4150
6950
13000
23000

15
20
25
30
35

CB170M2613
CB170M2614
CB170M2615
CB170M2616
CB170M2617

CB170M2663
CB170M2664
CB170M2665
CB170M2666
CB170M2667

215
215
215
215
215

3
3
3
3
3

00
00
00
00

250
315
350
400

aR
aR
aR
aR

6250
10000
13500
18000

42000
68500
91500
125000

45
55
60
70

CB170M2618
CB170M2619
CB170M2620
CB170M2621

CB170M2668
CB170M2669
CB170M2670
CB170M2671

215
215
215
215

3
3
3
3

www.chscontrols.se

with mechanical Weight Packing


indicator type T each, g size

Cooper Bussmann
High Speed Fuses - IEC standard
Square body fuses with DIN80 slotted L-contact blade, 900-1000 V class aR, size 00
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standards

Ceramic body, tin plated slotted L-contact blade of copper/copper alloy


900-1000 VAC
aR
125 kA
IEC 60269-4, DIN 43653

Certificate, approvals

CE, 20-250 A UR file E125085, CSA file 053787-C-000

Catalogue numbers - Square body fuses, DIN80 slotted L-contact blade, 900-1000 V class aR, size 00 see note 5

Size

Rated Rated
current voltage
In, A
Un, V

I2t Pre-arc
1 ms, A2s

I2t Total
Un V, A2s

Power
loss
W at In

Catalogue number - fuse


with visual
with mechanical Weight Packing
indicator
indicator type T each, g size

00
00
00
00
00

20
25
32
35
40

1000
1000
1000
1000
1000

20
30
55
69
100

140
210
390
500
690

5
7
9
10
11

CB170M4802
CB170M4803
CB170M4804
CB170M4805
CB170M4806

CB170M4822
CB170M4823
CB170M4824
CB170M4825
CB170M4826

215
215
215
215
215

6
6
6
6
6

00
00
00
00
00

50
63
80
100
125

1000
1000
1000
1000
1000

170
280
500
950
1500

1200
2000
3500
6850
11500

13
18
22
25
33

CB170M4807
CB170M4808
CB170M4809
CB170M4810
CB170M4811

CB170M4827
CB170M4828
CB170M4829
CB170M4830
CB170M4831

215
215
215
215
215

6
6
6
6
6

00
00
00
00

160
200
250
315

1000
1000
1000
900

3000
5600
10000
18000

22000
40500
74000
115000

37
40
48
58

CB170M4812
CB170M4813
CB170M4814
CB170M4815

CB170M4832
CB170M4833
CB170M4834
CB170M4835

215
215
215
215

6
6
6
6

Dimensioner - Square body fuses with DIN80 slotted L-contact blade, mm


54
54
54
40

51

51

57

19
100

18

100

21

100

78

78

78

Size 0000

Size 000

Size 00

30

Notes
5 Fuse with mechanical indicator type T can be equipped with microswitch for remote trip indication. The microswitch is mounted on one of the lifting lugs, see page 30.
6 Fuse with mechanical indicator can be equipped with microswitch for remote trip indication. For fuses with mechanical indication type T, the microswitch is mounted on one
of the lifting lugs, for fuses with mechanical indication type K, the microswitch is mounted on the side of the fuse, se page 30.

10

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Square body fuses with DIN80/DIN110 slotted contact blade, 550-690 V class aR, size 1*-3
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standards

Ceramic body, tin plated slotted contact blade of copper/copper alloy


IEC: 550-690 VAC, UL: 550-700 VAC
aR
200 kA
IEC 60269-4, DIN 43653

Certificate, approvals

CE, UR file E125085, CSA file 053787-C-000, CCC

Catalogue numbers - Square body fuses, DIN80 slotted contact blade, 550-690 V class aR, size 1*-2 see note 6

Size

Rated Rated
current voltage
In, A IEC, Un, V

I2t Pre-arc
1 ms, A2s

I2t Total
660/Un V, A2s

Power
loss
W at In

Catalogue number - DIN80 slotted contact blade


visual
mechanical
mechanical
Weight Packing
indicator
indicator type T indicator type K each, g size

1*
1*
1*
1*
1*

40
50
63
80
100

690
690
690
690
690

40
77
115
185
360

270
515
770
1250
2450

9
11
14
18
21

CB170M3008
CB170M3009
CB170M3010
CB170M3011
CB170M3012

CB170M3058
CB170M3059
CB170M3060
CB170M3061
CB170M3062

CB170M3108
CB170M3109
CB170M3110
CB170M3111
CB170M3112

275
275
275
275
275

3
3
3
3
3

1*
1*
1*
1*
1*

125
160
200
250
315

690
690
690
690
690

550
1100
2200
4200
7000

3700
7500
15000
28500
46500

26
30
35
40
50

CB170M3013
CB170M3014
CB170M3015
CB170M3016
CB170M3017

CB170M3063
CB170M3064
CB170M3065
CB170M3066
CB170M3067

CB170M3113
CB170M3114
CB170M3115
CB170M3116
CB170M3117

275
275
275
275
275

3
3
3
3
3

1*
1*
1*
1*
1*

350
400
450
500
550

690
690
690
690
690

10000
15000
21000
27000
34000

68500
105000
140000
180000
230000

55
60
65
70
75

CB170M3018
CB170M3019
CB170M3020
CB170M3021
CB170M3022

CB170M3068
CB170M3069
CB170M3070
CB170M3071
CB170M3072

CB170M3118
CB170M3119
CB170M3120
CB170M3121
CB170M3122

275
275
275
275
275

3
3
3
3
3

1*
1
1
1
1

630
200
250
315
350

690
690
690
690
690

48500
1650
3100
6200
8500

325000
11500
21000
42000
59000

80
45
55
58
60

CB170M3023
CB170M4008
CB170M4009
CB170M4010
CB170M4011

CB170M3073
CB170M4058
CB170M4059
CB170M4060
CB170M4061

CB170M3123
CB170M4108
CB170M4109
CB170M4110
CB170M4111

275
450
450
450
450

3
3
3
3
3

1
1
1
1
1

400
450
500
550
630

690
690
690
690
690

13500
17000
25000
34000
52000

91500
120000
170000
230000
350000

65
70
72
75
80

CB170M4012
CB170M4013
CB170M4014
CB170M4015
CB170M4016

CB170M4062
CB170M4063
CB170M4064
CB170M4065
CB170M4066

CB170M4112
CB170M4113
CB170M4114
CB170M4115
CB170M4116

450
450
450
450
450

3
3
3
3
3

1
1
1
2
2

700
800
900
400
450

690
690
550
690
690

69500
105000
155000
11000
15500

465000
725000
850000
74000
105000

85
95
100
65
70

CB170M4017
CB170M4018
CB170M4019
CB170M5008
CB170M5009

CB170M4067
CB170M4068
CB170M4069
CB170M5058
CB170M5059

CB170M4117
CB170M4118
CB170M4119
CB170M5108
CB170M5109

450
450
450
650
650

3
3
3
3
3

2
2
2
2
2

500
550
630
700
800

690
690
690
690
690

21500
28000
41000
60500
86000

145000
190000
275000
405000
575000

75
80
90
95
105

CB170M5010
CB170M5011
CB170M5012
CB170M5013
CB170M5014

CB170M5060
CB170M5061
CB170M5062
CB170M5063
CB170M5064

CB170M5110
CB170M5111
CB170M5112
CB170M5113
CB170M5114

650
650
650
650
650

3
3
3
3
3

2
2
2
2

900
1000
1100
1250

690
690
600
600

125000
180000
245000
365000

840000
1250000
1600000
2400000

110
115
120
130

CB170M5015
CB170M5016
CB170M5017
CB170M5018

CB170M5065
CB170M5066
CB170M5067
CB170M5068

CB170M5115
CB170M5116
CB170M5117
CB170M5118

650
650
650
650

3
3
3
3

www.chscontrols.se

11

Cooper Bussmann
High Speed Fuses - IEC standard
Catalogue numbers - Square body fuses, DIN80 slotted contact blade, 550-690 V class aR, size 3 see note 6

Size

Rated Rated
current voltage
In, A IEC, Un, V

I2t Pre-arc
1 ms, A2s

I2t Total
660/Un V, A2s

Power
loss
W at In

Catalogue number - DIN80 slotted contact blade


visual
mechanical
mechanical
Weight Packing
indicator
indicator type T indicator type K each, g size

3
3
3
3
3

500
550
630
700
800

690
690
690
690
690

14000
19500
31000
44500
69500

95000
135000
210000
300000
465000

95
100
105
110
115

CB170M6008
CB170M6009
CB170M6010
CB170M6011
CB170M6012

CB170M6058
CB170M6059
CB170M6060
CB170M6061
CB170M6062

CB170M6108
CB170M6109
CB170M6110
CB170M6111
CB170M6112

910
910
910
910
910

1
1
1
1
1

3
3
3
3
3

900
1000
1100
1250
1400

690
690
690
690
690

100000
140000
190000
290000
370000

670000
945000
1300000
1950000
2450000

120
125
130
140
155

CB170M6013
CB170M6014
CB170M6015
CB170M6016
CB170M6017

CB170M6063
CB170M6064
CB170M6065
CB170M6066
CB170M6067

CB170M6113
CB170M6114
CB170M6115
CB170M6116
CB170M6117

910
910
910
910
910

1
1
1
1
1

3
3
3
3

1500
1600
1800
2000

690
690
600
550

460000
580000
880000
1150000

3100000
3900000
5250000
6350000

160
160
165
175

CB170M6018
CB170M6019
CB170M6020
CB170M6021

CB170M6068
CB170M6069
CB170M6070
CB170M6071

CB170M6118
CB170M6119
CB170M6120
CB170M6121

910
910
910
910

1
1
1
1

Catalogue numbers - Square body fuses, DIN110 slotted contact blade, 550-690 V class aR, size 1*-1 see note 6

Size

Rated Rated
current voltage
In, A IEC, Un, V

I2t Pre-arc
1 ms, A2s

I2t Total
660/Un V, A2s

Power
loss
W at In

Catalogue number - DIN110 slotted contact blade


visual
mechanical
mechanical
Weight Packing
indicator
indicator type T indicator type K each, g size

1*
1*
1*
1*
1*

40
50
63
80
100

690
690
690
690
690

40
77
115
185
360

270
515
770
1250
2450

9
11
14
18
21

CB170M3158
CB170M3159
CB170M3160
CB170M3161
CB170M3162

CB170M3208
CB170M3209
CB170M3210
CB170M3211
CB170M3212

CB170M3258
CB170M3259
CB170M3260
CB170M3261
CB170M3262

310
310
310
310
310

3
3
3
3
3

1*
1*
1*
1*
1*

125
160
200
250
315

690
690
690
690
690

550
1100
2200
4200
7000

3700
7500
15000
28500
46500

26
30
35
40
50

CB170M3163
CB170M3164
CB170M3165
CB170M3166
CB170M3167

CB170M3213
CB170M3214
CB170M3215
CB170M3216
CB170M3217

CB170M3263
CB170M3264
CB170M3265
CB170M3266
CB170M3267

310
310
310
310
310

3
3
3
3
3

1*
1*
1*
1*
1*

350
400
450
500
550

690
690
690
690
690

10000
15000
21000
27000
34000

68500
105000
140000
180000
230000

55
60
65
70
75

CB170M3168
CB170M3169
CB170M3170
CB170M3171
CB170M3172

CB170M3218
CB170M3219
CB170M3220
CB170M3221
CB170M3222

CB170M3268
CB170M3269
CB170M3270
CB170M3271
CB170M3272

310
310
310
310
310

3
3
3
3
3

1*
1
1
1
1

630
200
250
315
350

690
690
690
690
690

48500
1650
3100
6200
8500

325000
11500
21000
42000
59000

80
45
55
58
60

CB170M3173
CB170M4158
CB170M4159
CB170M4160
CB170M4161

CB170M3223
CB170M4208
CB170M4209
CB170M4210
CB170M4211

CB170M3273
CB170M4258
CB170M4259
CB170M4260
CB170M4261

310
485
485
485
485

3
3
3
3
3

1
1
1
1
1

400
450
500
550
630

690
690
690
690
690

13500
17000
25000
34000
52000

91500
120000
170000
230000
350000

65
70
72
75
80

CB170M4162
CB170M4163
CB170M4164
CB170M4165
CB170M4166

CB170M4212
CB170M4213
CB170M4214
CB170M4215
CB170M4216

CB170M4262
CB170M4263
CB170M4264
CB170M4265
CB170M4266

485
485
485
485
485

3
3
3
3
3

1
1
1

700
800
900

690
690
550

69500
105000
155000

465000
725000
850000

85
95
100

CB170M4167
CB170M4168
CB170M4169

CB170M4217
CB170M4218
CB170M4219

CB170M4267
CB170M4268
CB170M4269

485
485
485

3
3
3

12

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Catalogue numbers - Square body fuses, DIN110 slotted contact blade, 550-690 V class aR, size 2-3 see note 6

Size

Rated Rated
current voltage
In, A IEC, Un, V

I2t Pre-arc
1 ms, A2s

I2t Total
660/Un V, A2s

Power
loss
W at In

Catalogue number - DIN110 slotted contact blade


visual
mechanical
mechanical
Weight Packing
indicator
indicator type T indicator type K each, g size

2
2
2
2
2

400
450
500
550
630

690
690
690
690
690

11000
15500
21500
28000
41000

74000
105000
145000
190000
275000

65
70
75
80
90

CB170M5158
CB170M5159
CB170M5160
CB170M5161
CB170M5162

CB170M5208
CB170M5209
CB170M5210
CB170M5211
CB170M5212

CB170M5258
CB170M5259
CB170M5260
CB170M5261
CB170M5262

685
685
685
685
685

3
3
3
3
3

2
2
2
2
2

700
800
900
1000
1100

690
690
690
690
600

60500
86000
125000
180000
245000

405000
575000
840000
1250000
1600000

95
105
110
115
120

CB170M5163
CB170M5164
CB170M5165
CB170M5166
CB170M5167

CB170M5213
CB170M5214
CB170M5215
CB170M5216
CB170M5217

CB170M5263
CB170M5264
CB170M5265
CB170M5266
CB170M5267

685
685
685
685
685

3
3
3
3
3

2
3
3
3
3

1250
500
550
630
700

600
690
690
690
690

365000
14000
19500
31000
44500

2400000
95000
135000
210000
300000

130
95
100
105
110

CB170M5168
CB170M6158
CB170M6159
CB170M6160
CB170M6161

CB170M5218
CB170M6208
CB170M6209
CB170M6210
CB170M6211

CB170M5268
CB170M6258
CB170M6259
CB170M6260
CB170M6261

685
945
945
945
945

3
1
1
1
1

3
3
3
3
3

800
900
1000
1100
1250

690
690
690
690
690

69500
100000
140000
190000
290000

465000
670000
945000
1300000
1950000

115
120
125
130
140

CB170M6162
CB170M6163
CB170M6164
CB170M6165
CB170M6166

CB170M6212
CB170M6213
CB170M6214
CB170M6215
CB170M6216

CB170M6262
CB170M6263
CB170M6264
CB170M6265
CB170M6266

945
945
945
945
945

1
1
1
1
1

3
3
3
3
3

1400
1500
1600
1800
2000

690
690
690
600
550

370000
460000
580000
880000
1150000

2450000
3100000
3900000
5250000
6350000

155
160
160
165
175

CB170M6167
CB170M6168
CB170M6169
CB170M6170
CB170M6171

CB170M6217
CB170M6218
CB170M6219
CB170M6220
CB170M6221

CB170M6267
CB170M6268
CB170M6269
CB170M6270
CB170M6271

945
945
945
945
945

1
1
1
1
1

Dimensions - Square body fuses with DIN80/110 slotted contact blade 550-690 V, mm see note 7
Fuse size
E

78
A
Visual indicator
Mechanical indicator type T
DIN 80 slotted contact blade

108
A
Visual indicator
Mechanical indicator type T
DIN 110 slotted contact blade

Mechanical indicator type K


DIN 80 slotted contact blade

108
A

Fuses with visual indicator


Size 1*
104/134
Size 1
108/138
Size 2
108/138
Size 3
109/139

45
53
61
76

45
53
61
76

50
50
50
51

78
A

Fuses with mechanical indicator type T


Size 1*
104/134 45
Size 1
108/138 53
Size 2
108/138 61
Size 3
109/139 76

45
53
61
76

58
66
75
90

50
50
50
51

Fuses with mechanical indicator type K


Size 1*
104/134 45
Size 1
108/138 53
Size 2
108/138 61
Size 3
109/139 76

45
53
61
76

59
69
77
92

50
50
50
51

Mechanical indicator type K


DIN 110 slotted contact blade

Notes
6 Fuse with mechanical indicator can be equipped with microswitch for remote trip indication. For fuses with mechanical indication type T, the microswitch is mounted on one
of the lifting lugs, for fuses with mechanical indication type K, the microswitch is mounted on the side of the fuse, se page 30.
7 Dimension A, first value applies for square body fuses with DIN 80 slotted blade, the second value applies for square body fuses with DIN 110 slotted blade.

www.chscontrols.se

13

Cooper Bussmann
High Speed Fuses - IEC standard
Square body fuses with DIN110 slotted contact blade, 900-1000 V class aR, size 1*-3
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standards

Ceramic body, tin plated slotted contact blade of copper/copper alloy


900-1000 VAC
aR
125 kA
IEC 60269-4, DIN 43653

Certificate, approvals

CE, size 2-3 UR file E125085, CSA file 053787-C-000

Catalogue numbers - Square body fuses, DIN110 slotted contact blade, 900-1000 V class aR, size 1*-3 see note 6

Size

Rated Rated
current voltage
In, A Un, V

I2t Pre-arc
1 ms, A2s

Power
I2t Total
loss
1000/Un V, A2s W at In

Cat. No. - DIN110 slotted blade


mechanical
mechanical
Weight Packing
indicator type T indicator type K each, g size

1*
1*
1*
1*
1*

50
63
80
100
125

1000
1000
1000
1000
1000

135
215
460
860
1450

815
1300
2750
5100
8600

20
25
30
35
40

CB170M3981
CB170M3982
CB170M3983
CB170M3984
CB170M3985

CB170M3965
CB170M3966
CB170M3967
CB170M3968
CB170M3969

465
465
465
465
465

3
3
3
3
3

1*
1*
1*
1*
1*

160
200
250
315
350

1000
1000
1000
1000
1000

2850
4950
9550
21500
29000

17500
29500
57000
130000
175000

45
48
50
60
65

CB170M3986
CB170M3987
CB170M3988
CB170M3989
CB170M3990

CB170M3970
CB170M3971
CB170M3972
CB170M3973
CB170M3974

465
465
465
465
465

3
3
3
3
3

1*
1
1
1
1

400
160
200
250
315

1000
1000
1000
1000
1000

42000
2200
4150
7750
16500

250000
13500
24500
46000
98500

70
40
45
52
60

CB170M3991
CB170M4980
CB170M4981
CB170M4982
CB170M4983

CB170M3975
CB170M4965
CB170M4966
CB170M4967
CB170M4968

465
670
670
670
670

3
3
3
3
3

1
1
1
1
1

350
400
450
500
550

1000
1000
1000
1000
1000

21500
31000
44500
63000
84500

130000
185000
265000
375000
500000

65
70
80
85
90

CB170M4984
CB170M4985
CB170M4986
CB170M4987
CB170M4988

CB170M4969
CB170M4970
CB170M4971
CB170M4972
CB170M4973

670
670
670
670
670

3
3
3
3
3

1
2
2
2
2

630
250
315
350
400

1000
1000
1000
1000
1000

125000
6750
13500
16500
26000

755000
40000
81500
99000
155000

98
65
75
80
85

CB170M4989
CB170M5981
CB170M5982
CB170M5983
CB170M5984

CB170M4974
CB170M5966
CB170M5967
CB170M5968
CB170M5969

670
800
800
800
800

3
3
3
3
3

2
2
2
2
2

450
500
550
630
700

1000
1000
1000
1000
1000

35500
49500
66000
93500
130000

210000
295000
390000
555000
770000

90
95
100
110
115

CB170M5985
CB170M5986
CB170M5987
CB170M5988
CB170M5989

CB170M5970
CB170M5971
CB170M5972
CB170M5973
CB170M5974

800
800
800
800
800

3
3
3
3
3

2
3
3
3
3

800
315
350
400
450

1000
1000
1000
1000
1000

195000
9200
13000
19000
27000

1200000
54500
77500
115000
160000

125
90
95
105
107

CB170M5990
CB170M8629
CB170M8630
CB170M8631
CB170M8632

CB170M5975
CB170M8614
CB170M8615
CB170M8616
CB170M8617

800
1300
1300
1300
1300

3
1
1
1
1

Notes
6 Fuse with mechanical indicator can be equipped with microswitch for remote trip indication. For fuses with mechanical indication type T, the microswitch is mounted on one
of the lifting lugs, for fuses with mechanical indication type K, the microswitch is mounted on the side of the fuse, se page 30.

14

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Catalogue numbers - Square body fuses, DIN110 slotted contact blade, 900-1000 V class aR, size 3 see note 6

Size

Rated Rated
current voltage
In, A Un, V

I2t Pre-arc
1 ms, A2s

Power
I2t Total
loss
1000/Un V, A2s W at In

Cat. No. - DIN110 slotted blade


mechanical
mechanical
Weight Packing
indicator type T indicator type K each, g size

3
3
3
3
3

500
550
630
700
800

1000
1000
1000
1000
1000

37500
52000
82500
115000
170000

225000
310000
490000
700000
1050000

110
115
120
125
135

CB170M8633
CB170M8634
CB170M8635
CB170M8636
CB170M8637

CB170M8618
CB170M8619
CB170M8620
CB170M8621
CB170M8622

1300
1300
1300
1300
1300

1
1
1
1
1

3
3
3
3
3

900
1000
1100
1250
1400

1000
1000
1000
1000
900

250000
340000
460000
575000
795000

1500000
2050000
2750000
3400000
4200000

145
150
155
175
185

CB170M8638
CB170M8639
CB170M8640
CB170M8641
CB170M8642

CB170M8623
CB170M8624
CB170M8625
CB170M8626
CB170M8627

1300
1300
1300
1300
1300

1
1
1
1
1

Square body fuses with DIN110 slotted contact blade, 1100-1250 V class aR, size 1*-3
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standards

Ceramic body, tin plated slotted contact blade of copper/copper alloy


IEC: 1100-1250 VAC, UL: 1100-1300 VAC
aR
100 kA
IEC 60269-4, DIN 43653

Certificate, approvals

CE, UR file E125085 - contact CHS Controls, CCC

Catalogue numbers - Square body fuses, DIN110 slotted contact blade, 1100-1250 V class aR, size 1*-1 see note 6

Size

Rated Rated
current voltage
In, A IEC, Un, V

I2t Pre-arc
1 ms, A2s

Power
I2t Total
loss
1250/Un V, A2s W at In

Catalogue number - DIN110 slotted contact blade


visual
mechanical
mechanical
Weight Packing
indicator
indicator type T indicator type K each, g size

1*
1*
1*
1*
1*

50
63
80
100
125

1250
1250
1250
1250
1250

135
215
420
750
1450

1100
1750
3350
5950
11500

15
20
25
30
35

CB170M3138
CB170M3139
CB170M3140
CB170M3141
CB170M3142

CB170M3188
CB170M3189
CB170M3190
CB170M3191
CB170M3192

CB170M3238
CB170M3239
CB170M3240
CB170M3241
CB170M3242

465
465
465
465
465

3
3
3
3
3

1*
1*
1*
1*
1*

160
200
250
315
350

1250
1250
1250
1250
1250

2600
5150
9200
18500
27000

21000
41000
73000
150000
220000

40
45
55
60
65

CB170M3143
CB170M3144
CB170M3145
CB170M3146
CB170M3147

CB170M3193
CB170M3194
CB170M3195
CB170M3196
CB170M3197

CB170M3243
CB170M3244
CB170M3245
CB170M3246
CB170M3247

465
465
465
465
465

3
3
3
3
3

1*
1
1
1
1

400
160
200
250
315

1250
1250
1250
1250
1250

53000
1900
3800
7750
15000

335000
15500
30000
61500
120000

70
45
50
60
65

CB170M3148
CB170M4138
CB170M4139
CB170M4140
CB170M4141

CB170M3198
CB170M4188
CB170M4189
CB170M4190
CB170M4191

CB170M3248
CB170M4238
CB170M4239
CB170M4240
CB170M4241

465
685
685
685
685

3
3
3
3
3

1
1
1
1
1
1

350
400
450
500
550
630

1250
1250
1250
1250
1250
1100

20000
29500
42000
69500
95000
130000

165000
235000
335000
435000
590000
750000

70
75
80
85
95
100

CB170M4142
CB170M4143
CB170M4144
CB170M4145
CB170M4146
CB170M4147

CB170M4192
CB170M4193
CB170M4194
CB170M4195
CB170M4196
CB170M4197

CB170M4242
CB170M4243
CB170M4244
CB170M4245
CB170M4246
CB170M4247

685
685
685
685
685
685

3
3
3
3
3
3

Notes
6 Fuse with mechanical indicator can be equipped with microswitch for remote trip indication. For fuses with mechanical indication type T, the microswitch is mounted on one
of the lifting lugs, for fuses with mechanical indication type K, the microswitch is mounted on the side of the fuse, se page 30.

www.chscontrols.se

15

Cooper Bussmann
High Speed Fuses - IEC standard
Catalogue numbers - Square body fuses, DIN110 slotted contact blade, 1100-1250 V class aR, size 2-3 see note 6

Size

Rated Rated
current voltage
In, A IEC, Un, V

I2t Pre-arc
1 ms, A2s

Power
I2t Total
loss
1250/Un V, A2s W at In

Catalogue number - DIN110 slotted contact blade


visual
mechanical
mechanical
Weight Packing
indicator
indicator type T indicator type K each, g size

2
2
2
2
2

250
280
315
350
400

1250
1250
1250
1250
1250

6500
9350
13000
16500
23000

51500
74500
105000
135000
180000

65
70
75
80
85

CB170M5138
CB170M5139
CB170M5140
CB170M5141
CB170M5142

CB170M5188
CB170M5189
CB170M5190
CB170M5191
CB170M5192

CB170M5238
CB170M5239
CB170M5240
CB170M5241
CB170M5242

800
800
800
800
800

3
3
3
3
3

2
2
2
2
2

450
500
550
630
700

1250
1250
1250
1250
1250

34000
48000
62000
115000
160000

270000
380000
495000
730000
1050000

90
95
100
110
115

CB170M5143
CB170M5144
CB170M5145
CB170M5146
CB170M5147

CB170M5193
CB170M5194
CB170M5195
CB170M5196
CB170M5197

CB170M5243
CB170M5244
CB170M5245
CB170M5246
CB170M5247

800
800
800
800
800

3
3
3
3
3

2
2
2
3
3

800
900
1000
315
350

1250
1100
1100
1250
1250

245000
360000
480000
9500
13500

1550000
2000000
2600000
77500
110000

120
125
135
85
90

CB170M5148
CB170M5149
CB170M5150
CB170M6138
CB170M6139

CB170M5198
CB170M5199
CB170M5200
CB170M6188
CB170M6189

CB170M5248
CB170M5249
CB170M5250
CB170M6238
CB170M6239

800
800
800
1300
1300

3
3
3
1
1

3
3
3
3
3

400
450
500
550
630

1250
1250
1250
1250
1250

19500
31000
39000
55000
83500

160000
245000
310000
435000
665000

95
100
105
110
115

CB170M6140
CB170M6141
CB170M6142
CB170M6143
CB170M6144

CB170M6190
CB170M6191
CB170M6192
CB170M6193
CB170M6194

CB170M6240
CB170M6241
CB170M6242
CB170M6243
CB170M6244

1300
1300
1300
1300
1300

1
1
1
1
1

3
3
3
3
3

700
800
900
1000
1100

1250
1250
1250
1250
1250

115000
205000
305000
450000
575000

940000
1300000
1900000
2750000
3600000

120
125
130
135
140

CB170M6145
CB170M6146
CB170M6147
CB170M6148
CB170M6149

CB170M6195
CB170M6196
CB170M6197
CB170M6198
CB170M6199

CB170M6245
CB170M6246
CB170M6247
CB170M6248
CB170M6249

1300
1300
1300
1300
1300

1
1
1
1
1

3
3

1250
1400

1100
1100

810000
1250000

4500000
6750000

145
150

CB170M6150
CB170M6151

CB170M6200
CB170M6201

CB170M6250
CB170M6251

1300
1300

1
1

Dimensions - Square body fuses with DIN110 slotted contact blade, 900-1250 V, mm
Fuse size
D

108
A

Visual and mechanical indicator type T

108
A
Mechanical indicator type K

B 1000 V

B 1250 V C max

Fuses with visual indicator


Size 1*
138
Size 1
138
Size 2
138
Size 3
139

43
51
59
74

Fuses with mechanical indicator type T


Size 1*
138
43
Size 1
138
51
Size 2
138
59
Size 3
139
74

45
53
61
76

61
69
75
90

80
80
80
81

Fuses with mechanical indicator type K


Size 1*
138
45
Size 1
138
53
Size 2
138
61
Size 3
139
76

45
53
61
76

61
69
77
92

80
80
80
81

80
80
80
81

Notes
6 Fuse with mechanical indicator can be equipped with microswitch for remote trip indication. For fuses with mechanical indication type T, the microswitch is mounted on one
of the lifting lugs, for fuses with mechanical indication type K, the microswitch is mounted on the side of the fuse, se page 30.

16

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Square body fuses with flush end contact, 550-690 V class aR, size 00, 1*-3
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standard

Ceramic body, tin plated flush-end contact of copper/copper alloy


IEC: 550-690 VAC, UL: 550-700 VAC
aR, size 00 25-80 A gR
200 kA
IEC 60269-4

Certificate, approvals

CE, UR file E125085, CSA file 053787-C-000, CCC - contact CHS Controls

Catalogue numbers - Square body fuses with flush end contact, 690 V class aR, size 00, 1* see note 6

Size

Rated Rated
current voltage
In, A IEC, Un, V

I2t Pre-arc
1 ms, A2s

I2t Total
660/Un V, A2s

Power
loss
W at In

Catalogue number - flush-end contact


visual
mechnical
mechanical
Weight Packing
indicator
indicator type T indicator type K each, g size

00
00
00
00
00

25
32
40
50
63

690
690
690
690
690

19
28,5
50
95
170

130
195
360
640
1200

6
7
9
10
12

CB170M2708
CB170M2709
CB170M2710
CB170M2711
CB170M2712

CB170M2758
CB170M2759
CB170M2760
CB170M2761
CB170M2762

195
195
195
195
195

5
5
5
5
5

00
00
00
00
00

80
100
125
160
200

690
690
690
690
690

310
620
1000
1900
3400

2100
4150
6950
13000
23000

15
20
25
30
35

CB170M2713
CB170M2714
CB170M2715
CB170M2716
CB170M2717

CB170M2763
CB170M2764
CB170M2765
CB170M2766
CB170M2767

195
195
195
195
195

5
5
5
5
5

00
00
00
00
1*

250
315
350
400
40

690
690
690
690
690

6250
10000
13500
18000
40

42000
68500
91500
125000
270

45
55
60
70
9

CB170M2718
CB170M2719
CB170M2720
CB170M2721
CB170M3408

CB170M2768
CB170M2769
CB170M2770
CB170M2771
CB170M3458

195
195
195
195
240

5
5
5
5
3

1*
1*
1*
1*
1*

50
63
80
100
125

690
690
690
690
690

77
115
185
360
550

515
770
1250
2450
3700

11
14
18
21
26

CB170M3409
CB170M3410
CB170M3411
CB170M3412
CB170M3413

CB170M3459
CB170M3460
CB170M3461
CB170M3462
CB170M3463

240
240
240
240
240

3
3
3
3
3

1*
1*
1*
1*
1*

160
200
250
315
350

690
690
690
690
690

1100
2200
4200
7000
10000

7500
15000
28500
46500
68500

30
35
40
50
55

CB170M3414
CB170M3415
CB170M3416
CB170M3417
CB170M3418

CB170M3464
CB170M3465
CB170M3466
CB170M3467
CB170M3468

240
240
240
240
240

3
3
3
3
3

1*
1*
1*
1*
1*

400
450
500
550
630

690
690
690
690
690

15000
21000
27000
34000
48500

105000
140000
180000
230000
325000

60
65
70
75
80

CB170M3419
CB170M3420
CB170M3421
CB170M3422
CB170M3423

CB170M3469
CB170M3470
CB170M3471
CB170M3472
CB170M3473

240
240
240
240
240

3
3
3
3
3

Notes
6 Fuse with mechanical indicator can be equipped with microswitch for remote trip indication. For fuses with mechanical indication type T, the microswitch is mounted on one
of the lifting lugs, for fuses with mechanical indication type K, the microswitch is mounted on the side of the fuse, se page 30.

www.chscontrols.se

17

Cooper Bussmann
High Speed Fuses - IEC standard
Catalogue numbers - Square body fuses with flush end contact, 690 V class aR, size 1-3 see note 6

Size

Rated Rated
current voltage
In, A IEC, Un, V

I2t Pre-arc
1 ms, A2s

I2t Total
660/Un V, A2s

Power
loss
W at In

Catalogue number - flush-end contact


visual
mechanical
Weight Packing
indicator
indicator type K each, g size

1
1
1
1
1

200
250
315
350
400

690
690
690
690
690

1650
3100
6200
8500
13500

11500
21000
42000
59000
91500

45
55
58
60
65

CB170M4408
CB170M4409
CB170M4410
CB170M4411
CB170M4412

CB170M4458
CB170M4459
CB170M4460
CB170M4461
CB170M4462

430
430
430
430
430

3
3
3
3
3

1
1
1
1
1

450
500
550
630
700

690
690
690
690
690

17000
25000
34000
52000
69500

120000
170000
230000
350000
465000

70
72
75
80
85

CB170M4413
CB170M4414
CB170M4415
CB170M4416
CB170M4417

CB170M4463
CB170M4464
CB170M4465
CB170M4466
CB170M4467

430
430
430
430
430

3
3
3
3
3

1
1
2
2
2

800
900
400
450
500

690
550
690
690
690

105000
155000
11000
15500
21500

725000
850000
74000
105000
145000

95
100
65
70
75

CB170M4418
CB170M4419
CB170M5408
CB170M5409
CB170M5410

CB170M4468
CB170M4469
CB170M5458
CB170M5459
CB170M5460

430
430
600
600
600

3
3
3
3
3

2
2
2
2
2

550
630
700
800
900

690
690
690
690
690

28000
41000
60500
86000
125000

190000
275000
405000
575000
840000

80
90
95
105
110

CB170M5411
CB170M5412
CB170M5413
CB170M5414
CB170M5415

CB170M5461
CB170M5462
CB170M5463
CB170M5464
CB170M5465

600
600
600
600
600

3
3
3
3
3

2
2
2
3
3

1000
1100
1250
500
550

690
600
600
690
690

180000
245000
365000
14000
19500

1250000
1600000
2400000
95000
135000

115
120
130
95
100

CB170M5416
CB170M5417
CB170M5418
CB170M6408
CB170M6409

CB170M5466
CB170M5467
CB170M5468
CB170M6458
CB170M6459

600
600
600
850
850

3
3
3
1
1

3
3
3
3
3

630
700
800
900
1000

690
690
690
690
690

31000
44500
69500
100000
140000

210000
300000
465000
670000
945000

105
110
115
120
125

CB170M6410
CB170M6411
CB170M6412
CB170M6413
CB170M6414

CB170M6460
CB170M6461
CB170M6462
CB170M6463
CB170M6464

850
850
850
850
850

1
1
1
1
1

3
3
3
3
3

1100
1250
1400
1500
1600

690
690
690
690
690

190000
290000
370000
460000
580000

1300000
1950000
2450000
3100000
3900000

130
140
155
160
160

CB170M6415
CB170M6416
CB170M6417
CB170M6418
CB170M6419

CB170M6465
CB170M6466
CB170M6467
CB170M6468
CB170M6469

850
850
850
850
850

1
1
1
1
1

3
3

1800
2000

600
550

880000
1150000

5250000
6350000

165
175

CB170M6420
CB170M6421

CB170M6470
CB170M6471

850
850

1
1

Dimensions - Square body fuses with flush end contact size 00, 1*-3, 550-690 V, mm see note 8, 9
Size 00
Visual indicator
Mechanical indicator type T

54

16

64
Size 1*-3
Visual indicator
Mechanical indicator type K

62

30

Size 1*
Size 1
Size 2
Size 3

51
51
51
53

45
53
61
76

45
53
61
76

59
69
77
92

50
50
50
51

17
20
24
30

18

48

M8

Fuse size A

www.chscontrols.se

M8
M8
M10
M12

Cooper Bussmann
High Speed Fuses - IEC standard
Square body fuses with flush end contacts, 900-1000 V class aR, size 1*-3
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standard

Ceramic body, tin plated flush-end contact of copper/copper alloy


900-1000 VAC
aR
125 kA
IEC 60269-4

Certificate

CE

Catalogue numbers - Square body fuses with flush end contact, 900-1000 V class aR, size 1*-2 see note 10

Size

Rated Rated
current voltage
In, A Un, V

I2t Pre-arc
1 ms, A2s

Power
I2t Total
loss
1000/Un V, A2s W at In

Catalogue number - flush-end contact


mechanical indicator type K
BKN75

Weight Packing
each, g size

1*
1*
1*
1*
1*

50
63
80
100
125

1000
1000
1000
1000
1000

135
215
460
860
1450

815
1300
2750
5100
8600

20
25
30
35
40

CB170M3951
CB170M3952
CB170M3953
CB170M3954
CB170M3955

395
395
395
395
395

3
3
3
3
3

1*
1*
1*
1*
1*

160
200
250
315
350

1000
1000
1000
1000
1000

2850
4950
9550
21500
29000

17500
29500
57000
130000
175000

45
48
50
60
65

CB170M3956
CB170M3957
CB170M3958
CB170M3959
CB170M3960

395
395
395
395
395

3
3
3
3
3

1*
1
1
1
1

400
160
200
250
315

1000
1000
1000
1000
1000

42000
2200
4150
7750
16500

250000
13500
24500
46000
98500

70
40
45
52
60

CB170M3961
CB170M4951
CB170M4952
CB170M4953
CB170M4954

395
630
630
630
630

3
3
3
3
3

1
1
1
1
1

350
400
450
500
550

1000
1000
1000
1000
1000

21500
31000
44500
63000
84500

130000
185000
265000
375000
500000

65
70
80
85
90

CB170M4955
CB170M4956
CB170M4957
CB170M4958
CB170M4959

630
630
630
630
630

3
3
3
3
3

1
2
2
2
2

630
250
315
350
400

1000
1000
1000
1000
1000

125000
6750
13500
16500
26000

755000
40000
81500
99000
155000

98
65
75
80
85

CB170M4960
CB170M5952
CB170M5953
CB170M5954
CB170M5955

630
750
750
750
750

3
3
3
3
3

2
2
2
2
2

450
500
550
630
700

1000
1000
1000
1000
1000

35500
49500
66000
93500
130000

210000
295000
390000
555000
770000

90
95
100
110
115

CB170M5956
CB170M5957
CB170M5958
CB170M5959
CB170M5960

750
750
750
750
750

3
3
3
3
3

800

1000

195000

1200000

125

CB170M5961

750

Notes
6 Fuse with mechanical indicator can be equipped with microswitch for remote trip indication. For fuses with mechanical indication type T, the microswitch is mounted on one
of the lifting lugs, for fuses with mechanical indication type K, the microswitch is mounted on the side of the fuse, se page 30.
8 Contact CHS Controls for versions with UNC-2B thread.
9 Fuses size 1*-3 with visual indication, the indicator is located at the front, external mechanical indication system (dimension D) does not apply.
10 Fuse with mechanical indicator type K can be equipped with microswitch for remote trip indication, the microswitch is mounted on the side of the fuse, se page 30.

www.chscontrols.se

19

Cooper Bussmann
High Speed Fuses - IEC standard
Catalogue numbers - Square body fuses with flush end contact, 900-1000 V class aR, size 3 see note 10

Size

Rated Rated
current voltage
In, A Un, V

I2t Pre-arc
1 ms, A2s

Power
I2t Total
loss
1000/Un V, A2s W at In

Catalogue number - flush-end contact


mechanical indicator type K
BKN75
BKN90

Weight Packing
each, g size

3
3
3
3
3

315
350
400
450
500

1000
1000
1000
1000
1000

9200
13000
19000
27000
37500

54500
77500
115000
160000
225000

90
95
105
107
110

CB170M8600
CB170M8601
CB170M8602
CB170M8603
CB170M8604

1190
1190
1190
1190
1190

1
1
1
1
1

3
3
3
3
3

550
630
700
800
900

1000
1000
1000
1000
1000

52000
82500
115000
170000
250000

310000
490000
700000
1050000
1500000

115
120
125
135
145

CB170M8605
CB170M8606
CB170M8607
CB170M8608
CB170M8609

1190
1190
1190
1190
1190

1
1
1
1
1

3
3
3
3

1000
1100
1250
1400

1000
1000
1000
900

340000
460000
575000
795000

2050000
2750000
3400000
4200000

150
155
175
185

CB170M8610
CB170M8611

1190
1190
1300
1300

1
1
1
1

CB170M8612
CB170M8613

Square body fuses with flush end contact, 1100-1250 V class aR, size 1*-3
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standard

Ceramic body, tin plated flush-end contact of copper/copper alloy


IEC: 1100-1250 VAC, UL: 1100-1300 VAC
aR
100 kA
IEC 60269-4

Certificate, approvals

CE, UR file E125085, CCC - contact CHS Controls

Catalogue numbers - Square body fuses with flush end contact, 1100-1250 V class aR, size 1* see note 10

Size

Rated Rated
current voltage
In, A Un, V

I2t Pre-arc
1 ms, A2s

Power
I2t Total
loss
1250/Un V, A2s W at In

Catalogue number - flush-end contact


mechanical indicator type K
BKN75
BKN80

Weight Packing
each, g size

1*
1*
1*
1*
1*

50
63
80
100
125

1250
1250
1250
1250
1250

135
215
420
750
1450

1100
1750
3350
5950
11500

15
20
25
30
35

CB170M3388
CB170M3389
CB170M3390
CB170M3391
CB170M3392

CB170M3438
CB170M3439
CB170M3440
CB170M3441
CB170M3442

395
395
395
395
395

3
3
3
3
3

1*
1*
1*
1*
1*

160
200
250
315
350

1250
1250
1250
1250
1250

2600
5150
9200
18500
27000

21000
41000
73000
150000
220000

40
45
55
60
65

CB170M3393
CB170M3394
CB170M3395
CB170M3396
CB170M3397

CB170M3443
CB170M3444
CB170M3445
CB170M3446
CB170M3447

395
395
395
395
395

3
3
3
3
3

1*

400

1250

53000

335000

70

CB170M3448

395

1
1
1
1
1

160
200
250
315
350

1250
1250
1250
1250
1250

1900
3800
7750
15000
20000

15500
30000
61500
120000
165000

45
50
60
65
70

CB170M4438
CB170M4439
CB170M4440
CB170M4441
CB170M4442

630
630
630
630
630

3
3
3
3
3

CB170M4388
CB170M4389
CB170M4390
CB170M4391
CB170M4392

Notes
10 Fuse with mechanical indicator type K can be equipped with microswitch for remote trip indication, the microswitch is mounted on the side of the fuse, se page 30.

20

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Catalogue numbers - Square body fuses with flush end contact, 1100-1250 V class aR, size 1-3 see note 10, 11

Size

Rated Rated
current voltage
In, A Un, V

I2t Pre-arc
1 ms, A2s

Power
I2t Total
loss
1250/Un V, A2s W at In

Catalogue number - flush-end contact


mechanical indicator type K
BKN75
BKN80
BKN90

Weight Packing
each, g size

1
1
1
1
1

400
450
500
550
630

1250
1250
1250
1250
1100

29500
42000
69500
95000
130000

235000
335000
435000
590000
750000

75
80
85
95
100

CB170M4393
CB170M4394
CB170M4395*)
CB170M4396**)
CB170M4397**)

CB170M4443
CB170M4444
CB170M4445
CB170M4446
CB170M4447

630
630
630
630
630

3
3
3
3
3

2
2
2
2
2

250
280
315
350
400

1250
1250
1250
1250
1250

6500
9350
13000
16500
23000

51500
74500
105000
135000
180000

65
70
75
80
85

CB170M5388
CB170M5389
CB170M5390
CB170M5391
CB170M5392

CB170M5438
CB170M5439
CB170M5440
CB170M5441
CB170M5442

750
750
750
750
750

3
3
3
3
3

2
2
2
2
2

450
500
550
630
700

1250
1250
1250
1250
1250

34000
48000
62000
115000
160000

270000
380000
495000
730000
1050000

90
95
100
110
115

CB170M5393
CB170M5394
CB170M5395
CB170M5396*)
CB170M5396**)

CB170M5443
CB170M5444
CB170M5445
CB170M5446
CB170M5447*)

750
750
750
750
750

3
3
3
3
3

2
2
2
3
3

800
900
1000
315
350

1250
1100
1100
1250
1250

245000
360000
480000
9500
13500

1550000
2000000
2600000
77500
110000

120
125
135
85
90

CB170M5396**) CB170M5448**)

CB170M6338
CB170M6339

CB170M6538
CB170M6539

750
750
750
1190
1190

3
3
3
1
1

3
3
3
3
3

400
450
500
550
630

1250
1250
1250
1250
1250

19500
31000
39000
55000
83500

160000
245000
310000
435000
665000

95
100
105
110
115

CB170M6340
CB170M6341
CB170M6342
CB170M6343
CB170M6344

CB170M6540
CB170M6541
CB170M6542
CB170M6543
CB170M6544

CB170M6494

1190
1190
1190
1190
1190

1
1
1
1
1

3
3
3
3
3

700
800
900
1000
1100

1250
1250
1250
1250
1250

115000
205000
305000
450000
575000

940000
1300000
1900000
2750000
3600000

120
125
130
135
140

CB170M6345
CB170M6346*)
CB170M6347*)
CB170M6348*)
CB170M6349*)

CB170M6545
CB170M6546
CB170M6547*)
CB170M6548*)
CB170M6549**)

CB170M6495
CB170M6496
CB170M6497
CB170M6498
CB170M6499

1190
1190
1190
1190
1190

1
1
1
1
1

3
3

1250
1400

1100
1100

810000
1250000

4500000
6750000

145
150

CB170M6500
CB170M6501

1190
1190

1
1

CB170M5494
CB170M5495
CB170M5496
CB170M5497
CB170M5498
CB170M5499
CB170M5500

Dimensioner - Square body fuses with flush end contact size 1*-3, 900-1250 V, mm see note 8, 10
D

Fuse size, type

A1000 V

A1250V B1000 V

B1250 V C max

Size 1*, BKN75


Size 1*, BKN80
Size 1, BKN/75
Size 1, BKN/80
Size 2, BKN/75

74

75
81
75
81
75

45
45
53
53
61

59
59
69
69
77

74
80
74
80
74

17
17
20
20
24

M8
M8
M8
M8
M10

61
61
76
76
76

77
77
92
92
92

80
80
74
80
80

24
24
30
30
30

M10
M10
M12
M12
M12

74
74

43
52
59

Size 2, BKN/80
Size 2, BKN/90
Size 3, BKN/75
Size 3, BKN 80
Size 3, BKN/90

75
91

81
91
76
83
91

74
74

Notes
8 Contact CHS Controls for versions with UNC-2B thread.
10 Fuse with mechanical indicator type K can be equipped with microswitch for remote trip indication, the microswitch is mounted on the side of the fuse, se page 30.
11 *) rated voltage 1100 V, **) rated voltage 1000 V.

www.chscontrols.se

21

Cooper Bussmann
High Speed Fuses - IEC standard
Square body fuses with flush end contact, 600-690 V class aR, size 4
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standard

Ceramic body, tin plated flush-end contact of copper/copper alloy


600-690 VAC
aR
200 kA
IEC 60269-4

Certificate

CE

Catalogue numbers - Square body fuses with flush end contact, 600-690 V class aR, size 4 see note 10

Size

Rated
current
In, A

Rated
voltage
Un, V

I2t Pre-arc
1 ms, A2s

I2t Total
660/Un V, A2s

Power
loss
W at In

catalogue number - flush- end contact


visual
mechanical
indicator
indicator type K

Weight
each, g

Packing
size

4
4
4
4
4

1000
1250
1400
1600
2000

690
690
690
690
690

76000
145000
205000
305000
600000

505000
965000
1400000
2050000
3950000

175
195
205
220
245

CB170M7058
CB170M7059
CB170M7060
CB170M7061
CB170M7062

CB170M7078
CB170M7079
CB170M7080
CB170M7081
CB170M7082

1975
1975
1975
1975
1975

1
1
1
1
1

4
4
4
4

2500
3000
3500
4000

690
690
690
600

1200000
2000000
3250000
4700000

7800000
13500000
22000000
28000000

275
305
325
355

CB170M7063
CB170M7064
CB170M7065
CB170M7066

CB170M7083
CB170M7084
CB170M7085
CB170M7086

1975
1975
1975
1975

1
1
1
1

Square body fuses with flush-end contact, 1000 V class aR, size 4
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standard

Ceramic body, tin plated flush-end contact of copper/copper alloy


1000 VAC
aR
125 kA
IEC 60269-4

Certificate

CE

Catalogue numbers - Square body fuses with flush end contact, 1000 V class aR, size 4 see note 10, 12

Size

Rated
current
In, A

Rated
voltage
Un, V

I2t Pre-arc
1 ms, A2s

I2t Total
Un V, A2s

Power
loss
W at In

4
4
4
4
4

1000
1100
1500
1700
1800

180000
250000
600000
850000
1000000

1100000
1500000
3600000
5000000
5950000

195
200
250
260
265

4
4
4
4
4

2000
2200
2500
2700
3000

1450000
2000000
3000000
3700000
4700000

8600000
12000000
18000000
22000000
28000000

270
280
295
310
380

catalogue number - flush- end contact


Mechanical indicator type K
BNK/95
SBNK/95

Weight
each, g

Packing
size

CB170M7636
CB170M7639
CB170M7661

CB170M7542
CB170M7031
CB170M7548
CB170M7034
CB170M7053

-/3200
-/3200
1975/3200
1975/3200
1975/3200

1
1
1
1
1

CB170M7963
CB170M7090
CB170M7640
CB170M7658
CB170M7962

CB170M7544
CB170M7035
CB170M7036
CB170M7037
CB170M7156

1975/3200
1975/3200
1975/3200
1975/3200
1975/3200

1
1
1
1
1

Notes
10 Fuse with mechanical indicator type K can be equipped with microswitch for remote trip indication, the microswitch is mounted on the side of the fuse, se page 30.
12 Weight, first value applies for type BKN/95, second value for type SBKN/95.

22

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Square body fuses with flush end contact, 1250 V class aR, size 4
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standard

Ceramic body, tin plated flush-end contact of copper/copper alloy


1250 VAC
aR
125 kA
IEC 60269-4

Certificate

CE

Catalogue numbers - Square body fuses with flush end contact, 1000 V class aR, size 4 see note 10, 12

Size

Rated
current
In, A

Rated
voltage
Un, V

I2t Pre-arc
1 ms, A2s

I2t Total
Un V, A2s

Power
loss
W at In

Catalogue number - flush- end contact


Mechanical indicator type K
BNK/105
SBNK/105

Weight
each, g

Packing
size

4
4
4
4
4

1400
1500
1700
1800
2000

800000
1000000
1400000
1700000
2300000

5000000
6200000
8700000
11000000
14500000

195
200
220
225
235

CB170M7217
CB170M7597
CB170M7676
CB170M7532
CB170M7633

CB170M7512
CB170M7510
CB170M7511
CB170M7976
CB170M7513

2200/3550
2200/3550
2200/3550
2200/3550
2200/3550

1
1
1
1
1

4
4
4

2200
2400
2500

3100000
4000000
4500000

19500000
25000000
28000000

245
255
260

CB170M7592
CB170M7107
CB170M7595

CB170M7546
CB170M7516
CB170M7978

2200/3550
2200/3550
2200/3550

1
1
1

Dimensions - Square body fuses with flush-end contact size 4, mm see note 8

56 105

4xM10

67
600-690 V, visual indicator

56 105

105

67
600-690 V, mechanical indicator type K

4xM10

56 105

4xM10

105
120

4xM10

56
133

95

3x11

105
120

1000 V, type BKN/95

95

105

1000 V type SBKN/95

4xM10

56 105

120

4xM10

56
133

106
1250 V type BKN105

3x11

105
120
106
1250 V type SBKN105

105
120

Notes
8 Contact CHS Controls for versions with UNC-2B thread.
10 Fuse with mechanical indicator type K can be equipped with microswitch for remote trip indication, the microswitch is mounted on the side of the fuse, se page 30.

www.chscontrols.se

23

Cooper Bussmann
High Speed Fuses - IEC standard
BS88 cylindrical fuses with contact blade, 240 V class aR
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standards

Ceramic body, tin plated contact blade of copper/copper alloy


240 VAC/150 VDC
aR
200/50 kA at 240 VAC/150VDC
IEC 60269-4, BS 88-4

Certificate, approvals

CE, UR contact CHS Controls for more information

Catalogue numbers - LCT BS88 cylindrical fuses size 8x28 mm with L-contact blade see note 13, 14
Rated current I2t Pre-arc
In, A
1 ms, A2s

I2t Total
120 VAC, A2s 240 VAC, A2s

Power loss
W at In

Catalogue number

Weight
each, g

Packing
size

6
10
12
16
20

6
12
22
50
80

1
2,5
2,5
2,5
4

CB6LCT
CB10LCT
CB12LCT
CB16LCT
CB20LCT

7
7
7
7
7

20
20
20
20
20

2
3,8
7
20
25

9
22
32
100
160

Catalogue numbers - LET BS88 cylindrical fuses size 7x26 mm with L-contact blade see note 13, 14, 15
25
32
35
50
63

18
32
50
100
180

120
200
320
500
1100

250
450
600
1400
2200

4
5
5
7
9

CB25LET
CB32LET
CB35LET
CB50LET
CB63LET

32
32
32
32
32

10
10
10
10
10

80
100
125
160
180

300
600
600
1100
1600

1900
3800
3800
7000
12000

3800
7500
7500
16000
29000

10
10
16
20
21

CB80LET
CB100LET
CB125LET
CB160LET
CB180LET

32
32
32
32
32

10
10
10
10
10

Catalogue numbers - LMT BS88 cylindrical fuses size 8x31 mm with L-contact blade see note 13, 14
160
200
250
315
355

1100
1500
3200
6000
8000

7000
10000
20000
35000
50000

16000
20000
40000
75000
100000

17
28
28
35
35

CB160LMT
CB200LMT
CB250LMT
CB315LMT
CB355LMT

185
185
185
185
185

1
1
1
1
1

400
450

14000
18000

70000
100000

160000
200000

40
42

CB400LMT
CB450LMT

185
185

1
1

Catalogue numbers - LMMT BS88 double cylindrical fuses size 38x31 mm with T-contact blade see note 13, 14
400
500
630
710
800

6000
14000
24000
32000
52000

35000
80000
150000
200000
300000

80000
170000
300000
460000
600000

60
64
75
77
82

CB400LMMT
CB500LMMT
CB630LMMT
CB710LMMT
CB800LMMT

360
360
360
360
360

1
1
1
1
1

900

75000

400000

800000

97

CB900LMMT

360

Notes
13 Contact CHS Controls for suitable fuseholders for BS 88 fuses.
14 BS 88 cylindrical fuses with contact blade > 20 A can be equipped with external trip indicator and microswitch for remote trip indication, see page 30.
15 Fuses type LET 7, 10, 12 and 16 A are also available but are not recommended for new applications.

24

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
BS 88 cylindrical fuses with contact blade, 690 V class aR
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standards

Ceramic body, tin plated contact blade of copper/copper alloy


690 VAC/500 VDC, type MT & MMT: 350 VDC
aR
200/50 kA vid 690 VAC/350-500 VDC
IEC 60269-4, BS 88-4

Certifikat, approvals

CE, UR contact CHS Controls fore more information

Catalogue numbers - CT BS88 cylindrical fuses size 9x55 mm with L-contact blade see note 13, 14
Rated current I2t Pre-arc
In, A
1 ms, A2s

I2t Total
120 VAC, A2s 240 VAC, A2s

Power loss
W at In

Catalogue number

Weight
each, g

Packing
size

6
10
12
16
20

8,5
30
40
66
150

2
3
3
7
7

CB6CT
CB10CT
CB12CT
CB16CT
CB20CT

10
10
10
10
10

20
20
20
20
20

1,8
7
10
16
32

12
48
65
110
220

Catalogue numbers - ET BS88 cylindrical fuses size 17x48 mm with L-contact blade see note 13, 14, 16
25
32
35
40
45

25
32
52
103
103

150
190
310
600
680

250
350
500
900
1100

7
11
11
9
11

CB25ET
CB32ET
CB35ET
CB40ET
CB45ET

41
41
41
41
41

10
10
10
10
10

56
63
80

135
171
360

950
1200
2500

1500
2000
4000

14
16
18

CB56ET
CB63ET
CB80ET

41
41
41

10
10
10

Catalogue numbers - FE BS88 cylindrical fuses size 38x31 mm with L-contact blade see note 13, 14
35
40
45
50
63

33
52
76
103
135

130
180
270
380
480

200
300
450
600
750

9
9
11
11
12

CB35FE
CB40FE
CB45FE
CB50FE
CB63FE

41
41
41
41
41

10
10
10
10
10

71
80
90
100

210
250
360
470

600
900
1300
1800

950
1500
2100
2800

17
20
20
23

CB71FE
CB80FE
CB90FE
CB100FE

41
41
41
41

10
10
10
10

Catalogue numbers - EET BS88 double cylindrical fuses size 17x46 mm with L-contact blade see note 13, 14, 16
90
110
140
160

490
600
1050
1500

3000
4000
7000
10000

4500
6500
12000
17000

19
27
35
39

CB90EET
CB110EET
CB140EET
CB160EET

91
91
91
91

5
5
5
5

Notes
13 Contact CHS Controls for suitable fuseholders for BS 88 fuses.
14 BS 88 cylindrical fuses with contact blade > 20 A can be equipped with external trip indicator and microswitch for remote trip indication, see page 30.
16 Fuses type ET 8, 12, 15 and 20 A as well as fuses type EET 65 and 75 A are also available but are not recommended for new applications.

www.chscontrols.se

25

Cooper Bussmann
High Speed Fuses - IEC standard
Catalogue numbers - FEE BS88 double cylindrical fuses size 17x46 mm with L-contact blade see note 13, 14
Rated current I2t Pre-arc
In, A
1 ms, A2s

I2t Total
120 VAC, A2s 240 VAC, A2s

Power loss
W at In

Catalogue number

Weight
each, g

Packing
size

100
120
140
160
180

400
540
850
1000
1400

1600
1900
2500
3700
5300

2400
3100
3800
5700
8400

24
32
36
46
46

CB100FEE
CB120FEE
CB140FEE
CB160FEE
CB180FEE

91
91
91
91
91

5
5
5
5
5

200

1900

7100

11400

52

CB200FEE

91

Catalogue numbers - FM BS88 cylindrical fuses size 38x50 mm with L-contact blade see note 13, 14
180
200
225
250
280

1400
2600
3700
5200
7000

7500
10500
14500
20500
30500

13500
18500
26500
37500
55000

40
40
44
48
48

CB180FM
CB200FM
CB225FM
CB250FM
CB280FM

230
230
230
230
230

1
1
1
1
1

315
350

10000
15000

40000
60000

77000
105000

55
55

CB315FM
CB350FM

230
230

1
1

Catalogue numbers - FMM BS 88 double cylindrical fuses size 38x50 mm with T-contact blade see note 13, 14
400
450
500
550
630

10000
15000
20000
30000
45000

40000
60000
82000
120000
180000

72500
105000
150000
215000
310000

85
90
100
100
100

CB400FMM
CB450FMM
CB500FMM
CB550FMM
CB630FMM

454
454
454
454
454

1
1
1
1
1

700

60000

240000

420000

120

CB700FMM

454

Catalogue numbers - MT BS88 cylindrical fuses size 38x50 mm with L-contact blade see note 13, 14
160
180
200
250
280

2400
3800
6000
11500
16500

15000
25000
40000
80000
100000

25000
38000
58000
110000
150000

26
26
27
32
35

CB160MT
CB180MT
CB200MT
CB250MT
CB280MT

230
230
230
230
230

1
1
1
1
1

315
355

19000
22000

125000
160000

180000
200000

42
51

CB315MT
CB355MT

230
230

1
1

Catalogue numbers - MMT BS88 double cylindrical fuses size 38x50 mm with T-contact blade see note 13, 14
180
200
225
280
315

1650
2200
3700
6600
8600

12000
16000
26000
47000
62000

18000
23000
40000
70000
91000

42
42
42
47
51

CB180MMT
CB200MMT
CB225MMT
CB280MMT
CB315MMT

454
454
454
454
454

1
1
1
1
1

355
400
450
500
560

13500
21000
30000
42000
60000

97000
150000
220000
300000
430000

140000
220000
320000
450000
640000

54
60
57
64
64

CB355MMT
CB400MMT
CB450MMT
CB500MMT
CB560MMT

454
454
454
454
454

1
1
1
1
1

630
710

68500
78000

500000
600000

720000
850000

86
105

CB630MMT
CB710MMT

454
454

1
1

Notes
13 Contact CHS Controls for suitable fuseholders for BS 88 fuses.
14 BS 88 cylindrical fuses with contact blade > 20 A can be equipped with external trip indicator and microswitch for remote trip indication, see page 30.

26

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
BS88 square body fuses with L-contact blade, 690 V class aR/gR, size 0000-000
Technical data
Material
Rated voltage, Un
Utilization class
Rated breaking capacity
Standards

Ceramic body, tin plated contact blade of copper/copper alloy


690 VAC
aR/gR
300 kA
IEC 60269-4, BS 88-4

Certificate

CE

Catalogue numbers - BS88 square body fuses with L-contact blade, 690 V class aR/gR, size 0000-000

Size

Rated
current Utilization I2t Pre-arc
In, A
class
1 ms, A2s

I2t Total
660 V, A2s

Power
loss
W at In

Catalogue number - fuse


without
with visual
indicator
indicator

Weight Packing
each, g size

0000
0000
0000
0000
0000

10
16
20
25
32

gR
gR
gR
gR
gR

3,8
8,5
15
23,5
43,5

25,5
56,5
105
160
290

3,5
4,5
5
8
9

CB170M0208
CB170M0209
CB170M0210
CB170M0211
CB170M0212

90
90
90
90
90

10
10
10
10
10

0000
0000
0000
0000
0000

40
50
63
80
100

gR
aR
aR
aR
aR

77,5
135
260
485
860

515
915
1750
3250
5700

11
12
13
17
18

CB170M0213
CB170M0214
CB170M0215
CB170M0216
CB170M0217

90
90
90
90
90

10
10
10
10
10

000
000
000
000
000

10
16
20
25
32

gR
gR
gR
gR
gR

3,8
7,2
11,5
19
40

25,5
48
78
130
270

3
5,5
7
9
10

CB170M1458
CB170M1459
CB170M1460
CB170M1461
CB170M1462

CB170M1508
CB170M1509
CB170M1510
CB170M1511
CB170M1512

135
135
135
135
135

5
5
5
5
5

000
000
000
000
000

40
50
63
80
100

gR
gR
gR
aR
aR

69
115
215
380
695

460
770
1450
2550
4650

12
15
16
19
24

CB170M1463
CB170M1464
CB170M1465
CB170M1466
CB170M1467

CB170M1513
CB170M1514
CB170M1515
CB170M1516
CB170M1517

135
135
135
135
135

5
5
5
5
5

000
000
000
000
000

125
160
200
250
315

aR
aR
aR
aR
aR

1200
2300
4200
7750
12000

8500
16000
28000
51500
80500

28
32
37
42
52

CB170M1468
CB170M1469
CB170M1470
CB170M1471
CB170M1472

CB170M1518
CB170M1519
CB170M1520
CB170M1521
CB170M1522

135
135
135
135
135

5
5
5
5
5

www.chscontrols.se

27

Cooper Bussmann
High Speed Fuses - IEC standard
Dimensions - BS88 fuses, mm
240 V cylindrical fuses with contact blade
9

41

19
47

83

56

84
18

38

38

42
Type LET

Type LCT

84

38

59
Type LMT
59
Type LMMT

690 V cylindrical fuses with contact blade


9
19
75

77

94

83
113
113

17

37

64

38
38

64

Type CT

41

19

Type ET/FE

70

FM: 80-85
MT 85

Type EET/FEE

Type FM/MT

FMM: 80-85
MMT: 85
Type FMM/MMT

690 V square body fuses with L-contact blade

23

19
78

95

65
70
Size 0000
Size 000

Neozed and Diazed fuses, 400 V class gR


Technical data
Material
Rated voltage, Un
Utility class
Rated breaking capacity
Standards

Ceramic body, tinned contacts


Neozed: 400 VAC, Diazed: 500 VAC
gR
50 kA
IEC 60269-4, VDE0636

Certificate

CE

Catalogue numbers - Neozed fuses 400 V class gR


Size

Rated current
In, A

I2t Pre-arc
1 ms, A2s

I2t Total
Un, A2s

Power loss
W at In

Catalogue number

Weight
each, g

Packing
size

D01
D01
D01
D01
D01

2
4
6
10
16

1
2
5
12
35

6,3
13
20
65
200

2,3
3,1
4
4,2
5,3

CB2NZ01R
CB4NZ01R
CB6NZ01R
CB10NZ01R
CB16NZ01R

6
6
6
6
6

10
10
10
10
10

D02
D02
D02
D02
D02

20
25
35
50
63

55
85
180
250
550

275
480
1000
1800
2500

8
9
10
15
17

CB20NZ02R
CB25NZ02R
CB35NZ02R
CB50NZ02R
CB63NZ02R

11
12
13
13
15

10
10
10
10
10

28

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Catalogue numbers - Diazed fuses 500 V class gR
Size

Rated current
In, A

I2t Pre-arc
1 ms, A2s

I2t Total
Un, A2s

Power loss
W at In

Catalogue number

Weight
each, g

Packing
size

DI
DI
DI
DI
DI

2
4
6
10
16

0,7
1,8
4
8
16,2

5,8
11
18
40
60

2,1
2,5
3,2
3,6
6,3

CB2D16R
CB4D16R
CB6D16R
CB10D16R
CB16D16R

12
12
12
13
14

20
20
20
20
20

DI
DI
D II
D II
D II

20
25
2
4
6

35,8
48,9
0,7
1,8
4

139
205
5,8
11
18

7,3
9
2,1
2,5
3,2

CB20D16R
CB25D16R
CB2D27R
CB4D27R
CB6D27R

15
16
27
27
27

20
20
5
5
5

D II
D II
D II
D II
D II

10
16
20
25
30

8
16,2
35,8
48,9
85

40
60
139
205
310

3,6
6,3
7,3
9
10

CB10D27R
CB16D27R
CB20D27R
CB25D27R
CB30D27R

27
28
29
30
30

5
5
5
5
5

D III
D III
D III
D IV
D IV

35
50
63
80
100

135
340
530
980
1950

539
1250
1890
4200
8450

12
19
23
33
51

CB35D33R
CB50D33R
CB63D33R
CB80D125R
CB100D125R

48
49
52
105
110

5
5
5
10
10

DV
DV
DV

125
160
200

3100
10000
17000

16000
24000
40000

60
71
90

CB125D200R
CB160D200R
CB200D200R

185
210
215

10
10
10

Dimensions - Neozed and Diazed fuses, mm


11

13

15

22

50
36
Neozed D01

33

27

58

56

50

50

46

36
Neozed D02

Diazed D I

Diazed D II

Diazed D III

Diazed D IV

Diazed D V

Terminal studs with inside hex for square body fuses with flush-end contact
Technical data
Material
Standards

Stainless steel type A2


DIN 913, ISO 4026

Catalogue numbers - Terminal stud with inside hex see note 17


Fuse

Terminal stud
size

Hex width, mm

Catalogue number

Weight
each, g

Packing
size

Size 00, 1*, 1


Size 2
Size 3
Size 4

M8x35, kit for1 fuse - 2 pcs


M10x40, kit for1 fuse - 2 pcs
M12x45, kit for1 fuse - 2 pcs
M10x40, kit for1 fuse - 8 pcs

4
5
6
5

CBSTUD2M835
CBSTUD2M1040
CBSTUD2M1245
CBSTUD8M1040

20
40
60
160

1
1
1
1

Notes
17 See page 36 for installation guidance and tightening torques.

www.chscontrols.se

29

Cooper Bussmann
High Speed Fuses - IEC standard
Microswitches for square body fuses
Technical data
Rated voltage, Un
Rated current
Contact
Terminals
Ingress protection, IEC 60529

250 VAC
2A
Changeover contact
2,8/6,3 mm quick connector
IP 00

Certificate

CE

Catalogue numbers - Microswitches for square body fuses

For installation on fuse type

Catalogue number
Microswitch with
2,8 mm quick conn.

Microswitch with
6,3 mm quick conn.

Weight Packing
each, g size

Solid blade fuses size 000-00, 1-3 with visual and mechanical indicator
Solid blade fuses size 00, 1-3 with mechanical indicator type T
Square body fuses size 000 with mechanical indicator type T
Square body fuses size 00 with mechanical indicator type T
Square body fuses size 1* with mechanical indicator type T

CB170H0238
CB170H0238
CB170H0238
CB170H0237
CB170H0237

CB170H0236
CB170H0236
CB170H0236
CB170H0235
CB170H0235

45
45
45
45
45

1
1
1
1
1

CB170H0069
CB170H0235
CB170H0069
CB170H0235
CB170H0069

13
45
13
45
13

1
1
1
1
1

CB170H0235
CB170H0069
CB170H0069

45
13
13

1
1
1

Square body fuses size 1* with mechanical indicator type K


Square body fuses size 1 with mechanical indicator type T
Square body fuses size 1 with mechanical indicator type K
Square body fuses size 2 with mechanical indicator type T
Square body fuses size 2 with mechanical indicator type K

CB170H0237
CB170H0237

Square body fuses size 3 with mechanical indicator type T


Square body fuses size 3 with mechanical indicator type K
Square body fuses size 4 with mechanical indicator type K

CB170H0237

Trip indicators and microswitches for BS88 cylindrical fuses with contact blade
Technical data
Some fuses can be equipped with external mechanical trip indicator.
The trip indicator is mounted parallel with the fuse or can be mounted
separately between fuse clips.
The trip indicator can be equipped with a microswitch for remote fuse
trip indication.

Catalogue numbers - Trip indicators for BS88 cylindrical fuses with contact blade, microswitches
Fuse type

Catalogue number

Weight Packing
each, g size

Trip indicator for fuses type ET, EET, FE, FEE


Trip indicator for fuses type LET
Trip indicator for fuses type FM, FMM
Trip indicator for fuses type LMT, LMMT

CBEC-600
CBEC-250
CBMC-600
CBMC-250

25
25
25
25

1
1
1
1

23
23

1
1

Microswicth type MAI, 250 VAC, 2 A, NO-NC contact, 2,8 mm quick connector CBMAI
Microswicth type MBI, 250 VAC, 2 A, NO-NC contact, 2,8 mm quick connector CBMBI

Schematic diagram - Microswitches


Microswitch for type T/K/D indicators - fuse operational
2
4

30

Microswitch type MAI/MBI - fuse operational


NO

NO

NC

NC

Microswitch type MAI

www.chscontrols.se

Microswitch type MBI

Cooper Bussmann
High Speed Fuses - IEC standard
Off-load fuse disconnectors for cylindrical fuses
Technical data
Material
Rated voltage, Un
Terminal type
Ingress protection, IEC 60529
Standards

Polyester, UL 94V0
IEC 690 V/1000 VDC see catalogue numbers
UL 600 V/1000 VDC see catalogue numbers
Box terminal, see catalogue numbers for wire range
IP 20
IEC 60269, IEC 60947-3

Certificate, approval

CE, cUR file E14853

Catalogue numbers - Off-load fuse disconnector, cylindrical fuses, 35 mm DIN rail mount see note 18, 19, 20, 21, 22
Fuse size/
Off load fuse disconnector version

Rated Terminal
Max
current wire range power
Catalogue number
In, A
mm2
loss/pole, W 1 pole
2 pole

10x38 mm fuse
10x38 mm fuse, lamp indication
10x38 mm fuse, 1000 VDC
10x38 mm fuse, lamp ind., 1000 VDC
14x51 mm fuse

32
32
30
30
50

1-16
1-16
1-16
1-16
2,5-16

3
3
3
3
5

CBCHM1D
CBCHM1DI
CBCHPV1
CBCHPV1I
CBCH141D

CBCHM2D
CBCHM2DI

CBCHM3D
CBCHM3DI

CBCH142D

14x51 mm fuse, lamp indication


14x51 mm fuse, microswitch
22x58 mm fuse
22x58 mm fuse, microswitch

50
50
125
125

2,5-16
2,5-16
2,5-50
2,5-50

5
5
9,5
9,5

CBCH141DI
CBCH141DMS
CBCH221B
CBCH221BMS

CBCH142DI

Weight
g/pole

Packing
size

CBCH143D

50
50
50
50
136

12/6/4
12/6/4
12
12
6/3/2

CBCH143DI
CBCH143DMS
CBCH223B
CBCH223BMS

136
150
242
260

6/3/2
6/-/2
6/3/2
6/-2

3 pole

CBCH222B

Dimensions - Off-load fuse disconnectors for cylindrical fuses, mm


Off-load fuse disconnector for 10x38 mm fuse

Off-load fuse disconnector for 22x58 mm fuse

45

61
83

72

45

127

17,5
35

76

52,5

103

35
70
105

Off-load fuse disconnector for 14x51 mm fuse

45

76
94

103

26,5
53
79,5

Notes
18 Packing size, first value applies for 1 pole, second value for 2 pole and third value for 3 pole fuse disconnectors.
19 Fuse disconnectors for 14x51 mm fuses can also be panel mounted.
20 Rated current for 10x38 mm fuse disconnectors is 32 A according to IEC and 30 A according to UL. Rated current for 14x51 mm fuse disconnectors is 50 A according to
IEC and 40 A according to UL. Rated current for 22x58 mm fuse disconnectors is 125 A according to IEC and 100 A according to UL.
21 Fuse disconnector with indicating light requires at leat 90 V for illumination.
22 Fuse with striker is required to operate the microswitch. The microswitch on 3 pole fuse disconnectors is operated if one or more fuses trip.

www.chscontrols.se

31

Cooper Bussmann
High Speed Fuses - IEC standard
Fuseholders for square body solid blade fuses
Technical data
Material
Rated voltage, Un
Terminal type
Ingress protection, IEC 60529
Standards

Polyamid, UL 94V0, silver plated contact


690 V
Bolt for cable lug
IP 00/20
IEC 60269, DIN 43620

Certificate

CE

Catalogue numbers - Fuseholders, square body solid blade fuses, 35 mm DIN rail or panel mount see note 23, 24
Rated
current
In, A
Terminal

Max
power
Catalogue number
loss/pole, W 1 pole

3 pole

Weight Packing
g/pole size

12
32
45
60

CBTB00-D
CBTB1-D
CBTB2-D
CBTB3-D

150
425
545
725

3/1
3/1
3/1
3/1

Fuseholder, ingress protection IP 20, fuse without microswitch


Fuse size 000/00
160
M8 screw
12

CBTB00-D-IP20

200

Protection kit for fuseholders, IP20, fuse without microswitch


Fuse size 1, for fuseholder CBTB1-D
Fuse size 2, for fuseholder CBTB2-D
Fuse size 3, for fuseholder CBTB3-D

CBFPK1-3P
CBFPK2-3P
CBFPK3-3P

150
150
200

1
1
1

Fuse size

Fuseholders, ingress protection IP 00


Fuse size 000/00
160
Fuse size 1
250
Fuse size 2
400
Fuse size 3
630

M8 screw
M10 screw
M12 screw
M12 screw

CBSB00-D
CBSB1-D
CBSB2-D
CBSB3-D

Dimensions - Fuseholders for square body solid blade fuses, mm

C1
E

Fuse size

C1

C3

000/00
1
2
3

121
200
225
240

146
250
250
270

37
60
60
60

99
192
192
224

78
88
97

85
123
123
143

Notes
23 Packing size, first value applies for 1 pole, second value for 3 pole fuseholders.
24 Contact CHS Controls for IP 20 protection kit for 1 pole fuseholders.

32

C3

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
Fuseholders for square body fuses with DIN80/110 slotted contact blade
Technical data
Material
Rated voltage, Un
Terminal type
Ingress protection, IEC 60529
Standards

Termoplastic
690-1400 V, se catalogue number
Bolt for cable lug
IP 00
IEC 60269, DIN 43653

Certificate

CE

Catalogue numbers - Fuseholders, square body fuses, DIN80/110 slotted contact blade, panel mount see note 24
Rated
current Rated voltage, Un, V
In, A
DIN80
DIN110

Catalogue number
1 pole, DIN80 1 pole, DIN110

Weight
each, g

Packing
size

Fuseholders for square body fuses with DIN80 slotted L contact blade
Skring storlek 000/00
200
690
M8 screw
Skring storlek 000/00
400
1000
M8 screw

CB170H1013
CB170H1007

135
275

3
3

Fuseholders for square body fuses with DIN80/110 slotted contact blade
Skring stolek 1*- 3
630
1000
1400
2xM10 screw
Skring storlek 1*-3
1250
1000
1400
2xM10 screw

CB170H3003
CB170H3004

1035
1300

1
1

Fuse size

Terminal

CB170H3005
CB170H3006

Dimensions - Fuseholders for square body fuses with DIN80/110 slotted contact blade, mm
CB170H1013 fuseholder

CB170H1007 fuseholder

80

80
50

40

25

43

25
110

25
145

CB170H3003/CB170H3005 fuseholder

CB170H3004/CB170H3006 fuseholder
CB170H3004: 80
CBH170M3006: 110

CB170H3003: 80
CB170M3005: 110

77

60

77

60

85

85

Sektion A-A

Sektion A-A

85

85

205

205

Note
25 See page 36 for recommended tightening torque.

www.chscontrols.se

33

Cooper Bussmann
High Speed Fuses - IEC standard
Application guide, high speed fuses for semiconductor protection
The use of semiconductors is steadily increasing in all industries.
Examples of equipment that may contain semiconductors are soft
starters, power converters, adjustable frequency drives, voltage
converters, UPS systems, power supplies and solid state relays.
Since the power semiconductors have low thermal capacity, the
protective device must react very quickly. High speed fuses provide
the best protection.
Fuse construction
The body consists of an insulating material (ceramic or glass-reinforced
plastic) the material has good mechanical properties and resists high
temperatures. The terminals are made of materials with good conductivity
and designed so that they will have good contact surface towards the fuse
holder. The fuse element usually consists of one or more elements. The
shape and dimension are decisive for the characteristics of the fuse. The
melting elements made of silver, alternatively of Silcu (copper with silver in
the melting points) are the most common materials. The fuse body is usually
filled with densely packed quartz sand. The grain size of sand affects the
fuse characteristics. The purpose of the sand is to act as an insulator, to extinguish the arc during short circuit and to absorb the heat energy delivered.
High speed fuses are available in several versions, the most common are
shown in figure 1.

Traditionally, high speed fuses have only been used for short-circuit
protection, another device in the circuit provides overload protection. Class
aR is a partial range protection fuse and is only intended for short circuit
protection. Minimum breaking current is defined by an AA line in the timecurrent curve for the fuse, the fuse will not protect for faults above this line.
Exposing a class aR fuse for overload for a longer time, exceeding the AA
line limitation, increases dramatically the operating temperature, which may
cause damage to the ceramic body as well on the fuseholder. Even if the
fuse survives the overload, it is a high risk that the ceramic body cracks
during a later short circuit.
104
t (s)
103
A-A
102
A-A

101
Class aR
Class gR
Class gG
Class aM

10-1

10-2
Cylindrical fuses 6x32/10x38/14x51/22x58 mm
10-3
Square body solid blade fuses
DIN 43620

10-4
102

Square body fuses with slotted contact blade, bolt fixing


DIN 43653, DIN 80/DIN 110
80/110 mm centre distances

Square body fuses with slotted contact blade, bolt fixing


slotted contact blade according to French standard

Square body fuses with flush end contact


threaded endcap

104

Ip (A)

Fig 2. Time/current curves for square body solid blade fuses size 00, 125 A, from left
class aR, gR, gG and aM. Class aR and aM are fuses for partial protection, minimum
breaking current is defined by the red A-A line, the fuse will not protect for faults
above the line, the curve is dashed.

New technology has made it possible to combine both a very fast shortcircuit protection and overload protection in the same fuse, the restriction of
the AA line disappears, it will be a full range protection fuse, class gR/gS.
In a distribution system a class gR/gS fuse may be sized in the same way
as a class gG fuse. Discrimination against upstream class gG fuse will be
maintained.

Fuse selection
The following information are required to choose the right fuse to protect
semiconductor devices
Rated voltage of the fuse (Un) must be equal or larger than the nominal
voltage of the circuit.
Max current (I) in the circuit during normal conditions.
The energy (I2t) cleared by the fuse during a short circuit must be less
or equal to the withstand energy of the semiconductor, see fig 3. The
energy is stated in A2s.
The breaking capacity of the fuse must be higher than the prospective
circuit short circuit current.
Current/voltage peaks, cyclic loads, temporary overloads etc do also
affect the fuse selection, contact CHS Controls for more information.

Fuses according to BS 88-4


cylindrical fuses with L and T contact blade
square body fuses with L-contact blade

Neozed fuses, D01/D02/D03


Diazed fuses, D I/D II/D III/ D IV/D V

Fig 1. Common types of high speed fuses according to IEC standard

Utilization classes according to IEC 60269


IEC 60269 divides fuses in different utilization classes, the most common are
Class aM, partial range protection, motors, short circuit protection
Class gG, full range protection, cable, line and general protection
Class aR, high speed, partial range protection, short circuit protection
Class gR/gS, high speed full range protection
Class gPV, high speed full range protection for photovoltaic systems

34

103

Note that the internal voltage for certain products, such as the the intermediate section in adjustable frequency drives, may be higher than the supply
voltage. Another aspect to consider is that subsystems may change from
AC to DC voltage, such as the common DC busbar in a regenerative drive
system.

www.chscontrols.se

Cooper Bussmann
High Speed Fuses - IEC standard
I
Possible unrestricted short circuit current
I2t pre-arc
I2t total

tp

tt

Breaking current
Melting time
Total breaking time

In general, fuses that are designed and tested for DC shall be used. Some
applications are simpler, have a low time constant, in these cases, an AC
fuse usually provides sufficient protection. Note that the time constant also
affects the melting time of the fuse compared with published data for AC
circuits. In the time range below 1 s, the fuse becomes slower at higher
time constant, see fig 5. Contact CHS Controls for more information and
application assistance.

Fig 3. Short circuit interrupting. During the pre-arcing time the fuse elements are heated up until they melt, several arcs occur inside the fuse and the short circuit current
begins to be interrupted - the released energy during this stage is called I2t pre-arc.
The arcs inside the fuses are interrupted by the sand and the circuit is interrupted.
The total let-through energy is called I2t total.

Total clearing correction factors

Time/current curve - AC circuit


Time current curve - DC curcuit lower L/R
Time/current curve - DC circuit higher L/R

Melting time

Ic
tp
tt

IC

as L/R and stated in ms. To calculate the time constant of DC circuits, we


need information on the short circuit current, inductance and resistance in
the short circuit point. The latter are difficult to measure/calculate and vary
depending of environmental factors, such as temperature.

The total clearing, total I2t is stated at a certain voltage, usually at the rated
voltage, Un. For other operating voltages, correction factors can be used
to calculate a new I2t for a fuse. With the help of a curve, a factor for the
current operating voltage can be found, see fig 4.

Current

Fig 5. The DC circuit time constant (L/R) influences the fuse melting time in the range
below 1 s compared to AC circuits.
1,4

Photovoltaic systems protection

1,2

A solar cell/photovoltaic cell converts light into DC. Photovoltaic (PV)


systems present special cases for fuse protection. A trend in recent years is
that the voltage increases up to 1000 VDC for larger installations.

1,0
0,9
0,8
0,7

A PV panel is a sealed unit consisting of a number of interconnected solar/


photovoltaic cells. PV panels are connected in series into a string in order
to generate the required voltage. A number of strings can then be connected in parallel until the desired effect is achieved.

0,6
0.5
0,4

Eg
0,3
200

300

400

500

600

700

Fig 4. I2t correction factors - cylindrical fuses 22x58 mm type CBFWP-_22F.

Normal recommendation is that the fuses are installed on both sides of


each string, and on both sides of the parallel connected strings, when unearthed systems are common, see fig 6.

Example: I2t total for 40 A (690 V) = 750 A2s. Calculated value for I2t total at 400 VAC
750*0,57 = 428 A2s, see red line.

Temperature
Fuses must be cooled. The normal cooling method is convection from the
terminals and the fuse body. A fuse may be de-rated for environments with
higher ambient temperature than 40C. It is not uncommon that larger fuses
are forced cooled to avoid de-rating. Contact CHS Controls for conversion
factors.
High speed fuses usually emit more heat, have higher power losses,
compared with fuses for cable or motor protection. This must be considered
when selecting a fuse disconnector/fuseholder/fuse disconnect switch.
Fuse disconnectors and fuseholders in the catalogue are designed for high
speed fuses. Contact CHS Controls for the appropriate fuse disconnect
switches.

DC circuits
Compared to AC circuits, the absence of natural voltage zero in a DC
circuit makes it more difficult for a fuse to interrupt the current at fault. It is
especially notable in circuits with high time constant. The time constant,
which denotes the ratio of inductance/resistance in the circuit, is referred to

+ 1000 VDC

Fig 6. Typical design of a photovoltaic systems. The fuses are located on both sides
of the string and on both sides of the parallel connected strings.

The fuses should be able to interrupt the low-fault currents resulting from
the failure of the solar cells while they cope with high fault currents that may
result from failure of an inverter. In addition, the fuse is exposed to cyclic
loading, depending on the temperature of the solar module. Appropriate
fuses meet utilization class gPV according to IEC 60269-6. Contact CHS
Controls for additional information.

www.chscontrols.se

35

Cooper Bussmann
High Speed Fuses - IEC standard
Installation guide
High speed fuses usually emit more heat, have higher power losses
compared with fuses for cable and motor protection. This must be
be considered during installation.
High speed fused with flush end contact
Fuses with flush end contact are normally connected direct to busbars. For
reliable operation, it is important to have proper contact pressure. Cooper
Bussmann recommends use of screw-in studs according to DIN 913/ISO
4026. Attach the stud carefully in the fuse with a torque of 5-8 Nm, use
a torque wrench. Attach the fuse to the busbar, see fig 7, with the nut,
tightening torque according to table. Make sure the busbar is aligned with
the fuse.

High speed fuses, DIN80L/DIN80/DIN110 contact blade


When installing against busbars, use the largest possible bolts, screws,
washers and nuts, tightening torque according to the manufacturers
recommendations. For installation in the Cooper Bussmann fuseholders,
tightening torque according to table. Contact CHS Controls for fuseholders
for BS 88 fuses.

Other types of high speed fuses


Cylindrical fuses, NH fuses and Neozed/Diazed fuses can be installed
in standard fuseholders/fuse disconnectors/fuse disconnect switches,
provided that the fuse power losses do not exceed what the fuseholder/fuse
disconnector/fuse disconnect switch can handle.

Recommended tightening torque


F

F: Establish balance

OK

OK

Fuse
size

Threaded hole

Tightening torque nut, Nm


Greased thread *) Ungreased thread

Size 00
Size 1*
Size 1
Size 2
Size 3

M8, depth 6 mm
M8, depth 5 mm
M8, depth 8 mm
M10, depth 10 mm
M12, depth 10 mm

10
10
10
20
40

20
20
20
40
50

Size 4

4xM10, depth 10 mm 20

40

F
Fig 7. Installation of fuses with fush-end contact and DIN80L/DIN80/DIN110 slotted
contact blade.
2

The minimum current density of the busbar is 1,3 A/mm . If the current
density is lower, the fuse must be de-rated, contact CHS Controls for correction factors.

Fuseholder

Tightening torque nut, Nm


Greased thread *)

CB170H1007 - CB 170H1013
CB170H3003 - CB170H3006

12
20

n!

Al

nglig - Alltid
pp
tillg
e
tl id

en

www.chscontrols.se

Alw

CHS Controls AB
Florettgatan 33
SE-254 67 Helsingborg, Sweden
Phone +46 42 386100, fax +46 42 386129
SMS +46 155 768 086112
chs@chscontrols.se
www.chscontrols.se

ay
op
s av
ailable - Always

Catalogue PM1065Ea, January 2011 CHS Controls AB