1.0 GENERAL REQ!REMEN"S Vendor to note that technical details given in this specification covers the broad requirement. Vendor shall include & specify all items & details to ensure performance of the unit as per desired specifications. Vendor must select filter area to permit filtration rate & provide adequate dirt holding capacity as specified below. *Marked Items to be specified by vendor #.0 Specification$ 2. !"# $o. % &'( )*2 2.2 +,"$!I!- % 2.. M./.&. housing0filter element % 11(.*20* 2.2 !ype of filter % * 2.2 3$4 &/$$3&!I/$ process0utility fluid % "1" )*5 '6"$#3 3$4 2.) !-73 /' &6/1,83 '/8 &"1I$# % '6"$#34 ! & # type with eye bolts %.0 &R'(ESS )A"A .. 'luid handled % 4istilled methanol at 8! ..2 1pecific #ravity 9 at operating !emperature: % *.; ... Viscosity9at operating !emperature: % *. &p ..2 'low rate % ) m.0hr ..) "llowable pressure drop % *.) bar ..< 7article si=e retention % 2 microns 9absolute at ** > efficiency: ..? 3ffective filtration area0 rating % * m 2 0 * microns ..; &ake !hickness0loading % * mm 9&onsider kg dirt loading: ..@ 'low 4irection % /utside to Inside *.0 "E(+N!(AL &ARAME"ERS 2. 4esign 'ilter Vessel % "s per "1M3 1ec. VIII 4iv I 2.2 4esign 7ressure 91hell: % 2.) bar g 2.. 4esign 7ressure 9Aacket: % $" 2.2 /perating 7ressure 91hell: % 2.* bar g 2.) /perating 7ressure9Aacket: % $" 2.< 4esign !emperature91hell: % )* deg & 2.? /perating !emperature91hell: % .* deg & 2.; Aacket side utility % $" 2.@ 'ilter housing diameter % *mm 2. * 'iltration "rea % *m2 2.
$o. 'ilter elements % * $os
2. 2 'ilter element 6ength % *mm 2. . &ake Bolding &apacity % * litres at *mm cake thk 2. 2 'ilter element 4imensions % *mm dia C *mm long 2. ) $umber and 7itch of cartridges % *mm centre to centre 2. < !ype of filter element % 4isposable 2. ? Dackwashing 7ressure reqd. % $" 2. ; !ype of &losure for casing % 3ye Dolt 2. @ 1ealing of cartridge with housing % #asket sealing preferred over o(ring based on our eCperience ,.0 SRFA(E F!N!S+ ). I$!38$"6 1.1. 7/8!I/$ % Duffed to ;* grit ).2 3E!38$"6 1.1. 7/8!I/$ % "cid cleaned ).. 3E!38$"6 &.1. 7/8!I/$ % !wo coats of 3poCy red oCide primer F epoCy grey -.0 !NSLA"!'N % $ot in scope of vendor ..0 S&&'R"S % * /.0 GAS0E" % * 1.0 N"S 2 3'L"S 2 (4(LAM&S % 3ye Dolts 11. 0 !NS&E("!'N Material shall be inspected by "!,6. Vendor to give material test certificates in 2 copies. 1#. 0 &ERF'RMAN(E GARAN"EE 3ntire equipment shall be tested for performance continuously for 22 hours and guarantee figures shall be established. !he unit shall be guaranteed against workmanship for a period of ; months from the date of delivery or 2 months from the date of commissioning whichever is earlier. 1%. 0 )RA5!NGS Vendor to send 2 copies of drawings within one week for approval.